7677 - Tahoma Blvd Apts - Bldg 2 - Sprinkler PlanBATT TYPE INSULATION TENTED OVER ALL ATTIC SPRINKLER PIPE (BY OTHERS)9'-0"9'-0"FLOOR LINE R-10 RIGID INSUL TOP OF SLAB 12 SAND AND GRAVEL BASE. 2 X 4 STUDS AT 16" O.C. WITH 5/8" GYP. BD. MANUF. TRUSSES MANUF. TRUSSES (WARM SIDE) GABLE END VENT 2X6 OVERFRAME 4 TOP PLATE FLOOR LINE RUN 24" MIN BELOW 4" CONC. SLAB W/ 6 MIL. VAPOR RUN 24" MIN BELOW INTERIOR WALLS- GABLE-END PER TRUSS MANUF 24" O.C. MAX VAPOR BARRIER @ 24" O.C. 12 TOP PLATE SEE STRUCTURAL TOP OF SLAB 4 BARRIER OVER 4" COMPACT R-10 RIGID INSUL UNLESS OTHERWISE NOTED. 24" O.C. MAX 2 X 6 STUDS AT 16" O.C. @ RESTROOMS SEE EXT ELEVATIONS GIRDER TRUSS R-49 INSULATION W/ CONT. UNIT B KITCHEN LIVING LIVING KITCHEN LIVINGKITCHEN UNIT BUNIT B KITCHEN LIVING UNIT B 32280.4' 22 (UNDERGROUND)(UNDERGROUND) FP11 3-BED UNIT UNIT A *1A TYPE 'A' UNIT 2-BED UNIT UNIT B *1C TYPE 'A' UNIT 1-BED UNIT UNIT C *1E TYPE 'A' UNIT 2-BED UNIT UNIT D *1G TYPE 'B' UNIT 3-BED UNIT UNIT A *1B TYPE 'B' UNIT 2-BED UNIT UNIT B *1D TYPE 'B' UNIT 1-BED UNIT UNIT C *1F TYPE 'B' UNIT 2-BED UNIT UNIT D *1H TYPE 'B' UNIT UP UP UP UP W D W D D W W W W D D D D W D W 2 -UP2 -DN2 -DN212 22 -DN2 -DN2111 -UP1 -UP207 206 209 210 223 208 205 11¼1¼1 1 1 11 1112 1 1¼111 1 1 11 11 11 1¼1¼1111 1 1 1 1 1¼1¼111 11¼11¼1 1 1 11 1¼1¼ 1½1¼11 1 1 11 1 11¼1 1¼11¼1 1 1 1 1 1 211¼1¼1 1 11 1 111¼1 1¼ 1 1 11 1¼111¼111 11 1 11 1¼1¼11 1¼111 11 1 1 1 122 1¼1¼11¼1¼1¼1¼1¼1¼1¼1¼1¼1¼222 1¼1¼1¼11¼1¼11¼1¼ 1¼1¼1¼1111¼1¼11¼1¼11¼1¼ 2 21¼1¼1¼1¼1¼1¼11¼111¼1¼ 1¼ 1¼21 1 1 11¼111 1¼1¼1 11¼1¼1¼1¼1¼1¼1¼1¼ -UP1¼ -UP1¼ -UP1¼ -UP1¼ -UPBEDROOMMSTR 9'-0" CLG 9'-0" CLG LIVING ROOM KITCHEN 9'-0" CLGBEDROOM 39'-0" CLGBEDROOM 2 <55FT²BATHBATH UTILITY 9'-0" CLG 9'-0" CLG BATH 9'-0" CLG 9'-0" CLG UTILITY <55FT² BEDROOM 3 BATH BEDROOM 2 MSTRBEDROOM KITCHENLIVING ROOM 9'-0" CLG LIVING ROOM KITCHEN UTILITY BATH<55FT² BEDROOM 29'-0" CLG 9'-0" CLG 9'-0" CLG BATH LIVING ROOM BEDROOM 2 BEDROOM UTILITY 9'-0" CLG MSTR <55FT² KITCHEN BATH BATH CONC.PATIO PATIOCONC. CONC.PATIO CONC.PATIO CONC.PATIO LIVING ROOM 9'-0" CLG9'-0" CLGBEDROOM BATH KITCHEN BEDROOM LIVING ROOM KITCHEN 9'-0" CLG BATH 9'-0" CLG PATIOCONC. CONC.PATIO 9'-0" CLGBEDROOM 3 8'-0" CLG WIC 9'-0" CLG BEDROOMMSTR 9'-0" CLG BEDROOMMSTR LIVING ROOM 9'-0" CLG KITCHEN UTILITY BATH<55FT²BATH BATH UTILITY LIVING ROOM 9'-0" CLG BEDROOM 3 <55FT² KITCHEN MSTR WIC 9'-0" CLG BATH 9'-0" CLG BEDROOM 8'-0" CLGPATIOCONC. BEAM BEAM BEAM BEAM BEAMBEAM BEAM BEAM BEAM BEAM BEAM BEAM BEAMBEAM BEAM BEAM BEAM BEAM BEAM BEAM BEAM BEAM 1¼ -UP32280.4'GRAVEL91' PVC211' PVC6"6"61' PVC2"TAHOMA BOULEVARD SE105' DI 52 30' DI 52 33' PVC 1 0 5 ' D I 5 2 27' DI 526' DI 5256' PVC10' PVC 178' PVC52' PVC224' PVC 127' PVC32' PVC2"7' PVC 2" 10' PVC 6"6" 8 "6"6" 6"6"6" 2"2"2"30' PVC9' PVC 2"2"2" 6"12"1 2 3 4 5 6 7 8 2" WATER SUPPLY LINE2" DERINGER 30 (DCDA)1 -2 -3 -4 -5 -6 - 8 - WATER FLOW ALARM SWITCH WIRED TO ALARM BELL 1" VALVE FOR DRAIN1" DRAIN LINE PIPED TO EXTERIOR OF BUILDING WATER PRESSURE GAUGE 6" ALARM BELL INSTALLED ON EXTERIOR OF BUILDING RISER LEGEND 2"7 -UPRIGHT SPRINKLER TO PROTECT RISER ALL CONTROL VALVE HANDLES TO BE REMOVED1 - RISER NOTES AND PLACED IN HEAD BOX AT TIME OF FINALWIRING OF FLOW SWITCH AND BELL TO BE BY OTHERS2 -2" SUPPLY LINE TO BE PROVIDED BY OTHERS3 - 1" MALE ADAPTER 11 10 9 -2" CHECK VALVE10 -1/2" AUTOMATIC BALL DRIP11 - 9 2½" SINGLE OUTLET OPEN SNOOT FDC WITH BREAKAWAY CAP 2"2"2½" X 0-8 GALVANIZED NIPPLE 2½" SINGLE INLET FDCWITH BREAK AWAY CAP 2" CHECK VALVE 6" 120VAC ALARM BELL TO BE CONNECTED TO (INSTALLATION AND 1"WIRING BY OTHERS) WATER FLOW SWITCH. 2" 2" FEMALE ADAPTER GRADEGRADE2"2"2"2"2" MALE ADAPTER½" X 0-6 GALV NIPPLE½" GALVANIZED WALL PLATE ½" GALVANIZED COUPLING ½" GALVANIZED 45° 1 X ½" RC ½" AUTOMATIC BALL DRIP 3'-0"FSI START SCOPE OF WORK: INSTALL NEW NFPA 13R FIRE SPRINKLER SYSTEM THROUGHOUT NEW RESIDENCE PER NFPA 13R (2019) GENERAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE OWNER TO MAINTAIN THE INTEGRITY OF THE SPRINKLER SYSTEM. 2. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 3. ALL SYSTEM PIPING SHALL BE TESTED AT STATIC PRESSURE PER NFPA 13D. 4. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13D (2019). 5. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 6. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 7. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. DESIGN NOTES: 1. RISER ASSEMBLY LOCATED IN ATTACHED RISER ROOM (FSI START POINT). 2. SYSTEM TO BE DESIGNED IN ACCORDANCE WITH NFPA #13R MULTI FAMILY RESIDENCE. 3. PLAN SUBMITTAL TO AND APPROVAL BY CITY OF YELM. 4. MATERIALS PER NFPA #13R STANDARDS AS SELECTED BY FSI. 5. TESTING PER NFPA #13R AND CITY OF YELM. 6. TYPICAL HANGERS TO BE TOLCO FIG. 24, 28M & 29 UNLESS NOTED OTHERWISE FIELD NOTES: 1. ALL NEW PIPE IS TO BE CPVC. 2. ALL NEW FITTINGS ARE TO BE CPVC. 3. DESIGN CRITERIA TO BE BASED ON NFPA 13R: A. SPRINKLER SPACING NOT TO EXCEED (16' X 16') OR (8') OFF OF WALLS MAXIMUM. B. MINIMUM PRESSURE AND FLOW FOR SPRINKLERS SPACED 16' X 16' = 13 GPM @ 7 PSI. NTS HANGER TYPE CP TOLCO FIG. #29TOLCO FIG. #24 NTS HANGER TYPE CP TOLCO FIG. #28M NTS HANGER TYPE CP ATTIC INSULATION (BY OTHERS). BOTTOM CHORD OF TRUSS USE BATT TYPE INSULATION GWB CEILING (BY OTHERS). USE BATT TYPE TENT FIRE SPRINKER PIPEBEFORE INSULATING ATTIC WET PIPE FREEZE CPVC FIRE SPRINKLER PIPE FOR TENTING INSULATION FOR TENTING. NTS PROTECTION DETAIL 1 FP1 C. PEND1554.9RA1664½"VK467½"CHQR½"1"4.9BRVIKINGBRCHQRUPRIGHTQR1"QRCH155QRVIKNGVK494DRY HSWVK494200200CHRELIABLEVIKINGWHDRY ECSWBR1555.6124N/A24155VK178WHVIKING4.9C. PEND155.6REVISIONS: REV# DATE: SCALE: DATE BY HANGER LEGEND: DESCRIPTION AHJ: CONTRACT WITH: SHEET NUMBER: REVIEWED BY: DRAWN BY: JOB NUMBER: DRAWING SYMBOLS: T D TOP BEAM CLAMP W/ STRAP H X - S SAMMY SUPER SCREW (GST20/30) TRAPEZE CP CPVC HANGER HILTI KWIK HUS-EZ SD SAMMY SIDEWINDER (SWDR 516)TOTAL THIS PROJECT =THRDTYPEMFR264ESCTEMPRESPSYMQTYFINISHKSINSPRINKLER LEGEND(SEE CHART) - ELEVATION - CENTERLINE A.1 - HYDRAULIC NODE - WELDED - FLEXIBLE GROOVED FFAFF CC DATUMDATUM 1 COUPLING - BRANCHLINE - ELEVATION10'-10"- SEISMIC BRACE LL TSTS DECK PIPE TAG DECK & LENGTH CUT #1 NUMBER - CENTERLINE 9'-0- PIPE HANGER - PIPE SIZE - RIGID GROOVED CAC LL0'-10"0'-10"OF PIPE TOOF PIPE TO COUPLING AS NOTED CCS 05/17/22 7677 CITY OF YELM JNZ FP1 OF 2 YELM, WA 9859715035 BERRY VALLEY ROAD SETAHOMA BLVD APARTMENTSPUYALLUP, WA 98371 SCHUUR BROS INC GC: JERRY SCHUUR - 253-651-3786 PO BOX 597 1524 45TH STREET EAST, SUITE 102 SUMNER, WA 98390 (253) 826-0099WWW.FIRESPRINKLERSINC.COM BUILDING SECTION A SCALE: NTS SCALE: 1/8" = 1'-0"NORTHVICINITY MAPMAIN FLOOR - SPRINKLER PIPING PLAN NORTHSCALE: NTS SCALE: NTSNORTH BUILDING 2 SITE PLAN SCALE: NTS RISER DETAIL HYDRAULICALLY DESIGNED GPM FLOWING: 54 1130 56 HYDRAULICALLY DESIGNED DATE & TIME: THIS SYSTEM IS NOT RESIDUAL: - THIS SYSTEM IS STATIC: - FLOW TEST - HYDRAULIC DESIGN INFO "DOUBLE OFFSET" HANGER & RESTRAINER HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE HARDENED HEX HEAD SELF THREADING SCREWIS FURNISHED WITH THE HANGER AND IS THEMINIMUM FASTENER SIZE ACCEPTABLE CPVC DOUBLE FASTENER STRAP TYPE HANGER "OFFSET" HANGER & RESTRAINER HARDENED HEX HEAD SELF THREADING SCREWIS FURNISHED WITH THE HANGER AND IS THEMINIMUM FASTENER SIZE ACCEPTABLE FOR CPVC AND IPS PIPE WA CL# FIRESI*988RJ X 6" PVC SUPPLY EXISTING 8" WATER MAIN OF FLOW TEST) FIRE HYDRANT (EFFECTIVE POINT GATE VALVE (BY OTHERS) FIRE HYDRANT (BY OTHERS) DCDA LOCATED INSIDE RISER ROOM 2½" SINGLE SNOOT WALL FDC FIRE SPRINKLER RISER ROOM WITH KNOX BOX (BY OTHERS) +/- 120' OF 2" SUPPLY PIPE (BY OTHERS) 214 213 BLDG 3BLDG 2THIS PERMIT BLDG 4 BLDG 1 217 216 2 215 212 211 212 SITE Christopher Cameron Smith 0087-0618-C Level 3 Fire Sprinklers Incorporated FIRESI*988RJ 05/23/2022 3-BED UNIT UNIT 2A 2-BED UNIT UNIT 2C 1-BED UNIT UNIT 2E 3-BED UNIT UNIT 2B 2-BED UNIT UNIT 2D 1-BED UNIT UNIT 2F 2-BED UNIT UNIT 2H 2-BED UNIT UNIT 2G 32280.4' D W D W DW W D W UP UP W D W D UP D DW DNUP DNUP UPDN UPDN1¼ -DN1¼ -DN1¼ -UP/DN1¼ -UP/DN1¼ -UP/DN1 -UP1 -UP221 204 222 203 1 111¼1¼1111¼ 1 1 1 1¼1 1 1 1¼1 1¼1 11 1¼1 11 1111 1 1¼1¼1¼1¼1¼1¼1¼1¼1¼1¼1¼1¼ 1¼1¼1¼1¼1¼1¼ 1¼ 1 1¼1 1¼ 1 1¼111111111¼11¼1 11¼1 1 1 1 1 1¼1¼1 1¼1 1 11 1¼1111¼1¼11¼1¼11¼1 11¼1¼ 1¼ 1 11 1¼ 1 11 1 11111 1 11¼1¼1¼11¼1¼11 1¼ 1 1¼11¼1 1¼11¼1 1¼ 1 11¼1¼1¼11 1¼1¼1¼1 1111 1 11 1 11¼1¼1¼1¼1¼11 1¼1111 1 1 1 1 1 11 1¼1¼11 1 1 1¼ 1¼1¼ -UP1¼ -UP/DN9'-0" CLG BEDROOM BEDROOM 2 9'-0" CLG BEDROOM BATH 9'-0" CLG WIC BEDROOM 9'-0" CLG 9'-0" CLG <55FT² LIVING ROOM 9'-0" CLG BEDROOM LIVING ROOM PATIO BATH BATH CONC. LIVING ROOM UTILITY PATIO MSTR LIVING ROOM <55FT² 9'-0" CLG KITCHEN BEDROOM 3 BEDROOM CONC. KITCHEN BEDROOM 2 9'-0" CLG 9'-0" CLG BATH 8'-0" CLG KITCHEN BEDROOM 2 9'-0" CLG BATH KITCHEN 9'-0" CLG KITCHEN MSTR 9'-0" CLG BEDROOM 2 9'-0" CLG BEDROOM 3 PATIO BEDROOM UTILITY CONC. UTILITY <55FT² CONC.9'-0" CLG KITCHEN CONC. LIVING ROOM MSTR UTILITY WIC 9'-0" CLG 9'-0" CLG BATH 9'-0" CLG CONC. <55FT² UTILITY BATH UTILITY <55FT² BEDROOM LIVING ROOM LIVING ROOM BEDROOM 3 9'-0" CLG BATH 9'-0" CLG LIVING ROOM KITCHEN 9'-0" CLG MSTR MSTR 9'-0" CLG CONC. <55FT² BATH PATIO KITCHEN BATHPATIO BATH 9'-0" CLG BEDROOM 3 BEDROOM 9'-0" CLG 8'-0" CLG BATH PATIO BATH 9'-0" CLG PATIO MSTR BATH PATIOCONC. BEAMBEAM BEAM BEAM BEAMBEAM BEAM BEAM BEAM BEAM BEAM BEAMBEAM BEAMBEAM BEAM BEAM BEAM BEAM BEAM BEAM BEAM1¼ -UP1¼ -DN3-BED UNIT UNIT 3A 2-BED UNIT UNIT 3C 1-BED UNIT UNIT 3E 2-BED UNIT UNIT 3G 3-BED UNIT UNIT 3B 2-BED UNIT UNIT 3D 1-BED UNIT UNIT 3F 2-BED UNIT UNIT 3H 32280.4' WD D W UP D W D D UP W D D W UP D W W W DN DN DN DN1¼ -DN1¼ -DN1¼ -DN1¼ -DN1¼ -DN2001 2004 2003 2002 220 201 225 224 219 202 1¼1 1 1 1¼1¼1111 1 1¼ 1 11 1 1 11¼11¼1¼1¼1¼1¼11111¼1 1 11¼1¼1¼1¼ 1¼1¼1¼1¼1¼1¼1¼1¼1¼1¼1¼1¼ 1¼ 1 111 11 111 1 1 1 1¼1 1¼1¼1¼1¼ 1¼ 1¼ 1¼ 1 11¼1¼1¼1¼1 1¼1¼111¼1¼1¼1¼1¼1¼1¼11 1¼ 1 11 1¼1¼ 1 1 1¼ 1 11¼1¼1¼1 1 1¼1 11 1¼111¼ 1¼ 1 1 1 1 111 1 1 1 111111¼1¼ 1¼1¼ 1 1 1 1 1¼1¼11¼11¼ 1¼ 1 1 1 1 1¼1¼1¼1¼1¼1¼1¼111¼1¼1¼1¼1¼1¼1¼ 1¼1¼1¼11¼BATH 9'-0" CLG CONC. 9'-0" CLG BEDROOM 9'-0" CLG CONC. KITCHEN CONC.LIVING ROOM <55FT² CONC. BATH PATIO KITCHEN BEDROOM 2 <55FT² BATH BEDROOM LIVING ROOM BATH BATH KITCHEN MSTR 9'-0" CLG BATH KITCHEN 8'-0" CLG BEDROOM 3 MSTR PATIO KITCHEN PATIO PATIO <55FT² CONC. CONC. UTILITY PATIO MSTR BEDROOM 3 9'-0" CLG 9'-0" CLG 9'-0" CLG 9'-0" CLG WIC LIVING ROOMBEDROOM UTILITY 8'-0" CLG BEDROOM PATIO <55FT² 9'-0" CLG PATIO BATH CONC. WIC 9'-0" CLG LIVING ROOM BATH 9'-0" CLG UTILITY BATH UTILITY BATH 9'-0" CLG BEDROOM LIVING ROOM 9'-0" CLG LIVING ROOM 9'-0" CLG MSTR 9'-0" CLG KITCHEN BEDROOM BEDROOM 2 9'-0" CLG MSTR WIC 9'-0" CLG <55FT²BATH MSTR BATH 8'-0" CLG BEDROOM 3 UTILITY <55FT² BEDROOM 3 BEDROOM LIVING ROOM UTILITY KITCHEN BATH 9'-0" CLG BATH KITCHEN BEDROOM 8'-0" CLG 9'-0" CLG 9'-0" CLG LIVING ROOM 9'-0" CLG WIC 9'-0" CLG PATIOCONC.C. PEND155RA1664½"½"CHQR½"1"4.9BRBRCHQRQR1"QRCH155QRDRY HSW5.6-200CHRELIABLEWHDRY ECSWBR1555.6--N/A-155WH4.9C. PEND-VK494VIKINGVIKINGVK494VIKNGVK178UPRIGHTVIKINGVK4674.9REVISIONS: REV# DATE: SCALE: DATE BY HANGER LEGEND: DESCRIPTION AHJ: CONTRACT WITH: SHEET NUMBER: REVIEWED BY: DRAWN BY: JOB NUMBER: DRAWING SYMBOLS: T D TOP BEAM CLAMP W/ STRAP H X - S SAMMY SUPER SCREW (GST20/30) TRAPEZE CP CPVC HANGER HILTI KWIK HUS-EZ SD SAMMY SIDEWINDER (SWDR 516)THRDTYPEMFRESCTEMPRESPSYMQTYFINISHKSINSPRINKLER LEGEND(SEE CHART) - ELEVATION - CENTERLINE A.1 - HYDRAULIC NODE - WELDED - FLEXIBLE GROOVED FFAFF CC DATUMDATUM 1 COUPLING - BRANCHLINE - ELEVATION10'-10"- SEISMIC BRACE LL TSTS DECK PIPE TAG DECK & LENGTH CUT #1 NUMBER - CENTERLINE 9'-0- PIPE HANGER - PIPE SIZE - RIGID GROOVED CAC LL0'-10"0'-10"OF PIPE TOOF PIPE TO COUPLING AS NOTED CCS 05/17/22 7677 CITY OF YELM JNZ FP2 OF 2 YELM, WA 9859715035 BERRY VALLEY ROAD SETAHOMA BLVD APARTMENTSPUYALLUP, WA 98371 SCHUUR BROS INC GC: JERRY SCHUUR - 253-651-3786 PO BOX 597 1524 45TH STREET EAST, SUITE 102 SUMNER, WA 98390 (253) 826-0099WWW.FIRESPRINKLERSINC.COM NORTHSCALE: 1/8" = 1'-0" SECOND LEVEL - SPRINKLER PIPING PLAN SCALE: 1/8" = 1'-0" THIRD LEVEL - SPRINKLER PIPING PLAN NORTHHYDRAULICALLY DESIGNED GPM FLOWING: 54 1130 56 HYDRAULICALLY DESIGNED DATE & TIME: THIS SYSTEM IS NOT RESIDUAL: - THIS SYSTEM IS STATIC: - FLOW TEST - HYDRAULIC DESIGN INFO16' X 16' RESIDUAL: HYDRAULIC DESIGN INFO 53.00 GPM @ 50.442 PSI THIS AREA HAS BEEN HYDRAULICALLY CALCULATEDTO DELIVER A RESIDENTIAL COVERAGE (NFPA 13D) OF: REMOTE AREA #2 MAX AREA/HEAD: SYSTEM DEMAND: DENSITY: K-FACTOR: HYDRAULICALLY DESIGNED THIS SYSTEM IS 54 HYDRAULICALLY DESIGNED AREA 2 56 .05 GPM / SQ FT -DATE & TIME: 4.9K 13 GPM @ 7.0 PSI USING 16' X 16' HEAD SPACING GPM FLOWING: - SYSTEM DESIGN - - FLOW TEST - REMOTE AREA: THIS SYSTEM IS NOT STATIC: 1130 WA CL# FIRESI*988RJ X Christopher Cameron Smith 0087-0618-C Level 3 Fire Sprinklers Incorporated FIRESI*988RJ 05/23/2022