7677 - Tahoma Blvd Apts - Bldg 4 - Sprinkler PlanBATT TYPE INSULATION TENTED OVER ALL ATTIC SPRINKLER PIPE (BY OTHERS)9'-0"9'-0"FLOOR LINE R-10 RIGID INSUL TOP OF SLAB 12 SAND AND GRAVEL BASE. 2 X 4 STUDS AT 16" O.C. WITH 5/8" GYP. BD. MANUF. TRUSSES MANUF. TRUSSES (WARM SIDE) GABLE END VENT 2X6 OVERFRAME 4 TOP PLATE FLOOR LINE RUN 24" MIN BELOW 4" CONC. SLAB W/ 6 MIL. VAPOR RUN 24" MIN BELOW INTERIOR WALLS- GABLE-END PER TRUSS MANUF 24" O.C. MAX VAPOR BARRIER @ 24" O.C. 12 TOP PLATE SEE STRUCTURAL TOP OF SLAB 4 BARRIER OVER 4" COMPACT R-10 RIGID INSUL UNLESS OTHERWISE NOTED. 24" O.C. MAX 2 X 6 STUDS AT 16" O.C. @ RESTROOMS SEE EXT ELEVATIONS GIRDER TRUSS R-49 INSULATION W/ CONT. UNIT B KITCHEN LIVING LIVING KITCHEN LIVINGKITCHEN UNIT BUNIT B KITCHEN LIVING UNIT B 32280.4' 22 (UNDERGROUND)(UNDERGROUND)1¼ -UP1FP1 DD 2-BED UNIT UNIT C *1F TYPE 'B' UNIT 2-BED UNIT UNIT D *1G TYPE 'A' UNIT 3-BED UNIT UNIT A *1A TYPE 'A' UNIT D 2-BED UNIT UNIT B *1D TYPE 'B' UNIT 2-BED UNIT UNIT B *1E TYPE 'B' UNIT 2-BED UNIT UNIT D *1H TYPE 'B' UNIT 3-BED UNIT UNIT A *1B TYPE 'B' UNIT 2-BED UNIT UNIT B *1C TYPE 'A' UNIT D W D UP W W D W D UP UP DW WW W UP 2 -DN2 -DN2 -DN412 22 2 -DN411 2 -DN408 422 405 406 410 407 409 11 1 11¼111111 11¼11 11¼1 111¼1¼1¼1¼11 1 1¼1¼1¼1 1¼1¼1 1¼11¼1¼11¼ 1 1 1¼111¼1¼11¼1 11¼1¼1¼1¼ 1¼1¼1 1¼1 1¼111 11 1 1 1¼1¼1¼1¼1 11 1 11 1 111¼ 1 1 11¼ 1 1 1¼11 11¼ 1¼ 1 1¼1¼ 1 1 11 1¼1 1¼ 1¼ 1 1 1¼1¼11¼ 1 11¼ 1¼11 1 11 1¼1¼11 1¼1¼11 11¼11¼ 1¼1¼1¼111 1¼11¼ 1¼ 1 1¼ 1 11 111¼1 1 1 1 1¼ 1¼ 1 211¼1 1 11 11¼ 1 1¼ 1¼ 1¼11 1¼ 1 1¼11¼11¼1¼11¼1 1¼1¼2 1¼1¼1¼1¼1¼2 22 21¼1¼1¼1¼1¼1¼1¼11¼11¼1¼ -UP1¼ -UP1¼ -UP1¼ -UP<55FT² BEDROOM 2 KITCHEN 9'-0" CLG UTILITY CONC. UTILITY CONC. BATH PATIO BEDROOM 2 PATIO MSTR 9'-0" CLG MSTR BEDROOM BATH LIVING ROOMLIVING ROOM BATH 9'-0" CLG 9'-0" CLG PATIO CONC. MSTR UTILITY BATH UTILITY BEDROOM LIVING ROOM MSTR 9'-0" CLG MSTR 9'-0" CLG MSTR 9'-0" CLG LIVING ROOM KITCHEN BATH MSTR <55FT² <55FT² LIVING ROOM LIVING ROOM BEDROOM CONC. CONC. 9'-0" CLG KITCHEN 9'-0" CLG BATH 9'-0" CLG BATH BEDROOM BATH BEDROOM BEDROOM LIVING ROOM BATH KITCHEN BEDROOM BATH 9'-0" CLG 9'-0" CLG 9'-0" CLG BEDROOM 3BEDROOM 3 9'-0" CLG PATIO BATHKITCHEN BEDROOM BATH BATH LIVING ROOM 9'-0" CLG BEDROOM 2 <55FT² UTILITY BATH BATH 9'-0" CLG KITCHEN PATIO BEDROOM 2 UTILITY KITCHEN PATIO WIC 9'-0" CLG BEDROOM 3 <55FT² BEDROOM 2 9'-0" CLG <55FT² 9'-0" CLG 8'-0" CLG 9'-0" CLG 9'-0" CLG CONC. 9'-0" CLG UTILITY CONC. MSTR BEDROOM 2 PATIO 9'-0" CLG BEDROOM 3 UTILITY 8'-0" CLG 9'-0" CLG9'-0" CLG WIC CONC. 9'-0" CLG <55FT² PATIO KITCHEN <55FT² BATH BEAMBEAM BEAM BEAMBEAM BEAM BEAM BEAMBEAM BEAM BEAM BEAM BEAMBEAM BEAM BEAM BEAM BEAMBEAM BEAM BEAMBEAM BEAM BEAM 1¼ -UP12"1 2 3 4 5 6 7 8 2" WATER SUPPLY LINE2" DERINGER 30 (DCDA)1 -2 -3 -4 -5 -6 - 8 - WATER FLOW ALARM SWITCH WIRED TO ALARM BELL 1" VALVE FOR DRAIN1" DRAIN LINE PIPED TO EXTERIOR OF BUILDING WATER PRESSURE GAUGE 6" ALARM BELL INSTALLED ON EXTERIOR OF BUILDING RISER LEGEND 2"7 -UPRIGHT SPRINKLER TO PROTECT RISER ALL CONTROL VALVE HANDLES TO BE REMOVED1 - RISER NOTES AND PLACED IN HEAD BOX AT TIME OF FINALWIRING OF FLOW SWITCH AND BELL TO BE BY OTHERS2 -2" SUPPLY LINE TO BE PROVIDED BY OTHERS3 - 1" MALE ADAPTER 11 10 9 -2" CHECK VALVE10 -1/2" AUTOMATIC BALL DRIP11 - 9 2½" SINGLE OUTLET OPEN SNOOT FDC WITH BREAKAWAY CAP 2"2"2½" X 0-8 GALVANIZED NIPPLE 2½" SINGLE INLET FDCWITH BREAK AWAY CAP 2" CHECK VALVE 6" 120VAC ALARM BELL TO BE CONNECTED TO (INSTALLATION AND 1"WIRING BY OTHERS) WATER FLOW SWITCH. 2" 2" FEMALE ADAPTER GRADEGRADE2"2"2"2"2" MALE ADAPTER½" X 0-6 GALV NIPPLE½" GALVANIZED WALL PLATE ½" GALVANIZED COUPLING ½" GALVANIZED 45° 1 X ½" RC ½" AUTOMATIC BALL DRIP 3'-0"FSI START GRAVEL91' PVC211' PVC6"6"61' PVC2"TAHOMA BOULEVARD SE105' DI 52 30' DI 52 33' PVC 1 0 5 ' D I 5 2 27' DI 526' DI 5256' PVC10' PVC 178' PVC52' PVC224' PVC 127' PVC32' PVC2"7' PVC 2" 10' PVC 6"6" 8 "6"6" 6"6"6" 2"2"2"30' PVC9' PVC 2"2"2" 6" SCOPE OF WORK: INSTALL NEW NFPA 13R FIRE SPRINKLER SYSTEM THROUGHOUT NEW RESIDENCE PER NFPA 13R (2019) GENERAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE OWNER TO MAINTAIN THE INTEGRITY OF THE SPRINKLER SYSTEM. 2. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 3. ALL SYSTEM PIPING SHALL BE TESTED AT STATIC PRESSURE PER NFPA 13D. 4. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13D (2019). 5. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 6. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 7. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. DESIGN NOTES: 1. RISER ASSEMBLY LOCATED IN ATTACHED RISER ROOM (FSI START POINT). 2. SYSTEM TO BE DESIGNED IN ACCORDANCE WITH NFPA #13R MULTI FAMILY RESIDENCE. 3. PLAN SUBMITTAL TO AND APPROVAL BY CITY OF YELM. 4. MATERIALS PER NFPA #13R STANDARDS AS SELECTED BY FSI. 5. TESTING PER NFPA #13R AND CITY OF YELM. 6. TYPICAL HANGERS TO BE TOLCO FIG. 24, 28M & 29 UNLESS NOTED OTHERWISE FIELD NOTES: 1. ALL NEW PIPE IS TO BE CPVC. 2. ALL NEW FITTINGS ARE TO BE CPVC. 3. DESIGN CRITERIA TO BE BASED ON NFPA 13R: A. SPRINKLER SPACING NOT TO EXCEED (16' X 16') OR (8') OFF OF WALLS MAXIMUM. B. MINIMUM PRESSURE AND FLOW FOR SPRINKLERS SPACED 16' X 16' = 13 GPM @ 7 PSI. TOLCO FIG. #28M NTS HANGER TYPE CP ATTIC INSULATION (BY OTHERS). BOTTOM CHORD OF TRUSS USE BATT TYPE INSULATION GWB CEILING (BY OTHERS). USE BATT TYPE TENT FIRE SPRINKER PIPEBEFORE INSULATING ATTIC WET PIPE FREEZE CPVC FIRE SPRINKLER PIPE FOR TENTING INSULATION FOR TENTING. NTS PROTECTION DETAIL TOLCO FIG. #24 NTS HANGER TYPE CP NTS HANGER TYPE CP TOLCO FIG. #29 1 FP1 C. PEND155RA1664½"½"CHQR½"1"4.9BRBRCHQRQR1"QRCH155QRDRY HSW5.6198200CHRELIABLEWHDRY ECSWBR1555.6124N/A24155WH4.9C. PEND12VK494VIKINGVIKINGVK494VIKNGVK178UPRIGHTVIKINGVK4674.9REVISIONS: REV# DATE: SCALE: DATE BY HANGER LEGEND: DESCRIPTION AHJ: CONTRACT WITH: SHEET NUMBER: REVIEWED BY: DRAWN BY: JOB NUMBER: DRAWING SYMBOLS: T D TOP BEAM CLAMP W/ STRAP H X - S SAMMY SUPER SCREW (GST20/30) TRAPEZE CP CPVC HANGER HILTI KWIK HUS-EZ SD SAMMY SIDEWINDER (SWDR 516)TOTAL THIS PROJECT =THRDTYPEMFR259ESCTEMPRESPSYMQTYFINISHKSINSPRINKLER LEGEND(SEE CHART) - ELEVATION - CENTERLINE A.1 - HYDRAULIC NODE - WELDED - FLEXIBLE GROOVED FFAFF CC DATUMDATUM 1 COUPLING - BRANCHLINE - ELEVATION10'-10"- SEISMIC BRACE LL TSTS DECK PIPE TAG DECK & LENGTH CUT #1 NUMBER - CENTERLINE 9'-0- PIPE HANGER - PIPE SIZE - RIGID GROOVED CAC LL0'-10"0'-10"OF PIPE TOOF PIPE TO COUPLING AS NOTED CCS 05/17/22 7677 CITY OF YELM JNZ FP1 OF 2 YELM, WA 9859715035 BERRY VALLEY ROAD SETAHOMA BLVD APARTMENTSPUYALLUP, WA 98371 SCHUUR BROS INC GC: JERRY SCHUUR - 253-651-3786 PO BOX 597 1524 45TH STREET EAST, SUITE 102 SUMNER, WA 98390 (253) 826-0099WWW.FIRESPRINKLERSINC.COM BUILDING SECTION A SCALE: NTS SCALE: 1/8" = 1'-0"NORTHVICINITY MAPMAIN FLOOR - SPRINKLER PIPING PLAN NORTHSCALE: NTS SCALE: NTSNORTH BUILDING 4 SITE PLAN SCALE: NTS RISER DETAIL HYDRAULICALLY DESIGNED GPM FLOWING: 54 1130 56 HYDRAULICALLY DESIGNED DATE & TIME: THIS SYSTEM IS NOT RESIDUAL: - THIS SYSTEM IS STATIC: - FLOW TEST - HYDRAULIC DESIGN INFO "OFFSET" HANGER & RESTRAINER HARDENED HEX HEAD SELF THREADING SCREWIS FURNISHED WITH THE HANGER AND IS THEMINIMUM FASTENER SIZE ACCEPTABLE FOR CPVC AND IPS PIPE HARDENED HEX HEAD SELF THREADING SCREWIS FURNISHED WITH THE HANGER AND IS THEMINIMUM FASTENER SIZE ACCEPTABLE CPVC DOUBLE FASTENER STRAP TYPE HANGER "DOUBLE OFFSET" HANGER & RESTRAINER HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE WA CL# FIRESI*988RJ X +/- 105' OF 2" PVC SUPPLY (BY OTHERS) FIRE HYDRANT OF FLOW TEST) FIRE HYDRANT (BY OTHERS) (EFFECTIVE POINT GATE VALVE (BY OTHERS) EXISTING 8" WATER MAIN 2½" SINGLE SNOOT WALL FDC FIRE SPRINKLER RISER ROOM WITH KNOX BOX (BY OTHERS) DCDA LOCATED INSIDE RISER ROOM 6" PVC SUPPLY BLDG 1 BLDG 2 BLDG 3 BLDG 4THIS PERMIT 414 4 413 417 412 415 416 412 411 SITE Christopher Cameron Smith 0087-0618-C Level 3 Fire Sprinklers Incorporated FIRESI*988RJ 05/23/2022 1¼ -UP/DND DDD 2-BED UNIT UNIT 2F 2-BED UNIT UNIT 2G 3-BED UNIT UNIT 2A 2-BED UNIT UNIT 2D 1-BED UNIT UNIT 2E 2-BED UNIT UNIT 2H 3-BED UNIT UNIT 2B 2-BED UNIT UNIT 2C 32280.4' D W D W D DWWW W W W DN DN UP UP DN UP UP DN 1¼ -UP/DN1 404 421 1 11 11¼1¼1¼1 11¼ 1 11¼ 1 1¼1111 1 1 1 111¼1¼1¼11 111¼11¼111¼11¼11¼ 1 1¼1¼ 1¼ 1¼11¼11 11¼ 1 1 111¼1 11¼1¼11¼ 1 1111 11 1¼1 1¼ 1 11¼1 1 1 1¼1¼1 1¼11¼ 11¼1¼ 1 1 11¼1¼1¼ 1¼1¼11 1 1¼1 11 1 1¼11111 11¼11¼ 1 1111¼111¼11 1¼ 1 1¼1¼1¼1 1 1¼1¼1¼1 11¼11¼1 1¼ 1¼ 1¼1¼1¼1¼1¼11¼11 1¼1¼1 11¼11 1¼ 1 1¼11¼1¼ 11 11¼ 1¼ 1 1¼1¼111 1¼1¼1¼11 1 1¼1¼1 1¼1¼1¼11¼ 1¼1¼ 1¼11¼ 1¼1¼1¼ -UP/DN1¼ -UP/DN1¼ -UP/DN9'-0" CLG KITCHEN CONC. UTILITY BEDROOM 9'-0" CLG 9'-0" CLG <55FT² BATH <55FT² LIVING ROOM <55FT²BATH MSTR 9'-0" CLG BATH BEDROOM BEDROOM 3 BEDROOM 3 UTILITY BEDROOM 2 9'-0" CLG PATIO UTILITY BEDROOM BATH 9'-0" CLG LIVING ROOM BATH 9'-0" CLG BATH 9'-0" CLG BEDROOM 2 9'-0" CLG BEDROOM 2 WIC 9'-0" CLG UTILITY BEDROOM 2 LIVING ROOM KITCHEN BATH MSTR <55FT² BEDROOM 2 9'-0" CLG9'-0" CLG BATH 9'-0" CLG 9'-0" CLG PATIO UTILITY 9'-0" CLG BEDROOM 3 MSTR MSTR 9'-0" CLG 9'-0" CLG 9'-0" CLG KITCHEN LIVING ROOM 9'-0" CLG BEDROOM BEDROOM <55FT² BEDROOM MSTR <55FT² BATH PATIOPATIO CONC. CONC. PATIO LIVING ROOM BEDROOM 2 BATH BATHKITCHEN 9'-0" CLG MSTR CONC. BEDROOM MSTR 8'-0" CLG 9'-0" CLG BATH PATIO 9'-0" CLG CONC.CONC. BATH 9'-0" CLG CONC. BATH LIVING ROOM 8'-0" CLG BEDROOM MSTR 9'-0" CLG BATH PATIO BEDROOM 3 9'-0" CLG BATH KITCHEN CONC. UTILITY KITCHEN <55FT² <55FT² UTILITY KITCHEN PATIO LIVING ROOM 9'-0" CLG WIC KITCHEN LIVING ROOM UTILITYBEAM BEAM BEAM BEAM BEAM BEAM BEAM BEAM BEAM BEAM BEAMBEAM BEAMBEAM BEAMBEAM BEAM BEAM BEAM BEAMBEAM BEAM BEAM BEAM1¼ -UP/DN1¼ -DNDD DD 2-BED UNIT UNIT 3E 2-BED UNIT UNIT 3H 3-BED UNIT UNIT 3B 2-BED UNIT UNIT 3C 2-BED UNIT UNIT 3F 2-BED UNIT UNIT 3G 3-BED UNIT UNIT 3A 2-BED UNIT UNIT 3D 32280.4' W W W WWD W W WD D D DN DN DNDN1¼ -DN1¼ -DN1¼ -DN1¼ -DN1¼ -DN1¼ -DN1¼ -DN4004 4003 4002 4001 403 401 423 419 402 420 1¼1 1¼1 1¼ 1 1 1¼1¼1¼1¼11 1¼1¼ 1 1¼1¼ 1 1¼1¼1¼11¼ 1 111¼1¼1111 11¼ 1¼ 11¼1¼1¼1¼1 1¼111 1¼1¼1¼1¼1¼1¼1¼1¼11¼1 1 11 1¼11¼1¼ 1¼ 1 1¼1¼1¼ 1 11¼1¼111 1¼1¼1 11 1¼1¼1¼1¼11¼1¼11¼1 1111¼1¼1 11¼1¼11¼ 1 1¼11 11 11¼1¼1¼1 11 11¼1¼ 1¼ 1 11 11 1 1¼1¼1¼11¼1¼1 1¼1¼1 1 1¼1 1 11¼1¼1¼1¼11¼ 1 1¼1¼11 1 1¼ 1¼ 1¼111¼1¼1¼1¼1¼ 1¼1¼1¼ 1¼ 9'-0" CLG MSTR 9'-0" CLG LIVING ROOM KITCHEN BATH MSTR <55FT² <55FT² LIVING ROOM LIVING ROOM BEDROOM CONC. CONC. 9'-0" CLG KITCHEN 9'-0" CLG BATH 9'-0" CLG BATH BEDROOM BATH BEDROOM BEDROOM LIVING ROOM BATH KITCHEN BEDROOM BATH 9'-0" CLG 9'-0" CLG 9'-0" CLG BEDROOM 3BEDROOM 3 9'-0" CLG PATIO BATHKITCHEN BEDROOM BATH BATH LIVING ROOM 9'-0" CLG BEDROOM 2 <55FT² UTILITY BATH BATH 9'-0" CLG KITCHEN PATIO BEDROOM 2 UTILITY KITCHEN PATIO WIC 9'-0" CLG BEDROOM 3 <55FT² BEDROOM 29'-0" CLG <55FT² 9'-0" CLG 8'-0" CLG 9'-0" CLG 9'-0" CLG CONC. 9'-0" CLG UTILITY CONC. MSTR BEDROOM 2 PATIO 9'-0" CLG BEDROOM 3 UTILITY 8'-0" CLG 9'-0" CLG9'-0" CLG WIC CONC. 9'-0" CLG <55FT² PATIO KITCHEN <55FT² BATH <55FT² BEDROOM 2 KITCHEN 9'-0" CLG UTILITY CONC. UTILITY CONC. BATH PATIO BEDROOM 2 PATIO MSTR 9'-0" CLG MSTR BEDROOM BATH LIVING ROOMLIVING ROOM BATH 9'-0" CLG 9'-0" CLG PATIO CONC. MSTR UTILITY BATH UTILITY BEDROOM LIVING ROOM MSTR 9'-0" CLG MSTR C. PEND155RA1664½"½"CHQR½"1"4.9BRBRCHQRQR1"QRCH155QRDRY HSW5.6200CHRELIABLEWHDRY ECSWBR1555.6N/A155WH4.9C. PEND-----VK494VIKINGVIKINGVK494VIKNGVK178UPRIGHTVIKINGVK4674.9REVISIONS: REV# DATE: SCALE: DATE BY HANGER LEGEND: DESCRIPTION AHJ: CONTRACT WITH: SHEET NUMBER: REVIEWED BY: DRAWN BY: JOB NUMBER: DRAWING SYMBOLS: T D TOP BEAM CLAMP W/ STRAP H X - S SAMMY SUPER SCREW (GST20/30) TRAPEZE CP CPVC HANGER HILTI KWIK HUS-EZ SD SAMMY SIDEWINDER (SWDR 516)THRDTYPEMFRESCTEMPRESPSYMQTYFINISHKSINSPRINKLER LEGEND(SEE CHART) - ELEVATION - CENTERLINE A.1 - HYDRAULIC NODE - WELDED - FLEXIBLE GROOVED FFAFF CC DATUMDATUM 1 COUPLING - BRANCHLINE - ELEVATION10'-10"- SEISMIC BRACE LL TSTS DECK PIPE TAG DECK & LENGTH CUT #1 NUMBER - CENTERLINE 9'-0- PIPE HANGER - PIPE SIZE - RIGID GROOVED CAC LL0'-10"0'-10"OF PIPE TOOF PIPE TO COUPLING AS NOTED CCS 05/17/22 7677 CITY OF YELM JNZ FP2 OF 2 YELM, WA 9859715035 BERRY VALLEY ROAD SETAHOMA BLVD APARTMENTSPUYALLUP, WA 98371 SCHUUR BROS INC GC: JERRY SCHUUR - 253-651-3786 PO BOX 597 1524 45TH STREET EAST, SUITE 102 SUMNER, WA 98390 (253) 826-0099WWW.FIRESPRINKLERSINC.COM NORTHSCALE: 1/8" = 1'-0" SECOND LEVEL - SPRINKLER PIPING PLAN SCALE: 1/8" = 1'-0" THIRD LEVEL - SPRINKLER PIPING PLAN NORTHHYDRAULICALLY DESIGNED GPM FLOWING: 54 1130 56 HYDRAULICALLY DESIGNED DATE & TIME: THIS SYSTEM IS NOT RESIDUAL: - THIS SYSTEM IS STATIC: - FLOW TEST - HYDRAULIC DESIGN INFO WA CL# FIRESI*988RJ X 16' X 16' RESIDUAL: HYDRAULIC DESIGN INFO 53.00 GPM @ 49.766 PSI THIS AREA HAS BEEN HYDRAULICALLY CALCULATEDTO DELIVER A RESIDENTIAL COVERAGE (NFPA 13D) OF: REMOTE AREA #4 MAX AREA/HEAD: SYSTEM DEMAND: DENSITY: K-FACTOR: HYDRAULICALLY DESIGNED THIS SYSTEM IS 54 HYDRAULICALLY DESIGNED AREA 4 56 .05 GPM / SQ FT -DATE & TIME: 4.9K 13 GPM @ 7.0 PSI USING 16' X 16' HEAD SPACING GPM FLOWING: - SYSTEM DESIGN - - FLOW TEST - REMOTE AREA: THIS SYSTEM IS NOT STATIC: 1130 Christopher Cameron Smith 0087-0618-C Level 3 Fire Sprinklers Incorporated FIRESI*988RJ 05/23/2022