Loading...
13R submittal NO DOMESTIC SHUT OFF (3)Date Revised:AUG 2007 TYCO MATERIAL SAFETY DATA SHEET Supersedes:APR 2007 Information on this form is furnished solely for the purpose of compliance with the U.S.Occupational Safety and Health Act ,the Canadian Hazardous Products Act and Controlled Products Regulations and shall not be used for any other purpose. IPS Corporation urges the customers receiving this Safety Data Sheet to study it carefully to become aware of the hazards,if any,of the product involved. In the interest of safety,you should notify your employees,agents and contractors of the information on this sheet. SECTION I - PRODUCT INFORMATION :seicnegremEnoitatropsnarTEMANS'REILPPUSEMANS'RERUTCAFUNAM 0039-424)008(:CERTMEHCstcudorPgnidliuBdnaeriFocyTocyTrofnoitaroproCSPI :seicnegremElacideMSSERDDASSERDDA ChtroN154,973xoB.O.P,.tSniaM.S90171 42(YNAPMOCE3eunevAnonna Hour No.) (800)451-8346 Gardena,CA.90248 U.S.A. (310)898-3300 Lansdale,PA 19446,USA Business:Tyco (215)362-0700 :EMANEDARTYLIMAFdnaEMANLACIMEHC epiPcitsalPCVPCroftnemeCCOVwoL005PFT®RETSAMEZALBstnevloScinagrOdnaniseRCVPCfoerutxiM SECTION II - HAZARDOUS INGREDIENTS, EXPOSURE LIMITS, TRANSPORT & WHMIS DATA None of the ingredients below are listed as APPROX %ACGIH ACGIH TNOPUDAHSOAHSO carcinogens by IARC, NTP, OSHA or ACGIH.LETS)B(LEA)A(05CL05DLLETSLEPLETSVLTTHGIEWYB#SAC .PA.N.PA.N.PA.N.PA.N02-018-28-84686)CVPC(niseRedirolhClynivyloPdetanirolhC Tetrahydrofuran (THF), Stabilized 109-99-9 30 - 60 50 PPM Skin 100 PPM Skin 200 PPM 250 PPM Oral: 2880 mg/kg (rat) Inhalation 3 hrs.50 PPM 75 PPM 21,000 PPM (rat) Methyl Ethyl Ketone (MEK)78-93-3 3 - 7 200 PPM 300 PPM 200 PPM 300 PPM Oral: 3.98 g/kg (rat) Inhalation 4 hrs. Dermal: 8-10 mg/kg (rabbit) 4,000 PPM (rat) ,OLCLnoitalahnI,)tar(gk/gm0091:larOMPP05nikSMPP025-11-49-801enonaxeholcyC Dermal: 1.0 g/kg (rabbit)4 hrs: 2000 PPM rat) OLCLnoitalahnI)tar(gk/g57.9:larOMPP0001MPP057MPP057MPP00531-71-46-76enotecA Dermal: 20 g/kg (rabbit)4 hrs: 16,000 PPM (rat) All of the constituents of IPS adhesive products are listed on the TSCA inventory of chemical substances maintained by the US EPA and/or the Canadian Domestic Substance List (DSL),or are exempt from such listings. (A) Dupont and BASF mfg's Acceptable Exposure Limit (AEL)guidelines for 8 hour and 12 hour TWA, (B) Dupont/BASF recommended STEL for 15 minute TWA. DOT,IATA,IMO/IMDG SHIPPING IN SNOITANGISEDDRAZAHLAICEPSNOITAMROF Proper Shipping Name:Adhesives EXCEPTION: Case quantities of cement in Hazard Class:3 containers of less than one liter may be HMIS NFPA HAZARD RATING Identification Number:UN 1133 shipped as LIMITED QUANTITY or HEALTH:2 2 0 -MINIMAL Packing Group:II CONSUMER COMMODITY, ORM-D FLAMMABILITY:3 3 1 -SLIGHT ETAREDOM-210:YTIVITCAERdiuqiLelbammalF:deriuqeRlebaL TDG INFORMATION SUOIRES-3EVITCETORP TDG CLASS:FLAMMABLE LIQUID EREVES-4H-B:TNEMPIUQE3 SHIPPING NAME:ADHESIVES (TETRAHYDROFURAN) )seitivitcagnidlew-tnevloslamronrof(nikS/dnaH,eyE=BIIGP,3311:REBMUNNU WHMIS CLASSIFICATION:CONTROLLED PRODUCT H =Eye,Hand/Skin,Respiratory Protection and Impermeable Apron (splash/ CLASS B,DIVISION 2 immersion risks) CLASS D,DIVISION 2B SECTION III - PHYSICAL DATA TNIOPGNIZEERF)C°/F°(TNIOPGNILIOBRODOECNARAEPPA serhT(laerehtEdiuqilypurysmuidem,deR )C°59-(F°931-)C°75(F°331)MPP05-2=dloh Based on Acetone SPECIFIC GRAVITY @ 73°F ±3.6°(23°C ±2°) VAPOR PR )%(EMULOVYBELITALOVTNECREP).gHmm(ERUSSE %08-07:xorppAgniliobtsrifnodesab.gHmm091040.0±0.1lacipyT component,Acetone @ 68°F (20°C) RETAWNIYTILIBULOS)1=CAUB(ETARNOITAROPAVE)1=riA(YTISNEDROPAV .retawnielbulosyletelpmocnoitroptnevloS0.1>94.2 Resin portion separates out. NOITAMROFNIHPNOITUBIRTSIDLIO/RETAWFOTNEICIFFEOC .PA.N.VA.N VOC STATEMENT Maximum VOC emissions as applied and tested per SCAQMD Rule 1168,Test Method 316A:490 grams/liter. After drying and curing there are negligible or no emissions. BlazeMaster® TFP-500 One Step Solvent Cement MSDS (Material Safety Data Sheet) Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Page  of 4 JUNE, 2008 TFP990 514 OFFSET C.P.V.C. - STEEL- COPPER HANGER SIZE MATERIAL FINISH PATENT No. 6,648,278. FUNCTION INSTALLATION WOOD #905 STEEL FEATURES #905 ORDERING 906 - 3/4" thru 2"pipe. - Carbon Steel. - Mil. Galvanized.. - - To support horizontal piping - C.P.V.C.,Copper or Steel. Hanger and restrainer in listed mounting positions - Top,Bottom or Side. Provides stability on vertical piping. - Per N.F.P.A13,13R and 13D on top,bottom or side of building element. Space by pipe type. Snap over pipe then squeeze strap back allowing pipe to slide freely. in : CPVC pipe - screw- no pre-drill. Copper pipe - Steel pipe - 1/4 x11/2 lag screw - no pre-drill. in : * 1 1/2 Offset. * 3/4 and 1” pipe size a e common center-line. * Leg design produces superior strength. * Offset edge eliminates abrasion. * Required screw has 5/16" hex head - included - Part # and pipe size. # sold separately. AFCON AFCON LISTINGS - EX 4231, EX 2551 906 FASTENERS #905 On 3/8" wood web use # backing nuts. - see drawing. - UL Listed per NFPA13 screw- no pre-drill. "" CPVC pipe - 1/4" or #14 Tek Screw. Copper pipe - 1/4" or #14 Tek Screw. Steel pipe - 1/4" or #14 Tek Screw. " " m d with 4/04 1 1/2” CAD FIRE SPRINKLER PIPE & FITTINGS SUBMITTAL SHEET No. 19–1.5 TD915 4–1.1.20 9/2001 TYCO FIRE PRODUCTS 451 North Cannon Avenue Lansdale, Pennsylvania 19446 www.tyco-fire.com TECHNICAL SERVICES TEL: (800) 381-9312 • FAX: (800) 791-5500 E-MAIL: techserv@tycofp.com Part No. Size Sch. T/O Wt. 80000 3/4"405/8"0.11 lb. 80001 1" 40 3/4"0.19 lb. 80002 1 1/4"40 7/8"0.26 lb. 80003 1 1/2"801"0.51 lb. 80004 2" 80 1 3/8"0.90 lb. 80005 2 1/2"8019/16"1.59 lb. 80006 3" 80 1 11 /16"2.41 lb. Tee Part No. Size Sch. T/O Wt. 80025 3/4"409/16"0.09 lb. 80026 1" 40 3/4"0.14 lb. 80027 1 1/4"40 7/8"0.21 lb. 80028 1 1/2"8011/16"0.40 lb. 80029 2" 80 1 1/4"0.79 lb. 80030 2 1/2"8011/2"1.14 lb. 80031 3" 80 1 13/16"1.82 lb. 90° ElbowReducing 90° Elbow CrossReducing Cross Part Size Sch. T/O Wt. No. 1 2 lb. 80015 1" x 3/4"40 11/16"11/16"0.28 Part No. Size Sch. T/O Wt. 80009 3/4"409/16"0.13 lb. 80010 1" 40 15/16"0.23 lb. 80011 1 1/4"4015/16"0.34 lb. 80012 1 1/2"8011/16"0.67 lb. 80013 2" 80 1 3/8"1.00 lb. 80014 2 1/2"8019/16"1.91 lb. 80008 3" 80 1 13/16"2.89 lb. Part No. Size Sch. T/O Wt. 80050 3/4"403/8"0.08 lb. 80051 1" 40 3/8"0.11 lb. 80052 1 1/4"40 3/4"0.20 lb. 80053 1 1/2"80 7/16"0.31 lb. 80054 2" 80 3/4"0.56 lb. 80055 2 1/2"80 3/4"0.89 lb. 80056 3" 80 1" 1.19 lb. 45° Elbow Fittings Nom.Pipe Size Avg. O.D. Inches Avg. I.D. Inches Wt. Lbs./Ft.Wt. H2O filled Pipe Lbs./Ft.Ft. of Pipe per Lift Wt. per Lift Lbs. 3/4"1.050 0.874 0.17 0.43 7875 1413 1" 1.315 1.101 0.26 0.67 5040 1320 11/4"1.660 1.394 0.42 1.07 2835 1191 11/2"1.900 1.598 0.55 1.40 2205 1136 2" 2.375 2.003 0.86 2.20 1260 1063 2 1/2"2.875 2.423 1.26 3.22 1215 1531 3" 3.500 2.952 1.87 4.79 720 1344 Introduction 2 2 11 T/O T/O T/O T/O Part Size Sch. T/O Wt. No. 1 2 lb. 80032 1" x 3/4"40 11/16"13/16"0.16 Pipe Technical Data Tyco Fire Products (TFP) BlazeMaster®CPVC pipe and fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFP BlazeMaster ®CPVC products are easier to install than traditional steel pipe systems, and at the same time, they provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. Sizes:3/4"– 3" Maximum Working Pressure:175 psi Approvals:UL, FM, CUL, NSF, Dade County, LPCB, MEA, and the City of Los Angeles Note:See current TFP BlazeMaster Installation Instructions and Technical Manual, for exact listing/approval information Manufacture Source:U.S.A. Material: Pipe:ASTM F442, SDR 13.5 Fittings:ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80) Color:Orange PRINTED IN USA PAGE 1 OF 4MFG. #5401205 - REV G 9/09 VSR-SG VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD AND GLUE-IN UNION FOR CPVC PIPE General Information The Model VSR-SG is a vane type waterfl ow switch for use on wet sprinkler systems using CPVC plastic fi ttings (manufactured by Tyco, Nibco, Victaulic, Ipex, and Spears Manufacturing Company) that use 1”, 1 ¼”, 1 ½”, or 2” pipe sizes. It is equipped with a union to accommodate installation in confi ned spaces. The VSR-SG contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a fl ow of 10 GPM (38 LPM) or more occurs downstream of the device. The fl ow condition must exist for a period of time necessary to overcome the selected retard period. UL, CUL and CSFM Listed Service Pressure: Up to 175 PSI (12,07 BAR) Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two openings provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifi cations: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fi tting. • Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 • Installation must be performed by qualifi ed personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. Specifi cations subject to change without notice. Stock Number: 1144460 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Enclosure The VSR-SG switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A fi eld installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Waterfl ow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfl ow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Potter Electric Signal Company, LLC • St. Louis, MO • Cust Service: 866-572-3005 • Tech Support: 866-956-0988 /Canada 888-882-1833 • www.pottersignal.com Thread Size Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)F C F C 1 2 NPT (R1 2) 155 175 68 79 175 (12) 100 150 38 66 4.9 2.25 (57) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identification Number (SIN) 12 x 12 (3.6x3.6) 13 (49) 7.0 (0.48) R351616 x 16 (4.9x4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5x5.5) 17 (64 3) 12.0 (0.83) 20 x 20 (6.1x6.1) 20 (75.7) 16.7 (1.14) Deflector - to - ceiling Maximum 1 (25mm) to 4 (100mm) 3. Type Adjustment Inch (mm) “A” Inch (mm) Face of fitting to ceiling Inch (mm) F1 3 4 (19.0)Min.=3 4 (19.1) Max.=11 2 (38.1) 3 16 -15 16 (4.7 - 24.0) F2 1 2 (12.7)Min.=15 16 (23.8) Max.=11 2 (38.1) 3 16 -1116 (4.7 - 17.4) Escutcheon*, F1 or F2, Data: *Note:Escutcheons F1 or F2 may be used with Model F1 Res 49 & 58 Recessed Pendent Sprinkler Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identification Number (SIN) 12 x 12 (3.6x3.6) 15 (57) 9.4 (0.65) R3516 14 x 14 (4.3x4.3) 16 (60.5) 10.6 (0.73) 16 x 16 (4.9x4.9) 17 (64.3) 12.0 (0.83) 18 x 18 (5.5x5.5) 19 (72) 15.0 (1.0) 20 x 20 (6.1x6.1) 22 (83.2) 20.2 (1.4) *Deflector - to - ceiling Maximum 4 (100mm) to 8 (203mm) *Note:The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth = 7 (178mm) 2.Beamspacingatorgreaterthan7.5ft.(2.3m)oncenter. Technical Data: F1 Res 49 Pendent and Recessed Pendent Thread Size Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)F C F C ½NPT (R½) 155 175 68 79 175 (12) 100 150 38 66 5.8 2.25 (57) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Ceiling -to- Deflector Inch (mm) Sprinkler Identification Number (SIN) 12 x 12 (3.6x3.6) 16 (61) 7.6 (0.53) 1-4 (25-100)R3513 14 x 14 (4.3x4.3) 16 (61) 7.6 (0.53) 16 x 16 (4.9x4.9) 16 (61) 7.6 (0.53) 18 x 18 (5.5x5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1x6.1) 22 (83.3) 14.4 (1.0) Technical Data: F1 Res 58 Pendent and Recessed Pendent •Model F1 Res 49 Recessed Pendent / FP •Model F1 Res 49 CCP Pendent 4. Fig. 4 Fig. 3 Thread Size Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) F C F°C F C ½NPT (R½)155 68 135 57 175 (12) 100 150 38 66 4.9 2.25 (57) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identification Number (SIN) 12 x 12 (3.6x3.6) 13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9x4.9) 14 (53) 8.2 (0.56) 18 x 18 (5.5x5.5) 18 (68.1) 13.5 (0.93) 20 x 20 (6.1x6.1) 20 (75.7) 16.7 (1.14) “A” Cover Adjustment Inch (mm) “B” CCP Height Inch (mm) 1 2 (12.7)15 16 (24) 3 16 (4.7)3 4 (19) CCP Options Data: FP Position “A” Inch (mm) Max. Recessed 7 16 (11) Min. Recessed 15 16 (24) FP Data “A”: FP push-on/thread-off escutcheon Technical Data: F1 Res 49 CCP and FP Note:Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR Quick Response Dry Sprinklers Bulletin 157 Rev. HBulletin 157 Rev. H Features The Model F3QR sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. Styles available Pendent Recessed FP Pendent Recessed F1 Pendent Concealed Horizontal Sidewall Recessed FP Horizontal Sidewall Recessed F1 Horizontal Sidewall 1½” (38mm) escutcheon adjustment on pendent sprinkler. ½” (13mm) escutcheon adjustment on recessed sprin- kler with push-on/ thread-off FP Model Escutcheon ring. 3/8” (9.5mm) cover plate adjustment on concealed sprinkler with push-on/ thread-off CCP Cover Plate. 3/4” (19mm) escutcheon adjustment on recessed sprinkler with F1 Escutcheon. Attractive appearance. Employs 3mm frangible glass bulb and galvanized nipple. Lengths available to accommodate installation di- mensions from 2” - to - 48” (51mm - to - 1219mm), in ¼” (6mm) increments. Available in a variety of plated and painted finishes. Polyester Coated Corrosion Resistant Sprinklers. US Patent Numbers 5,775,431 and 5,967,240. Approvals Listed by Underwriters Laboratories Inc. and UL Cer- tified for Canada (cULus) Style Response Sprinkler System Type Hazard Pendent Recessed Pendent Recessed F1 Pendent CCP Concealed (R5714) Quick Wet Pipe Dry Pipe All Preaction Light Ordinary Horizontal Sidewall Recessed Horizontal Sidewall (R5734) Quick Wet Pipe Dry Pipe All Preaction Light Certified by FM Approvals Style Response Sprinkler System Type Hazard Pendent Recessed F1 Pendent (R5714) Quick Wet Pipe Dry Pipe All Preaction Light Ordinary, Groups 1&2 Horizontal Sidewall Recessed F1 Horizontal Sidewall (R5734) Quick Wet Pipe Dry Pipe All Preaction Light NYC MEA 258-93-E 1. 2. • • • • • • • 3. 4. 5. 6. 7. 8. 9. 10. 1. 2. 3. Concealed (See Fig. 4) Recessed FP Pendent (See Fig. 3) Recessed F1 Horizontal Sidewall (See Fig. 9) Horizontal Sidewall (See Fig. 6) Pendent (See Fig. 1) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent / HB (See Fig. 2) Horizontal Sidewall / HB (See Fig. 7) Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPT or IS07-1 R1/2 Nominal K -Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F(68°C) 175°F(79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model F1 Res44 Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 211 (51 mm) 1/2" (13mm) +/- 1/4" (6mm) +/- 1/4" (6mm) 2-1/2" 2-1/4" 1-15/16" Top of Deflector Down from (57mm) (49mm) -- - --- Ceiling to Either 4" to 6" DIA. DIA. (100 to 1500 mm) or 6" to 12" (150 to 300 mm) Based on 5/16" Hydraulic Calculations 1/2" (13mm) (8mm) Dimensions F2 & FV Recessed Escutcheon Installation Model F1 Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe SystemsM Maximum Coverage Areae ft. x ft. (m x m) Flow Pressure gpm (1/min) psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 12 (45) 7.5 (0.52) 4 to 6 inches (100 to 150 mm) 14 x 14 (4.3 x 4.3) 14 (53) 10.2 (0.70) 15 x 15 (4.6 x 4.6) 15 (57) 11.6 (0.80) 16 x 16 (4.9 x 4.9) 16 (61) 13.3 (0.92) 16 x 18 (4.9 x 5.5) 18(68) 16.8(1.16) 16 x 20 (4.9 x 6.1) 23 (87) 27.4(l.89) 18 x 18 (5.5 x 5.5) 19 (72) 18.7(l.29) 12 x 12 (3.7 x 3.7) 14 (53) 10.2 (0.7) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3) 16(61) 13.2(0.91) 15 x 15 (4.6 x 4.6) 16 (61) 13.2 (0.91) 16 x 16 (4.9 x 4.9) 17 (64) 15.0 (1.03) 16 x 18 (4.9 x 5.5) 20 (76) 20.7(l.43) 16 x 20 (4.9 x 6. 1) 23(87) 27.4(1.89) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Reliable Page 10 of 15 May 2019 www.reliablesprinkler.com