Signed FA - Farrelli's PizzaBILL OF MATERIALS,MATRIX,FA-01 of 3& GENERAL INFOFIRE ALARM BILL OF MATERIALSFIRE ALARM - FARRELLI'S PIZZA - YELM813 W. YELM AVENUE, YELM, WASHINGTON 98597 SCOPE OF WORKBUILDING DESCRIPTION: RESTAURANTBUILDING OCCUPANCY: A-2SPRINKLERED: YESWIRING CLASS: BSCOPE:PERFORMANCE SYSTEMS INTEGRATION LLC IS PROVIDING A FIRE ALARM SYSTEM CONSISTING OF:·IO-64GD FIRE ALARM PANEL·INITIATING DEVICES·NOTIFICATION DEVICESSHEET INDEXVICINITY MAPAPPLICABLE BUILDING CODESCENTRAL STATION MONITORINGTRANSMISSION TYPE: (PHONE LINE, CELL, RADIO)COMMUNICATION TYPE: (4+2, CID)MONITORING COMPANY:ACCOUNT NUMBER:PHONE NUMBER:FIRE ALARM SUBMITTAL REQUIREMENTS1.The work site address and work activity location2.Work site owner or tenant contact name, address, and telephone number3.Contractor or installer information, including state electrical license number4.Description of work5.Three sets of scaled plans, not smaller than 11 x 17 inches. Your plans must include:5.1.Floor plan indicating the use of all rooms5.2.Riser Diagram5.3.Location of all alarm-initiating devices5.4.Location of all alarm notification devices, including candela ratings for visible devices5.5.Location of alarm control, transponders, and notification power supplies5.6.Annunciation5.7.Power connection5.8.Battery calculations5.9.Voltage drop calculations5.10.Wiring types and sizes5.11.Manufacturer's data sheets with model numbers and information for equipment, devices, andmaterials5.12.Ceiling height and construction details5.13.Interface of fire safety control functionsWIRE SCHEDULESHEET #DESCRIPTIONREV 1REV 2REV 3FA-01BILL OF MATERIALS, MATRIX, & GENERAL INFOFA-02DEVICE LAYOUT, RISER, CALCULATIONS & FACPDETAILFA-03DEVICE & STANDARD DETAILSTOTAL NEWSYMBOLMFG.MODEL #DESCRIPTIONDETAILREV1REV2REV 31ESTIO-64GDFIRE ALARM CONTROL PANEL1ESTSA-ETHINTERNET PROGRAMMING INTERFACE2DURACELLDURA12-8F212V 8AH SEALED LEAD ACID BATTERY1ESTSIGA-278MANUAL PULL STATION1ESTSIGA-OSDINTELLIGENT OPTICAL SMOKE DETECTOR1ESTSIGA-SB4DETECTOR BASE1ESTSIGA-CT2DUAL INPUT MODULE1ESTSIGA-CT1SINGLE INPUT MODULE4ESTWG4RF-HVMCHORN/STROBE - WEATHERPROOF4EST449WEATHERPROOF NOTIFICATIONAPPLIANCE BOX1ESTGCAVRFHORN/STROBE - CEILING MOUNT1ESTGRSW-10LED MOUNTING PLATE5ESTG4AVRFHORN STROBE - WALL MOUNT3ESTG4VRFSTROBE - WALL MOUNTNOTES TO INSTALLING CONTRACTOR1.ALL DEVICES PROVIDED AS PART OF THIS PROJECT SHALL BE INSTALLED PRIOR TO CONTACTINGPERFORMANCE SYSTEMS INTEGRATION, LLC (PSI) FOR SCHEDULING A PROGRAMMING TECHNICIAN.2.WIRING MUST BE COMPLETE, DRY, AND FREE OF SHORTS AND GROUNDS WITH NO EXCEPTIONS PRIOR TOCONTACTING PSI FOR SCHEDULING A PROGRAMMING TECHNICIAN..3.WHEN CONDUIT IS REQUIRED, CONDUIT SIZE SHALL CONFORM TO CONDUIT FILL CAPACITIES AS PER THEREQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NFPA 70) AND THE LOCAL JURISDICTION.4.UNDERGROUND AND EXTERIOR CONDUITS SHALL HAVE WATER-TIGHT FITTINGS AND WIRE SHALL BEAPPROVED FOR WET LOCATIONS AS PER THE REQUIREMENTS OF NFPA 70 AND THE LOCAL JURISDICTION.5.ALL FIRE ALARM DEVICES AND JUNCTION BOXES EXPOSED TO THE WEATHER OR INSTALLED IN BELOWGRADE AREAS SHALL BE LISTED FOR USE IN A WET ENVIRONMENT. ALL DEVICES SHALL BE INSTALLED PERTHE MANUFACTURER'S RECOGNIZED WEATHER-/WATER-TIGHT INSTRUCTIONS. NO EXCEPTIONS.6.PROGRAMMING OF THE FIRE ALARM SYSTEM AND ASSOCIATED POINT DESCRIPTIONS WILL BE BASED ONTHESE DESIGN DRAWINGS. PSI MUST BE NOTIFIED OF ANY CHANGES TO ROOM USE OR DESIGNATIONS INWRITING. ANY CORRECTIONS RESULTING FROM CHANGES NOT SUBMITTED TO PSI MAY RESULT INADDITIONAL SYSTEM DEVICE COSTS AND/OR PROGRAMMING CHARGES.7.ALL DEVICES CONTAINING END-OF-LINE RESISTORS SHALL BE CLEARLY LABELED.8.WHEN APPLICABLE, SERIAL NUMBERS (BARCODE LABELS) FROM INSTALLED DEVICES SHALL BE ATTACHEDTO EITHER THE REDLINED DRAWING SET OR THE SUPPLIED BARCODE WORKSHEET.9.ANY DEVIATION FROM DESIGN MUST BE INDICATED ON PERFORMANCE SYSTEMS INTEGRATION, LLC (PSI)SHOP DRAWINGS AND RETURNED TO PSI UPON COMPLETION OF THE JOB.LABELING CONVENTIONEXAMPLE: 1.1-1S1-1S 1 - 1DEVICE NUMBER IN SEQUENCESPEAKER CIRCUIT #1 . 1 - 1DEVICE NUMBER IN SEQUENCENAC CIRCUIT #BOOSTER POWER SUPPLY #EXAMPLE: A,2B3,C2,X2 B 3WIRE DESIGNATION WHEN >1 OF SAME TYPECABLE TYPE (SEE WIRE SCHEDULE)NUMBER OF CABLES WHEN > 1A , 2 B 3 , C 2 , XONE CABLE, X-TYPEONE CABLE, C-TYPE, DESIGNATION "2"TWO CABLES, B-TYPE, DESIGNATION "3"ONE CABLE, A-TYPEA123456789MANUAL FIRE ALARM PULL STATIONSYSTEM INPUTS123456789BCDEFGHIJKLMNOPQ•SMOKE DETECTORSPRINKLER WATER FLOW SWITCHSPRINKLER CONTROL VALVE TAMPER SWITCHFIRE ALARM AC POWER FAILUREFIRE ALARM SYSTEM LOW BATTERYFIRE ALARM SYSTEM OPEN CIRCUITFIRE ALARM SYSTEM SHORT CIRCUITFIRE ALARM SYSTEM GROUND FAULTACT
I
V
A
T
E
C
O
M
M
O
N
A
L
A
R
M
S
I
G
N
A
L
I
N
D
I
C
A
T
O
R
ACT
I
V
A
T
E
C
O
M
M
O
N
S
U
P
E
R
V
I
S
O
R
Y
S
I
G
N
A
L
I
N
D
I
C
A
T
O
R
ACT
I
V
A
T
E
C
O
M
M
O
N
T
R
O
U
B
L
E
S
I
G
N
A
L
I
N
D
I
C
A
T
O
R
ACT
I
V
A
T
E
A
U
D
I
B
L
E
N
O
T
I
F
I
C
A
T
I
O
N
D
E
V
I
C
E
S
I
G
N
A
L
U
N
T
I
L
S
I
L
E
N
C
E
D
ACT
I
V
A
T
E
V
I
S
I
B
L
E
N
O
T
I
F
I
C
A
T
I
O
N
D
E
V
I
C
E
U
N
T
I
L
S
I
L
E
N
C
E
D
TRA
N
S
M
I
T
S
U
P
E
R
V
I
S
O
R
Y
S
I
G
N
A
L
T
O
S
U
P
E
R
V
I
S
I
N
G
S
T
A
T
I
O
N
TRA
N
S
M
I
T
T
R
O
U
B
L
E
S
I
G
N
A
L
T
O
S
U
P
E
R
V
I
S
I
N
G
S
T
A
T
I
O
N
DIS
P
L
A
Y
F
A
C
P
S
T
A
T
U
S
A
T
L
C
D
A
N
N
U
N
C
I
A
T
O
R
ACT
I
V
A
T
E
E
X
T
E
R
I
O
R
S
P
R
I
N
K
L
E
R
N
O
T
I
F
I
C
A
T
I
O
N
D
E
V
I
C
E
TRA
N
S
M
I
T
F
I
R
E
A
L
A
R
M
S
I
G
N
A
L
T
O
S
U
P
E
R
V
I
S
I
N
G
S
T
A
T
I
O
N
ACT
I
V
A
T
E
C
O
M
M
O
N
M
O
N
I
T
O
R
S
I
G
N
A
L
I
N
D
I
C
A
T
O
R
SYSTEM OUTPUTSFIRE ALARMCONTROL UNITNOTIFICATIONNO ENTRY = N/AFIRE SAFETYCONTROLABCDEFGHIJKLMNOPQ•••••••••••••••••••••••••••••••••FUNCTIONAL MATRIX1FA-03REVISIONSPLOT DATEPROJECT NUMBERSHEET TITLECHECKED BYDRAWN BYKMMBFARRELLI'S PIZZA - YELM
ARCH D - SIZE 36X24IN
813 W. YELM AVENUESHEET Fire Alarm | Security | CCTV | Communications
19310 North Creek Parkway, Suite 109 - Bothell, WA 98011 - info@psintegrated.com - Phone (425) 368-4201 - Fax (425) 368-4208 - License WA-PERFOSI812NO
Fire Alarm | Security | CCTV | Communications
19310 North Creek Parkway, Suite 109 - Bothell, WA 98011 - info@psintegrated.com - Phone (425) 368-4201 - Fax (425) 368-4208 - License WA-PERFOSI812NO
YELM, WASHINGTON 98597PERMIT NUMBERXXXXXXX-XXREV.TITLEDATE11022806/15/2022NICET FIRE ALARM SYSTEMSGARRICK K. YOUNGBERG, SETLEVEL IV: 90549EXP: 12/01/2023DWPC2FA-033FA-034FA-035FA-036FA-037FA-037FA-032018 INTERNATIONAL BUILDING CODE2018 INTERNATIONAL FIRE CODE2016 NFPA 722020 NFPA 701010ANSUL SYSTEM•••••8FA-03
WP70CDMATERIALPRODUCTTRADENAMEMODELNUMERMATERIALPRODUCTTRADENAMEMODELNUMER18"x36"18"x48"14"x48"KCL-CUST 24"x24"24"x3624"x3624"x30"24"x72"24"x72"KCL-CUST 14"x48"E1D1H1VFYVFYVFYVFYNVFY15CDWP70CD75CD75CDC30CD75CDWP70CD15CDWP70CD15CD75CDD1.1-01L1M01L1S01L1M031.1-051.1-041.1-061.1-071.1-081.2-021.2-011.2-041.2-031.2-05B1.1B1.1B1.1B2.1B2.1B2.1B1.11.1-02AAB1.1B2.175CD1.1-03B1.1L1M02ANSULSYSTEMAL1M04SYMBOL LEGENDFIRE ALARM CONTROL PANELSYMBOLDESCRIPTIONINTELLIGENT OPTICAL SMOKE DETECTORSTROBE - WALL MOUNTEDDDUAL INPUT MODULEHORN/STROBE - WEATHERPROOFWPCHORN/STROBE - CEILING MOUNTHORN/STROBE - WALL MOUNTMANUAL PULL STATIONTAMPER SWITCH - F.B.O WATER FLOW SWITCH - F.B.OEND OF LINE RESISTORSINGLE INPUT MONITOR MODULEFURNISH BY OTHERF.B.OFIRST LEVELADAAL1M01L1S01L1M02TO TWOPHONE LINES75CD1.1-0115CD1.1-0275CD1.1-0315CD1.1-0415CD1.1-05WP70CD1.1-06WP70CD1.1-07B1.1B1.1B1.175CD1.2-01B1.130CDC1.2-0275CD1.2-03WP70CD1.2-04WP70CD1.2-05B1.1B1.1B1.1B1.1B1.1L1M0375CD1.1-08B1.1B1.1B1.1ANSULSYSTEML1M04ADEVICE LAYOUT, RISER,CALCULATIONS & FACP DETAILFA-02 of 3REVISIONSPLOT DATEPROJECT NUMBERSHEET TITLECHECKED BYDRAWN BYKMMBFARRELLI'S PIZZA - YELM
ARCH D - SIZE 36X24IN
813 W. YELM AVENUESHEET Fire Alarm | Security | CCTV | Communications
19310 North Creek Parkway, Suite 109 - Bothell, WA 98011 - info@psintegrated.com - Phone (425) 368-4201 - Fax (425) 368-4208 - License WA-PERFOSI812NO
Fire Alarm | Security | CCTV | Communications
19310 North Creek Parkway, Suite 109 - Bothell, WA 98011 - info@psintegrated.com - Phone (425) 368-4201 - Fax (425) 368-4208 - License WA-PERFOSI812NO
YELM, WASHINGTON 98597PERMIT NUMBERXXXXXXX-XXREV.TITLEDATE11022806/15/2022NICET FIRE ALARM SYSTEMSGARRICK K. YOUNGBERG, SETLEVEL IV: 90549EXP: 12/01/2023SCALE: 1/8" = 1'-0"1FIRST LEVEL - FIRE ALARM DEVICE LAYOUTN1'4'8'16'SCALE RULERSCALE: NTS2RISER DIAGRAM00:00:0001/01/07,BATTERY12V 8AHBATTERY12V 8AHNUETRALEARTH GNDLINE(+)(-)(+)(-)(+)(-)TB8TB1TB2TB6NAC 1-NAC 2+NAC 1+NAC 2-NAC 3-NAC 4+NAC 3+NAC 4-TONOTIFICATIONDEVICESTO SLCDEVICESRELAYTERMINALSIO-64 FIRE ALARM CONTROL PANELSCALE: NTS4FACP BATTERY AND VOLTAGE DROP CALCULATIONSSCALE: NTS4
DEVICE & STANDARD DETAILSFA-03 of 3REVISIONSPLOT DATEPROJECT NUMBERSHEET TITLECHECKED BYDRAWN BYKMMBFARRELLI'S PIZZA - YELM
ARCH D - SIZE 36X24IN
813 W. YELM AVENUESHEET Fire Alarm | Security | CCTV | Communications
19310 North Creek Parkway, Suite 109 - Bothell, WA 98011 - info@psintegrated.com - Phone (425) 368-4201 - Fax (425) 368-4208 - License WA-PERFOSI812NO
Fire Alarm | Security | CCTV | Communications
19310 North Creek Parkway, Suite 109 - Bothell, WA 98011 - info@psintegrated.com - Phone (425) 368-4201 - Fax (425) 368-4208 - License WA-PERFOSI812NO
YELM, WASHINGTON 98597PERMIT NUMBERXXXXXXX-XXREV.TITLEDATE11022806/15/2022NICET FIRE ALARM SYSTEMSGARRICK K. YOUNGBERG, SETLEVEL IV: 90549EXP: 12/01/2023SIDEWALLTOP OF DETECTORACCEPTABLE HERE36 IN.FIXTUREFLUORESCENT LIGHTACCEPTABLE HERENEVER HERECEILING12 IN.MAXIMUMDETECTORALWAYS WITHIN 15 FT.(OF ANY SIDEWALL)MINIMUM36 IN.MINIMUM36 IN.MINIMUM36 IN.MINIMUMACCEPTABLE HERECEILINGNEVER HERENEVER HEREACCEPTABLE HERECEILINGNEVER HERESCALE: NTSTYPICAL DEVICE MOUNTING HEIGHTSSCALE: NTSTYPICAL SMOKE DETECTOR PLACEMENTMIN. 3-1/2 FT. - MAX. 4 FT.MANUAL PULL STATIONOPERATING HANDLE TO FLOOR60 IN36 INFLOORTOP OF BOX SUGGESTED MAX. 72 INTOP OF NAC POWER SUPPLYTOP OF DEVICE TO FLOORMOUNT IN ACCESSIBLE LOCATION80-96 INSTROBE (G4/G1-SERIES)LENS TO FLOOR6 INNOT WITHIN 6 IN OF CEILINGBOTTOM OF ANY CONTROL DISPLAYNOT BELOW 36 IN A.F.F.REF. ADATOP OF CONTROL DISPLAY NOTTO EXCEED 60 IN A.F.F.REF. ADAFIRE ALARM CONTROL PANEL or FIRE ALARMREMOTE ANNUNCIATOR(SEE MANUFACTURER'S SPECIFICATION SHEET)ELEVATION NOTES:THIS DETAIL IS NOT DRAWN TO SCALE. SEE SPECIFIC DEVICE INSTALLATIONSHEETS FOR MOUNTING HEIGHT OF BACK BOX.THE BOTTOM OR TOP OF INSTALLED DEVICE MAY NOT CORRESPOND TOINSTALLED BOX.910SCALE: NTSSIGA-CT2 DUAL MONITOR MODULESCALE: NTSWG4WF-HVMC OUTDOOR STROBE - WALL MOUNTED4SCALE: NTSSIGA-278 MANUAL PULL STATION2SCALE: NTSSIGA-OSD / SIGA-S4 OPTICAL SMOKE DETECTOR35SCALE: NTSG4AVRF HORN/STROBE, G4VRF STROBE - WALL MOUNT7SCALE: NTSGCAVRF HORN/STROBE - CEILING MOUNT6SIGA-278432PREVIOUSDEVICEFROM FACPORTB1TB2ACTIVEALARM/REDLED871DEVICETO NEXTNORMALLEDGRNDATAIN(+)DATAIN(-)DATA OUT(+)DATA OUT(-)(+)(-)REMOTE LED(SIGA-LED)FROMFACP ORPREVIOUSDEVICEDATA IN(-)DATA IN(+)SIGA-SB/SB4DATA OUT(-)DATA OUT(+)TO NEXTDEVICEINPUT 1DEVICEPREVIOUSFROM FACPORDATA IN(-)DATA IN(+)47KEOLOHMTB2TB1INITIATING DEVICETYP. N.O.DATA OUT(+)DATA OUT(-)TO NEXTDEVICEEOL47KOHMSIGA-CT2INPUT 2INITIATING DEVICETYP. N.O.BackplateFront coverSignal In —Signal In +Signal Out —Signal Out +WG4 GasketOptional trim skirtElectricalbox++--Horn/strobe circuitin (signal polarityshown in the activecondition)Horn/strobecircuit outShorting Clip+-+-Horn/strobe circuitin (signal polarityshown in the activecondition)Horn/strobecircuit outShorting ClipTrim Plate(optional)ShortingClip(1)(3)(4)(2)(1)(4)(3)8 7(7)++––(8)(5)4 3 2 1(6)(1) EOL resistor (PN EOL-47)(2) 22 kΩ resistor for use withpersonality code 18(3) Typical NO initiating device (4) 10VDC at 350 µA, max.(5) Red LED (alarm/active)(6) Green LED (normal)(7) Signaling line circuit(from previous device)(8) Signaling line circuit (tonext device)SCALE: NTSSIGA-CT1 SINGLE INPUT MONITOR MODULE8