22-031 Wyndstone Bldg 4 Equip SubKNIGHT FIRE PROTECTION, INC. 9702 LATHROP INDUSTRIAL DR. SW OLYMPIA, WA 98512-9188 (360) 786-8606 FAX 786-8722 LICENSE NO. KNIGHFP044LK Fire Sprinkler System Equipment Submittal Wyndstone Building 4 15025 Tahoma Blvd SE. Yelm, WA KFP Job #22-031 KFP Job #12-113 Features • cULus Listed Residential Sprinklers • Available in pendent and horizontal sidewall orientations • Decorative finishes available, including recessed escutcheons and conical concealed cover plates Product Description Model F1Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The F1Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model F1Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model F1Res residential sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, www.reliablesprinkler.com Residential Sprinkler Summary Sprinkler Model Sprinkler Identification Number (SIN) Orientation K-Factor gpm/psi1/2 (lpm/bar1/2) Thread Size NPT or ISO7-1 Installation Options Max. Coverage Area ft x ft (m x m) F1Res30 R3511 Pendent 3.0 (43)1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) F1Res49 R3516 Pendent 4.9 (71)1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1Res58 R3513 Pendent 5.8 (84)1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1Res76 R7618 Pendent 7.6 (109)3/4 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1Res30 CCP R3511 Pendent 3.0 (43)1/2 Conical Concealed 14 x 14 (4.3 x 4.3) F1Res49 CCP R3516 Pendent 4.9 (71)1/2 Conical Concealed 20 x 20 (6.1 x 6.1) F1Res58 CCP R3513 Pendent 5.8 (84)1/2 Conical Concealed 20 x 20 (6.1 x 6.1) F1Res76 CCP R7618 Pendent 7.6 (109)3/4 Conical Concealed 20 x 20 (6.1 x 6.1) F1Res44 HSW R3531 Horizontal Sidewall 4.4 (63)1/2 Recessed 16 x 20 (4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4 (63)1/2 Conical Concealed 16 x 20 (4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8 (84)1/2 Recessed 16 x 20 (4.9 x 6.1) F1Res 58 HSWX RA3533 Horizontal Sidewall 5.8 (84)1/2 Recessed 14 x 26 (4.3 x 7.9) Table A the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ min), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model F1Res Series sprinklers are listed for use in wet systems only. cULus Listed Model F1Res Series Glass Bulb Residential Sprinklers Bulletin 135 April 2021 Important Note: Model D wrench and Model GFR2 wrench are no longer compatible with this product. Model W2 (non- recessed) and Model W4 (recessed, concealed) are required. Note: Please note SIN difference between F1Res58 HSW (R3533) and F1Res58 HSWX (RA3533). Model F1Res30 Residential Pendent Sprinkler Components and Installation Dimensions Figure 1 *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Technical Specifications Style: Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model W4 (Recessed) Model F1Res30 Residential Pendent Sprinkler & Models F2 & FV Escutcheon SIN R3511 Bulletin 135 April 2021 Page 2 of 15 www.reliablesprinkler.com Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft.(m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7)8 (30)7.0 (0.48) 1 to 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3)10 (38)11.0 (0.76) 15 x 15 (4.6 x 4.6)12 (45)16.0 (1.1) 16 x 16 (4.9 x 4.9)13 (49)18.8 (1.3) Table BModel F1Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model F1Res49 Residential Pendent Sprinkler Components and Installation Dimensions Figure 2 Model F1Res49 Residential Sprinkler & Models F1, F2, & FV Escutcheons SIN R3516 Technical Specifications Style: Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass-bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F1 Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model W4 (Recessed) Bulletin 135 April 2021 Page 3 of 15 www.reliablesprinkler.com Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7)13 (49)7.0 (0.48) 1 to 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3)13 (49)7.0 (0.48) 16 x 16 (4.9 x 4.9)13 (49)7.0 (0.48) 18 x 18 (5.5 x 5.5)17 (64)12.0 (0.83) 20 x 20 (6.1 x 6.1)20 (76)16.7 (1.15) 12 x 12 (3.7 x 3.7)15 (57)9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14 (4.3 x 4.3)16 (61)10.7 (0.74) 16 x 16 (4.9 x 4.9)17 (64)12.0 (0.83) 18 x 18 (5.5 x 5.5)19 (72)15.0 (1.03) 20 x 20 (6.1 x 6.1)22 (83)20.2 (1.39) Model F1Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Table C Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res58 Residential Pendent Sprinkler & F1, F2, & FV Recessed Escutcheons SIN R3513 Technical Specifications Style: Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F1 Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model W4 (Recessed) *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res58 Residential Pendent Sprinkler Components and Installation Dimensions Figure 3 Bulletin 135 April 2021 Page 4 of 15 www.reliablesprinkler.com Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9)16 (61)7.6 (0.52) 1 to 4 inches (25 to 100 mm)18 x 18 (5.5 x 5.5)19 (72)10.8 (0.75) 20 x 20 (6.1 x 6.1)22 (83)14.4 (1.0) Model F1Res58 Residential Pendent Sprinkler Hydraulic Design Criteria Table D Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model F1Res76 Residential Pendent Sprinkler & F1, F2, & FV Escutcheons SIN R7618 Technical Specifications Style: Pendent and Recessed Pendent Threads: 3/4” NPT or ISO7-1R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F1 Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model W4 (Recessed) Model F1Res76 Residential Pendent Sprinkler Components and Installation Dimensions Figure 4 *Note: Model FV escutcheons are not for use in positively pressurized ceiling plenums. Bulletin 135 April 2021 Page 5 of 15 www.reliablesprinkler.com Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 18 x 18 (5.5 x 5.5)21 (80)7.6 (0.52)1 to 4 inches (25 to 100 mm)20 x 20 (6.1 x 6.1)23 (87)9.2 (0.63) Model F1Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Table E Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model F1Res30 CCP Conical Concealed Pendent & Model FP Recessed Escutcheon Pendent Sprinkler SIN R3511 Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 Model F1Res30 CCP and FP Recessed Pendent Sprinkler Installation Dimensions Figure 5 *Note: Model FP escutcheons and CCP cover plates are not listed for use in positively pressurized ceiling plenums. Bulletin 135 April 2021 Page 6 of 15 www.reliablesprinkler.com Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar)Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7)8 (30)7.0 (0.48)1/2 to 1 inch (13 to 25 mm)14 x 14 (4.3 x 4.3)11 (38)13.4 (0.92) Model F1Res30 CCP Pendent & FP Recessed Pendent Sprinkler Hydraulic Design Criteria Table F Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Model F1Res49 CCP Conical Concealed Pendent & Model FP Recessed Escutcheon Pendent Sprinkler SIN R3516 Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 Model F1Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions Figure 6 Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar)Deflector to Ceiling Distance 14 x 14 (4.3 x 4.3)13 (49)7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 16 x 16 (4.9 x 4.9)14 (53)8.2 (0.57) 18 x 18 (5.5 x 5.5)18 (68)13.5 (0.93) 20 x 20 (6.1 x 6.1)20 (76)16.7 (1.15) Model F1Res49 CCP Pendent and FP Recessed Pendent Hydraulic Design Criteria Table G Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Bulletin 135 April 2021 Page 7 of 15 www.reliablesprinkler.com Model F1Res58 CCP Conical Concealed Pendent & Model FP Recessed Escutcheon Pendent Sprinkler SIN R3513 Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 Figure 7Model F1Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar)Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9)16 (61)7.6 (0.52) 1/2 to 1 inch (13 to 25 mm)18 x 18 (5.5 x 5.5)19 (72)10.8 (0.75) 20 x 20 (6.1 x 6.1)22 (83)14.4 (1.0) Model F1Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Table H *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 April 2021 Page 8 of 15 www.reliablesprinkler.com Figure 8Model F1Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions Model F1Res76 CCP Conical Concealed Pendent and Model FP Recessed Escutcheon Pendent Sprinkler SIN R7618 Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 3/4” NPT or ISO7-1R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)* FP Recessed* Sprinkler Wrenches Model W4 Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar)Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9)21 (80)7.6 (0.52) 1/2 to 1 inch (13 to 25 mm)18 x 18 (5.5 x 5.5)22 (83)8.4 (0.58) 20 x 20 (6.1 x 6.1)25 (95)10.8 (0.75) Model F1Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Table I *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 April 2021 Page 9 of 15 www.reliablesprinkler.com Model F1Res44 Horizontal Sidewall Sprinkler & Models FV & F2 Recessed Escutcheon SIN R3531 Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model W4 (Recessed) Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7)12 (45)7.5 (0.52) 4 to 6 inches (100 to 150 mm) 14 x 14 (4.3 x 4.3)14 (53)10.2 (0.70) 15 x 15 (4.6 x 4.6) 15 (57)11.6 (0.80) 16 x 16 (4.9 x 4.9)16 (61)13.3 (0.92) 16 x 18 (4.9 x 5.5)18 (68)16.8 (1.16) 16 x 20 (4.9 x 6.1)23 (87)27.4 (1.89) 18 x 18 (5.5 x 5.5)19 (72)18.7 (1.29) 12 x 12 (3.7 x 3.7)14 (53)10.2 (0.7) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3)16 (61)13.2 (0.91) 15 x 15 (4.6 x 4.6)16 (61)13.2 (0.91) 16 x 16 (4.9 x 4.9)17 (64)15.0 (1.03) 16 x 18 (4.9 x 5.5)20 (76)20.7 (1.43) 16 x 20 (4.9 x 6.1)23 (87)27.4 (1.89) Model F1Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table J Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Model F1Res44 Horizontal Sidewall Sprinkler Installation Dimensions Figure 9 Bulletin 135 April 2021 Page 10 of 15 www.reliablesprinkler.com Note: (1) Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. (2) 135°F SWC Conical Concealed Plate for 155°F (68°C) sprinklers (3) 135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Ordinary Temperature Rating 155°F (68°C) Intermediate Temperature Rating 175°F (79°C)Deflector to Ceiling DistanceFlow gpm (l/min) Pressure psi (bar) Flow gpm (l/min) Pressure psi (bar) 12 x 12 (3.7 x 3.7)13 (49)8.7 (0.60)14 (53)10.2 (0.7) 4 to 6 inches (100 to 150 mm) 14 x 14 (4.3 x 4.3)14 (53)10.2 (0.7)14 (53)10.2 (0.7) 15 x 15 (4.6 x 4.6)16 (61)13.2 (0.91)– –– – 16 x 16 (4.9 x 4.9)17 (64)15.0 (1.03)– –– – 16 x 18 (5.5 x 5.5)19 (72)18.7 (1.31)– –– – 16 x 20 (4.9 x 6.1)23 (87)27.4 (1.89)– –– – 12 x 12 (3.7 x 3.7)14 (53)10.2 (0.7)– –– – 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3)15 (57)11.7 (0.81)– –– – 15 x 15 (4.6 x 4.6)17 (64)15.0 (1.03)– –– – 16 x 16 (4.9 x 4.9)18 (68)16.8 (1.16)– –– – 16 x 18 (4.9 x 5.5)20 (76)20.7 (1.43)– –– – Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table K Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. SWC SWC-2 Bulletin 135 April 2021 Page 11 of 15 www.reliablesprinkler.com Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler SIN R3531 Technical Specifications Style: Conical Concealed Sidewall Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass-bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) 175°F (79°C) (1) Cover Plates SWC Conical Concealed Plate(2) SWC-2 (Slotted) Conical Concealed Plate(3) Sprinkler Wrenches Model W4 Model F1Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions Figure 10 Model F1Res58 Horizontal Sidewall Sprinkler & Models F2 & FV Recessed Escutcheon SIN R3533 Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model W4 (Recessed) Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7)16 (61)7.6 (0.52) 4 to 6 inches (100 to 150 mm) 14 x 14 (4.3 x 4.3)18 (68)9.7 (0.66) 15 x 15 (4.6 x 4.6)19 (72)10.7 (0.74) 16 x 16 (4.9 x 4.9)21 (80)13.2 (0.91) 16 x 18 (5.5 x 5.5)25 (95)18.6 (1.28) 16 x 20 (4.9 x 6.1)29 (110)25.0 (1.72) 12 x 12 (3.7 x 3.7)22 (83)14.4 (1.0) 6 to 12 inches (150 to 300 mm) 14 x 14 (4.3 x 4.3)22 (83)14.4 (1.0) 15 x 15 (4.6 x 4.6)24 (91)17.1 (1.18) 16 x 16 (4.9 x 4.9)26 (98)20.1 (1.39) 16 x 18 (4.9 x 5.5)31 (117)28.6 (1.97) Model F1Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table L Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. Please note SIN difference between F1Res58 HSW (R3533) and F1Res58 HSWX (RA3533). Model F1Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions Figure 11 Bulletin 135 April 2021 Page 12 of 15 www.reliablesprinkler.com Model F1Res58 HSWX Horizontal Sidewall Sprinkler & Models F2 & FV Recessed Escutcheon SIN RA3533 Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2” NPT or ISO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Sensitivity Fast-response Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model W4 (Recessed) Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) Deflector to Ceiling Distance 18 x 20 (5.5 x 6.1)30 (114)26.8 (1.85) 4 to 6 inches (100 to 150 mm) 20 x 20 (6.1 x 6.1)30 (114)26.8 (1.85) 16 x 22 (4.9 x 6.7)33 (125)32.4 (2.23) 16 x 24 (4.9 x 7.3)38 (144)42.9 (2.96) 14 x 26 (4.3 x 7.9)42 (160)52.4 (3.63) 18 x 20 (5.5 x 6.1)35 (133)36.4 (2.51) 6 to 12 inches (150 to 300 mm) 16 x 22 (4.9 x 6.7)38 (144)42.9 (2.96) 16 x 24 (4.9 x 7.3)42 (160)52.4 (3.61) 14 x 26 (4.3 x 7.9)46 (174)62.9 (4.34) Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table M Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. 3. Please note SIN difference between F1Res58 HSW (R3533) and F1Res58 HSWX (RA3533). Model F1Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions Figure 12 Bulletin 135 April 2021 Page 13 of 15 www.reliablesprinkler.com Model W4 Model W2 Installation Models F1Res sprinklers are to be installed as shown in this bulletin. Model F1, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model F1Res sprinklers. Not all F1Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutcheon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models F1Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC–2) sprinklers use only the Model W4 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Installation of F1Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4” (57 mm) for F1 or F2 recessed escutcheons; or 2-5/8” (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC–2 cover plates. Install F1Res HSW sprinklers with a ceiling to deflector distance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and “Top” marking must face the ceiling. A ‘leak tight” sprinkler joint can be obtained with the following torque: • 1/2” NPT and ISO7-1R1/2: 8-18 ft-lbs (11 – 24 N-m) • 3/4” NPT and ISO7-1R3/4: 14-20 ft-lbs (19 – 27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Table N Standard Finishes Special Application Finishes Sprinkler(1)F1, F2. FV, FP(3), Escutcheons CCP, SWC (Conical) Cover Plates (1)Sprinkler (1)F1, F2. FV, FP(3), Escutcheons CCP, SWC (Conical) Cover Plates (1) Bronze Brass --Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White Polyester (2) White Polyester White Paint Black Polyester (2) Black Polyester Black Paint ------Custom Color Polyester Custom Color Polyester Custom Color Paint ------Electroless Nickel PTFE (2)---- Notes: (1) Paint or any other coating applied over the factory finish will void all approvals and warranties. (2) cULus Listed Corrosion Resistant. (3) The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Finishes The Model W4 wrench includes two sets of jaws. One set of jaws is equivalent to a Model GFR2 wrench and the other set of jaws is equivalent to a Model W1 wrench. Use the smallest of the two sets of jaws that will fit on the sprinkler’s wrench flats. The Model W4 wrench is used in conjunction with the installer’s nominal 1/2” square drive ratchet and nominal 5” (125mm) long extension (not provided) as shown in Figure 13. Model W4 Wrench Installation Example Figure 13 Bulletin 135 April 2021 Page 14 of 15 www.reliablesprinkler.com P/N 9999970235Maintenance Reliable Model F1Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC–2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler • Model (See Table A) • Temperature Rating • Threads (NPT or ISO7-1) • Finish (See Table N) Escutcheon or Cover Plate • Model • Finish (See Table N) Sprinkler Wrench • Model W2 (Pendent and HSW) • W4 (Recessed and Concealed) Note: Please note SIN difference between F1Res58 HSW (R3533) and F1Res58 HSWX (RA3533). Bulletin 135 April 2021 Page 15 of 15 www.reliablesprinkler.com Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR56 Dry K5.6 (80 metric) Quick-Response, Standard Spray Sprinklers Bulletin 157 February 2021Bulletin 157 February 2021 Features 1. Available in the following configurations: • Pendent with standard escutcheon • Pendent with Model HB extended escutcheon • Pendent with Model FP recessed escutcheon • Pendent with Model F1 recessed escutcheon • Concealed Pendent with Model CCP cover plate • Horizontal Sidewall with Standard escutcheon • Horizontal Sidewall with Model HB extended escutch- eon • Horizontal Sidewall with Model FP recessed escutch- eon (FM Standard Response) • Horizontal Sidewall with Model F1 recessed escutch- eon (FM Standard Response) • Upright 2. Available with 1” NPT, ISO7-1R1, 3/4” NPT, or ISO7- 1R3/4 inlet fitting. 3. 3/4” NPT inlet fittings permit replacement of older 3/4” inlet dry sprinklers without changing to a larger sprinkler fitting. 4. Sprinklers, escutcheons, and cover plates are available in a wide variety of standard and special application fin- ishes. 5. White polyester, black polyester, and Electroless Nickel PTFE (ENT) finish sprinklers are cULus Listed as Corro- sion Resistant. 6. Available with cULus Listed 250 psi (17.2 bar) pressure rating for Dry Pendent and select HSW configurations. FM Approved for 175 psi (12 bar). Product Description Model F3QR56 Dry sprinklers are quick-response, standard coverage sprinklers with a nominal K-Factor of 5.6 (80 metric). Available in Dry Pendent, Dry Horizontal Sidewall, and Dry Up- right configurations, Model F3QR56 Dry sprinklers all use a 3 mm glass bulb operating element. See the Temperature Rat- ings table in this Bulletin for available temperature ratings. Mod- el F3QR56 Dry sprinklers are intended for installation on wet- pipe, dry-pipe, or preaction sprinkler systems in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and other applicable installation standards. Model F3QR56 Dry Pendent and Sidewall sprinklers are avail- able with a variety of escutcheon options as illustrated in Figs. 1 through 3 and Figs. 5 through 9. In addition, Model F3QR56 Dry Pendent sprinklers are also available with the Model CCP conical concealed cover plate as illustrated in Fig. 4. Available sprinkler, escutcheon, and cover plate finishes are identified in the Finishes table in this Bulletin. The Model F1 escutcheon, Model FP escutcheon, and Model CCP cover plate are the only recessed escutcheons and cover plate listed for use with Model F3QR56 Dry sprinklers; the use of any other recessed escutch- eon or cover plate with Model F3QR56 Dry sprinklers will void all guarantees, warranties, listings and approvals. Concealed (See Fig. 4) Recessed FP Pendent (See Fig. 3) Recessed F1 Horizontal Sidewall (See Fig. 9) Horizontal Sidewall (See Fig. 6) Pendent (See Fig. 1) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent / HB (See Fig. 2) Horizontal Sidewall / HB (See Fig. 7) Upright (See Fig. 10) Inlet fittings are available with 1” NPT, ISO 7-1R1, 3/4” NPT, or ISO7-1R3/4 threads. Sprinklers with 3/4” NPT and ISO7-1R3/4 inlet fittings are intended primarily for replacement of existing 3/4” or ISO7-1R3/4 inlet dry sprinklers, but may also be used in new installations. 2. See the Available Configurations, Listings, and Approvals table in this Bulletin for further information on Model F3QR56 Dry sprinklers. Available Configurations, Listings, and Approvals Sprinkler Model Escutcheon or Cover Plate Available Length (See Figs. 1-9) Listings and Approvals(1) Inlet Threads Sprinkler Identification Number (SIN) F3QR56 Dry Pendent Standard Escutcheon 2” to 36” (50 to 900 mm) cULus, NYC 3/4” NPT or ISO7-1R3/4 R5714 HB Extended Escutcheon 3-1/2” to 36” (90 to 900 mm) F1 Recessed Escutcheon FP Recessed Escutcheon CCP Cover Plate Standard Escutcheon 2” to 48” (50 to 1200 mm) cULus, FM, NYC 1” NPT or ISO7-1R1 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon FP Recessed Escutcheon CCP Cover Plate F3QR56 Dry Horizontal Sidewall Standard Escutcheon 2” to 48” (50 to 1200 mm) cULus(2), NYC(2)3/4” NPT or ISO7-1R3/4 R5734 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon FP Recessed Escutcheon Standard Escutcheon 2” to 48” (50 to 1200 mm)cULus(2), FM(3), NYC(2) 1” NPT or ISO7-1R1 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon 3-1/2” to 48” (90 to 1200 mm) cULus(2), FM(3)(4), NYC(2)FP Recessed Escutcheon F3QR56 Dry Upright N/A 5” to 48” (127 to 1200 mm)cULus(2)1” NPT or ISO7-1R1 R5724 (1) For available temperature ratings and finishes see the Temperature Ratings and Finishes tables, respectively, in this Bulletin. (2) cULus Listing and NYC for Light Hazard and Ordinary Hazard only. (3) FM Approved for Light Hazard only. (4) Model F3QR56 Dry Horizontal Sidewall with Model F1 or Model FP recessed escutcheon are FM Approved as Standard Response. Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. 1. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) 2. Certified by FM Approvals (FM) 3. Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Nominal K-Factor: 5.6 gpm/psi1/2 (80 L/min/bar1/2) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F3QR56 Dry Pendent cULus, NYC See note below 250 psi (17.2 bar) FM See note below 175 psi (12 bar) F3QR56 Dry Horizontal Sidewall cULus, NYC 4” to 6 “250 psi (17.2 bar) 4” to 12”175 psi (12 bar) FM See note below 175 psi (12 bar) F3QR56 Dry Upright cULus See note below 175 psi (12 bar) Note: Deflector distance to be in accordance with applicable NFPA, FM, or other agency requirements. Information is provided only when additional clarification is necessary. Temperature Classification Glass Bulb Color Sprinkler Temperature Rating Cover Plate Temperature Rating Maximum Ceiling Temperature Listings and Approvals(1) Ordinary Orange 135°F (57°C)135°F (57°C)100°F (38°C)cULus, FM, NYCRed155°F (68°C) Intermediate Yellow 175°F (79°C)165°F (74°C)150°F (66°C)cULus, NYC Intermediate Green 200°F (93°C)165°F (74°C)150°F (66°C)cULus, FM, NYC High Blue 286°F (141°C)None 225°F (107°C)cULus, FM(2), NYC 165°F (74°C)150°F (66°C)cULus, NYC (1) For listed and approved sprinkler, escutcheon, and inlet configurations see the Available Configurations, Listings, and Approvals table in this Bulletin. (2) High temperature classification is FM Approved with Standard and Model HB escutcheons only. Finishes4 Component Sprinkler Escutcheon(1)Cover Plate Standard Finishes Bronze Brass(3)White Paint White Polyester(2)White Polyester ChromeChromeChrome Special Application Finishes Electroless Nickel PTFE(2)Type 316 Stainless Steel Satin Chrome Black Paint Custom Color Paint Black Plating Black Polyester(2)Black Polyester Custom Color Polyester Customer Color Polyester (1) Standard and Model HB escutcheons are supplied with both the can and escutcheon finished. Model F1 escutcheons are supplied with both the collar and es- cutcheon finished. Model FP escutcheons are supplied with the escutcheon finished; the cup is galvanized or stainless steel with no further finish. (2) cULus Listed as a Corrosion Resistant Sprinkler. (3) Brass finish available for standard, Model F1, and Model FP escutcheons only. (4) Dry upright sprinkler available in standard bronze only. 3. 4. Note: The sprinkler can protrudes ¼” when escutcheon is in nominal position. Escutcheon adjustment provides -¼” (-6mm) to +1¼” (+32mm) “A” dimen- sion adjustment range. Fig. 1 Model F3QR56 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5714) “A” Dim.2” to 48” (51mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 2” to 36” (51mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Sprinkler Guard: Model C2 Model F3QR56 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5714) “A” Dim.3½” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: The sprinkler can protrudes 1¼” when escutcheon is in nominal position. Escutcheon adjustment provides -½” (-12.7mm) to +½” (+12.7mm) “A” dimension adjustment range. Fig. 2 5. Sprinkler Guard: Model C2 Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space above. Fig. 3 6. Model F3QR56 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN R5714) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Model F3QR56 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN R5714) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have positive pressure in the space above. Fig. 4 7. Model F3QR56 Dry Pendent Sprinkler with Model F1 Recessed Escutcheon (SIN R5714) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections. Fig. 5 8. Note: The sprinkler can protrudes ¼” when escutcheon is in nominal position. Escutcheon adjustment provides -¼” (-6mm) to +1¼” (+32mm) “A” dimen- sion adjustment range. Fig. 6 9. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Standard Escutcheon (SIN R5734) “A” Dim.2” to 48” (51mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 2” to 36” (51mm to 914mm) in 1/4” (6mm) increments for 3/4” connections 10. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN R5734) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: The sprinkler can protrudes 1¼” when escutcheon is in nominal position. Escutcheon adjustment provides -½” (-12.7mm) to +½” (+12.7mm) “A” dimension adjustment range. Fig. 7 11. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon (SIN R5734) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: Do not install the Model F3QR56 Dry Horizontal Sidewall sprinkler with the Model FP escutcheon in walls which are positively pressurized with respect to the protected space. Fig. 8 12. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon (SIN R5734) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Fig. 9 13. Model F3QR56 Dry Upright (SIN 5724) Order Dimensions 5” to 48” (127 mm to 1219 mm) Fig. 10 Fig. 11 14. Fig. 12 15. Fig. 14 - Model XLO2 Wrench Fig. 13 - Model F3R Wrench 16. Fig. 15 17. Installation Instructions When used on wet pipe systems, Reliable Model F3QR56 dry sprinklers may be installed in ductile or malleable cast iron threaded tees, or CPVC tees and adapters upon verification that the sprinkler inlet fitting does not interfere with the interior of the fitting (see Figure 12). When used on dry pipe systems, Reliable Model F3QR56 dry pendent sprinklers MUST ONLY BE installed in the outlets of ductile or malleable cast iron threaded tees on horizontal pipe such that the inlet of the sprinkler protrudes above the bottom level of the pipe. When used on dry pipe systems, Reliable Model F3QR56 dry sidewall and dry upright sprinklers may be installed in duc- tile or malleable cast iron threaded tees, or CPVC tees and adapters upon verification that the sprinkler inlet fitting does not interfere with the interior of the fitting (see Figure 12). DO NOT install Reliable dry sprinklers into elbows or cou- plings, welded outlets, mechanical tees, or gasket sealed CPVC fittings. Dry sprinklers connected to wet pipe systems must be in- stalled as indicated in Figure 11 and as required by NFPA 13 with the Exposed Minimum Barrel Length located in a heated area. An orange protective clip is factory installed on the sprinkler to protect the glass bulb thermal element from damage. The clip should remain in place during installation of the sprinkler and be removed when the sprinkler system is placed in service. Sprinklers with 3/4” NPT and ISO7-1R3/4 inlets are supplied with a protective cap on the inlet that must be removed before installation. Use the following steps for installation: 1. Cut a hole in the wall or ceiling directly in-line with the outlet of the fitting. See the Installation Data table for the recommended hole diameter based on the escutcheon or cover plate option selected. 2. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler’s inlet fitting. 3. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Mod- el F3R wrench is designed to be inserted into the groves in the sprinkler’s wrench boss as shown in Fig. 13. The Model XLO2 wrench is designed to fit into the cup and engage the wrench boss as shown in Fig. 14. Do NOT wrench any part of the sprinkler assembly other than the wrench boss. When inserting or removing the wrench from the sprinkler, care should be taken to prevent dam- age to the sprinkler. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to maximum installation torque is 22 - 30 lb-ft (30 – 40 N-m) for 1” NPT and ISO7-1R1 sprinklers, and 14 - 20 lb-ft (19 – 27 N-m) for 3/4” NPT and ISO7-1R3/4 sprinklers. 3a. Alternatively, where access to the outer tube of the sprinkler is available, the Model F3QR56 Dry sprin- kler may be installed using a pipe wrench. The pipe wrench shall only be permitted to interface with the galvanized steel outer tube portion of the sprinkler (Item #8 in Fig. 15). Do NOT wrench any other por- tion of the sprinkler assembly. A pipe wrench can in- stall the sprinkler into the fitting with a large amount of torque; consideration should be given to the need for future removal of the sprinkler because the instal- lation torque will have to be matched or exceeded to remove the sprinkler. The recommended minimum to maximum installation torque is 22 - 30 lb-ft (30 – 40 N-m) for 1” NPT and ISO7-1R1 sprinklers, and 14 - 20 lb-ft (19 – 27 N-m) for 3/4” NPT and ISO7-1R3/4 sprinklers. 4. Standard and Model HB escutcheons can be installed by slipping the escutcheon over the can until the es - cutcheon is seated against the ceiling or wall. Model F1 escutcheons are installed by pressing the escutcheon onto the collar until the escutcheon is seated against the ceiling or wall. The Model FP escutcheon is installed by pressing or threading the escutcheon into the cup by hand; the escutcheon can be tightened against the ceiling or wall by turning the escutcheon in a clockwise direction and removed by turning the escutcheon in a counter-clockwise direction. To install the Model CCP cover plate, first remove the protective clip. Install the Model CCP cover plate on the sprinkler by pressing or threading the cover plate into the cup by hand; the cov- er plate can be tightened against the ceiling by turning the cover plate in a clockwise direction and removed by turning the cover plate in a counter-clockwise direction. 5. Remove the orange protective clip when placing the sprinkler system in service. 18. 4. Inlet Fitting: [Long – Standard Inlet Fitting][Short “PL” – Wet Pipe Systems only] 5. Sprinkler Temperature Rating: See Temperature Ratings table 6. Sprinkler Finish: See Finishes Table 7. Escutcheon/Cover Plate Finish: See Finishes Table 8. Length: *For dry pendents and dry sidewalls: “A” Dimension is from face of tee to face of finished ceiling or wall in 1/4” (6mm) increments. See Fig. 1 through Fig. 9. *For dry uprights: Order dimension is from face of tee to top of deflector in 1/4” (6mm) increments. See Fig. 10. Notes: 1. For Dry Upright, customer is responsible for determining the correct deflector distance from structure above. 2. Length is based on normally gauged pipe thread “make-up” of .600” (15mm) per ANSI B2.1 (approximately 7-1/2 threads). Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 02/21 P/N 9999970175 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Installation Data Sprinkler Model Escutcheon or Cover Plate Suggested Hole Diameter in Wall or Ceiling Installation Wrench Required Centerline of Sprinkler Tube/Inlet to Finished Ceiling Vertical Dimension* F3QR56 Dry Pendent Standard Escutcheon 2-1/8” (54 mm)F3R Not Applicable HB Extended Escutcheon 2-1/2” (64 mm)F3R F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 FP Recessed Escutcheon 2-1/2” (64 mm)XLO2 CCP Cover Plate XLO2 F3QR56 Dry Horizontal Sidewall Standard Escutcheon 2-1/8” (54 mm)F3R 4-5/8” to 12-5/8” (118 mm to 321 mm)HB Extended Escutcheon 2-1/2” (64 mm)F3R F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 cULus, NYC 4-5/8” to 6-5/8” (118 mm to 168 mm)FP Recessed Escutcheon 2-1/2” (64 mm)XLO2 F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 FM 4-5/8” to 12-5/8” (118 mm to 321 mm)FP Recessed Escutcheon 2-1/2” (64 mm)XLO2 F3QR56 Dry Upright N/A 1-1/2” (38mm)F3R Not Applicable *Note: Based on 5/8” (16 mm) centerline of sprinkler tube/inlet to defector vertical distance. Maintenance The Model F3QR56 Dry Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Specify: 1. Sprinkler: [Model F3QR56 Dry Pendent SIN R5714] [Model F3QR56 Dry Horizontal Sidewall SIN R5734] [Model F2QR Dry Upright SIN R5724] 2. Escutcheon/Cover Plate: [None][Standard escutcheon] [Model HB extended escutcheon][Model F1 recessed escutcheon][Model FP recessed escutcheon][Model CCP cover plate – pendent only] 3. Inlet Threads: [1” NPT][ISO7-1R1][3/4” NPT][ISO7- 1R3/4] Pipe Clamps Fig. 28 ® "Stand -Off" Hanger & Restrainer f®r CPUC Plastic Pipe & IPS Steel Pipe ** Size Range: — 3/4' (20mm) through 2' (50mm) Material: — Steel, Pre -Galvanized Function: — Designed to be used as a hanger and restrainer for CPVC piping where the 'stand-off' design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. • The 'Stand -Off' design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attaches easily to wood structure with two hex head self -threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16' (7.9mm) extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge (1.024mm) with (2) 1/4' x 1' tek type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals: — Underwriters Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4' x 1' tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8' (9.5mm) composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by: — Figure number and pipe size. Pat. # 7,455,268, Pat. # 7,832,248 ** With reduced spacing, consult factory. Fig. 27B (1) Required High Side of Hanger Application Hanger Application Fig. 27B Fli (2) Required Li Hanger and Restraint Application B -Line by 0 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 40 Fire Protection Solutions Pipe Size A B C Max Hanger Approx. Spacing Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) R. (m) lbs. (kg) 28-3/4 3/4' (20) 31/32' (77.0) 2' (50.8) 31/2' (88.9) 51/2 (1.67) 18 (8.1) 28-1 V (25) 35/16" (84.1) 23/16' (55.6) 31/2' (88.9) 6 (1.83) 21 (9.5) 28-11/4 11/4' (32) 35/8' (92.1) 23/8' (60.3) 31/2' (88.9) 61/2 (1.98) 23 (10.4) 28-11/2 11/2' (40) 4' (101.6) 21/2' (63.5) 31/2' (88.9) 7 (2.13) 31 (14.0) 28-2 2' (50) 41/2' (114.3) 211/16' (68.3) 35/8' (92.1) 8 (2.44) 34 (15.4) B -Line by 0 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 40 Fire Protection Solutions Pipe ClampsAll dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Clamps 34 Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Double Fastener Strap Side Mounted (Cooper B-Line B3183) Size Range:3/4" (20mm)thru 2" (50mm)CPVC pipe Material:Pre-Galvanized Steel Function:Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm)steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features:Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish:Pre-Galvanized Order By:Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. C A B B CPVC Max. Hanger Fastener Hex Approx. Pipe Size ABCSpacing Head Size Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 24-3/4 3/4"(20)25/16"(58.7)15/32"(27.8)13/16"(30.2)51/2 (1.67)5/16"(7.9)9 (4.1) 24-1 1"(25)25/8"(66.7)15/16"(33.3)13/16"(30.2)6 (1.83)5/16"(7.9)9 (4.1) 24-11/4 11/4"(32)3"(76.2)11/2"(38.1)13/16"(30.2)61/2 (1.98)5/16"(7.9)11 (5.0) 24-11/2 11/2"(40)31/4"(82.5)15/8"(42.3)13/16"(30.2)7 (2.13)5/16"(7.9)12 (5.4) 24-2 2"(50)311/16"(93.7)127/32"(43.6)13/16"(30.2)8 (2.44)5/16"(7.9)15 (6.8) Fig. 25 - Surge Restrainer Size Range:— One size fits 3/4"(20mm)thru 2"(40mm)pipe. Material:— Pre-Galvanized Steel Function:— Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals:— Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL)and Canada (cUL). Finish:Pre-Galvanized Order By:Figure number and band hanger, size from 3/4"(20mm)thru 2"(40mm). Patent #5,344,108 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 43 www.tolco.com Revision 1/11/2011 Fig. 28M - Offset Hanger and Restrainer for CPVC Plastic Pipe and IPS Pipe Size Range — 3/4" thru 1-1/4" Material — Carbon Steel, Pre-Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping or steel piping where the “stand-off” design will ease installation by eliminating the need for wood blocking. Features — • Flared edge design protects CPVC pipe from any rough or abrasive surfaces • Unique snap-on design holds pipe firmly in place and allows retrofit type of installation • The “Stand-Off” design eliminates the need for wood block extension • Can be installed on horizontal or vertical piping regardless of mounting surface orientation • Attaches easily to wood structure with two hex head self-threading screws furnished with product • Installs easily using rechargeable electrical driver with 5/16” extension socket eliminating impact tool damage to pipe • Attaches easily to steel, minimum 18 gauge with (2) 1/4” x 1” tek type self drilling tapping screws • cULus Listed as a hanger and a restrainer for fire sprinkler piping Installation Note — When installed in wood structural member and threads from the #10 x 1" screws are exposed, use FIG. 27B speed nut to secure Approvals — Underwriters’ Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fas- teners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28M satisfies the UL vertical restraint requirements where needed. Order By — Figure number and pipe size A C B RESTRAINT Patent #7,744,042 RESTRAINT Dimensions • Weights Max. Spacing Pipe required per Approx Size A B C NFPA 13 for Wt./100 CPVC plastic pipe 3/4 2 3/16 3-5/16 5’-6” 9 1 2-1/8 3/16 3-1/2 6’-0” 12 1-1/4 2-5/16 3/16 3-1/2 6’-6” 13 HANGER APPLICATIONDETAIL A TOLCO FIG. 27B(1) REQUIREDHIGH SIDEOF HANGER APPLICATIONHANGER AND RESTRAINT A TOLCO FIG. 27B(2) REQUIRED The Series 705 Butterfly Valve features a weatherproof actuator housing Approved for indoor or outdoor use, a ductile iron body and disc with EPDM seats. Designed for fire protection services only. Victaulic FireLock Series 705 Butterfly Valve is cULus Listed, LPCB Listed, FM and VdS Approved for 300 psi/2068 kPa service. Contact Victaulic for details of agency approvals. APPROVALS AND LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve cULus FM VdS LPCB 2"/50mm up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 2 1/2"/65mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3"/80mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 4"/100mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 5"/125mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 6"/150mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 8"/200mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10"/250mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12"/300mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 10.81_1 FireLock ® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR 10.81IPS CARBON STEEL PIPE – FIRE PROTECTION VALVES JOB/OWNER CONTRACTOR ENGINEER System No. __________________________Submitted By ________________________Spec Sect ____________ Para __________ Location ____________________________Date ________________________________Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_E MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536, grade 65-45-12 End Face, 2 – 6"/50 – 150 mm: Ductile iron conforming to ASTM A-536, grade 65-45-12 Seal Retainer, 8 – 12"/200 – 300 mm: Ductile iron conforming to ASTM A-536, grade 65-45-12 Coating: Black alkyd enamel Disc: Ductile iron conforming to ASTM A-536, grade 65-45-12, with electroless nickel coating con- forming to ASTM B-733 Seat: • Grade “E” EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless Steel with TFE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: • 2 - 8"/50 - 200mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing • 10 - 12"/250 - 300mm: Steel worm and cast iron quadrant gear, in a cast iron housing 10.81_2 FireLock ® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR 10.81IPS CARBON STEEL PIPE – FIRE PROTECTION VALVES www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_E DIMENSIONS – Size Dimensions – Inches/millimeters Size Outside Diameter End to End A B C D E F G DIA H J 2"2.375 4.25 2.28 6.41 ——4.00 4.22 4.50 2.12 60.3 mm 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 2½"2.875 3.77 2.28 7.54 ——4.00 4.22 4.50 1.77 73 mm 73.0 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3.000 3.77 2.28 7.54 ——4.00 4.22 4.50 1.77 76.1 mm 76.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3"3.500 3.77 2.53 7.79 ——4.50 4.22 4.50 1.77 88.9 mm 88.9 95.8 64.3 197.9 114.3 107.2 114.3 45.0 4.250 4.63 2.88 8.81 ——5.50 4.22 4.50 2.20 108 mm 108.0 117.6 73.2 223.8 139.7 107.2 114.3 55.9 4"4.500 4.63 2.88 8.81 ——5.50 4.22 4.50 2.20 114.3 mm 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 5.250 5.88 3.35 10.88 ——6.56 6.19 6.30 2.58 133 mm 133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 5.500 5.88 3.35 10.88 ——6.56 6.19 6.30 2.58 139.7 mm 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5"5.563 5.88 3.35 10.88 ——6.56 6.19 6.30 2.58 141.3 mm 141.3 149.4 85.1 276.4 166.6 157.2 160.0 65.5 6.250 5.88 3.84 11.38 0.41 10.4 7.52 6.19 6.30 2.58 159 mm 159.0 149.4 97.5 289.1 —191.0 157.2 160.0 65.5 6.500 5.88 3.84 11.38 —0.41 10.4 7.52 6.19 6.30 2.58 165.1 mm 165.1 149.4 97.5 289.1 191.0 157.2 160.0 65.5 6"6.625 5.88 3.84 11.38 0.41 10.4 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 —191.0 157.2 160.0 48.3 8"8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 mm 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10"10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 —273 mm 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12"12.750 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 —323.9 mm 323.9 165.1 186.9 422.7 58.4 71.1 362.0 205.7 228.6 F G E A D ØH B C J F G E A D ØH B C J Note: Optional ½"/15mm tap available. Contact Victaulic for details. 10.81_3 FireLock ® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR 10.81IPS CARBON STEEL PIPE – FIRE PROTECTION VALVES www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_E PERFORMANCE The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/ meters of straight pipe. Size Size Nominal Size Inches mm Actual Outside Diameter Inches mm Equiv. Feet/m of Pipe Nominal Size Inches mm Actual Outside Diameter Inches mm Equiv. Feet/m of Pipe 2 2.375 6 6 6.625 14 50 60.3 1.8 150 168.3 4.2 2 ½2.875 6 159 mm 159 mm 14 65 73.0 1.8 4.3 76.1 mm 3.000 6 165.1 mm 6.500 14 76.1 1.8 165.1 4.2 3 3.500 7 8 8.625 16 80 88.9 2.1 200 219.1 4.9 4 4.500 8 10 10.750 18 100 114.3 2.4 250 273.0 5.5 108 mm 108 mm 8 12 12.750 19 2.4 300 323.9 5.8 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 5.500 12 139.7 3.7 10.81_4 FireLock ® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR 10.81IPS CARBON STEEL PIPE – FIRE PROTECTION VALVES www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_E PERFORMANCE CV values for flow of water at +60°F/+16°C with a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for CV Values: Size CV Size CV Size CV Nominal Size Inches mm Actual Outside Diameter Inches mm (Full Open) Nominal Size Inches mm Actual Outside Diameter Inches mm (Full Open) Nominal Size Inches mm Actual Outside Diameter Inches mm (Full Open) 2 2.375 170 5 5.563 1200 8 8.625 340060.3 125 141.3 200 219.1 2 ½2.875 260 133 mm 133 mm 1200 10 10.750 58006573.0 250 273.0 76.1 mm 3.000 260 139.7 mm 5.500 1200 12 12.750 900076.1 139.7 300 323.9 3 3.500 440 6 6.625 18008088.9 150 168.3 4 4.500 820 159 mm 159 mm 1800100114.3 108 mm 108 mm 820 165.1 mm 6.500 1800165.1 Formulas for KV Values: Size KV Size KV Size KV Nominal Size Inches mm Actual Outside Diameter Inches mm (Full Open) Nominal Size Inches mm Actual Outside Diameter Inches mm (Full Open) Nominal Size Inches mm Actual Outside Diameter Inches mm (Full Open) 2 2.375 147 5 5.563 1040 8 8.625 294060.3 125 141.3 200 219.1 2 ½2.875 225 133 mm 133 mm 1040 10 10.750 50206573.0 250 273.0 76.1 mm 3.000 225 139.7 mm 5.500 1040 12 12.750 779076.1 139.7 300 323.9 3 3.500 380 6 6.625 15608088.9 150 168.3 4 4.500 710 159 mm 159 mm 1560100114.3 108 mm 108 mm 710 165.1 mm 6.500 1560165.1 10.81_5 FireLock ® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR 10.81IPS CARBON STEEL PIPE – FIRE PROTECTION VALVES www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_E SWITCH AND WIRING 1. The supervisory switch contains two single pole, double throw, pre-wired switches. 2. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC 3. Switches supervise the valve in the “OPEN” position. 4. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per termi- nal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. 5. A #14 insulated ground lead (green) is provided. Switch #1 = S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction S1 {Normally Closed: (2) Blue Common: (2) Yellow S2 {Normally Closed: Blue with Orange Stripe Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe CONDUIT ½" NPT CONDUIT CONNECTORS UL LISTEDJUNCTION BOX WIRE NUTS FIRE ALARM CONTROL PANEL SUPERVISORY CIRCUIT N.C.NO.COM. TO END-OF-LINE RESISTOR, OR NEXT INDICATOR BELL OR HORNVOLTAGE SOURCE Switch 1: 2 leads per terminal Switch 2: 1 lead per terminal SWITCH CONTACT RATING: 10A AT 125 AND 250VAC, 0.5A AT 125 VDC, 0.25 AT 250 VDC S1 S2 NOTE: The above diagram shows a connection between the common terminal (yellow – S1 and yellow-with-orange stripe – S2) and the normally closed terminal (blue – S1 and blue-with-orange stripe – S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). Only S1 (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). 10.81_6 FireLock ® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR 10.81IPS CARBON STEEL PIPE – FIRE PROTECTION VALVES www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_E WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE Reference should always be made to the installation sheet included with the valve. Verify you have the latest revision by visiting our website at www.victaulic.com. Further reference can be found in the I-100 Victaulic Field Installation Handbook. INSTALLATION 10.81 FireLock ® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR 10.81IPS CARBON STEEL PIPE – FIRE PROTECTION VALVES For complete contact information, visit www.victaulic.com 10.81 5662 REV E UPDATED 04/2013 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN USA PAGE 1 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD MFG. #5401146 - REV M 11/15 UL, CUL and CSFM Listed, FM Approved, LPCB Approved, For CE Marked (EN12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL • Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. Ordering Information Nominal Pipe Size Model Part Number 2"DN50 VSR-2 1144402 2 1/2"DN65 VSR-2 1/2 1144425 3"DN80 VSR-3 1144403 3 1/2"-VSR-3 1/2 1144435 4"DN100 VSR-4 1144404 5"-VSR-5 1144405 6"DN150 VSR-6 1144406 8"DN200 VSR-8 1144408 Specifications subject to change without notice. Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Waterflow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com General Information The Model VSR is a vane type waterflow switch for use on wet sprinkler systems. It is UL Listed for use on a steel pipe; schedules 5 through 40, sizes 2" - 6" and is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterflow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Important: This document contains important information on the installation and operation of the VSR waterflow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. PRINTED IN USA MFG. #5401146 - REV M 11/15 PAGE 2 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterflow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. ADAPTER USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DN50 ONLY ADAPTER 50mm 20mm ±2mm MAX. DWG# 1146-1F Fig. 1 NOTE: For copper or plastic pipe use Model VSR-CF. Retard Adjustment The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms (Flowing water activates device in one direction only.) DO NOT LEAVE COVER OFF FOR AN EXTENDED PERIOD OF TIME TIGHTEN NUTS ALTERNATELY MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOWDIRECTION OF WATERFLOW Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts TorqueLightwallSchedule 10 (UL)Schedule 40 (UL)BS-1387 (LPC)DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 + .125/- .062 33.0 ± 2.0 20 27 VSR-2 1/2 2.5 -2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 ---- VSR-2 1/2 -DN65 3.000 76.1 ------0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00 ± .125 50.8 ± 2.0 VSR-3 1/2 3.5 -4.000 101.6 --0.120 3.05 0.226 5.74 ---- VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 -5.563 141.3 --0.134 3.40 0.258 6.55 ---- VSR-6 6 DN150 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 --0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm. If an alarm is not desired, a qualified technician should disable the alarm system. PRINTED IN USA PAGE 3 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD MFG. #5401146 - REV M 11/15 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. DWG 1146-4 Fig. 2 Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 4 Switch Terminal Connections Clamping Plate Terminal Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector’s test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 6 Mounting Dimensions DWG. 1146-14 3.50 in (89.0 mm) 2.34 in (59.4 mm) PIPE DIA. + 5.25 in (+ 133.4 mm) 5.56 in (141.2 mm)2.00 in (50.8 mm) U-BOLT NUT U-BOLT WASHER PIPE SADDLE PIPE PLASTIC PADDLE U-BOLT NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR DN 50 – DN 65 2–2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR DN 80 – DN 200 3–8 in DWG 1146-15 GREEN GROUND SCREWS Fig. 7 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. Notes: 1. The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. For supervised circuits, see “Switch Terminal Connections” drawing and warning note (Fig. 4). Fig. 5 Typical Electrical Connections LOAD TO BELLNEUTRAL FROM BELL CONNECTOR EOL (End Of Line Resistor) BELLNEUTRAL FROM BREAKER BREAKER LINE FROM BREAKER NOTE: When connecting to a UL Listed control panel, use the panel’s resistor value for circuit supervision. PRINTED IN USA MFG. #5401146 - REV M 11/15 PAGE 4 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Removal of Waterflow Switch • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. Fig. 8 Retard/Switch Assembly Replacement (See Fig. 8) The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell (if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re-install the (2) original mounting screws. 8. Reconnect all wires. Perform a flow test and place the system back in service. Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 8). There is no maintenance required, only periodic testing and inspection. DWG# 1146-10 BREAK OUT THIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. DO NOT REMOVE (2) RETARD HOUSING SCREWS REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE RETARD/SWITCH ASSEMBLY (2) ORIGINAL MOUNTING SCREWS (2) LOCATING PINS (2) LOCATING PIN BOSSES IN BASE BASE data sheet The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM Fire Sprinkler Pressure Gauges 0-300 psi water 0-300 psi air 0-300 psi air/water Application:Fluid medium which does not clog connection port or corrode copper alloy. Specifically designed for the fire sprinkler industry. Size:4” (100 mm) Accuracy ± 3/2/3% of span - 1½" (ASME B40.1 Grade B) Working Range Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value Operating Temperature Ambient: -40°F to 140°F (-40°C to 60°C) Media: max. 140°F (+60°C) Temperature Error Additional error when temperature changes from reference temperature of 68°F (20°C) +0.4% for every 18° F (10°C) rising or falling. Percentage of span. Standard Features Connection Material: copper alloy Lower mount (LM) - not available for 1½" size 1/4" NPT limited to wrench flat area Bourdon Tube:Material: copper alloy C-type Movement:Copper alloy, silicone dampened Dia:White plastic with stop pin - black &red lettering Pointer: Black aluminum Case: Black polycarbonate Approvals UL listed (UL-393) FM approved Standard Scale PSI Window Acrylic, ultrasonically welded to case Standard Series • Type 110.10sp Order Options water air/water air CERTIFICATE OF COMPLIANCE ACCURACY STATEMENT WIKA Instrument Corporation certifies that the products specked herein have been manufactured to the ASME 1340.100 accuracy grade listed. CUSTOMER: ALLIED RUBBER & GASKET CO. 5400 SOUTH 66 STREET FORT SMITH, AR 72903 CUSTOMER P.O. NO.: 26482 ORDER NO.: 865505 ORDER DATE: 9/25/08 CUSTOMER PIN: 6510160 WIKA PIN: 4276176 - Pressure and Temperature Measurement WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville, Georgia 30043 Tei. 770-513-8200 Fax 770-338118 www.wtka.com info@wika.com DESCRIPTION: . 111 _I OSP 4 300P81 114 L AlR/WATER ARGCO GAUGE RANGE(S): 300PSI QUANTITY: 6000 ACCURACY GRADE: +1- 31213% OF SPAN AUTHORIZED SIGNATURE: 4:61°�C"6D DATE: 1/812009 �eC ��5T� E .. RTIFICATE of £OI11lPUANCE AHSIIASR Z O090DI-20Q 00 P O R P % Registered ANSIIASQ Q9001-2000 r err Certlffed IWIKA11 CERTIFICATE OF COMPLIANCE Pressure and Temperature ACCURACY STATEMENT Measurement WIKA instrument Corporation 1 COD Wiegand Boulevard WIKA Instrument Corporation certifies that the products Lawrenceville, Georgia 30043 specified herein have been manufactured to the ASME Tel. 770-513-8200 840.100 accuracy grade listed. Fax 770-338-5118www.wika.cam in€o@aika.com CUSTOMER: ALLIED RUBBER & GASKET CO. 5400 SOUTH 66 STREET FORT SMITH, AR 72903 CUSTOMER P.O. NO.: 26482 ORDER NO.: 865505 ORDER DATE: 9125108 CUSTOMER PIN: 6510161 WIKA PIN: 4276192 DESCRIPTION: 111.10SP 4 30OPSI 114 L WATER ARGCO GAUGE RANGE(S): 30OPSI QUANTITY: 3000 ACCURACY GRADE: +1- 31213% OF SPAN AUTHORIZED SIGNATURE:`�'�` DATE: 1/6/2009 /4�- CERTIFICAT ��1 of COMPLIANCE �y ANSVASQ Q500f-20000 p�' 0RP�� Registered ANSTIASQ Q9001-2000 BELLS PBA-AC & MBA-DC 5400776 - REV Z • 11/17 PAGE 1 OF 2 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com Description These vibrating type bells are designed for use as fire or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4” (101mm) square electrical box for indoor use or on a model BBK-1 or HC-BB weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1 or HC-BB, Stock No. 1500001. Notes 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C) 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Technical Specifications Dimensions 6” (150mm), 8” (200mm) and 10” (250mm) Enclosure Cover: Steel Finish: Red Powder Coat Base: non-corrosive composite material All parts have corrosion resistant finishes Model BBK-1 or HC-BB weatherproof backbox (optional) Voltages Available 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Environmental Limitations Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Service Use NFPA 13, 72, local AHJ *Specifications subject to change without notice. Features • Listed for indoor and outdoor use • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4” box • Low current draw • High dB output • AC and DC models • DC models are motor driven, polarized, and have built in transient protection for supervised alarm circuits • Available in 6”, 8” and 10” sizes In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. R * ULC on MBA-DC Only Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150)12VDC MBA-6-12 1750070 .12A 85 76 8 (200)12VDC MBA-8-12 1750080 .12A 90 77 10 (250)12VDC MBA-10-12 1750060 .12A 92 78 6 (150)24VDC MBA-6-24 1750100 .06A 87 77 8 (200)24VDC MBA-8-24 1750110 .06A 91 79 10 (250)24VDC MBA-10-24 1750090 .06A 94 80 6 (150)24VAC PBA246 1806024*.17A 91 78 8 (200)24VAC PBA248 1808024*.17A 94 77 10 (250)24VAC PBA2410 1810024*.17A 94 78 6 (150)120VAC PBA1206 1806120*.05A 92 83 8 (200)120VAC PBA1208 1808120*.05A 99 84 10 (250)120VAC PBA12010 1810120*.05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. * 5400776 - REV Z • 11/17 PAGE 2 OF 2 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com BELLS PBA-AC & MBA-DC Wiring Rear View Installation Bell Dimension Inches (mm) Fig 1 Fig 3 2 11/16” (68 mm)DWG# 776-1 10” (250 mm)8” (200 mm)6” (150 mm) 5 3/4” (146 mm) 1 5/8” (41 mm) DWG# 776-2 3 3/8” (86 mm) 4 1/4” (108 mm) 3 3/8” (86 mm) 5” (127 mm) Weatherproof Backbox Dimensions Inches (mm) Fig 2 The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90” AFF and not less than 6” below the ceiling. 1. Remove the gong. 2. Connect wiring (see Fig. 3). 3. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). MODEL BBK-1 OR HC-BBFailure to install striker down will prevent bell from ringing. NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS.2. RED WIRES POSITIVE (+).3. BLACK WIRES NEGATIVE (-).4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. NOTES: 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY AFTER LAST BELL.2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS . NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS.2. RED WIRES POSITIVE (+).3. BLACK WIRES NEGATIVE (-).4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. NOTES: 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY AFTER LAST BELL.2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS .