Bundy #22-083ATTENTION: ALL ENGINEERING CALLOUTS ON THESE PLANS j MUST BE STRICTLY FOLLOWED! NO EXCEPTIONS! ANY CHANGES OR MODIFICATIONS MUST BE PRE - APPROVED BY THE ENGINEER OF RECORD! i Co�F� S .oP 2X4 OUTLOOKS @ -10 O.C. (2) 1 0d'5 PER SIMPSON A-35 CLIPS @ �IO.C. NOTE: ONLY FOR GABLE SHEATHING THAT DOES NOT OVERLAP AND EDGE NAIL WALL PLATES °D3 ROOF FRAMING DETAIL END TRUSS - WALL CONNECTION ROOF SHEATHING EDGE NAILING r- I x2 TRIM 21- FLY RAFTER EDGE NAILING /GABLE TRUSS SHEATHING / JOINT TO OVERLAP TOP PLATES 1-1/2" MINIMUM OVER -FRAMED RAFTERS: 10' SPAN or LESS = 2x6'5 @ 24" O.C. OVER I O' SPAN TO 12'-G" SPANS = (2) 2x6'5 @ 24" O.C. OVER 12'-G" SPAN TO 14-6" SPANS = (3) 2x6'5 @ 24" O.C. OPTION: #2 D.F. 2x 12'5 MAX. SPAN = 17-G" P+" ROOF FRAMING DETAIL OVER FRAMING RAFTERS - ROOF CONNECTION 2xG BLK. ON EDGE BTVVN. TRUSSES @ BRACE LOCATION 2x4 RUNNER w/ (2) 1 Od'5 PER TRUSS .\ I �I 5IMP50N GBC EA. SIDE OF 2xG DIAG. BRACE ROOF FRAMING DETAIL END WALL - TRUSS BRACE "Li-,, 1AILE K PLT. I Gd'5 PER .R 4" O.C. 8d'5 @ G" O.C. INTO 2x OUTLOOK � BLKG. 2xG DIAGONAL BRACE NEXT TO 2x4 RUNNER (2) 1 0d'5 TO RUNNER BRG / SHEAR WALL CONCRETE SLAB GXGX I OX 10 W.W.M.F. or FIBER MESH Carpentry: STRUCTURAL NOTES (FP] 0 d5 Ek 1. Structural 4X framing shall be #2 Doug -Fir. 51DE DF 5PLiCE 2. 6X columns/beams/headers shall be #1 Doug -Fir. CONTRACTOR, OWNER, AND FRAMER ARE TO 3. 2X 10d box rafters/joists shall be #2 Douglas -fir, kiln dried, w and stored in a dry area prior to installation. THOROUGHLY REVIEW THESE DOCUMENTS AND THEIR 4. Roof trusses shall be by a pre -approved manufacturer and RELATIONSHIP TO THE ARCHITECTURAL � _ •-��- constructed according to the specifications of the Truss PLANS. IF _ Plate Institute. Contractor and Truss Manufacturer are THERE ARE ANYQUESTIONS, OR DISCREPANCIES SOIL OR COMPACTED responsible for all bracing of the trusses including end N wall bracing and all other bracing between the building ABOUT THE NOTES, DETAILS, OR PLANS, CONTACT _ TOP and the trusses unless specifically shown otherwise on THE ENGINEER OF RECORD AT THOMPSON VIEW the drawings. g. Spectral response acceleration parameter Shc = null h. Seismic desi n cate or "D2" 5. Sheathing at roofs shall be 7/16" OSB, or ;-�" CDX laid ENGINEERING (509) 987-1599. �� 4" -� JI rP with face grain perpendicular to supports and end joints staggered 4'-0" on center. Provide 1/8" space between P These structural notes supplement the drawings. Any discrepancy edges as by \ panel required sheathing Manufacturer's. found among the drawings, these notes, and the site conditions Z = 380 plf. Roof sheathing shall be nailed with 8d box nails at 6" shall be reported to the Engineer, who shall correct such o.c. edges and 12 o.c. in the field U.O.N.on plans. discrepancy in writing. Any work done by the Contractor after CAUTION discovery of such discrepancy shall be done at the Contractor's i I �-- VENTED 2x13LKC-. I I i i i I I { ! i ! •. ADDITIONAL SHEAR WALL NOTES: foundation and to a double 2X6 stud with (16) 16d risk. The Contractor shall verify and coordinate the dimensions _ SIDE VIEW PLACE TRUSSES PER MANUFACTURER'S RECOMMENDATIONS. BRACE PER among all drawings prior to proceeding with any work or RECOMMENDATIONS. 6l fabrication. The Contractor is responsible for all bracing and /� 1JOTE:1� O MINIMUM b�IIti�EN SFL'CES shoring during construction. All construction shall conform to the CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING applicable portions of the latest edition the 2018 holdown posts. of International REQUIRED DURING PLACEMENT OF TRUSSES. Building Code except where noted. G DETAIL FL�?ME� PS ��C CONTRACTOR IS REQUIRED TO FIELD VERIFY ALL CONDITIONS AND ALL Construction Stability: TOP ELEVATIONS. CONCRETE SLAB GXGX I OX 10 W.W.M.F. or FIBER MESH FOUNDATION DETAIL TYPICAL CONCRETE SLAB W/ EDGE FTG. SIMPSON - ` H- I cups @ 0. C. TYPICAL SHEAR -WALL NOTES The design, adequacy and safety of erection bracing, shoring and all temporary supports is the sole responsibility of the Contractor, and has not been considered by the Engineer of All wall sheathing shall be 15/32" CDX plywood, 7/16" OSB (with Record. The Contractor shall provide the bracing necessary to studs at 16"o.c.), or as called out below, with exterior provide stability to the structure prior to the completed exposure glue and span rated "SR 24/0" or better. (5/8" T1-11 application of the lateral resisting system. During siding is an acceptable substitution except where 5/8" or construction, the Contractor shall keep loads within the thicker sheathing is specifically called out in the schedule design roof and floor load limits indicated below. below). Sheathing may be installed either horizontally or vertically. Design Criteria: 7. SILL PLATE All nails shall be per table below. Nail size and spacing at 1. Live Load = 25 PSF (Snow) W/A.B.5 PER PLAN all sheathing edges shall be as required in shear -wall schedule 2• Dead Load _ 15 PSF (Roofs) / W/ 3ax3x1/4" PLATE WASHER below. 10 PSF (Wood walls) 150 PCF (Concrete) TYPI�AL (SEE PLAN) f Ilr Nail Type Diameter (inches) Length (inches) �� I I-1 I �I I�� 11=1 I �I I � I • ° ` II�II�I�II�II�I�II 10d box 0.128 3 IIS I�II�II�II�I� 0.148 HI 01 IIrIIrII�I 1laIFIILIIE NATIVE UNDISTURBED- =III=1I 11=1I�uI=I SOIL OR COMPACTED 0.148 STRUCTURAL FILL �I FOUNDATION DETAIL TYPICAL CONCRETE SLAB W/ EDGE FTG. SIMPSON - ` H- I cups @ 0. C. TYPICAL SHEAR -WALL NOTES The design, adequacy and safety of erection bracing, shoring and all temporary supports is the sole responsibility of the Contractor, and has not been considered by the Engineer of All wall sheathing shall be 15/32" CDX plywood, 7/16" OSB (with Record. The Contractor shall provide the bracing necessary to studs at 16"o.c.), or as called out below, with exterior provide stability to the structure prior to the completed exposure glue and span rated "SR 24/0" or better. (5/8" T1-11 application of the lateral resisting system. During siding is an acceptable substitution except where 5/8" or construction, the Contractor shall keep loads within the thicker sheathing is specifically called out in the schedule design roof and floor load limits indicated below. below). Sheathing may be installed either horizontally or vertically. Design Criteria: 7. SILL PLATE All nails shall be per table below. Nail size and spacing at 1. Live Load = 25 PSF (Snow) W/A.B.5 PER PLAN all sheathing edges shall be as required in shear -wall schedule 2• Dead Load _ 15 PSF (Roofs) / W/ 3ax3x1/4" PLATE WASHER below. 10 PSF (Wood walls) 150 PCF (Concrete) TYPI�AL (SEE PLAN) f Ilr Nail Type Diameter (inches) Length (inches) 8d box 0.113 2-1/2 10d box 0.128 3 16d sinker 0.148 3-1/4 8d common 0.131 2-1/2 10d common 0.148 3 3. Wind : 2018 IBC a. Basic wind speed = 110 mph b. V-asd wind speed = 85 mph C. Risk category = "II" d. Exposure category = "B" e. Internal pressure coefficient = +0.55/-0.55 4 Earth wake 2018 IBC Ir .121 S �I� a. Risk category = II 1111=b. ALL EARWALL FRAMING LUMBER SHALL BE #2 DOUG -FIR SPECIES Importance factor "I" = 1.0 Spectral =11�C per the manufacture's recommendation. 4. c. response acceleration parameter Ss = 1.314 MATER d. Spectral response acceleration parameter S1 = 0.526 plate washers. EDGE NAILING SHEAR -WALL SCHEDULE e. Site classification = "D" f. Spectral response acceleration parameter Sds = 1.051 (3�#4 BAR CONTINUOUS hthinailed with 8d box at 6" on center all edges \Wseang = 260 g. Spectral response acceleration parameter Shc = null h. Seismic desi n cate or "D2" W/,24'LAP TYPICAL plf. i. Seismic response coefficient CS = 0.127 sheathing nailed with 8d box at 4" on center all edges j. Response modification factor = 6.5 Z = 380 plf. k. Basic force resisting system = bearing walls -"K" All concrete work shall be per the 2018 IBC Chapter 19. �-- VENTED 2x13LKC-. 1. Design procedure = Simplified analysis LSTHD8/LSTHD8RJ--embeds a minimum of 8 inches into concrete 5. Soil = 1500 PSF, Assumed Bearing Capacity ADDITIONAL SHEAR WALL NOTES: foundation and to a double 2X6 stud with (16) 16d * Blocking is required at all horizontal edges Of Foundation sheathing. Sheathing edge nailing is required at all 03, 04, 05, and 06. holdown posts. 1. All footings shall be founded on native undisturbed soil. - * Intermediate framing is to be minimum 2x members with 2. Optional: A continuous 4" diameter perforated footing Cement: ASTM C150, normal -Type I or I-II. Coarse or fine aggregate: ASTM C33. All reinforcing be ASTM A615 Grade 40 for nailing at 12" on center. drain shall be placed around the entire perimeter of the 10" minimum into concrete. LTT20B attaches to double 2X * Double 2x studs nailed together with (2) rows of 10d's foundation and installed as shown on the drawings. The at 4" o.c. may be used in place of a single 3x stud, footing drain shall be sloped and terminated at an TRUSSES @ 24" O.C. unless other wise required in holdown schedule below. approved location down hill of the structure. 3. Pressure -treated Mud -sills: Use 1/2" diameter X 10" ASTM HOLDOWN SCHEDULE A307 anchor bolts at 60" on center with pressure treated 2x nominal thickness plates, unless otherwise noted on i- ROOF SHEATHING x ld-d h 11 b Sim son "St 'r d h 11 b t 11 d the f d t' 1 D ROOF FRAMING DETAIL TRUSS - WALL CONNECTION THOMPSON ENGINEERING, INC. 541 JORDAN LN RICHLAND, WA 99352 PHONE: (509) 987-1599 email: rthompsonengineering@yaho SCALE: PROJECT #22003 DRAWN BY: DATE: REVISED: BUNDY COFFEE STAND STRUCTURAL NOTES & DETAILS DRAWING'NUMBER: SHEET SI OF 1 \1�1 T H OM 24:) QA � 2 0 owns s a e p Hong ie an s a e ins a e oun a ion p an. per the manufacture's recommendation. 4. All anchor bolts shall use 3" square x 1/4" thick steel plate washers. EDGE NAILING All double OR triple studs (ALLOWED PER HOLDOWN SCHEDULE BELOW) shall be nailed together with (2) rows 10d's staggered at 4" on Concrete & Reinforcing Steel: center each row for each layer. 1. All concrete work shall be per the 2018 IBC Chapter 19. �-- VENTED 2x13LKC-. LSTHD8/LSTHD8RJ--embeds a minimum of 8 inches into concrete Tolerances shall be per IBC Chapter 19, Section 07. foundation and to a double 2X6 stud with (16) 16d Mixing, placement, and inspection shall be per Sections sinker nails in wall above. 03, 04, 05, and 06. LTT20B attaches to concrete foundation with a 5/8" diameter bolt 2. 3. 4. Cement: ASTM C150, normal -Type I or I-II. Coarse or fine aggregate: ASTM C33. All reinforcing be ASTM A615 Grade 40 for 10" minimum into concrete. LTT20B attaches to double 2X shall #4 bars or smaller and Grade 60 for #5 bars or larger. studs with (10) 16d SINKER nails in wall above. 5. Use 24" elbow bars at all footing and stemwall corners -- and intersections at horizontal continuous reinforcement. BRG/SHEAR WALL ATTENTION 6. Admixtures: Water reducers -ASTM C494, Type A. Air or5EAM - SEE PLAN • entrainment -ASTM C260 and ASTM C494, with no chlorides. ALL ENGINEERING CALLOUTS ON THESE PLANS 7 Concrete shall be in accordance with ASTM 150. Do not use calcium chloride, fly ash or related materials. MUST BE STRICTLY FOLLOWED! NO EXCEPTIONS! f'c = 2500 PSI @ 28 day -5-1/2 sack mix -3/4" maximum size aggregate. Slump = 5" 6% Air maximum, max entrained. ANY CHANGES OR MODIFICATIONS MUST BE PRE - APPROVED BY THE ENGINEER OF RECORD! THOMPSON ENGINEERING, INC. 541 JORDAN LN RICHLAND, WA 99352 PHONE: (509) 987-1599 email: rthompsonengineering@yaho SCALE: PROJECT #22003 DRAWN BY: DATE: REVISED: BUNDY COFFEE STAND STRUCTURAL NOTES & DETAILS DRAWING'NUMBER: SHEET SI OF 1 \1�1 T H OM 24:) QA � 2