Long Shot Gun Range - Elevation PlansBUILDING INFORMATION BUILDING DESCRIPTION: NEW INDOOR SHOOTING RANGE SHOOTING RANGE BUILDING, INCLUDING A 100 METER AND 25 METER RANGE, PRO- SHOP, STORAGE/LOCKER, GUN MAINTENANCE, AND TRAINING FACILITIES. MODEL CODE: 2018 IBC CONSTRUCTION TYPE: VA NUMBER OF STORIES: 2 BUILDING HEIGHT: 28' (TO TOP OF PARAPET) OCCUPANCY TYPE: M, B, S-1, A-3 (MIXED USE) BUILDING AREA: 36,860 SF SITE AREA: 387,684 SF (8.9 ACRES) SITE ADDRESS: 16910 STATE ROUTE 507 SE, YELM, 98597 PARCEL #'s: SOUTH PARCEL: 64303100800 NORTH PARCEL: 64303100801 ABBREVIATED LEGAL DESCRIPTIONS: MC KENNA IRR TR L8 BLK 31 THAT PTN DAF BEG AT X ELN SSH #5- H N419. 5F W233F MC KENNA IRR TR L8 BLK 31 LESS PTN DAF BEG AT X ELN L8 & NL N SSH K JURISDICTION: CITY OF YELM MASTER FILE # __________________________________________ LAND USE APPROVAL ON ________________________________ **SEE SITE PLAN FOR ADDITIONAL INFORMATION DEFERRED SUBMITTALS (REQUIRED FOR BUILDING PERMIT) 1. SUBMITTAL 1 2. SUBMITTAL 2 BUILDING ENVELOPE THE PROJECT OWNER/DEVELOPER WILL ENGAGE THE SERVICES OF A THIRD PARTY INSPECTOR TO INSPECT THE EXTERIOR ENVELOPE DURING THE COURSE OF CONSTRUCTION FOR COMPLIANCE WITH THE BUILDING ENCLOSURE DESIGN AND FILE INSPECTION REPORT TO JURISDICTION. IF REQUIRED, PRIOR TO FINAL OCCUPANCY, SUBMIT A FOLLOW-UP REPORT TO JURISDICTION NOTING CORRECTIVE MEASURES TAKEN. THE COMPLETED BUILDING SHALL BE TESTED, AND THE AIR LEAKAGE RATE OF THE BUILDING ENVELOPE SHALL NOT EXCEED 0.25 CFM/FT2 AT A PRESSURE DIFFERENTIAL OF 0.3 INCHES WATER GAUGE (2.0 L/S X M2 AT 75 PA) AT THE UPPER 95 PERCENT CONFIDENCE I NTERVAL IN ACCORDANCE WITH ASTM E 779 OR AN EQUIVALENT METHOD APPROVED BY THE CODE OFFICIAL. A REPORT THAT INCLUDES THE TESTED SURFACE AREA, FLOOR AREA, AIR BY VOLUME, STORIES ABOVE GRADE, AND LEAKAGE RATES SHALL BE SUBMITTED TO THE BUILDING OWNER AND THE CODE OFFICIAL. IF THE TESTED RATE EXCEEDS THAT DEFINED HERE BY UP TO 0.15 CFM/FT2, A VISUAL I NSPECTION OF THE AIR BARRIER SHALL BE CONDUCTED, AND ANY LEAKS NOTED SHALL BE SEALED TO THE EXTENT PRACTICABLE. AN ADDITIONAL REPORT IDENTIFYING THE CORRECTIVE ACTIONS TAKEN TO SEAL AIR LEAKS SHALL BE SUBMITTED TO THE BUILDING OWNER AND THE CODE OFFICI AL AND ANY FURTHER REQUIREMENT TO MEET THE LEAKAGE AIR RATE WILL BE WAIVED. IF THE TESTED RATE EXCEEDS 0.40 CFM/FT2, CORRECTIVE ACTIONS MUST BE MADE, AND THE TEST COMPLETED AGAIN. A TEST ABOVE 0.40 CFM/FT2 WILL NOT BE ACCEPTED. **SEE SITE PLAN FOR ADDITIONAL INFORMATION. SEE CODE REVIEW SHEET A-003 FOR MORE INFORMATION. DESIGN TEAM OWNER: LONG SHOT INC. 16910 STATE ROUTE 507 YELM, WA 98597 CONTACT: JASON PEARSON PHONE: 360-400-4010 EMAIL: EVP@LONGSHOTIR.COM ARCHITECT: THOMAS ARCHITECTURE STUDIOS 525 COLUMBIA ST SW OLYMPIA, WA 98501 PHONE: 360-915-8775 CONTACT: DONNIE HULL EMAIL: DONNIE@TASOLYMPIA.COM CIVIL ENGINEER/LANDSCAPE ARCHITECT: PACLAND 6814 GREENWOOD AVE N SEATTLE, WA 98103 PHONE: 206-522-9510 CONTACT: BILL FORTUNATO EMAIL: BFORTUNATO@PACLAND.COM STRUCTURAL ENGINEER: PCS STRUCTURAL SOLUTIONS 1250 PACIFIC AVE, SUITE 701 TACOMA, WA 98402 CONTACT: JEFF KLEIN PHONE: 253-383-2729 EMAIL: JKLEIN@PCS-STRUCTURAL.COM MECHANICAL ENGINEER: HULTZ BHU 1111 FAWCETT AVE, SUITE 100 TACOMA, WA 98402 CONTACT: RICK HULTZ PHONE: 253-383-3257 EMAIL: RICKH@HULTZBHU.COM ELECTRICAL ENGINEER: CROSS ENGINEERS 923 MARTIN LUTHER KING JR WAY TACOMA, WA 98405 PHONE: 253-759-0118 CONTACT: SCOTT KELLY EMAIL: SCOTTK@CROSSENGINEERS.COM RANGE DESIGNER: INVERIS TRAINING SOLUTIONS 296 BROGDON RD SUWANEE, GA 30024 PHONE: 612-710-3031 CONTACT: ELTON STEELE EMAIL: ELTON.STEELE@INVERISTRAINING.COM PROJECT LOCATION510 507NIS Q U ALLY RIVER Y E L M MECHANICAL M1.01 FIRST FLOOR PLAN M1.02 SECOND FLOOR PLAN M1.03 THIRD FLOOR PLAN M1.04 FOURTH FLOOR PLAN ELECTRICAL M1.01 FIRST FLOOR PLAN M1.02 SECOND FLOOR PLAN M1.03 THIRD FLOOR PLAN M1.04 FOURTH FLOOR PLAN STRUCTURAL M1.01 FIRST FLOOR PLAN M1.02 SECOND FLOOR PLAN M1.03 THIRD FLOOR PLAN M1.04 FOURTH FLOOR PLAN 525 COLUMBIA ST. | OLYMPIA, WA 98501 360.915.8775 | tasolympia.com All material herein constitutes the original and unpublished work of the architect and may not be used, duplicated, or disclosed without the written consent of the architect. Copyright © 2022 by Thomas Architecture Studio. All rights reserved. A-001 Project No: 2212 JULY 25, 2022 DESIGN DEVELOPMENTLONG SHOT INDOOR RANGELONG SHOT INC.16910 WA-507 SE | YELM, WACOVER SHEET LONG SHOT INC. LONG SHOT INDOOR RANGE SITE VICINITY SHEET LIST ARCHITECTURAL A-001 COVER SHEET A-002 ABBREVIATIONS & SYMBOLS A-003 CODE REVIEW A-004 EGRESS PLANS A-101 SITE PLAN A-102 SITE FEATURES A-200 FOUNDATION PLAN A-201 PLAN - FLOOR 1 A-202 ENLARGED PLAN - FLOOR 1 A-203 ENLARGED PLAN - FLOOR 2 A-204 REFLECTED CEILING PLAN - FLOOR 1 A-205 REFLECTED CEILING PLAN - FLOOR 2 A-206 ROOF PLAN A-301 ELEVATIONS A-401 BUILDING SECTIONS A-501 WALL SECTIONS A-502 WALL SECTIONS A-503 WALL SECTIONS A-504 WALL SECTIONS A-505 ENTRY CANOPY A-506 STAIRS A-601 ASSEMBLIES A-602 ENVELOPE DETAILS A-603 GENERAL DETAILS A-701 INTERIOR ELEVATIONS A-702 INTERIOR ELEVATIONS A-801 SCHEDULES A-802 SPECIFICATIONS A-803 SPECIFICATIONS A-901 PERSPECTIVES