2022.02.10 NHD 2565 Structural AnalysisLateral and Gravity Analysis
for
NHD 2565 BH Plan
15426 Prairie Wind Ct SE
Yelm, WA 98597
for
C&E Development
P.O. Box 2983
Yelm,WA 98597
by
N.L. Olson & Associates, Inc.
2453 Bethel Avenue
Port Orchard, WA 98366
360-876-2284
NLO #10006-17
February-22
Scope of Work:
Engineering for two story SFR based on NHD 2565 BH plan.
Analysis was done using the 2018 International Building Code
Materials:
Framing: HF #2 or better
Beams: DF #2 or better
Glulam: Douglas Fir 24F -V4 for simple supported and 24F -V8 for continuous or cantilevered beams
Reinforcing Steel: ASTM A615 Grade 60
Concrete: fc = 2500 psi
Design Assumptions:
Soil Properties: 1500 psf Beanng Capacity, 250 psf/ft lateral capacity (assumed)
Design Wind: 110 MPH 3 sec gust
Seismic Zone D
S. = 160%
Sr = 60.0%
Snow Load: 45 psf Ground
CONTENTS:
Page
1
Gravity and Lateral Loads
Page
2
Building Layout and Wind Load Analysis
Page
3
Seismic Load Analysis
Page
4-16
Shear wall and Diaphragm Analysis
Page
17-20
Beam and Joist Analysis
Page
21-27
Critical Footing Pad Analysis
Page
28-31
Appendix
Dead Loads
Live Loads
Snow Loads
Wind Loads
Seismic Loads
Foundation Footin
Floor= 12 psf(3 Joists,3 sub600r, 4coverings)
Wall = 10 psf(1.5 studs,2.5 sheathing,0.5 insul. 3 paneling)
Roof = 15 psf (2 psf truss, 1 insulation, 3 ceiling, 5, roofing)
Floor, L,= 40 psf
Roof, L, = 25 psf
Exposure Category C
Risk Category II
Ct =
Ce =
Is=
Cs=
Pg =
Pf = 0.7Ce'CCis'Pg
Pf = 34.65 psf (ASCE 7-16 7.3-1)
Ps = Cs'Pf
Ps = 34.65 psf (ASCE 7-16 7.4-1)
Use 45 psf for design
Vult = 110 mph (3 Sec. Gust)
Exposure R
Site Class D (Assumed)
Ss = 1.6 (USGS)
S1= 0.6 (USGS)
Roof Dead Load=
(ASCE 7-16 26.7.3)
Roof Live Load=
(ASCE 7-16 1.5-1)
1.1
(ASCE 7-16 Table 7-3)
1
(ASCE 7-16 Table 7-2)
1
(ASCE 7-16 Table 1.5-2)
1
(ASCE 7-16 Figure 7-2)
45 psf
(ASCE 7-16 Figure 7-1)
Pf = 34.65 psf (ASCE 7-16 7.3-1)
Ps = Cs'Pf
Ps = 34.65 psf (ASCE 7-16 7.4-1)
Use 45 psf for design
Vult = 110 mph (3 Sec. Gust)
Exposure R
Site Class D (Assumed)
Ss = 1.6 (USGS)
S1= 0.6 (USGS)
Roof Dead Load=
270 Ib/ft
Roof Live Load=
810 IWft
Floor Dead Load=
108 IWft
Floor Live Load=
360 IWft
Footing Width =
1.032 ft
Use 16"
footing width
Building Layout 34 ft
Assumed North
42ftI
Wind Loads (Simulfied Envelope Methodl (Per ASCE 7-16 Section 28.2-11
Ehr= 9.5
F1 ft
h1=8
-Ei ft
h2= 9
F ft
b = 42.00 ft
Case A - East-West Wind
hr= 9.5
Fl
b = 34.00
1 ft
Case B - North-South Wind
Roof Angle
1 ht = 6
degrees
V=
110 mph
ft
JF2:
4.2 ft
A=
11 h2= 9
ft
b = 34.00
ft
Case B - North-South Wind
Roof Angle
6:12 or 26.56
degrees
V=
110 mph
(ASCE 7-16 Figure 26.5-1)
a=
4.2 ft
A=
1
A =
24.1 psf (ASCE 7-16 Figure 28.6-1)
B =
8 psf
C =
17.4 psf
D =
8 psf
Case A
F1=
5423 lbs
F2 =
7363 lbs
Case B
F1=
6641 lbs
F2=
6830 lbs
Seismic Loads
Site Class 0
29020 lbs
Risk Category II
Weight @ Floor =
Ss= 1.6
Fa = 1.2
(ASCE 7-16 Table 11.4-1)
Sms = Fa'Ss = 1.92
V = CsW = 12457
Sds = (2/3)'Sms = 1.280
• Design Category D (ASCE 7-16 Table 11.6-1)
S1=0.6
Fv = 1.7
(ASCE 7-16 Table 11.4-2)
Sm1 = S1 •Fv = 1.02
SO=(2/3)'Smt = 0.5
*Design Category D (ASCE 7-16 Table 11.6-2)
R = 6.5
(ASCE 7-16 Table 12.2-1)
0=3
(ASCE 7-16 Table 12.2-1)
Cd = 4
(ASCE 7-16 Table 12.2-1)
Is= 1
(ASCE 7-16 Table 1.5-2)
Approximate period per ASCE 7-16 Section 12.8.2.1
Ct= 0.02
x = 0.75
TIL =6
T = 0.2169
seconds
Cs = (Sdsy(R/le) = 0.1969
Csmax = 0.3547
Csmin = 0.0563
Use Cs = 0.197
Weight of the Structure
Weight @ Roof =
29020 lbs
Weight @ Floor =
34236lbs
Wtotal =
63256 lbs
V = CsW = 12457
Itis
Total applied earthquake load
K = 1
(ASCE 7-16 12.8.3)
Cv1 = 0.616
Cv2 = 0.384
F1 = 9201
lbs
(Includes 1/2 upper walls and roof)
F2 = 5747
lbs
(Includes 1/2 walls and floor)
North Wall Wooer Floor) (Perforated Method) (Seismic
H =
8 It
(Wall height)
W =
34 ft
(Wall width)
Wf=
2166 ft
(Wall width wl full height sheathing)
F=
4601 be
(Horizontal bad)
w =
56 Wit
(Vertical load)
ft = 208.27 psi Ft' = 1260 psi Works
W
(Attatchment)
Check Shear
p = 1.3
v = 438 Ib/ft vs = 560 Ib/ft (SDPWS Table 4.3A)
0.8
Use 7/16in sheathing w/ 8d nails@ 4in edge spacing
Check Studs
Cc = 63.0%
T=C=1718.23 lb Try2"x6" A=8.25 in -2
k = 208.27 psi Fc' = 2080 psi Works
ft = 208.27 psi Ft' = 1260 psi Works
Use No.2 HF 2x8 @ wall ends
Check Holddowns
Flo = 130 Itis Net Uplift
Use MSTC28
Check Deflections
Ga = 15 Cd = 4 (ASCE 7-16 12.8.6)
Wall Deflection = 1.19 in Allowable Deflection =.02H = 1.92
in
Meets deflection crHeria
South Wall !Upper Floor) (Perforated Method) (Seismic
H =
8 ft
(Wall height)
W =
34 ft
(Wall width)
Wf=
18.25 ft
(Wall width w/ full height sheathing)
F=
4601 Itis
(Horizontal load)
w=
661b/ft
(Vertical load)
W
(Attatchment)
Check Shear
p = 1.3
v = 655 Ib/ft vs = 720 Ib/ft (SDPWS Table
4.3A)
0.8
Use 7116in sheathing w/ Sd nails@ Sin edge spacing
Check Studs
Co = 50.0%
T=C=2164.98 lb Try 2SB" A=8.25
in -2
fc = 262.42 psi FC = 2080 psi
Works
ft = 262.42 psi Ft = 1260 psi
Works
Use No.2 HF 2x6 @ wall ends
Check Holddowns
Fto = 130 lbs Net Uplift
No Holdown Required
Check Deflections Ga = 22 Cd = 4 (ASCE 7-16 12.8.6)
Wall Deflection = 1.22 in Allowable Deflection =.02H = 1.92
in
Meets deflection criteria
East Wall (Upper Floor) (Perforated Method)(Seismic
H =
8 ft
(Wall height)
W =
38 ft
(Wall width)
Wf=
28 ft
(Wall widthw/full height sheathing)
F=
4601 lbs
(Horizontal load)
w=
56 lb/ft
(Vertical load)
T=C=1614.24 lb Try 2"x6" A=8.25
W
(Attatchment)
Check Shear
/, = 1.3
v= 356 Ib/ft vs = 384 Ib/ft (SDPWS Table 4.3A)
0.8
Use 7M6in sheathing wl 8d nails@ Sin edge spacing
Check Studs
Co = 60.0%
T=C=1614.24 lb Try 2"x6" A=8.25
in -2
h = 195.66 psi Fc' = 2080 psi
Works
ft = 195.66 psi Ft' = 1260 psi
Works
Use No.2 HF 2x6 @ wall ends
Check Helddowns
Fto = -95 lbs No Net Uplift
No Holdown Required
Check Deflections Ga = 15 Cd = 4 (ASCE 746 12.8.6)
Wall Deflection = 0.98 in Allowable Deflection =.02H = 1.92
in
Meets deflection criteria
West Wall (Upper Floorl (Perforated Method) (Seismic
H =
8 ft
(Wall height)
W =
38 ft
(Wall width)
Wf=
34 ft
(Wall width w/ full height sheathing)
F=
46011bs
(Horizontal load)
w=
561b/ft
(Vertical load)
ft = 146.75 psi Ft' = 1260 psi Works
W
(Attatchment)
Check Shear
p = 1.3
v= 220 Ib/ft vs = 384 Ib/ft (SDPWS Table 4.3A)
0.8
Use 7/16in sheathing w/ 8d nails@ Sin edge spacing
Check Studs
Co = 80.0%
T=C=1210.68 lb Try 2"x6' A=8.25 in A2
fc = 146.75 psi Fc' = 2080 psi Works
ft = 146.75 psi Ft' = 1260 psi Works
Use No.2 HF 2xfi @ wall ends
Check Holddowns
Fto = -95 lbs No Net Uplift
No Holdown Required
Check Deflections
Ga = 15 Cd = 4 (ASCE 7-16 12.8.6)
Wall Deflection = 0.69 in Allowable Deflection =.02H = 1.92
in
Meets deflection criteria
North Wall (Main Floor) (Segmented Method) (Seismic
H =
9 ft
(Wall height)
W =
6.75 ft
(Wall width)
Wf=
6,75 ft
(Wall width w/ full height sheathing)
F=
6037.3 Itis
(Horizontal load)
w=
194.6 lb/ft
(Vertical load)
ft = 975.72 psi Ft = 1260 psi Works
F
(Attatchment)
Check Shear
p = 1.3
v = 1163 Ib/ft vs = 1344 Ib/ft (SDPWS Table 4.3A)
0.8
Use 15/32in sheathing w/ 10d nai Sin edge spacing
Check Studs
Cc= 100.0%
T=C=8049.67 It, Try 2"x6' A=8.25 W2
fc = 975.72 psi Fc' = 2080 psi Works
ft = 975.72 psi Ft = 1260 psi Works
Use No.2 HF 2x6 @ wall ends
Check Anchors
z = 1922.4 Ibbolt (NOS Table 11 E, is=1 12in, 5/8", HF)
S= 1.65 ft
Use 5181 anchor bolts @ 30in
Check Holddowns
Flo = 28510 lbs Net Uplift
Use HDU14
Check Deflections
Ga = 36 Cd = 4 (ASCE 7-16 12.8.6)
Wall Deflection = 2.15 in Allowable Deflection =.02H = 2.16
in
Meets deflection criteria
East Wall (Main Floor) (Perforated Methodl (Seismic
H =
9 ft
(Wall height)
W =
36 It
(Wall width)
Wf=
23.5 it
(Wall width w/full height sheathing)
F=
7473.9 lbs
(Horizontal load)
w=
153 Will
(Vertical load)
ft = 348.44 psi FY = 1260 psi Works
F
(Attatchment)
Check Shear
/, = 1.3
v= 636 Ib/ft vs = 720 Wit (SDPWS Table 4.3A)
0.8
Use 7116in sheathing w/ Bd nails@ Sin edge spacing
Check Studs
Co = 65.0%
T = C = 2874.59 Ib Try 2"x6" A= 8.25 in -2
fc = 348.44 psi Fc = 2080 psi Works
ft = 348.44 psi FY = 1260 psi Works
Use Not HF 2x8 @ wall ends
Check Anchors
z = 1922.4 Ib/boh (NDS Table 11E, is=1 12in, 518", HF)
S = 3.02 ft
Use 5/8in anchor bolts @ 30in
Check Holddowns
Fto = -886 lbs No Net Uplift
No Holdown Required
Check Deflections
Ga = 22 Cd = 4 (ASCE 7-16 12.8.6)
Wall Deflection = 1.33 in Allowable Deflection =.02H = 2.16
in
Meets deflection criteria
West Wall (Main Floor) (Segmented Method) (Seismic
H =
9 ft
(Wall height)
W =
22 it
(Wall width)
Wf=
22 It
(Wall width w/ full height sheathing)
F=
7474 lbs
(Horizontal bad)
w=
153 lb/ft
(Vertical load)
F
(Attatchment)
Check Shear p = 1.3
v = 442 Ib/ft vs = 560 Ib/ft (SDPWS Table 4.3A)
0.8
Use 7116in sheathing w/ fid nails@ Alin edge spacing
Crack Studs Cc= 100.0%
T=C=3057.52 lb Try 7'x6" A=8.25 in -2
k = 370.61 psi Fc' = 2080 psi Works
ft = 370.61 psi Ft' = 1260 psi Works
Use No.2 HF 2x6 @ wall ends
Check Holddowns Flo = 1375 Itis Net Uplift
No Holdowm Requried
Check Deflections Ga = 15 Cd = 4 (ASCE 7-16 12.8.6)
Wall Deflection = 1.51 in Allowable Deflection =.02H = 2.16
in
Meeh deflection criteria
South Wall (Main Floor) (Segmented Methodl (Wind
H =
9 ft
(Wall height)
W =
5 it
(Wall width)
Wf=
5 f
(Wall width w/ full height sheathing)
F=
2841 Itis
(Horizontal load)
w=
153 Wit
(Vertical load)
ft= 619.90 psi Ft' = 1260 psi Works
F
(Attatchment)
Check Shear
p = 1
Actual Width of Portal = 24
v = 568 Ib/ft vs = 720 Ib/ft (SDPWS Table 4.3A)
Interpolated Allowable Shear = 1960
0.8
#segments= 2
Use 7/16in sheathing wl 8d nails@ Sin edge spacing
Check Studs
Cc = 100.0%
V = 6613
T = C = 5114.16 1b Try 2"x6" A= 8.25 in -2
fc = 619.90 psi Fc' = 2080 psi Works
ft= 619.90 psi Ft' = 1260 psi Works
Use Not HF 2x6 @ well ends
Check Anchors
z=1922.4 lb/bolt (NDS Table 11 E, ts=11/2in, 5/8", HF)
S = 3.38 It
Use 5181n anchor bolts @ 30in
Check Holddowns
Flo= 1498 lbs Net Uplift
Use STHD14RJ
Check Deflections
Ga = 36 Cd = 4 (ASCE 7-1612.8.6)
Wall Deflection = 2.29 in Alkwrable Deflection =.02H = 2.16
in
Use Portal Frame for south wall per APA report TT -100
Wall Height= 9
It
Actual Width of Portal = 24
inches
Interpolated Allowable Shear = 1960
Ibs
#segments= 2
Total Resistance = 3920
Itis
V = 6613
lbs (from Seismic cal s)
Interior Wall (Main Floor) (Segmented Method) (Seismic
H =
9 ft
(Wall height)
W =
19 it
(Wall width)
Wf=
19 ft
(Wall width w/ full height sheathing)
F =
1437 lbs
(Horizontal bad)
w=
153 lb/ft
(Vertical load)
ft = 82.49 psi Ff = 1260 psi Works
F
(Attatchment)
Check Shear
p = 1.3
V= 98 Wit vs = 384 Ib/ft (SDPWS Table 4.3A)
0.8
Use 7/16in sheathing w/ 8d nails@ Gin edge spacing
Check Studs
Co= 100.0%
T=C=680.53 Ib Try 2-4" A=8.25 inA2
fc = 82.49 psi Fc' = 2080 psi Works
ft = 82.49 psi Ff = 1260 psi Works
Use No.2 HF 2x6 @ wall ends
Check Anchors
z = 1922.4 Ib/boft (NDS Table 11E, is=1 12in, 5/8", HF)
S= 19.56 ft
Use 518in anchor bolts @ 48in
Check Holddowns
Fto = 655 lbs Net Uplift
11,71.1 rlln
Check Deflections Ga = 15 Cd = 4 (ASCE 7-16 12.8.6)
Wall Deflection = 0.63 in Aflomble Deflection =.02H = 2.16
in
Meets deflection criteria
Roof Diaphragm (Case 11
Fr=
11961 Itis
(From Seismic Analysis)
Firmin =0.2•le'Sds'W =
7429 lbs
(ASCE 7-16 Equation 12.10-2)
Frmax=0.4'fe'Sds'W =
14858 lbs
(ASCE 7-16 Equation 12.10-3)
E -W Shear Force = 11961 lbs
E -W Shear Load = 315 Ib/ft
Mmax = 56817 lb -ft
Tension in Chord = 1671 Itis
176 Ib/ft
ICMI
(Case 1)
V 176 Wit
V= 0 Ib/ft
vs = 272 Ib/ft (SPDWS Table 4 2B)
08
Use 7/16" Sheathing w/ 8d nails @ 6in (Unblocked)
Roof Diaohraam (Case 3)
Fr= 11961 lbs (From Seismic Analysis)
Firmin =0.2`le'Sds'W = 7429 lbs (ASCE 7-16 Equation 12.10-2)
Fnnax=0.4`le'Sds'W = 14858 lbs (ASCE 7-16 Equation 12.10-3)
34 ft
E -W Shear Force =
E -W Shear Load =
Mmax =
Tension in Chord =
157 Wit
v = 157 Wit
vs=272 Wit
11961 lbs
352 Ib/ft
50836 Ib -ft
1338 lbs
157 Ib/ft
0.8
Use 7116" Sheathing w/ 6d nails @ Bin (Unblocked)
38 ft}
N
(Case 1)
(SPDWS Table 4.21B)
NL Olson S Associates, Inc.
Project Tide:
2453 Bethel Ave.
Engineer
PO Box 637
Project ID:
Pon Orchanl, WA 98366
Project Descr:
(360) 8762284
Wood Gade'. 24F -V4
Muldpk Simple Beam
-
LILY 1007-05015858. BUI4202226
OLSON&AS60CATE5 M ENERCALC INC 198}2022
Description
Wood Beam Design: Garage Door Header
Calculations; per NDS 2818, IBC 2818, CBC 2019, ASCE 746
BEAM Size:
3.5x12, GLB, Fully Braced
Lisirg Load Resistance Factior Design w4h IBC 2018 Load Combinations, Major Nus Bending
Un# Load: D = 0.0150, Lr= 0.030, 5 = 0.0450 lint, Tnb= 12.0 It
Wood Species:
DF/DF
Wood Gade'. 24F -V4
Design Summary
Fb- Tension
2.400.0 psi Fc - PHI 1,650.0 psi Fv
265.0 psi Ebmd-xx 1,800.0ksi Density
32.210 pct
Fb-Compr
1,850.0 psi Fc -Pery 650.0 psi Ft
1,100.0 psi Eminttend-xx 930.0 bi
ApMed Loads
fb Actual-
Unp Load: D=0.0150,
1r=0,030. 5= 0.0450 k/fl, 0.0 It to 100 ft, Trib=2.OIt
UnR Load: D=0.0150,
Lr=0.030, 5= 0.0450 M, 10.0 m 16.0 ft, Tdb= 3.0 It
Fb : Allowable:
Design Summary
-
Max Ratio
= 1
D(O g3gf LgpO6g) S(g.g90 0(0.0750) Lng.08n) S(0.1350)
- ---
Achna
In. Adral :
psi at 8.58] fl in Sloan # t
63 pa
Fib :Allowable
4,147.20 psi
147 20
Load Comb:
1.200«1.605 Ik
15x12
�
Max tv/FvRafio=
0.126:1
1e.on
N : Actual :
5784 psi at 15.044]1 It in Span # 1
-
Fv Allowable :
457.92 psi
Load Comb:
+1200 1605
Load Comb
-1.200«1.60S
Deflective
Max Reactions (k) Q L Lr a IN € H
Transient Dowwwad 0.170 in Total Downward
0126 in
Left Support
0.26 0.51 O ]]
Ratio 1132 Ratio
849
Right Support
0.31 063 0.94
LC: S Only LC:+NS
Ratio
1305
Right Support
Transient Upward 0.000 in Total Upwad
0.000 in
LC: S Only
Ratio 9999 Ratio
9899
LC:
LC:
Wood Beam Design: 3rd Car Garage Door Header
Ratio 9999
CalcuMtiona per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size:
3.5x12, GLB, Fully Braced
LC'.
Using Load ReaisMnce Factor Design with IBC 2018 LOW Combinations, Miller Alis Bending
LC
Wood Spaces:
DF/DF
Wood Grade : 24F - V4
Fb- Tension
2,400.0 psi Fc -P#1 1,650.0 psi Fv
2650 psi Ebert -Ice lagoons Density
32.210pd
Fb-Comer
1,850.0 psi Fc - Peep 650.0 psi Ft
1, 1000 psi Eminbend -xx 930.Oou
Aooliel Loads
Un# Load: D = 0.0150, Lr= 0.030, 5 = 0.0450 lint, Tnb= 12.0 It
Design Summary
_
o) .tact 0.aeo�sLsw�
Max fb/Fb Ratio
= 0.298. 1
fb Actual-
1,234.29 Psi at
40004 in Span 01
Fb : Allowable:
4,147.20 psi
two Comb :
.1.20DL1 60S
3.5112
Max fv/FVRae0=
0.254:1
fv'. Actual :
116.23 psi at
0.000 ft in Span is 1
eon
Fv Allowable :
457.92 psi
_
Load Comb:
+1200 1605
s
Max Reactions (k)
o y Lr
$ w € H
Transient Doe aad 0.055 in
Total Downward
0.074 in
Left Support
0.72 144
2.16
Ratio 1740
Ratio
1305
Right Support
0.72 144
2.16
LC: S Only
LC +D.S
Transient Upward 0.000 in
Total Upward
0.000 in
Ratio 9999
Ratio
9999
LC'.
LC
NL Olson 8 Associates, Inc.
Project Title:
2453 Bethel Ave.
Engineer
PO Box 637
Project ID:
Port Orchard. WA 98366
Project Dew
(36 0) 876-2284
Multiple Simple Beam L-
LIC4 xW�MO15856 Bui1tl20.222.9 OLSON aA550CNTE5 fq ENBYGL 1 1Ba32022
Wood Beam Design
Garage Floor Beam
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7.16
BEAM Size: 5.5x15, GLB, Fully Braced
Using Load Resistance Factor Design with IBC 2018 Load Cantimations, Major Axis Sending
Wood Species '. DF/DF Wood Grade: 24F -V4
Fe- Tension 2,400.00 Fc - PRI 1,650.0 psi Fv 2650 psi Eoeid-ori 1.800.0 ksi Dens" 32210 pcf
Fb -Compr 1,850.0 psi Fc - Parry 650.0 psi Ft 1,100.0 psi Eminj-ia 930.0 is,
Apposed Loaeds
Unit Load: D=0.0120, L= 0.040 kI8, Tdb= 9.08
Unit Load: D=0.0150, U=0.030, S=0.0450 k/ft, 11.750 to 19.250 ft, Trio- 19.0ft
1Pomt: D=1.550, U=3.10, S=4.650k@11.330ft
Design Summary - -
Maxfb/FbRatio = 0.866 1 oo.roao Lp.aso ozaso o.s O sossso
Po : Actual'. 3.452.64 Ps( st 11 358 ft in Span N I
Ft. Allowable: 3,986.94 psi
Load Comb. .110D.0 SOLO 60S ` 5.5i1a
Max fv/FvRatio= 0.523:1 ts.zson
fir. Actual
239.39 psi at 17.774 fl in Span 91
Ratio
329
Fv Allowable:
457.92 psi
Taal Upw2id
0000 m
Load Comb'.
+1.20D+0.50L+1+60S
-- fAuDelfections
LC
Max Reactions
(k) D 1: Lr a W t
R Transknt Downwad
0.422in
Left Support
2.09 3.47 2.11 3.16
Rano
547
Right Support
3.67 3.47 5.27 7.90
LC:
S Only
Transient Upwind
O.000m
Ratio
9999
Actual'
LC.
Wood Beam Design: 3rd Car Garaqe Flwr Beam
Taal Downward
o700 in
Ratio
329
LC:«D+O750L«0]50$
Taal Upw2id
0000 m
Ratio
9999
- -
LC
Calculations par NDS 2918, IBC 2018, CBC 2819, ASCE 7-16
BEAM Size: 3.5x18, GLB, Fully Braced
Using Load Resistance Factor Design with IBC 2018 Load Combinations, Major Axis Bending
Wood Species: DFIOF Wood Grade: 20-V4
Fb- Tension 2,400.00 Fc - PRI 1,650.0 psi Fv 265.0 psi Ebend-xx 1,8000 kill Density 32,210 pcf
Fb-Compr 1,850.0 psi Fc - Per, 650.0 psi Ft 1,100.0 psi Emintend-u 930.0 can
Applied Loads
Unit Load: D=0.0150, Lr=0.030, S=0.0450 k/fL 2.0 ft to 13.50 ft, Tnb=18.0ft
1Pant: 3=1.220, U=2.440, S=3.660k@2.Oft
Casson $ummary
fb/F R ' -
Mex b abed
- 0.656; 1
o O.zro o W) sled mo)
Po: Actual:
2719.07 PWf at
6210ft in Span 91
- -
Rb Allowable'.
4,147.20 psi
Load Comb.
.12011-1 60S
Max tv/FvActual alio=
asx n
Actual'
39psi1
337.39 psi at
OOOOfl in Span 9t
ta.wrt
F
Fv : Allowable.
457.92 psi
_
1
Comb :
Lx
«1200«7.60.5
- Hr. ax De ions
R
Max Reactions (k)
L U
¢ W E
B Transknt DawrnvaN 0.235 in
Total Downward
0.313 in
Left Support
2.36 3.72
,
7.09
Ratio
Ratio
518
Right Support
1.96 3.93
589
LC'. $Only
my
LC: «p+$
Transient Upward
0.000 in
Total Upwnd
O.ODO in
Ratio
9999
Ratio
9999
LC
LC
NL Olson &Associates, Inc.
Project Title:
2453 Bethel Ave.
Engineer:
PO Box 637
Protect ID:
Port Orchani, WA 98366
Project Desc[
IWO) 876-2284
Fb- Tension 2,400.0 psi Fc -Pdl 1,650.0 psi Fv
Multiple Simple Beam
32210 pct
LIGN KWA6015858 Bu,id 202229
OLSON B ASSOCIATES 19) ENERCALC INC 19(321122
Wood Beam Design: Kitchen Floor Beam
Calculations per NDS 2018, IBC 2018, CBC 2018, ASCE 7-16
BEAM Size: 5.5x12, GLB, Fully Braced
Using Load Resistance Factor Design wan IBC 2018 Load
Combinations, Major Axis Bending
Wood Species DF/DF
Wood Grade - 24F - V4
Fb- Tension 2,400.0 psi Fc -Pdl 1,650.0 psi Fv
2650 psi Ebend-xx 1,800.0 ksi Density
32210 pct
Fb -Compr 1,850.0 psi Fc - Perp 650.0 psi Fl
1,100.0 psi Eminbend -xx 930.0 ksi
Applied Loatls
Unit Load D=0.0120, L=0.040 kM. Tito=1800
Design Summer
Max tb/Fb Ratio = 0.705; 1
D1)slao L1o.T2o! -
-
It, Actual : 2,922.63 psi at 6.750 ft m Span 81
To Allowable: 4,14720 psi
two Comb: 1.200+160L
5.5x12
A
Max fv/FvRatio= 0.403:1
135an
N: Actual'. 184.74 psi at 12.510 ft in Span 81
-
-
Fv : Allowable 457 92 psi
Load Comb: +1.20D+160L
Max Deflections
Max Reactions (k) D L L+ 6 W E B
TransientDownward 0.379 in Total Downward
0.493 in
Left Support 1.46 4.86
Ratio 426 Rata
328
Right Support 146 4.86
LC:L Only LC:+Dl-L
Transient Upward 0.000m Total Upward
0.000 in
Ratio 9899 Ratio
9999
LC
LC:
Wood Beam Design: Kitchen Floor Beam
calculations per NDS 2018, IBC 2018, CBC 2018, ASCE 7-16
BEAM Size: 5.5x15,
GLB, Fully Braced
Using
Load Resistance Factor Design with IBC 2018 Load Combinations, Major Axis Bending
Wood Species: DF/DF
Wood Grade: 24F -V4
Fb- Tension 2,400.0 psi Fc - Pill 1650.0ps1 Fv
265,00 Ebend-ia 1,800.0 fall Density
32210 pd
Fb-Compr 1.850.0 psi Fc -Perp 650.0 psi Ft
1,100.0 psi Emirbend - or 930.Oksi
Aochad Loatls
Unit Load: D=0.0120, L= 0.040 Wit. Tob= 18.08
1Pdm: D=1840, L = 6.120 k @ C50 It
Desitin Summerry
Max lb/Fb Ratio = 0.906;1
IXp.21W) Llo.n01.
to Actual'. 3,757.20 ON at 4.500 ft in Span i 1
— -
Flb Allowable 4.147.20 psi
Load Comb *1.20DN60L
asxm
Max fv/FvRatio= 0.628:1
lase a
4`
H Actual 28247 psi at 0.000 ft in Span il 1
__
Fv Allowable 457.92 psi
Load Comb. .1 20D+1 601
Mas, Dalliactions
_
Max Reactions (k) D L L7 a w E tl
Transient DownwaN 0362m Total Downward
0.471 in
Left Support 2.68 8.94
Ratio 447 Ratio
3"
Right Support 2.07 690
LC: L Only LC: +D+L
Transient Upward 0.000 in Total Upward
0,000 in
Ratio 9999 Ratio
99%
LC
LC:
NL Olson 8 Associates. Inc.
Project Title.
2453 Bethel Ave.
Engineer:
PO Box 637
Project ID:
PortOrchartl. WA 98366
Project Desc[
(360)876-2284
Fb- Tension 900.0 psi Fc - PHI 1,350.0 psi Fv
Muldple Simple Beam
UCS MV -09015858. Build 20.2229 OLSON 6 ASSOCIATES (o) ENERCALC INC 19888022
Wood Beam Design: Patio Cover Beam
NDS 2018, IBC 2018, CBC 2016. ASCE 746
BEAM Size: 6x8, Sawn, Fully Braced
Using Load Resistance Factor Design with 18C 2018
Load Combinations, Major Axis Bending
Wood Species Douglas Fir -Larch
Wood Grace No
Fb- Tension 900.0 psi Fc - PHI 1,350.0 psi Fv
180.0 psi Ebentl-xx 1,600.0 M, Density
32.210 pd
Fb-Comer 900.0 psi Fc -Pejo 625.0 psi Ft
575.0 psi Eminbend -xx 580.0 M,
Aodred Loads
Un'If Load D=0.0150, U=0.030, S=0.0450 Mft, Thb=6.Oq
Deakin Summery
Max Ratio = 0.646 7
0090 0.150 S 0270
Po'. AMM Actual at 1000 fl in Span i 7
1:M005381,81
Allowable -. 1,555.20 psi
Lo Com
Load Comb +1.200+1.605
Al
Max tv/FvRatio = 0.214: 1
a o n
N : Actual : 66.50 psi at 0.000 ft in Span # l
-
Fv : Allowable, 311.040
Load Comb'. .1 20D+1.605
'ons
Max Reactions (k) o L Lr ¢ w E tl
Transient Downward 0.081 in Total Downward
0.108 in
Left Support 0.36 0.72 1.08
Ratio 1187 Ratio
8go
Right Support 0.36 072 1.08
LC:S Only LC:+O«S
Transient Upward O.000in Total Upward
O.DOO in
Ratio 9989 Ratio
9899
LC
LC'
Wood Beam Design: Porch Cover Beam
CalcuWa per NDS 2078, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size: 8x10, Sawn,
Fully Braced
Using Load Resistance
Factor Design with IBC 2018
Load Combinations, Major Ares Bending
Wood Species: 0ougks Fr - Larch
Wood Gratle Not
Flo -Tension 900.0 psi Fc - PHI 1,3500 psi Fv
180.0 psi Ebend-xx 1.600olao, DeiaBy
32210 Pa
Fb-Connor 9000 psi Fc - Perp 625.0 psi Ft
575.0 psi Eminbend - x. 5WOksi
A000ed Leeds
Ung Load: D=0.0150, Lr=0.030, S= 0.0450 Will, Tnb= 3.0ft
Desion Summary
Max fb/Fb Ratio = 0.587; 1
D(aoa60) V(p_09o) s(0.1360)
fb Actual 913.48 Pw at 6.830 ft m Span # 1
Fb: Allowable: 1,55520 psi
exto
Load Comb'. 1.20D+1.605 r
Max fv/FvRatio = 0.151:1
13'560 n
N : Actual -. 46.94 psi at 12.886 It in Span # 1
-
-
Fv Allowable : 311.04 psi
_
Load Comb'. +1.20D+1.60S
Max -Deflections
Max Reactions (k) 12 L U 5 w E X
Transknt Downward 0.169m Total Downward
0.225 in
Left Support 0.31 061 0.92
Ratio 969 Ratio
727
Right Support 0.31 061 0.92
LC S Only LC'.+D+S
Transient Upward 0.000 in Taal Upward
0000 in
Ratio 9999 Ratio
9999
LC
LC
NL Olson 8 Associates, Inc.
Project Title:
2453 Bethel Ave.
Engine[
PO Bax 637
Project ID:
Port Orchard. WA 0366
Project Descr:
(360) 876-22M
2650 psi Ebxd-xx 1,800.0 ksi Deiwky
Muplple Simple Beim PA*WF6:NLDMM*Lod8
LICA. KW -06015858. BUIB202229 OLSON B ASSOCATESIc)ENERLALC INC 180}2022
Wood Beam Design: Roof Header
Cakub6ais Par NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size: 5.5x9, GLB, Fully Braced
= 0.500; 1
b Actual
Using Load Resistance Factor Design with IBC 2018 Load Combinations, Major Axis Bending
Flb Allowable :
Wood Specks: DFDF
Wood Grade: 24F -V4
♦1.20D.I60L
FD - Tension 2,40 .0 psi Fc - Pal 1,650.0 psi Fv
2650 psi Ebxd-xx 1,800.0 ksi Deiwky
31.20 Pcr
Fb-Comer 1,850.0 psi Fc - Perp 650.0 psi Ft
1,10.0 psi Eminbend -xx 950.0 ksi
31104 psi
ApoOed Loads
♦1,20DO.5L
Max Reactors (k)
Unit Load D=0.0150, U=0.030, 5= 0.0450 kIit. Tn0= 18.00
Left Support
0.40 1.32
Desion Summery
040 1.32
Max fb/Fb Ratio = 0.639; 1
olono/Lgoz40)s(a eto)
H Transient Dowmwartl 0,035m
2'. ACNal : 2,650.91 Psi at 4.50 6 in Span R 1
OMS in
Fb Allowable 4, 147.20 psi
2051
Ratti
Load Comb: i1.20D«1605
5.5x9
Max N/FVRatio= 0,405:1
90"
LC: +WL
N Actual "5560 at 8,280ft m Span a 1
Transient Upward
0.00in
Fv Allowable -. 457.92 psi
000 in
LoW Comb: «1200.1605
Miss Deflections
Ratio
Max Reactions (k) 4 L Lr S W E 11
Transient OPanrwald 0.20in Total Downward
0287 in
Left Support 1.22 2.43 3.65
Ratio 540 Ratio
405
Right Suppod 1.22 2.43 3.65
LG S Only LC:
-MS
Transient Upward 0.00 in Total Upward
0.000 in
Ratio 799 Ratio
9989
Wood Beam Design
Wood Species'. DougasF
Fb- Tension 90.
Fb-Comer 90.
Applied Loads
Unit Load: D = 0.0120, L
Oesion Summery
CBC 2019, ASCE 7-16
Resistance FaL1m Design with IBC 2018 Load Combinations, Major Axis Banding
- Larch Wood Grade No.2
psi Fc - Pal 1,35 .0 psi Fv IWO psi Elmnd-xx 1,60.0lest Density 32.210 per
psi Fc - Perp 625.0 psi Ft 5750 psi Eneatend-nr 5800bi
0.040 kM, Tab= 11.00
Max fb/Fb Rata
= 0.500; 1
b Actual
933.04 Psi at
Flb Allowable :
1,866.24 psi
Load Comb:
♦1.20D.I60L
Max fv/FvRatio =
0.288: 1
N: Actual
89.5 psi at
Fv Allowable:
31104 psi
Load Comb:
♦1,20DO.5L
Max Reactors (k)
e L U
Left Support
0.40 1.32
Right SupWa
040 1.32
DID.lszo L{o.Wpf
3.000 ft in Span ti
4.10
5.2400 in Span 91
F.
soft
Alai De ons
$ W E
H Transient Dowmwartl 0,035m
Total Downwartl
OMS in
Ratio
2051
Ratti
1585
LCL Only
LC: +WL
Transient Upward
0.00in
Total UPwartl
000 in
Ratio
9999
Ratio
9999
LC
LC:
NL Olson 8 Associates, lnc.
2453 Bethel A"
PO Box 637
Port Orchard, WA 983W
(360)876-2260
Muldpie Simple Beam
Project Title:
Engineer:
Project ID:
Project Descr:
P*dFb NW2009KOM
LICIL xw436015858, Bu020.22.29 OLSON a ASSOCIATES (C) ENERCALC INC 191P-M2
Wood Beam Design: Crawl Floor Joist
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
BEAM Size: 2:10, Sawn, Fully Braced
Using Load Resistance Factor Design with IBC 2018 Load Combinations, Major Axis Bending
Wood Species'. Hem Fir
Wood Grade: Not
Fb- Tension 850.0 psi Fc -PAI 1,300.0 psi Fir
150.0 psi Ebeilb xx 1,300.Oksi Density 2770 pct
Fb -Compr 850.0 poi Fc -Perp 405.0 psi Ft
525.0 psi Eminbend -xx 470.Oksi
Ag ied Loads
Unit Load D=0.0120, L=0.040 k%L Trio= 1.330ft
Design Summary
Max tb/Fb Ratio = 0.771 1
0(001596)4(o.OW20
in Actual - 1,433.15 Psi st 7.000 ft in Span # 1
Flb Allowable. 1,858.03 psi
Wad Comb'. a120D I60L
Max fv/FvRabo = 0.272: 1
14 o a
h: Actual'. 70.49 psi 913253ft in Span #1
Fv : Allowable : 259.20 psi
Load Comb'. 020Da1601
Max DeBections
Max Reactions (k) 12 5 Lr 5 w E H
Transient Dowmwad 0.359 in Total Downlvwd 0.167 in
Left Support 0.11 0.37
Ratio 187 Rett 359
Right $UPW 0.11 0.37
LC: L Only LC: +D+L
Transient Upward 0.00Oin Total Upward 0.000 in
Ratio 9899 Ratio 9999
LC, LC.
Wood Beam Design: Critical Window header
Cakuletiols per NDS 2018. IBC 2018, CBC 2019, ASCE 7-16
BEAM Size: {x10, Sawn, Fully Braced
Using Load Resistance Factor Design with IBC 2018 Load Combinations, Major Axis Bending
Wood Species: Hem Fir
Wood Grade: Not
Fb- Tension 850.0 psi Fc-PHI 1,300.0 psi Fv
150.0 psi Eberd-xx 1.300.011si Density 27.70 pct
Fb-Compr 850.0 psi Fc -Perp 405.0 psi Ft
525.0 psi Eminbend-xx 470.011si
Applied Loads
UnBLoad: D=0.0120, L=O.MOkIR.Tdb=9.0R
Unit Load: D=0.0150, U=0.030. S = 0.0450 k//L TN1=- 18.O ft
Deskn Summery
IXo.e )relB PL9aftpl_
Max ft)/Fa Ratio = 1.030 1
Actual'. 2,087S61151 at 3.000ft in Sean % 1
b
Fb :Allowable: 2,02894 poi
Load Comb'. a1.20.773:
410
1*1805 -
Maxt o= 0.7]3:1
N. Actual. 20026 psi at 5.240 R in Span # 1 -
dual.
eon
Fv :Allowable 25920 psi
F
Load Comb *1.20Ds1.20D+050L+1805
Max Deflectors
Max (k) g L k '�' E X
DowrwaN 0.079 in Total Downward 0.123k
Support
.
Leg Supped 1.13 1.08 1.62 2.43
Ratio
Ratio BOB Ratio 587
Rgh15upport 1.13 1.08 1.62 243
LC: S Only LC: apW.]SOLa0]50S
Transient Upward 0.000 in Total Upwind 0.000 in
Ratio 9999 Ratio 9999
LC: LC:
NL Olson 8 Associates. Inc.
Project Tele:
2453 Bethel Ave.
Engineer:
PO Box 637
Project ID:
Poe OrchaN, WA 98366
Project Del
(360) 876.2284
"now vq�vftv
P+gr[M4>Mase
LIp:KW-00tl15050. au1k110222.9
OLSON a ASSOIcAns (d ENERGLC INCIW}2022
DESCRIPTION: Garage Footing Pad
fc : Concrete 28 day strength =
Code References
Allowable Soil 8eamig =
Calculations per ACI 318.14, IBC 2018, CBC 2019. ASCE 7-18
Load Combinations Used: IBC 2018
Reinforcing
_
Genenl Information
ra- - w
Bars parallel to X -X Axis
Material Properties
Soil Design Values
fc : Concrete 28 day strength =
2.50 ksi
Allowable Soil 8eamig =
1.50 ksf
fy : Rebar Yied =
80.0 mi
Soil Density =
pd
Ec: Concrete Elastic Modulus =
3,122.0 ksi
Increase Bearing By Footing Weight =
No
Concrete Density =
145.0 pd
Soil Passive Resistance (for Sliding) =
2%0 pd
rp Values Flexure =
0.90
SoiVCon.w Friction Coef. =
0.30
Shear =
0750
Increases based on footing Depth
4 #6 Bars
Analysis Settings
Bandwidth Distribution Check (ACI 1544.2)
Footing base depth below soil surface =
It
Min Steel % Sending Reinf.
=
Allow pressincrease per foot of depth =
ksf
Min Allow % Temp Reinf.
= 0 00180
when bating base 6 below =
If
Min. Oveduming Safety Factor
= 1.0:1
Min. Sliding Safety Factor
= 1.0 - 1
Increases based on footing plan dimension
Add Ftg Wt for Soil Pressure
: Yes
Allowable pressure increase per foot of depth
Use Rg wt for stability, moments 8 shears
Yes
Applied Loads _
kid
Add Pedestal Wt for Soil Pressure
No
when maxlength a width is greater than
D
V
L S
=
fl
Use Pedestal wt for staGIOY, mom 8 shear
No
3.470 790
Dimensions
OB: Overburden =
Wath parallel to X -X Axis =
3.50 If
W. =
Length parallel to Z -Z Axis =
3.50 fl
Z
W. =
Footing Thickness =
12.0 in
k -fl
Pedestal dimensions...
x X
px parallel to X -X Axis =
in
- - - -
pz : pardlkel to Z -Z Axis'_
in
Height
in
Rebar Centedine to Edge of Concrete_.
at Bottom of footing =
3 0 in
a
z
Reinforcing
_
-
ra- - w
Bars parallel to X -X Axis
Number of Bars -
4.0
Reinforcing Bar Size = #
5
Bars parallel to Z Axis
Number of Bars =
40
-
Reinforcing Bar Size = Al
5
_j
4 #6 Bars
q
Bandwidth Distribution Check (ACI 1544.2)
-
DirectionRequiringCloserSeparatim
X -X
Section Looking to �Z—
------2YSecnan Loblilig to+X
We
# Bars required within zone
n/a
# Sam required on each side of zone
We
Applied Loads _
D
V
L S
W E N
P'. Column Load = 3 670
5.270
3.470 790
k
OB: Overburden =
off
W. =
k -f
W. =
k -fl
V -X =
k
V -z =
k
NL Olson 8 Associates, Inc.
Project Tile:
2453 Bethel Ave.
Engineer:
PO Box 637
Project
ID:
Port Orchard, WA 98366
Project
Descr
(MO)876-228E
General Footing
-
Rood Fk: MID
2aMt9tkac8
LICA KW -06015858. Buik1202229
OLSON B ASSOCIATES
(c) ENERCALC INC 19832022
DESCRIPTION: Garage
Footing Pad
DES/GNSUMMARY
•-
Min. Radio
Itarn
Applied
Capsily
Governing Load Combirutiw
PASS 0.7607
solideari
1.141 Ind
1.50 Net
.0+0 7501-+0,7505 about Z -Z axis
PASS Na
Overturning -X-X
0.0 k -R
0.0 kM
No Overtuming
PASS Na
Overturning -Z-Z
0.0 k -R
0.0 k -fl
No Overturning
PASS n/a
Sliding -X-X
O.Ok
0.0k
No Sliding
PASS Na
Sliding -Z-Z
0.0 k
00 k
No Sliding
PASS we
Uplift
0.0 k
0.0 k
No Uplift
PASS 0.1715
Z Flexure (+X)
2.347 k-"
13684 k -Pott +1 200+0.501-+1 60S
PASS 0.1715
Z Flexure (-X)
2.347 k4fl711
13.684 0VIL +120D+0.50L+1.605
PASS 0.1715
X Flexure (+Z)
2.347 k-R/ll
13.684 k-flM -1.20D+0.50L+1.605
PASS 0.1715
X Flexure (-Z)
2.347 k-8/8
13681 k-R/ft +1.20D+0.50L+1.605
PASS 0.1921
I-way Shear (+X)
14.407 psi
75.0 psi
+1.2OD-0.SOLO 60S
PASS 0.1921
1+4ay Shear (-X)
14.407 psi
75.0 psi
+1.20D+0.50L+1 WS
PASS 0.1921
1 -fray Shear (+Z)
14.407 psi
75.0 psi
+1 20D+0 ML+1 WS
PASS 0.1921
1 -way Shear (-Z)
14.407 psi
75.0 psi
+1 20D+O.S0L+1.605
PASS 0.36T7
2- y Punching
55.155 psi
150.0 psi
+1.20D+0.50L+1.605
Detailed Results
Soil Bearing
Rotation Axis a
Actual SWI Boring Strem
Q Location
Actual I Alleve
Load Comblrla8w...
Gross Allowable
(in)
Bolton, -Z
Top, +Z
Left, -X RUM, +X
Ratio
X -X, DOnly
1.50
Na 00
04446
04446
Na Na
0296
X-X,+D+L
1.50
n/a 0.0
0.7279
07279
Na Na
0485
X -X, +D+Lr
1.50
Na 0,0
0.8748
08748
Na Na
0 583
X -X, +D+S
1.50
Na 0.0
1.089
1089
Na Na
0 726
X4, +D+0.75OLr+0.750L
1,50
Na 0,0
0,9797
0.9797
Na Na
0 653
X-X,+D+0.750L+0.750S
150
Na 0.0
1.141
1.141
Na Na
0751
X-X.+0.60D
1 S
Na 0.0
02668
025M
Na Na
0178
Z -Z, DOnly
150
0.0 we
Na
Na
04446 0446
0296
Z -Z, +D+I
1.50
0.0 Na
We
Na
07279 0.7279
0485
Z -Z, +D+U
1.50
0.0 Na
Na
We
06748 0.8748
0.583
Z -Z, +D+S
1.50
0.0 Na
Na
we
1.089 1.089
0 726
Z-Z,+D+0.7WLn0.7WL
iW
0.0 Na
Na
Na
0.9797 0.9797
0653
Z -Z. +D+0.750L+0.750S
150
0.0 Na
Na
Iva
1.141 1.141
0 761
Z -Z. +0.60D
150
0.0 Na
We
Na
0.2688 0.2588
0 178
Overturning Stability
Rotation Axis 6
Load Combinative...
Overtumirg Momard
RaisBng Moment Stability Ratio
SMew
FwOrlg this NO Overturning
Sliding Stability
All units k
Force Applicatlw Axis
Load Conbination...
Sliding
Force
Rested" Force Stability Ratio
status
Fooling Has NO Sliding
Footing Flexure
Flexon Axis6Lwtl Combirwtive Mu Side
Tension kReR'd
Gvm. As
AcWal As PM'Mn
6tatas
k -fl
Suffaw
in"2
in'2
irrA2 k -fl
X-X.+140D
0.6423
+Z
Bottom
0.2592
Ashlin
0.3543 13684
OK
X -X+1.400
0.6423
-Z
Bottom
02592
AsMm
0.3543 13684
OK
X-X,+1.20D+O.SOLr+1.60L
1.574
+Z
Bottom
0.2592
Ashlin
03543 13.694
ON
X-X,+1.20D+0S0Lr+1S0L
1.574
-Z
Bottom
02592
AsMin
0.3543 13.684
OK
X4,+1.20D+760L+O. SOS
1,738
+Z
Bottom
02592
AsMin
0.3543 13,694
OK
X-X,+1.20D+160L+0. SOS
1738
-Z
Bottom
02592
AsMin
0.3543 13654
OK
X-X,+1.200+16011+0.50L
1.821
+Z
Bottom
02592
AsMin
0.3543 13694
OK
X-X+1.20D+1WLr+O. 50L
1.821
-Z
Bottom
02592
AsMin
0.3543 13684
OK
X -X.+1.200+1 WLr
1,605
+Z
Bottom
02592
AsMin
0.3543 13.684
OK
X-X.+1.20D+1.SOL,
1.605
-Z
Boom
02592
AsMin
03543 13.684
OK
X -X, +120D+0 501+1,60S
2.347
H
Bottom
0.2592
AsMin
0.3543 13.684
OK
NL Olson 8 Assooales, Inc.
Project Title:
2453 Bethel Ave.
Engineer:
PO Box 637
Project ID:
Port OrchaN. WA 98366
Project Descr:
(MO) 876-2284
k-8
General Footing Pstied Fit N D2585B14.acS
JCP M-06015850.13UMM2229 01- 0NSA5 CNTE$ (c(ENERCALC INC 19032022
DESCRIPTION: Garage Footing Pad
Footing Flexure
Resume e Axis S, Load Combination
Mu
Skis
Tension
As Rood
hm. b
Actual As
Phi•Mn
3.94 psi
k-8
3.94 psi
Surface
ii
in 2
W2
k-8
X-X,+1,20D+0.50L-160S
2.347
-Z
Bottom
02592
ASMin
03543
13.BB4
X -X,+1.200+1.605
2.131
+Z
Bottom
0.2592
ASMin
0.3543
13684
X-X.+120D+1.605
2.131
.Z
Bottom
02592
ASMin
0.3543
13.684
X -X. +1.20D+0.50Lr+0.50L
1 097
+Z
Bottom
0.2592
ASMin
0.3543
13.684
X-X.+1.20D+o.50Lr+0.50L
1.097
-Z
Bottom
0.2592
MMin
0.3543
13.684
X-X,+120D+O.SOL+0.505
1.261
+Z
Bottom
0.2592
ASMin
0.3543
13.684
X-X,+120D+0.50L+O.50S
1.261
-Z
Bottom
0.2592
ASMin
0.3543
13.680
X -X, +1 20D+0 -50L+0 70S
1.459
+Z
Sodium
0.2592
ASMin
03513
13.684
X-X,+120D+0-50L+O.70S
1459
-Z
Bottom
0.2592
ASMin
0.3543
13.654
X -X,+0.901)
04129
+Z
Bottom
0.2592
ASMin
0.3543
13654
X -X,+0.900
04129
-Z
Bottom
0.2592
AsMin
0.3543
13634
Z2. +1,40D
0.6423
-X
Bottom
02592
ASMin
03543
13.664
Z -Z,+1.401)
0.6423
+X
Bottom
02592
ASMin
0.3543
13.684
Z-Z.+1.20D+O.SOLr+1.60L
1.574
-X
Bottum
0.2592
ASMin
0.3543
13654
Z-Z,+1.20D+0-50Lr+1.60L
1.574
+X
Bottom
0.2592
ASMin
0.3543
13.684
Z-Z,+1.20D+160Le0-50S
1.738
-X
Bottom
0.2592
ASMin
0.3543
13.684
Z-Z,+1.20D+160L+0. 50S
1738
+X
Bottom
0.2592
MMin
0.3543
13,684
Z-Z,+120D+1.60Lr+0.50L
1.821
-X
Bottom
0.2592
ASMin
0.3543
13.684
Z-Z,+1.20D+1.60Lr+0.WL
1.821
+X
Bottom
0.2592
ASMin
03543
13.684
Z-4 +11011>0.601r
1.605
-X
Bottom
0.2592
ASMin
03543
13.684
Z-Z,+1.20D+1.60Lr
1.605
+X
Bottom
0.2592
ASMin
0.3543
13.684
Z4,+120D+0.50L+1.605
2.347
-X
Bottom
0.2592
ASMin
0.3543
13.684
ZZ,+120D+0.50L+1.605
2.347
+X
Bottom
0.2592
iismxn
03513
13.654
ZZ,+120D+1.60S
2.131
-X
Bottom
0.2592
ASMin
0.3543
13684
Z2, +1 ZOD+1.60S
2.131
+X
Bottom
02592
ASMIn
0.3543
13.6134
ZZ,+1.20D+0.50Lr+060L
1.097
A
Bottom
02592
ASMIn
03543
13,684
Z-Z,+1.20D+0.50Lr+0.50L
1097
+X
Bottom
02592
ASMIn
0.3543
13.664
ZZ,+1.20O+0.50L+0.505
1261
-X
Bottom
0.2592
ASMin
0.3543
13.684
ZZ,+1.20D+O.WL+0.505
1261
+X
Bolton
0.2592
ASMin
0.3543
13,684
Z-Z.+1.20D+0.50L+0JOS
1,459
-X
Bottom
0.2592
ASMin
0.3543
13.684
ZZ,+120D+030L+0.70S
1.459
+X
Bottom
0.2592
ASMin
0.3543
13.684
Z-4 +0,90D
04129
-X
Bottom
02592
ASMin
0.3543
13.684
Z-Z,+0.90D
04129
+X
Bottom
0.2592
ASMin
0.3543
13684
One Way Shear
Status
Load Combina0oa...
Vu@ -X Vu@+X
Vu6S Vue+Z Vu:Max
Phi Vn Vu I PhrVn Stals
+140D
+1.400
3.94sid
3.94psi
3.94 psi
341 psi
3.94 psi
75.00 psi
0.05
OK
+120D+O. SOLI+1.60L
9.Saw
966psi
966 psi
966 psi
9.66 psi
75.00 psi
0.13
ON
+1.20D+160L+0.505
1067 psi
10.67 psi
1067 psi
1067 psi
1067psi
75.00 psi
0.14
OK
+1200+1 60Lr+O.50L
11.18psi
11.18 psi
11 lapin
11A8psi
11.18psi
75.00 psi
0.15
OK
+120D+i.601r
9.85mi
9.a5 psi
9.85 psi
985 psi
9.85psi
75.00 psi
0.13
ON
+1.20D+0.50L+1.605
14.41 Psi
14.41 psi
14.41 psi
14.41 psi
14.41 psi
75.00 psi
OAS
OK
+120D+160S
13.08 psi
13.08psi
13.08 psi
13 DB psi
13.08 psi
75.00 psi
0.17
OK
+120D+0.50Lr+0.50L
6.73 Psi
6.73 psi
6.73 psi
6.73 psi
673psi
75.00 psi
0.09
OK
+1.20D+0.50L+0-50S
774 PSI
7.74 psi
774 psi
7.74 psi
774psi
75.00 psi
0.10
OK
+120D+0.50L+0.705
8.95 psi
8.95psi
8.95 psi
8.95 psi
895psi
75.00 psi
0.12
OK
+090D
2.53 Psi
2.53 psi
2.53 psi
2.53 pv
2530
75.00 psi
0.03
ON
Two -Way "Punching" Shear
All units k
Load Combina8on...
Vu
PMNn
VU I P19Vn
+140D
15.09 Pv
150.00Ps1
0.1006
+120D+O.SOLr+l60L
36.98 psl
150O0psi
02465
+1.201>0.60L+0.505
40.84 psi
150.00Psi
02723
+1.20D+1.60Lr+050L
42.80 psi
150.00psi
0.2853
+1.20D+1.60Lr
37.70 psi
150.00psi
02513
+1.20D+0.50L+1.605
55.16 psi
150.00psi
0.3677
+1.20D+1.60$
50.06 psi
150.00m,
0.3337
+1.20D+0.50Lr+0.50L
25.77 psi
150.00psi
0.1718
+1.20D+0.50L+0.SOS
29.63 psi
150O0psi
0.1975
+1.20D+0.SOL+070S
34.27 psi
150.00ps1
02285
+0.90D
9.70 psi
150.00psi
0.06467
Sisbn
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
NL Olson 8 Aesoaates. Inc.
Na
Project Title:
2453 Bethel Ave.
6.0
Engineer:
4
PO Box 637
Na
Project ID:
6.0
Pod Orchard, WA 98366
4
Project Descr.
(360) 8762284
D
Lr L S
W E H
Lice -0r015r59, Bwd.2p.22.28
OLSON B ASSOCAnS
lc1 ENERCALC INC 1aso 1p22
DESCRIPTION: Porch/Patio Cover Beam
OB -. Overburden =
Code Re/erences
ksf
W. =
Calculations per ACI 318.14, IBC 2018, CBC 2019, ASCE 7-16
fl
M-zz =
Load Combinations Used: IBC 2018
kit
V -x =
General Infonnation
k
V -z =
Material Properties
Soil Design Values
fc Concrete 28 day strength =
2.50 ksi
Alkraabk Soil Bearing =
1.50 kid
fy: Reber yield =
60.0 ksi
Soil Density =
pcf
E. Conaete Elastic Modulus =
3,122.0 ou
Increase Bearing By Footing Weight =
No
Concrete Density =
145.0 pof
Soil Passive Resistance (for Sliding) =
250.0 pct
W Values Flexure =
0.90
SoiXoncrete Friction Coeff. =
0.30
Shear =
0.750
Increases based on footing Depth
Analysis Settings
Footing base depth below soil surface =
fl
Min Steel % Bending Reim.
=
Allow press increase per foot of depth =
kat
Min Allow % Temp Reed
= 000180
when footing base is below =
fl
Min. Overturning Safety Factor
= 1.0 : 1
Min. Siding Safety Factor
= 1.0 :1
Increases based on foodng plan dimension
Add Ftg Wt for Soil Pressure
yes
Allowable pressure increase per foot of depth
Use flg wt for stability. moments 8 shears
Yes
=
iter
when max. length or width is greater than
Add Pedestal Wt for Soil Pressure
No
=
It
Use Pedestal wl for stability, mom &shear
No
Dimensions
Width paallel to X -X Axis =
2,0 It
Length parallel to Z -Z Axis =
2.0 R
Z
Footing Thickness =
24.0 in
Load location offset from footing center._
ez Pdl to Z -Z Axis =
6 in
=
in
Pedestal dimensions ...
px paralblto X -%Axis = in
pz'. parallel to Z -Z Axis = in
Height in
Rebar Centerline W Edge of Conodite._
at Bottom of rooting = 3.0 in
Reinforcing
Na
Be. paallel to X -X Axis
Number of Ban -
6.0
Reinforcing Bar Size = #
4
Bars parallel to Z -Z Axis
Na
Number of Bars =
6.0
Reinforcing Bar Size = e
4
Bandwidth Distribution Check IACI 15.4.4.21
Direction Requiring Closer Separation
D
X x
Z p
ZV w
O
V
6-#4 Bars 6-#4Bars
Na
e Bars required within zone
ma
X -X Section Locliongto+Z
Z -Z Section Looking to+X
s Bars required on each side of zone
Na
Applied Loads
---
D
Lr L S
W E H
P: Column Load =
0.360
0 -20 1 080
-110 k
OB -. Overburden =
ksf
W. =
fl
M-zz =
kit
V -x =
k
V -z =
k
NL Olson 8 Associates. Inc.
Project Title.
2453 Bethel Ave.
Engineer.
PO Box 637
Project ID:
Pon Orchard WA W366
Project Deur:
(3601876-2284
MjMtRK.NM2MM OS
L1Ca KW-06015858.euik1202229
OLSON S ASSOCIATES
(q ENEKLLL INU Ivv3 P3
DESCRIPTION: Porch/Patio Cover Beam
DESIGN SUMMARY
• •
•
Min. Ratio
Mem
Applied
Capacity
Govarnhg Load Combination
PASS 0.790
Soil Bearing
1.185 led
1.60 led
-D-S about X -X axis
PASS 1,030
overturning -X-X
0.990 k -ft
1020 k -ft
-0 600+0
PASS Na
Overturning -Z-Z
0.0 k -ft
0.0 k -ft
No Overturning
PASS Na
Sliding -X-X
OO I,
0.0k
No Sliding
PASS Na
Sliding -Z-Z
00k
0.0 k
No Siding
PASS 1.382
uplift
-0.660 k
0.9120 k
+050D+O.6OW
PASS 0.004928
Z Flexure (+X)
0.270 k-ft/ft
54.794 k-fVft
+1,20D-1 60S
PASS 0.004928
Z Flexure (-X)
0.270 1,41,111
54.794 k -BIM
+120EW 60S
PASS 0.002771
X Flexure (+Z)
0.1519 1,4e/11
54.794 k-ftft
N 20D+l 60S
PASS 0.005359
X Flexure (-Z)
02936 k-RHt
54.794 k-ftlft
+OA0D+W
PASS Na
1 -way Shear (+X)
0.0 psi
75.0 psi
Na
PASS 0.0
1.Nay Shear (-X)
0.0 psi
0.0 PSI
Na
PASS Na
1 -way Shear (+Z)
0.0 psi
75.0 psi
Na
PASS we
1- y Shear (-Z)
0.0 psi
75.0 psi
we
PASS Na
2 -way Punching
9.701 psi
75-0 psi
+1A00
Detailed Results
Soil Bearing
Rotation Axis 8
Race Zboc
Achsl
Soil Bearing Senate III Location
Actual / Albv
Load Combination...
Gross Allowable
(n)
Bell -Z
Tap. +Z
Left. -X Right +X
Ratio
X -X, D Only
1.50
Na 1 421
0.2464
0.5137
Na Na
0 343
X-X,+D+Lr
1.50
Na 2.893
0.1591
09610
Na Na
0641
X -X, +D+S
1.50
Na 3.323
0.1154
1.185
Na Na
0 790
X-X,+D+0.75OLr
1.50
Na 2621
0.1809
0.8491
Na Na
0.566
X -X. +D.O.750S
1.50
Na 3.013
0.1481
1,017
Na No
0678
X-X,+D+O.fiDW
1.50
Na -2.093
0.3264
0.1036
Na We
0218
X4,+D+0.750Lr+0.45OW
1.50
Na 1.553
0.2409
0.5416
Na Na
0361
X -X +D+0.7WS+045OW
1.50
Na 2207.
0.2082
0.7093
Na Na
0473
X-X,+0.600+0.60W
1.50
Na -10.571
0,6858
0.0
Na Na
049
X-X.+0.60D
1.50
Na 1.421
0.1478
0.3082
Na Na
0206.
Z -Z, D Only
1,50
0.0 Na
Na
Na
0.380 0.3W
0 253
Z-Z.+D+Lr
1.50
0.0 Na
Na
Na
0.560 0.560
0.373
Z-Z.+D+S
1.50
0.0 Na
Na
Na
0650 0.650
0433
Z -Z, +0+0.75OU
1.50
0.0 Na
Na
Na
0.5150 0.5150
0 343
ZZ,+D+0.750S
1.50
0.0 Na
Na
Na
0.5825 0.5825
0388
Z-Z,+D+0.60W
1.50
0.0 Na
Na
Na
0.2150 0.2150
0143
ZZ,+D+0.75OLr+0.45OW
1.50
00 Na
Na
Na
0.3913 0.3913
0261
Z-Z,+D+0.750S+045OW
1.50
0.0 we
Na
Na
04588 0.4588
0.306
Z-Z.+0-6OD-0.6DW
1.50
0.0 Na
No
Wa
0.0630 0.0630
0.042
ZZ. +040D
1.50
0.0 Na
we
Na
0.2280 0.2280
0 152
Overturning Stability
Rotor Axle&
Load Conbbatinn...
OrMuming Moment
Realsting
Mnmerrt
Stability Ratio
Status
X -X, D Only
None
170 kA
Infinity
ON
X-X.+D+Lr
None
2.750 k -ft
Infinity
ON
X-X,+D+S
None
3.320 k-11
Infinity
ON
X-X,+D+0.750Lr
None
2.510 k -ft
Infinity
OK
X-X,+D+0750S
None
2.915 k -ft
Infinity
ON
X-X,+D+OA()W
0.990 k -ft
1.70 k -ft
1717
OK
X-X,+D+0.75OLr+045OW
0.7425 k -ft
2.510 Irit
3.380
ON
X -X, +D+0.750S+0 450W
0.7425 k -ft
2.915 k -ft
3.926
ON
X -X. +0.60D+O.60W
0.990 k -ft
1.020 k -ft
1,030
OK
X-X,+060D
None
1.020 k -ft
Infinity
OK
Z -Z. D Only
None
00 k -ft
Infinity
OK
Z-Z.+D+Lr
None
0.0 k -ft
Infinity
OK
Z-Z.+O+S
None
0,10 k -ft
Infinity
OK
Z-Z,+Io0.7WU
None
00k -ft
Infinity
OK
Z-Z,+D+0.750S
None
00k -ft
Infinity
OK
Z-Z,+D+0.60W
None
0.0 k -ft
Infinity
OK
NL Olson 8 Associates, Inc. Project Title
2453 Bethel Ave.
Engineer
PO Box 637
Project
ID:
Pod OrchaN, WA 98366
Project Descr.
(360) 8762284
General Footing
PraYrtro.
UCa KW00015950. Build 202229
OLSON B ASSOCWTES
(c)iaii CLC INC 190SX@2
DESCRIPTION: Porch/Patio
Cover Beam
Overturning Stability
Rotation Axis &
Load Combination...
OverWming
Moment
Resisting Moment
Still liry Ratio
stt
Z-Z.+D+0.7501-r.0450W
None
D.0 k-0
Indy
OK
Z-Z.+D+0.7505+0. 450W
None
0.0 1,41
Infinity
OK
Z-Z,+0600+0.Bow
None
0.0 k -d
Infinity
OK
Z -Z, +040D
None
0.0 kA
Infinity
OK
Sliding Stability
NI units k
Force Application Axis
Load Combination...
Sliding Force
Resle6ng Force
Stability Ratio
Status
Footing Has NO Sliding
Footing Flexure
Flexure Axis B Load Combination
Mu
Slide
Tension
AS Read
Blind. As Actual As
PhrMn
SW Ws
k -fl
Surface
irm
iM2
m`2
kit
X-X.+1.40D
0.03543
+Z
Bottom
0.5184
AJ,in
050
54.794
OK
X-X.+1.40D
0.03545
-Z
Bottom
0.5184
ASMin
050
54.794
OK
X-X.+1.20D+O. 501-r
0.05568
+Z
eottom
0.5164
iMJAm
0.60
54.794
OK
X-X.+1.20D+O.50Lr
0.05570
-Z
Bottom
0.5184
ASMin
O60
54.794
OK
X-X,+1.20D+0. SDS
0.06834
+Z
Bottom
0.5184
ASMin
060
54794
OK
X-X,+120D+0.505
0.06836
-Z
Bottom
0.5184
ASMin
060
54.794
OK
X-X.+1.20O+1.60Lr
0,1114
+Z
Bottom
0.5184
ASMin
0.60
54.794
OK
X-X,+120D+1.60Lr
0.1114
-Z
Bottom
0.5184
ASMin
060
54.794
OK
X-X,+120D+1.6OLr+0.50W
007270
+Z
Bottom
0.5184
ASMin
060
54.794
OK
X-X,+1.20D+1.60Lr+0. 50W
0.07272
Z
Bottom
0.5184
ASMin
060
54.794
OK
X-X.+1.20D+1.605
0.1519
+Z
Bottom
0.5184
ASMin
0.60
M.794
OK
X-X,+1.20D+1.605
0.1519
-Z
Bottom
0.5184
ASMin
0.60
54.794
OK
X-X.+1.20D+1.605+0.50W
0.1132
+Z
Bottom
0.5184
ASMin
0.60
54.794
OK
X -X. +1 20D+1 lil WIN
0.1132
-Z
Bottom
0.5184
ASMin
0.60
54.794
OK
X-X,+1.200+0.50Lr+W
0.02165
+Z
Top
0.5184
ASMin
0.60
54.794
OK
X-X,+1.20D+0.50Lr+W
0.02166
-Z
Top
0.5184
AsMin
0.60
54.794
OK
X-X,+1200+0.50S+W
0.008999
+Z
Top
0.5184
ASMin
0.60
54.794
OK
X-X.+1.20D+0.50S+W
0.009002
Z
Top
0.5184
ASMin
0.60
54.794
OK
X-X,+120D+0.705
0.08352
+Z
Bottom
0.5184
ASMin
0.60
54.794
OK
X-X,+1.20D+O.70S
0.08355
-Z
Bottom
0.5184
ASMin
0.60
54.794
OK
X-X,+0.90D+W
0.03263
+Z
Top
0.5184
ASMm
0.60
54794
OK
X-X.+0.90D+W
0.2936
Z
Top
0.5184
A Mhm
0.60
54.794
OK
X-X.+0.90D
0.02278
+Z
Bottum
0.5164
Mill
0.60
54194
OK
X-X.+0.90D
0.02279
Z
Bottom
0.5184
ASMm
060
54.794
OK
Z -Z,+1.400
0.0630
-X
Bottom
0.5184
ASMm
0.60
54.794
OK
Z-Z,+1.40D
0.0630
+X
Boom
0.5184
ASMIn
060
54.794
OK
Z-Z.+1.20D+0.50Lr
0.0990
-X
Bottom
0.5184
ASMm
0.60
54794
OK
Z-Z..1.20D+0.50Lr
0.0990
+X
Bottom
0.5184
ASMin
060
54J94
OK
ZZ.-1.20D+O.50.S
0.1215
-X
Bottom
0.5184
ASMin
0.60
54.794
OK
Z-Z,+1.20D+0.50S
0.1215
+X
Bottom
0.5184
ASMm
0.60
54.794
OK
ZZ,+1.201W.60Lr
0.1980
A
Boom
0.5180
ASMm
0.60
54,794
OK
ZZ, +1.201>+1.601r
0.1980
+X
Bottom
0.5184
ASMm
0.60
54.794
OK
Z-Z,+1.20D+1.60Lr+0.50W
0.1293
-X
Bottom
0.5154
AsMm
0.60
54.794
OK
ZZ,+120D+1.60Lr+0.50W
0.1293
+X
Bottom
0.5184
ASMin
060
54.794
OK
ZZ,+120D+1.605
0.270
-X
Bottom
0.5184
ASMin
060
54.794
OK
ZZ,+120D+1.BDS
0.270
+X
Bottom
0.5180
ASMm
060
54.794
OK
ZZ,+1.200+1.605+0. SOW
0.2013
-X
Booms
0.5184
ASMin
060
54.794
OK
Z-Z,+1.20D+1.60S+OSDW
0.2013
+X
Bottom
0.5184
ASMin
060
54794
OK
ZZ,+1.20D+D.50Lr+W
0.03850
-X
Top
0.5184
ASMin
060
54.794
OK
Z-Z,+1.20D+0.50Lr+W
0.03050
+X
Top
0.5184
ASMIn
060
54,794
OK
Z-Z,+120D+0-SDS+W
0.0160
-%
Top
0.5184
ASMm
060
54794
OK
ZZ,+120D+0.50S+W
0.0160
+X
Top
0.5184
ASMin
0.60
54.794
OK
ZZ, +1.20D+0.705
0.1485
-X
Bottom
0.5184
ASMm
060
54.794
OK
ZZ +1.20D+0]0$
0.1485
+X
Bottom
05184
MMin
060
54.794
OK
ZZ, +0.900+W
0.0970
-X
Top
0.5164
A Mm
060
54-794
OK
ZZ, +o.gaD+w
0.0970
+X
Top
0.5184
ASMin
060
54.794
OK
Z-Z,+0.90D
0.04050
-X
Bottom
0.5184
ASMin
060
54.794
OK
Z-Z,+0.90D
0.04050
+X
Bottom
0.5184
ASMin
060
54.794
OK
NL Olson 8 Associates. Inc.
Project Tithe
2453 Bethel Ave.
Engineer:
PO Box 637
Project ID:
Pod Orchard, WA 98366
Project Claim
(360) 876-2284
0.00 psi
[§ima1FootingP" JimFIKNID23NS ACO
LICS KWN015058 BUAP20221.9 WSON a ASSOCATE (c) ENERCALC INC 19038022
DESCRIPTION: Porch/Patio Cover Beam
One Way Shear
Load Combination...
Vue-X Vue+X Vue2 Vue+Z
Vu:Msa
Phi Vn Vu I PhPVn
StNus
+1.401)
0.001,91
0.00Psi
0.00 psi
0.00 psi
0.00 psi
75.00 psi
0.00
ON
+12013+0 501-r
0.00mi
O.00psi
0.00 psi
0,000
OOOpst
75.00 psi
0.00
OK
+1.20Dio SOS
O.00psi
0,00 psi
0.00 psi
0.000
0,00 psi
75.00 psi
0.00
OK
+1.20D+1.601 -r
0.00 Psi
0.00psi
0.00 psi
0.00 pu
0,00 psi
75.00 psi
0.00
OK
.1.2013+160Lr+0. 50W
0.001,61
OOOpsi
0.00 psi
0000
000psi
75.00 psi
000
OK
+1.20D+1.605
0.00psi
0.00 psi
0.00 psi
0,000
000psi
75.00 psi
0.00
OK
+1.20D+1.605+0.50W
0.00 Psi
OOOpsi
0.00 psi
0.0ow
0.00 psi
75.00 psi
0.00
OK
+1.20D+O.SOLr+W
0.00 psi
0.00psi
0.00 psi
0.00 pu
O.00psi
75.00 psi
0.00
OK
+1.nD+0.50S+W
0.00psi
O.00psi
000 psi
0.00 psi
0Oopsi
75.00 psi
0.00
OK
+1.20D+0.705
0.00 Psi
O.00psi
0.00 psi
0.00 pili
O.00psi
75.00 psi
0.00
OK
+0.90D+W
0.00 psi
0.00 psi
0.00 Psi
0000
O.00psi
75.00 psi
0.00
OK
+0.90D
0.00psi
OOOpsi
000 psi
0.00 psi
OOOpsi
75.00 psi
0.00
ON
Two�V ay "Punching" Shear
Ail units K
Load Combination...
Vu
Ph"n
Vu PNNn
St3Ws
+1.400
970 psi
150.00psi
008167
OK
+1.20D+O.5OLr
970 psi
150.00PV
006467
OK
+1.20D+0.50S
9.70 psi
15060psi
006467
OK
+1.20D+1.60Lr
9.70 psi
150.00psi
0.06467
OK
+1.20D+1.60Lr+0.50W
9.70 psi
150.00psi
0.06167
OK
+1.2013+1605
970 psi
150.00psi
0.06167
ON
+1.2013+1 605+0.50W
9.70 psi
150.00psi
0.06467
OK
+1.2013+0.50Lr+W
9.70 psi
150.00psi
0.0&67
ON
-1.20D+0.50S+W
970 psi
150.00psi
006467
OK
+1 20D+0
970 psi
15000psi
0.06467
ON
+0.901)+W
9.70 psi
150.00psi
0.00007
OK
+0.901)
9.70 psi
150.00psi
006467
OK
Appendix
Technical Topics
A Portal Frame
for Engineered
with Hold Downs
Applications
The APA portal -frame design, as shown in Figure 1, was envisioned primarily for use as bracing
in conventional light -frame construction. However, it can also be used in engineered applications,
as described in this technical topic. The portal frame is not actually a narrow shear wall because
it transfers shear by means of a semi-rigid, moment -resisting frame. The extended header is
integral in the function of the portal frame, thus, the effective frame width is more than just the
wall segment, but includes the header length that extends beyond the wall segment. For this
shear transfer mechanism, the wall aspect ratio requirements of the code do not apply to the wall
segment of the APA portal frame.
FIGURE 1
CONSTRUCTION DETAILS FOR APA PORTAL -FRAME DESIGN WITH HOLD DOWNS
FRONT ELEVATION
SECTION
Headw ro Iwk still
fiknt of Moder wit double ponol komes (leo braced wall porclsl
slog or wind do n
mot 10001bf on both
Faem of Fodef wit sm9k porrol home
(ore
sides al;rio
apposrk ude o�
8 oi,,wall ifn of o
2ro IB'rougowidlMW opening
shevihmg
'
no, sirpk or doble pwnl
Foden kinge sled to
Fo�vE`)a
-
Modef wiMb160
wall
4;='
neigh, _
FPdo .P PIa1e ro
I
-
h(=' with lwo rows
of Ibd dnkc noBz of
min. 3oI wood
- Fonen sheodr�rig ro Faader wit ad woman or
fol panel
12
gol.onrsed bas nails m 3' grid Patlern os shown
sMeotMinp
rMoi
to or
Moder b wbznd sn p per wind dmipn.
i If needed, pool splice
-11
o
Min 1000 �bl on hot s des of opening pposite
dyes shall or- ov er
height
sided sheothmg,
o
and be oikdn
on bbcl,mp
10'
- Min double 2r4 homing covered with in 3/8'
+thin miLdk 26' of
height. One
pow
Mirk woad sm,tlural pool sMelhrng w'^F
- -
....
al.leg
'
heght ..
- U ori or gdmmzad bw node of 3'.
rsfooved in godg
C.
.. in all Mi (dada, Iii -king, ort vIkl Irp.
poral edge.
Twical ponol Mni.
- Min knpM of pone) per route 1
condf.ble
_ mind. 2a.d)
-
Ikng aM iok dud)
'�- Min 2135o01b strap-e/pe 1wldxdor.m
number of I -ark sNds
(embdded iMo <onnele and oAed inro i,—NI
o6 IRC biles
R602.)I(6(2)-
,1,
r Min offs, Ldc �cr a" <J bni
1
ndlorting
iaP and bosom cl L .. . ;i....
I
The tb: Mold -down
I
I
may be Doled on M,e
1
I
I bpduide of Me
pwrol.home bating.
Mid-cicnini dei
lob -
emhdernnin
Min, 1) bmeon0or saper IRC R403 b -
fee and so
wM 2+2. 3/I6' Piro,wosM1e.
ran Fomingl
_ A Poral Frama with Hold Downs far Engineered Applications
TABLE 1
RECOMMENDED ALLOWABLE DESIGN VALUES FOR A SINGLE LEG OF AN APA PORTAL FRAME USED
ON A RIGID -MSE FOUNDATION FOR WIND OR SEISMIC LOADING `4
Allowable Design (ASD( Values
Minimum Partial Maximum Portal per Frame segment
Width (in.) Height (/) Shear' (Ibf) DeBedion (in.) Load Factor
16 8 850 _ 0.33 3.09
10 625 0.44 2.97
24 8 1,675 0.38 2.88
_ 10 1,125 0.51 3.42
a. Design volues are based on the use of Doug9las-fir w Southam ria ham- ii For other spades of framing, mulbply the above
hear design lue by the spedfic 9 avity pdiustment factor = (1 -10.5 - SG)), where SG = spedfic gmvM of the actual
framing. This odiusTment shall not ba grimhu than 1.0.
It. For construction as shown in Figure 1.
c Values ore for o single portal -home segment done mriml leg and o pportion of The hinder). For mull ple portoldrome
segments, the allowable shear design values are permitted to be multiplied by the number of frame segments.
d. Interpolation of design values for heights between 8 and 10 feet, and for portal widths between 16 and 24 inches, Is
permitted.
e. The allowable shear design value is permitted to be multiplied by a factor of l e for wind design.
f a stay drift is not a design consideration, the tabulated design shear values are permitted b be multiplied by a factor of 1.15.
This factor is perinned to be used wmulotively with the with -design adjustment foan in Foalnote (e) abowa.
Recommended design values for engineered use of the portal frames are provided in Table 1
considering both strength and stiffness. The Table 1 values were developed using the CUREE
cyclic test protocol (ASTM E2126) with a flexible load head to ensure that the code (1130) drift
limit, ductility and safety factor are maintained. For seismic design, APA recommends using the
design coefficients and factors for light -frame (wood) walls sheathed with wood structural panels
rated for shear resistance (Item 15 of Table 12.2-1 of ASCE 7-16). See APA Report T2004-59 for
more details.
Since cyclic testing was conducted with the portal frame attached to a rigid test frame using
embedded strap -type hold downs, design values provided in Table 1 of this document should
be limited to portal frames constructed on similar rigid -base foundations, such as a concrete
foundation, stem wall or slab, and using a similar embedded strap -type hold down.
Form No. 7.10011 • s 7020 PPA- The E,in d Wood Avs-amn • w. w..opowooala, 2
— A Pw f Frame with Hold Downs for Engineered Applications
References
APA. 2004. Confirmation of Seismic Design Coefftcients for the APA Portal Frame. APA Report T2004-59.
Tacoma, WA.
APA. 2012. Effect of Hold -Down Capacity on IRC Bracing Method PFH and IBC Alternate Method. APA
Report T2012L-24. Tacoma, WA.
American Society of Civil Engineers. 2016. Minimum Design Load and Associated Criteria for
Buildings and Other Structures. ASCE 7. Reston, VA.
ASTM International. 2001. Standard Test Methods (or Cyclic (Reversed) Load Test for Shear
Resistance of Vertical Elements of the Lateral Force Resisting Systems for Buildings. ASTM E2126. West
COn5hohocken,PA.
We hnre field rep,eumeeve: in mon, major U.S. ciMs wd In Conode r+ho mn help or—, 9—sr—,—lo.,
APA fiode 6,.d produ[Is. For oddiMo.l epeofYrn6 er,nrooW wood produns, mmmri vs.
APA HEADQUARTERS: 7011 So. 19M Sr. aT... Woe .r,,on 98166.[2531565 6600 • Po.. (2531565 7265
AIA PRODUCT SUPPORT HEV DESK: P531620-7400 • EEmod. belp@opowood.org
DISCLAIMER: a m(o.morbn conbrned Mmn is hosed an APA -The Enp�neered Wood Asmoal�on's cannmm,9
pmproms of laborolory msnrg, product mreoN, and compre rsr.e held a reoce. Nei , APA nor ds members
moke any warronto r, ,rd w i ophod, w Daum¢ or 1e9o1 Ib61iry or mepamib0r, for the vee. oPok-noo of,
oM/or reference ro opinions, f rd,,, , con 1--, m recommendonovs includedin Mir pabhr.roo C-01 put
burl I�nrdmrlon or d-,prof-oo-1 M or, re campf.Mo wen code mnsrmclion, and pedarmorce regwre ,.
Bemuse APA hm no mnMJ mer ay.11te of workmanship .1 6. mrbnw+s ur der which e,,neemd wood prodvcn are
uud, n cannot omepr rerponvblllry (wpradml peHormorce ac despns as admll, connrucred.
T 2020 APA- The Engineered Wod Ass ,00
Form No. M 100H
Rr,os dMa, 2020
APA