Loading...
DIB01 STEP PlanW W W W W W W W W W W W W W W W W W W W W FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMWWWWWWWWWWWWWWWWFMFMFMFMFM FM FM FM FM FM FM FM FM FM FM UGP UGP UGP UGP UGP UGPUG P SS95'59'5 5 58' W WWW 93'349349350 349 35035034935 0 350 FILE NAME:Z:\P\DIB01\CAD\Sheets\DIB01 STEP Plan.dwg DATE/TIME:11/2/2022 8:17:37 AM STEP SYSTEM PLAN THURSTON CO TPN 69270002300 16240 SE PRAIRIE HTS ST YELM, WA 98597 NEW STEP SYSTEM 8 BEDROOM NDTRCB11-02-2022DIB01NDTC112SCALE IN FEET20100VICINITY MAPNTSKEY NOTES1.EXISTING SEPTIC TANK TO BE ABANDONED IN ACCORDANCE WITHDEPARTMENT OF ECOLOGY REQUIREMENTS.2.EXISTING CLEANOUT TO BE REMOVED3.EXISTING BUILDING DRAIN.4.PROPOSED PRELOS 1500 STEP TANK INSTALLED IN ACCORDANCE WITHMANUFACTURER SPECIFICATIONS AND DETAILS 1,2/C25.PROPOSED 4" CLEANOUT (TYP)6.PROPOSED 6 LF OF 4" SCH40 PVC @ 0.02 FT/FT7.PROPOSED FULL DEPTH SAWCUT. REPLACE PAVEMENT PER DETAIL 5/C28.PROPOSED 6 LF OF 4" SCH40 PVC @ 0.02 FT/FT9.PROPOSED CONDUIT FOR POWER AND CONTROL WIRING TO BE SIZED BYELECTRICIAN10.PROPOSED 96 LF OF 1.25" SCH40 PVC OR CL200 FORCEMAIN LINEINSTALLED PER DETAIL 3/C211.PROPOSED CONTROL BOX PER DETAIL 2/C212.DEPTH AND LOCATION OF EXISTING WATER LINE IS UNKNOWN ATCROSSING. ENSURE EXISTING WATER LINE IS 18" ABOVE PROPOSEDFORCEMAIN LINE. LOCATE WATER LINE AT PROPOSED CROSSING PRIOR TOCONSTRUCTION.13.EXISTING WATER LINE. DEPTH AND LOCATION ARE UNKNOWN. LOCATEPRIOR TO START OF CONSTRUCTION.14.APPROXIMATE LOCATION OF EXISTING WATER METER (TYP)15.DEPTH AND LOCATION OF EXISTING WATER LINE IS UNKNOWN ATCROSSING. ENSURE EXISTING WATER LINE IS 18" ABOVE PROPOSEDFORCEMAIN LINE. LOCATE WATER LINE AT PROPOSED CROSSING PRIOR TOCONSTRUCTION.16.EXISTING WATER MAIN (TYP)17.CONNECT TO EXISTING 2" FORCEMAIN PER DETAIL 4/C218.EXISTING 2" FORCEMAIN. MATERIAL IS UNKNOWN.19.PROPOSED SERVICE BOX WITH VALVES PER DETAIL 4/C2#SITE DATAPARCEL #:69270002300SITE ADDRESS: 16240 SE PRAIRIE HTS STYELM, WA 98597PRESIDING JURISDICTION:CITY OF YELM, WA# OF BEDROOMS SERVED:8EXISTING FEATURES ARE APPROXIMATELY AS DEPICTED IN THURSTONCOUNTY GEODATA. ALL EXISTING FEATURES AND TOPOGRAPHY SHOWNSHALL BE VERIFIED PRIOR TO BEGINNING CONSTRUCTION. ANY AND ALLDISCREPANCIES FOUND BETWEEN ACTUAL EXISTING CONDITIONS ANDTHE EXISTING CONDITIONS SHOWN HERE SHALL BE IDENTIFIED TO THEPROJECT ENGINEER PRIOR TO CONTINUANCE OF ANY WORK.EXISTING CONDITIONSEXISTINGSINGLE-FAMILYRESIDENCE(8 BEDROOMS)41235689101112131415161718123456789101112131415ABCDEFGHIJ3 6 0 -8 9 0 -8 9 5 5 | 2 9 9 N M a r k e t B l v d , C h e h a l i s , W A 9 8 5 3 2DESIGNED BY:DRAWN BY:DATE:PROJ. NO:OFREVIEWED BY:Know what's BELOWCall 811 before you dig.NICH O L ASDAVIDAYLORSTAT E OFWASHINGTONREGISTEREDPROFESSIONALENG INEER T461131 1 - 2-2022 197THE WORK ON THIS PROJECT SHALL BE PERFORMED INACCORDANCE WITH CITY OF YELM (CITY) STANDARDS AND THESTANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPALCONSTRUCTION, 2022 WASHINGTON STATE DEPARlMENT OFTRANSPORTATION (WSDOT) (HEREAFTER "STANDARD SPECIFICATIONS")ALSO INCORPORATED INTO THESE CONTRACT DOCUMENTS BYREFERENCE ARE:A. CITY OF YELM DEVELOPMENT GUIDELINES AND PUBLIC WORKSSTANDARDS, CURRENT EDITION.B. THE INTERNATIONAL BUILDING CODE (IBC), CURRENT ADOPTEDEDITION WITH ANY CITY MODIFICATIONS.C. MANUAL ON UNIFORM TRAFFlC CONTROL DEVICES (MUTCD)D. THE INTERNATIONAL FIRE CODE (IFC), CURRENT ADOPTED EDITION.E. CITY OF YELM MUNICIPAL CODEF. NATIONAL ELECTRIC CODE (NEC), CURRENT ADOPTED EDITION.CURRENT EDITlONS OF THESE STANDARDS SHALL BE USED WHICHEXIST ON THE DATE OF CONTRACT ACCEPTANCE.CONTRACTOR SHALL OBTAIN COPIES OF THESE PUBLICATIONS ATCONTRACTOR'S OWN EXPENSE.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR,MATERIALS, TOOLS, EQUIPMENT, TRANSPORTATION, SUPPLIES, ANDINCIDENTALS REQUIRED TO COMPLETE ALL WORK SHOWN ON THESEDRAWINGS AND TO OBTAIN ACCEPTANCE BY THE CITY AND THEPROJECT OWNER.THE INTENT OF THESE DRAWINGS IS TO PRESCRIBE A COMPLETEWORK. OMISSIONS FROM THE DRAWINGS OF DETAILS OF WORK WHICHARE NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS SHALLNOT RELIEVE THE CONTRACTOR FROM PERFORMING THE OMITTEDWORK.ANY PROPOSED ALTERATIONS BY THE CONTRACTOR AFFECTING THEREQUIREMENTS AND INFORMATION IN THESE DRAWINGS SHALL BE INWRITING AND WILL REQUIRE APPROVAL OF THE ENGINEER ANDINSPECTOR.PROJECT SPECIFICATIONSCONTRACTOR SHALL OBTAIN A RIGHT OF WAY PERMIT PRIOR TOCOMMENCING ANY WORK LOCATED IN THE CITY'S RIGHT OF WAY. ALLWORK PERFORMED IN THE CITY'S RIGHT OF WAY SHALL ADHERE TODRAWINGS, STANDARD SPECIFICATIONS, AND REQUIREMENTSOUTLINED IN THE RIGHT OF WAY PERMIT.WORK IN CITY RIGHT OF WAYTHE IRIS GROUP IS REQUIRED BY THE CITY TO PROVIDE RECORDDRAWING CERTIFICATION PRIOR TO FINAL COUNTY ACCEPTANCE. THEIRIS GROUP WILL NOT CERTIFY RECORD DRAWINGS UNLESS THE IRISGROUP HAS INSPECTED SUBGRADES AND ACTUAL INSTALLATION OFALL IMPROVEMENTS DEPICTED HEREIN PRIOR TO BACKFILLING. IT ISTHE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE IRIS GROUPWITH 7 DAY NOTICE PRIOR TO THE REQUIRED INSPECTIONS.CONTRACTOR SHALL MAINTAIN ONE SET OF THE CONTRACT DRAWINGSTHAT SHALL INCLUDE, CLEARLY AND LEGIBLY MARKED, ANYALTERATIONS AND LOCATIONS OF UNDERGROUND UTILITIESENCOUNTERED DURING PROGRESS OF THIS PROJECT, AND ANYALTERATIONS MADE TO THE IMPROVEMENTS BEING INSTALLED. SAIDDRAWING SHALL BE MARKED "AS-BUILT" AND SHALL BE SUBMITTED TOTHE DESIGN ENGINEER UPON COMPLETION.INSPECTIONS AND RECORD DRAWINGSCONTRACTOR SHALL PREPARE AND PROVIDE A TRAFFIC CONTROLPLAN TO THE CITY INSPECTOR FOR REVIEW AND APPROVAL PRIOR TOCONSTRUCTION START. IT IS THE CONTRACTOR'S RESPONSIBILITY TOPROVIDE AND MAINTAIN ALL REQUIRED TRAFFIC CONTROL DURING THECOURSE OF CONSTRUCTION.TRAFFIC CONTROLTHE LOCATION OF EXISTING UTILITIES SHOWN HEREIN AREAPPROXIMATE AND ARE BASED ON INFORMATION PROVIDED BY THESURVEYOR AND FROM CITY RECORDS. THE IRIS GROUP ASSUMES NORESPONSIBILITY FOR THE EXACT LOCATION OF EXISTING UTILITIESSHOWN OR NOT SHOWN HEREIN. CONTRACTOR SHALL VERIFY THEEXACT SIZE, DEPTH, AND LOCATION OF EXISTING UTILITIES AND CALLFOR UNDERGROUND LOCATES AT 811 A MINIMUM OF 48-HOURS PRIORTO CONSTRUCTION START. CONTRACTOR SHALL BE FULLYRESPONSIBLE FOR ANY AND ALL DAMAGES RESULTING FROM FAILURETO LOCATE EXISTING UTILITIES.UTILITIES LOCATE NOTETHE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITYWITH ADJACENT PROPERTY OWNERS. DRIVEWAYS AND UTILITYSERVICES SHALL REMAIN ACCESSIBLE AT ALL TIMES.ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTOREDTO THEIR ORIGINAL PRE-CONSTRUCTION STATE OR BETTER.CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITYFOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTIONOF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS ANDPROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLYAND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THECONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE IRIS GROUPHARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, INCONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OFTHE IRIS GROUP.GENERAL NOTESSITE5' FILE NAME:Z:\P\DIB01\CAD\Sheets\DIB01 STEP Plan.dwg DATE/TIME:11/2/2022 8:17:37 AM DETAILSNDTRCB11-02-2022DIB01NDTC222123456789101112131415ABCDEFGHIJ3 6 0 -8 9 0 -8 9 5 5 | 2 9 9 N M a r k e t B l v d , C h e h a l i s , W A 9 8 5 3 2DESIGNED BY:DRAWN BY:DATE:PROJ. NO:OFREVIEWED BY:Know what's BELOWCall 811 before you dig.NICH O L ASDAVIDAYLORSTAT E OFWASHINGTONREGISTEREDPROFESSIONALENG INEER T461131 1 - 2-2022PRELOS 1500 DETAILNOT TOSCALE1MISCELLANEOUS DETAILSNOT TOSCALE2MISCELLANEOUS DETAILSNOT TOSCALE3SERVICE CONNECTION DETAILNOT TOSCALE4 DETAILNOT TOSCALE51.25"1.25"1.25"1.25"1.25"1.25"1.25"THURSTON CO TPN 69270002300 16240 SE PRAIRIE HTS ST YELM, WA 98597 NEW STEP SYSTEM 8 BEDROOM