2021.0513.ST0055 Permit Issue Pck 10.08.2021CØAAX021
CØABX079
CØUNK
SUN
D
A
N
C
E
A
V
E
S
E
MI
D
D
L
E
S
T
S
ECASCADIAN AVE SER
I
C
HM
O
N
T
C
T
S
E
O
A
K
R
I
D
G
E
C
T
S
E
CAS
C
A
DI
A
N
A
V
E
S
E
GREENLEAF LOOP SE"16416"
"16402"
"16408"
"16414"
510032683 186058267
111026119
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
Sub Order
108124599
N/A
PSE
No
No
No
Yes
Yes
Yes
No
YesDeveloper
"Flagging Required"
"Outages Required"
"Locates Required"THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIGSAP W.O. #186058267FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
POWER GENERAL NOTES
1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this
work sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy.
2.All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three
(3) working days in advance.
3.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work
to get the underground facilities located.
4.All work is to be done in accordance with local municipal and county permit requirements as applicable.
5.Inclement weather conditions may cause delays in construction times and dates.
SCALE: 1:100
SITE PLAN P01
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
W. VILLANUEVA 253-285-6201 10/16/20
W. VILLANUEVA 253-285-6201 10/16/20
N/A N/A N/A
C. ROATE 253-841-6283 10/16/20
N/A CITY OF YELM
ENGR1 COMCAST TK#4430134
REPLACE 1 TRANSMISSION POLE
16416 SUNDANCE AVE SE, YELM, WA 98597
POTELCO
N/A N/A
N/A 186058267
AS NOTED 1/1
THURSTON N/A N/A QSTHLE
T17-R02E-S19 N/A N/A
1702E076 1702E116 1702E076 YEL-27
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
THIS PAGE PERTAINS TO DISTRIBUTION UNDERBUILD
SEE ADDITIONAL PRINT FOR TRANSMISSION NOTES
SITE SPECIFIC NOTES
P01 (559409-147769)
-REPLACE EXIST 75' CL1 POLE W/ NEW 75' CLH2 POLE PER TRANSMISSION W/O# 111026119
-INST SGL ARM UNDERBUILD (6034.1010 TANU315)
-TRANSFER EXIST 15kVA 120/240v XF W/POLE MOUNTED LB C/O FUSED AT 6T (3412100)
-TRANSFER JUMPER
-INST 1Ø TERM OH-UG (6043.1000 TSU1C1) W/LB C/O FUSED AT 40T (3412500)
-INSTALL NEW 2" RISER ON S/O BKTS(6042.1000RIS2CSS) APPROX 50' ( ') UP POLE
-REPULL NEW 1/0 UG PRI APPROX 320'(_______') FROM EXISTING PAD MOUNT XF
-INST EXIST SW #Y1591
-INST SEC FG HH (6050.2000 HH14350) SEE HH NOTES
-TRANSFER EXISTING OVERHEAD TPX
-TOP POLE TO COMMS
UG CIRCUIT MAP: 1702E076
SCALE 1:100
HANDHOLE NOTES
HH01
-INST NEW 13x24 SEC FG HH (6050.2000 HH14350) AT BASE OF P01
-INST 3 POS FARGOS
-INST 1 45' ± (_________) 1/0 UG TPX IN NEW 2" RISER (6042.1000 RIS2CSS)
-INST 1 2" PVC CONDUIT 5' ± (________) TO P01
-RE-ROUTE & RECONNECT EXIST CUSTOMER WIRE
TRENCH DETAIL
Electric Service Cable in Conduit (NTS)
Electric Service Cable in Conduit
Excavated Dirt Pile
Final Grade
24" Min
24" Min
to
36" Max
Cover
12" Typical
(6" Min)
Backfill for Conduit
Free of rocks
larger than 8"
in diameter)
36" MINIMUM COVER
IN RIGHT OF WAY
To Excavated Dirt Pile
3" Schedule 40 Grey PVC
Backfill for In Conduit - The backfill layer shall be soil that is free from construction debris,
glass, sharp rocks, frozen clods, and rocks larger than 8" in diameter.
OH CIRCUIT MAP: 1702E116
SCALE 6" = 1 MILE
JOB SITE
VICINITY MAP
JOB SITE
New pole at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER TRANSFER
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P01
559409-147769
15kVA 120/240v
SIDE VIEW
15"
23-1/4"32-3/4"
2"
Captive L-Bolt
Lock Cover, 10 lbs
24"
Approx
Approx
13"
Customer's
service
conductors
Conductors enter from
beneath and shall be
folded back with handhole
TOP VIEW
5'-0"
4'-0"
HH1: 1Ø SECONDARY HANDHOLE
SCALE: NONE 6050.2000
P01C
A
S
C
A
D
I
A
N
A
V
E
S
E
S
U
N
D
A
N
C
E
A
V
E
S
EMIDDLE ST SE1
9
1
3
19 13
121212121212S
/WC
L
O
S
E
DR9-9S/WCLOSEDR9-9W20-7A
R
O
A
D
W
O
R
K
A
H
E
A
D
W20-1
W20-4
O
N
E
L
A
N
E
R
O
A
D
A
H
E
A
D200'200'200'W20-7AROADWORKAHEADW20-1W20-4ONE LANEROADAHEAD200'200'200'W20-1ROADWORKAHEAD W20-1ROADWORKAHEAD
W20-1ROADWORKAHEADSTOPFLAGG
ER STOPFLAGGE
R
FROMTOTOW AWAY AREAPHONE 888-9999INFRASOURCE LLC 000 0000000NO PARKINGNO-PARKD
E
T
O
U
R
M4-9bDETOURM4-9bHH01Puget Sound EnergyTraffic Control Supervisor:Gregory HarwoodCard No. 012238Card Exp. 09/30/2023gregory.harwood@pse.com(425)424-6425TEMPORARY TRAFFIC CONTROL PLANPSEPUGETSOUNDENERGYJO%18605826716416 Sundance Ave SE, Yelm, WA 985972/9/21KALI-JAMAL.COLLINS@PSE.COM425-424-6425SHEET 1 of 1Notes:1. All signs and spacing to conform to theMUTCD and City of Yelm standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 11' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT80604028" TRAFFIC CONELEGENDTRAFFIC FLOWSIGN LOCATIONFLAGGERSTOPPOLEWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAY