Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
JB0001201856_Prints
© 2023 Microsoft Corporation © 2022 Maxar ©CNES (2022) Distribution Airbus DS © 2022 TomTom ADDRESS: 305 1ST ST S, YELM WA, 98597PROJECT NAME: JB0001201856 - PRINTSDRAWING FILE LOCATION: G:\SHARED DRIVES\BOOKER ENGINEERING\CLIENTS\CANNON\CANNON COMCAST\PRINTS\YELM\JB0001201856_PRINTS\JB0001201856_PRINTS.DWGAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 305 1ST ST S, YELM WA, 98597PROJECT NUMBER: JB0001201856PERMIT NUMBER: ----CLIENT ENGINEER: KYLE CONNCONFIDENTIAL/ PROPRIETARYSDKMKK01/26/23------------------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.------------BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852111SHEET NUMBEROFKnow what's below.Call before you dig.RN O R T HSITE LOCATIONSHEET INDEX1 - COVER SHEET2/3 - GENERAL NOTES 1/24 - LEGEND5/10 - DESIGN VIEW 1/611 - TYPICALSSCOPE OF WORKTIE INTO EXISTING SPLICE CASE NEAR PSE POLE559330-147371. CONTRACTOR TO DELASH EXISTING12CT FIBER AND OVERLASH NEW 48CT FIBER (NE)ALONG 1ST ST N APPROXIMATELY 2661' TOEXISTING SPLICE CASE LOCATED NEAR PSE POLE559494-147557.VICINITY MAPCONTACTSSHEET 5SHEET 6SHEET 7SHEET 8SHEET 9SHEET 10KYLE CONNENGINEERING MANAGERCANNON CONSTRUCTIONKCONN@CANNONCONSTRUCTIONINC.COM360.701.1633SPENCER KARINIEMIOPERATIONS MANAGERBOOKER ENGINEERINGSPENCER@BOOKERENG.COM360.722.2852 GENERAL NOTES1.THE ACTUAL LOCATION OF EXISTING CONDUIT AND CABLES MAY VARY FROM THE LOCATION SHOWN. BOOKER ENGINEERING DISCLAIMS ANY RESPONSIBILITIES FOR DAMAGES INCURREDTO ANY FACILITIES SHOWN OR NOT SHOWN IN THESE PRINTS. PERSONS WORKING IN THE AREA COVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIGSYSTEM TO CONFIRM THE LOCATION OF UNDERGROUND FACILITIES.2.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTHIN THE CITY OF YELM REGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANYAPPLICABLE STANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BY THE CITY OFYELM INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.3.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTORMUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THE CONTRACTOR SHALLVERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTORTO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THE CONTRACTOR SHALL NOTIFY THE CITY OF YELM INSPECTOR ATLEAST 48 HOURS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.5.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF YELM AND ALL UTILITY COMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIESDURING CONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BERESPONSIBLE FOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.6.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANYPERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.8.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE ASITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.9.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE.10.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF YELM, THE CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITHM.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALLTRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH CITY OF YELM.11.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS ORDESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.12.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OFYELM INSPECTOR AT ALL TIMES. THE CITY OF YELM REQUEST A NEW PLAN SET THAT INDICATES THE NEWLY RELOCATED FACILITIES WHEN CONSTRUCTION IS COMPLETED.14.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTEON THE RECORD DRAWINGS.15.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALLBE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.16.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF YELM ENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.17.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT ANDANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE CITY OF YELM.AS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 305 1ST ST S, YELM WA, 98597PROJECT NUMBER: JB0001201856PERMIT NUMBER: ----CLIENT ENGINEER: KYLE CONNCONFIDENTIAL/ PROPRIETARYSDKMKK01/26/23------------------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.------------BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852112SHEET NUMBEROFKnow what's below.Call before you dig.R AS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 305 1ST ST S, YELM WA, 98597PROJECT NUMBER: JB0001201856PERMIT NUMBER: ----CLIENT ENGINEER: KYLE CONNCONFIDENTIAL/ PROPRIETARYSDKMKK01/26/23------------------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.------------BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852113SHEET NUMBEROFKnow what's below.Call before you dig.RLEGENDXX(XXX')N O R T H#F#F#F 170'194'199'SR 507 SEWASHINGTON AVE SE#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #X FOR SITE PHOTOGRAPHS.CONSTRUCTION NOTES1TIE INTO AERIEL SPLICE CASE NEAR PSE POLE559330-147371 (SP-0013).AS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 305 1ST ST S, YELM WA, 98597PROJECT NUMBER: JB0001201856PERMIT NUMBER: ----CLIENT ENGINEER: KYLE CONNCONFIDENTIAL/ PROPRIETARYSDKMKK01/26/23------------------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.------------BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852114SHEET NUMBEROFKnow what's below.Call before you dig.RN O R T HMATCH TO SHEET 5 2FROM SPLICE CASE NEAR PSE POLE 559330-147371(SP-0013)- DELASH EXISTING 12CT FIBER THEN OVERLASHNEW 48CT FIBER A TOTAL OF 2661' (NE) (15-SPANS) TOSPLICE CASE NEAR PSE POLE 559494-147557 (SP-0055).3ACCESS EXISTING SPLICE CASE FOR MAINTENANCE NEARPSE POLE 559336-147381 (SP-0052).12223202 FIRST ST SPARCEL# 64420400100206 2ND ST SEPARCEL# 64420401000203 SE FIRST STPARCEL# 64420100100106 FIRST STSE PARCEL#644005010001ST & MOSMAN AVE SE PARCEL# 64420300100 (199')230'108'184'1ST ST NSR 507 SESR 510SR 507 SE#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #X FOR SITE PHOTOGRAPHS.CONSTRUCTION NOTESAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 305 1ST ST S, YELM WA, 98597PROJECT NUMBER: JB0001201856PERMIT NUMBER: ----CLIENT ENGINEER: KYLE CONNCONFIDENTIAL/ PROPRIETARYSDKMKK01/26/23------------------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.------------BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852115SHEET NUMBEROFKnow what's below.Call before you dig.RN O R T HMATCH TO SHEET4MATCH TO SHEET 6 2FROM SPLICE CASE NEAR PSE POLE 559330-147371(SP-0013)- DELASH EXISTING 12CT FIBER THEN OVERLASHNEW 48CT FIBER A TOTAL OF 2661' (NE) (15-SPANS) TOSPLICE CASE NEAR PSE POLE 559494-147557 (SP-0055).2222106 FIRST STSE PARCEL#64400501000106 FIRST ST SPARCEL# 64400500100102 YELM AVEPARCEL# 64400600900110 FIRST ST NPARCEL# 64400600100 (184')103'170'74'1ST ST NJEFFERSON AVE NEVAN TRUMP AVE NE#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #X FOR SITE PHOTOGRAPHS.CONSTRUCTION NOTESAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 305 1ST ST S, YELM WA, 98597PROJECT NUMBER: JB0001201856PERMIT NUMBER: ----CLIENT ENGINEER: KYLE CONNCONFIDENTIAL/ PROPRIETARYSDKMKK01/26/23------------------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.------------BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852116SHEET NUMBEROFKnow what's below.Call before you dig.RN O R T HMATCH TO SHEET5MATCH TO SHEET 7 2FROM SPLICE CASE NEAR PSE POLE 559330-147371(SP-0013)- DELASH EXISTING 12CT FIBER THEN OVERLASHNEW 48CT FIBER A TOTAL OF 2661' (NE) (15-SPANS) TOSPLICE CASE NEAR PSE POLE 559494-147557 (SP-0055).22222POLE 559388-147447BYPASSED, OFFEXISTING COMM ROUTE202 FIRST ST NPARCEL# 64421701000103 VAN TRUMP ST NEPARCEL# 64421700100104 VAN TRUMP ST NEPARCEL# 64421600700 (74')218'205'244'1ST ST NSTEVENS AVE NESTEVENS AVE NW#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #X FOR SITE PHOTOGRAPHS.CONSTRUCTION NOTESAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 305 1ST ST S, YELM WA, 98597PROJECT NUMBER: JB0001201856PERMIT NUMBER: ----CLIENT ENGINEER: KYLE CONNCONFIDENTIAL/ PROPRIETARYSDKMKK01/26/23------------------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.------------BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852117SHEET NUMBEROFKnow what's below.Call before you dig.RN O R T HMATCH TO SHEET6MATCH TO SHEET 8 2FROM SPLICE CASE NEAR PSE POLE 559330-147371(SP-0013)- DELASH EXISTING 12CT FIBER THEN OVERLASHNEW 48CT FIBER A TOTAL OF 2661' (NE) (15-SPANS) TOSPLICE CASE NEAR PSE POLE 559494-147557 (SP-0055).2222306 1ST ST NPARCEL#64421600100103 STEVENS AVE NEPARCEL# 64421600200104 STEVENS AVE NEPARCEL# 64421500100 PARCEL# 64421200001455 FIRST ST NPARCEL# 64421800600 (244')367'1ST ST N#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #X FOR SITE PHOTOGRAPHS.CONSTRUCTION NOTESAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 305 1ST ST S, YELM WA, 98597PROJECT NUMBER: JB0001201856PERMIT NUMBER: ----CLIENT ENGINEER: KYLE CONNCONFIDENTIAL/ PROPRIETARYSDKMKK01/26/23------------------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.------------BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852118SHEET NUMBEROFKnow what's below.Call before you dig.RN O R T HMATCH TO SHEET7MATCH TO SHEET 9 2FROM SPLICE CASE NEAR PSE POLE 559330-147371(SP-0013)- DELASH EXISTING 12CT FIBER THEN OVERLASHNEW 48CT FIBER A TOTAL OF 2661' (NE) (15-SPANS) TOSPLICE CASE NEAR PSE POLE 559494-147557 (SP-0055).22PARCEL# 6442120000116135 RAILWAY RD SEPARCEL# 64303601204 (367')93'102'RHO TON RD S E RAILWAY RD SE1ST ST N#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #X FOR SITE PHOTOGRAPHS.CONSTRUCTION NOTESAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 305 1ST ST S, YELM WA, 98597PROJECT NUMBER: JB0001201856PERMIT NUMBER: ----CLIENT ENGINEER: KYLE CONNCONFIDENTIAL/ PROPRIETARYSDKMKK01/26/23------------------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.------------BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.2852119SHEET NUMBEROFKnow what's below.Call before you dig.RN O R T HMATCH TO SHEET82FROM SPLICE CASE NEAR PSE POLE 559330-147371(SP-0013)- DELASH EXISTING 12CT FIBER THEN OVERLASHNEW 48CT FIBER A TOTAL OF 2661' (NE) (15-SPANS) TOSPLICE CASE NEAR PSE POLE 559494-147557 (SP-0055).224ACCESS EXISTING SPLICE CASE FOR MAINTENANCE NEARPSE POLE 559494-147557 (SP-0055).416135 RAILWAY RD SEPARCEL# 64303601204PARCEL# 2271931110016220 RAILWAY RD SEPARCEL# 64300700600 TYPICALSAS-BUILTREVISIONSNO.DATEENGINEERDRAFTERORIGINAL12PROJECT LOCATION: 305 1ST ST S, YELM WA, 98597PROJECT NUMBER: JB0001201856PERMIT NUMBER: ----CLIENT ENGINEER: KYLE CONNCONFIDENTIAL/ PROPRIETARYSDKMKK01/26/23------------------------THE ACTUAL LOCATION OF EXISTING CONDUIT ANDCABLES MAY VARY FROM THE LOCATION SHOWN.BOOKER ENGINEERING DISCLAIMS ANYRESPONSIBILITIES FOR DAMAGES INCURRED TO ANYFACILITIES SHOWN OR NOT SHOWN IN THESEPRINTS. PERSONS WORKING IN THE AREA COVEREDBY THIS DRAWING MUST CONTACT THE STATEWIDECALL-BEFORE-YOU-DIG SYSTEM TO CONFIRM THELOCATION OF UNDERGROUND FACILITIES.------------BOOKER ENGINEERING LLC16778 146TH ST SE #190,MONROE, WA 98272360.722.28521110SHEET NUMBEROFKnow what's below.Call before you dig.R