Loading...
Energy Code WorksheetWindow, Skylight and Door Schedule Project Information Contact Information Width Height Ref. U-factor Qt. Feet Inch Feet Inch Area UA Exempt Swinging Door (24 sq. ft. max.)0.20 1 3 6 8 20.0 4.00 0.0 0.00 Vertical Fenestration (Windows and doors) Component Width Height Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA 0.28 1 2 5 10.0 2.80 0.28 2 2 6 5 25.0 7.00 0.28 1 5 6 30.0 8.40 0.28 1 6 8 48.0 13.44 0.28 1 8 5 40.0 11.20 0.28 1 3 3 6 10.5 2.94 0.28 1 5 5 25.0 7.00 0.28 1 4 2 8.0 2.24 0.28 3 2 2 12.0 3.36 0.28 1 4 4 16.0 4.48 0.28 1 6 4 24.0 6.72 0.28 1 4 4 16.0 4.48 0.28 1 2 3 6.0 1.68 0.28 1 6 4 24.0 6.72 0.28 1 4 4 16.0 4.48 0.28 1 6 4 6 27.0 7.56 0.28 1 4 4 6 18.0 5.04 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 L2M-2853 POWDER ROOM GREAT ROOM GREAT ROOM DINING ROOM DINING ROOM KITCHEN DEN ENTRY ENTRY BEDROOM 2 MASTER BEDROOM MASTER BATH STAIR BEDROOM 4 BEDROOM 3 ATTIC ROOM ATTIC ROOM Exempt Glazed Fenestration (15 sq. ft. max.) 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Vertical Fenestration Area and UA 355.5 99.54 Vertical Fenestration Area Weighted U = UA/Area 0.28 Overhead Glazing (Skylights) Component Width Height Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Overhead Glazing Area and UA 0.0 0.00 Overhead Glazing Area Weighted U = UA/Area 0.00 375.5 103.54Total Sum of Fenestration Area and UA (for heating system sizing calculations) Simple Heating System Size: Washington State Project Information Contact Information Heating System Type: To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (∆T) 53 ∆T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 2,853 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.5 24,251 Glazing and Doors U-Factor X Area = UA Instructions 0.280 356 99.68 Skylights U-Factor X Area = UA Instructions 0.50 --- Insulation Attic U-Factor X Area = UA Instructions 0.026 1,465 38.09 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No selection --- Above Grade Walls (see Figure 1)U-Factor X Area UA Instructions 0.056 2,565 143.64 Floors U-Factor X Area UA Instructions 0.025 1,460 36.50 Below Grade Walls (see Figure 1)U-Factor X Area UA Instructions No selection --- Slab Below Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Slab on Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Location of Ducts Instructions Duct Leakage Coefficient 1.00 Sum of UA 317.91 Envelope Heat Load 16,849 Btu / Hour Sum of UA x ∆T Air Leakage Heat Load 13,881 Btu / Hour Volume x 0.6 x ∆T x 0.018 Building Design Heat Load 30,730 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 30,730 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 38,413 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. L2M‐2853 Above Grade Below Grade Figure 1. All Other Systems Heat Pump (07/01/13)