Loading...
A729B-FireLink-FACP-SpecIntegrated Fire Alarm Control Panel & LTE Cellular Communicator FL-FACP-LTEVS FEATURING: • Lowest Equipment Cost Available for Any Full-Featured Cellular Reporting Fire Alarm Solution • Saves Both Installation Time & Money • Award-Winning All-in-One Design - Cellular Alarm Reporting, Connected by Verizon®, LTE Network for longest cellular lifespan available, 10+ years most extensively deployed cyberprotected LTE network nationwide • Proven NAPCO StarLink Fire® Sole Path Cell High-Performance Dual Diversity Twin Antennae & Signal Boost™ Circuitry for greater range & reliability • Powerful FACP with 8 Conventional Points, preprogrammed • Cloud-based or Software Option for Custom PC-programming: Expandable up to 32 Points, including Conventional, Addressable & Gemini UL Commercial Wireless Devices • Powerful 4A Onboard Power Supply • NFPA & UL Code Compliant + FIRELINK SYSTEM SPECIFICATIONS: • FACP: 8 to 32 Zone Conventional Fire Alarm Control Panel (Firewolf®), 8 conventional fire zones, suitable for 2-wire fire, expandable to 32; 2 programmable NAC circuits, 2A max @ 24V • Annunciator: Menu-driven operation with backlit custom alphanumeric display and functionality for Reset, Acknowledge, Silence (with disable). • Sole Path LTE Cellular Communicator, Commercial Fire (StarLink Fire®) Onboard: Reports on cyberprotected multibillion-dollar cellular LTE (long term evolution) networks, for maximum longevity, security & liability protection, code-compliant, replaces 2 POTs lines • Reports to any Central Station, via dial up or IP, without any special equipment. • Integrated sync and smart operation support on each NAC for System Sensor™ and Wheelock® Notification Devices • Power Supply, 4A @ 24V • Regulated Auxiliary Power Supply – Commercial fire, 12V regulated 2A • 2 Onboard serial ports – one for high-speed local downloading • New! Fully Cloud Programmable, Preprogrammed, or optional Quickloader® Software custom programmable. • Conveniently Preprogrammed – Default Program • Locking Mercantile Enclosure for surface mount* or recess mounting (between the studs) 16”x 14.25” x 5.2” (H x W x D) without cover. Houses up to 16Ah @ 24V battery backup capacity. * Note: For flush mount applications, use external antennae (see ordering info.) • 36-Month Napco Warranty FACP EXPANSION OPTIONS • Expandable with conventional, SLC addressable or commercial wireless devices • Main FACP board supports 1 Addressable Fire SLC (addressable Signaling Line Circuit controllers) • Fire 4-wire bus for annunciators and non-SLC (conventional) devices, including 12V devices • Supports up to 6 additional Red fire annunciators, GEMC-FK1, mounted anywhere on the bus (flashable/updatable firmware) • Addressable SLC Loop Isolator (optional use - for fire applications requiring increased circuit integrity, e.g., meets Class A, Style 7 loop requirements. • SLC Fire Devices supported: Analog smoke detector, analog heat detector, duct detector, pull station, conventional zone module & short circuit isolator FACP INPUTS • Up to 32 Zones/Points from a wide range of initiating devices (see ordering info.) • Addressable SLC Loop – supports up to 1, 32 point loop • Commercial RF Receiver supports GEMC Commercial Wireless Fire devices: Wireless Smoke Detector, Wireless Heat Detector, Wireless contact transmitter (for waterflow, tamper, pull stations, etc.) Model GEMC-WL-WD2 • Conventional 1- to 4-zone EZM Expansion modules on the 4-wire fire bus or SLC loops • Conventional 2-wire or 4-wire smoke detector inputs • SLC Fire Devices supported: analog smoke detector, analog heat detector, duct detector, pull station, conventional zone module & short circuit isolator FACP OUTPUTS • Up to 96 outputs • Two onboard Class B or 1 Class A NAC circuits, 2 amps each, total 2A @ 24V • Onboard Wheelock and System Sensor NAC sync/strobe/horn protocol allows initial silence of audible appliances while maintaining visual notification, without the use of additional modules • Addressable SLC Fire Devices: Supervised relay, unsupervised relay • Fire 4-wire bus devices: 8 zone form C relay (GEMC-RM3008), 8 open collector output (GEMC-OUT8) • Support for Legacy and Existing Notification Appliances – One NAC output configurable for 12V for easy retrofit compatibility • UL Regulated NAC output • Automatic drift compensation for SLC smoke detectors • Programmable obscuration level by smoke detector device • Tri-Mode Smoke Obscuration Report (for addressable detectors) generated remotely or locally (see WI2309LF instructions) • Zone 1 Waterflow • Zone 2 Supervisory (Tamper) • Zone 3 Conventional Fire Zone • Zone 4 Conventional Fire Zone • Zone 5 Conventional Fire Zone • Zone 6 Conventional Fire Zone • Zone 7 Conventional Fire Zone • Zone 8 Supervisory (Cell/IP Communicator Trouble) • Plus Expansion up to 32 Zones/Points Cloud Programming SOLE PATH LTE CELLULAR COMMUNICATOR SPECS • Integrated StarLink Fire Cellular Communicator® - Code-compliant, replaces 2 POTs lines to save thousands of dollars per year over leased landlines. • LTE® (Long Term Evolution) promises the longest cellular lifespan, delivering over 10+ years service for your accounts † • Reports to any Central Station, via dial up or IP, without any special equipment. • Broadest coverage footprint available, Connected by Verizon®. Using LTE CAT1, the most extensively deployed LTE Network in the country, for the best, fastest coast-to-coast StarLink LTE coverage • Communicates critical life and safety alarm reports on cyberprotected multibillion-dollar cellular networks, for maximum security & liability protection • Easy, flexible 24/7 activation & online account management – Ultra-affordable plans are available to meet various codes and requirements, with supervisory check-ins from 200 seconds, to 5-minutes; 1 hour or 6 hours.. • Patented Signal Boost™ signal amplification circuit and high-gain dual diversity, precision LTE twin antennae design & Signal Boost™  circuitry ensure greater range & reliability, maximizing signal acquisition and null-avoidance, receiving signals simultaneously on both antennae • Operating Environment: 0 to 49º C (32-120ºF), up to 93% humidity (non-condensing) Agencies, Compliance UL 864 10th Ed., UL 1635 & NFPA 72 Eds. 2016, 2013, 2010, 2007, CSFM, LAFD, FDNY COA www.napcosecurity.com • call 1.800.645.9445 333 Bayview Ave, Amityville, NY 11701 USA (NASDAQ:NSSC) Product specifications subject to change without notice. FireLink®, StarLink Fire®, Signal Boost, Firewolf®, Gemini® Commercial & Quickloader® are trademarks of Napco. Verizon® and Connected by Verizon, LTE, AT&T®, UL, NFPA and other trademarks, remain intellectual property of their respective companies and are unaffiliated with Napco † LTE longevity claims are those of the cellular carriers.. A729B ©NAPCO, 2020.11 ORDERING INFORMATION FL-FACP-LTEVS (shown below) Firewolf 8 Zone 24V Conventional Commercial Fire Alarm Control Panel with onboard StarLink Fire® Sole Path, Verizon LTE Cellular Alarm Communicator and integral menu-Driven LCD annunciator, w/ 4 Amp, 24V Power Supply. Optionally expandable up to 32 Points /Zones via commercial addressable, wireless or conventional fire devices (2 on board NACs providing up to 4A notification power). Locking, Mercantile Red Enclosure, (surface or flush mount*), removable 16 x 17” door, with 14.25” x 16” base. Houses up to 16Ah battery backup. * Note: For flush mount applications, use external antennae (see SLE-ANTEXT75..., below) FL-FACP32-LTEA As above but with AT&T LTE Network. WI2309LF Installation Manual for FireLink® FACP 32 Series SLE-ANTEXT75 Optional Extended Antenna (new pro-grade conical shape), with 75’ cable. [Versions also available with 50’ cable (SLE-ANTEXT50) or 30’ cable (SLE-ANTEXT30).] Also see new Dual Path models (VZ & ATT) & additional peripherals below FL-FACP-LTEVS Conventional Fire System Peripherals GEMC-FK1 LCD Fire Red Annunciator (Menu-driven operation, functionality for Reset, Acknowledge, Silence (with disable). GEMC-EZM8 8-point Expansion Module FWC-CNV-PULL Conventional Single Action Pull Station, with Hex Reset FWC-CNV-PULLK Conventional Single Action Pull Station, with Key Reset FWC-CNV-PULL2 Conventional Dual Action Pull Station, with Hex Reset FWC-CNV-PULL2K Conventional Dual Action Pull Station, with Key Reset Commercial Wireless Peripherals GEMC-WL-SMK Gemini Commercial Wireless Smoke, Photoelectric (complete). GEMC-WL-HEAT Gemini Commercial Wireless Heat, 135º F GEMC-WL-WD2 Gemini Comml Wireless Input Module converts any UL listed device into a UL wireless device (ex., pull stations or sprinkler supervisories.) GEMC-REVC Gemini Commercial Wireless 255 point RF Receiver (up to 4 per system, max.) GEMC-WL-CO Gemini Wireless Carbon Monoxide Detector Addressable Peripherals GEMC-FW-SLC Addressable SLC Fire Module, supports up to 128 addressable SLC fire devices, below. Up to 2 connect to Panel. FWC-FSLC-SMK Addressable Analog SLC Smoke, photoelectric, head** FWC-FSLC-HEAT Addressable Analog SLC Heat, 135 - 150ºF, head** FWC-FSLC-DUCT Addressable SLC Duct smoke detector, photoelectric (Requires use of GEMC-24VR Voltage Regulator) Inclds 2 onboard relays that follow state of detector. FWC-FSLC-DUCTRA Remote Indicator Plate with LED indicator & key reset. FWC-FSLC-EZM2 Addressable SLC 2-zone conventional expansion module. Uses one address on SLC loop, but yields 2 indep. contact monitoring circuits, for pull stations, water flow and other dry contact alarm initiating devices. FWC-FSLC-EZM1 Addressable SLC 1-input conventional module, similar to usage above. FWC-FSLC-CZM Addressable SLC Conventional Zone module, for monitoring of dry contacts, i.e., pull stations and conv. smokes (Requires use of GEMC-24VR Voltage Regulator) Creates a 24V 2-wire fire zone on the SLC loop, selectable Class A or B zone wiring. FWC-FSLC-RM2 Addressable SLC 2-output module (requires 2 SLC addresses) FWC-FSLC-ISO Addressable SLC Short Circuit Module (Optional: For special applications, meets Class A, Style 7 loop reqts.) FWC-FSLC-SOM1 Addressable SLC Fire supervised output module. Application examples: elevator recall, HVAC shutdown, add’l NAC output w/ power supply (Requires use of GEMC-24VR Voltage Regulator) FWC-FSLC-PULL Addressable SLC Fire Pull Station, standard hex-key reset. FWC-FSLC-PULLK Addressable SLC Fire Pull Station, with key reset. FWC-FSLC-PULL2 Dual action, pull station with hex-key reset. FWC-FSLC-PULL2K Dual action pull station, with key reset. FWC-FSLC-PROG2 Tool for address-programming SLC devices FWC-FSLC-SMK6B ** Smoke/Heat 6" Base, required for FWC-FSLC- SMK and –HEAT devices, above Cloud Programming