Loading...
MM 9 ENGINEERING2018 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 230114 FOR: RUSH RESIDENTIAL PLAN: SUMMIT ENSURE VENTS ARE NOT AT HOLDOWN OR POINT LOAD LOCATIONS (TYP) SITE CRITERIA SIMPSON PRODUCT DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD (V) 551x30' U.N.O. CATEGORY POST PER PLAN 1 OWNER PER OWNER OWNER (3(o) -6D5 Y'x 2Y2' TO 6x6 MIN. RESPONSE S1 RESPONSE Ss POST PER PLAN 25 PSF 97 MPH B D D II <15% NONE NONE 12" 0.4658 1.2868 355 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES t'l IN f=LOOfR f=fR MING/ f=OUNID TION '=LN ENGINEEfRING DO NOT 5Cy4LE(1/4 11 = V) ENSURE VENTS ARE N07 AT HOLDOWN OR POINT LOAD LOCATIONS (TYP) 5LOCKING RESTRAINT AT JOIST END E EACH INTERMEDIATE SUPPORT (SEISMIC ZONE D R502.1) (U4 HOLDOWN 5CHEIDULE SIMPSON PRODUCT FASTENERS 2OoR 24 MODEL NUMBER RX ANCHOR BOLTS NAILS SCREWS CAPACITY# SNOW HDU5 - SIF MEMBER 4340# N/A (14)-6DS y'x 2Y2' TO (2) STUDS 55 5/644 U.N.O. HDU5 - DF MEMBER 56450 � MIN. WDU8 - HF MEMBER 5820# N/A (20)-SD5 Y4'x 2,V2' TO (2) STUDS 56T526 OR 55 1/8'x24 HDU8 - DF MEMBER 1810# POST PER PLAN MIN. URO, HDUII - SIF MEMBER 8030# N/A (30)-SD6 Y4'x2J/2- TO 6x6 MIN. 551x30' U.N.O. WDUll - DF MEMBER 9335# POST PER PLAN 1 HDU14 HF MEMBER 9260# N/A (3(o) -6D5 Y'x 2Y2' TO 6x6 MIN. 551x30' U.N.O. WDU14 - DF MEMBER 144450 POST PER PLAN -12 &0 54 4& 4S'x4&'xl2" WI(6) 104 EACH WAY 5T1-ID14/5T1-ID14RJ - 3500# (2) STUDS U1/ (30)16d N/A N/A M5TC4853 - 39000 PER MFR N/A N/A M5TC6653 - 4.900 PER MFR N/A N/A C514 - 2490# (18) ed EACH END N/A N/A HOLDOWN NOTES: (1) INSTALL ALL SHEAR ANCHORS PER MANUFACTURER INSTRUCTIONS (2) ,ALL METAL CONNECTORS COMING IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE SIMP60N 'Z-MAx', TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED FOR CORROSION PROTECTION. (3) SU56TITUTION WITH NON-61MP50N ,ANCHORS WITH ENGINEER'S APPROVAL. (4) ST1-ID14RJ INSTALLATION AT RIM JOIST LOCATIONS ONLY (RJ=RIM JOIST) LEGEND FOR 1500 PSF 501L 5EARING POINT LOAD KEl' 2OoR 24 MEMBER RX FACTORED �L Z.O 6.0 V� SNOW 3.0 SCUD/COLUMN DE51GNATOR ,y+`0 too fid" EXAMPLES � 30 SHEAIRWALL DESICxNAtOR � o°a ® 0 HOLDOWN/STRAP POST PER PLAN DESIGNATOR sT+D14 �u5 (zzsws c614 DETAIL GALL -OUT POST PER PLAN 1 D1 42 "x42'x12' WK5) 04 EACH WAY SQUASH BLOCKING: (1) STUD(S) FOR POINT LOAD FROM A50VE O SQUASH BLOCK(S) REQUIRED UNDER ALL DBL STUD OR GREATER lUl-IERE INDICATED ON ENGINEERING. (IRC 6023J 5TUD5 SHALL BE CONTINUOUS FROM SOLE PLATE TO TOP PLATE : ;RO LOUJEfR Of= :;RoOf= f=fR t"IING VIT�' L0ED ENGINEEfRING DO NOT eCy4LE(1/4 11 = V) BALLOON FRAME ALL AREAS OPEN 70 ABOVE W/ (2) 2x6 HK 5TUD56 16'O.C. ENGINEERED U51NG BUILDER PROVIDED MFR iR1155 LAYOUT COMPLETED BY THE TRUSS CO JOB NUMBER 55611300F. DO NOT 5WITCH TRUSS MANUFACTURER OR LAYOUT WITHOUT CONSULTING NODCsE DIMENSIONS PROVIDED BY TRUSS MFR, BUILDER TO VERIFY ALL DIMEN510N5 PRIOR TO ORDERING MATERIAL. PROVIDE ALL FINAL SHOP DRAWINGS TO HODCxE ENGINEERING AS SOON AS COMPLETED. IF DESIGNER'S DRAWINGS DIFFER STRUCTURALLY FROM 5HOP5 ADDITIONAL ENGINEERING WILL BE REQUIRED. INSTALL AND BRACE J015T5 AND TRUSSES PER MANUFACTURER FOOTING PAD 5CHEDULE FOR 1500 PSF 501L 5EARING POSITIVE POST TO FOOTING CONNECTION 2OoR 24 20"DIA. OR 24"DIA. x S' ® POST PER PLAN 2.5K CAPACITY OR 4.OK CAPACITY 24 24"x24"x8' W/(2) 04 EACH WAY ® 5.5K CAPACITY POST PER PLAN 30 30'x30"x10" W/(4) 414 EACH WAY ® 6.5K CAPACITY POST PER PLAN 36 36 "x36 "x12" W/(4) *14 EACH WAY ® 12K CAPACITY POST PER PLAN 42 42 "x42'x12' WK5) 04 EACH WAY 16.5K CAPACITY POST PER PLAN -12 &0 54 4& 4S'x4&'xl2" WI(6) 104 EACH WAY 21K CAPACITY 54'x54'xl3' WKI) *4 EACH WAY 2 l CAPACITY 6 0'x6 O'xl4' WK5) 04 EACH WAY 331K CAPAC I TSI' -4 12 xl2 x 16 W101) 04 EACH WAY 41K CAPACITY POST PER PLAN o POSITIVE POST TO FOOTING UJ/ S IMPSON EP5, P5 (2)A35, OR MA5 U.N.O. v• . A Q d. A : d REBAR MAT PER a a ' FOOTING SCHEDULE . c a ° 3" SROM 501 .650E5 4 BOTTOM d. G 00 0 Z 0 W w F -4 milmoll rll- L �_ wI F; � rte+ rU N O 7 N fii •L N a) .0 NO a) a) w � � 70 c) L L L g cc O C c- U 70 7e f6 N N V O V 0 0 cc f6 ~� N a) U L U C� qui+, a) tea)'_0>,�a) 0 0 c N c E c .� 0'� O a >, O OQ cn Q U UU a) (a >, O L N c c -0 -0 N U Q - BUILDING CODE 2018 IBC WIND EXP. 5 91 MPH SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 P5F ENG. P.E. JOIN H. DATE 03,11.2023 REVIEW ZACK C. ENGINEER IAN H. SHEET 1 OF1 OSHEETS PROJECT NUMBER 230114 \FSS/ONALENG� COPYRIGHT cQ2023 I-IODCxE ENGINEERING, INC. DIGITALLY SIGNED Ub4G 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ CERTIFICATE MAY BE REMOVED BY T44E JURISDICTION 2018 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 230114 FOR: RUSH RESIDENTIAL PLAN: SUMMIT (3) 2x6 DF11 STUD: REQUIRED At ALL NDUS NOLDOUAN LOCATIONS. SITE CRITERIA 24" O.C. TRU55/RAFTER5 DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD M 24/16 CATEGORY 15/32', I/2' 32/16 OWNER PER OWNER OWNER RESPONSE S1 RESPONSE Ss 25 PSF 97 MPH B D D II <15% NONE NONE 12" 0.4658 1.2868 355 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES (ADJUST MAN DOOR TO MEET APA MINIMUM WIDTH REQUIREMENT). SHEATH BOTH SIDES v 7 IAIN f=LOOfR LATEfRAL ENGINEEfRINC=i: DO NOT SCALA 0/4 V) SHEATH ALL EXTERIOR WALLS A5 UJI UNLESS NOTED OTHERWISE. N N I(0' MIN 5INGLE PORTAL FR. (ADJUST MAN �w� 70 MEET APA MINIMUM WIDTH REQUIREMENT). SHEATH BOTH SIDES DIMEN510N5 PROVIDED BT RUSH RESIDENTIAL — CONFIRM DIMENSIONS WITH RUSH PRIOR TO POUR f=OUNID AT I ON :='LAN ENC:;lNEEfRlNG_ DO NOT 5CALE (1/4' = 1') 16' MINIMUM PORTAL FRAME WIDTH. ROOD 5HEATHING 5CHEIDULE 24" O.C. TRU55/RAFTER5 SNOW LOAD NOMINAL SPAN RATING (UP TO) THICKNESS �'� 6.0 40 PSF 1/16' S 10 PSF 15/32111/21 32/16 EXtE R9 4x12 D D HEADER HEAR U1 't1 LL 175 PSF 23/321,3/41 48/24 16' MINIMUM PORTAL FRAME WIDTH. ROOD 5HEATHING 5CHEIDULE 24" O.C. TRU55/RAFTER5 SNOW LOAD NOMINAL SPAN RATING (UP TO) THICKNESS �'� 6.0 40 PSF 1/16' 24/16 10 PSF 15/32111/21 32/16 130 PSF 19/32', 5/S' 40/20 175 PSF 23/321,3/41 48/24 ROOD 5HEATHING 5CHEIDULE 1(o" O.C. TRUSS/RAFTERS SNOW LOAD NOMINAL $PAN RATING (UP t0) tNICiWESS 100 P5F 1/16' 24/16 ISD PSF 15/32', I/2' 32/16 LONG DIMENSIONS PERPENDICULAR t0 ROOF JOIST U11tN EDGE SUPPORT. R5032.I.KI) DIMENSIONS PROVIDED BY TRUSS MFR BUILDER TO VERIFY ALL DIMENSIONS PRIOR TO ORDERING MATERIAL. v TION (S; fRA V I T L041D ENGINEEfRINC:;. DO NOT SCALE (I/4" = 1') TRUSS FINAL SHOP DRAWINGS TO BE PROVIDED TO HODGE ENGINEERING FOR REVIEW AS SOON AS COMPLETED. IF FINAL TRUSS DRAWINGS DIFFER FROM DESIGNERS TRUSS DRAWINGS ADDITIONAL ENGINEERING WILL BE REQUIRED. LEGEND POINT LOAD IGEI' MEMBER RX FACTORED DEAD �'� 6.0 L V 2. 0 SNOW 3.0 SCUD/COLUMN � DESICaNAtOR ry+" ,��' EXAMPLES10 o SHEARlUALL DESIGNATOR � va HOLDOUJN/StR4P DESIGNATOR STNDI4 (zx.6ws c514 DETAIL CALL-OUT 1 D1 00 Z 0 W w F -4 milmoll rl� - BUILDING CODE 2018 I5C WIND EXP. 5 91 MPH SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 FF ENG. P.E. JOIN H. DATE 03, .2023 REVIEW ZACK C. ENGINEER IAN H. SHEET z OF1 0SHEETS PROJECT NUMBER 230114 GOPI'RIGNt cQ2023 I-IODCxE ENGINEERING, INC. DIGITALLY SIGNED R U)4G 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ CERTIFICATE MAY BE REMOVED BY T44E JURISDICTION 2018 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 230114 FOR: RUSH RESIDENTIAL PLAN: SUMMIT (3 CAR OPTION) SITE CRITERIA SIMP50N PRODUCT DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD M S51x30' U.N.O. CATEGORY (HF x 0.93) SU11 OWNER PER OWNER OWNER d Is ' O.C. 16 6 RESPONSE S1 RESPONSE Ss 2601365 25 PSF 97 MPH B D D II <15% NONE NONE 12" 0.4658 1.2868 355 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES 70N FRAME ALL :AS OPEN TO AVE W/ (2) 2x6 iTUDS g 16'O.G. 32 D2 D3 D3 UFFEfR f=LOOfR L TEfR L ENGINEEfRING DO NOT 5CALE(1/0 11 =1'J SHEATH ALL EXTERIOR WALLS AS CJLUI UNLESS NOTED OTHERWISE. ADJUST CRAWL SPACE vENTS t0 BE 12' MINIMUM AWAY FROM NOLDOUINS (3RD CAR 0F0 ORD CAR OPT) BALLOON FRAME ALL AREAS OPEN TO ABOVE W/ (2) 2x6 HF'2 STUDS 6 16'O.G. 174IN f=LOOfR LATEfRAL ENGINEEfRING DO NOT 5CY4LEN/all = 1'J SHEATH ALL EXTERIOR WALLS AS w NLESS NOTED OTHERWISE. 3'o.c. NAILING -CONTINUOUS SHEATHING OVER MUD 5ILL TYPICAL ALL EXTERIOR WALL5 f=f;; EE 5TANEDING TU5 Of=TION, DO NOT SCALE CI/8" = 1') 5wi (RI 4x8 DF*2 0 SUI( DO NOT SCALE ll/8" = 1'1 ENGINEERED U51NG BUILDER PROVIDED MFR TRUSS LAYOUT COMPLETED BY THE TRUSS CO JOB NUMBER 55611300. DO NOT SWITCH TRUSS MANUFACTURER OR LAYOUT WITHOUT CONSULTING HODGE DIMENSIONS PROVIDED BY TRUSS MFR BUILDER TO VERIFY ALL DIMENSIONS PRIOR TO ORDERING MATERIAL. TRU55 FASTENER SCHEDULE: A35 m 32' cc OR 5DWC 6 m 1(o' OG. (TYPICAL AT ALL GABLE ENDS) NI -TYPICAL AT ALL TRUSS TO PERPENDICULAR TOP PLATE LOCATIONS (UN.O.) (2)H2.5s -TYPICAL AT ALL MULTIPLE PLY TRUSS TO PERPENDICULAR TOP PLATE LOCATIONS (U.N.O.) LGT4 - DI (L,R) 29 D2 (LXMXR) DENOTES LEFT, MIDDLE RIGHT TRUSS BEARING. REFER TO BUILDER PROVIDED TRUSS MFR PROFILES FOR ADDITIONAL INFORMATION. EXTEND HEADER OVER PORTAL FRAME PER DETAIL 5/DI VAIL SHEATHING TO ALL AMINCs MEMBERS U51NG 8d W/ 3' GRID PATTERN. INSTALL 5IMP5ON L5TA 5TRAF6BACKs1oE oof= � MIN V Ifil' LOAD IN ROWS I(od SINKER la 3110.C. DO NOT 5CY4LEN/4 V) PROVIDE ALL FINAL SHOP DRAWINGS TO HODGE ENGINEERING AS SOON AS COMPLETED. IF DESIGNER'S DRAWINGS DIFFER STRUCTURALLY FROM SHOPS ADDITIONAL ENGINEERING WILL BE REQUIRED. INSTALL AND BRACE JOISTS AND ?RLISSES PER MANUFACTURER 5HEAR WALL NY41LING SCHEDULE 11 ad = 2-1/2' x 0.131' SIMP50N PRODUCT FASTENERS NAIL SIZE 4 STUD 4 2x 50TTOM DBL TOP ANCHOR BOLT CAPACITY(PLF) SHEAR WALL APA RATED SPACE f 5LOCKING s PLATE TO PLATE TO RIM TO CONCRETE SEISMIC / WIND LABEL SHEATHING EDGES ADJOINING RIM BELOW J015T BELOW (DF VALUES) MIN. U.N.O. HDUII - MEMBER 8030 EDGES (30)-5D5 J/4'x2 2- TO 6x6 MIN. S51x30' U.N.O. HDUII - DF MEMBER 93350 (HF x 0.93) SU11 1/16' OSB ONE SIDE ad Is 6' O.C. 2x STUD d Is ' O.C. 16 6 (2)�16d a 16 O.C. 5/6' a 46' O.C. 1/2 tv 36 O.C. 2601365 5THD14/5THD14RJ - 3500* (2) STUDS U1/ (30)16d N/A N/A M5TC4853 - 39000 PER MFR SU12 A 1/1(01055 ONE SIDE 8d 6 4' O.C. 3x STUD (2) 2x STUD 16d a 4' O.C. (2)�16d Is 16 O.C. 5/8' ,s 40' O.C. 112',s 28 O.C. 360 / 532 N/A N/A or SU13 1/1(01065 ONE SIDE ad a 3' O.C. (2) 2x STUD 16d s 4' O.C. (2)�16d Is 16 O.C. 5/8' -9 24' O.C. 1/2 s 11 O.C. 41301685 SU14 1/1(01055 ONE SIDE ad 6 2' O.C. (2) 2x STUD 16d s 4' O.C. LTP4 a 16' O.C.5/8' 21' O.C. 1/2 15 O.C. 64016135 SUS 1/1(01055 50TH 51DE5 ad a 3' O.C. (2) 2x STUD 16d a 4' O.C. LTP4 al 16' O.C.5/8' t,12' O.C. 112',s 8 O.C. 980/ 1310 SHEAR WALL NOTES: (1) INSTALL PANELS VERTICALLY (2) WHERE SHEATHING 15 APPLIED ON BOTH SIDES OF WALL, PANEL EDGE JOINTS ON 2X FRAMING SHALL BE STAGGERED 50 JOINTS ON THE OPPOSITE SIDES ARE NOT LOCATED ON THE SAME 5TUD5. (3) BLOCKING 15 REQUIRED AT ALL PANEL EDGES. (4) PROVIDE SHEAR WALL SHEATHING AND NAILING FOR THE ENTIRE LENGTH OF THE WALLS INDICATED ON THE PLANS. ENDS OF FULL HEIGHT WALLS ARE DESIGNATED BY EXTERIOR OF THE BUILDING, CORRIDORS, WINDOWS, OR DOORWAYS OR AS DESIGNATED ON THE PLANS. SEE PLANS FOR HOLDOUJN REQUIREMENTS. (5) SHEATHING EDGE NAILING 15 REQUIRED AT ALL HOLDOUJN POSTS. (6) INTERMEDIATE FRAMING TO 5E WITH 2X MINIMUM MEMBERS. FIELD NAILING 15 12' O.C. UNLESS NOTED OTHERWISE. (1) BASED ON 0.131' x 1-1/2' LONG NAILS USED TO ATTACH FRAMING CLIPS DIRECTLY TO FRAMING. USE 0.131' x 2-1/2' LONG NAILS WHEN NAILING THROUGH SHEATHING. (8) DBL STUDS MAY BE USED IN LIEU OF 3X MATERIAL (9) WHERE PLATE ATTACHMENTS SPECIFY (2) ROWS OF NAILS, PROVIDE DOUBLE JOIST, RIM OR EQUAL. ATTACH PER DETAILS. (10) ANCHOR BOLTS SHALL BE PROVIDED UJ/ STEEL PLATE WASHERS y' x3' x 3', EMBED ANCHORS A MINIMUM OF 1' INTO THE CONCRETE. (11) PRESSURE TREATED MATERIALS CAN CAUSE EXCESSIVE CORROSION IN THE FASTENERS. PROVIDE HOT -DIPPED GALVANIZED (ELECTRO PLATING NOT PERMITTED) NAILS AND CONNECTOR PLATES (FRAMING ANGLES, ETC.) FOR ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED FRAMING MEMBERS. (12) AS AN OPTION TO FRAMING CLIPS SHEATHING 15 TO EXTEND FROM MUDSILL TO TOP OF DOUBLE TOP PLATE FOR SINGLE STORY, AND FROM MUDSILL TO MIDDLE OF STRUCTURAL RIM FOR TWO (+) STORY STRUCTURES. SEE SHEAR NAILING BUILDING SECTION DETAIL. (13)15/1' PLYWOOD SHEATHING MAY BE USED IN PLACE OF THE Y(o' 055 SHEATHING PROVIDED THAT ALL STUD SPACING 15 16' O.C. MAX. (14) 5U5 5HEARWALL REQUIRES 4-1/2' PLATE WASHER (15) 5HEARWALL DESIGNATED WITH AN ASTERISK ($) MAY BE SHEATHED WITH PERFORMANCE CATEGORY 1/16 SMART PANEL T1 -I1 OR 5/16 HARDIE PANEL (16) SIMP50N MA5AP (STANDARD INSTALLATION) MAY BE SUBSTITUTED FOR ANCHOR BOLT. USE 1/2' A5 SPACING HOLDOWN 5CHEDULE SIMP50N PRODUCT FASTENERS NOMINAL MODEL NUMBER RX ANCHOR BOLTS NAILS SCREWS CAPACITY# SNOW HDU5 - HF MEMBER 43400 N/A (14)-SDS)/4'x 2Y' TO (2) STUDS 55 5/844 U.N.O. HDU5 - DF MEMBER 5645* 40/20 MIN. U� HDUS - HF MEMBER 58200 N/A (20)-SD6 Y'x 2Y' TO (2) STUDS 65T528 OR 551/8'x24 HDUS - DF MEMBER 18100 SPAN RATING MIN. U.N.O. HDUII - MEMBER 8030 N/A (30)-5D5 J/4'x2 2- TO 6x6 MIN. S51x30' U.N.O. HDUII - DF MEMBER 93350 15/32111/21 1 LONG DIMENSIONS PERPENDICULAR t0 ROOF HDU14 - W MEMBER 9260* N/A (3(o) -SDS Y4'x 2V2' TO 6x6 MIN. 551x30' U.N.O. HDU14 - DF MEMBER 14445* 5THD14/5THD14RJ - 3500* (2) STUDS U1/ (30)16d N/A N/A M5TC4853 - 39000 PER MFR N/A N/A M5TC6653 - 44900 PER MFR N/A N/A C514 - 2490* (18) ad EACH END N/A N/A HOLDOUJN NOTE5: (1) INSTALL ALL SHEAR ANCHORS PER MANUFACTURER INSTRUCTIONS (2) ALL METAL CONNECTORS COMING IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE 5IMP50N 'Z -MAX', TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED FOR CORROSION PROTECTION. (3) SU55TITUTION WITH NON-51MPSON ANCHORS WITH ENGINEER'5 APPROVAL. (4) STWD14RJ INSTALLATION AT RIM JOIST LOCATIONS ONLY (RJ =RIM JOIST) (IRC 6023) STUDS SHALL BE CONTINUOUS FROM SOLE PLATE TO TOP PLATE BALLOON FRAME ALL AREAS OPEN TO ABOVE Wl l2J 2x6 NF"2 STUDS im 16'O.G. LEGEND 24" O.C. TfRU551RAFTER6 POINT LOAD IGEI' NOMINAL MEMBER RX FACTORED DEVD Z.O 6.0 40 PSF 1/16' SNOW 3.0 SCUD/COLUMN � DESIGNATOR 130 PSS EXAMPLES 40/20 I15 PSF U� SHEARUJALL DESIGNATOR � 1(0" O.G. TRU55/fRAFTER5 O HOLDOUJN/STRAP SPAN RATING DESIGNATOR STHDI4 THICKNESS I00 PSF t2k;614s C6I4 DETAIL GALL-OUt 15/32111/21 1 LONG DIMENSIONS PERPENDICULAR t0 ROOF D1 f�5032.I.Kl) ROOF SHEATHING SCHEDULE 24" O.C. TfRU551RAFTER6 SNOW LOAD NOMINAL gpAN RATING (UP t0) tNICKNESS 40 PSF 1/16' 24/16 10 PSF 15/32', I/2' 32/16 130 PSS 113/321,5/6, 40/20 I15 PSF 23/32', 3/4' 48/24 ROOF &HEATHING 5CHEIDULE 1(0" O.G. TRU55/fRAFTER5 SNOW LOAD NOMINAL SPAN RATING IUP TO) THICKNESS I00 PSF 1/16' 24/16 I80 PSS 15/32111/21 32/16 LONG DIMENSIONS PERPENDICULAR t0 ROOF JOIST WITH EDGE SUPPORT. f�5032.I.Kl) 000 0 Z 0 0 5:W w L >% 700 __ aoQ vi U rr U N O �' � N fii •L N �N •O O cLU �o LJ.I ��Q�0�o J L L C c 0 U g a ; 2018 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 230114 FOR: RUSH RESIDENTIAL PLAN: SUMMIT ENSURE VENTS ARE NOT AT HOLDOU.N OR POINT LOAD LOCATION5 (TYP) SITE CRITERIA 51MP50N PRODUCT DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD (V) 58160' U.N.O. CATEGORY POST PER PLAN 42 OWNER PER OWNER OWNER (3(o)-SD5 ),41'x 2Y2' TO 6x6 MIN. RESPONSE S1 RESPONSE Ss POST PER PLAN 25 PSF 97 MPH B D D II <15% NONE NONE 12" 0.4658 1.2868 355 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES ELEVATION B HOLDOWN SCHEDULE 51MP50N PRODUCT FASTENERS 2OoR 24 MODEL NUMBER ® ANCHOR BOLTS NAILS SCREWS CAPACITY# OR 4.OK CAPACITY WDU5 - SIF MEMBER 4340# N/A (14)-6DS Y'x 2Y' TO (2) STUDS 58 5/844 U.N.O. HDU5 - DF MEMBER 56450 POST PER PLAN MIN. HDU8 - H! MEMBER 58200 N/A (20)-5D5 V4'x 2/V2' TO (2) STUDS 55TB26 OR 581/8'x24 NDUS - DF MEMBER 18100 POST PER PLAN MIN. UN.O. NDUII - SIF MEMBER 80300 N/A (30)-SD5 y4'x2J/2- TO 6x6 MIN. 58160' U.N.O. WDUII - DF MEMBER 93350 POST PER PLAN 42 NDUI4 - SIF MEMBER 9260# N/A (3(o)-SD5 ),41'x 2Y2' TO 6x6 MIN. 581x30' U.N.O. HDU14 - DF MEMBER 14445# POST PER PLAN -72 6O 54 40 46'x48'x12' WI(6) 04 EACH WAY 5THD14/STHD14RJ - 3500# (2) STUDS UJ/ (30) 16d N/A N/A M5TC4883 - 3900# PER MFR N/A N/A MSTC6683 - 4490# PER MFR N/A N/A C514 - 2490# (18) ed EACH END N/A N/A MAIN f=LOOfR f=fRA IIN / f=OUNIDATION �LAN ENGINEEfRING_ DO NOT &CY4LE(1/4 11 = V) ENSURE VENTS ARE NOT AT HOLDOU7N OR POINT LOAD LOCATIONS (iYP) BLOCKING RE5TRAINT AT JOIST END 8 EACH INTERMEDIATE SUPPORT (SEISMIC ZONE D R502.1) L 0 W E f;;i� �00� � 00f= f=fR MIN VIT:""' LO ID ENGINEEfRING DO NOT 5C;y4LE(1/4 11 = V) rRUCT I ONS =55URE TREATED WOOD SHALL BE SIMPSON D FOR CORRO51ON PROTECTION. =R'S APPROVAL. (RJ=RIM JOIST) PROVIDE ALL FINAL SHOP DRAWINGS TO NODGE ENGINEERING AS SOON AS COMPLETED. IF DESIGNER'S DRAWINGS DIFFER STRUCTURALLY FROM 5HOP5 ADDITIONAL ENGINEERING WILL BE REQUIRED. INSTALL AND BRAGS JOISTS AND TRUSSES PER MANUFACTURER FOOTING PAD SCHEDULE FOR 1500 PSF SOIL SEARING POSITIVE POST TO FOOTING CONNECTION 2OoR 24 20"D 1,4. OR 24"D 1,4. x S" ® POST PER PLAN 2.5K C4PAC I TSI' OR 4.OK CAPACITY 24 24 "x24'x8' W/(2) 04 EACH WAY ® 5.5K CAPACITY POST PER PLAN 30 30'x30"x10' W/(4) 414 EACH WAY ® S.SK CAPACITY POST PER PLAN 36 36'x36 "x12' W/(4) 414 EACH WAY ® 12K CAPACITY POST PER PLAN 42 42'x42'x12" W/(5) 04 EACH WAY 16.5K CAPACITY POST PER PLAN -72 6O 54 40 46'x48'x12' WI(6) 04 EACH WAY 21K CAPACITY 54'x54'x13" UJ/(-) 04 EACH WAY 2 -IK CAPACITY 60'x60'x14' WKS) 04 EACH WAY 331K CAPACITY -4 12 xl2 x 16 U KID 004 EACH WAY 41K CAPACITY POST PER PLAN o POSITIVE POST TO FOOTING UJ/ S IMPSON EPS, PS (2)A35, OR MAA U.N.O. a• . ° Q d. RE5AR MAT PER ' a FOOTING SCHEDULE .. a ° 3' FROM SOILOSIDES 4 BOTTOM d. G ' rll- L h� ao E) wI rte+ Q' N 0 (� fii •L N N O O a) � �7, Q (-D- L � cc O C c=(: ♦♦ O N��_��Y� f6 N N V M -c O V 0 0 f6 ~ O N U L L U C N70 0 �,, N L N 0 >, N ++ 0 O C la' E c tt. N O U (6 —N N v 0cm CF N c Q U U U N>, O NC N LO '� N cn N -0 U Q -0 BUILDING CODE 2018 15C WIND EXP. B 91 MPw SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 F5F ENG. P.E. JOIN N. DATE 03,11.2023 REVIEW ZACK C. ENGINEER IAN N. SHEET 4 OF10SHEETS PROJECT NUMBER 230114 COPYRIGHT Qc 2023 HODCxE ENGINEERING, INC. TWIS D DIGITALLY SIGNED PER UTAG 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ GERTFICATE MAY BE REMOVED BY TIS JURISDICTION 2018 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 230114 FOR: RUSH RESIDENTIAL PLAN: SUMMIT SITE CRITERIA 24" O.C. TRU55/RAFTER5 DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD M 24/16 CATEGORY 15/32', I/2' 32/16 OWNER PER OWNER OWNER RESPONSE S1 RESPONSE Ss 25 PSF 97 MPH B D D II <15% NONE NONE 12" 0.4658 1.2868 355 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES 16' MINII'1UI'1 PORTAL FRAME WIDTH. SHEATH BOTH SIDES EADER R WALLS N N 16' MIN SINCsLE SID__ PORTAL FR4ME. (ADJUST MAN DOOR TO MEET APA MINIMUM WIDTH REQUIREMENT). SHEATH BOTH SIDES 3fR[:) C fR ELEV TION 11511 r1741N f=LOOfR LATEfRAL ENGINEEfRINC=i: DO NOT SCALA 0/4 V) SHEATH ALL EXTERIOR WALLS A5 UJI UNLESS NOTED OTHERWISE. DIMENSIONS PROVIDED BY RUSH RESIDENTIAL - CONFIRM DIMENSIONS WITH RUSH PRIOR TO POUR 3fR[:) C fR ELEV TION 11511 f=OUNIDATION :='LAN ENC:;lNEEfRlNG_ DO NOT 5CALE (1/4' = 1') 0 11511 =3f;; D C f;; ELEV TION Uf=f=EfR f=LOOfR fROOf= f=fR IING C:;fRAVIT"' L041D ENGINEEfRINC:;. DO NOT SCALE (I/4" = 1') ROOD 5HEATHING 5CHEIDULE 24" O.C. TRU55/RAFTER5 SNOW LOAD NOMINAL SPAN RATING (UP TO) THICKNESS �'� 6.0 40 PSF 1/16' EXTEND I I HE 9 4x 12DF1 EfR O 1l E 2/ v 130 PSF 19/32', 5/S' 40/20 175 PSF 23/321,3/41 0 11511 =3f;; D C f;; ELEV TION Uf=f=EfR f=LOOfR fROOf= f=fR IING C:;fRAVIT"' L041D ENGINEEfRINC:;. DO NOT SCALE (I/4" = 1') ROOD 5HEATHING 5CHEIDULE 24" O.C. TRU55/RAFTER5 SNOW LOAD NOMINAL SPAN RATING (UP TO) THICKNESS �'� 6.0 40 PSF 1/16' 24/16 10 PSF 15/32111/21 32/16 130 PSF 19/32', 5/S' 40/20 175 PSF 23/321,3/41 48/24 ROOD 5HEATHING 5CHEIDULE 1(0" O.C. TRUSS/RAFTERS SNOW LOAD NOMINAL $PAN RATING (UP t0) tNICiWESS 100 P5F 1/16' 24/16 ISD PSF 15/32', I/2' 32/16 LONG DIMENSIONS PERPENDICULAR t0 ROOF JOIST U11tN EDGE SUPPORT. R5032.I.KI) TRUSS FINAL SHOP DRAWINGS TO BE PROVIDED TO HODGE ENGINEERING FOR REVIEW AS SOON AS COMPLETED. IF FINAL TRUSS DRAWINGS DIFFER FROM DESIGNERS TRUSS DRAWINGS ADDITIONAL ENGINEERING WILL BE REQUIRED. LEGEND POINT LOAD IGEI' MEMBER RX FACTORED DEAD �'� 6.0 L V 2. 0 SNOW 3.0 SCUD/COLUMN � DESICaNAtOR ry+" ,��' EXAMPLES10 o SHEARlUALL DESIGNATOR � va HOLDOUJN/StR4P DESIGNATOR STNDI4 (zx.6ws c514 DETAIL CALL-OUT 1 D1 00 Z 0 W w F -4 milmoll rl� - BUILDING CODE 2018 I5C WIND EXP. 5 91 MPH SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 FF ENG. P.E. JOIN H. DATE 03, .2023 REVIEW ZACK C. ENGINEER IAN H. SHEET 5 OF1 0SHEETS PROJECT NUMBER 230114 GOPI'RIGNt cQ2023 HODCxE ENGINEERING, INC. THIS DOCUIENT 14AS BEEN DIGITALLY SIGNED PER U)4G 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ CERTIFICATE MAY BE REMOVED BY T44E JURISDICTION 2018 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 230114 FOR: RUSH RESIDENTIAL PLAN: SUMMIT (3 CAR OPTION) SITE CRITERIA SIMPSON PRODUCT DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD M S51x30' U.N.O. CATEGORY (HF x 0.93) SU11 OWNER PER OWNER OWNER d Is ' O.C. 16 6 RESPONSE S1 RESPONSE Ss 2601365 25 PSF 97 MPH B D D II <15% NONE NONE 12" 0.4658 1.2868 355 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES 70N FRAME ALL :AS OPEN TO AVE W/ (2) 2x6 iTUDS g 16'O.G. D3 D2 D3 UFFEfR f=LOOfR L TEfR L ENGINEEfRING DO NOT 5CALE(1/0 1'J SHEATH ALL EXTERIOR WALLS AS 5WINLUNLE56 NOTED OTHERWISE. ADJUST CRAWL SPACE vENTS t0 BE 12' MINIMUM AWAY FROM NOLDOUINS (3RD CAR 0F0 ORD CAR OPT) BALLOON FRAME ALL AREAS OPEN TO ABOVE W/ (2) 2x6 HF'2 STUDS 6 16'O.G. I IN FLOOR L TEfR L ENGINEEfRING DO NOT 5CALEN/all = 1'J SHEATH ALL EXTERIOR WALLS AS wi UNLESS NOTED OTHERWISE. 3'o.c. NAILING -CONTINUOUS SHEATHING OVER MUD 5ILL TYPICAL ALL EXTERIOR WALL5 f=f;; EE 5TANEDING TU5 Of=TION. DO NOT SCALE CI/8"=1') (RI 4x8 DF*2 0 DO NOT SCALE (1/8" = 1') SUI( ENGINEERED USING BUILDER PROVIDED MFR ?BLISS LAYOUT COMPLETED 57 THE TRUSS CO JOB " 556113005. DO NOT 5WITCH TRUSS MANUFACTURER OR LAYOUT WITHOUT CONSULTING NODGE DIMENSIONS PROVIDED BT TRUSS MFR, BUILDER TO VERIFY ALL DIMENSIONS PRIOR TO ORDERING MATERIAL. TRUSS FASTENER SCHEDULE: A35 is 32' cc OR 5DWC (o g 16' OC. (TYPICAL AT ALL GABLE ENDS) NI - TYPICAL AT ALL TRUSS t0 PERPENDICULAR TOP PLATE LOCATIONS (U.N.O.) (2)H2.5s - TYPICAL AT ALL MULTIPLE PLY TRUSS TO PERPENDICULAR TOP PLATE LOCATIONS (U.N.O.) (LXMXR) DENOTES LEFT, MIDDLE RIGHT TRUSS BEARINCs, REFER TO BUILDER PROVIDED TRUSS MFR PROFILES FOR ADDITIONAL INFORMATION, 29 D EXTEND HEADER OVER PORTAL FRAME PER DETAIL 5/DI NAIL SHEATHING TO ALL FRAMING MEMBERS U51NG Sd W/ 3' GRID PATTERN. INSTALL SIMPSON L5TA STRAP g BACKSIDE l2J ROWS I(od 5INKERs 3'O.C. 00f= f=MIN VITI!' LOAD ENGINEEfRINC:p DO NOT 5CY4LEN/4 11 = V) PROVIDE ALL FINAL SHOP DRAWINGS TO HODGE ENGINEERING AS SOON AS COMPLETED. IF DESIGNER'S DRAWINGS DIFFER STRUCTURALLY FROM SHOPS ADDITIONAL ENGINEERING WILL BE REQUIRED. INSTALL AND BRACE JOISTS AND ?RLISSES PER MANUFACTURER �Dl �5 SHEAR WALL NY41LING SCHEDULE Iled = 2-1/2'x 0.131' SIMPSON PRODUCT FASTENERS NAIL SIZE 4 STUD 4 2x 50TTOM DBL TOP ANCHOR BOLT CAPACITY(PLF) SHEAR WALL APA RATED SPACE f 5LOCKING s PLATE TO PLATE TO RIM TO CONCRETE SEISMIC / WIND LABEL SHEATHING EDGES ADJOINING RIM BELOW J015T BELOW (DF VALUES) MIN. U.N.O. HDUII - HF MEMBER 80300 EDGES (30)-$D$ J/4'x2 2- TO 6x6 MIN. S51x30' U.N.O. HDUII - DF MEMBER 933510 (HF x 0.93) SU11 1/16' OSB ONE SIDE ad Is 6' O.C. 2x STUD d Is ' O.C. 16 6 (2)�16d a 16 O.C. 5/6' a 46' O.C. 1/2 tv 36 O.C. 2601365 5THD14/5THD14RJ - 3500* (2) STUDS U1/ (30)16d N/A N/A M5TC4853 - 39000 PER MFR SU12 A 1/1(01055 ONE SIDE 8d 6 4' O.C. 3x STUD (2) 2x STUD 16d a 4' O.C. (2)�16d Is 16 O.C. 5/8' ,s 40' O.C. 112',s 28 O.C. 360 / 532 N/A N/A or SU13 1/1(01065 ONE SIDE ad a 3' O.C. (2) 2x STUD 16d s 4' O.C. (2)�16d Is 16 O.C. 5/8' -9 24' O.C. 1/2 s 11O.C. 41301685 SU14 1/1(01055 ONE SIDE ad 6 2' O.C. (2) 2x STUD 16d s 4' O.C. LTP4 a 16' O.C.5/8' 21' O.C. 1/2 15 O.C. 64016135 SUS 1/1(01055 50TH 51DE5 ad a 3' O.C. (2) 2x STUD 16d a 4' O.C. LTP4 al 16' O.C.5/8' t,12' O.C. 112',s 8 O.C. 980/ 1310 SHEAR WALL NOTES: (1) INSTALL PANELS VERTICALLY (2) WHERE SHEATHING 15 APPLIED ON BOTH SIDES OF WALL, PANEL EDGE JOINTS ON 2X FRAMING SHALL BE STAGGERED 50 JOINTS ON THE OPPOSITE SIDES ARE NOT LOCATED ON THE SAME 5TUD5. (3) BLOCKING 15 REQUIRED AT ALL PANEL EDGES. (4) PROVIDE SHEAR WALL SHEATHING AND NAILING FOR THE ENTIRE LENGTH OF THE WALLS INDICATED ON THE PLANS. ENDS OF FULL HEIGHT WALLS ARE DESIGNATED BY EXTERIOR OF THE BUILDING, CORRIDORS, WINDOWS, OR DOORWAYS OR AS DESIGNATED ON THE PLANS. SEE PLANS FOR HOLDOUJN REQUIREMENTS. (5) SHEATHING EDGE NAILING 15 REQUIRED AT ALL HOLDOUJN POSTS. (6) INTERMEDIATE FRAMING TO 5E WITH 2X MINIMUM MEMBERS. FIELD NAILING 15 12' O.C. UNLESS NOTED OTHERWISE. (1) BASED ON 0.131' x 1-1/2' LONG NAILS USED TO ATTACH FRAMING CLIPS DIRECTLY TO FRAMING. USE 0.131' x 2-1/2' LONG NAILS WHEN NAILING THROUGH SHEATHING. (8) DBL STUDS MAY BE USED IN LIEU OF 3X MATERIAL (9) WHERE PLATE ATTACHMENTS SPECIFY (2) ROUES OF NAILS, PROVIDE DOUBLE JOIST, RIM OR EQUAL. ATTACH PER DETAILS. (10) ANCHOR BOLTS SHALL BE PROVIDED U1/ STEEL PLATE WASHERS y' x3' x 3', EMBED ANCHORS A MINIMUM OF I' INTO THE CONCRETE. (11) PRESSURE TREATED MATERIALS CAN CAUSE EXCESSIVE CORROSION IN THE FASTENERS. PROVIDE HOT -DIPPED GALVANIZED (ELECTRO PLATING NOT PERMITTED) NAILS AND CONNECTOR PLATES (FRAMING ANGLES, ETC.) FOR ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED FRAMING MEMBERS. (12) AS AN OPTION TO FRAMING CLIPS SHEATHING 15 TO EXTEND FROM MUDSILL TO TOP OF DOUBLE TOP PLATE FOR SINGLE STORY, AND FROM MUDSILL TO MIDDLE OF STRUCTURAL RIM FOR TWO (+) STORY STRUCTURES. SEE SHEAR NAILING BUILDING SECTION DETAIL. (13)15/1' PLYWOOD SHEATHING MAY BE USED IN PLACE OF THE Y(o' 055 SHEATHING PROVIDED THAT ALL STUD SPACING 15 16' O.C. MAX. (14) 5U5 $HEARWALL REQUIRES 4-1/2' PLATE WASHER (15) $HEARWALL DESIGNATED WITH AN ASTERISK ($) MAY BE SHEATHED WITH PERFORMANCE CATEGORY 1/16 SMART PANEL T1 -I1 OR 5/16 HARDIE PANEL (16) SIMPSON MASAP (STANDARD INSTALLATION) MAY BE SUBSTITUTED FOR ANCHOR BOLT. USE 1/2' A5 SPACING HOLDOWN 5CHEDULE SIMPSON PRODUCT FASTENERS NOMINAL MODEL NUMBER RX ANCHOR BOLT$ NAILS SCREWS CAPACITY# SNOW HDU5 - HF MEMBER 43400 N/A (14)-SDS)/4'x 2Y' TO (2) STUDS 55 5/844 U.N.O. HDU5 - DF MEMBER 5645* 40/20 MIN. U� HDUS - HF MEMBER 58200 N/A (20)-SD6 Y'x 2Y' TO (2) STUDS $5T528 OR $5 1/8'x24 HDUS - DF MEMBER �8�0# SPAN RATING MIN. U.N.O. HDUII - HF MEMBER 80300 N/A (30)-$D$ J/4'x2 2- TO 6x6 MIN. S51x30' U.N.O. HDUII - DF MEMBER 933510 15/32', I/2' 1 LONG DIMENSIONS PERPENDICULAR t0 ROOF HDU14 - W MEMBER 9260* N/A (3(o) -SDS Y4'x 2V2' TO 6x6 MIN. 551x30' U.N.O. HDU14 - DF MEMBER 14445* 5THD14/5THD14RJ - 3500* (2) STUDS U1/ (30)16d N/A N/A M5TC4853 - 39000 PER MFR N/A N/A M5TC6653 - 44900 PER MFR N/A N/A C514 - 2490* (18) ad EACH END N/A N/A HOLDOUJN NOTE5: (1) INSTALL ALL SHEAR ANCHORS PER MANUFACTURER INSTRUCTIONS (2) ALL METAL CONNECTORS COMING IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE 51MP50N 'Z -MAX', TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED FOR CORROSION PROTECTION. (3) SU55TITUTION WITH NON-51MPSON ANCHOR$ WITH ENGINEER'5 APPROVAL. (4) STWD14RJ INSTALLATION AT RIM JOIST LOCATIONS ONLY (RJ =RIM JOIST) (IRC 602.3) STUDS SHALL BE CONTINUOUS FROM SOLE PLATE TO TOP PLATE BALLOON FRAME ALL AREAS OPEN TO ABOVE W/ (2) 2x6 HF"2 STUDS 0 I6'O.C. LEGEND 24" O.C. TfRU551RAFTER& POINT LOAD IGEI' NOMINAL MEMBER RX FACTORED DEVD Z.O 6.0 40 PSF 1/16' SNOW 3.0 SCUD/COLUMN � DESIGNATOR 130 PSF EXAMPLES 40/20 Ilb PSF U� SHEARUJALL DESIGNATOR ml Swi� 1(0" O.G. TfRU551RAFTER5 O HOLDOUJN/STRAP SPAN RATING DESIGNATOR STHDI4 THICKNESS 100 PSF t2k;614s C6I4 DETAIL CALL -OUT 15/32', I/2' 1 LONG DIMENSIONS PERPENDICULAR t0 ROOF D1 f5032.1.1(I) ROOF 5HEATHING SCHEDULE 24" O.C. TfRU551RAFTER& SNOW LOAD NOMINAL SPAN RATING (UP t0) THICKNESS 40 PSF 1/16' 2/16 l(D PSF 15/32', I/2' 32/16 130 PSF 19/32', 5/8' 40/20 Ilb PSF 23/32', 3/4' 48/24 ROOD 6HEATHING SCHEDULE 1(0" O.G. TfRU551RAFTER5 SNOW LOAD NOMINAL SPAN RATING (UP TO) THICKNESS 100 PSF 1/16' 2/16 ISfd PSF 15/32', I/2' 32/1(o LONG DIMENSIONS PERPENDICULAR t0 ROOF JOIST WITH, EDGE SUPPORT. f5032.1.1(I) 000 0 Z 0 0 5:W w L >% 700 __ ao �f�ii •;Lo�N rrU L� U Q O �N O a) a) Ott 0Lo L L ->ocga n V�V N 5f6 00N f6 ~0O N U L L U C co0ca�>�Ej ,0)NOa(0 C� O N ,Q O C0) 70 t � cNcNaEL1c�NNNg�N0UU � O0a, o a N 70 U Q 7 BUILDING CODE 2018 IBC WIND EXP. 5 91 MPH SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 P5F ENG. P.E. JOIN H. DATE 03,11.2023 REVIEW ZACK C. ENGINEER IAN H. SHEET 6 OF1 0SHEETS PROJECT NUMBER 230114 GOPI'RIGNt cQ2023 HODCxE ENGINEERING, INC. T14_15 DOCUIENT 14AS BEEN DIGITALLY SIGNED PER Ub4G 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ CERTIFICATE MAY BE REMOVED BY T44E JURISDICTION EXTENT OF HEADER WATER HEATER D .0 DOU5LE PORTAL FRAME (TWO BRACED PANELS) � FOR SHEAR MIN. 3"xlli" NET � � FOR A PANEL SPLICE (IF SHEATHING R ROOF EXTENT OF HEADER HEADER REQUIRED. (MAY 5E NEEDED) PANEL EDGES SHALL SHEATHING SCHEDULE. SINGLE PORTAL FRAME (ONE BRACED PANEL) ,� - ,� � WATER HEATER SEISMIC ° ° ° ° ° ° ° °° ° ° ° ° ° ° ° LARGER) 5E BLOCKED, AND OCCUR WITHIN STAGGER SHEETS UJ/ 1/6 ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° FASTEN SHEATHING ING TO HEADER fi� 2 �" 01= MID-HEIGHT. NE IG�IT ONE 1�OUJ 01= STRAPS LOCATED 1/3 ,SWAY � ° o ° � � MIN GAP. EDGE CLIPS zz ° d ° TYPO. SHEATHING TO FRAMING - FROM TANK CAP AND 5A6E. � ° d ° UJ/ Sd COMMON OR G,�LV,4NIzED RECOMMENDED FOR 24/1(o 0 3 NAILING 15 REQUIRED. IF 2x4 ° ° ° SOX NAILS IN 3' GRID PATTERN RATED SHEATHING WITH to LAG BOLT PER SEISMIC z o g 2 0 0 0 II 5LOCKING IS USED, THE 2x� 5 •: MAXIMUM SPAN 2� INCHES AS SHOWN AND 3 O.C. IN ALL W STRAP MFR ,4NC�-IOi� INTO O ° 0 ° MUST 5E NAILED TOGETHER WITH It 2 X STUD PLACES ° ° ° ° ° ° ° ° ° 0 0 0 0 00 FRAM ING ( STUDS, 5L OCK ING, ad NAILS " O.C. ,�T � � (3) lid SINKERS. 2 II 1 0 0 O O O O O 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 370 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D YP. i�,� ,�N (2) CONTINUOUS #� RESER �4T .• 51RD BLOCKING 2 DRYWALL PER PL j2 � o0000000o j j j 000000000 s�IE,�T�-IINC�Si�E,�K 0 0 0 0 0 0 0 ° o .� 0 0 0 0 0 0 0 00 FASTEN TOP PLATE TO HEADER FOOTING. •:: 2 X STUD WALL01 � o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 UJ/ TWO ROWS OF 1�D SINKER #� � �." � OM TO �� : • ••• � � EXTEND UJ,�LL SHEATHING 00 00 00 0o II RE5 I� � � .. W � 3 N,41L5 �T 3 O.C. T'rP. , TO TOP OF DOUBLE TOP � m o0 00 4 4 4 o0 00 �' W 12 O.C. �o VENT FLUTE - ° ° ° (B cKSIDE) (B,�cKSIDE) (B�cKSIDE) ° ° ° ° L5TA18 STRAP (5ACK51DE). USE II PLATE a 00'0��l �11 j s STEM UJ,�LL � I.T ° ° ° ° LONGER SERIES To EXTEND To ' 2 ° ° ° ° ° ° ° ° ° ° 00 REQUIRED S IMPSON H1 EACH TRUSS ® ANCHOR 5, 5E TO WALL � o 0 (0 ( � 0 0 0 0 0 0 0 0 0 0 TOP OF PONY WALL, IF PRESENT. • . OR RAFTER ° ° ° ° 0 ° ° DESIGN VALUES INTERPOLATED . _ � � � . PERPENDICULAR 1 CUL,�R TOP o FROM APA TT-100H TA5LE 1 - _ .. .. .. .. .. PLATE INTERSECTION U.N.O.UO • (4) X :: 0. 0.1 :: :: :: FOR NARROW PORTAL WIDTHS � ® (2) H2.S,� 1=0R MULTI PLir .. .. .. .. .. PLAN VIEW � :: :: :: • . • • • • • • • • • • MIN. (2) 2x4 (,ALL DM) OR (2)2x� • .. .. • • • • .. MFR TRUSSES 2�" O.C. UJ/ • • . . ' • • .. .. S .. S .. S .. �QCM� 2 II • • PLN 8001= SHEATHING NG = Z o N � 1/1� 055 SHEATHING MIN. ~� �' .. .. .. • . NAIL L UJ/ ad O.C. FOR `° `� N ° O E o • i • i i • i • i • • • • II i 4% N � O i ' .. .. .. .. .. W .. .. .. .. .. 5THD 14 (UN.O ON PLAN) ' • ' • PANEL EDGES AND 12 O.C. ' � O N N Y X ,o 0 0 0 0 0 0 !� 0 0 0 0 0 0 0 0 (9) • • • IN FIELD Q•— N C L O O L >, O O 0 0 0 0 0 0 0 0 12 4.0 0 0 0 0 0 0 0 • • • j : .L -R N N ~- S' STEM WALL HEADER EXTENDED OVER °' L ° . i6 O O N U U C — o REQUIRED SHE,�RUJ,4LL • . ' • SHEATH ,ALL GA5LE ENDS 4 _ = o �, � Q � 9 A. 9 4 f e f o o o " O � a • , ... ... x 'gin c >. a v O ° o c v.a d. p. o.o p. o.v z c N m O O a •v D� o O v� 0 0 O t U N L N •. a v o e o e e 1 II •• USING 5UJ1 5HEARWALLN70 —— a. o — o/S ,�NCHORSOLTUJ/IEMBED L9 0 �, ' v - - SECTION f•-t — f�•-t II 1 II • I I p U U � U -0 N N, 0 • • • SCHEDULE Q � � o v' av ay. v 4• �� tp,vo o. oo oo , UJ/ MIN 3x3 x.229 PLATE WASHER _ cc 03:=cor to,L O( C O C N ri0 IBC FIGURE 2308.652 4 D5L 50TTOM PLATE 5ri WATER HEATER 5TRAFFING D1 PORTAL FRAME D1 ROOF &HEATHING D1 ad o 4x4 P05T UNO. GUSSET 6 GIRDER SPLICE. / 1(Od 2x SOLE PLATE TO RIM , 1 •iz P;_ P.T. POSTS 1F LE55 THAN S" FULL DEPTH GUSSET EACHZ�"UJ/lid PER SHE,4RUJ,�LL W a ��31 CUT TOP PL,�TE oR DROP� SCHEDULE �, 12 FROM 501L s IDE (10)104. MIN 4X(o POST o SEAM DO NOT CUT SEAM / S II $ .. $ II 9 ad 'm � o.C. 50TTOM PLATE _ • � 3/� T �G SUSFLOOR ad NAIL j T,� POST CONNECTION: 2 II � to o 2 DoUSLE TOP PLATE 2 LLP,4ND GLUE To Jo I STS. - ® Root= FRAMER PER Root= To 31� FLOOR SHEATHING ING o M 0 a o 21 D GU55ET ONE 51DE ONLY FRAMING DETAIL AN FLOOR TO IM . .. � O.C. � PANEL EDGES ® D L R R • . SIMPSoN ST22 OR 22 c51�• WIDTH OF POST W1 (S)10o1 2 � � 3 10 O.C. FIELD NAILING. � 3 FLOOR JOIST . UJ/(18)104 OR DROP BE,�M UJ/ - - I I ® ROOF SHEATHING PER � -S POST CONNECTION: 5LOCK ALL 5EARING. FACE 2 . Root= SHEATHING 2 RIM To TOP PLATE WITH CONTINUOUS TOP PLATE. - GU55ET 50TH SIDES W100) GRAIN AT RIGHT ANGLES TO . / � STRAP MAY 5E PLACED ON - - SCHEDULE l(od AT S' O.C. (U N.O.) 104 NAILS. �� DEGREE 2X� JOIST. • SIDE OF TOP PLATE � II 2 TOENAIL JOIST TO TOP LATERAL 5RACE WI(4)l(od 5IMPSON EP5, P5, (2)A35s ` — / 1/1� 0.5.5. SHEATHING • � � PLATE EACH SIDE DE (6) l(od NAILS I _ I OR MA5 W12x HF #2 STUDS AT On • � � S 12 POST CONNECTION: . 2 1(0" O.C. (UN.0) W/Sd NAILSad SHEATHING TO STUD � (2) lid NAILS 1�" O.C. CRO55 5RACE WITH 2X4 AS 8 DO NOT CUT INTO 45 , (no -I--I 3/S MINIMUM EDGE PER 5HEARWALL � SHOWN uJ/(5)1�d EACH END. DEGREE SHEAR CONE of 3 � 3 / o jro 5E AM PER PLAN ADD 4X4 5LOCK 5ETWEEN UNDISTURBED 501L DISTANCE SCHEDULE WI(4)1(od EACH SIDE .4 D5L 2X TOP PLATE 4 TOP • 2X CRIPPLES ' � .: � MID -SPAN � STRUCTURAL 1-1/411 RIM PLATE To STUD uJ/(2)4 • 1�d 1�' O.C. • S g PLYWOOD FILLER � � 2 x STUD (AS REQUIRED) ° � 3/4T 4G 5U8 FLOOR 4� 9 HEADER PER PLAN 9 MULTIPLE STUDS FOR ° POINT LOAD FROM A50VE 9 / � FLOOR J015T PER PLAN (2) lid NAILS �o � SQUASH BLOCKS IL DOUBLE 2X TRIMMER STUDS •. FLOOR TO FLOOR REQUIRED UNDER ALL ' INT ,4 MIN. FOR > (o' OPENING UNO. - CONNECTION PER PO LOADS / o S SEPARATE FLOOR TO RIM 50ARD TO FLOOR NO STRAP REQUIRED IF •.• ••' • • •2 �o FLOOR CONNECTION �2 JOI5T WITH (2) l(od CONTINUOUS TO AT •. ' ' / P PLATE DETAIL 11 •' � � 2 • CONTINUOUS FULL HEIGHT 5EAM ANDHEADER 5UPPOIRT D1 = _ �/ S FLOOR TO FLOOR CONN CTION � VERTICAL 058. BREAK 0 5ETWEEN TOP PLATES AND EXTEND DOWN OVER 2x STUD WALL PER PLAN • / MUD5ILL ' / 2 CONCRETE SLAB PER PLAN Ln � FOOTING BLOCK ALL PANEL v • ' < • — EDGES NOT LANDING ON 3)VAPOR BARRIER � 2x MEMBER PER PLAN (D (D FOOTING CORNER / • A TOP/BOTTOM PLATE To j 2x PT W1 ANCHOR 5OLT5 STUDS W1(2) l(od THRU 2 PER 5HEARWALL SCHEDULE a• ' " � NAILS TiP. (3) 1�d THRU � FOOTING CORNER FOOT ING 'T' 2 5TEMWALL CORNER #� HORIZONTAL31 _ 5 II FROM m • 4A •° a s NAI T 4 Z R • .e � � � � L OR 5UJ3, SUJ SUJS1 S TOP OF STEM AND a6 12 O.C. SHEAR WALLS � � w e CA ' �• Ivo ° d II J 2 STEM SHOWN � x 0 r r r ri // //rr/rr/ • r � / / / /� ' 30 M IN IM I UM LAP SPLICE 2x PT MUD SILL WITH � II ° _ _ �\rr\/r\r/\r/\rr\rr\r/ �' a \r/\r/\rr\ #4 VERTICAL CAL DOWELS 6 3( 11 .,\\\\\\ \\\\ �o i• ANCHOR 5OLT5 PER %moi\/i\/i\ri\/i\/i\ I �•' . ri\moi\ter\% j 0 O.C. I COLD JOINT. 41 / \\\\ �� \ �, rr rr rr rr r r \� \ EXTEND TO 3 OF THE VERTICAL RE5AR NOT � SHEAR WALL TABLE � j. .\�\ A II 5HOUJN FOR CLARITY / (MIN OF 2 PER PLATE 4 !\\ S •'' \\rr\\ \\r/\\rr� PERSPECTIVE OVERVIEW WITHIN 12 OF ,4N'r i i\ \�r��,� FOOTING 5ASE. EXTEND II ,�rir �" \\i � 14' MIN. INTO STEMUJ,4LL CORNER) MIN FROM �� • «-- \i\ \\i r--- r\\� \/rTYP (UN.0) �• EDGE a — v a — — . ° .a .•' .� i-1 11= I I=1 I I=1 I I=1 I I=1 I I=1 I I� ,III=I i (2) #� CENTERED IN 2 3(4)SLA5 oN GRADE WHERE-III—ii i I-II I—� I i—III-1 I I E ERED „.. j2 S FOOTING 2 MIN / a a / SPECIFIED PER PLAN °J a d• a � BUILDING II 1 •. D .. • • . . _ • ° ' .. S FOOTING AND ROOF CODE 2 015 IBC STEM WALL CORNER STEM WALL T •, . • DROP JOISTS WHERE , D ' ' • � MIN. FOUNDATION DIMENSION DRAINS IF REQUIRED D SPECIFIED PER PLAN WIND • •• NUM5ER OF FLOORS WIDTH THICKNESS WIDTH v • SUPPORTED 5Y FOOT ING OF FOOT ING OF FOOT ING OF STEM 9 NATIVE UND 15TUR5ED 501L EXP. 5 91 MPH D • . D 4 a v 1 FLOOR 12' ( ° OR STRUCTURAL FILL PER SEISMIC DESIGN a 2 FLOOR 1� 1 (° � II GEOTECH CATEGORY D 3 FLOOR 1511 Q II Q II � a FR05T DEPTH 5'r ROOF SNOW � � JURISDICTION LOAD 25 P5F 12 8 6 IBc T,�BLE is09.� 3 CONCRETE CORNEIR5 D1 P05T TO 5U5FLOCIR GIRDER CONNECTION D1 5HEAR WALL NAILING 4 5UILLDING 5ECTICN- D1 FOUNDATION WITH 5LA5. D1 2x STUD WALL PER PLAN ENG. P.E. FLOOR JOIST OR � JOHN H. LANDING DRIVEWAY APPROACH PER DATE � 2 31� T �G SUSFL ooR (UN.o.) 2 2X4 LEDGER W(2) 10d � 1 1 ; ARCHITECTURAL SHEETS 03.1 1.2023 2 �.' ;. i. 2 FLOOR JOISTS PER PLAN REVIEW O.C. i' ,- j GYPSUM WALL 50ARD 3 (3) 2x12 STRINGERS INSTALLED WIEEd COOLER 2 GARAGE 6LA5 PER PLAN Foo I AN zACK C. FLOOR GIRDER PER PL • II NAILS 6 S" O.C. OR TYPE ENGINEER • . 5-1/2 MINIMUM MATERIAL 6 . Ass- 51W SCREWS Q 1(o' O.C.� FULL DEPTH BLOCKING 1,4N H. DIAGONAL 5ETWEEN R15E � � � 3 . 3 CONTINUOUS RESAR REQUIRED AT ALL 5EARING SHEET AND RUN II o PERSPECTIVE (RECOMMENDED FOR 15C 2308.4.(o 2 1od NAIL 12 o.C. (UNO.) 3 UPPER FLIGHT OF STAIRS :_ SUPPORTED ON 3/4 T 4G 2 o CRACK CONTROL) . ;: .� 2x PT UJ/ ANCHOR 50LT5 1 II �.. PER SHEARWALL SCHEDULE ad NAILED O.0 Sd NAIL 12 O.C. ON ALL \r r\i\i\ri\ri\ri COMPACTED SAND/GRAVEL. N 2 x ,\\r\\r\\r\\/\\/\\r\\r\ d Z II PANEL EDGES 12 O.C. �: FRAMING MEM5ER5 NOT AT D o D ;\\/r\\rr\\rr\\rr\\rr\\rr\\rr #�• HORIZONTAL 3 -511 FROM S MELD PANEL EDGES(UN.0) z TO OFST MAN 12 "O.C. 'cA \\\\\\\\\\\\\\\\\\\\\ i A. P E D CONTINUOUS 5UILDING-�,�/��r!r�rr�rr�r/�rr�/r �� 2X4 THRUST 5LOCK W1104 �r\\r\\r\\r\\ 24' STEM SHOWN 70 F SHEETS ORIENTATION OF CORNER `� r r r r ' o FOOTING PER FOOTING \i .\\ice „ S is � O.C. NAIL TO LANDING : ,,' II 9 STUD M,4'r VARY DETAIL �!�\ 04 VERTICAL DOWELS a6 3� J015T S • r PROJECT NUMBER O.C. IF COLD JOINT. EXTEND •(i)3/4' T4G 5U5FLOOR ad NAIL 6 � O.C. ALL .\\r • i�--- X30114 o. HOLDOUJN PER PLAN TO 3" OF THE FOOTING 2 y FRAMING MEM5ER5 AT 2 ° II S 2X8 LANDING JOISTS II — _ — _ — = 5A5E. EXTEND 1� MIN. PANEL EDGES 4 12 O.C. �—III— I I—III—III—III—I 11=1 I I—I 11-1 I ' INSIDE CORNER 2 ; . -I �� I-I INTO 6TEMWALL (uN.0) 10d Q O.C. RIM TO ON ALL FRAMING MEMBERS / D Q D ' A RO g \ \ 11 0 NOT AT PANEL EDGES .,� r�\,, \ \ \ \ D D � 12 g FR05T DEPTH Sir w 23 j 2 TOP PLATE \/\/\/\/\ // .:.:. JURISDICTION P LSC AT TOP � A3Ss \/ \ \ \ \ • • .. .. .. .. •' . \ \ \ Sd AIL �' O C (LL (2) CENTERED IN FOOTING O.C. / _ I is 50TTOM ,�\/\/ . MIN. FOUNDATION ON DIMENSION ><j PANEL EDGE5XUN.0) \\ \\ NUM5ER OF FLOORS WIDTH THICKNESS WIDTH ([D NOTCH STRINGER TO REST SECTION i / SUPPORTED 5Y FOOTING OF FOOTING OF FOOTING OF STEM FOOTING AND ROOF 3 7 8 8 6 a 1 n n FG / �F' STRINGERS SPANNING OVER ON LEDGER D o s T E 1 FLOOR 12 DRAINS IF REQUIRED (o STEPS MUST 5E SUPPORTED , II II 2X TREADS WI(3) 10d 2 FLOOR 1S (0 (0 NATIVE UND I5TUR5ED SOIL NAS W14X(o 5E AM ON 4X4 POSTS, 12 5 . . v II II II 12 5 POST TO 18" CONCRETE FOOTING EACH STRINGER 3 FLOOR 18 S S OR STRUCTURAL FILL PER �o OUTSIDE CORNER DETAIL GEOTECH COPYRIGHT c 2023 OR STUDUJALL O rl3 7 / 15C TA5LE 1009.1 4 COPYRIGHT ENGINEERING, INC. t�IIS DOCUI*-NT BIAS BEEN DIGITALLY SIGNED PER 5TAIR LANDING CONNECTION D1 IN61LDE/OUT61LDE CORNEIR D1 CONT INI�Ol�S 5TRIF FOOTING AT GARAGE ENTRE D1 FOUNDATION WITH FLOOR J O 15T5 D1 WAC WICA E M wlt�I a GLOBAL SIGN 4E JURISDICTION ON CERtIFICAtE MAY BE REMOVED BY tNE JURISDICtION 26) 22) 18) 14) 1 3/4' �ruuoo 1 FACE OF FOOTING 5U�1=BOOR 51TE PLAN, STRUCTURE LOCATION, GEOTECHNICAL REPORT 1 (FLOOR J015T PER PLAN AND 51 TE WORK ARE THE RE SPoN51 1 L I TY 01= THE U I L D E R 2 TOP OF SLOPE z 2 SMEAR WALL NAILING PER AND CIVIL/GEOTECHNICAL ENGINEER.. 0 PLAN D I APHR4GM OPENING Mn 3 H/3 5UT NEED NOT > (I FLUSH DOU5LE 2x J015TBLOCKING UJ/ 3� PER PLAN UNLESS A GEOTECHNICAL REPORT 15 PROVIDED TO EXCEED 40' MAX W 1 DC OR MFR DOU5LE JOIST HODGE ENGINEERING THE SEARING SOILS ARE ASSUMED 0 • � � 1= • WITH WE5 STIFFENERS Ole' 1� TO 5E 1500 P5F OR 2000 P5F. WHEN PROVIDED FOLLOW � TOE 01= SLOPE C514 STRAP ALL DIRECTION OF THE GEOTECHNICAL REPORT. ORT. • ° • SEAM PER PLAN Np S . • F=LOOR JOIST PER PLAN H/2 5UT NEED NOT • SHEATHING PER PLAN • 2 EXCEED 15' MAX w . • STUD/POST PER 5HEAR a DACE OF STRUCTURE o 1 WALL SCHEDULE 2 pill 5EAM/D5L J015T PER PLAN • �o M5TC4053 (WHEN AROUND OPENING (TYPICAL SPECIF=IED ON PLAN) 4 PLACES) CU N.0. ON PLAN) Z ' • 3 (2)C514 OPTION �o BLOCKING FOR STRAP (01 ' , C36' MIN LENGTH, WRAP • • AROUND 5E AM / L 70 g C� �Nam:3 ) •LO O w18' MIN TO STUD WALL ��CO� O�� (01CC514 OPTION a cLU +ULUNor f6 a) N V O V 0 0 9 NAIL SHEATHING TO 5E AM. f6 ~� N a) U L L U C (aES DO NOT BREAK ��0 0 cO,N�Lc(n f� f� t N O U N '� N-0 N 2 CL SHEATHING 0 0 w 0c) CC aE �c0) -aa) `a) Q U U C U 70 aa) j, O NC LO '� a) r26-' r22 18 15C FIG 1808.1.1 rl 4 0 5HEAR WALL AT 5EAM D2 LARGE DIAPHRAGM OPENING D2 D2 FOUNDATION CLEARANCE FROM 6LOFE5 D2 s .r a� a2 j C2) 2x4 LAMINATIONS UJ/ (1� $N 1 END LENGTH = 19' $ � � � 1 2x F=LOOR JOIST OR MF=R = 1 C8) l(od NAILS STAGGERED w _ r N ROW OF STAGGERED 10d o � .� J0I5T. SPACING 4 51ZE PER _ �, AT EACH 51DE OF TOP , ch � � PLAN N N COMMON WIRE NAILS a6 12 oc SIN ,� PLATE 5PLICE. 1 • ° '�� �O 1 2 PROVIDE MINIMUM 1-5/8 Nliallill 2 (3) ad TOE NAILS EACH ° = rj� s� N 2 i 2� 2 X� LAMINATIONS N,4T IONS �/ i 2� � % •• .° END END D 15T,4NCE - - _ 2 c 2 (3) 1(od NAILS STAGGERED •• . N�T�, E D • SIDE EVER' 1� ON CENTER = 20 N ROW 0 STAGGERED 10d •. •° LE CUT Do LENGTH • - - - ctl �� AT EACH SIDE OF 50TTOM • CUT • _ °CCI COMMON WIRE NAIL 5 a6 �O OC PLATE SPLICE. ,. •. LENCITI1.4 00 LENC�T�..I (18) ad N,41L5 IN EACH END • N • 3 2x 5LOCKING CENTERED ONGo EACH SIDE - •. OU TO PLATE. F=U ° ° � ' � 3 (2) l(od NAILS 6 16" oc INTO � • D SLE PPL E LL 2DEPTH STUDS 1 • - ' (3) 2x4 LAMINATIONS UJ/ C1) • 1 � 2-1/2 � 1 � CLEAR -� 3 - , n ROW OF STAGGERED 30d SPAN CLEAR 1N � SIMPSON 36" C514 MAY5E '' SPAN SIMPSON A35 REQUIRED ° COMMON WIRE NAILS 6 16 O � F=0 SUJ2 � SUJ3 SHEAR = EACH SIDE .• USED IN LIEU OF NAILING ,45 � R E R ° • WALLIS. (2) SIMPSON ,435 AT 1' 1 IND ICATEDfNOT SHOWN FOR � 5W4 4 5W5 SMEAR U1ALL500 (3) 2x(o LAMINATIONS UJ/ (2) CLARITY) END e -'� �Q e END (STAGGER AT E,4C�-I SIDE _ ROWS OF STAGGERED 30d °: ENC�T�I LEN�TW - 2 1/2 COMMON WIRE NAILS S'oc °• OF 5LOCKING) 1-1/2 � 2 .. EACH SIDE ° ° • . . INTERIOR SMEAR WALL ° 1-1/2" 3 3 1 NAILING 4 SHEATHING PER 1 NOTE: PLATE SPLICE SECTION VIEW OVERALL PERSPECTIVE PLAN.10 APPLIES WHEN NO OTHER ' 2 C51� 5 C514 5PLICE 15 INDICATED. 3 2 7 MR WS 5.3.3 ROW SC � r23' ri 9 rl 5 INTERIOR STO PERPENDICULAR J015T5 A50VE D2 NAILING 5CHEDULE FOR 5UILT-UP COLUMN D2 PLATE 5FLICE D2 51Mf='50N C514 5TIRAF DETAIL D2 � W 1 1 � 1 MSR GABLE END TRUSS WALL FRAMING I\ 2 1 a EXTEND STRAP ON PON' Ln 2 DOU5LE TOP PLATE WALL TO F=LOOR A50VE V 3/4 T 4G F=LOOR . 1 UJIT�I ,4N M5Tc54. 1 1/2" MIN F=ROM coRNER �4 (U X1.0.ON PLANS . - CENTER STRAP ON m - CONTINUOUS VERT I CAL 3 2 sd 6 O.c. J 015T5 AS SHOWN ° • S�IEAT�IING OVER GA5LE # Q • Q •• ° ° /� � 1 � � REAR. M,4� �E T (0 F=RAMING 3 UJNERE F=OOTING SECTION ° ° (0• TJ I PARALLEL OR TJ I FOUNDATION R OR 5LOCKING 1/4'x(o" 5D5 SCREW AT 16" RE v THROUGH a a . ° ° n P05T TENSION4A O O.0 TOP PLATE TO TRUSS PROVIDE C51(o EACH C)O °00 ° (4)� LLI ad 6 4" O.C. STAGGER 50TTOM COR51DE OF SPLICE U/8 -1d ° ° MIN RE5AR LENGTH °o 2 SIDES. NAIL TH OUH TOP COMMON NAILS o O ° ° z OF FLANGE. DO NOT �m Jw 1 O °TO TOENAIL T U55 TO TOP O ° ° ° � NOTE: �oLDouNS AT (a Ln TJI TYPICAL LADDER 5LOCKING PLAT WITH C1) ad AT 1� O °° CORNER ARE SPACED SHOWN UJ/ TJI 4 2x (3) 1(od NAILS ON CENTER aa � C2) 2X PLATE O O � � Q a a O O 1/2 FROM EDGE. 2 -• N Q OO • �p WGA10 OR A35 AT 32 O.C. � . - 2X� F=LAT � 1� O.C. '.' . a • . . ' a � �IOLDOUJN PER PLAN O O �o 4 S 0 •• - 2 1 ALTERNATIVE TO NOTE 4 a . . . 2 0 • • . - SDS SCREWS� � a a � . � � � CLEAR SPAN 11MAXIMUM. (3) ad NAILS EACH END � � PONY WALL SHEATHING 4 O - •= • • � � FOR TYPE RJ HOLDOWN • SMEAR NAILING TO MATCH— g 9 NOTES qp 0�� FOR NON RJ HOLDOWN5 . - a WALL A50VE 5CREW6 U=WARiS=LOOe JOISTS OeSOLID '. .. W •..•'.•' •• 2 BUILDING • S THROUGH TOP PLATES INTO (o' MAXIMUM PONY WALL . •• � • ° , 5LOCKING � a � :- :. � COMPRE5510N BLOCKING CENTER O 0TTOM T U55 a • . • •, , CODE 201a 15C �E ER � R .. a " 9 HDU HOLDOWN • . (q'),435 � 1 � O.C. OPTION o a o CHORD. • ' a . � • . � • • 9 •' � . A. WIND o ° d 4 .r • d (WHEN SPECIF=IED) � (2) ad NAILS a6 S' O.C. OR e a .. � 9� MPS lid � 1�" O.C. -5RACE TRUSSES PER 5051. f o o a 12' �1 STUD PACK OR POST PER SEISMIC DESIGN N 1 CONSULT TRU55 MANUF=ACTURER • : PLAN 1 5U ILDER TO DETERMINE I I s SMrpson Strong—Tk . _ - CATEGORY D 2 FOR 5RACING REQUIREMENTS. �� a STAID ST�IDRJ IF STAID OR STHD/RJ 15 DIMENSIONAL TYPICAL APPROPRIATE, ROOF SNOW D IMEN510N,4L UJ/ SIMPSON A35 28 r24 2016 LOAD 25 P5F= INTERIOR 5WALL TO J015T ACONNECTION- D2 GA5LE END TO 5HEAR WALL ATTACHMENT D2 5TEF FOOTING 4 PONS' WALL FRAMING D2 5IMP50N 5 D2 ENG. P.E. j JOIN H,. FASTENER PER PLAN DATE D03,11.2023 STUD TO MATCH GIRDER PLS' (U.N.O OOTINC SIzE ,4ND j MANUFACTURED ROOF- REVIEW ° O \i � ° ON ENGINEERING SWEETS) . i\\ REBAIR SCHEDULETRU55 WITH ITH ENERGY PEEL ZACK C. o . o° D o °o ° ° °° ®o ° 00 °° o° 00 SIMPSON LGT2 SIMPSON MGT UJ/ WDU • 00 • 0 ° 0 ALLOWA5LE UPL IF=TS FASTENERS HF/5PL 5D WC SCREW 485 Hi 425 H2BA 535 HIDA 101 HIDA -2 930 LGT2 (2)FLY 1620 LGT3-5D52.5 (3)PLY 2505 LGT4-5[)53 (4)FLY 2920 MCAT (2 )PLS' 3300 (1)VGTR/L (2 )PLY 1(000 ( 2 )VGTR/L (2)PLY 3 990 ( 1 )VGT (2)FLY 3555 (2)VGT (2 )PLY 5110 (2)V (3)PLY 6400 HGT-2 (2 )PLS' 6485 HGT-3 (3/)PLY 9035 C - Y 9250 � *VALUES BASED ON 81MCN STRONG TIE PA57Q�U(IF R Will- �J Iv PRESENT) �`' o,�. F� l STEV l I I Y sc+EnuLe emwE2 TO roLLau ALL rtiaNLIFaciuRER 2 FSS/ONALENG REaurs FOR FASTENER rtrsTau,atiaa. SIMPSON VGt DOUBLE INSTALLATION SIMPSON VGtR/L COPYRIGHT cQ2023 W1 (2) HDua. W1 HDua. 2g 25 tRuss sEctioN 21 inHODGE ENGINE�RINCx INC. a TWIS DOCU*W �IAS MMq DIGIT&I SIGNED MR TRU65 Uf=L IFT CONNECTORS D2 WIDENED FOOTING (OPTION) D2 fi�,41S�p ���L TO 5��1�R UJ�4LL CONNECTION D2 D2 ��,-���,W'T�A,��$ CERTIFICATE. ,� PER PLAN O (IF PRESENT) 3 ENGINEER IAN H. 2 3 SHEAR WALL NAILING PER O O O POR STUDS PLAN SHEET PER PLAN O 1/16' OSB OR SMART SIDE PANEL BLOCKING lU/ ad a O SOOT INCA PAD CAN (Oil oc INTO DOUBLE TOP 4 TOP CHORD BIRD � BE PLACED 5ELOW PLATE THE CONT INUOU5 PERSPECTIVE INTERIOR PERSPECTIVE EXTERIOR BLOCK ��� aOF10SHEETS FOOT ING, IF ROOF SNEAtNSHEATHINGP�PERPLAN � PROJECT NUMBER W1 ad � 6' oc INTO BIRD PREFERRED o-� BLOCK BLOCKINCx. � 230114 'fG�P�� O N H1 TYPICAL X OW ARS �` � SLBOTTOM fl- At ALL TRU � LL � OF W 3 CI -LORD TO DOUBLE TOP �c O PLAtE INTERSECTIONS �P SOFfIt MATERIAL � p 378 � *VALUES BASED ON 81MCN STRONG TIE PA57Q�U(IF R Will- �J Iv PRESENT) �`' o,�. F� l STEV l I I Y sc+EnuLe emwE2 TO roLLau ALL rtiaNLIFaciuRER 2 FSS/ONALENG REaurs FOR FASTENER rtrsTau,atiaa. SIMPSON VGt DOUBLE INSTALLATION SIMPSON VGtR/L COPYRIGHT cQ2023 W1 (2) HDua. W1 HDua. 2g 25 tRuss sEctioN 21 inHODGE ENGINE�RINCx INC. a TWIS DOCU*W �IAS MMq DIGIT&I SIGNED MR TRU65 Uf=L IFT CONNECTORS D2 WIDENED FOOTING (OPTION) D2 fi�,41S�p ���L TO 5��1�R UJ�4LL CONNECTION D2 D2 ��,-���,W'T�A,��$ CERTIFICATE. ,� 42 / 138 Id 42 D3 43, D3 m =X I MV MAL N 4 JVI? I LSA i;V NOT REQUIRED O SIMPSON DTT2Z DECK T HANGERS UJ/ 1/2' NDC ALL O THREADED RODS O FLOOR JOIST PER PLAN. O UlEB STIFFENERS REQUIRED 04 6 12' OC FOR MFR SLR JST $ (4) APPLICATION O DECK JOISTS PER PLAN r O FLOOR SHEATHING NAILING 41_g11 PARALLEL JOIST: 6' cc. 4' PERPENDICULAR J0I6T:3'oc O DOUBLE BLOCKING REQUIRED FOR PERPENDICULAR INSTALLATION UJ/ 1/4'x2 -I/2•• SDS SCREWS O TOE NAIL BLOCKING t0 PLATE UJ/ (2) IC d NAILS PERPENDICULAR FLOOR JOIST IDECK5 UNDER 30" A50VE GRADE LATERAL DECK CONNECTION / MINIMUM OF (4) DTT1Z OR 30 EXAMPLE RESIDENCE O SHEATH UNDER OvERFRAMINCx 2x4 RAFTERS m 24" cc SUPPORTED AT (o' cc MAX UJ/ 2 x4s ON TRU55 CHORD. 2x(o RAFTERS 6 24" cc SUPPORTED AT 8' cc MAX UJ/ 2 x(o's ON TRU55 CHORD. (2) 2x& VALLEY 5OARD5 U.N.O. NAILED TO EACH TRU55 UJ/ (3) 1(od NAILS. 2 x(o RIDGE 5OARD U.N.O. ROOF SHEATHING PER PLAN VENT I L AT ION ACCE 55 PEP 5U ILDER. 22-1/2 "x48" MAX DIMENSION. O 38 34 30 D3 D3OVERFRAMING D3 (D 51MP5ON DTT1Z DECK TENSION TIE 6) 09 x 1-1/2" 5 I MP50N SD 5CREUJ5 (SWOUJN ) OR (8) 0.148' x 1-1/2' NAILS 3 DECK JOISTS PER PLAN 3/6" SIMPSON NDC LAG SCREW WITH NDC WA6WER OR 5DUJN TIM5ER-HEX NDC SCREW (SHOWN) INTO TOP PLATE, STUDS, OR HEADER O FLOOR JOIST PER PLAN O FLASHING BY OTHERS - 2 1 SHOWN FOR REFERENCE 3" MIN. TONLY PENETRATIONC�D TION L�DC�ER A7tACNMENt PER PLAN OPTION OF (l) DTT2Z IN LIEU OF (2) DTtIZ NOS REQUIRED FOR DECK5 UNDER 30" AFDOVE GRADE 39 C -C 2021 (WOOD CONSTRUCTION CO�JECTORS), PAGE 295 //" 1 LATERAL DECK CONNECTION - LDTTIZ D3 0 * SES SNEARIUALL TABU FOR ADDITIONAL NAILING DECK LEDGER CONNECTION $ O 2X SOLS PLAN t0 RIM T LU/16d a 6' O.C. U.N.O. x O 3/4 TSG TO RIM: D ad 6 6" O.C. O 2X OR MFR FLOOR JOIST 04 6 12' OC RIM 70 MUD SILL lU/16d $ (4) Aa 4' O.C. U.N.O. O ANCHOR BOLT PER PLAN $ O SHEATNINCx TO STUD 41_g11 SEE SWEAR UJ,4LL 4' SCHEDULE O (3) SDS 1/4'x3 -I/2' SCREWS *5 -9 9' OC STAGGERED a 16' O.C. 14' INTO STRUCTURAL 2x O OR 1-3/4' RIM OS CONCRETE FOUNDATION O DECK JOIStS PER PLAN 3/4' T4 Cx FLOORING O / 4U LIIC' O EXTEND SNEAtNING t0 31 LOWER TRUSS BOttOM � \ CNOi2D � OZ ATTACH ALL ADJACENT � / � TRUSS CHORpS WITHSECtION lU/ 3X STUD (3)1/411x3" SDS SCREWS O BLOCKING BEWIND SNEATNING CUT FOR FLASHING 36 L^ C .1 C C L z C C u C 0- C C u EXAMPLE RESIDENCE EXTEND 5HEATHING TO TRUSS BOTTOM CHORD w j/- UNRESTRAINED RETAINING WALL SCHEDULE 35 D3 H UJ T VERTICAL 5 K D 0 8' 9' 04 6 12' OC 40' 3' 4' (O'1'-8' 8 12' 45 9 10' OC 41_g11 11 4' all, -10' 8' 12' *5 -9 9' OC (o'-3' 14' 1-3/4' 8' WALL VERTICAL AT 1-3/4" FROM FACE CONCRETE (f'c) = 2500 psi HORIZONTAL RE13AR REBAR (fLL= 601csi 04 RE5AR AT 10"oc ,4551 = 250 cf PASSIVE p � ACTIVE SOIL = 35 pcf 501L SEARING = 1500 psf 2 RE5AR SPL ICE 30' FOR 04 FOOTING 12' MIN BELOW GRADE. O RE5AR, 35" FOR 05 RE5AR BELOW GRADE IS NOT REQUIRED IF SLAB PRESENT WITH FOOTING RE5AR O FOOTING RE5AR *4 6 Im" O.C. 3 #4 HEEL RE5AR m 12" O C ALL VERTICAL5 . :OM 501E FACE) 5ACKFILL WITH 12" MINIMUM FREE Tec ismi2s UNIREFIRAINED CONCRETE WALL - 40 FF 5UIRCHAIRGE - 2 m18 IBC 36 D3 DRAINAGE - EXTERIOR CsR4DE5 ADJACENT TO THE WALL5 OF THE HOUSE ARE TO BE SLOPED AWAY FROM THE STRUCTURE TO ACHIEVE SURFACE DRAINAGE. SUBSURFACE DRAINS AT OR BELOW THE FOOTING/SLAB ELEVATION ARE TO BE USED FOR ANY BASEMENT OR RETAINING WALLS OVER 3 FEET IN HEIGHT. DR41N5 ARE TO GON515T OF RIGID PERFORATED 4' PVC PIPE SURROUNDED BT WASHED PEA -GRAVEL OR GRANULAR FILL WITH LESS THAN 59o,, FINES. PLACE A NONWOVEN -GEOTEXT ILE FILTER FABRIC BETWEEN THE DRAINAGE MATERIAL AND THE REMAINING WALL BACKFILL TO REDUCE SILT MIGRATION INTO THE DRAINAGE ZONE. PLACE THE FILTER FABRIC SUCH THAT IT FULL? 5EPARATE5 THE DRAINAGE MATERIAL AND THE BACKFILL AND EXTEND5 OVER THE TOP OF THE DRAINAGE ZONE. THE LEVEL OF THE PERFORATIONS IN THE PIPE ARE TO BE AT THE BOTTOM OF THE FOOTINGS AND THE DRAIN5 ARE TO BE CONSTRLIGTED WITH 5UFFICIENT GRADIENT TO ALLOW GRAVITY DISCHARGE AWAY FROM THE STRUCTURE. THE PERFORATIONS ARE TO BE LOCATED ON THE LOWER PORTION OF THE PIPE. RETAINING WALLS OR BASEMENTS WALLS ARE TO BE BACKFILLED WITH A MINIMUM 12 -INCH THICK WASHED GRAVEL BLANKET OR LINED WITH A DRAINAGE MAT 5UGH AS MIRA-DRAIN 6001 OR WELL GRADED AND DRAINING NATIVE SOILS OVER THE FULL HEIGHT OF THE WALLS (EXCLUDING THE FIRST I FOOT BELOW THE SURFACE). THIS DRAINAGE MATERIAL IS i0 TIE INTO THE FOOTING DRAIN SYSTEM. ROOF AND SUBAGE RUNOFF ARE NOT TO BE DISGNARCsED INTO THE FOOTING DRAIN SYSTEM D�45 41 AND SHOULD BE HANDLED BY A SEPARATE RIGID TICsNTLINE DRAIN SYSTEM. 37 D3 CONCRETE WALL DRAINAGE D3 32 6UJ21 5UJ31 OR 5UJ4 SWEAR PANEL 1 O 3x MEMBER At ADJOINING .0000/ PANEL EDGES FOR 51U2, \111*� SO AND SW4 SHEAR WALL SECTION lU/ (2)2X SCUD SECTION lU/ 2X SCUD ISUJI ONLY) O SO SWEAR WALL Sd NAIL: 4' EDGE - 12' FIELD SO SHEAR WALL ad NAIL: \ 3' EDGE - 12' FIELD 1 6W4 SHEAR WALL SD NAIL: 2' EDGE - 12' FIELD O 1/16' OSB SNEAtWINCx O 2x MEMBER AOR SHEAR WALLS MID PANEL (FIELD) SHEAR WALL PER PLAN O (2) 2X MAY 8E USED IN PLACE OF 3X PSR SHEAR WALL NOTES 6UJ1 SWEAR PANEL FOR COMPAR 15ON DRAINING SOILS, 12' OF DRAIN 5W21 5W31 5W4 SHEAR WALL NAILING SILL lU/FILtER FABRIC O )KEY (NOT REQUIRED IF SLAB � PRESENT At FOOTING) O FOOTING 12' MIN BELOW GRADE. O BELOW GRADE IS NOT REQUIRED IF SLAB PRESENT FOOTING t0 BEAR ON O FOOTING RE5AR *4 6 Im" O.C. FIRM UNDISTURBED WITH 3" COVER NATIVE SOIL OR OKEYWAY RE5AR t0 MATCH ENGINEERED SILL VERTICAL RE5AR SPACINC-.,� Tec ismi2s UNIREFIRAINED CONCRETE WALL - 40 FF 5UIRCHAIRGE - 2 m18 IBC 36 D3 DRAINAGE - EXTERIOR CsR4DE5 ADJACENT TO THE WALL5 OF THE HOUSE ARE TO BE SLOPED AWAY FROM THE STRUCTURE TO ACHIEVE SURFACE DRAINAGE. SUBSURFACE DRAINS AT OR BELOW THE FOOTING/SLAB ELEVATION ARE TO BE USED FOR ANY BASEMENT OR RETAINING WALLS OVER 3 FEET IN HEIGHT. DR41N5 ARE TO GON515T OF RIGID PERFORATED 4' PVC PIPE SURROUNDED BT WASHED PEA -GRAVEL OR GRANULAR FILL WITH LESS THAN 59o,, FINES. PLACE A NONWOVEN -GEOTEXT ILE FILTER FABRIC BETWEEN THE DRAINAGE MATERIAL AND THE REMAINING WALL BACKFILL TO REDUCE SILT MIGRATION INTO THE DRAINAGE ZONE. PLACE THE FILTER FABRIC SUCH THAT IT FULL? 5EPARATE5 THE DRAINAGE MATERIAL AND THE BACKFILL AND EXTEND5 OVER THE TOP OF THE DRAINAGE ZONE. THE LEVEL OF THE PERFORATIONS IN THE PIPE ARE TO BE AT THE BOTTOM OF THE FOOTINGS AND THE DRAIN5 ARE TO BE CONSTRLIGTED WITH 5UFFICIENT GRADIENT TO ALLOW GRAVITY DISCHARGE AWAY FROM THE STRUCTURE. THE PERFORATIONS ARE TO BE LOCATED ON THE LOWER PORTION OF THE PIPE. RETAINING WALLS OR BASEMENTS WALLS ARE TO BE BACKFILLED WITH A MINIMUM 12 -INCH THICK WASHED GRAVEL BLANKET OR LINED WITH A DRAINAGE MAT 5UGH AS MIRA-DRAIN 6001 OR WELL GRADED AND DRAINING NATIVE SOILS OVER THE FULL HEIGHT OF THE WALLS (EXCLUDING THE FIRST I FOOT BELOW THE SURFACE). THIS DRAINAGE MATERIAL IS i0 TIE INTO THE FOOTING DRAIN SYSTEM. ROOF AND SUBAGE RUNOFF ARE NOT TO BE DISGNARCsED INTO THE FOOTING DRAIN SYSTEM D�45 41 AND SHOULD BE HANDLED BY A SEPARATE RIGID TICsNTLINE DRAIN SYSTEM. 37 D3 CONCRETE WALL DRAINAGE D3 32 6UJ21 5UJ31 OR 5UJ4 SWEAR PANEL 1 O 3x MEMBER At ADJOINING .0000/ PANEL EDGES FOR 51U2, \111*� SO AND SW4 SHEAR WALL SECTION lU/ (2)2X SCUD SECTION lU/ 2X SCUD ISUJI ONLY) O SO SWEAR WALL Sd NAIL: 4' EDGE - 12' FIELD SO SHEAR WALL ad NAIL: \ 3' EDGE - 12' FIELD 1 6W4 SHEAR WALL SD NAIL: 2' EDGE - 12' FIELD O 1/16' OSB SNEAtWINCx O 2x MEMBER AOR SHEAR WALLS MID PANEL (FIELD) SHEAR WALL PER PLAN O (2) 2X MAY 8E USED IN PLACE OF 3X PSR SHEAR WALL NOTES 6UJ1 SWEAR PANEL FOR COMPAR 15ON 000 z 0 7n > W L C�70 L _ buoQ o -2-vi Z U 'N L O y' (6 ca •L N O O cLU a) W Q L U O 06 .1 L 55 a>) O 2 VO -82 itc aM:5 NaO V C Q N a) CO MCN a0)ui 0U 70 4 C t N O U N 'C m N-0 N 0 E0 �Nw ��cL Q U U U-0 N w j, O N -TC cc 0'-N (nCU-0U a -0, BUILDING CODE 2018 I5C WIND EXP. 5 91 MPSI SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 P5F ENG. P.E. JOIN W. DATE 03,11.2023 REVIEW ZACK C. ENGINEER IAN H. SHEET 9 OF1 0SHEETS PROJECT NUMBER 230114 23 COPYRIGHT cQ2023 I-IODCxE ENGINEERING, INC. DIGITALLY SIGNED MR Ub4G 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ GERIIFICATE MAY SE I�EhIOVID SY T4� JLp215DICTION 31 5W21 5W31 5W4 SHEAR WALL NAILING D3 O SHEAR WALL NAILING PER PLAN O SILL NAILING t0 RIM 16d a 4' O.C. 1 � O e SCRAP WHEN SPECIFIED O DOUBLE RIM JOIST REQUIRED FOR 6UJ2 OR GREATER 6NE,4RlUALL5 � O ATTACH BULL DEPTH BLOCKING TO DOUBLE TOP PLATS UJ/ (2) I0d a EACH BAY O FLOOR JOISt PER PLAN 2 � O In NAIL SUBFLOOR 70 BLOCKING lU/ Sd im 6' cc (UN.0) O STUD WALL OR BEAM PER PLAN O 1/1G' OSB SNEAtNINCx t0 S UNDERSIDE OF FLOOR JOISTS SDIUC EACH STUD TO DBL TOP PLATE. SDIUC FLOOR DTT2Z At CANTILEVERED JOISt 70 DBL COP (4 SDWC WALL ANDS WHEN TOTAL) WHEN NOLDOUIN TOTAL) SPECIFIED (U.N.O.) SPECIFIED 32 CANTILEVERED SHEAR WALL D3 1 (:D SWEAR WALL PER PLAN O 2x4 PRESSURE BLOCK • UJ/ (2) lmd 70� NAILED 2 � EACH END • O 2x BOttOM PLATE PER SNEARUJALL SCHEDULE 7 lU/ 16d 6 4' O.C. 4 (4)3/4" T 4G FLOORING O tRU55/R4FTER PER . „ PLAN � *WI EACH TRUSS (U.N.O.) • 1/16' OSB U1/ad 611O.C. � O PANEL EDGES 12'O.G. a FIELD OR GU18 lU/ 1-5/8' SCREWS. HANGER PER TRUSS (0 02x6 BLOCKING W/ 16da6"O.C, t0 COP � PLATS _ (p5EAM/RIM JOIST PER PLAN. EXTEND g SHEATHING OVER FACE / OR 2X10 BLOCKING BETWEEN CONTINUOUS STUDS 2x6 PRESSURE BLOCK UJ/ (2) lmd STAGGERED At (o 11 O.C. 33 JACK TRUSS 5HEAR TRANFER D3 000 z 0 7n > W L C�70 L _ buoQ o -2-vi Z U 'N L O y' (6 ca •L N O O cLU a) W Q L U O 06 .1 L 55 a>) O 2 VO -82 itc aM:5 NaO V C Q N a) CO MCN a0)ui 0U 70 4 C t N O U N 'C m N-0 N 0 E0 �Nw ��cL Q U U U-0 N w j, O N -TC cc 0'-N (nCU-0U a -0, BUILDING CODE 2018 I5C WIND EXP. 5 91 MPSI SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 P5F ENG. P.E. JOIN W. DATE 03,11.2023 REVIEW ZACK C. ENGINEER IAN H. SHEET 9 OF1 0SHEETS PROJECT NUMBER 230114 23 COPYRIGHT cQ2023 I-IODCxE ENGINEERING, INC. DIGITALLY SIGNED MR Ub4G 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ GERIIFICATE MAY SE I�EhIOVID SY T4� JLp215DICTION 1. GENERAL STRUCTURAL NOTES ALL LATERAL LOAD RESISTING AND GRAVITY LOAD RESISTING (IF SPECIFIED) STRUCTURAL MEMBERS ARE SHOWN ON THE ENGINEERING SHEETS AND DETAIL PAGES. THE ENCLOSED ENGINEERING CALCULATIONS DOCUMENT THE ANALYSIS USED TO DETERMINE THE STRUCTURAL MEMBERS OF THE ENGINEERING SHEETS. THE ENGINEERING CALCULATIONS ARE NOT REQUIRED TO BE REFERENCED FOR CONSTRUCTION AND ARE NOT REQUIRED BY ENGINEERING TO BE ONSITE. THIS ENGINEERING HAS BEEN CALCULATED TO RESIST CODE SPECIFIED VERTICAL AND LATERAL (WIND & SEISMIC) FORCES AFTER THE COMPLETION OF ALL STRUCTURAL ELEMENTS. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ENSURE STRUCTURAL STABILITY DURING CONSTRUCTION INCLUDING JOB SITE SAFETY; ERECTION METHODS; TEMPORARY SHORING, FORMWORK AND BRACING; USE OF EQUIPMENT AND CONSTRUCTION PROCEDURES. ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, ENGINEERING, AND/OR THE SITE CONDITIONS MUST BE REPORTED TO THE ARCHITECT AND ENGINEER WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL DIMENSIONS PRIOR TO CONSTRUCTION. STRUCTURAL DRAWINGS GOVERN. IF THERE ARE CONFLICTS WITH ARCHITECTURAL DRAWINGS, CONTACT HODGE ENGINEERING IMMEDIATELY. CONSTRUCTION OBSERVATION BY THE STRUCTURAL ENGINEER IS NOT PROVIDED. THIS ENGINEERING IS NOT INTENDED I N ANY WAY TO REVIEW OR APPROVE THE CONTRACTOR'S CONSTRUCTION PROCEDURES. STANDARDS ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2018 INTERNATIONAL BUILDING CODE (IBC) AS AMENDED AND ADOPTED BY THE LOCAL BUILDING OFFICIAL OR APPLICABLE JURISDICTION. THIS ENGINEERING IS TO THE 2018 INTERNATIONAL BUILDING CODE (IBC) 2. DESIGN CRITERIA VERTICAL LOADS IBC TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS USE LIVE LOAD ATTICS WITH STORAGE (UNINHABITABLE) 20 PSF ATTICS WITHOUT STORAGE (UNINHABITABLE) 10 PSF DECKS 60 PSF EXTERIOR BALCONIES 60 PSF FIRE ESCAPES 40 PSF GUARDRAILS AND HAND RAILS 200 POUNDS GUARD RAIL INFILL COMPONENTS 50 POUNDS PASSENGER VEHICLE GARAGES 40 PSF ROOMS OTHER THAN SLEEPING ROOMS 40 PSF SLEEPING ROOMS 30 PSF STAIRS 40 PSF LATERAL FORCES 1 ASCE 7-16 DIRECTIONAL PROCEDURE FOR BUILDINGS OF ALL HEIGHTS SEISMIC -- SEISMIC IMPORTANCE FACTOR PER ASCE 7-16, Ie = 1.00 BUILDING OCCUPANCY RISK CATEGORY PER ASCE 7-16 TABLE 1.5-1= II SOIL SITE CLASS PER ASCE 7-16 TABLE 20.3-1= PER PLAN SEISMIC DESIGN CATEGORY IBC TABLE 1613.2.5(1) & 1613.2.5(2) = PER PLAN ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE ANALYSIS RESPONSE MODIFICATION FACTOR R = 6.5 M411191" HODGE ENGINEERING IS NOT A GEOTECHNICAL ENGINEERING FIRM AND CANNOT MAKE A DETERMINATION OF SITE ADEQUACY FOR CONSTRUCTION. IF SITE SOIL BEARING CAPACITY OR SITE SLOPE IS IN DOUBT OR MAY AFFECT CONSTRUCTION THE BUILDER MUST CONTRACT A GEOTECHNICAL ENGINEERING FIRM FOR A SOILS REPORT. PROVIDE HODGE ENGINEERING WITH ANY GEOTECHNICAL INFORMATION PRIOR TO SITE PREPARATION. IF OWNER AND BUILDER THROUGH THEIR FEASIBILITY STUDIES DETERMINES THAT A GEOTECHNICAL REPORT IS NOT NEEDED THE FOLLOWING SOIL PARAMETERS AND METHODS ARE ASSUMED AND ACCEPTED BY THE OWNER AND BUILDER: SOIL BEARING PRESSURE: 1500 PSF (ASSUMED)* ACTIVE PRESSURE -UNRESTRAINED: 35 PCF (ASSUMED) PASSIVE RESISTANCE: 200 PCF (ASSUMED) COEFFICIENT OF FRICTION:.35 (ASSUMED) *1/3 INCREASE ALLOWED FOR SEISMIC OR WIND LOADING ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR COMPACTED STRUCTURAL FILL FOLLOWING SPECIFICATIONS NOTED BELOW. AREAS OVER -EXCAVATED SHALL BE BACKFILLED WITH LEAN CONCRETE (Fc=2000 PSI) OR COMPACTED STRUCTURAL BACKFILL. "STRUCTURAL BACKFILL" SHALL BE FILLED WITH APPROVED WELL -GRADED MATERIAL. MAXIMUM SIZE OF ROCK 4". ORGANIC MATERIAL AND DELETERIOUS MATTER NOT ALLOWED. COMPACT TO AT LEAST 95% OF IT'S MAXIMUM DENSITY AS DETERMINED BY ASTM D-1557. WHERE REQUIRED BY THE BUILDING OFFICIAL, THE CLASSIFICATION AND INVESTIGATION OF THE SOIL SHALL BE MADE BY A REGISTERED DESIGN PROFESSIONAL (IBC 1803.1). UNLESS A SOILS INVESTIGATION IS PROVIDED FOUNDATION DESIGN IS BASED ON AN ASSUMED AVERAGE SOIL BEARING OF 1500 PSF. ORGANIC SILT, ORGANIC CLAYS, PEAT OR UNPREPARED FILL SHALL NOT BE ASSUMED TO HAVE A BEARING CAPACITY. WHERE THE SOIL PROPERTIES ARE NOT KNOWN INSUFFICIENT DETAIL TO DETERMINE THE SITE CLASS, THIS ENGINEERING IS BASED ON 'DEFAULT' SITE CLASS D SOILS UNLESS THE BUILDING OFFICIAL OR GEOTECHNICAL DATA DETERMINES THAT SITE CLASS E OR F SOILS ARE PRESENT AT THE SITE IN ACCORDANCE WITH IBC TABLE 1613.2.5(1) & 1613.2.5(2). (UNLESS NOTED OTHERWISE) SITE GRADING: THE GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL BE SLOPED AWAY FROM THE BUILDING PER IBC 1804.4. EXPANSIVE SOILS SHALL BE REMOVED. FREE DRAINING BACKFILL MATERIAL FOR RETAINING AND BASEMENT WALLS CLEAN, FREE DRAINING, WELL GRADED SAND OR GRAVEL MATERIAL WHOSE MAXIMUM PARTICLE SIZE DOES NOT EXCEED 3/4" AND WHOSE FINES CONTENT (MATERIAL PASSING THE NO. 200 SIEVE) DOES NOT EXCEED 5%, WITH A MAXIMUM DUST RATIO %PASSING U.S. N0.200 SIEVE = 2/3 MAX. PASSING U.S. N0.400 SIEVE 4, CONCRETE CONCRETE WALLS EXCEEDING 8' IN HEIGHT MUST BE DESIGNED AND STAMPED BY A LICENSED PROFESSIONAL ENGINEER. IF CONCRETE WALLS OVER 8' HAVE BEEN DESIGNED FOR THIS PROJECT THEY WILL BE SPECIFIED ON THE PLAN AND SHOWN IN THE DETAILS. WOOD SHALL NOT BE USED TO SUPPORT MASONRY UNLESS SPECIFICALLY NOTED OTHERWISE ON THE S -SHEETS (IBC 2304.12). ALL BASEMENT WALLS BELOW FINISHED GRADE SHALL BE WATER PROOFED OUTSIDE BY APPROVED METHODS AND MATERIALS. CONCRETE: SHALL BE MADE WITH PORTLAND CEMENT ASTM C-150 TYPE II OR TYPE I AND SHALL BE READY MIXED PER ASTM C-94. MIX DESIGNS: THE CONTRACTOR SHALL DESIGN CONCRETE MIXES THAT MEET OR EXCEED THE REQUIREMENTS OF THE CONCRETE MIX TABLE FOR THE BEARING STRENGTH SPECIFIED. THE MIX DESIGNS SHALL FACILITATE ANTICIPATED PLACEMENT METHODS, WEATHER, TEMPERATURE, REBAR CONGESTION, AND ALL OTHER FACTORS REQUIRED TO PROVIDE A STRUCTURALLY SOUND AND ACCEPTABLE FINISHED PRODUCT. WATER REDUCING ADMIXTURES MAY BE USED TO MEET THESE REQUIREMENTS. MAXIMUM SLUMP SHALL BE 5". ADMIXTURES: ADMIXTURES SHALL BE BY MASTER BUILDERS, W.R. GRACE, OR PRE -APPROVED EQUAL. ALL MANUFACTURER'S RECOMMENDATIONS SHALL BE FOLLOWED. WATER: SHALL BE CLEAN AND POTABLE PROVIDE 3000 PSI @ 28 DAYS MINIMUM FOR DURABILITY AT BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS, PORCHES, CARPORT SLABS AND STEPS EXPOSED TO THE WEATHER AND FOR ALL GARAGE FLOOR SLABS. CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL BE NO LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT. NO SPECIAL INSPECTION FOR 3000 PSI CONCRETE - DURABILITY ONLY. REINFORCING STEEL: SHALL CONFORM TO ASTM A-615, GRADE 60. PLACE PER ACI 315 AND ACI 318. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE THE LONGEST LENGTHS PRACTICAL. WHERE SPLICES ARE NECESSARY THE LENGTH OF LAP SPLICE SHALL BE A MINIMUM OF 30 INCHES FOR #47 38 INCHES FOR #5, AND 45 INCHES FOR #6. THE MAXIMUM GAP BETWEEN NON -CONTACT PARALLEL BARS AT A LAP SPLICE SHALL NOT EXCEED 5 INCHES. CRACKS: UN -REINFORCED CONCRETE WILL CRACK. SLAB CRACK CONTROL IS RECOMMENDED IF CRACKS ARE UNDESIRABLE AND IS AS DIRECTED BY THE OWNER. OWNER IS TO DETERMINE THE ACCEPTABLE AMOUNT OF SLAB CRACKING PRIOR TO CONSTRUCTION AND REQUEST APPROPRIATE CRACK CONTROL. CONCRETE MINIMUM COVER OVER REINFORCEMENT CONCRETE CAST AGAINST EARTH = 3" EXPOSED TO WEATHER OR EARTH = 2" WALLS AND SLABS NOT EXPOSED TO WEATHER = 3/4" BOLTS MACHINE BOLTS (M.B.): ASTM A-307, GRADE A ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 36, CLASS 2A 5. CARPENTRY NAILS: CONNECTION DESIGNS ARE BASED ON "COMMON WIRE" NAILS WITH THE FOLLOWING PROPERTIES: PENNYWEIGHT DIAMETER (IN.) LENGTH (IN.) 8d MAX. 2-1/2 MIN. ITEM DESIGN f'c (PSI) MAX. W/C MIN. (2) AGGREGATE NOTES CEMENTITOUS 4 BOISE CASCADE RATIO FLYASH (PCY) SIZE (IN) AND WEB FILLER (1) MATERIAL 2x GANGLAM GALV (G185) MASONRY WALLS (4) CEILING JOIST NOT ATTACHED TO Fb=1700 PSI (SACKS/YARD) FOUNDATIONS 2500 @ 28 DAYS 0.45 - - 3/4 - - 5-1/2 STEMWALLS 3000 @ 28 DAYS 0.45 100 3/4 - - 5-1/2 SLAB ON GRADE 3000 @ 28 DAYS 0.45 100 3/4 END NAIL 5-1/2 CONCRETE FRAME 2500 @ 28 DAYS 0.45 100 3/4 - - 5-1/2 PROVIDE 3000 PSI @ 28 DAYS MINIMUM FOR DURABILITY AT BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS, PORCHES, CARPORT SLABS AND STEPS EXPOSED TO THE WEATHER AND FOR ALL GARAGE FLOOR SLABS. CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL BE NO LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT. NO SPECIAL INSPECTION FOR 3000 PSI CONCRETE - DURABILITY ONLY. REINFORCING STEEL: SHALL CONFORM TO ASTM A-615, GRADE 60. PLACE PER ACI 315 AND ACI 318. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE THE LONGEST LENGTHS PRACTICAL. WHERE SPLICES ARE NECESSARY THE LENGTH OF LAP SPLICE SHALL BE A MINIMUM OF 30 INCHES FOR #47 38 INCHES FOR #5, AND 45 INCHES FOR #6. THE MAXIMUM GAP BETWEEN NON -CONTACT PARALLEL BARS AT A LAP SPLICE SHALL NOT EXCEED 5 INCHES. CRACKS: UN -REINFORCED CONCRETE WILL CRACK. SLAB CRACK CONTROL IS RECOMMENDED IF CRACKS ARE UNDESIRABLE AND IS AS DIRECTED BY THE OWNER. OWNER IS TO DETERMINE THE ACCEPTABLE AMOUNT OF SLAB CRACKING PRIOR TO CONSTRUCTION AND REQUEST APPROPRIATE CRACK CONTROL. CONCRETE MINIMUM COVER OVER REINFORCEMENT CONCRETE CAST AGAINST EARTH = 3" EXPOSED TO WEATHER OR EARTH = 2" WALLS AND SLABS NOT EXPOSED TO WEATHER = 3/4" BOLTS MACHINE BOLTS (M.B.): ASTM A-307, GRADE A ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 36, CLASS 2A 5. CARPENTRY NAILS: CONNECTION DESIGNS ARE BASED ON "COMMON WIRE" NAILS WITH THE FOLLOWING PROPERTIES: PENNYWEIGHT DIAMETER (IN.) LENGTH (IN.) 8d 0.131 2-1/2 10d 0.148 3 16d 0.162 3-1/2 20d 0.192 4 WOOD SHEATHING (STRUCTURAL): SHEATHING SHALL BE PLYWOOD (CDX) OR ORIENTED STRAND BOARD (OSB). PLYWOOD SHEATHING SHALL BE 5 -PLY MINIMUM WHERE INDICATED AS 3/4" OR THICKER. WOOD SHEATHING SHALL BE "RATED SHEATHING" CONFORMING TO PSI -95 AND/OR PS2-92. ALL PANELS SHALL BEAR THE STAMP OF AN APPROVED GRADING AGENCY. SPAN RATING SHALL BE PROVIDED AS FOLLOWS: ROOF (24/16); WALLS (24/16); FLOORS (2011 O.C.) UNLESS NOTED OTHERWISE. ALL WOOD SHEATHED WALLS SHALL BE BLOCKED AT ALL PANEL EDGES UNLESS NOTED OTHERWISE. GLUE -LAMINATED MEMBERS: PER ANSI/RITC A190.1. MEMBERS SHALL BE COMBINATION 24F -V4 DOUGLAS FIR FOR SIMPLE SPANS AND 24F -V8 DOUGLAS FIR FOR CANTILEVERED SPANS AND TRUSS CHORDS (FB=2400 PSI, FV=240 PSI, E=1.8X10^6 PSI) AND DOUGLAS FIR COMBINATION 3 FOR COLUMNS AND TRUSS WEB MEMBERS, ALL WITH EXTERIOR GLUE. ALL MEMBERS TO HAVE AITC OR APA-EWS STAMP. FRAMING LUMBER: EACH PIECE SHALL BEAR THE GRADE TRADEMARK OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB), WESTERN WOOD PRODUCTS ASSOCIATION (WWPA), OR OTHER AGENCY ACCREDITED BE THE AMERICAN LUMBER STANDARD COMMITTEE (ALSC) TO GRADE UNDER ALSC CERTIFIED GRADING RULES. SPECIES AND GRADE (BASE DESIGN VALUE) (U.N.O.) 1. 2X TO 4X JOISTS, PURLINS AND HEADERS. "DOUG FIR -LARCH" NO. 2 (Fb=900 PSI, Fv=180 PSI) OR "HEM -FIR" NO. 1 (Fb=975 PSI, Fv=150 PSI) 2. 6X POSTS AND COLUMNS. "DOUG FIR -LARCH" NO. 1(Fc=1000 PSI) 3. EXTERIOR STUDS, INTERIOR BEARING WALLS "HEM -FIR" NO. 2 4. INTERIOR NON-BEARING STUD WALLS. "HEM -FIR" NO. 2 STUD GRADE 5. 2X & 3X T&G DECKING: "DOUG FIR -LARCH" COMMERCIAL (Fb=1650 PSI, E=1700 KSI) COLUMNS: ALL COLUMNS NOT SPECIFIED OR OTHERWISE NOTED ON THE PLAN ARE TO BE TWO STUDS. MULTIPLE STUDS ARE TO BE SPIKE LAMINATED TOGETHER WITH (2)16d NAILING AT 6" ON CENTER STAGGERED (U.N.O.). ALL COLUMNS SUPPORTING GIRDER TRUSSES OR GLUE LAMINATED BEAMS ARE TO BE THREE STUDS. ALL BEARING WALLS OVER 10' SHALL BE LATERALLY BRACED AT 4' O.C. CONTRACTOR SHALL VERIFY ALL POINT LOADS ARE SUPPORTED TO THE FOUNDATION. FLOORING AND ROOFING: PLYWOOD SUBFLOORING SHALL BE 4" T&G CDX GLUED AND NAILED. NAILING SHALL BE 8d @ 6" O.C. ALONG PANEL EDGES, AND 12" O.C. IN FIELD. STAGGER END LAPS. ROOF SHEATHING SHALL BE 2" CDX OR 16" OSB NAILED WITH 8d @ 6" O.C. ALONG PANEL EDGES AND 12" O.C. IN THE FIELD. STAGGER END LAPS. FRAMING LUMBER (MANUFACTURED): SHALL BE MANUFACTURED BY THE FOLLOWING MANUFACTURERS IN ACCORDANCE WITH APPROVED SHOP AND INSTALLATION DRAWINGS. APPROVED MANUFACTURERS ITEM PRESERVATIVE CONNECTORS & APPLICATION SPECIFIED MATERIAL TREATMENT (1) SPECIFIED FOUNDATION SILL LOUISIANA ROSEBURG FOREST GEORGIA MEMBER TRUS-JOIST BOISE CASCADE PACIFIC PRODUCTS PACIFIC AND WEB FILLER 2x TIMBERSTRAND 2x GANGLAM GALV (G185) MASONRY WALLS (4) CEILING JOIST NOT ATTACHED TO Fb=1700 PSI (3)16d Fb=2250 PSI 2X, & 4X (FIR) ACQ, CBA, CA 2x SCL FRAMING, DECKING, PARALLEL RAFTER (HEEL JOINT) FACE NAIL 2X, & 4X (CEDAR) NONE E=1300 KSI POSTS & LEDGERS E=1500 KSI 6X OR GLULAM (FIR) ACQ, CBA, CA GALV (G185) Fv=400 PSI 6X OR GLULAM Fv=275 PSI END NAIL I I (CEDAR) 1-3/4" PARALLAM 1-3/4" VERSALAM 1-3/4" LP LVL 1-3/4" RIGID -LAM 1-3/4" G -P -LAM 1-3/4" SCL Fb=2900 PSI Fb=2800 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI (NOT AT BRACED WALL PANELS) E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI AT INTERSECTING WALL CORNERS Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI (2" TO 2" HEADER) 3-1/2" PARALLAM 3-1/2" VERSALAM 3-1/2" LP LVL 3-1/2" RIGID -LAM 2 -PLY G -P -LAM* 3-1/2" SCL Fb=2900 PSI Fb=3100 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI AT END JOINTS E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI BAND JOIST (NOT AT BRACED PANEL) Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI BAND JOIST AT BRACED PANEL 5-1/4" PARALLAM 5-1/4" VERSALAM 5-1/4" LP LVL 5-1/4" RIGID -LAM 3 -PLY G -P -LAM* 5-1/4" SCL Fb=2900 PSI Fb=3100 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI TOP PLATES, LAPS AT CORNERS AND E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI JOIST TO STILL, TOP PLATE OR Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI RIM JOIST/BAND JOIST OR BLOCKING 7" PARALLAM 7" VERSALAM 7" LP LVL 7" RIGID -LAM 4 -PLY G -P -LAM* 2" SUBFLOOR TO JOIST OR GIRDER Fb=2900 PSI Fb=3100 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI 7" SCL E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI 2 LUMBER LAYERS Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI RIM BOARD OR APA / EWS PERFORMANCE RATED RIM (PRR-401) 1-1/8" MINIMUM THICKNESS RIM JOIST JOIST TO BAND/RIM JOIST * - CONNECT MULTI -PLY MEMBERS PER MANUFACTURER'S RECOMMENDATIONS - LSL's MAY BE USED IN PLACE OF LVL's WHEN SPECIFIED - PRESERVATIVE TREATED WOOD REQUIREMENTS: IBC 2304.12: WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WITHOUT JOISTS SHALL NOT BE CLOSER THAN 18 INCHES, OR WOOD GIRDERS CLOSER THAN 12 INCHES TO THE EXPOSED GROUND IN CRAWL SPACES. WOOD FRAMING MEMBERS, INCLUDING WOOD SHEATHING, WHICH REST ON EXTERIOR FOUNDATION WALLS SHALL NOT BE LESS THAN 8 INCHES FROM EXPOSED EARTH. SILLS IN CONTACT WITH CONCRETE SHALL BE PRESERVATIVE -TREATED WOOD. CLEARANCE BETWEEN WOOD SIDING AND EARTH SHALL NOT BE LESS THAN 6 INCHES. POSTS SHALL BE PRESERVATIVE -TREATED UNLESS SUPPORTED BY A PEDESTAL GREATER THAN 8 INCHES FROM EXPOSED GROUND. w 0 W PRESERVATIVE TREATED WOOD FASTENER REQUIREMENTS: ALL METAL CONNECTORS LESS THAN 1/2" DIAMETER (R317.3.1) COMING IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE SIMPSON Z -MAX, TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED. CCA: CHROMATED COPPER ARSENATE NOT PERMITTED. SBX: DOT SODIUM BORATE ACQ: ALKALINE COPPER QUAT CBA AND CA: COPPER AZOLE G607 G90, AND G185 PER ASTM A23 FOR CONNECTORS, AND ASTM A153 FOR FASTENERS. MECHANICALLY GALVANIZED FASTENERS PER ASTM B695, CLASS 55 OR GREATER. GENERAL CARPENTRY NOTES: STAGGER ALL NAILING TO PREVENT SPLITTING OF WOOD MEMBERS. PRESSURE -TREAT ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY. HOLES AND CUTS IN PLATES SHOULD BE TREATED WITH A 20% SOLUTION OF COPPER NAPHTHENATE. BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. PROVIDE CUT WASHERS WHERE BOLT HEADS, NUTS AND LAG SCREW HEADS BEAR ON WOOD. PROVIDE A MINIMUM 3x3x.229 PLATE WASHER ON ALL ANCHOR BOLTS WHICH CONNECT MUD SILLS TO FOUNDATION. DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS TABLE FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. GOOD FRAMING PRACTICE TO USE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND MORE THAN 2 THE LENGTH AND AROUND OPENINGS UNLESS DESIGNED BY A FLOOR JOIST MANUFACTURER. POSITIVE CONNECTIONS SHALL BE PROVIDED AT POST -BEAM CONNECTIONS TO ENSURE AGAINST UPLIFT AND LATERAL DISPLACEMENT. USE 12" CS -14 UNLESS NOTED OTHERWISE. METAL -PLATE -CONNECTED WOOD TRUSSES: SHALL SPECIAL INSPECTIONS OF WOOD TRUSSES WITH OVERALL HEIGHTS OF 60 INCHES OR GREATER SHALL BE PERFORMED TO VERIFY THAT THE INSTALLATION OF THE PERMANENT INDIVIDUAL TRUSS MEMBER RESTRAINT/BRACING HAS BEEN INSTALLED IN ACCORDANCE WITH THE APPROVED TRUSS SUBMITTAL PACKAGE. FOR WOOD TRUSSES WITH A CLEAR SPAN OF 60 FEET OR GREATER, THE SPECIAL INSPECTOR SHALL VERIFY DURING CONSTRUCTION THAT THE TEMPORARY INSTALLATION RESTRAINT/BRACING IS INSTALLED IN ACCORDANCE WITH THE APPROVED TRUSS SUBMITTAL PACKAGE. FASTENING SCHEDULE FOR WOOD STRUCTURAL MEMBERS IBC 2304.10.1 ITEM PRESERVATIVE CONNECTORS & APPLICATION SPECIFIED MATERIAL TREATMENT (1) FASTENERS (2)(3) FOUNDATION SILL BLOCKING AT RAFTERS/TRUSS NOT TOENAIL, EACH END PLATES, TOP PLATES & 2X, 4X, 6X OR GLULAM SBX GALV (G60) LEDGERS ON (FIR) 16d @ 6" O.C. AND WEB FILLER CONCRETE OR ACQ, CBA, CA GALV (G185) MASONRY WALLS (4) CEILING JOIST NOT ATTACHED TO FACE NAIL (3)16d PARALLEL RAFTER, LAPS OVER PARTITION 2X, & 4X (FIR) ACQ, CBA, CA GALV (G185) FRAMING, DECKING, PARALLEL RAFTER (HEEL JOINT) FACE NAIL 2X, & 4X (CEDAR) NONE GALV (G90) POSTS & LEDGERS RAFTER OR ROOF TRUSS TO TOP 6X OR GLULAM (FIR) ACQ, CBA, CA GALV (G185) BEAMS AND COLUMNS 6X OR GLULAM RAFTERS TO RIDGE VALLEY/ HIP END NAIL I I (CEDAR) NONE GALV (G90) PRESERVATIVE TREATED WOOD FASTENER REQUIREMENTS: ALL METAL CONNECTORS LESS THAN 1/2" DIAMETER (R317.3.1) COMING IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE SIMPSON Z -MAX, TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED. CCA: CHROMATED COPPER ARSENATE NOT PERMITTED. SBX: DOT SODIUM BORATE ACQ: ALKALINE COPPER QUAT CBA AND CA: COPPER AZOLE G607 G90, AND G185 PER ASTM A23 FOR CONNECTORS, AND ASTM A153 FOR FASTENERS. MECHANICALLY GALVANIZED FASTENERS PER ASTM B695, CLASS 55 OR GREATER. GENERAL CARPENTRY NOTES: STAGGER ALL NAILING TO PREVENT SPLITTING OF WOOD MEMBERS. PRESSURE -TREAT ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY. HOLES AND CUTS IN PLATES SHOULD BE TREATED WITH A 20% SOLUTION OF COPPER NAPHTHENATE. BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. PROVIDE CUT WASHERS WHERE BOLT HEADS, NUTS AND LAG SCREW HEADS BEAR ON WOOD. PROVIDE A MINIMUM 3x3x.229 PLATE WASHER ON ALL ANCHOR BOLTS WHICH CONNECT MUD SILLS TO FOUNDATION. DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS TABLE FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. GOOD FRAMING PRACTICE TO USE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND MORE THAN 2 THE LENGTH AND AROUND OPENINGS UNLESS DESIGNED BY A FLOOR JOIST MANUFACTURER. POSITIVE CONNECTIONS SHALL BE PROVIDED AT POST -BEAM CONNECTIONS TO ENSURE AGAINST UPLIFT AND LATERAL DISPLACEMENT. USE 12" CS -14 UNLESS NOTED OTHERWISE. METAL -PLATE -CONNECTED WOOD TRUSSES: SHALL SPECIAL INSPECTIONS OF WOOD TRUSSES WITH OVERALL HEIGHTS OF 60 INCHES OR GREATER SHALL BE PERFORMED TO VERIFY THAT THE INSTALLATION OF THE PERMANENT INDIVIDUAL TRUSS MEMBER RESTRAINT/BRACING HAS BEEN INSTALLED IN ACCORDANCE WITH THE APPROVED TRUSS SUBMITTAL PACKAGE. FOR WOOD TRUSSES WITH A CLEAR SPAN OF 60 FEET OR GREATER, THE SPECIAL INSPECTOR SHALL VERIFY DURING CONSTRUCTION THAT THE TEMPORARY INSTALLATION RESTRAINT/BRACING IS INSTALLED IN ACCORDANCE WITH THE APPROVED TRUSS SUBMITTAL PACKAGE. FASTENING SCHEDULE FOR WOOD STRUCTURAL MEMBERS IBC 2304.10.1 ITEM TYPE CONNECTION BLOCKING BETWEEN CEILING JOISTS, TOENAIL, EACH END (3) 8d RAFTERS/TRUSSES TO TOP PLATE BLOCKING AT RAFTERS/TRUSS NOT TOENAIL, EACH END (2) 8d AT WALL TOP PLATE/RAFTER/TRUSS FLAT BLOCKING TO TRUSS FACE NAIL 16d @ 6" O.C. AND WEB FILLER CEILING JOISTS TO TOP PLATE TOENAIL, EACH JOIST (3) 8d CEILING JOIST NOT ATTACHED TO FACE NAIL (3)16d PARALLEL RAFTER, LAPS OVER PARTITION CEILING JOIST ATTACHED TO PARALLEL RAFTER (HEEL JOINT) FACE NAIL PER TABLE 2308.7.3.1 COLLAR TIE TO RAFTER FACE NAIL (3)10d RAFTER OR ROOF TRUSS TO TOP TOENAIL (3)10d PLATE RAFTERS TO RIDGE VALLEY/ HIP END NAIL (2)16d RAFTERS, OR RAFTER TO 2" RIDGE RAFTERS TO RIDGE VALLEY/ HIP TOENAIL (3)10d RAFTERS, OR RAFTER TO 2" RIDGE STUD TO STUD (NOT AT BRACED WALL PANELS) FACE NAIL 16d @ 24" O.C. STUD TO STUD AND ABUTTING STUDS FACE NAIL 16d @ 16" O.C. AT INTERSECTING WALL CORNERS BUILT-UP HEADER FACE NAIL, EACH EDGE 16d @ 16" O.C. (2" TO 2" HEADER) CONTINUOUS HEADER TO STUD TOENAIL (4) 8d TOP PLATE TO TOP PLATE FACE NAIL 16d @ 16" O.C. TOP PLATE TO TOP PLATE, END JOINT, FACE NAIL (8)16d, EACH SIDE END JOINT, AT END JOINTS FACE NAIL (M IN 24" LAP SPLICE) BOTTOM PLATE TO JOIST/RIM JOIST/ BAND JOIST (NOT AT BRACED PANEL) FACE NAIL 16d @ 16" O.C. BOTTOM PLATE TO JOIST/RIM JOIST/ FACE NAIL (2) 16d @ 16" O.C. BAND JOIST AT BRACED PANEL STUD TO TOP OR BOTTOM PLATE TOENAIL (4) 8d STUD TO TOP OR BOTTOM PLATE END NAIL (2)16d TOP OR BOTTOM PLATE STUD END NAIL (2)16d TOP PLATES, LAPS AT CORNERS AND FACE NAIL (2)16d INTERSECTIONS JOIST TO STILL, TOP PLATE OR TOENAIL (3) 8d GIRDER RIM JOIST/BAND JOIST OR BLOCKING TO TOP PLATE/SILL/FRAMING BELOW TOENAIL 8d @ 6" O.C. 2" SUBFLOOR TO JOIST OR GIRDER FACE NAIL (2)16d 2" PLANKS FACE NAIL, EACH BEARING (2)16d (PLANK & BEAM - FLOOR & ROOF) BUILT-UP GIRDERS AND BEAMS FACE NAIL AT TOP AND BOTTOM 20d @ 32" O.C. 2 LUMBER LAYERS STAGGERED ON OPPOSITE SIDES LEDGER STRIP SUPPORTING JOISTS FACE NAIL, EACH JOIST OR RAFTER (3)16d OR RAFTERS JOIST TO BAND/RIM JOIST END NAIL (3)16d BRIDGING/BLOCKING TO TOENAIL, EACH END (2) 8d JOIST, RAFTER OR TRUSS CONNECTIONS ARE COMMON NAILS U.N.O LAG SCREWS: SHALL BE OF A DIAMETER INDICATED ON DRAWINGS WITH A MINIMUM OF 8x DIAMETER EMBEDMENT IN SUPPORTING MEMBER UNLESS NOTED OTHERWISE. CLEARANCE HOLE FOR THE SHANK SHALL BE THE SAME DIAMETER AS THE SHANK AND THE SAME DEPTH OF PENETRATION AS THE UNTHREADED PORTION OF THE SHANK. THE LEAD HOLE FOR THE THREADED PORTION SHALL HAVE A DIAMETER EQUAL TO 60 TO 75% OF THE SHANK DIAMETER AND A LENGTH EQUAL TO AT LEAST THE LENGTH OF THE THREADED PORTION. THE THREADED PORTION OF THE SCREW SHALL BE INSERTED IN ITS LEAD HOLE BY TURNING WITH A WRENCH, NOT BY DRIVING WITH A HAMMER. SOAP OR OTHER LUBRICANT SHALL BE USED ON THE SCREWS OR IN THE LEAD HOLE TO FACILITATE INSERTION AND TO PREVENT DAMAGE TO THE SCREW. METAL PLATE CONNECTED WOOD TRUSSES: SHALL BE MANUFACTURED BY AN APPROVED TRUSS MANUFACTURER IN ACCORDANCE WITH APPROVED SHOP AND INSTALLATION DRAWINGS. ALL ROOF TRUSSES ARE TO BE PRE-ENGINEERED BY OTHERS. ROOF TRUSSES SHALL BE PROVIDED TO COMPLETE THE ROOF FRAMING FROM THE SHEATHING TO THE SUPPORTING MEMBERS BELOW. SHOP DRAWINGS AND CALCULATIONS SHALL BE PRODUCED UNDER THE SUPERVISION OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE ADDRESSED ON THIS ENGINEERING. DETAIL DRAWINGS TO INDICATE ALL INFORMATION AS REQUIRED IN IBC 2303.4.1.1 INCLUDING PERMANENT LATERAL BRACING AND CONNECTION DETAILS. -JOISTS: SHALL BE APA EWS PERFORMANCE RATED I -JOISTS (PRI). I -JOISTS SHALL BE MANUFACTURED IN CONFORMANCE WITH APA PRI -400 CONFORMING TO APPROVED SHOP AND INSTALLATION DRAWINGS. L 0 _ Sao w 13Q �° ) vi v fii •L N .O O cLU �� LJ.I ��Q�>to i6 J L i L c 0 C c V �;�� a ;