Loading...
JB0000511111 - K20-Yelm SD DC Move - SOW1 - COVER SHEET 2 -LEGEND 3 -GENERAL NOTES 4 -DETAILS 5-6 -DESIGNTHIS IS PROPRIETARY INFORMATION AND NOT MEANT FOR GENERAL PUBLICATION. ALL RIGHTS RESERVED CANNON COMPANIES 96 CT FIBER: 1,005 FT + 20% STORAGE = 1,206 FT 24 CT FIBER: 615 FT + 20% STORAGE = 738 FT CONTACTS: PROJECT MAP: *ALL FOOTAGES AND MATERIALS ARE ESTIMATED N SCOPE OF WORK: SHEET INDEX: BILL OF MATERIALS*: NEW AERIAL = OVERLASH = NEW UNDERGROUND = EXISTING UNDERGROUND = RISER (1)= TOTAL FOOTAGE = 0 FT. 1,005 FT. 10 FT. 580 FT. 25 FT. 1,620 FT. PROJECT DESCRIPTION - ROW* NEW BUILDING PATH WAY = EXISTING BUILDING PATH WAY = NEW UNDERGROUND = EXISTING UNDERGROUND = TOTAL FOOTAGE = 0 FT. 0 FT. 0 FT. 0 FT. 0 FT. PROJECT DESCRIPTION -SITE* TOTAL PROJECT FOOTAGE =1,620 FT. 1. TIE INTO SPLICE CASE SP.WATF.0142 WITH (1) 96CT FIBER & LEAVE COIL 2. OVERLASH (1) 96CT FIBER ON EXISTING AERIAL STRAND 3. PLACE TRANSITION CASE AND TRANSITION INTO 24CT FIBER & LEAVE COIL 4. OVERLASH (1) 24CT FIBER ON EXISTING AERIAL STRAND 5. PLACE (1) 4" RISER AND PULL (1) 24CT FIBER THROUGH 6. TRENCH (1) 4" CONDUIT AND PULL (1) 24CT FIBER TO GC PLACED VAULT 7. PROOF & PULL (1) 24CT FIBER THROUGH GC PLACED 4" CONDUIT CANNON COMPANIES SAFETY | QUALITY | INTEGRITY | TEAMWORK Connecting The Future Since 1985 COMCAST Business/Job Contact POC:ZACHARY MENDEL 360-870-9597 EMAIL: 'ZACHARY_MENDEL@YCS.WEDNET.EDU Review _________________________ CANNON COMPANIES Alex Gaunt - (206)-856-3583 - agaunt@cannonconstructioninc.com COMCAST COMMUNICATION Todd Zimny - (360)-507-0598 - Todd_Zimny@cable.comcast.com 401 COATES AVE NW YELM, WA 98597 K20-YELM SD DC MOVE JB#0000511111 EDGE OF PAVEMENT FOGLINE POWER COMMUNICATION SEWER DRAIN DRAINAGE DITCH GAS WATER TRAFFIC SIGNAL TELCOM STEAM UNKNOWN UTILITY RIGHT OF WAY TRAFFIC CONES PROPOSED NEW BORE STRAW WATTLES P LT CW R UTILITY POLE VAULT - SMALL PEDESTAL STREET LIGHT CROSSWALK LIGHT UTILITY RISER V VAULT - SMALL 444LA MANHOLE VAULT - 25TA CATCH BASIN CATCH BASIN WITH SOCK GLULAM UTILITY POLECENTER LINE LANE LINE FENCE HIGH VISIBILITY FENCE S SEWER MANHOLE D DRAIN MANHOLE W WATER MANHOLE V UTILITY VALVE SHRUBBERY BORE PIT VAULT - LARGE VAULT - 25TA C COMMUNICATION MANHOLE FIRE HYDRANT DISTANCE STATIONSTA 0+00 CONSTRUCTION NOTE CALLOUT# X.X DISTANCE DIMENSION ASPHALT SURFACE CONCRETE SIDEWALK PANEL CONCRETE ROADWAY PANEL HF H-FRAME VAULT - LARGE C C CAB CABINET LEGEND LANE DIRECTION INDICATOR PROPOSED MARK-UP NOTATIONS RESTORATION TYPESEXISTING FEATURESLINE TYPES A 7 LANDSCAPE CROSS SECTION SYMBOL CROSS SECTION NAME CROSS SECTION SHOWN ON PAGE FL FL EOP P P TS TS C C D D DD DD DD DD DD DD G G W W T T ST ST ROW S UK CB CB P P V V V V VV WORK BEING DONE1LOCATION PHOTO NOTE CALLOUT #PHOTO LOCATOR SYMBOL PROPOSED NEW TRENCH PROPOSED NEW AERIAL STRAND OF DATE REVISION BY QC CANNON COMPANIES 0000511111K20-YELM SD DC MOVE 401 COATES AVE NW YELM, WA 98597 LEGEND 2 6 12/17/2020 AB AF COMCAST GENERAL NOTES STANDARD 1. THE LOCATIONS OF UTILITIES SHOWN ON THE PLANS ARE APPROXIMATE. ALL UTILITY LOCATIONS SHALL BE VERIFIED PRIOR TO CONSTRUCTION. THE CONTRACTOR, AT HIS OWN EXPENSE, SHALL MAKE EXCAVATIONS AND BORINGS AHEAD OF THE WORK, AS NECESSARY, TO DETERMINE THE EXACT LOCATIONS OF UTILITIES AND UNDERGROUND STRUCTURES. IT IS UNDERSTOOD THAT THERE WILL BE INTERFERING UTILITIES AND OTHER UNDERGROUND PIPES, DRAINS OR STRUCTURES ENCOUNTERED THAT ARE NOT SHOWN OR AREAS SHOWN INCORRECTLY ON THE PLANS OR THAT HAVE NOT BEEN PREVIOUSLY DISCOVERED IN THE FIELD. THE CONTRACTOR AGREES THIS IS A NORMAL AND USUAL OCCURRENCE IN THE CONSTRUCTION OF UNDERGROUND IMPROVEMENTS. FURTHERMORE, CONTRACTORS UNDERSTAND AND AGREE THAT WORK IN SOME CASES PROPOSED PATH MAYBE IN CLOSE PROXIMITY TO SAID UTILITIES AND UNDERGROUND PIPES, DRAINS AND STRUCTURES NOT SHOWN ON THE PLANS WHICH MAY REQUIRE A CHANGE IN OPERATIONS AND MAY CAUSE SLOUGHING OF THE TRENCH, ADDITIONAL TRAFFIC CONTROL, ADDITIONAL PAVEMENT AND BACKFILL COSTS AND TIME. THE CONTRACTOR AGREES THAT A REASONABLE NUMBER OF THESE OCCURRENCES IS USUAL AND ORDINARY, AND ARE REFLECTED IN THE BID AND PLAN OF OPERATION. THE CONTRACTORS AGREES TO PROVIDE FOR THESE CONFLICTS AND AGREES TO PROVIDE FOR A REASONABLE AMOUNT OF TIME FOR DESIGN CHANGES AND/OR UTILITY RELOCATIONS DUE TO SAID CONFLICTS. 2. CALL THE UTILITIES UNDERGROUND LOCATION CENTER AT 811 3. INSPECTIONS - THE CONTRACTOR SHALL NOTIFY LOCAL JURISDICTIONS FOR REQUIRED INSPECTION SERVICES. 4. EXCESS WATER - SHOULD WATER BE ENCOUNTERED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DEWATER, AS PER LOCAL JURISDICTIONS STANDARD SPECIFICATIONS, BEFORE CONSTRUCTION CONTINUES. 5. NO SILT LADEN WATER IS TO BE DISCHARGED FROM THE SITE WITHOUT PASSING THROUGH AN EROSION CONTROL SYSTEM. 6. THE CONTRACTOR SHALL SCHEDULE AND CONTROL HIS/HER WORK SO AS TO COMPLY WITH ALL APPLICABLE ORDINANCES TO PREVENT ANY HAZARDS TO PUBLIC SAFETY, HEALTH AND WELFARE. 7. ALL STREETS SHALL BE KEPT FREE OF DIRT AND DEBRIS ON A CONTINUOUS BASIS. 8. AN APPROVED COPY OF THESE PLANS WILL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING THE PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 10. PEDESTRIAN AND VEHICULAR ACCESS TO ADJACENT PROPERTIES SHALL BE MAINTAINED AT ALL TIMES EXCEPT WHERE PRIOR WRITTEN APPROVAL FROM THE PROPERTY OWNER HAS BEEN OBTAINED. 11. BARRICADE OPEN DEPRESSIONS AND HOLES OCCURRING AS PART OF THIS WORK, AND POST WARNING LIGHTS ON ADJACENT PROPERTIES WITH PUBLIC ACCESS. OPERATE WARNING LIGHTS DURING HOURS FROM DUSK TO DAWN EACH DAY AND AS OTHERWISE REQUIRED. 12. PROTECT STRUCTURES, UTILITIES, PAVEMENTS, AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL MOVEMENT, UNDERMINING WASHOUT AND OTHER HAZARDS CREATED BY OPERATIONS UNDER THIS SECTION. TRAFFIC CONTROL 1. THE CONTRACTOR IS ADVISED THAT ALL LANE CLOSURES SHALL BE KEPT TO A MINIMUM. LOCAL JURISDICTIONS WILL APPROVE ONLY THOSE LANE AND ROADWAY CLOSURES DETERMINED TO BE NECESSARY FOR THE CONTRACTOR TO ACCOMPLISH A SPECIFIC TASK. NO LANE OR ROADWAY CLOSURES WILL BE PERMITTED WITHOUT PRIOR APPROVALS. 2. THE CONTRACTOR SHALL KEEP ALL TRAFFIC LANES AND SHOULDERS CLEAR OF EQUIPMENT AND MATERIALS DURING NON-WORKING HOURS. EQUIPMENT AND MATERIALS SHALL NOT BE STORED ON THE STREETS. THE CONTRACTOR'S EMPLOYEES AND AGENTS SHALL NOT PARK PRIVATE VEHICLES ALONG THE ROADWAY OR MEDIAN. SITE PREPARATION 1. SOD AND LAWN TO BE REMOVED SHALL BE CUT TO A NEAT VERTICAL LINE 6" MINIMUM BEYOND THE TRENCH LINE. SOD SHALL BE EITHER REMOVED FROM THE SITE, OR CAREFULLY STOCKPILED FOR REUSE. 2. SAW CUT PAVEMENT TO A NEAT VERTICAL LINE 8" TO 12" MINIMUM BEYOND THE TRENCH LINE. REPLACE PAVEMENT WITH LIKE MATERIAL (I.E., ASPHALT WITH ASPHALT, CONCRETE WITH CONCRETE). 3. EXCEPT AS NOTED HEREIN, ALL MATERIAL REMOVED SHALL BE TAKEN FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR. TRENCH EXCAVATION AND BACKFILL 1. TRENCH BACKFILL - WHERE MATERIAL EXCAVATED FROM TRENCHES IS UNSUITABLE FOR BACKFILL, THE CONTRACTOR SHALL BACKFILL WITH BANK RUN GRAVEL OR MAY ELECT TO USE CDF IN LIEU OF THE COMPACTION/PROCTOR PROCESS. STONEWAY MIX 351 IS ACCEPTABLE IN ALL LOCATIONS. QUICK SETTING MIX 1004 IS ACCEPTABLE IN NON-TRAFFIC AREAS. MIX 1121 IS TO BE USED IN TRAFFIC-BEARING LOCATIONS. 2. COMPACTION, WHEN NECESSARY, SHALL BE PERFORMED IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS. UTILITY DUCT 1. BURIED DUCT SHALL BE (1) 4" SCHEDULE 40 PVC, UNLESS NOTED OTHERWISE. MINIMUM CONDUIT COVER SHALL BE 36" WITH A MINIMUM SLOPE OF 1/2 % TO VAULT. 2. THOROUGHLY CLEAN CONDUIT BEFORE USING OR LAYING. DURING CONSTRUCTION AND AFTER THE DUCT LINE IS COMPLETED, PLUG ENDS OF CONDUITS TO PREVENT WATER WASHING INTO CONDUIT OR MANHOLES, TAKE PARTICULAR CARE TO KEEP CONDUITS CLEAR OF CONCRETE, DIRT AND ANY OTHER SUBSTANCE DURING THE COURSE OF CONSTRUCTION. 3. AFTER DUCT PLACEMENT HAS BEEN COMPLETED, PROOF AND CLEAN DEBRIS FROM EACH DUCT, ITS ENTIRE LENGTH. INSTALL PULL ROPE AND PLACE WATERTIGHT COMPRESSION PLUGS AT BOTH ENDS. ANY CONDUITS CONTAINING FIBER CABLE WILL REQUIRE SIMPLEX COMPRESSION PLUGS SEALING THE CONDUITS AROUND THE CABLE. 4. OUTSIDE INNERDUCT SHALL BE 1-1/4" OPTIC-GUARD NON-METALLIC FLEXIBLE, IN COLOR SUCH AS RED OR ORANGE, WITH PULL ROPES AND PLUGS. EXPOSED INNERDUCT INSIDE OF BUILDINGS SHALL BE PLENUM-RATED. CEMENT CONCRETE PAVEMENT 1. ALL CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED ACCORDING TO THE STANDARD SPECIFICATIONS OF EACH JURISDICTION. ASPHALT CONCRETE PAVEMENT 1. ALL ASPHALT CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED WITH CLASS B ASPHALT CONCRETE ACCORDING TO THE REQUIREMENTS OF EACH JURISDICTION. GRAVEL AREAS 1. ALL GRAVEL AREAS DAMAGED OR REMOVED BY THIS WORK SHALL BE REPLACED WITH CRUSHED SURFACING TOP COURSE IN ACCORDANCE WITH THE REQUIREMENTS OF EACH JURISDICTION. SITE RESTORATION 1. ALL DISTURBED OR DAMAGED AREAS SHALL BE RESTORED TO A CONDITION EQUAL TO, OR BETTER THAN, THAT WHICH EXISTED PRIOR TO PLACEMENT OF THE CONDUIT AND STRUCTURES. 2. VEGETATION REMOVED FOR THIS WORK SHALL BE REPLACED WITH IN-KIND PLANT MATERIAL AND SHALL BE PROPERLY PLANTED AND WATERED IN TO ENSURE ITS SURVIVAL. 3. SITE RESTORATION SHALL INCLUDE REPLACING EXISTING CABLING AND PULL ROPES IN EXISTING CONDUITS AS THEY EXISTED PRIOR TO CONSTRUCTION. WATER QUALITY 1. CONSTRUCTION ACTIVITIES OCCURRING ADJACENT TO STORM DRAINAGE STRUCTURES SHALL COMPLY WITH THE STATE OF WASHINGTON'S WATER QUALITY STANDARDS 2. THE CONTRACTOR SHALL LIMIT THE USE OF PETROLEUM PRODUCTS ON THE SITE. DIRECTIONAL BORING 1. WHEN BORING ROADWAYS, INSTALL (1) 4" SCHEDULE 40 PVC CONDUIT WITH PULL ROPES AND PLUGS. 2. PROTECT EXISTING UTILITIES -- COORDINATE WITH LOCAL JURISDICTIONS TO POTHOLE AS REQUIRED TO LOCATE EXISTING UTILITIES. FIRE PROTECTION 1. ALL INSTALLED BACKBOARDS SHALL BE PAINTED WITH FIRE-RESISTANT PAINT. 2. ALL FIRE SEALED DUCT ENDS AND CORES SHALL BE 2 HOUR FIRE-RATED. ALL FIRE SEAL IN EXISTING LOCATIONS SHALL BE REPAIRED OR REPLACED UPON DUCT OR CABLE PLACEMENT. AERIAL INSTALLATION 1. ALL AERIAL CONSTRUCTION IS TO BE PERFORMED TO INDUSTRY ACCEPTABLE STANDARDS. 2. ALL NEW AERIAL (AND EXISTING) CABLE HEIGHTS OF ATTACHMENT TO BE DOCUMENTED AT TIME OF CONSTRUCTION. 3. 6.35 MM STRAND TO BE USED WITH STANDARD 1/4" POLE LINE HARDWARE UNLESS OTHERWISE SPECIFIED. BOND STRAND TO POWER MAIN WHERE APPLICABLE. 4. ALL ANCHORS TO BE USED WILL BE 3/4" SCREW TYPE. 5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN AND FOLLOW ALL NESC CODES ALONG WITH APPLICABLE LOCAL AND REGIONAL GOVERNING AUTHORITIES. ANY DISCREPANCIES BETWEEN THESE AUTHORITIES AND OR THE CONSTRUCTION PERMITS IS TO BE VALIDATED WITH THE DESIGNER OR ENGINEER PRIOR TO CONSTRUCTION. OF DATE REVISION BY QC CANNON COMPANIES 0000511111K20-YELM SD DC MOVE 401 COATES AVE NW YELM, WA 98597 GENERAL NOTES 3 6 12/17/2020 AB AF COMCAST UTILITY POLE RISER - STANDARD DETAIL (1) 10' PVC CONDUIT SECTIONS 15" HDG POLE BRACKET W/ PIPE CLAMP (B2017 BY POWER-STRUT OR EQUAL) 4" MIN OFFSET FROM POLE.22' (TYP)(1) 10' PVC CONDUIT SECTIONS EXISTING SURFACE24' (TYP)PROPOSED CABLE EXISTING AERIAL POWER EXISTING UTILITY POLEVARIES 2 #RISER PLACEMENT STANDARD DETAIL LOCATION 1 CONDUIT UP TO 2 CONDUITS STANDOFF BRACKET 15" MIN LENGTH ℄ ℄ DIRECTION OF VEHICULAR TRAFFIC PLAN VIEW LOCATION 2 LOCATION 4 LOCATION 3 CONDUIT CLAMP 5" MIN 1 TRENCH - SOFT SURFACE STANDARD DETAIL3 TRENCH - HARD SURFACE STANDARD DETAIL4 WSDOT TRENCH CROSS SECTION STANDARD DETAIL5 OF DATE REVISION BY QC CANNON COMPANIES 0000511111K20-YELM SD DC MOVE 401 COATES AVE NW YELM, WA 98597 DETAILS 4 6 12/17/2020 AB AF COMCAST 210 104 212 313 311 305 301 202 108 211 205 NW J E F F E R S O N A V ESW RICE ST Y E L M A V E S E / S R 5 1 0 NW ED WARDS ST E O P E O P E O P E O P E O P E O P EOP EOP EOPEOPEOP EOP EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOP EOP EOPE O P E O P E O P E O P E O P E O P FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOPEOPEOPFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLEOPEOPEOPEOPEOP1 0 3 ' 2 3 4 ' 1 8 6 ' R O W R O W R OW R O W R O W R O W R OW R OW R OW R O W R O W R OW R O W ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW R O W R O W R O W R OW R OW V35'145'146'156'10'EOPEOPEOPEOPEOP1 2 3 5 6 7 4 NW ED WARDS ST E O P E O P EOPEOPEOPE O P E O P E O P E O P E O P E O P EOPE O P E O P R O W R O W R OW R O W R O W R O W R OW R O W R O W R O W R O W R OW ROWROWROWROWROWROWROWROWROWROW ROW ROW ROW ROW ROW ROWROWROWR O W R OW R OW R O W R O W R OW R O W R O W ROWROWROW R OW ROWROWROWROWROWROWROWROW ROW ROW R OW R OW R OW R OW R OW R OW ROW R OW ROWROWROWROWROW ROW ROW R O W R O W ROWROWROWROWROW ROW ROWROWFLFLFLFLFLFLFLFLFLFLFLFLR 25' OF DATE REVISION BY QC CANNON COMPANIES 0000511111K20-YELM SD DC MOVE 401 COATES AVE NW YELM, WA 98597 DESIGN 5 6 12/17/2020 AB AF COMCAST N CONSTRUCTION NOTES 1.TIE INTO SPLICE CASE SP.WATF.0142 WITH (1) 96CT FIBER & LEAVE COIL 2.OVERLASH (1) 96CT FIBER ON EXISTING AERIAL STRAND 3.PLACE TRANSITION CASE AND TRANSITION INTO 24CT FIBER & LEAVE COIL 4.OVERLASH (1) 24CT FIBER ON EXISTING AERIAL STRAND 5.PLACE (1) 4" RISER AND PULL (1) 24CT FIBER THROUGH 6.TRENCH (1) 4" CONDUIT AND PULL (1) 24CT FIBER TO GC PLACED VAULT 7.PROOF & PULL (1) 24CT FIBER THROUGH GC PLACED 4" CONDUIT 302 310 204 206 206 404 106 213 210 402 NW S T E V E N S A V E V A N T R U M P S T S E NW ED WARDS STEOP EOPEOP EOP EOP EOPEOPEOPEOP EOPEOPROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW 580'FL FL F L FL F L F L F L FL FL FL F L F L F L FL FL F L F L F L F LEOPEOPE O P E O P E O P E O P E O P E O P E O P E O P E O P EOPEOPEOPEOPEOPEOPEOP EOPE O P E O P E O PEOPEOPEOPEOP EOPEOPE O P E O P E O P E O P E O P E O PEOPEOPEOPV NW ED WARDS STROW R O W R O W R OW R O WROWROWROW ROW ROW ROW ROW R O W R O W R O W R OW R O W R O W R O W R O W R OW R O W R O W R O W R OW R O W R O W R O W R O W R O W R O W ROW ROW ROW ROWROWROWROWR OW R O W ROWROWROWROWROWROWROWROW ROW ROW ROW ROW ROWR O W R O W R OW R O W R O W R O W R OW R OW R O W R O W R OW R O W R O W R O W R OW R O W R O WNW EDWARDS STF L F L F L FL FL FL F L F L F L F L F L FL FL FL F L FL F L F L F L F L FL FL FL F L FL F L F L F L F L F L FL E O P E O P E O P E O P E O PEOPEOPEOP OF DATE REVISION BY QC CANNON COMPANIES 0000511111K20-YELM SD DC MOVE 401 COATES AVE NW YELM, WA 98597 DESIGN 6 6 12/17/2020 AB AF COMCAST N CONSTRUCTION NOTES 1.TIE INTO SPLICE CASE SP.WATF.0142 WITH (1) 96CT FIBER & LEAVE COIL 2.OVERLASH (1) 96CT FIBER ON EXISTING AERIAL STRAND 3.PLACE TRANSITION CASE AND TRANSITION INTO 24CT FIBER & LEAVE COIL 4.OVERLASH (1) 24CT FIBER ON EXISTING AERIAL STRAND 5.PLACE (1) 4" RISER AND PULL (1) 24CT FIBER THROUGH 6.TRENCH (1) 4" CONDUIT AND PULL (1) 24CT FIBER TO GC PLACED VAULT 7.PROOF & PULL (1) 24CT FIBER THROUGH GC PLACED 4" CONDUIT 7