Building Plans; < 5 OR MORE ; MAIN FLOOR PLAN 1/4"=1'-O" COPYRIGHT 2015 Landmark Design Inc. ALL RIGHTS RESERVED MAIN FLOOR: 1255 0.PT 6ARA6E : 55 1 SQ .PT FRONT PORCH: 5di 50.PT REAR PATIO: 86 0.PT AGER AT NON- ERVICE 604.9 GENERAL NOTES: 1. ALL WORK TO BE IN CONFORMANCE WITH 2018 IRC. 2. VENT ALL EXHAUST FANS, DRYER VENTS AND RANGES TO OUTSIDES. 3. VENT WATER HEATER PRESSURE RELIEF VALVES TO OUTSIDE. 4. PROVIDE FIRE BLOCKING AT ALL PLUMBING AND MECHANICAL PENETRATIONS. 5. ALL SHOWER WALLS TO BE WATERPROOF t0 MINIMUM -12' ABOVE DRAIN. 6. SHOWERHEADS E KITCHEN FAUCET TO BE LIMITED t0 MAXIMUM L-15 G.P.M. FLOW. ALL OTHER LAVATORY FAUCETS TO BE LIMITED TO MAXIMUM 1.0 G.PM FLOW. -1. ALL GLAZING WITHIN 60' ABOVE DRAIN INLET t0 BE SAFETY GLASS. 6. ALL GLAZING WITHIN 24' OF DOOR OR WITHIN 18' OF FLOOR TO BE SAFETY GLASS 9. SMOKE ALARMS - t0 BE INSTALLED PER SEC 83143 IN THE FOLLOWING LOCATIONS: IN EACH SLEEPING ROOMS, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS, AND ALARMS TO BE INSTALLED NOT LESS THAN 3 FT. HORIZONTALLY FROM A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER ALARMS TO BE INTERCONNECTED IN SUCH A MANNER THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. S.D. =SMOKE ALARM -CARBON MONOXIDE COMBO. G.M. 10. PROVIDE CARBON MONOXIDE ALARMS PER SEC. 8315 AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED ON EACH FLOOR d OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. PER 2018 IRC E WA. STATE AMENDMENTS SEC 8315. 11. INSULATE ALL WATER PIPES TO MINIMUM R-3 PER WSEC 8403.53. 12. ALL DUCTS t EXHAUST DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-6 PER WSEC R4033.1. DUCTS WITHIN A CONCRETE SLAB OR IN THE GROUND SHALL BE INSULATED TO R-10 WITH INSULATION DESIGNED TO BE USED BELOW GRADE. 13. EXHAUST AIR SHALL NOT BE DIRECTED ONTO WALKWAYS. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. PER 8303.52. 14. GAS PIPING IS t0 BE PROTECTED PER G24151. WHERE PIPING IS INSTALLED THROUGH HOLES OR NOTCHES IN FRAMING MEMBERS AND THE PIPING 18 LOCATED LESS THAN 1-1/2 INCHES FROM THE FRAMING MEMBER FACE TO WHICH WALL, CEILING OR FLOOR MEMBRANES WILL BE ATTACHED, THE PIPE SHALL BE PROTECTED BY SHIELD PLATES THAT COVER THE WIDTH OF THE PIPE AND THE FRAMING MEMBER AND THAT EXTEND NOT LESS THAN 4 INCHES t0 EACH SIDE OF THE FRAMING MEMBER WHERE THE FRAMING MEMBER THAT THE PIPING PASSES THROUGH IS A BOTTOM PLATE, BOTTOM TRACK, TOP PLATE OR TOP TRACK, THE SHIELD PLATES SHALL COVER THE FRAMING MEMBER AND EXTEND NOT LESS THAN 4 INCHES ABOVE THE BOTTOM FRAMING MEMBER AND NOT LESS THAN 4 INCHES BELOW THE TOP FRAMING MEMBER 15. ATTIC t CRAWL ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT t0 THE INSULATION ON THE SURROUNDING SURFACES 16. WHOLE HOUSE VENTILATION 24 HR TIMER, READILY ACCESSIBLE E WITH LABEL AFFIXED TO CONTROL THAT READS 'WHOLE HOUSE VENTILATION' (SEE OPERATING INSTRUCTIONS) 11. DRYER DUCT SPECIFIED LENGTH PER SEC 1'11502.4.5.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET(10.668mm) FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH THE TABLE 1" 11502.4.5.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. 18. CAVITIES WITHIN CORNERS AND HEADERS OF FRAME WALLS SHALL BE INSULATED BY COMPLETELY FILLING THE CAVITY WITH A MATERIAL HAVING A THERMAL RESISTANCE OF R-3 PER INCH MINIMUM PER 2018 WSEC TABLE R402A.1.1. 19. STUDS SHALL BE CONTINUOUS FROM THE SOLE PLATE TO A SUPPORT AT THE TOP PLATE(DBL. TOP PLATE OR BEAM/HEADER) PER SEC. R6023(TWO-STORY/ BALLOON FRAME WALLS) WHOLE HOUSE VENTILATION: *REFER TO SHEET N-2 TABLE 1505.43(1) 4 1505.43(2) FOR FAN SIZING AND RUN TIMES FURNACE TO HAVE A DUCT FOR OUTSIDE AIR, MOTORIZED DAMPER WITH TIMER AND CONTROLS ARE t0 BE ADDED FOR THE REQUIRED FRESH AIR EXCHANGE. UTILITY ROOM NOTES/MAKE UP Al PER IRC G2439 1. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION AND THE EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS 35 FT., THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT OF THE EXHAUST DUCT CONNECTION PER G243131B. 2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED WITH MAKE UP AIR WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR MEANS PER G243SB. L - MMT - � = 100 SQ INCH TRANSFER GRILL 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. PLAN NO: L1 -1255-2R DATE: 3-28-23 ON 10'-10' 2'-�' 12'-9' 4'-01 5'-4' 6'-2' 5/0X5/0 XO 6/0X /0 XO DECO_ COL EGRESS I EGRESS I ® 11 ' T I P. B.P. I BEDROOM 2 MASTER I I z' BEDROOM e 110V i 9' CLG, lO O I I 4'-2' S.D. 8D. Ot I I I I 6 I I I I I I 7D ---------- N 1 N - - - - - - - - - - - - - I . �;� 0 MSTR BATH 2 56 1 i 9' CLG. 3 X Q I N I I �; _ -- �� 50 CFM s GYRD 4 51 Q 3 11'-8' PATIO r O GONG. 110V O X 0 W SD• in 1 9 21-31 03 tu BEDROOM 3 0 LIN O 0 e O 0 BATH 50 CFM33 9' CLG. EF. i I 0 IGH C.O X 10'-10' 3'-9' 11'-4' 4'-0' 0 0 61 ;n D I N I N6 ROOM 9' CEILING 0 cn 'n `4 X 0 I e I 6REAT e -;5i 8' w ROOM"� 'r 01 0 I1 11.1 9' CEILING dp EATING BAR OW �. DIRECT VENT NATURAL GAS X METAL FIREPLACE INSTALL 0 MF PER R SPECS. PROVIDE SINK ' X 6SQ IN. OUTSIDE AIR KITCHEN TGHEN x 61 LL Q VAULTED 0 10EC FM m in REFER X ------ I I � I I LOOT I I L ------J O, r SCEP r M r 2' 0' 3'-6' 1 = 4'-8' 19'-0' FU��j 1110 MAXI 13/81 MIN. SOLID CORE WALL MOUNTED GAS BTU/HR SELF CLOSING DOOR HOT WATER SYSTEM MIN. 20,059 o WOOD,STEEL (ENERGY FACTOR=0.91) - - OR 20 MIN. TED c VEHICLE IMPACT PANASONIC 0 BARRIER WHISPER ENTRY - QUIET ONT INUOU 9' CEILING EXHAUSTT GARAGE 0 AN OR O USE 1/2' GWB ON ALL WARM AND EQUAL D STFUCTURAL WALLS. (1) LAYER 5/6' TYPE B 45 CFM ® 'X' ON CEILINGS. WRAP ALL EXPOSED POSTS ' W.HF. AND BEAMS IN 1/2' GWB 6' W UTI L.2 NO DUCT OPENINGS +EV X4/ SH 9' CEILING IN GARAGE. DUCTS THROUGH CLG OR GO ERE WALL COMMON TO HOUSE, 2/Ox /0 SH PORCH MIN. 26 GAGE STEEL. 61 � i IGONG. 0 -------------------------- ------- --- -- HEAT DETECTOR INTERCONNECTED 0 PER 31423 cn 12/0x8/0 0.14. DOOR BLUE 18 AWG TR LANDING AT 'EXIT' DOOR 2'-3' 2'-3' 1'-10' 1'-4' WIRE REQUIRED 4'- 6' NOT TO BE LOWER THAN 3'-3' 3'-3' 3'-2' 7'-11' 1'-11, METAL WATER PIPING PER 8 UPC 1S INCHES FROM TOP OF THRESHOLD. (83113.1) 6'-6' 1'-8' 15'-10' 301-01 MAIN FLOOR PLAN 1/4"=1'-O" COPYRIGHT 2015 Landmark Design Inc. ALL RIGHTS RESERVED MAIN FLOOR: 1255 0.PT 6ARA6E : 55 1 SQ .PT FRONT PORCH: 5di 50.PT REAR PATIO: 86 0.PT AGER AT NON- ERVICE 604.9 GENERAL NOTES: 1. ALL WORK TO BE IN CONFORMANCE WITH 2018 IRC. 2. VENT ALL EXHAUST FANS, DRYER VENTS AND RANGES TO OUTSIDES. 3. VENT WATER HEATER PRESSURE RELIEF VALVES TO OUTSIDE. 4. PROVIDE FIRE BLOCKING AT ALL PLUMBING AND MECHANICAL PENETRATIONS. 5. ALL SHOWER WALLS TO BE WATERPROOF t0 MINIMUM -12' ABOVE DRAIN. 6. SHOWERHEADS E KITCHEN FAUCET TO BE LIMITED t0 MAXIMUM L-15 G.P.M. FLOW. ALL OTHER LAVATORY FAUCETS TO BE LIMITED TO MAXIMUM 1.0 G.PM FLOW. -1. ALL GLAZING WITHIN 60' ABOVE DRAIN INLET t0 BE SAFETY GLASS. 6. ALL GLAZING WITHIN 24' OF DOOR OR WITHIN 18' OF FLOOR TO BE SAFETY GLASS 9. SMOKE ALARMS - t0 BE INSTALLED PER SEC 83143 IN THE FOLLOWING LOCATIONS: IN EACH SLEEPING ROOMS, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS, AND ALARMS TO BE INSTALLED NOT LESS THAN 3 FT. HORIZONTALLY FROM A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER ALARMS TO BE INTERCONNECTED IN SUCH A MANNER THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. S.D. =SMOKE ALARM -CARBON MONOXIDE COMBO. G.M. 10. PROVIDE CARBON MONOXIDE ALARMS PER SEC. 8315 AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED ON EACH FLOOR d OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. PER 2018 IRC E WA. STATE AMENDMENTS SEC 8315. 11. INSULATE ALL WATER PIPES TO MINIMUM R-3 PER WSEC 8403.53. 12. ALL DUCTS t EXHAUST DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-6 PER WSEC R4033.1. DUCTS WITHIN A CONCRETE SLAB OR IN THE GROUND SHALL BE INSULATED TO R-10 WITH INSULATION DESIGNED TO BE USED BELOW GRADE. 13. EXHAUST AIR SHALL NOT BE DIRECTED ONTO WALKWAYS. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. PER 8303.52. 14. GAS PIPING IS t0 BE PROTECTED PER G24151. WHERE PIPING IS INSTALLED THROUGH HOLES OR NOTCHES IN FRAMING MEMBERS AND THE PIPING 18 LOCATED LESS THAN 1-1/2 INCHES FROM THE FRAMING MEMBER FACE TO WHICH WALL, CEILING OR FLOOR MEMBRANES WILL BE ATTACHED, THE PIPE SHALL BE PROTECTED BY SHIELD PLATES THAT COVER THE WIDTH OF THE PIPE AND THE FRAMING MEMBER AND THAT EXTEND NOT LESS THAN 4 INCHES t0 EACH SIDE OF THE FRAMING MEMBER WHERE THE FRAMING MEMBER THAT THE PIPING PASSES THROUGH IS A BOTTOM PLATE, BOTTOM TRACK, TOP PLATE OR TOP TRACK, THE SHIELD PLATES SHALL COVER THE FRAMING MEMBER AND EXTEND NOT LESS THAN 4 INCHES ABOVE THE BOTTOM FRAMING MEMBER AND NOT LESS THAN 4 INCHES BELOW THE TOP FRAMING MEMBER 15. ATTIC t CRAWL ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT t0 THE INSULATION ON THE SURROUNDING SURFACES 16. WHOLE HOUSE VENTILATION 24 HR TIMER, READILY ACCESSIBLE E WITH LABEL AFFIXED TO CONTROL THAT READS 'WHOLE HOUSE VENTILATION' (SEE OPERATING INSTRUCTIONS) 11. DRYER DUCT SPECIFIED LENGTH PER SEC 1'11502.4.5.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET(10.668mm) FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH THE TABLE 1" 11502.4.5.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. 18. CAVITIES WITHIN CORNERS AND HEADERS OF FRAME WALLS SHALL BE INSULATED BY COMPLETELY FILLING THE CAVITY WITH A MATERIAL HAVING A THERMAL RESISTANCE OF R-3 PER INCH MINIMUM PER 2018 WSEC TABLE R402A.1.1. 19. STUDS SHALL BE CONTINUOUS FROM THE SOLE PLATE TO A SUPPORT AT THE TOP PLATE(DBL. TOP PLATE OR BEAM/HEADER) PER SEC. R6023(TWO-STORY/ BALLOON FRAME WALLS) WHOLE HOUSE VENTILATION: *REFER TO SHEET N-2 TABLE 1505.43(1) 4 1505.43(2) FOR FAN SIZING AND RUN TIMES FURNACE TO HAVE A DUCT FOR OUTSIDE AIR, MOTORIZED DAMPER WITH TIMER AND CONTROLS ARE t0 BE ADDED FOR THE REQUIRED FRESH AIR EXCHANGE. UTILITY ROOM NOTES/MAKE UP Al PER IRC G2439 1. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION AND THE EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS 35 FT., THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT OF THE EXHAUST DUCT CONNECTION PER G243131B. 2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED WITH MAKE UP AIR WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR MEANS PER G243SB. L - MMT - � = 100 SQ INCH TRANSFER GRILL 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. PLAN NO: L1 -1255-2R DATE: 3-28-23 ON 4x4 W/ P ON 2 W/(2; 4x6 P.T. W/ EPC2 PBZ 54 FOUNDATION NOTES: I. ALL FOOTINGS t0 BEAR ON FIRM UNDISTURBED SOIL. 2. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. 3. ALL BEAMS TO BE 4x10 DFL 02 ON 4x4 POSTS (4x6 At SPLICES) ON 24' DIA, x 8' CONIC. PADS UNLESS NOTED OTHERWISE. 4. ALL POSTS t0 BE ANCHORED AGAINST LATERAL MOVEMENT. 5. SOLID BLOCK At ALL POINT LOADS FROM ABOVE. 6. FLOOR JOISTS SHOULD BE SUPPORTED LATERALLY AT EACH END AND At EACH SUPPORT, BY SOLID BLOCKING OR BY ANOTHER APPROVED METHOD. -1. PROVIDE MINIMUM 18'-24' CRAWL ACCESS. *CRAWL ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED t0 A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. 6. PROVIDE CRAWL SPACE VENTILATION PER IRC SECTION R408. *FOUNDATION VENTS SHALL BE PLACED SO THAT THE TOP OF THE VENT IS BELOW THE LOWER SURFACE OF THE FLOOR INSULATION. S. INTERIOR GRADE OF CRAWL SPACE SHALL BE SLOPED t0 DRAIN AND INSURE THE REMOVAL OF WATER 10.PREVENT WOOD TO CONC. CONTACT W/CONT. FLASHING OR APPROVE MEMBRANE. 11. / INDICATES 'SIMPSON' HOLDDOWN. 12. aSEE SHEARWALL SCHEDULE FOR A ANCHOR BOLT SIZE E SPACING (SHT SI.0). I/=A 1 t�UUINL-)14 1 1 SIN /=A I /=� I IL; NTS MIN. 2' AIR SPACE 4' CONC. SLAB PREVENT WOOD TO CONC. CONTACT W/ CONT. FLASHING OR APPROVED MEMBRANE STUB 04 BARS INTO CONC. SLAB m IS' O.C. USE 3' x 3' x 1/4' GALVANIZED STEEL SQUARE PLATE WASHERS FOR ALL ANCHOR BOLTS S007- PLAN -ONt. DBL. TOP PLATE Z-10 RIGID INSULATION SHADED AREA) 4X HEADER KING STUD EXTERIOR PLYWOOD TRIMMER HEADER/INSULATION DETAIL 12kI� ROOF VENTILATION CALCUL AT I ONS 4 REQU I REMENTS At LEAST 40% 4 NOT MORE THAN 50% OF REQUIRED VENTS SHALL BE IN UPPER PORTION OF VENTILATED ROOF SPACE (NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT) WITH THE BALANCE OF REQUIRED VENTILATION PROVIDED BY SAVE VENTING. VENTILATION REQUIRED PER SEC. 8806.1 - ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY t0 THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSIONS OF 1/16' INCH MINIMUM AND 1/4' INCH MAXIMUM. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4' SHALL BE PROVIDED WITH CORROSION -RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF 1/16' MINIMUM AND 1/4' MAXIMUM. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM t0 THE REQUIREMENTS OF SECTION 88021. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR MINIMUM VENT AREA PER SEC. 88062 - THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE. VENT AND INSULATION CLEARANCE PER SEC. 88063 - WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR NOT LESS THAN A 1 -INCH SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AND At THE LOCATION OF THE VENT. SEE SHEET N2 FOR ROOF VENTILATION CALCULATIONS AND LOCATIONS ROOF OVERFRAME NOTES: IRC SEC 88023 I. RAFTERS SHALL BE FRAMED t0 2x RIDGE BOARD PER PLAN. RIDGE BOARD SHALL NOT BE LESS IN DEPTH THAN THE CUT END OF THE RAFTER At ALL VALLEYS AND HIPS THERE SHALL BE A 2x VALLEY OR HIP RAFTER AND NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER (FULL COVERAGE At RIDGE, HIPS AND VALLEYS). ROOF FRAMING NOTES: I. ALL HEADERS t0 BE 4x8 DF *2, UNLESS NOTED OTHERWISE. HEADERS AT EXTERIOR WALLS d WARM WALLS TO BE INSULATED W/R-10 RIGID INSULATION. 2. ALL OTHER TRUSSES: • SHALL CARRY MANUFACTURERS STAMP. * SHALL HAVE DESIGN DETAILS AND SPECIFICATIONS ON SITE FOR FRAME INSPECTION. • SHALL BE INSTALLED AND BRACED PER MANUFACTURERS SPECIFICATIONS PER IRC SEC. 502.112 AND 802.103 AS WELL AS THE TRUSS INSTITUTE'S BUILDING COMPONENT SAFETY INFORMATION. 3. NO TRUSS SHALL BE FIELD -MODIFIED WITHOUT PRIOR CONSENT OF THE TRUSS ENGINEER AND THE BUILDING DEPARTMENT. 4. PROVIDE ATTIC ACCESS At A MINIMUM OF 22'x30' PER IRC SEC. R80-11. *ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED t0 A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. 5. PROVIDE ATTIC VENTILATION PER IRC SEC. 8806. ALL FRAMING TO COMPLY WITH IRC SECC RB02. 6. <H I REFER t0 SHEAR WALL SCHEDULE. -1. STUDS SHALL BE CONTINUOUS FROM THE SOLE PLATE t0 A SUPPORT AT THE TOP PLATE (DBL. TOP PLATE OR BEAM/HEADER) PER SEC. 86023 (TWO STORY/BALLOOON FRAME WALLS) I/Tn= I i—On MANUFACTURED TRUSSES MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE ON SITE AT TIME OF INSPECTION, FOR THE INSPECTORS USE AND REFERENCE VENTILATION I I NOTE- I - BEARING OR EXTERIOR WALL CRAWL SPACE VENTILATION FASTENERS FOR TREATED NOTCH 250, BORING 400. TOTAL NET FREE AREA WOOD TO BE HOT -DIPPED - 60% BORING IF DOUBLED < REQ'D 1255/300 = 4.19 SQ. Ft. GALVANIZED, STAINLESS LESS OR EQUAL SUCCESSIVE STUDS. PROVIDE SCREENED VENTS STEEL, SILICONE, BRONZE - NON-BEARING MAXIMUM NOTCH FOR VENTILATION OR COPPER 40%, BORING 60%. VE N T S RE Q E D I I I NCHE O ACE OF STUD N 5/8 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. PLAN NO L1 -1255-2R DATE 3-28-23 F__ 3 2x6 02 OF STUDS m 16' O.C. ATTACH STUDS TO TOP 4 BOTTOM PLATE WITH (3) 16d FRAMING NAILS. CONSTRUCT TOP PLATE OF (2) STUDS INSTALLED HORIZ. AT THE TOP OF THE GYPSUM WALL ASSEMBLY AND THE BOTTOM PLA' A SINGLE STUD. INSTALL 2x6 WOOD STUC HORIZ. AS GROSS -BRACING POSITIONED MID -HEIGHT OF THE WALL. Na' TYPE 'X' GWB APPLIED VERTICALLY W/ HORIZONTAL JOINTS BLOCKED AND FASTENED W/6d CEMENT COATED llka' CUP -HEAD DRYWALL NAILS W40915' SHANK DIA. 4 1/4' HEAD DIA. SPACED 8' O.C. ALONG STUDS 4 PLATES. EXPOSED FASTENER HEADS AND WALLBOARD JOINTS MUST BE TREATED W/(2) COATS OF GYPSUM COMPOUND. A MIN. 2' PAPER, PLASTIC OR FIBERGLASS TAPE MUST BE EMBEDDED IN FIRST LAYER OF COUMPOUND OVER WALLBOARD JOINTS. SOLID TIGHT FITTING TRUSS BLOCKING (SEE DETAIL THIS SHEET FOR SAVE VENTING) 2X8 FASCIA BOARD 3f6' L"FLAMEBLOCKOFIRE-RATED OSB SHEATHING W/IBmm PYROTITE LAMINATE APPLIED TO ONLY ONE FACE OF WOOD PANEL. SHEATHING MUST BE INSTALLED VERTICALLY W/HORIZONTAL JOINTS BLOCKED 4 W/PYROTITE LAMINATE FACING THE OUTSIDE 4 MUST BE ATTACHED TO THE STUDS W/1"I8' 6d COMMON NAILS SPACED 6' O.G. AROUNL PERIMETER 4 12' O.0 IN THE FIELD. 5112' THICK NOMINAL 3 PGF DENSITY UNFACED MINERAL FIBER BATT INSULATION FRICTION FIT BETWEEN THE WOOD STUDS, GROSS -BRACING 4 TOP/BOTTOM PLATES. WEATHER BARRIER FASTENED OVER THE SHEATHING USING SUFFICIENT FASTENERS TO PREVENT AIR POCKETS IN THE WRAP EXTERIOR WALL COVERING: 1. FIBER CEMENT BOARD 2. TI -11 SIDING 3. WOOD FIBER PANEL 4. CEMENT PLASTER (STUCCO) 5. STEEL SIDING DESIGN: NCC -ES REPORT - ESR -1365) WALL TYPE 4.3.4 - 1 HR EXTERIOR WALL ASSEMBLY 1 51 EAVES E WALL WITHIN 5'-0" OF PROPERTY LINE PER IRC 302 E TABLE 8302.1 2x SCREENED EAVE VENT BLOCKS W/(4) 21/9' HOLES EACH - PROVIDE APPROVED INSULATION BAFFLE TO ENSURE 1' MIN. AIR SPACE. -xa ARM 50ARD No TWO$ IOLD END TRUSS IN 3i(e" PROM PAGE OF WALL) (a" TYPE X 6105 /I6" LP PL.AMEBL.00K XTERIOR WALL COVERING: I. P15ER GEMENT BOARD 2. TI -II SIDING 3. WOOD PISER PANEL 4. GEMENT PLASTER (STUCCO) 5. STEEL SIDING 2X6 WALL STUD THICKNE99:2-1/6" (PIRW APPROX. MOW: IPSP (PIRE) PIKE TEST: UL RI319, 9-12-9b UL 1 16N U55& GABLE END P I REWALL METAL L LESS THAN WTO THE PROPERTY LINE GA FILE NO. AF 3640 (GENERIG I HOUR) ONE LAYER Sia' TYPE X GWB APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF MIN 2X3 STUDS, TURNED FLATWISE, 24' O.G. WITH 6d CEMENT -COATED NAILS, 1-1ia' LONG, 0.0915 SHANK, 1/4' HEADS, I' O.C. HORIZONTAL JOINTS STAGGERED NOT LESS THAN 12' ON OPPOSITE SIDED. NO SCALE HOUR FIRS -RESISTIVE DETAILS oL 000 ATTIC SPACE MANUF TRUSSES 24'O.C. SEE ROOF FRAMING PLAN PINING FLOOR CONSTRUCTION: 3/4' T4G PLYWOOD SUB-FLR GLUED 4 NAILED TO (SEE FRAMING PLAN FOR SIZE AND SPACING) CRAWLSPACE 6 MIL VISQUEEN VAPOR BARRIER THROUGHOUT CRAWLSPACE. LAP SPLICES 12' MIN. W1 IN 3(o" MIN. 6x6 PT POST No' TYPE 'X' GWB SIDING OR TRIM PER PLAN POST DETAIL FOR STRUCTURES LESS THAN 5' FROM PROPERTY LINE R-461 INSULATION GREAT ROOM H16H DENSITY R-38 INSULATION BUILDING SECTION 5/a II= 1 -oil AF50 ROOF VENTS (50 SQ. IN. NET FREE AREA) SOLID TIGHT FITTING TRUSS BLOCKING 2x8 FASCIA BOARD 2x STUDS PER PLAN SHEATHING EXTERIOR WALL COVERING PER PLAN EAVES WITHIN 5'-0' OF PROPERTY LINE PER IRC 302 4 TABLE 8302.1 ATTIC VENTILATION AT LEAST 40% 4 NOT MORE THAN 50% OF REQUIRED VENTS SHALL BE IN UPPER PORTION OF VENTILATED ROOF SPACE (NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT) WITH THE BALANCE OF REQUIRED VENTILATION PROVIDED BY SAVE VENTING. COMPOSITION ROOF W/ 30* INTERWOVEN FELT ON 1/2' 24/0 PLYWOOD SHEATHING ALL ROOF FLASHING TO BE MIN. 26 GA GALV. STEEL. ROOF DRIP EDGES PER SEC. 89052.8.5 PROVIDE DRIP EDGE AT EAVES 4 GABLES W/ A MIN. 2' OVERLAP. TYPICAL EXTERIOR WALL (2) 2x6 TOP E 2x6 STUDS O IVO.C. 1/2' SHT'G (APA RATED 24/0) AIR BARRIER EXTERIOR SIDING PER ELEVATION R-21 INSULATION W/ CONT. VAPOR BARRIER (WARM SIDE) STUD NOTCHING AND BORING - BEARING OR EXTERIOR WALL NOTCH 25%, BORING 40%. - 60% BORING IF DOUBLED 4 LESS OR EQUAL SUCCESSIVE STUDS. - NON-BEARING MAXIMUM NOTCH 40%, BORING 60%. - HOLES NO CLOSER THAN 5/8 INCH TO FACE OF STUD. FIRE BLOCKING AND DRAFTSTOPPING PER SEC. 302.11 4 302.12 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: A. VERTICALLY AT THE CEILING 4 FLOOR LEVELS B. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10'-0' 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. 3. IN CONCEALED SPACES AT STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SEC. 8302.1 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION. 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. PLAN NO L1-1255-2R DATE 3-28-23 v MAIN FLOOR ELECTRICAL PLAN 1/4"=1'-O" ELECTRICAL KEY OVERHEAD CAN OUTLET DUPLEX OUTLET 220V OUTLET COMBO. EXT. FAN (VTOS) t LIGHT COM50 SMOKE ALARM- CAR50N MONO. DET. o 110 V W/ 5ATTERY C BACKUP GABLE T.V. JACK PHONE UNDER COUNTER `� MC LIGHTS CCAS OUTLET t HOSE 5155 EXT. FAN VTOS HEAT DETECTOR INTERCONNECTED PER 31423 (GARAGE) EV CHARGER (ELECTRIC VEHICLE) ONE PER DWELLING PER SEC 8335 IRC SMOKE DETECTOR 110 VOLT PER 314.3 +E V 110V S.D. 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. PLAN NO: L1 -1255-2R DATE 3-26-23 ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION, WITH WASHINGTON STATE AMENDMENTS. DESIGN LOADS: ROOF LIVE LOAD 25 PSF (SNOW) DEAD LOAD 15 PSF FLOOR LIVE LOAD 40 PSF (RESIDENTIAL) 60 PSF (DECKS) DEAD LOAD 10 PSF WIND BASIC WIND SPEED 110 MPH (3 SECOND GUST, ULTIMATE LOAD) RISK CATEGORY 11, EXPOSURE B, K A = 1.0 SEISMIC EQUIVALENT LATERAL FORCE PROCEDURE BEARING WALL SYSTEM (LIGHT -FRAMED WALLS) SITE CLASS: D SEISMIC DESIGN CATAGORY: D $s = 1.5 - IBC FIGURE 1613.311) SDs = 1.0, 1E = 1.0, R=6.5 Cs = 0.154 INSPECTIONS: NO SPECIAL INSPECTIONS ARE REQUIRED. NOTIFY THE BUILDING DEPARTMENT FOR INSPECTIONS REQUIRED BY LOCAL ORDINANCE. ALL PREPARED SOIL BEARING SURFACES SHALL BE INSPECTED BY A SOILS ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL. FOUNDATIONS: PLACE FOOTINGS ON NATIVE OR COMPACTED SOIL WITH 1,500 PSF BEARING CAPACITY (ASSUMED). BOTTOM OF EXTERIOR FOOTINGS SHALL BE MINIMUM 1'-6" BELOW OUTSIDE FINISHED GRADE. BACKFILL WALLS WITH A WELL DRAINING MATERIAL FREE OF ORGANIC OBJECTS OR DEBRIS. CONCRETE: THE SELECTION OF MATERIALS FOR AND THE MIXING AND PLACING OF ALL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, 2018 EDITION. MATERIALS SHALL BE PROPORTIONED TO PRODUCE A DENSE, WORKABLE MIX HAVING A MAXIMUM SLUMP OF 4 INCHES WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER USE MINIMUM F'c = 3,000 PSI WITH 5.5 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A MAXIMUM OF 52 GALLONS OF WATER PER 94 LB SACK OF CEMENT. ALL CONCRETE SHALL CONTAIN AN AIR ENTRAINING AGENT. THE AMOUNT OF ENTRAINED AIR SHALL BE 41/251. ±1.551. BY VOLUME. MAXIMUM SIZE OF AGGREGATE IS 11/2 ". ALL CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR EXPANSION JOINTS UNLESS SHOWN OTHERWISE. CONCRETE PURVEYORS/SUPPLIERS DELIVERY OR BATCH TICKET TO BE ON JOB SITE FOR BUILDING INSPECTOR VERIFICATION. REINFORCING STEEL: ALL REINFORCING STEEL SHALL BE MINIMUM GRADE 60 (Fy = 60,000 PSI) DEFORMED BARS IN ACCORDANCE WITH ASTM SPECIFICATION A-615. LAP ALL SPLICES 32 BAR DIAMETERS OR 1'-6" MINIMUM UNLESS OTHERWISE SHOWN. PROVIDE ELBOW BARS (32 DIA.) TO LAP HORIZONTAL STEEL AT COMERS AND INTERSECTIONS IN FOOTINGS AND WALLS. REINFORCEMENT SHALL BE ACCURATELY PLACED AND ADEQUATELY SUPPORTED BY APPROVED CHAIRS, SPACERS, OR TIES AND SECURED IN PLACE DURING GROUT OR CONCRETE PLACEMENT. MINIMUM CONCRETE COVER FOR REINFORCING STEEL: USE SLAB AND WALL BARS: INTERIOR FACES EXPOSED TO WEATHER OR EARTH FOOTING BARS PROTECTION 11/2 11 11/2" (15 AND SMALLER) 2" (*6 AND LARGER) 311 TIMBER: ALL LUMBER SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: BEAMS DF*2 OR BETTER POSTS DF*2 OR BETTER 2x FRAMING HF*2 OR BETTER ALL 2x TIMBER SHALL BE KILN DRIED. ALL GRADES SHALL CONFORM TO "WWPA GRADING RULES FOR WESTERN LUMBER", LATEST EDITION. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA UI. RE -TREAT ALL CUT ENDS, NOTCHES, AND DRILLED HOLES IN ACCORDANCE WITH AWPA M4. MAINTAIN MINIMUM 6" CLEAR BETWEEN WOOD AND EXPOSED EARTH. MAINTAIN 8" CLEAR BETWEEN EXPOSED EARTH AND NON -TREATED WOOD AT EXTERIOR FOUNDATION WALLS. ALL NAILS SHALL BE GALVANIZED BOX OR COMMON NAILS. FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL IN ACCORDANCE WITH SECTION IBC 2304.10.5. ALL MINIMUM NAILING SHALL BE PER IBC TABLE 2304.10.1 U.N.O. MACHINE BOLTS TO BE A-301. BOLT HEADS AND NUTS BEARING AGAINST WOOD SHALL BE PROVIDED WITH STANDARD CUT WASHERS. MISCELLANEOUS HANGERS TO BE 'SIMPSON' OR ICC APPROVED EQUAL. ALL HANGERS TO BE FASTENED TO WOOD WITH PROPER NAILS AND ALL HOLES SHALL BE NAILED. GLUED LAMINATED WOOD MEMBERS: GLUED LAMINATED WOOD BEAMS (GLB) TO BE IN ACCORDANCE WITH ANSI/AITC STANDARD A190.1, AMERICAN NATIONAL STANDARD FOR STRUCTURAL GLUED LAMINATED TIMBER USE STRESS GRADE COMBINATION 24F -V4 (Fb = 2,400 PSI) FOR SIMPLE SPANS AND 24F -V8 FOR CANTILEVER AND CONTINUOUS SPANS. SIMPLE SPANS SHALL BE CAMBERED ON A 3500' RADIUS UN.O. GLUE SHALL BE CASEIN WITH MOLD INHIBITOR UNLESS OTHERWISE SPECIFIED, SEALER SHALL BE APPLIED TO ENDS OF ALL MEMBERS. BOTTOM LAMINATION TO BE FREE OF UNSOUND KNOTS LARGER THAN 1/2" DIAMETER AITC STAMP AND CERTIFICATION REQUIRED. PREFABRICATED JOISTS: JOISTS SHALL BE AS NOTED ON THE PLANS AND AS MANUFACTURED BY TRUSS JOIST WEYERHAEUSER OR APPROVED EQUIVALENT. JOISTS TO BE ERECTED IN ACCORDANCE WITH THE PLANS AND THE MANUFACTURER'S DRAWINGS AND INSTALLATION INSTRUCTIONS. CONSTRUCTION LOADS BEYOND THE DESIGN LOADS ARE NOT PERMITTED. PROVIDE ERECTION BRACING UNTIL SHEATHING MATERIAL HAS BEEN INSTALLED. PROVIDE SOLID BLOCKING AT CONCENTRATED LOADS FROM ABOVE AND WEB STIFFENERS PER MANUFACTURER'S DIRECTIONS. JOIST HANGERS TO BE SIZED AND PROVIDED BY THE MANUFACTURER OR SUPPLIER LAMINATED VENEER LUMBER (LVL): LAMINATED VENEER LUMBER (LVL) TO BE BY TRUSS JOIST WEYERHAEUSER (MICROLAM - Fb = 2000 PSI, E = 1,900,000 PSI). MATERIAL SHALL BE DESIGNED 4 MANUFACTURED TO THE STANDARDS SET FORTH IN NER-481 OR CCMC REPORT NO. 08615-R. BEARING LENGTH SHALL NOT BE LESS THAN 11/2 ". DO NOT CUT OR NOTCH BEAMS WITHOUT PRIOR APPROVAL OR ENGINEER HEEL CUTS SHALL NOT OVERHANG INSIDE FACE OF SUPPORTING MEMBER. BEARING WALL FRAMING: ALL DOOR AND WINDOW HEADERS NOT CALLED OUT OR OTHERWISE NOTED ON THE PLANS SHALL BE 48 DF2 WITH ONE CRIPPLE AND ONE STUD EACH END FOR OPENINGS 5'-0" OR LESS AND TWO CRIPPLES AND ONE STUD FOR OPENINGS MORE THAN 5'-0" WIDE. STUDS SHALL BE CONTINUOUS FROM SILL PLATE AT FOUNDATON TO TOP PLATE AT ROOF OR CEILING. ALL COLUMNS NOT CALLED OUT ON THE PLANS SHALL BE TWO (2) STUDS. SPIKE LAMINATED COLUMNS TOGETHER WITH 16d S 12" O.C. STAGGERED. STAGGER SPLICES AT TOP PLATES MINIMUM 48" AND NAIL WITH 16d .9 8" O.C. SHEAR WALL& ALL SHEAR WALL SHEATHING NAILING AND ANCHORS SHALL BE AS DETAILED ON THE DRAWINGS AND NOTED IN THE SHEAR WALL SCHEDULE. USE APA RATED SHEATHING (24/1(0) WITH A MINIMUM PANEL EDGE NAILING OF 8d 4v 6" O.C. UNLESS NOTED OTHERWISE. ALL SHEAR WALL NAILING SHALL BE COMMON WIRE OR GALVANIZED BOX NAILS. FASTENERS IN PRESERVATIVE -TREATED WOOD SHALL BE OF NOT -DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL. BLOCK ALL UNSUPPORTED PANEL EDGES. DESIGNATED 3x FRAMING MAY BE (2) 2x MEMBERS FACE -NAILED WITH 16d 6 12" O.C. STAGGERED. ALL HEADERS SHALL HAVE STRAP CONNECTORS TO THE TOP PLATE AT EACH END WHEN THE HEADER INTERRUPTS THE TOP PLATE. USE 'SIMPSON' L5TA24 CONNECTOR U.N.O. FLOOR AND ROOF FRAMING: DIMENSIONAL FRAMING MEMBERS SHALL BE FREE OF SPLITS, CHECKS, AND SNAKES. PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE LENGTH AND ALL AROUND ALL OPENINGS IN FLOORS AND ROOFS U.N.O. PROVIDE SOLID BLOCKING AT RIM JOISTS BELOW CONCENTRATED LOADS FROM ABOVE. APPLY 3/4" RATED SHEATHING (40/20) GLUED AND NAILED TO FLOOR FRAMING MEMBERS WITH Sd COMMON OR GALVANIZED BOX NAILS AT b" O.C. AT ALL SUPPORTED EDGES AND 8d COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT INTERIOR SUPPORTS. APPLY 1/2" RATED SHEATHING (24/1(0) ON ROOF NAILED TO STIFFENERS OR RAFTERS WITH 8d COMMON OR GALVANIZED BOX NAILS AT 6" O.C. AT SUPPORTED EDGES AND ed COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT INTERIOR SUPPORTS. LAY SHEATHING PERPENDICULAR TO FRAMING AND STAGGER PANEL EDGES. FLOOR AND ROOF TRUSSES: TRUSSES TO BE DESIGNED AND SUPPLIED IN ACCORDANCE WITH ANSI/TPI 1-2014. THE TRUSS CALCULATION PACKAGE SHALL BE PREPARED UNDER THE DIRECT SUPERVISION OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. THE TRUSS ENGINEER SHALL ASSUME ALL RESPONSIBILITY FOR THE WORK OF ALL SUBORDINATES INVOLVED IN THE PREPARATION OF THE TRUSS PLACEMENT PLAN AND TRUSS DESIGN DRAWINGS. EACH TRUSS SHALL BE PLANT FABRICATED AND SHALL BEAR THE QUALITY CONTROL STAMP, MANUFACTURER'S NAME, DESIGN LOAD, AND MAXIMUM SPACING. ALL MECHANICAL CONNECTORS SHALL BE ICC APPROVED. LOADS SHALL BE IN ACCORDANCE WITH THE RECOMMENDED DESIGN LOADS AND IBC CHAPTER 16. MANUFACTURER SHALL PROVIDE ALL TRUSS -TO -TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE BUILDING DEPARTMENT FOR APPROVAL AND MAINTAIN DRAWINGS ON SITE FOR INSPECTION. CONTRACTOR TO VERIFY ALL TRUSS LENGTHS PRIOR TO FABRICATION AND INSTALLATION. TRUSSES SHALL BE BRACED TO PREVENT ROTATION AND PROVIDE LATERAL STABILITY IN ACCORDANCE WITH THE CONSTRUCTION DRAWINGS AND INDIVIDUAL TRUSS DRAWINGS. NO TRUSS SHALL BE ALTERED WITHOUT PRIOR WRITTEN CONSENT OF THE TRUSS DESIGNER AND ENGINEER OF RECORD. GENERAL CONSTRUCTION NOTES: ALL CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE (IBC), 2016 EDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND METHODS, TECHNIQUES, AND SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE SPECIFIED WORK THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ALL CONDITIONS AT THE JOB SITE INCLUDING BUILDING AND SITE CONDITIONS BEFORE COMMENCING WORK AND BE RESPONSIBLE FOR SAME. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING DEPARTMENT FOR ALL BUILDING DEPARTMENT REQUIRED INSPECTIONS. DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. THE DETAILS SHOWN ARE TYPICAL AND SHALL BE USED FOR LIKE OR SIMILAR CONDITIONS NOT SHOWN. VARIATIONS AND MODIFICATIONS TO WORK SHOWN ON THE DRAWINGS SHALL NOT BE CARRIED OUT WITHOUT THE WRITTEN PERMISSION FROM THE ARCHITECT OR ENGINEER 5NEAR WALL 5CbEDULE MARK MINIMUM SHEATHING (1) SHEATHING NAILING (1) ANCHOR BOLTS (3) REMARKS (4, 5 ) 1/2" CDX ad I1 6" O.C. 5/8" Is (00" O.C. QaII = 230 PLF 1 OR OSB 1/2" CDX ed t1 4" O.G. 5/811,9 32" O.C. QaII = 350 PLF OR OSB SEE DETAIL 12 / 52.0 FOR CONSTRUCTION REINFORCEMENT MINIMUM NOTES 1) ALL WALLS DESIGNATED" D11 ARE SHEAR WALLS. EXTERIOR WALLS SHALL BE SHEATHED WITH RATED SHEATHING (24/0) AND NAILED AT ALL PANEL EDGES (BLOCKED) PER SCHEDULE. NAILING AT T1-11 PANELS SHALL BE THROUGH EACH EDGE OF EACH PANEL. NAILING AT INTERMEDIATE FRAMING TO BE AT 12" O.C. NAILING NOT CALLED OUT SHALL BE PER IBC TABLE 2304.10.1. NAILING IN PRESERVATIVE TREATED LUMBER SHALL BE STAINLESS STEEL OR OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL PER ASTM A153. 2) HOLDOWNS AND OTHER FRAMING HARDWARE BY SIMPSON STRONG TIE OR ICC APPROVED EQUAL TO BE USED PER PLAN. ENDS OF SHEAR WALLS SHALL USE DOUBLE STUDS MINIMUM. 3) USE MINIMUM OF TWO (2) BOLTS PER SILL PIECE WITH ONE BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 5" FROM EACH END OF EACH PIECE. EMBED BOLTS MINIMUM OF 7 INTO CONCRETE. WASHERS TO BE 3" x 3" x 1/4" PER IBC SECTION 230832 AND OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL IN ACCORDANCE WITH ASTM A153. EDGE OF PLATE WASHER TO EXTEND TO WITHIN 1/2" OF SHEATHED SIDE OF BOTTOM PLATE. 4) ALLOWABLE LOADS ARE PERMITTED TO BE INCREASED 4051. FOR WIND DESIGN IN ACCORDANCE WITH AF4PA SDPWS TABLE 43A. 5) DESIGNATED 3x STUDS MAY BE (2) 2x MEMBERS FACE -NAILED WITH 16d 0 12" O.C. STAGGERED. U STEM WALL a 2 7­ a ° ADD "4 f BAR FOR a STEPS EXCEEDING 2'. all ° ° ° 2 MAX. MAX. LLI,N� L6 J U N m W Q H � W ( 1!_ O W �N 1 CONTINUOUS FTG. I' -m" REINFORCEMENT MINIMUM 1 STEPPED FOOTING DETAIL SI.O SCALE: 34. = 1'-O" rn a� W lbd a 16" O.C. SOLE .p p PLATE NAILING. W 3/4" SUBFLOOR by (3) 8d JOIST -TO -TOP q MSTC40 HOLDOWN. ALIGN PLATE UNA. MAINTAIN WITH EMBEDDED STHD MIN. 111/2" END DISTANCE. TYPE HOLDOWN BELOW. n o �V U SHEATHING 4 NAILING PER PLAN. SPLICE TO OCCUR ON COMMMON MEMBER OR .5 U BLOCKING 2 x 6 STUD a 16" O.C. USE ■ SHEAR ALLS 4 WO DOWNS. 6'-m" bt 2x PT SILL w/ 5/8"4ANCHOR MAX SHEATHING 4 NAILING BOLT 4 3" x 3" x 1/4" WASHER PER PLAN. MATCH WALL AT V -m" O.C. LIAO. 0 ABOVE UN o.(ALT. MASA a 48" O c) 41 FINISH GRADE In STHD TYPE HOLDOWN PER PLAN. -04 BAR a 10" OL. - HORIZ (36" 04 BAR s 16" OAC. - VERT. FINISH GRADE 04 BAR CONTINUOUS (18" MK) 4� ITYP OF 2) r.t � 2 CRIPPLE WALL WITIH BACKFILL FOUNDATION 51.0 SCALE: 34= ■ 1'-O" GOI=YRIGHT 2023, 5EGA ENGINEER5 W U� 0 .. 0 m cc 0 a b a cq 0 cq w w co 0 cq cq JOB 16-00-7 '/z" RATED SHEATHING Sd 6 6" O.C. 2x BLOCKING w/ (3) ad ad a 6 O.C. (LENGTH OF TRUSS) O.C. 6" O.C. TOE -NAIL t0 4x BEAM (4" O.G. a SIM.) ~ z4 SUBFLOOR PER PLAN (2) ad TO JOISTS. RATED SHEATHING ( f&) @ N w STAGGERED SHEATHING JOIST PER PLAN _ PER PLAN. EXTEND OVER 2x VENTED BLOCKING. H1 FRAMING ANCHOR 2x4 wl l8) lbd At m ff EACH TRUSS. USE H10A-2 NOTE: 6� LLO At DBL TRUSS. GABLE END TRUSS. �1 MAXIMUM LATERAL BEAM PLICE. W ad 6" O.C. 1 2x BLOCKING AT 2x4 GUSSET EA (NOT A METAL CAP) LOAD IN EITHER TRUSS, PANEL EDGE SIDE w/ (8)16d U 73 N V 2 3,950 LBS. (ALT. METAL CAP) p N A356 48 O.C. 2x NAILER w/ 16d DBL 2x TOP PLATE. LAP (USE 24" O.C. AT SIM.) 4" O.C. t0 TRUSS 4x4 Pt POST TRUSS PER PLAN SPLICE 4 -0 MIN. � NAIL w/ 2x BRACE PER TRUSS SUPPLIER ++ 2x VENTED BLOCKING. (4x6 AT SPLICE) END NAIL t0 TRUSS � DBL 2x TOP PLATE. LAP SPLICE 16d 6 6" O.C. STAGGERED. OR G 48" O.C. SECURE w/ TRUSS PER PLAN MAB ANCHOR EACH END w/ l2) ad, 4'-0" MIN. � NAIL w/ 16d -9 4" O.C. A34 EACH END. IB STAGGERED. ADD LSTA24 TO (ALT. A34 ANCHOR MIN. WALL SHEATHING AND NAILING SPLICE PER PLAN SHEATHING NAILING LI/z" PLYWOOD (24ii6) wl (2) ROWS TWO SIDES) 12" PER PLAN OR SCHEDULE.J14 PER PLAN OR SHEAR 2x FRAMING PER PLAN. ad 4" O.C. t0 TOP PLATE FTG PER PLAN o MIN. 03 SPLICE TO OCCUR ON COMMON 2x FRAMING PER PLAN. WALL SCHEDULE. (HEADER SIM.) ad 4 O.C. EDGE NAILING > D o a� o MEMBER OR BLOCKING SHEATHING 4 NAILING FINISH GRADE o w PER PLAN\7. w a �o.01 1 TYPICAL ROOF FRAMING CONNECTION 2 ROOF FRAMING GA5LE END 3 INTERIOR 5HEAR WALL TRU55 r4 FLOOR FRAMING AT CRAWL 513ACE cc s2 0 SCALE: I" = I'-0" 52 0 SCALE: I" = I'-0" S2 0 SCALE: P = I'-0" 52 0 SCALE: P = I'-0" o 2x STUD PER PLAN. USE MINIMUM o 2x STUD PER PLAN. USE SHEATHING 4 NAILING •� u U o DBL OR 3x STUD 6 HOEDOWN. PER PLAN OR SCHEDULE DB D � D R I� WALLS AND HOLDOUINS. SEE SHEAR FRAMING 4 SHEATHING PER a 2x Pt SILL w/ ANCHOR BOLI WALL SCHEDULE FOR 3x STUDS. PLAN. SEE PORTAL FRAME 5/s 4 ANCHOR BOLT w/ 3 x 3 x 1/4 0 co 16d � 16 O.C. SOLE � � SHEATHING NAILING 3" x 3" x 1/4" GALV. WASHER SEE PLATE NAI 3/4�� SUBFLOOR PANEL PER PLAN. (12/520) GALVANIZED PLATE WASHER � o JOIST PER PLAN co PER PLAN OR SCHEDULE SCHEDULE FOR SIZE AND SPACING. 2x Pt SILL w/ (2) 2x HAILERS USE 5/s"O 9 60" O.C. U.N.O. 4" SLAB ON GRADE OVER rn a 6" MIN. ° MIN. 6 MIL VAPOR BARRIER a FINISH GRADE OR �3 cQ 12" MAX. SLAB ON G DE ° ° 04 BAR - HORIZONTAL i a ..q = cq SLAB ON GRADE PER PLAN A-4 4 BAR - HORIZONTAL 6" MIN. (NOT 's S.O.G.) OVER 6 MIL VAPOR BARRIER j 2x Pt SILL STHD HOLDOUN a w I'-6" STHD NOLDOUN ° a ON COMPACT BASE. FINISH GRADE 12 MAX• `'ANCHOR BOLI w/ 3"x3x�/4" GALV. PER PLANa i--�--4 PER PLAN 15.0. SIM.)`�� WASHER SEE SCHEDULE FOR SIZE cQMIN, sd #41BAR's 24 O.C. - VERTICAL 4 i$AR 24" O.C. -a a #4 BAR CONI. - TYP. - VERTICAL SPACING. USE 5/s"O �' 60" O.C. MIN. #4 BAR 24" O.G. -VERT. GilI'-6" MIN. O 4'-0" MAX. STHD HOLDOUN (oil �— 6" #4 BAR CONT. 6„ PER PLAN. (8" t1 SIM.) O 8 .. (oil 04 BAR CONT. I' 8 I'-0" s 0:: FOUNDATION AT 5LA5 ON GRADE FOUNDATION AT CRAWL SPACE l FOUNDATION AT OVERHEAD GARAGE DOOR 2.0 SCALE: I I -0 " - " S2 0 SCALE: P = I'-0" 52.0 SCALE: I" = V-0" _ L6TA24 STRAP (FAR SIDE) 16„ 2x TOP PLATE 00 MINIMUM NAIL SHEATHING t0 NDR NDR PER PLAN. EXTEND w/ ad 6 3" O.C. EACH WAY. OVER PANEL t0 KING STUD. (6)16d KING SCUD t0 HEADER �...... . M• 2x KING STUD w/ 2x FASTEN TOP PLATE t0 f CRIPPLE STUD HEADER w/ (2) ROWS } 16d At 3" O.C. : +, 4x BLOCKING s MIDDLE }� 24" IF REQUIRED.00 (� 10'-0" MAX. `!'�:a �; (8'-0" Is SIM) '+ i �•; :i +; /z" RATED SHEATHING (24/0 EXP V. + NAIL w/ (2) ROWS ad 's 3" O.C. AT `! '' PANEL EDGES. (2) 2x CRIPPLE :j ++ +! STUDS. ., .i �.; LH u .! 1 (2) 2x PLATE. (NAIL .! ;` SHT'G t0 EA PLATE) .; A :! TOP OF STEM WALL n W_ ELEV. VARIES I � W STND14 HOEDOWN UNO. 2x PT SILL \(2) 5/8"O ANCHOR BOLT w/ MIN. _7 EMBEDMENT 4 3" x 3" x I/4" GALVANIZED iE WASHER FOUNDATION PER PLAN. MIN. 8" THICK STEM WALL w/ 04 BAR HORIZ. TOP 4 BOTTOM. 12 PORTAL FRAME PANEL 82.0 SCALE: NONE 5 _ o - 01, COPYRIGHT 2023, SEG A ENGINEERS JOS 18-00-1