Loading...
2022.0073 - Floor Truss Layout - B (approved)Truss Connector Total List Manuf Product Qty USP HD412IF 3 USP JUS210-2 1 USP JUS28-2 1 USP JUS46 27 GARAGE 5.5x18 GLB (UP) 5.5x16.5 GLB (UP)3.5x15 PSL (UP)5.5x10.5 GLB (DN) FAU IBC 2018 APPLIED ALTHOUGH EVERY EFFORT HAS BEEN MADE TO AVOID PLUMBING DROPS IN THE PLACEMENT OF TRUSSES ON THIS LAYOUT, THE CONTRACTOR SHOULD VERIFY ALL DRAIN LOCATIONS. FLOOR TRUSSES CAN BE MOVED 1" TO 3" TO AVOID DROPS. B1 B2 B4 B3 B5 B2 B2 B6 F01F02 F03F04F05F05F05F06F07F08F09F09F10F11F11 F11F12F13F13F13F13F14F15F16F17F18 F19F06 F20F09F08JUS28-2 JUS46JUS46JUS46JUS46JUS46HD412IFHD412IFHD412IFJUS46JUS46JUS46JUS46JUS46JUS46 JUS46JUS46JUS46JUS46JUS46JUS46JUS46JUS46JUS46JUS46JUS46JUS46JUS46JUS46JUS46JUS46JUS210-222-06-0019-02-08 12-03-0810-06-0064-06-002-00-003-06-00 17-07-08 21-04-08 15-06-00 4-06-0064-06-0014-10-005-08-00 40-00-00 11-00-0029-00-00 40-00-00 11-05-08 19-06-00 11-00 21-05-009-00-008-07-087-08 14-02-00 2-09-08 6-00-0017-00-005-06-0018-03-0819-09-081-05-08 1-04-04 6-04-00 2-02-004-02-086-02-00 13-04-005-10-0811-10-085-05-00 13-09-08 2-03-00 1-08-00 Sales Rep: Estimate By: Kelly Finelli Customer:Todd Kittelson Sheet Number:1of1Drawing Type: Floor Trusses Soundbuilt NW, LLC Plan: 2470B-2/Gar_Lt Job Name: Date: 7/28/2021 2470B-2 J109400AF Job Number: Loading TC/LL = 25.0 lb TC/DL= 8.0 lb BC/DL= 7.0 lb WIND = 110 mph 'B' Finalized By: Kelly Finelli ** IMPORTANT ** = INDICATES LEFT ENDAddress:,Lacey,WA 98513 Lot: Received by City of Yelm 07/06/2022 4:47:02 PM