Energy Code Worksheet2018 Washington State Energy Code — Residential
EnerRv Code Compliance for All Climate Zones in
These requirements apply to all IRC building types, including detached one- and two-family
dwellings and multiple single-family dwellings (townhouses).
Project Information Contact Information 1
1441
Instructions: This single-family project will use the requirements of the Prescriptive Path below and
incorporate the minimum values listed. Based on the size of the structure, the appropriate number of
additional credits are checked as chosen by the permit applicant.
Provide all information from the following tables as building permit drawings: Table R402.1- Insulation and
Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits.
Authorized Representative Date
All Climate Zones (Table R402.1.1)
R -Value a
U -Factor'
Fenestration U-Factorb
n/a
0.30
Skylight LI -Factor b
n/a
0.50
Glazed Fenestration SHGC b,e
n/a
n/a
Ceiling a
49 i
0.026
Wood Frame Wall s -h
21 int
0.056
Floor
30
0.029
Below Grade Wall `-h
_
10/15/21 int +TB
0.042
Slab ','R -Value & Depth
10, 2 ft
n/a
R -values are minimums. U -factors and SHGC are maximums. When insulation is installed in a cavity that is less
a
than the label or design thickness of the insulation, the compressed R -value of the insulation from Appendix
Table A101.4 shall not be less than the R -value specified in the table.
b
The fenestration U -factor column excludes skylights.
"10/15/21 +5T13" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on
the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at
c
the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity Insulation on
the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB"
means R-5 thermal break between floor slab and basement wall.
d
R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1.
For single rafter- orjoist-vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth
e
extends over the top plate of the exterior wall.
R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter
f
slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic Is used, it shall
meet the requirements for thermal barriers protecting foam plastics.
For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for
9
climate zone 5 of ICC 400.
Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard
h
framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10
insulation.
Prescriptive Palh —Single Family 2018 Washington State Energy Code -R
2018 Washington State Energy Code - Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
[ �SingleFafpily-NN6WAAdi(iti'hi effective %ebruary'1,2021)=
Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel
normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of
credits. To claim this credit, the building permit drawings shall specify the option selected and the
maximum tested building air leakage, and show the qualifying ventilation system and its control sequence
of operation.
1. Small Dwelling Unit: 3 credits
Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area.
Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf.
2. Medium Dwelling Unit: 6 credits
All dwelling units that are not included in #1 or 43
3. Large Dwelling Unit: 7 credits
Dwelling units exceeding 5,000 sf of conditioned floor area
4. Additions less than 500 square feet: 1.5 credits
All other additions shall meet 1-3 above
Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4.
Summary of Table R406.2
Heating
Options
Fuel Normalization Descriptions
Credits - select ONE
heating option
User Notes
1
Combustion heating minimum NAECA'
0.0
Q
2
Heat pump`
1.0
❑
3
Electric resistance heat only - furnace or zonal
-1.0
❑
4
DHP with zonal electric resistance per option 3.4
0.5
❑
5
All other heating systems
-1.0
❑
Energy
Options
p
Energy Credit Option Descriptions
Credits - select ONE
energy option from each
category
1.1
Efficient Building Envelope
0.5
❑
1.2
1.3
Efficient Building Envelope
Efficient Building Envelope
1.0
0.5
❑
Q
1.4
Efficient Building Envelope
1.0
❑
1.5
Efficient Building Envelope
2.0
❑
1.6
Efficient Building Envelope
3.0
❑
1.7
Efficient Building Envelope
0.5
❑
2.1
Air Leakage Control and Efficient Ventilation
0.5
2.2
Air Leakage Control and Efficient Ventilation
1.0
❑
2.3
Air Leakage Control and Efficient Ventilation
1.5
❑
2.4
Air Leakage Control and Efficient Ventilation
2.0
❑
3.1'
High Efficiency HVAC
1.0
❑o
3.2
High Efficiency HVAC
1.0
❑
3.3'
High Efficiency HVAC
1.5
❑
3.4
High Efficiency HVAC
1.5
❑
3.5
High Efficiency HVAC
1.5
❑
3.6'
_
High Efficiency HVAC
2.0
❑
4.1
High Efficiency HVAC Distribution System
0.5
❑
4.2
High Efficiency HVAC Distribution System
1.0
❑
Prescriptive Path -Single Family 2018 Washington State Energy Code -R
2018 Washington State Energy Code — Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Single Fai»lly New &Additions (effeciitie Februaryi, 2021) '`
Summary of Table R406.2 (cont.)
Energy
Options
Energy Credit Option Descriptions (cont.)
Credits - select ONE
energy option from
each category d
User Notes
__
5,V
Efficient Water Heating
0.5
❑
5.2
_ _
Efficient Water Heating
0.5
❑
5.3
Efficient Water Heating
1.0
Fil
5.4
Efficient Water Heating
1.5
❑ _
5.5
Efficient Water Heating
2A
❑
5.6
Efficient Water Heating
2.5
❑
6.1e
Renewable Electric Energy (3 credits max)
1.0
7.1
Appliance Package
0.5
❑
Total Credits
3.0
CLEAR FORM
a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W,
whichever is bigger, may be installed in the dwelling unit.
b. Equipment listed in Table C403.3.2(4) or C403.3.2(5)
c. Equipment listed in Table C403.3.2(1) or C403.3.2(2)
d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may be combined
with options 5.2 through 5.6. See Table 406.3.
e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max.
See the complete Table R406.2 for all requirements and option descriptions.
Prescriptive Palh —Single Family 2018 Washington State Energy Code -R
Size: Washington State
This healing system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA
Manuals J and S. This tool W0 calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads.
complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some
will be calculated for you. If you do not see the selection you need in the drop-down options, please contact the WSU Energy Program at
code@energy.wsu.edu or (360) 956-2042 for assistance.
Heating System Type: Owiomersrnrns OO neat rumn
To see detailed instructions /or each section, place your cursor on the word "Instructions"
Design Temperature
Instructions----- - - - Design Temperature Difference (AT)
�` spatia nay AT=rrdoor(]o degrees)- oumoorne:yn Temp
Area of Duilding
Conditioned Floor Area
Instructions Conditioned Floor Area (sq ft)
Average Ceiling Height
Instructions Average Ceiling Height (ft)
Glazing and Doors
[as true nons —::- y.
Skylights
Instructions
Insulation
X Area =
Attic
879
Instructions
X Area
No selection
Building Design Heat Load 15,370
Btu/Hour
Afrleakage + envelope heat loss
U- Factor
X Area
0.056
1,580
Single Rafter or Joist
Vauited Callings
0.025
Instructions
U- Factor
��
No selection
Select 0. -Value
0
Above Grade Walls
(:ee Figure r)
F- Factor
Instructions
'`"
•r
rt-st mcermee,ate
F- Factor
X Length
No selection
Floors
0
Instruction
R-38 -
—
Below Grade Walls
(see Figured
Instructions
Se1M
R-talue
Slab Below Grade
(see Figure d
Instructions
`—
Select COMbonLq
Slab on Grade (see
�xz
Figure it
Instructions
`selects
-Value
Location of Ducts
Instructions
cona�uonm space
Figure 1.
abo�ecr:ae
rF-,,,�....,.v, -mss...,...•.,
Conditioned Volume
8.0 11,528
U -Factor X Area - UA
0.280 1:3 52.64
U -Factor
X Area UA
-
0.50 0
U•Factor
X Area =
0.026
879
U- Factor
X Area
No selection
Building Design Heat Load 15,370
Btu/Hour
Afrleakage + envelope heat loss
U- Factor
X Area
0.056
1,580
U•Factor
X Area
0.025
$19.
U- Factor
X Area
No selection
0
F- Factor
X Le
No selection
F- Factor
X Length
No selection
0
F7Rii.Slp_1
Duct leakage Coefficient
1.00
182.89
:YO
Envelope Heal Load 9,144
Btu/Hour
Sum o/ UAx AT
Air leakage Heat Load 6,225
e(u /Hour
Vofumex 0.6x ATx0.018
Building Design Heat Load 15,370
Btu/Hour
Afrleakage + envelope heat loss
Building and Duct Heal Load 15,370
Btu/ Hour
Ducts in unconditioned space., sum o1 building heat loss x 1.10
Ducis in conditioned space: sum of building heat loss x 1
Maximum Heat Equipment Output 195212
Btu / Hour
Bi flame and duct heat loss x 1.40 /or forced air furnace
Building and duct heat loss x 1.25 /or heat pump
(Ol/df/l3J
Window, Skylight and Door Schedule
Project Information
1441
Ref. U -factor
Exempt Swinging Door (24 sq. ft. max.)
Exempt Glazed Fenestration (15 sq. ft. max.)
Vertical Fenestration (Windows and doors)
Component
Contact Information
4.00
0.0
0.00
24.0
:,..
6.72
¢
9.0
2.52
8.0
2.24
16.0
4.48
20.0
5.60
4.0
1.12
16.0
4.48
16.0
4.48
6.0
1.68
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
20.0
4.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
Ref. U -factor
Exempt Swinging Door (24 sq. ft. max.)
Exempt Glazed Fenestration (15 sq. ft. max.)
Vertical Fenestration (Windows and doors)
Component
Contact Information
Width Height
Qt. Feet Inch Feet Inch
Width Height
Qt. Feet Inch Feet Inch
Area UA
20.0
4.00
0.0
0.00
24.0
:,..
6.72
¢
9.0
2.52
8.0
2.24
16.0
4.48
Width Height
Qt. Feet Inch Feet Inch
Width Height
Qt. Feet Inch Feet Inch
Area UA
20.0
4.00
0.0
0.00
Area UA
5.0
1.40
24.0
6.72
24.0
6.72
9.0
2.52
8.0
2.24
16.0
4.48
20.0
5.60
4.0
1.12
16.0
4.48
16.0
4.48
6.0
1.68
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
20.0
4.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
Sum of Vertical Fenestration Area and UA
Vertical Fenestration Area Weighted U = UA/Area
Overhead Glazing (Skylights)
Component
Width Height
Qt. Feet Inch Feet Inch
Sum of Overhead Glazing Area and UA
Overhead Glazing Area Weighted U = UA/Area
Total Sum of Fenestration AYea and UA (for heating system sizing calculations)
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0,01
0.00
168,01 45.44
0.27
Area UA
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0 0.00
0.00
188.0 49.44