Loading...
%COMBINED MECH to PR-01 3-29-239 8.8 8.6 H.7 H.4 H G.9 S-29 (RELOCATE) CD 60 ETR DEMO BRANCH AND SUPPLY DUCT. MAIN DUCT TO REMAIN TYP. 15.700 14"x14" ETR CD ETR CD ETR CD ETR RAG ETR 10"Ø ETR 10"Ø ETR 14"x12" ETR 6"Ø ETR 10"Ø ETR RTU-30 ETR RTU-30 5 TON 2000 ETR MEN WOMEN FAMILY TOILET LAYAWAY 9 8.8 8.6 H.7 H.4 H G.9 S-29 RELOCATED RTU-30 3 TON ETR RTU-29 5 TON 2000 ETR RTU-28 5 TON ETR CD2 ETR 300 CFM 15.713 CD2 ETR 300 CFM 15.713 CD ETR 335 CFM 15.713 CD ETR 60 CFM 15.713 SAW 460 12"x8" SAW 460 12"x8" 14"x14" ETR 12"x12" 6"Ø RAG1 6"Ø CD1 12"x12" 6"Ø TYP 15.705 14"x14" 14"x14" RAW 920 15.713 TG 1000 24"x24" 6"Ø ETR10"Ø ETR 10"Ø ETR 6"Ø 14"x12" ETR WOMEN MEN FAMILY TOILET MOTHERS ROOM 2 M2 1 M2 CORRIDOR ALCOVE TYP TYP engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR CONSTRUCTION EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. PROTO:176 M1 ENLARGED MECHANICAL PLANS RGDYELM, WASHINGTON2022-0339YELM, WASHINGTON01/30/2301/30/23STORE NO: 3705-23217611/11/2217100 STATE ROUTE 507 SEJEE KEYNOTES 15.700 REMOVE AIR DEVICES AND DUCTWORK SHOWN DASHED UNLESS OTHERWISE NOTED AND CAP OFF DUCTWORK TO REMAIN. PATCH AND SEAL DUCTWORK AS NEEDED INCLUDING SEALING DUCTWORK TO REMAIN PER SPECIFICATIONS. 15.705 CONNECT TO EXISTING SUPPLY/RETURN DUCTWORK INDICATED. 15.713 REBALANCE AIR DEVICE TO CFM SHOWN. REDISTRIBUTE AIR FROM EXISTING DUCTWORK TO MATCH NEW CFM REQUIREMENTS. 1/4" = 1'-0"1 REAR RESTROOM AREA MECHANICAL DEMO PLAN 1/4" = 1'-0"2 REAR RESTROOM AREA MECHANICAL PLAN ISSUE BLOCK 2 6 "Ø T O 3 6 "Ø (O R S M A L L E R )2 4 "Ø LOAD RATED FASTENERS ROUND SUPPLY AIR DUCT ROUND SUPPLY AIR DUCT BEAM CLAMP DUCT HANGER STRAP REF SPECIFICATIONS DUCT HANGER STRAP REF SPECIFICATIONS DUCT HANGER STRAP REF SPECIFICATIONS DUCT SUPPORT BAND SAME SIZE AS STRAP TOP CHORD OF JOIST TOP BEAM CLAMP TYP PERPENDICULAR TO JOIST PARALLEL TO JOIST RECTANGULAR DUCT PARALLEL TO STRUCTURE RECTANGULAR DUCT PERPENDICULAR TO STRUCTURE ROOF ROOF RECTANGULAR DUCT ROOF ROOF 2"x2"x1/4" ANGLE OR 1 5/8"x1 5/8" UNISTRUT 2"x2"x1/4" ANGLE OR 1 5/8"x1 5/8" UNISTRUT SHEET METAL SCREWS TYPTHREADED ROD TYP OPTIONAL ROUTING IN CONCEALED AREAS BOTTOM OF STRUCTURE LOADS MUST BE HUNG WITHIN 3" OF PANEL POINTS REF STRUCTURAL LOADS MUST BE HUNG WITHIN 3" OF PANEL POINTS REF STRUCTURAL SUPPLY REGISTER, REF FLOOR PLAN FOR SIZE AND LOCATION, MOUNT REGISTERS @ 30 DEGREE ANGLE DOWN FROM HORIZONTAL IN OPEN OFFICES AND STOCKROOM AREA, EXCEPT THOSE SHOWN ON BOTTOM OF DUCT ON THE PLAN BOTTOM OF STRUCTURE 2"x2"x1/4" ANGLE OR 1 5/8"x1 5/8" UNISTRUT 6" 3" MAX 3" MAX 6" 1" MIN. 6" 6" 60" MAX. LOADS MUST BE HUNG WITHIN 3" OF PANEL POINTS REF STRUCTURAL SCREWS TYP LOADS MUST BE HUNG WITHIN 3" OF PANEL POINTS W L NOTES: 1. SPIN-IN FITTINGS W/ SCOOPS ARE NOT ACCEPTABLE 2. REF PLANS FOR RUNOUT SIZES 3. 45° LEAD INAIRFLOW AIRFLO W L = W/4, 4" MIN AIRFLO W engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR CONSTRUCTION PROTO:176 M2 MECHANICAL DETAILS AND SCHEDULES RGDYELM, WASHINGTON2022-0339YELM, WASHINGTON01/30/2301/30/23STORE NO: 3705-23217611/11/2217100 STATE ROUTE 507 SEJEE MECHANICAL SYMBOLS RECTANGULAR DUCT 18" WIDE BY 12" DEEP RETURN OR EXHAUST DUCT IN SECTION SUPPLY AIR DIFFUSER WITH ROUND SUPPLY DUCT RETURN OR EXHAUST AIR DIFFUSER WITH ROUND DUCT 12" DIAMETER ROUND DUCT SUPPLY DUCT IN SECTION ELBOW WITH TURNING VANES TEE WITH TURNING VANES ROUND (OR OVAL) ELBOW BRANCH DUCT AND/OR NECK SIZE DIFFUSER OR GRILLE TYPE CFM THERMOSTAT TIMER 12" Ø 18"x12" VOLUME/BALANCE DAMPER TEMP SENSOR CONNECT TO EXISTING EXISTING TO REMAINETR FIRE DAMPERFD CD 24"x24" 450 S-X S T NTS1DUCT SUPPORT AND GRILLE NTS2HIGH EFFICIENCY BRANCH DUCT FITTING 1. 2. A. B. C. D. E. F. G. H. I. J. K. L. M. N. GENERAL INFORMATION (ALL DEVICES): INSTALL BOTTOM OF WALL MOUNTED AIR DEVICES AT ELEVATION INDICATED ON DRAWINGS UNLESS NOTED OTHERWISE. BALANCE DAMPER CONTACTS: AES - (800) 786-0402 RUSKIN - (816) 761-7476 NOTES: 6-WAY (DB1-DB3) OR 4-WAY (DB4-DB8) THROW UNLESS SHOWN OTHERWISE WITH FLOW ARROWS ON PLAN. ALL STEEL CONSTRUCTION. ALL ALUMINUM CONSTRUCTION. BRANCH DUCT SIZE SHALL BE SAME AS NOTED DIFFUSER NECK SIZE UNLESS NOTED OTHERWISE. STANDARD WHITE FINISH. PROVIDE NECK FOR DUCT CONNECTION. DROP BOX DIFFUSERS FURNISHED BY OWNER INSTALLED BY CONTRACTOR. REFERENCE SPECIFICATIONS. PROVIDE INTEGRAL OPPOSED BLADE DAMPERS ON ALL DRUM LOUVERS ON DROP BOXES WITH BRANCH DUCTWORK ATTACHED TO THE SUPPLY PLENUM. PROVIDE MANUFACTURER'S OPPOSED BLADE DAMPER ACCESSIBLE THROUGH FACE UNLESS NOTED OTHERWISE. PROVIDE WITH FASTENERS FOR COMPLETE (NON-HINGED) REMOVABILITY OF GRILLE. DO NOT PROVIDE FILTER UNLESS NOTED OTHERWISE. TWO 2" SLOTS WITH MANUFACTURER'S INSULATED PLENUM (TUTTLE & BAILEY LP, PRICE JSPI, CARNES CXPC.) REFER TO PLANS FOR DIRECTIONAL ARROWS INDICATING CFM THROWS FOR PROPER GRILLE SELECTION. NO DIRECTIONAL ARROWS INDICATES 4-WAY THROW. PROVIDE ROUND NECK ADAPTER PROVIDE CEILING TRANSITION REGISTER BOX WITH 16" OR 24" PLATE FOR ROUGH-IN. AIR DEVICE SCHEDULE MARK SERVICE MANUFACTURER MODEL STYLE FRAME TYPE FACE SIZE NOTES CD1 SUPPLY AIR TUTTLE & BAILEY E.H.PRICE CARNES M SMD SKFA ROUND NECK CEILING DIFFUSER SURFACE MOUNT REFER TO DRAWINGS B, E, I, L, M, N RAG1 RETURN AIR TUTTLE & BAILEY E.H.PRICE CARNES CRE500 80F RAPAF 1/2"x1/2"x1/2" EGGCRATE CEILING GRILLE SURFACE MOUNT REFER TO DRAWINGS C, E, I, M, N RAW RETURN AIR TUTTLE & BAILEY E.H.PRICE CARNES T75 510Z RSRBH FIXED BLADE WALL GRILLE SURFACE MOUNT REFER TO DRAWINGS B, E, I SAW SUPPLY AIR TUTTLE & BAILEY E.H.PRICE CARNES T64 520DS RTDBV LOUVERED FACE REGISTER SURFACE MOUNT REFER TO DRAWINGS B, E, F, I VOLUME / BALANCE DAMPER SCHEDULE MANUFACTURER / MODELTYPE AES / WMVCD RUSKIN / WMRS25ROUND AES / AMD4 RUSKIN / WMD25RECTANGULAR ISSUE BLOCK BADBAD A A A A A A A A2 A A A A A A A A AAAAAA AAAA A2 A A A A A AAAAAAAAAAD D D D D D D D D D D D D GRD A A AA A A A AA CLCLCLCLCLCLCL WHAZFBA AA A A A AA AA A A A A AAAA AADDDDDDDD CL W W W W DD DD DD DD DD DD DD AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA A AAAA FF FSSLAB B FB FB SSLSSLSSLAAAAFFO O A T1 T1 T1T1 T1 T1 T1 T1 T1T1 T1 T1 T1T1 T1 T1 T1 T1 T1T1T1T1T1 T1T1T1T1 T1D UUUUUUUU DDHAZ TLL92D OGP5 D6 OGP5 D8 OGP5 D8 OGP5 D6 OGP5 D8 OGP5 D8 OGP5 D6 OGP5 D8 OGP5 D8 OO O OO O O O OOO OGP2 D8 OGP2 D8 OGP2 D8 OGP2 D8 OGP2 D8 OGP2 D8 OGP2 D8 OGP2 D8 OGP2 D6 OGP2 D6 OGP2 D6 OGP2 D8 O SSL DD A A2 AP3AP3B1AP3AP3AP3B1AP3AP3AP3B1AP3AP3AP3B1AP3GRD BXLDDDDDD AA02/01/18D GR1GR1R1AAAAAAAAA A AAAA FF FMPH1 3 MP1 3 MVC1 2 13 12 11 10 9 8 7 6 5 4 3 2 1 K H G F E D C B A MP1 2 M1 1 M1 2 MVC1 1RTU-14 5 TON RTU-13 3 TON RTU-12 10 TON RTU-11 3 TON RTU-10 3 TON RTU-9 5 TON RTU-8 3 TON RTU-7 3 TON RTU-6 3 TON RTU-5 5 TON RTU-4 5 TON RTU-3 10 TON RTU-2 20 TON RTU-1 10 TON RTU-15 20 TON RTU-16 20 TON RTU-17 20 TON RTU-18 20 TON RTU-19 10 TON RTU-23 20 TON RTU-22 10 TON RTU-21 10 TON RTU-20 5 TON RTU-25 5 TON RTU-24 10 TON RTU-26 5 TON RTU-27 5 TON RTU-28 5 TON RTU-29 5 TON RTU-30 3 TON RTU-31 5 TON RTU-32 5 TON RTU-33 5 TON RTU-35 10 TON RTU-34 10 TON AHU-3 AHU-2 AHU-2 PHARMACY MPH1 1 MPH1 2 VISION SALES AMERICA'S CREDIT UNION TENANT DELI PREP DELI PREP SERVICE DELI BAKERY/DELI FREEZER BAKERY UTILITY PRODUCE COOLER PRODUCE PREP FAMILY TOILET MOTHERS ROOM MEN WOMEN WC2 15.406 REPLACE WATER CLOSET TOILET 1 5.5 5 4.2 4 3.8 C.4 C B.6 PRIOR TO SETTING NEW REFRIGERATED CASE. THOROUGHLY CLEAN ALL DEBRIS FROM FLOOR DRAIN AND/OR FLOOR SINK GRATES AND BODIES. HYDRO-JET EACH FLOOR DRAIN AND/OR FLOOR SINK TO THE MAIN. ALL REFRIGERATED CASE DIMENSIONS ARE FROM EDGE OF CASE TO CENTER OF DRAIN ALL REFRIGERATED CASE DRAIN OUTLETS SHALL BE 2" IN SIZE.1' - 2"1' - 2"2' - 8"2' - 8" 15.403 FCO ETR FD3 FCO1 FD3 3" SS 3" SS 4" SS ETR 2 P1 2" VENT DOWN IN CHASE 15.442 TYP 2" V SALES TENANT TENANT 1 P1 15.404 3" VTR, ETR 3 2.5 2 1.5 1 C B.6 B 15.405 DEMO HAND SINK 15.426 TYP OF 3 SS004R 15.402 15.401 DELI PREP SERVICE DELI CAKE DECORATING SS1 REPLACE EXISTING SERVICE SINK 15.406 EXISTING HAND SINK. EXTEND CW & HW AND WASTE FROM EXISTING HS TO NEW HANK SINK. 1 STAINLESS STEEL HAND SINKS AND COMPARTMENT SINKS: REFER TO ARCHITECTURAL PLANS FOR AFFECTED SINKS. 15.448 1 engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR CONSTRUCTION EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. PROTO:176 MP1 MECHANICAL AND PLUMBING PLAN RGDYELM, WASHINGTON2022-0339YELM, WASHINGTON01/30/2301/30/23STORE NO: 3705-23217611/11/2217100 STATE ROUTE 507 SEJEE KEYNOTES 15.401 CONNECT TO NEAREST DOMESTIC COLD WATER PIPE OF EQUAL OR LARGER SIZE. VERIFY SIZE AND LOCATION AT SITE. PROVIDE SHUT-OFF VALVE IN NEW PIPE AT POINT OF CONNECTION. 15.402 CONNECT TO EXISTING HOT WATER PIPE OF EQUAL OR LARGER SIZE. VERIFY SIZE AND LOCATION AT SITE. PROVIDE SHUT-OFF VALVE IN NEW PIPE AT POINT OF CONNECTION. 15.403 CONNECT TO EXISTING SANITARY PIPE OF EQUAL OR LARGER SIZE. VERIFY SIZE, LOCATION, ELEVATION, AND FLOW DIRECTION AT SITE. 15.404 CONNECT TO EXISTING VENT PIPE OF EQUAL OR LARGER SIZE. VERIFY SIZE AND LOCATION AT SITE. 15.405 PROPERLY CAP, PLUG AND CONCEAL ANY PIPING LEFT IN PLACE. CAP ABANDONED SEWER PIPING A MINIMUM OF 8" BELOW FINISHED FLOOR. MATCH EXISTING FLOOR CONSTRUCTION AND FINISHES. RE: ARCHITECTURAL PLANS. REMOVE UNUSED WATER AND VENT PIPING ABOVE CEILING AND CAP REMAINING PIPE. 15.406 PLUMBING CONTRACTOR TO MAKE ALL NECESSARY DISCONNECTS AND RECONNECTS OF PLUMBING FIXTURES BEING RELOCATED OR NEW. 15.426 WHERE NEW REFRIGERATED CASES ARE REPLACING EXISTING CASES AT SAME LOCATION, EXISTING FLOOR DRAINS MAY BE REUSED IF EXISTING DRAIN IS IN A REUSABLE LOCATION (VERIFY IN FIELD). 15.442 TRENCHING AND BACKFILL BY GC, REF ARCH PLANS. COORDINATE WITH GC FOR INSTALLATION SCHEDULE. 15.448 PLUMBING CONTRACTOR TO MAKE ALL NECESSARY DISCONNECTS AND RECONNECTS OF PLUMBING FIXTURES FOR FINISHES WORK. PROVIDE CONTINUOUS SEALANT ALONG THE EDGES OF RECONNECTED FIXTURES. REFURBISH URINAL AND WC FLUSH VALVES TO LIKE NEW OPERATING CONDITION. 1" = 30'-0"1 MECHANICAL AND PLUMBING PLAN GENERAL NOTES 21. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY LOCATION AND SIZES OF ALL EXISTING PIPING THAT IS BEING CONNECTED TO OR MODIFIED, AND TO VERIFY THAT PROPER SLOPES AND ELEVATIONS ARE AVAILABLE BEFORE CUTTING FLOOR SLAB. MAINTAIN MINIMUM SLOPE OF 1/8" PER FOOT FOR SAN SEWER PIPING 3" OR LARGER. MAINTAIN MINIMUM SLOPE OF 1/4" PER FOOT FOR SAN SEWER PIPING SMALLER THAN 3". [MAINTAIN 1/4" PER FLOOR SLOPE FOR GREASE WASTE PIPING.] REF ARCH. FOR TRENCHING REQUIREMENTS. 22. SLOPE INTERIOR CONDENSATE PIPING AT 1/8" PER FOOT WHEN NOT INSTALLED PARALLEL TO ROOF SLOPE. 23. PROVIDE ACCESS DOORS TO NEW WATER VALVES AND CLEANOUTS AS NECESSARY WHEN INSTALLED IN INACCESSIBLE AREAS. 24. PLUMBING CONTRACTOR SHALL PROVIDE ONE YEAR WARRANTY FOR PROPER SEWER SYSTEM OPERATION. 25. SANITARY DRAINAGE LINES AND FITTINGS (DRAIN, WASTE AND VENT) SHALL BE PVC-DWV PLASTIC SCHEDULE 40. WHERE REQUIRED BY LOCAL CODES, CAST IRON, COATED INSIDE AND OUTSIDE SHALL BE USED IN LIEU OF PVC. ALL PHOTOLAB PLUMBING SHALL BE PVC. REFERENCE SPECIFICATIONS. 26. WATER PIPING ABOVE GRADE SHALL BE TYPE "L" HARD DRAWN COPPER JOINED WITH WROUGHT COPPER FITTINGS. MAKE JOINTS USING LEAD-FREE SOLDER AND A NON-CORROSIVE, PASTE-TYPE FLUX. MAKE PIPING CONNECTIONS TO A FIXTURE WITH CHROME-PLATED SEAMLESS BRASS TUBE. INSULATE HOT & COLD WATER PIPING WITH RIGID GLASS FIBER A MINIMUM OF 1/2" THICK WITH WHITE ALL-SERVICE JACKET (VAPOR RETARDER). AT CONTRACTOR'S OPTION (U.N.O), IN LIEU OF COPPER WATER PIPING, PEX OR AQUATHERM PIPING MAY BE USED. REFER TO EQUIVALENT NOMINAL PIPE SIZES SCHEDULE AND SPECIFICATIONS. 27. PROVIDE AUTOMATIC TRAP PRIMERS OR BARRIER- TYPE TRAP SEAL PROTECTION ON FLOOR DRAINS WHERE NOT OTHERWISE NOTED IF REQUIRED BY LOCAL PLUMBING CODES. 28. FLOOR CLEANOUTS SHALL BE INSTALLED FLUSH WITH FLOOR FINISH MATERIAL OR FLUSH WITH CONCRETE SLAB IF NO FLOOR FINISH MATERIAL IS CALLED OUT FOR ON ARCHITECTURAL DRAWINGS. 29. CUT AND PATCH EXISTING CONCRETE FLOOR SLAB FOR INSTALLATION OF NEW UNDERGROUND PLUMBING PIPE. FLOOR CUTS SHALL BE STRAIGHT AND CLEAN, REPLACE REMOVED SLAB WITH CONCRETE FLUSH AND SMOOTH WITH ADJACENT FLOOR SLAB. MATCH EXISTING CONSTRUCTION REFERENCE SPEC SECTION 01721. COORDINATE WITH WALMART CONSTRUCTION MANAGER. 30. CAP ALL PIPING OPENINGS DURING CONSTRUCTION UNTIL FINAL CONNECTIONS TO EQUIPMENT AND ACCESSORIES ARE MADE. 31. DO NOT INSTALL PIPING WITHIN COOLER PANELS. INSTALL EXPOSED PIPING IN PREP AREAS A MINIMUM OF 1/2" FROM PANEL WALL AND 6" ABOVE FINISHED FLOOR TO ALLOW FOR CLEANING. USE ONLY NON- CORROSIVE MATERIALS FOR SPACERS AND ANCHORS. 32. PROVIDE ESCUTCHEON PLATES FOR PLUMBING PENETRATIONS THROUGH GROCERY CEILINGS AND WALLS. PROVIDE AIR TIGHT SEAL AROUND PIPING PENETRATIONS THROUGH COOLER/FREEZER WALLS AND CEILINGS. FINISH WITH ESCUTCHEON PLATE. 33. PROVIDE HEAT TAPE AND INSULATION ON ALL WATER AND DRAIN PIPING EXPOSED TO FREEZING. 34. INSTALL CONTINUOUS SEALANT JOINT AT ALL EXTERIOR WALL PENETRATIONS. 35. INSTALL VTR'S A MINIMUM OF 24" FROM ROOF EDGE AND/OR PARAPET WALLS AND A MINIMUM OF 10 FT FROM OUTSIDE AIR INTAKE OF ROOF TOP UNITS. 36. PROVIDE SEISMIC BRACING BASED ON APPROPRIATE SEISMIC ZONE REQUIREMENTS PER SMACNA PUBLISHED SEISMIC DETAILS, LOCAL AND NATIONAL CODES. CONTRACTOR'S RESPONSIBILITY INCLUDES STRUCTURAL ENGINEER'S CERTIFICATION ON DETAILS SUBMITTED FOR PERMITTING. 37. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE FUTURE. 1. GENERAL NOTES ARE APPLICABLE TO ALL MECHANICAL AND PLUMBING DRAWINGS. 2. PROVIDE ALL MATERIALS FOR A COMPLETE INSTALLATION PER PROJECT SPECIFICATIONS AND READY FOR INTENDED USE AND IN STRICT ACCORDANCE WITH STATE AND LOCAL CODES AND MANUFACTURERS RECOMMENDATIONS. 3. STORE MUST BE KEPT IN OPERATION. ARRANGE ALL WORK TO KEEP DISRUPTIONS TO STORE OPERATIONS TO A MINIMUM. COORDINATE WITH EXISTING AND NEW CONSTRUCTION. PAY ALL NECESSARY FEES AND PERMITS. 4. IF NEW CONSTRUCTION DISRUPTS EXISTING SERVICES (GAS, SEWER, DOMESTIC WATER, ETC.), PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO MAINTAIN THEIR PROPER OPERATION. 5. EMPLOY OWNER APPROVED ROOFING CONTRACTORS FOR CUTTING AND PATCHING ROOF. REFERENCE SPECIFICATIONS FOR APPROVED ROOFING CONTRACTORS. 6. INSTALL OWNER FURNISHED RTU CURB AND TEMPORARY COVER CURB PER ARCH DETAIL (IF USED). RTU'S SHALL BE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. CURB ADAPTOR (IF USED) SHALL BE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. RTU SHALL BE SET ON ROOF CURB. DO NOT SET RTU DIRECTLY ON ROOF. COORDINATE RTU INSTALLATION WITH WALMART CONSTRUCTION MANAGER AND AES AS REQUIRED FOR RTU/AHU CURB ADAPTERS. 7.-14. NOT USED. 15. COORDINATE DUCTWORK WITH LIGHT FIXTURES. LIGHT FIXTURE LOCATIONS TAKE PRECEDENCE. FIELD VERIFY STRUCTURAL CONDITIONS BEFORE FABRICATION OF DUCTWORK. 16. FLEXIBLE DUCT CONNECTIONS TO NEW OR RELOCATED DIFFUSERS AND GRILLES ARE PROHIBITED. 17. DUCT SIZES SHOWN ON DRAWINGS ARE NET FREE AREA. CONTRACTOR'S OPTION, ROUND DUCTWORK OF EQUIVALENT FREE AREA MAY BE USED IN LIEU OF RECTANGULAR. INCREASE RECTANGULAR SHEET METAL SIZE AS REQUIRED FOR LINER. REFER TO SPECIFICATIONS FOR THE INSULATION THICKNESS. 18. DUCT SUPPORT AND GRILLE DETAIL IS APPLICABLE THROUGHOUT THE STORE. DO NOT USE FASTENERS THAT PENETRATE ROOF DECK. 19. TYPICAL BRANCH DUCT FITTING DETAIL IS APPLICABLE THROUGHOUT THE STORE. 20. INSTALL ASSET TAGS ON ALL NEW RTUS, AHUS, EXHAUST FANS, AND SPLIT SYSTEMS AND COMPLETE THE DATA COLLECTION INFORMATION. DELETE DEMOED ASSETS FROM ASSET TAGGING APPLICATION. REFER TO SPECIFICATIONS. 1/8" = 1'-0"2 GR GRAB & GO WASTE AND VENT PLAN 1/8" = 1'-0"3 FRONT GROCERY PLUMBING PLAN ISSUE BLOCK 1 PR#1 03/29/23 1 02/01/18 02/01/18 02/01/18 9 8.8 8.6 C B.6 DEMO CD CD ETRCD ETR CD ETR CD ETR CD ETR 14"x14" ETR 12"x12" ETR 8"Ø ETR 16"x20" RAG ETR 14"x20" RTU-14 5 TON 2000 ETR RAG ETR 9 8.8 8.6 C B.6 B RTU-14 5 TON 2000 ETR S-14 ETRCD ETR 335 15.713 CD ETR 335 15.713 CD ETR 335 CD ETR 335 15.713 RAG ETR 1470 TG ETR TG ETR RAG ETR 330 CD ETR 430 15.713 AP OFFICE PICKUP STORAGE PHARMACY TOILET HEALTH SERVICES 8"Ø 8"Ø ETR CD ETR 70 15.713 10"Ø ETR 42"x30" TRANSFER ETR 14"x14" ETR 12"x12" ETR 16"x20" ETR 10"Ø ETR 10"Ø ETR CEILING RETURN GRILLE SUPPLIED AND INSTALLED BY PANEL MANUFACTURER 12"x12" FACE SIZE 8" ROUND NECK SIMILAR TO TITUS TDC 150 CFM CEILING DIFFUSER SUPPLIED AND INSTALLED BY PANEL MANUFACTURER 12"x12" FACE SIZE 8" ROUND NECK SIMILAR TO TITUS TDC 150 TDC FINAL DUCTWORK CONNECTION TO PRE-INSTALLED DIFFUSER BY GENERAL CONTRACTOR 6"Ø ETR 10"Ø ETR 10"Ø ETR 12"Ø ETR 15.713 1 M2 15.705 2 M2 INSTALL DAMPER IN VERTICAL AT 24" MAX ABOVE CEILING BALANCE TO 1320 CFM 9 8.8 8.6 C B.6 NEW SINK FURNISHED BY MILL WORK MFG. INSTALLED BY GC. 15.406 DISCONNECT/RECONNECT EXISTING WATER FILTRATION SYSTEM. WATER HEATER AS NECESSARY. PHARMACY HEALTH SERVICES TOILET EXIST WC 15.448 1 engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR CONSTRUCTION EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. PROTO:176 MPH1 PHARMACY MECHANICAL AND PLUMBING PLANS RGDYELM, WASHINGTON2022-0339YELM, WASHINGTON01/30/2301/30/23STORE NO: 3705-23217611/11/2217100 STATE ROUTE 507 SEJEE 1/8" = 1'-0"1 PHARMACY MECHANICAL DEMO PLAN 1/4" = 1'-0"2 PHARMACY MECHANICAL PLAN 1/4" = 1'-0"3 PHARMACY PLUMBING PLAN KEYNOTES 15.406 PLUMBING CONTRACTOR TO MAKE ALL NECESSARY DISCONNECTS AND RECONNECTS OF PLUMBING FIXTURES BEING RELOCATED OR NEW. 15.448 PLUMBING CONTRACTOR TO MAKE ALL NECESSARY DISCONNECTS AND RECONNECTS OF PLUMBING FIXTURES FOR FINISHES WORK. PROVIDE CONTINUOUS SEALANT ALONG THE EDGES OF RECONNECTED FIXTURES. REFURBISH URINAL AND WC FLUSH VALVES TO LIKE NEW OPERATING CONDITION. 15.705 CONNECT TO EXISTING SUPPLY/RETURN DUCTWORK INDICATED. 15.713 REBALANCE AIR DEVICE TO CFM SHOWN. REDISTRIBUTE AIR FROM EXISTING DUCTWORK TO MATCH NEW CFM REQUIREMENTS. ISSUE BLOCK 1 PR#1 03/29/23 1 7.8 7 B.6 B A RTU-10 3 TON 1200 ETR RTU-11 3 TON 1200 ETR CONTRACTOR TO FIELD VERIFY SITE SPECIFIC CONDITIONS AT THE OPTICAL SALES AREA CEILING. IF THERE IS A CONFLICT IN LOCATING THE CEILING FEATURE WHILE MAINTAINING THE EXISTING DUCTWORK LAYOUT, THE CONTRACTOR SHALL CONTACT THE ARCHITECT OF RECORD THROUGH THE RI PROCESS. CONTRACTOR TO REPLACE DIFFUSERS AND RETURN AIR GRILLES AT VISION CENTER OPTICAL SALES. CONNECT TO EXISTING DUCTWORK. ALL OTHER CEILING DIFFUSERS, RETURN ARE GRILLES ARE EXISTING TO REMAIN ETR) PRETEST EXAM #1 ADJUSTMENTS CONTACTS WAITING VISION CENTER CEILING DIFFUSER MODULE SIZE 24x24 NECK SIZE AND CFM AS NOTED ON PLAN SIMILAR TO TUTTLE & BAILEY PP MODEL PERFORATED DIFFUSER WITH ROUND NECK AND LT FRAME STYLE CEILING RETURN AIR GRILLE MODULE SIZE 24x24 NECK SIZE AND CFM AS NOTED ON PLAN SIMILAR TO TUTTLE & BAILEY PR MODEL REFORATED RETURN GRILLE WITH ROUND NECK AND LT FRAME STYLE TG 10"Ø 300 10"Ø 300 10"Ø 300 10"Ø 300 TG 16"Ø 1200 S-10 S-11 ETR RELOCATE S-10 RELOCATED 7.8 7 B A NEW SINK FURNISHED BY OWNER FINAL CONNECTION BY GC CONNECT TO EXISTING DWV AND WATER SERVICE REPLACE TAILPIECE, P-TRAP, SUPPLY LINES AND SHUT-OFF VALVES. SINK 15.401 15.402 15.403 15.404 15.406 ADJUSTMENTS VISION CENTER WAITING CONTACTS EXAM #1 PRETEST engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR CONSTRUCTION EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. PROTO:176 MVC1 VISION CENTER MECHANICAL AND PLUMBING PLANS RGDYELM, WASHINGTON2022-0339YELM, WASHINGTON01/30/2301/30/23STORE NO: 3705-23217611/11/2217100 STATE ROUTE 507 SEJEE 1/4" = 1'-0"1 VISION CENTER MECHANICAL PLAN 1/4" = 1'-0"2 VISION CENTER PLUMBING PLAN KEYNOTES 15.401 CONNECT TO NEAREST DOMESTIC COLD WATER PIPE OF EQUAL OR LARGER SIZE. VERIFY SIZE AND LOCATION AT SITE. PROVIDE SHUT-OFF VALVE IN NEW PIPE AT POINT OF CONNECTION. 15.402 CONNECT TO EXISTING HOT WATER PIPE OF EQUAL OR LARGER SIZE. VERIFY SIZE AND LOCATION AT SITE. PROVIDE SHUT-OFF VALVE IN NEW PIPE AT POINT OF CONNECTION. 15.403 CONNECT TO EXISTING SANITARY PIPE OF EQUAL OR LARGER SIZE. VERIFY SIZE, LOCATION, ELEVATION, AND FLOW DIRECTION AT SITE. 15.404 CONNECT TO EXISTING VENT PIPE OF EQUAL OR LARGER SIZE. VERIFY SIZE AND LOCATION AT SITE. 15.406 PLUMBING CONTRACTOR TO MAKE ALL NECESSARY DISCONNECTS AND RECONNECTS OF PLUMBING FIXTURES BEING RELOCATED OR NEW. ISSUE BLOCK