Loading...
%COMBINED PLUMBING to PR-01 3-29-2302/01/18 02/01/18 02/01/18 9 8.8 8.6 C B.6 DEMO CD CD ETRCD ETR CD ETR CD ETR CD ETR 14"x14" ETR 12"x12" ETR 8"Ø ETR 16"x20" RAG ETR 14"x20" RTU-14 5 TON 2000 ETR RAG ETR 9 8.8 8.6 C B.6 B RTU-14 5 TON 2000 ETR S-14 ETRCD ETR 335 15.713 CD ETR 335 15.713 CD ETR 335 CD ETR 335 15.713 RAG ETR 1470 TG ETR TG ETR RAG ETR 330 CD ETR 430 15.713 AP OFFICE PICKUP STORAGE PHARMACY TOILET HEALTH SERVICES 8"Ø 8"Ø ETR CD ETR 70 15.713 10"Ø ETR 42"x30" TRANSFER ETR 14"x14" ETR 12"x12" ETR 16"x20" ETR 10"Ø ETR 10"Ø ETR CEILING RETURN GRILLE SUPPLIED AND INSTALLED BY PANEL MANUFACTURER 12"x12" FACE SIZE 8" ROUND NECK SIMILAR TO TITUS TDC 150 CFM CEILING DIFFUSER SUPPLIED AND INSTALLED BY PANEL MANUFACTURER 12"x12" FACE SIZE 8" ROUND NECK SIMILAR TO TITUS TDC 150 TDC FINAL DUCTWORK CONNECTION TO PRE-INSTALLED DIFFUSER BY GENERAL CONTRACTOR 6"Ø ETR 10"Ø ETR 10"Ø ETR 12"Ø ETR 15.713 1 M2 15.705 2 M2 INSTALL DAMPER IN VERTICAL AT 24" MAX ABOVE CEILING BALANCE TO 1320 CFM 9 8.8 8.6 C B.6 NEW SINK FURNISHED BY MILL WORK MFG. INSTALLED BY GC. 15.406 DISCONNECT/RECONNECT EXISTING WATER FILTRATION SYSTEM. WATER HEATER AS NECESSARY. PHARMACY HEALTH SERVICES TOILET EXIST WC 15.448 1 engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR CONSTRUCTION EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. PROTO:176 MPH1 PHARMACY MECHANICAL AND PLUMBING PLANS RGDYELM, WASHINGTON2022-0339YELM, WASHINGTON01/30/2301/30/23STORE NO: 3705-23217611/11/2217100 STATE ROUTE 507 SEJEE 1/8" = 1'-0"1 PHARMACY MECHANICAL DEMO PLAN 1/4" = 1'-0"2 PHARMACY MECHANICAL PLAN 1/4" = 1'-0"3 PHARMACY PLUMBING PLAN KEYNOTES 15.406 PLUMBING CONTRACTOR TO MAKE ALL NECESSARY DISCONNECTS AND RECONNECTS OF PLUMBING FIXTURES BEING RELOCATED OR NEW. 15.448 PLUMBING CONTRACTOR TO MAKE ALL NECESSARY DISCONNECTS AND RECONNECTS OF PLUMBING FIXTURES FOR FINISHES WORK. PROVIDE CONTINUOUS SEALANT ALONG THE EDGES OF RECONNECTED FIXTURES. REFURBISH URINAL AND WC FLUSH VALVES TO LIKE NEW OPERATING CONDITION. 15.705 CONNECT TO EXISTING SUPPLY/RETURN DUCTWORK INDICATED. 15.713 REBALANCE AIR DEVICE TO CFM SHOWN. REDISTRIBUTE AIR FROM EXISTING DUCTWORK TO MATCH NEW CFM REQUIREMENTS. ISSUE BLOCK 1 PR#1 03/29/23 1 SPECIALTY PLUMBING FIXTURE SCHEDULE MARK FIXTURE MANUFACTURER MODEL FIXTURE DESCRIPTION WPG WATER PRESSURE GAUGE AMETEK TRERICE WEISS INSTRUMENTS 656 D83LFSS LF252 2.5 INCH STAINLESS STEEL CASE, ALL WETTED PARTS STAINLESS STEEL, LIQUID FILLED, 1/4 INCH NPT CONNECTOR, 1.6% ACCURACY, 30" HG VAC TO 100 PSI RANGE. WHA WATER HAMMER ARRESTOR JOSAM PRECISION PLUMBING PRODUCTS WATTS WILKINS JAY R. SMITH SIOUX CHIEF MIFAB SERIES 75000 STAINLESS STEEL #316 SERIES SS SERIES MODEL 1250XL SERIES HYDROTROLS HYDRA-RESTER MWH LEAD FREE CONFORM TO PDI WH-201, ANSI A112.26.1M, ASSE 1010. FCV30 FLOW CONTROL VALVE BELL & GOSSETT FLOW DESIGN # CB LF "CIRCUIT SETTER PLUS" ICSS050 LEAD FREE NAMEPLATE AND 1/2" VALVE BODY SIZE UNLESS SHOWN OTHERWISE ON PLANS. SET AND BALANCE TO 0.25 GPM OR PROVIDE 0.25 GPM CARTRIDGE UNLESS SHOWN OTHERWISE ON PLANS AND PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. DCV DOUBLE-CHECK VALVE BACKFLOW PREVENTER (STAINLESS STEEL) WATTS SS007QT-S ASSE 1015, 316 STAINLESS STEEL BODY, QUARTER TURN TEST COCKS, QUARTER TURN, FULL PORT BALL VALVES AND STAINLESS STEEL STRAINER. ---CHECK VALVES RED-WHITE APOLLO CRANE WATTS NIBCO 232 SERIES 61-100 119J 6 T-413 BRASS JACKET WITH PLASTIC VALVE ASSEMBLY ---DOUBLE-CHECK VALVE BACKFLOW PREVENTER WATTS BEECO FEBCO WILKINS LF007QT OR LF709 FDC-LF LF850 350XL OR 950XLT2 LEAD FREE, INCLUDE TWO INDEPENDENT-ACTING CHECK VALVES, TWO SHUT-OFF VAVLES AND REQUIRED MEANS FOR TESTING FOR EACH ASSEMBLY. MINIMUM 175 PSI WORKING PRESSURE. ---LOCKABLE SHUT OFF VALVES RED-WHITE APOLLO CRANE WATTS 5042 SERIES 70LF-100 LF-T-255 LFB-6000 OR LFB-6001 BRASS BALL VALVES WITH PLASTIC JACKETED LEVER TYPE HANDLE. ---REDUCED PRESSURE BACKFLOW PREVENTER WATTS BEECO FEBCO WILKINS LF009QT OR LF909 FRP-LF LF860 375XL OR 975XL LEAD FREE, PROVIDE STRAINER, SHUT-OFF VALVES AND TEST COCKS: INSTALL DRAIN LINE WITH AIR GAP ASSEMBLY TO RECEPTOR APPROVED BY AUTHORITY HAVING JURISDICTION. MINIMUM 175 PSI WORKING PRESSURE. ---STRAINER WATTS APOLLO LF777SI 59-004-06 CAST BRONZE Y-STRAINER WITH BALL VALVE ---TRAP PRIMER (MULTIPLE TRAPS) PRECISION PLUMBING PRODUCTS MIFAB JOSAM SIOUX CHIEF PRIME RITE OR OREGON #1 M-500-NPB 88300 SERIES 695 LEAD FREE, PROVIDE ALL BRONZE PRIMER VALVE WTIH REMOVABLE OPERATING PARTS, INTEGRAL VACUUM BREAKER, GASKETED ACCESS COVER, AND MULTIPLE TRAP CAPABILITY ---TRAP PRIMER (SINGLE TRAP) PRECISION PLUMBING PRODUCTS SIOUX CHIEF PRIME-RITE OR OREGON #1 695 LEAD FREE, PROVIDE ALL BRONZE PRIMER VALVE WITH REMOVABLE OPERATING PARTS, INTEGRAL VACUUM BREAKER, AND GASKETED ACCESS COVER. ---VACUUM RELIEF VALVE WATTS LFN36-M1 LEAD FREE BRASS BODY. CSA/ANSI Z21.22 ---VALVES RED-WHITE APOLLO CRANE WATTS NIBCO 5044AB OR 5049AB SERIES 70 LF LF9210 SERIES LFFBV-3C OR LFFBVS-3C FP-600-A-LF LEAD FREE FULL PORT BRASS BALL VALVE WITH PLASTIC JACKETED LEVER TYPE HANDLE. GENERAL INFORMATION: 1. THIS SCHEDULE IS COMPREHENSIVE. ALL MARKS MAY OR MAY NOT BE USED. ---REDUCED PRESSURE BACKFLOW PREVENTER (STAINLESS STEEL) WATTS SS009M3QT-S LEAD FREE, STAINLESS STEEL REDUCED PRESSURE ZONE ASSEMBLY. FURNISHED WITH STAINLESS STEEL STRAINER, VANDAL RESISTANT TEST COCKS, AND FULL PORT QUARTER TURN BALL VALVE SHUTOFFS. INSTALL DRAIN LINE WITH AIR GAP ASSEMBLY TO RECEPTOR APPROVED BY AUTHORITY HAVING JURISDICTION. MINIMUM 175 PSI WORKING PRESSURE. ---BARRIER-TYPE TRAP SEAL PROTECTION SURE SEAL JAY R SMITH SS4009 2692 INLINE FLOOR DRAIN TRAP SEAL. ASSE 1072 FLOOR SLAB ON GRADE LONG SWEEP ELBOW AT END OR TURN OF RUN DIRECTION OF FLOW COMBINATION WYE AND EIGHTH BEND IN RUN. ENTER TOP OF PIPE. SAME SIZE AS SEWER UP TO 4" MAXIMUM MEMBRANE CLAMP REFRIGERATED CASE KICKPLATE LOCATE FLOOR DRAIN WHERE SHOWN ON DIMENSIONED PLUMBING FLOOR PLAN FLOOR DRAIN BODY WITH 2" OULET PIPE INCREASER (IF REQUIRED) NOTE: PIPE INCREASER ONLY REQUIRED IF CONNECTING WASTE LINE SIZE SHOWN ON PLANS IS LARGER THAN FLOOR DRAIN OUTLET SIZE FLOOR ALL DRAINS AND CLEANOUTS ON THE SALES FLOOR SHALL BE FLUSH WITH THE TOP OF CONCRETE SLAB; DO NOT SLOPE FLOOR TO THESE DRAINS ACCESS TO CONDENSATE DRAIN IS THRU REMOVABLE PANEL ON FRONT OF REFRIGERATED CASE INSTALL OPEN HALF OF GRATE UNDER REFRIGERATED CASE CASE CONDENSATE DRAIN, END OPEN OVER DRAIN WITH AIR GAP REF REFRIGERATION DEEP-SEAL P-TRAP MIN. 4" WATER SEAL engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR CONSTRUCTION PROTO:176 P1 PLUMBING DETAILS AND SCHEDULES RGDYELM, WASHINGTON2022-0339YELM, WASHINGTON01/30/2301/30/23STORE NO: 3705-23217611/11/2217100 STATE ROUTE 507 SEJEE PLUMBING SYMBOLS WALL CLEANOUT HOSE BIBB FREEZE PROOF WALL HYDRANT YARD CLEANOUT FLOOR SINK ROOF DRAIN/OVERFLOW ROOF DRAIN FLOOR DRAIN T & P RELIEF VALVE WATER HAMMER ARRESTOR BACKFLOW PREVENTER SHUT-OFF VALVE IN VERTICAL LINE CHECK VALVE PLUG VALVE BALL VALVE TEE - TURNED UP TEE - TURNED DOWN ELBOW - TURNED UP ELBOW - TURNED DOWN COMPRESSED AIR NATURAL GAS DOMESTIC HOT WATER DOMESTIC HOT WATER RETURN DOMESTIC COLD WATER OVERFLOW ROOF DRAIN LINE ROOF DRAIN LINE OIL WASTE GREASE WASTE SANITARY SEWER TEPID OR TEMPERED WATER WATER METER FILTERED WATER STORM SEWER IRRIGATION WATER THERMOSTATIC MIXING VALVE GAS COCK GAS PRESSURE REGULATOR PLUMBING VENT REVERSE OSMOSIS WATER CONDENSATE DRAIN CONNECT TO EXISTING EXISTING TO REMAIN PLUMBING VACUUM DEMO PIPE AREA OF SLAB CUT FLOW CONTROL VALVE THERMOMETER SS GW OW ST RD ORD IW T UNION F G A CD RO V VAC M WHA TMV FD FS YCO FPWH HB WCO ETR RD VENT BELOW FLOORVBF FLOOR CLEANOUTFCO NTS2FLOOR CLEANOUT NTS1REFRIGERATED CASE DRAIN 1. 2. GENERAL INFORMATION (AS APPLICABLE): REFER TO PLANS FOR DRAIN OUTLET SIZE. AMSE LOAD CLASSIFICATIONS: LIGHT DUTY <2000 LBS, MEDIUM DUTY 2000 - 4999 LBS, HEAVY DUTY 5000 - 7499 LBS, EXTRA HEAVY DUTY 7500 - 9999 LBS. CLEANOUT SCHEDULE ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED B Y CONTRACTOR. REFER TO SPECIFICATIONS. MARK MANUFACTURER MODEL DESCRIPTION FCO1 ZURN SIOUX CHIEF MIFAB JAY R. SMITH JOSAM WATTS OATEY Z1400 852 C1100 4231 55000 CO-200-RX-4 74000 CAST IRON OR PVC BODY, ROUND EXTRA HEAVY-DUTY CAST OR DUCTILE IRON TOP, POLYPROPYLENE OR ABS PLUG, ADJUSTABLE TO FINISH SURFACE. FLOOR DRAIN SCHEDULE ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. REFER TO SPECIFICATIONS. MARK MANUFACTURER MODEL DESCRIPTION FD3 SIOUX CHIEF JOSAM 860 FD-370 LIGHT DUTY PVC WITH 9" DIAMETER LOOSE SET PVC HALF GRATE 1. A. B. C. D. E. F. G. GENERAL INFORMATION (ALL FIXTURES): SUBSTITUTIONS NOT PERMITTED. REF SPECIFICATIONS FOR APPROVED MANUFACTURERS OF THE FOLLOWING TRIM AND ACCESSORIES: -P-TRAP WITH CLEANOUT PLUG AND SINK CONTINUOUS WASTES: POLISHED CHROME-PLATED TUBULAR BRASS, 17 GAUGE WITH BRASS NUTS AND SLIP INSERTS. -SS BRAIDED WATER SUPPLY: FLEXIBLE BRAIDED STAINLESS STEEL (SS) OUTER SHEATHING WITH REINFORCED PVC INNER TUBING. -STOP VALVES: CHROME PLATED BRASS, QUARTER TURN ANGLE STOP VALVES. NOTES: MOUNT EYEWASH 36" AFF TO TOP OF HEAD SPRAY. INSTALL MOP SINK FAUCET AT 32" AFF AND LOCATE TWO MOP HANGER BRACKETS SIDE BY SIDE NEAR MOP SINK. FURNISH WITH ZURN TMV (MODEL ZW3870XLT) UNLESS SERVED WITH TEMPERED WATER OR NOTED OTHERWISE ON PLUMBING DRAWINGS. SET AT 120° F. TRIM WITH OFFSET TAILPIECE, 5/8" ARMAFLEX INSULATION ON EXPOSED HOT WATER AND DRAIN LINES. HOLD ALL EXPOSED PIPING HIGH AS POSSIBLE. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR ACTUAL ROUGH-IN HEIGHT REQUIREMENTS. FURNISH WITH 1/2" X 2 1/2" STAINLESS STEEL SIMPSON WEDGE-ALL ANCHORS FOR ALL FIXTURES. CONTRACTOR TO COORDINATE THE REQUIRED CARRIER PRIOR TO ORDERING. PLUMBING FIXTURE SCHEDULE ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. REFER TO SPECIFICATIONS. MARK FIXTURE BRANCH SIZES (MIN) MANUFACTURER MODEL DESCRIPTION, TRIM AND ACCESSORIES NOTESCW HW WASTE VENT SS1 SERVICE SINK (TERRAZZO) 24" x 24" x 12" 3/4" 3/4" 3" 2" STERN-WILLIAMS FIAT ACORN SB-800 TSB-200 TSH-24-SSC-LB CHROME PLATED FAUCET WITH INTEGRAL CHECK VALVES, HOSE, BRACKET (MOUNT DIRECTLY ABOVE WALL GUARD), MOP HANGER (60"AFF). FAUCET: CHICAGO 897-CP (DISCARD STANDARD SUPPLY ARMS & CONNECT (2) GCJKCP SUPPLY ARMS USING (2) 897-020JKRCF ADAPTERS), ZURN Z843M1-CS, T&S BRASS B-0665-BSTP W/ ETERNA CARTRIDGES & SPRING CHECKS. HOSE/BRACKET: STERN WILLIAMS T-35, FIAT 832-AA, ACORN KH36. MOP HANGER: STERN WILLIAMS T-40, FIAT 889-CC, ACORN KMH. B ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. REFER TO SPECIFICATIONS. GROCERY PLUMBING EQUIPMENT CONNECTION SCHEDULE MARK FIXTURE BRANCH SIZES (MIN) ROUGH-IN REQUIREMENTS NOTESRO CW HW WASTE VENT GAS SS004R WALL MOUNTED HAND SINK WITH RH SPLASH 1/2" 1/2" 1 1/2" 1 1/4" WATER: 18" AFF; WASTE: 18" AFF B, C, F, J, N 1. A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. Q. R. S. T. U. V. W. X. Y. Z. GENERAL INFORMATION (ALL EQUIPMENT): EQUIPMENT AND TRIM FURNISHED BY OWNER. ROUGH-IN AND FINAL CONNECTIONS BY PLUMBING CONTRACTOR, UNLESS NOTED OTHERWISE. NOTES: PROVIDE SHUT-OFF VALVES. PROVIDE P-TRAP WITH CLEANOUT PLUG AND ESCUTCHEON. PROVIDE CHROME PLATED ANGLE SUPPLY, FLEXIBLE RISER, AND WHEEL HANDLE WITH ESCUTCHEON. SINK FAUCETS PROVIDED WITH INTEGRAL CHECK VALVES. PROVIDE FULL-SIZE DRAIN LINE FROM EQUIPMENT, END OPEN OVER RECEPTOR WITH 2" AIR GAP. IF PLUMBING PLAN SHOWS THE SINK INDIRECTLY CONNECTED TO FLOOR SINK, THEN WASTE ROUGH-IN HEIGHT AND VENT SIZE AND NOTE B DO NOT APPLY. PROVIDE DOUBLE CHECK BACKFLOW PREVENTER ON WATER SUPPLY. PROVIDE FEMALE NPT VALVE DOWNSTREAM OF BACKFLOW PREVENTER FOR CONNECTION BY OTHERS. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL FLEXIBLE WATER PIPING AND QUICK DISCONNECT TO EQUIPMENT. PROVIDE STAINLESS STEEL DOUBLE CHECK BACKFLOW PREVENTER EQUAL TO WATTS SS007QT-S ON RO WATER SUPPLY. PROVIDE PEX TUBING ON DOWNSTREAM SIDE OF BACKFLOW PREVENTER. INSTALL THERMOSTATIC MIXING VALVE FURNISHED WITH SINK WITH HARD-PIPED CONNECTIONS TO ANGLE STOPS AND FLEXIBLE CONNECTIONS BETWEEN THERMOSTATIC MIXING VALVE, FOOT PEDAL (PEDESTAL HAND SINK) OR KNEE LEVER (WALL MOUNTED HAND SINK) OR WRIST BLADE LEVERS (ADA WALL MOUNTED HAND SINK) AND SINK. SET AT 105°F. IF RO WATER IS NOT AVAILABLE, PROVIDE INDIVIDUAL WATER FILTER PACKS AS REQUIRED BY WALMART CONSTRUCTION MANAGER. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL EXPOSED DOUBLE CHECK BACKFLOW PREVENTER (WATTS #007 OR EQUAL). PROVIDE COLD WATER INJECTOR OPTION IF ON PLAN OR REQUIRED BY AHJ. REQUIRES 1/2" CW LINE AT FLOOR DRAIN. MODEL #CWI-500. REFER TO ARCHITECTURAL DRAWINGS FOR HAND SINK LEFT (L) AND RIGHT (R) DESIGNATIONS WHICH INDICATE INTEGRAL SPLASHGUARD LOCATIONS OR HAND SINK (H) FOR ADA DESIGNATION. REFRIGERATION CONTRACTOR TO INSTALL MISTING SYSTEM. SUPPLY SIDE ROUGH-IN AND FINAL CONNECTION BY PLUMBING CONTRACTOR. RO VENDOR SHALL BE RESPONSIBLE FOR LOCATIONS OF DRINK DISPENSER AND WATER FILTRATION EQUIPMENT AND ALL FINAL CONNECTIONS. PROVIDE 1 1/2" P-TRAP AT 12"AFF WITH 1 1/2" TO 3/4" REDUCER FOR CONNECTION TO RO WATER DISPENSER DRAIN. PROVIDE 3/4" I.D. FEMALE FITTING AND SHUT-OFF FOR RO DISPENSER WATER CONNECTION AT 18"AFF. INSTALL 1.2 GPM SPRAY HEAD ON PRE-RINSE SPRAYER FURNISHED BY FIXTURE MANUFACTURER. PLUMBING CONTRACTOR SHALL FURNISH ORIGINAL SPRAY HEAD TO OWNER. EQUIPMENT FURNISHED WITH INTEGRAL BACKFLOW PREVENTER FOR CARBONATED WATER LINE. FILTERED WATER PIPING TO EQUIPMENT IS PROVIDED UNDER SEPARATE CONTRACT. PLUMBING CONTRACTOR SHALL PROVIDE INLINE FILTER PER MANUFACTURE ’S RECOMMENDATIONS. PROVIDE 36" FLEXIBLE GAS CONNECTION PROVIDE 48" FLEXIBLE GAS CONNECTION WITH QUICK DISCONNECT AND UPSTREAM GAS SHUT-OFF VALVE. ATTACH SINK TO WALL WITH CONTRACTOR-PROVIDED STAINLESS STEEL SLOTTED ROUND HEAD FASTENERS OR SHEET METAL SCREWS INSTALLED THROUGH HOLES DRILLED BY CONTRACTOR THROUGH TOP FLANGE OF SINK BACKSPLASH. FOR FRAMED WALLS, USE TWO EVENLY SPACED FASTENERS FOR PREP SINKS AND THREE EVENLY SPACED FASTENERS FOR 3-COMPARTMENT SINKS TO WALL STUDS. FOR SINKS INSTALLED ON COOLER PANEL WALLS, ATTACH SINKS TO COOLER PANEL OUTER SHEET METAL WITH SCREWS AT 12" CENTERS ALONG BACKSPLASH. SUPPORT INDIRECT DRAIN LINE FROM FLOOR AND INSTALL LINE AS CLOSE TO EQUIPMENT AS POSSIBLE. ISSUE BLOCK 1 PR#1 03/29/23 1 1. A. B. C. D. E. GENERAL INFORMATION (ALL FIXTURES): SUBSTITUTIONS NOT PERMITTED. REF SPECIFICATIONS FOR APPROVED MANUFACTURERS OF THE FOLLOWING TRIM AND ACCESSORIES: -P-TRAP WITH CLEANOUT PLUG: POLISHED CHROME-PLATED TUBULAR BRASS, 17 GAUGE WITH BRASS NUTS AND SLIP INSERTS. -SS BRAIDED WATER SUPPLY: FLEXIBLE BRAIDED STAINLESS STEEL (SS) OUTER SHEATHING WITH REINFORCED PVC INNER TUBING. -STOP VALVES: CHROME PLATED BRASS, QUARTER TURN ANGLE STOP VALVES. NOTES: FURNISH WITH 1/2" X 3 3/4" STAINLESS STEEL SIMPSON WEDGE-ALL WEDGE ANCHORS FOR ALL FlOOR MOUNTED FIXTURE CARRIERS. REFERENCE ARCHITECTURAL DRAWINGS FOR EWC2 ORIENTATION. COORDINATE WATER ROUGH-IN HEIGHT FROM MANUFACTURER'S INSTALLATION INSTRUCTIONS WITH GRAB BAR LOCATION. REF ARCH. USE SAME MANUFACTURER FOR UR1 AND UR2. FURNISH WITH LAVATORY DECK ASSEMBLY FIXTURE AND TRIM. TOILET PLUMBING FIXTURE SCHEDULE ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. REFER TO SPECIFICATIONS. MARK FIXTURE BRANCH SIZES (MIN) MANUFACTURER MODEL TRIM AND ACCESSORIES NOTESCW HW WASTE VENT WC2 WATER CLOSET ACCESSIBLE (FLOOR MOUNT) 1 1/4" 4" 2" [TOTO][AMERICAN STANDARD] [CT705ELN][3043.001.020] FLUSH VALVE: TOTO TET1LN32#CP-WR - 1.28 GPF SENSOR OPERATED SELF GENERATING POWER SYSTEM WITH MANUAL OVERRIDE AND VANDAL RESISTANT SET SCREW ESCUTCHEON AND STOP CAP. ELONGATED SEAT: BEMIS 1055SSC, MAINLINE ML 1055SSC CAST IRON FLOOR FLANGE: JONESPEC CF-2984-CI4, TYLER 2-252TS2, WITH "NO SEEP" WAX RING AND BRASS ANCHOR BOLTS. D 1