%COMBINED PLUMBING to PR-01 3-29-2302/01/18
02/01/18
02/01/18
9 8.8 8.6
C
B.6
DEMO
CD
CD
ETRCD
ETR
CD
ETR
CD
ETR
CD
ETR
14"x14" ETR
12"x12" ETR
8"Ø ETR
16"x20"
RAG
ETR
14"x20"
RTU-14
5 TON
2000
ETR
RAG
ETR
9 8.8 8.6
C
B.6
B
RTU-14
5 TON
2000
ETR
S-14
ETRCD
ETR
335
15.713
CD
ETR
335
15.713
CD
ETR
335
CD
ETR
335
15.713
RAG
ETR
1470
TG
ETR
TG
ETR
RAG
ETR
330
CD
ETR
430
15.713
AP
OFFICE
PICKUP
STORAGE
PHARMACY
TOILET
HEALTH
SERVICES
8"Ø
8"Ø ETR
CD
ETR
70
15.713
10"Ø ETR
42"x30"
TRANSFER
ETR
14"x14" ETR 12"x12" ETR
16"x20" ETR
10"Ø ETR
10"Ø ETR
CEILING RETURN GRILLE
SUPPLIED AND INSTALLED
BY PANEL MANUFACTURER
12"x12" FACE SIZE
8" ROUND NECK
SIMILAR TO TITUS TDC
150 CFM
CEILING DIFFUSER
SUPPLIED AND INSTALLED
BY PANEL MANUFACTURER
12"x12" FACE SIZE
8" ROUND NECK
SIMILAR TO TITUS TDC
150 TDC
FINAL DUCTWORK CONNECTION
TO PRE-INSTALLED DIFFUSER
BY GENERAL CONTRACTOR
6"Ø ETR
10"Ø ETR
10"Ø ETR
12"Ø ETR
15.713
1
M2
15.705
2
M2
INSTALL DAMPER
IN VERTICAL AT
24" MAX ABOVE
CEILING BALANCE
TO 1320 CFM
9 8.8 8.6
C
B.6
NEW SINK FURNISHED
BY MILL WORK MFG.
INSTALLED BY GC.
15.406
DISCONNECT/RECONNECT
EXISTING WATER FILTRATION
SYSTEM. WATER HEATER AS
NECESSARY.
PHARMACY
HEALTH
SERVICES
TOILET
EXIST WC
15.448
1 engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET:
DRAWN BY:
CHECKED BY:
PROTO CYCLE:
DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR
CONSTRUCTION
EXISTING CONDITIONS WERE TAKEN FROM
ORIGINAL DRAWINGS AND MAY NOT REFLECT
EXACT "AS-BUILT" CONDITIONS. CONTRACTOR
SHALL FIELD VERIFY ALL EXISTING CONDITIONS
PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR
SHALL CAREFULLY COORDINATE NEW WORK AND
DEMOLITION WITH ALL OTHER DISCIPLINES AND
EXISTING CONDITIONS.
EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING
A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND
SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE
TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES
NOT RELIEVE THE RESPONSIBILITY OF PERFORMING
THE WORK PROPERLY. NO ADDITIONAL
COMPENSATION SHALL BE ALLOWED BECAUSE OF
CONDITIONS THAT OCCUR DUE TO FAILURE TO
FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.
PROTO:176
MPH1
PHARMACY
MECHANICAL
AND
PLUMBING
PLANS
RGDYELM, WASHINGTON2022-0339YELM, WASHINGTON01/30/2301/30/23STORE NO: 3705-23217611/11/2217100 STATE ROUTE 507 SEJEE
1/8" = 1'-0"1 PHARMACY MECHANICAL DEMO PLAN
1/4" = 1'-0"2 PHARMACY MECHANICAL PLAN
1/4" = 1'-0"3 PHARMACY PLUMBING PLAN
KEYNOTES
15.406 PLUMBING CONTRACTOR TO MAKE ALL
NECESSARY DISCONNECTS AND RECONNECTS
OF PLUMBING FIXTURES BEING RELOCATED OR
NEW.
15.448 PLUMBING CONTRACTOR TO MAKE ALL
NECESSARY DISCONNECTS AND RECONNECTS
OF PLUMBING FIXTURES FOR FINISHES WORK.
PROVIDE CONTINUOUS SEALANT ALONG THE
EDGES OF RECONNECTED FIXTURES.
REFURBISH URINAL AND WC FLUSH VALVES TO
LIKE NEW OPERATING CONDITION.
15.705 CONNECT TO EXISTING SUPPLY/RETURN
DUCTWORK INDICATED.
15.713 REBALANCE AIR DEVICE TO CFM SHOWN.
REDISTRIBUTE AIR FROM EXISTING DUCTWORK
TO MATCH NEW CFM REQUIREMENTS.
ISSUE BLOCK
1 PR#1 03/29/23
1
SPECIALTY PLUMBING FIXTURE SCHEDULE
MARK FIXTURE MANUFACTURER MODEL FIXTURE DESCRIPTION
WPG WATER PRESSURE
GAUGE
AMETEK
TRERICE
WEISS INSTRUMENTS
656
D83LFSS
LF252
2.5 INCH STAINLESS STEEL CASE, ALL WETTED PARTS STAINLESS STEEL,
LIQUID FILLED, 1/4 INCH NPT CONNECTOR, 1.6% ACCURACY, 30" HG VAC
TO 100 PSI RANGE.
WHA WATER HAMMER
ARRESTOR
JOSAM
PRECISION PLUMBING PRODUCTS
WATTS
WILKINS
JAY R. SMITH
SIOUX CHIEF
MIFAB
SERIES 75000
STAINLESS STEEL #316 SERIES
SS SERIES
MODEL 1250XL SERIES
HYDROTROLS
HYDRA-RESTER
MWH
LEAD FREE CONFORM TO PDI WH-201, ANSI A112.26.1M, ASSE 1010.
FCV30 FLOW CONTROL
VALVE
BELL & GOSSETT
FLOW DESIGN
# CB LF "CIRCUIT SETTER PLUS"
ICSS050
LEAD FREE NAMEPLATE AND 1/2" VALVE BODY SIZE UNLESS SHOWN
OTHERWISE ON PLANS. SET AND BALANCE TO 0.25 GPM OR PROVIDE
0.25 GPM CARTRIDGE UNLESS SHOWN OTHERWISE ON PLANS AND PER
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
DCV DOUBLE-CHECK VALVE
BACKFLOW PREVENTER
(STAINLESS STEEL)
WATTS SS007QT-S ASSE 1015, 316 STAINLESS STEEL BODY, QUARTER TURN TEST COCKS,
QUARTER TURN, FULL PORT BALL VALVES AND STAINLESS STEEL
STRAINER.
---CHECK VALVES RED-WHITE
APOLLO
CRANE
WATTS
NIBCO
232
SERIES 61-100
119J
6
T-413
BRASS JACKET WITH PLASTIC VALVE ASSEMBLY
---DOUBLE-CHECK
VALVE BACKFLOW
PREVENTER
WATTS
BEECO
FEBCO
WILKINS
LF007QT OR LF709
FDC-LF
LF850
350XL OR 950XLT2
LEAD FREE, INCLUDE TWO INDEPENDENT-ACTING CHECK VALVES, TWO
SHUT-OFF VAVLES AND REQUIRED MEANS FOR TESTING FOR EACH
ASSEMBLY. MINIMUM 175 PSI WORKING PRESSURE.
---LOCKABLE
SHUT OFF
VALVES
RED-WHITE
APOLLO
CRANE
WATTS
5042
SERIES 70LF-100
LF-T-255
LFB-6000 OR LFB-6001
BRASS BALL VALVES WITH PLASTIC JACKETED LEVER TYPE HANDLE.
---REDUCED
PRESSURE
BACKFLOW
PREVENTER
WATTS
BEECO
FEBCO
WILKINS
LF009QT OR LF909
FRP-LF
LF860
375XL OR 975XL
LEAD FREE, PROVIDE STRAINER, SHUT-OFF VALVES AND TEST COCKS:
INSTALL DRAIN LINE WITH AIR GAP ASSEMBLY TO RECEPTOR APPROVED
BY AUTHORITY HAVING JURISDICTION. MINIMUM 175 PSI WORKING
PRESSURE.
---STRAINER WATTS
APOLLO
LF777SI
59-004-06
CAST BRONZE Y-STRAINER WITH BALL VALVE
---TRAP PRIMER
(MULTIPLE TRAPS)
PRECISION PLUMBING PRODUCTS
MIFAB
JOSAM
SIOUX CHIEF
PRIME RITE OR OREGON #1
M-500-NPB
88300
SERIES 695
LEAD FREE, PROVIDE ALL BRONZE PRIMER VALVE WTIH REMOVABLE
OPERATING PARTS, INTEGRAL VACUUM BREAKER, GASKETED ACCESS
COVER, AND MULTIPLE TRAP CAPABILITY
---TRAP PRIMER
(SINGLE TRAP)
PRECISION PLUMBING PRODUCTS
SIOUX CHIEF
PRIME-RITE OR OREGON #1
695
LEAD FREE, PROVIDE ALL BRONZE PRIMER VALVE WITH REMOVABLE
OPERATING PARTS, INTEGRAL VACUUM BREAKER, AND GASKETED
ACCESS COVER.
---VACUUM RELIEF
VALVE
WATTS LFN36-M1 LEAD FREE BRASS BODY. CSA/ANSI Z21.22
---VALVES RED-WHITE
APOLLO
CRANE
WATTS
NIBCO
5044AB OR 5049AB
SERIES 70 LF
LF9210 SERIES
LFFBV-3C OR LFFBVS-3C
FP-600-A-LF
LEAD FREE FULL PORT BRASS BALL VALVE WITH PLASTIC JACKETED
LEVER TYPE HANDLE.
GENERAL INFORMATION:
1. THIS SCHEDULE IS COMPREHENSIVE. ALL MARKS MAY OR MAY NOT BE USED.
---REDUCED
PRESSURE
BACKFLOW
PREVENTER
(STAINLESS STEEL)
WATTS SS009M3QT-S LEAD FREE, STAINLESS STEEL REDUCED PRESSURE ZONE ASSEMBLY.
FURNISHED WITH STAINLESS STEEL STRAINER, VANDAL RESISTANT
TEST COCKS, AND FULL PORT QUARTER TURN BALL VALVE SHUTOFFS.
INSTALL DRAIN LINE WITH AIR GAP ASSEMBLY TO RECEPTOR APPROVED
BY AUTHORITY HAVING JURISDICTION. MINIMUM 175 PSI WORKING
PRESSURE.
---BARRIER-TYPE TRAP
SEAL PROTECTION
SURE SEAL
JAY R SMITH
SS4009
2692
INLINE FLOOR DRAIN TRAP SEAL. ASSE 1072
FLOOR SLAB ON GRADE
LONG SWEEP ELBOW AT
END OR TURN OF RUN
DIRECTION
OF FLOW
COMBINATION WYE AND
EIGHTH BEND IN RUN.
ENTER TOP OF PIPE.
SAME SIZE AS SEWER
UP TO 4" MAXIMUM
MEMBRANE CLAMP
REFRIGERATED
CASE KICKPLATE
LOCATE FLOOR DRAIN WHERE SHOWN ON DIMENSIONED PLUMBING FLOOR PLAN
FLOOR DRAIN BODY WITH 2" OULET
PIPE INCREASER (IF REQUIRED)
NOTE:
PIPE INCREASER ONLY REQUIRED IF
CONNECTING WASTE LINE SIZE
SHOWN ON PLANS IS LARGER THAN
FLOOR DRAIN OUTLET SIZE
FLOOR
ALL DRAINS AND CLEANOUTS ON THE
SALES FLOOR SHALL BE FLUSH WITH
THE TOP OF CONCRETE SLAB; DO NOT
SLOPE FLOOR TO THESE DRAINS ACCESS TO CONDENSATE
DRAIN IS THRU REMOVABLE
PANEL ON FRONT OF
REFRIGERATED CASE
INSTALL OPEN HALF
OF GRATE UNDER
REFRIGERATED CASE
CASE CONDENSATE DRAIN,
END OPEN OVER DRAIN
WITH AIR GAP
REF REFRIGERATION
DEEP-SEAL P-TRAP
MIN. 4" WATER SEAL engineering consultants3333 East Battlefield Road, Suite 1000 | Springfield, MO 65804T: 417.881.0020 : www.rtmec.comSHEET:
DRAWN BY:
CHECKED BY:
PROTO CYCLE:
DOCUMENT DATE:CONSULTANTSSTIPULATION FOR REUSEPROTO:JOB NUMBER:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.NOT FOR
CONSTRUCTION
PROTO:176
P1
PLUMBING
DETAILS AND
SCHEDULES
RGDYELM, WASHINGTON2022-0339YELM, WASHINGTON01/30/2301/30/23STORE NO: 3705-23217611/11/2217100 STATE ROUTE 507 SEJEE
PLUMBING SYMBOLS
WALL CLEANOUT
HOSE BIBB
FREEZE PROOF WALL HYDRANT
YARD CLEANOUT
FLOOR SINK
ROOF DRAIN/OVERFLOW ROOF DRAIN
FLOOR DRAIN
T & P RELIEF VALVE
WATER HAMMER ARRESTOR
BACKFLOW PREVENTER
SHUT-OFF VALVE IN VERTICAL LINE
CHECK VALVE
PLUG VALVE
BALL VALVE
TEE - TURNED UP
TEE - TURNED DOWN
ELBOW - TURNED UP
ELBOW - TURNED DOWN
COMPRESSED AIR
NATURAL GAS
DOMESTIC HOT WATER
DOMESTIC HOT WATER RETURN
DOMESTIC COLD WATER
OVERFLOW ROOF DRAIN LINE
ROOF DRAIN LINE
OIL WASTE
GREASE WASTE
SANITARY SEWER
TEPID OR TEMPERED WATER
WATER METER
FILTERED WATER
STORM SEWER
IRRIGATION WATER
THERMOSTATIC MIXING VALVE
GAS COCK
GAS PRESSURE REGULATOR
PLUMBING VENT
REVERSE OSMOSIS WATER
CONDENSATE DRAIN
CONNECT TO EXISTING
EXISTING TO REMAIN
PLUMBING VACUUM
DEMO PIPE
AREA OF SLAB CUT
FLOW CONTROL VALVE
THERMOMETER
SS
GW
OW
ST
RD
ORD
IW
T
UNION
F
G
A
CD
RO
V
VAC
M
WHA
TMV
FD
FS
YCO
FPWH
HB
WCO
ETR
RD
VENT BELOW FLOORVBF
FLOOR CLEANOUTFCO
NTS2FLOOR CLEANOUT
NTS1REFRIGERATED CASE DRAIN
1.
2.
GENERAL INFORMATION (AS APPLICABLE):
REFER TO PLANS FOR DRAIN OUTLET SIZE.
AMSE LOAD CLASSIFICATIONS: LIGHT DUTY <2000 LBS, MEDIUM DUTY 2000 - 4999 LBS, HEAVY DUTY 5000 - 7499 LBS, EXTRA HEAVY DUTY 7500 - 9999 LBS.
CLEANOUT SCHEDULE
ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED B Y CONTRACTOR. REFER TO SPECIFICATIONS.
MARK MANUFACTURER MODEL DESCRIPTION
FCO1 ZURN
SIOUX CHIEF
MIFAB
JAY R. SMITH
JOSAM
WATTS
OATEY
Z1400
852
C1100
4231
55000
CO-200-RX-4
74000
CAST IRON OR PVC BODY, ROUND EXTRA HEAVY-DUTY CAST OR DUCTILE IRON TOP,
POLYPROPYLENE OR ABS PLUG, ADJUSTABLE TO FINISH SURFACE.
FLOOR DRAIN SCHEDULE
ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. REFER TO SPECIFICATIONS.
MARK MANUFACTURER MODEL DESCRIPTION
FD3 SIOUX CHIEF
JOSAM
860
FD-370
LIGHT DUTY PVC WITH 9" DIAMETER LOOSE SET PVC HALF GRATE
1.
A.
B.
C.
D.
E.
F.
G.
GENERAL INFORMATION (ALL FIXTURES):
SUBSTITUTIONS NOT PERMITTED. REF SPECIFICATIONS FOR APPROVED MANUFACTURERS OF THE FOLLOWING TRIM AND ACCESSORIES:
-P-TRAP WITH CLEANOUT PLUG AND SINK CONTINUOUS WASTES: POLISHED CHROME-PLATED TUBULAR BRASS, 17 GAUGE WITH BRASS NUTS AND SLIP INSERTS.
-SS BRAIDED WATER SUPPLY: FLEXIBLE BRAIDED STAINLESS STEEL (SS) OUTER SHEATHING WITH REINFORCED PVC INNER TUBING.
-STOP VALVES: CHROME PLATED BRASS, QUARTER TURN ANGLE STOP VALVES.
NOTES:
MOUNT EYEWASH 36" AFF TO TOP OF HEAD SPRAY.
INSTALL MOP SINK FAUCET AT 32" AFF AND LOCATE TWO MOP HANGER BRACKETS SIDE BY SIDE NEAR MOP SINK.
FURNISH WITH ZURN TMV (MODEL ZW3870XLT) UNLESS SERVED WITH TEMPERED WATER OR NOTED OTHERWISE ON PLUMBING DRAWINGS. SET AT 120° F.
TRIM WITH OFFSET TAILPIECE, 5/8" ARMAFLEX INSULATION ON EXPOSED HOT WATER AND DRAIN LINES. HOLD ALL EXPOSED PIPING HIGH AS POSSIBLE.
REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR ACTUAL ROUGH-IN HEIGHT REQUIREMENTS.
FURNISH WITH 1/2" X 2 1/2" STAINLESS STEEL SIMPSON WEDGE-ALL ANCHORS FOR ALL FIXTURES.
CONTRACTOR TO COORDINATE THE REQUIRED CARRIER PRIOR TO ORDERING.
PLUMBING FIXTURE SCHEDULE
ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. REFER TO SPECIFICATIONS.
MARK FIXTURE
BRANCH SIZES (MIN)
MANUFACTURER MODEL DESCRIPTION, TRIM AND ACCESSORIES NOTESCW HW WASTE VENT
SS1 SERVICE SINK
(TERRAZZO)
24" x 24" x 12"
3/4" 3/4" 3" 2" STERN-WILLIAMS
FIAT
ACORN
SB-800
TSB-200
TSH-24-SSC-LB
CHROME PLATED FAUCET WITH INTEGRAL CHECK VALVES, HOSE, BRACKET (MOUNT
DIRECTLY ABOVE WALL GUARD), MOP HANGER (60"AFF).
FAUCET: CHICAGO 897-CP (DISCARD STANDARD SUPPLY ARMS & CONNECT (2) GCJKCP
SUPPLY ARMS USING (2) 897-020JKRCF ADAPTERS), ZURN Z843M1-CS, T&S BRASS
B-0665-BSTP W/ ETERNA CARTRIDGES & SPRING CHECKS.
HOSE/BRACKET: STERN WILLIAMS T-35, FIAT 832-AA, ACORN KH36.
MOP HANGER: STERN WILLIAMS T-40, FIAT 889-CC, ACORN KMH.
B
ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. REFER TO SPECIFICATIONS.
GROCERY PLUMBING EQUIPMENT CONNECTION SCHEDULE
MARK FIXTURE
BRANCH SIZES (MIN)
ROUGH-IN REQUIREMENTS NOTESRO CW HW WASTE VENT GAS
SS004R WALL MOUNTED HAND SINK WITH RH
SPLASH
1/2" 1/2" 1 1/2" 1 1/4" WATER: 18" AFF; WASTE: 18" AFF B, C, F, J, N
1.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
W.
X.
Y.
Z.
GENERAL INFORMATION (ALL EQUIPMENT):
EQUIPMENT AND TRIM FURNISHED BY OWNER. ROUGH-IN AND FINAL CONNECTIONS BY PLUMBING CONTRACTOR, UNLESS NOTED OTHERWISE.
NOTES:
PROVIDE SHUT-OFF VALVES.
PROVIDE P-TRAP WITH CLEANOUT PLUG AND ESCUTCHEON.
PROVIDE CHROME PLATED ANGLE SUPPLY, FLEXIBLE RISER, AND WHEEL HANDLE WITH ESCUTCHEON.
SINK FAUCETS PROVIDED WITH INTEGRAL CHECK VALVES.
PROVIDE FULL-SIZE DRAIN LINE FROM EQUIPMENT, END OPEN OVER RECEPTOR WITH 2" AIR GAP.
IF PLUMBING PLAN SHOWS THE SINK INDIRECTLY CONNECTED TO FLOOR SINK, THEN WASTE ROUGH-IN HEIGHT AND VENT SIZE AND NOTE B DO NOT APPLY.
PROVIDE DOUBLE CHECK BACKFLOW PREVENTER ON WATER SUPPLY. PROVIDE FEMALE NPT VALVE DOWNSTREAM OF BACKFLOW PREVENTER FOR CONNECTION BY OTHERS.
PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL FLEXIBLE WATER PIPING AND QUICK DISCONNECT TO EQUIPMENT.
PROVIDE STAINLESS STEEL DOUBLE CHECK BACKFLOW PREVENTER EQUAL TO WATTS SS007QT-S ON RO WATER SUPPLY. PROVIDE PEX TUBING ON DOWNSTREAM SIDE OF
BACKFLOW PREVENTER.
INSTALL THERMOSTATIC MIXING VALVE FURNISHED WITH SINK WITH HARD-PIPED CONNECTIONS TO ANGLE STOPS AND FLEXIBLE CONNECTIONS BETWEEN THERMOSTATIC MIXING
VALVE, FOOT PEDAL (PEDESTAL HAND SINK) OR KNEE LEVER (WALL MOUNTED HAND SINK) OR WRIST BLADE LEVERS (ADA WALL MOUNTED HAND SINK) AND SINK. SET AT 105°F.
IF RO WATER IS NOT AVAILABLE, PROVIDE INDIVIDUAL WATER FILTER PACKS AS REQUIRED BY WALMART CONSTRUCTION MANAGER.
PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL EXPOSED DOUBLE CHECK BACKFLOW PREVENTER (WATTS #007 OR EQUAL).
PROVIDE COLD WATER INJECTOR OPTION IF ON PLAN OR REQUIRED BY AHJ. REQUIRES 1/2" CW LINE AT FLOOR DRAIN. MODEL #CWI-500.
REFER TO ARCHITECTURAL DRAWINGS FOR HAND SINK LEFT (L) AND RIGHT (R) DESIGNATIONS WHICH INDICATE INTEGRAL SPLASHGUARD LOCATIONS OR HAND SINK (H) FOR ADA
DESIGNATION.
REFRIGERATION CONTRACTOR TO INSTALL MISTING SYSTEM. SUPPLY SIDE ROUGH-IN AND FINAL CONNECTION BY PLUMBING CONTRACTOR.
RO VENDOR SHALL BE RESPONSIBLE FOR LOCATIONS OF DRINK DISPENSER AND WATER FILTRATION EQUIPMENT AND ALL FINAL CONNECTIONS.
PROVIDE 1 1/2" P-TRAP AT 12"AFF WITH 1 1/2" TO 3/4" REDUCER FOR CONNECTION TO RO WATER DISPENSER DRAIN.
PROVIDE 3/4" I.D. FEMALE FITTING AND SHUT-OFF FOR RO DISPENSER WATER CONNECTION AT 18"AFF.
INSTALL 1.2 GPM SPRAY HEAD ON PRE-RINSE SPRAYER FURNISHED BY FIXTURE MANUFACTURER. PLUMBING CONTRACTOR SHALL FURNISH ORIGINAL SPRAY HEAD TO OWNER.
EQUIPMENT FURNISHED WITH INTEGRAL BACKFLOW PREVENTER FOR CARBONATED WATER LINE.
FILTERED WATER PIPING TO EQUIPMENT IS PROVIDED UNDER SEPARATE CONTRACT.
PLUMBING CONTRACTOR SHALL PROVIDE INLINE FILTER PER MANUFACTURE ’S RECOMMENDATIONS.
PROVIDE 36" FLEXIBLE GAS CONNECTION
PROVIDE 48" FLEXIBLE GAS CONNECTION WITH QUICK DISCONNECT AND UPSTREAM GAS SHUT-OFF VALVE.
ATTACH SINK TO WALL WITH CONTRACTOR-PROVIDED STAINLESS STEEL SLOTTED ROUND HEAD FASTENERS OR SHEET METAL SCREWS INSTALLED THROUGH HOLES DRILLED BY
CONTRACTOR THROUGH TOP FLANGE OF SINK BACKSPLASH. FOR FRAMED WALLS, USE TWO EVENLY SPACED FASTENERS FOR PREP SINKS AND THREE EVENLY SPACED
FASTENERS FOR 3-COMPARTMENT SINKS TO WALL STUDS. FOR SINKS INSTALLED ON COOLER PANEL WALLS, ATTACH SINKS TO COOLER PANEL OUTER SHEET METAL WITH SCREWS
AT 12" CENTERS ALONG BACKSPLASH.
SUPPORT INDIRECT DRAIN LINE FROM FLOOR AND INSTALL LINE AS CLOSE TO EQUIPMENT AS POSSIBLE.
ISSUE BLOCK
1 PR#1 03/29/23
1
1.
A.
B.
C.
D.
E.
GENERAL INFORMATION (ALL FIXTURES):
SUBSTITUTIONS NOT PERMITTED. REF SPECIFICATIONS FOR APPROVED MANUFACTURERS OF THE FOLLOWING TRIM AND ACCESSORIES:
-P-TRAP WITH CLEANOUT PLUG: POLISHED CHROME-PLATED TUBULAR BRASS, 17 GAUGE WITH BRASS NUTS AND SLIP INSERTS.
-SS BRAIDED WATER SUPPLY: FLEXIBLE BRAIDED STAINLESS STEEL (SS) OUTER SHEATHING WITH REINFORCED PVC INNER TUBING.
-STOP VALVES: CHROME PLATED BRASS, QUARTER TURN ANGLE STOP VALVES.
NOTES:
FURNISH WITH 1/2" X 3 3/4" STAINLESS STEEL SIMPSON WEDGE-ALL WEDGE ANCHORS FOR ALL FlOOR MOUNTED FIXTURE CARRIERS.
REFERENCE ARCHITECTURAL DRAWINGS FOR EWC2 ORIENTATION.
COORDINATE WATER ROUGH-IN HEIGHT FROM MANUFACTURER'S INSTALLATION INSTRUCTIONS WITH GRAB BAR LOCATION. REF ARCH.
USE SAME MANUFACTURER FOR UR1 AND UR2.
FURNISH WITH LAVATORY DECK ASSEMBLY FIXTURE AND TRIM.
TOILET PLUMBING FIXTURE SCHEDULE
ALL PRODUCTS ON THIS SCHEDULE ARE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR. REFER TO SPECIFICATIONS.
MARK FIXTURE
BRANCH SIZES (MIN)
MANUFACTURER MODEL TRIM AND ACCESSORIES NOTESCW HW WASTE VENT
WC2 WATER CLOSET
ACCESSIBLE (FLOOR
MOUNT)
1 1/4" 4" 2" [TOTO][AMERICAN
STANDARD]
[CT705ELN][3043.001.020] FLUSH VALVE: TOTO TET1LN32#CP-WR - 1.28 GPF SENSOR OPERATED SELF GENERATING POWER SYSTEM WITH MANUAL OVERRIDE AND
VANDAL RESISTANT SET SCREW ESCUTCHEON AND STOP CAP. ELONGATED SEAT: BEMIS 1055SSC, MAINLINE ML 1055SSC CAST IRON
FLOOR FLANGE: JONESPEC CF-2984-CI4, TYLER 2-252TS2, WITH "NO SEEP" WAX RING AND BRASS ANCHOR BOLTS.
D
1