1311l Yelm WRF FAD resubmittal updates 6-28-23
SCOPE OF WORK INSTALL NEW SILENT KNIGHT SK -6808 ADDRESSABLE FIRE ALARM PANEL IN GROUP H-4 OCCUPANCY FOR ADDITIONAL FIRE DETECTION COVERAGE IN 4 BUILDINGS. PANEL TO TIE INTO EXISTING FIRE PANEL. PROVIDE FIRE ALARM VISUAL AND AUDIBLE NOTIFICATION THROUGHOUT BUILDINGS. PROVIDE PROTECTO WIRE AND PULL STATIONS THROUGHOUT BUILDINGS. BUILDINGS ARE NOT SPRINKLED. DESIGNED IN ACCORDANCE WITH: NFPA 72 2019 NEC 2020 IBC 2018 INSTALLATION NOTES: 1) PRIOR TO CALLING FOR INSPECTION, THE INSTALLER SHALL PROVIDE DOCUMENTATION TO THE LOCAL AHJ STATING THAT THE SYSTEM HAS BEEN INSTALLED, TESTED, EVALUATED AND CONFIRMED TO BE IN ACCORDANCE WITH ALL GOVERNING CODES AND THE APPROVED PLANS. THE FIRE ALARM INSTALLER SYSTEM INSTALLER SHALL COMPLETE AN NFPA 72 RECORD OF COMPLETION (NFPA 72 10.18.2.1). THE RECORD OF COMPLETION SHALL BE PROVIDED TO THE AHJ INSPECTOR AT THE TIME OF THE INSPECTION (NFPA 72 10.18.2.1.2.4). 2) INSTRUCTIONS FOR OPERATING, TESTING, AND MAINTENANCE OF THE SYSTEM ALONG WITH RECORD DRAWINGS OTHERWISE REFERRED TO "AS-BUILTS" AND EQUIPMENT SPECIFICATIONS SHALL BE PROVIDED AT AN APPROVED LOCATION. 3) ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURE'S LISTING AND THE AUTHORITY HAVE JURISDICTION (NFPA 72 10.14.2.1). LABEL ALL DEVICE LOCATIONS. 4) FACP AND ALL REMOTE POWER SUPPLIES REQUIRE A DEDICATED 120VAV - 20AMP CIRCUIT. A NOTICE PLACED IN THE FACP SHALL DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER TO THE SYSTEM (NFPA 72 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT. 5) WALL MOUNTED STROBES SHALL BE PLACED 80" MINIMUM TO 96" MAXIMUM ABOVE FLOOR LEVEL (NFPA 72 18.5.4.1 & 2). WALL MOUNTED STROBES SHALL BE SIZED IN ACCORDANCE WITH (NFPA 72 TABLE 18.5.4.3.1(A). CEILING MOUNTED STROBES SHALL BE PLACED AND SIZED IN ACCORDANCE WITH (NFPA 72 TABLE 18.5.4.3.1(B). 6) WHEN MORE THAN TWO NOTIFICATION APPLIANCES ARE VISIBLE AT THE SAME TIME IN THE SAME ROOM OR ADJACENT SPACE OR THE FIELD OF VIEW THE FLASH OF THE STROBES SHALL BE SYNCHRONIZED (NFPA 72 18.5.4.3. (3) AND (4). 7) PULL STATIONS SHALL BE PLACED BETWEEN 42 AND 48 INCHES ABOVE FLOOR LEVEL. DEVICES SHALL BE RED IN COLOR (ICC A117.1 309 AND NFPA 72 17.14.5). 8) CENTER SMOKE DETECTORS IN CORRIDORS WITH CEILING LIGHTING AND THE FA STROBES. SMOKE DETECTORS IN CORRIDORS ARE TO BE SPACED PER NFPA 72 17.6.3.1 (H) AND 17.7.3.2.4.2 (4). 9) AUDIBILITY REQUIREMENTS: A SOUND LEVEL OF 75dbA or 15dbA OVER AMBIENT SHALL BE REACHED IN ALL AREAS PROVIDED WITH FIRE ALARM DEVICES PER SPECIFICATION AND NFPA-72. 10) SET STROBE CANDELA OUTPUT AS SHOWN ON PLANS. SET HORN TO MED SETTING 11) FIRE ALARM CIRCUITS TO BE INSTALLED, SECURED, AND TERMINATED IN ACCORDANCE WITH NEC, NFPA 72, AND LOCAL AHJ REQUIREMENTS AND STANDARDS. 12) NOTIFY E -SQUARED SYSTEMS OF ANY DESIGN QUESTIONS OR CHANGES PRIOR TO INSTALLATION OR FABRICATION. COMPARE DRAWINGS WITH CURRENT CONTRACT DRAWINGS PRIOR TO INSTALLATION. 13) ANY ALTERATIONS OR VARIATIONS FROM THE DRAWINGS SHOULD BE APPROVED PRIOR TO PROCEEDING AND DOCUMENTED ON THE AS -BUILT DRAWINGS. VERIFY DEVICE LOCATIONS PRIOR TO INSTALLATION. 14) REFERENCE FACTORY INSTRUCTION MANUALS CURING INSTALLATION OF FIRE CONTROL EQUIPMENT. 15) DETECTORS SHALL NOT BE MOUNTED IN A DIRECT AIR STREAM. DO NOT INSTALL DETECTORS WITH IN 3'-0" OF AIR DIFFUSERS. 16) US ONLY U.L. LISTED DEVICES. 17) DO NOT INSTALL DETECTOR HEADS UNTIL FINAL CLEANING HAS BEEN PERFORMED. 18) FIELD DETERMINE INTERFACE REQUIREMENTS AND LOCATIONS OF EQUIPMENT SUPPLIED BY OTHER TRADES. (I.E. SPRINKLER DEVICES, HVAC UNITS, FIRE DAMPERS, ELEVATOR CONTROLS, & FAN CONTROLS.) 19) NOTIFY E -SQUARED A MIN. OF 1 WEEK PRIOR TO THE INSTALLATION OF ALL WIRING, DEVICES, AND POWER, FOR SCHEDULING OF SYSTEM CHECK OUT AND PROGRAMMING. E -SQUARED REQUIRES A MIN. OF 2 DAYS ON SITE FOR CHECKS PRIOR TO SCHEDULING A FIRE ALARM FINAL. LARGER SYSTEMS WILL REQUIRE MORE TIME. FAILURE TO HAVE WORK COMPLETED WILL REQUIRE RESCHEDULING AND ADDITIONAL COSTS. 9 r :I w d I LTA &TiTj :19 913 NORTHERN PACIFIC RD SE YELM, WA 98597 FIRE ALARM SYSTEM ELECTRICAL NOTES: 1) INSTALLATION SHALL COMPLY WITH NFPA 70, PARTICULARLY ARTICLE 760, AND SHALL ALSO COMPLY WITH NFPA 72, AND ALL LOCAL ELECTRICAL CODES AND LOCAL JURISDICTION REQUIREMENTS. 2) CONDUIT INDICATED ON PRINTS IS DIAGRAMMATIC AND MAY BE REROUTED PER FIELD REQUIREMENTS. 3) AC POWER SHALL NOT OCCUPY THE SAME CONDUIT AS FIRE PROTECTION CIRCUITS (MOST FIRE DETECTION CKT'S ARE NEC CLASS 3) 4) ALL SLC LOOP WIRING SHALL BE MINIMUM 2 CONDUCTOR #16, UNSHIELDED, LOW/MID CAPACITANCE FIRE ALARM CABLE OF THE PROPER RISER AND/OR PLENUM TYPE. SEE WIRE LEGEND FOR PROJECT SPECIFIC TYPE/GAUGE. 5) CONVENTIONAL FIRE DETECTION INITIATING DEVICE CIRCUITS OR NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PARALLEL BRANCHED (TEE TAPPED) TO ENSURE SUPERVISION OF WIRING. ADDRESSABLE CLASS "A" FIRE DETECTION SIGNALING LINE CIRCUITS (SLC) SHALL NOT BE PARALLEL BRANCHED (TEE TAPPED) TO ENSURE SUPERVISION OF WIRING. 6) OBSERVE POLARITY OF ALL FIRE DETECTION WIRING. POLARITY SHALL BE MAINTAINED THROUGHOUT ENTIRE SYSTEM; WIRE SHALL BE MARKED AND IDENTIFIED WHERE SPLICED, AND AT ANY JUNCTION BOXES. 7) THE FIRE ALARM PANEL GROUND SHALL BE A SEPARATE CONTINUOUS GROUND WIRE BACK TO THE SOURCE GROUND; CONDUIT GROUND IS NOT ACCEPTABLE PER MANUFACTURER'S SPECIFICATIONS. 8) ALL FIELD WIRING SHALL BE CHECKED FOR SHORTS, GROUNDS, & PROPER END OF LINE RESISTOR (ELR) VALUES BEFORE SCHEDULING E -SQUARED FOR SYSTEM CHECK OUT. DOCUMENT CIRCUIT READINGS AND PRESENT TO E -SQUARED TECHNICIAN UPON INITIAL ARRIVAL ON SITE. PROVIDE E -SQUARED A MIN. OF 1 WEEK NOTICE PRIOR TO CHECK OUT. 9) FIRE ALARM PANEL, AND ANY OTHER FIRE DETECTION EQUIPMENT REQUIRING 120VAC, SHALL BE SUPPLIED BY A DEDICATED CIRCUIT BREAKER OTHER (NON -FIRE DETECTION) EQUIPMENT SHALL NOT SHARE THE FIRE ALARM CIRCUIT(S). THIS BREAKER SHALL BE PROVIDED WITH A BREAKER LOCK -OUT FOR ALL FIRE ALARM EQUIPMENT AND MARKED "FIRE ALARM CIRCUIT CONTROL". 120VAC POWER BY OTHERS. 10) POWER SHALL NOT BE APPLIED TO THE FIRE ALARM PANEL UNLESS A REPRESENTATIVE FROM E -SQUARED IS PRESENT. 11) WIRE NUTS ARE NOT ALLOWED. ALL SPLICES ARE TO BE TERMINATED ON TERMINAL STRIPS. (APPLICABLE TO MILITARY INSTALLATIONS ONLY) 12) ALL SLC, NOTIFICATION, AND SPEAKER WIRING SHALL BE STYLE 6 (CLASS A). NO OUTPUT CIRCUITS, FROM FCP, OR RETURN CIRCUITS SHALL BE RUN IN THE SAME CONDUIT. VERTICAL SEPARATION OF CONDUITS SHALL BE AT LEAST 1 FOOT AND HORIZONTAL SEPARATION SHALL BE AT LEAST 4 FEET. 13) ELECTRICAL FINAL SHALL BE COMPLETED PRIOR TO SCHEDULING E -SQUARED FOR CHECK-OUT, UNLESS REQUIRED OTHERWISE BY AHJ. SYSTEM INPUT SYM QTY MODEL NUMBER DESCRIPTION MANUFACTURER 1� MOUNTING CIRCUIT TYPE Q GAUGE COLOR 1 ADDRESSABLE CIRCUIT FPLP A(1,2,3 .... 16 2 RED 1 FACP 1 6808 ADDRESSABLE FIRE ALARM PANEL SILENT KNIGHT SURFACE MOUNT OfOf w 6'-0" 2 BPS 1 HPF-PS6B 6AMP 5 CIRCUT POWER SUPPLY FCI SURFACE MOUNT FPLP C 14/2 3 :D L [if w DURA12-8 :3 a a =( & BPS RED 4 FM _BB1 1 M13132 2 BOARD CABINET FCI SURFACE MOUNT 7 ADDRESSABLE CIRCUIT UG RATED ~ m o� L<E o� Qzo 0 wv o w MBB2 12/2 6 JACKET 9 CONVENTIONAL CIRCUIT UG RATED AQUASEAL Bg 12/2 BLACK pfif d J p O w ~O w 8 ® 1 SK -PHOTO PHOTOELECTRIC SMOKE DET. ADDRESSABLE SILENT KNIGHT ON BASE O z �v~i �o a� B300-6 6" SENSOR BASE SILENT KNIGHT 4" SQ 1.5" DEEP W/S.G. MUDRING 10 ❑F 8 SK -PULL -DA v SILENT KNIGHT ¢� c�ac� W/S.G. MUDRING 11 ❑M 7 SK -MONITOR SINGLE POINT MONITOR MODULE, ADDRESSABLE SILENT KNIGHT 4" SQ 1.5" DEEP W/S.G. MUDRING 12 ALARM @ FCP 1 SK -RELAY RELAY MODULE, ADDRESSABLE SILENT KNIGHT X X X MUDRING 13 0 4 M50OX ISOLATOR MODULE SILENT KNIGHT 4" SQ 1.5" DEEP W/S.G. TROUBLE @ FCP X X X X SINGLE CONTACT 155° HEAT DET. WIRE PROTECTO WIRE MONITOR MODULE CONTACTS 15 OH,T 1 302-EPM-135 135° THERMAL PROBE, R.O.R., EXPLOSION PROOF HONEYWELL INTO 1/2" THREADED FEMALE 16 0 SUPV. © FCP 5603 135° HEAT DETECTOR, CONVENTIONAL SYSTEM SENSOR 4" SQ 1.5" DEEP W/3-0 MUDRING 18 NOTIFICATION DEVICES 19 wp� 4 P2RK RED WALL MOUNTED HORN/STROBE WP SYSTEM SENSOR WP :�D ACTIVATE FIRE 20 C 4 X X X 4" SQ 1.5" DEEP W/S.G. MUDRING 21 5 P2RL RED WALL MOUNTED HORN/STROBE a- HORN/STROBES SQ 1.5" DEEP W/S.G. MUDRING 22 23 24 MOUNT MANUAL PULL STATIONS SO ACTUATION LEVER IS AT +48" ABOVE FINISHED FLOOR. MOUNT HORN/STROBES AND STROBES WITH BOTTOM OF STROBE AT +80" ABOVE FINISHED FLOOR. ENTIRE LENS MUST BE BETWEEN 80" & 96" AND NO LESS THAN 6" BELOW CLG. MOUNT ALL PANELS WITH TOP AT 6'-0" AFF. SET STROBE CANDELA OUTPUT AS SHOWN ON PLANS. SET INTERIOR HORNS TO LOW SETTING, EXTERIOR HORNS TO HIGH SETTING. ACTIVATE FIRE ADDITIONAL MOUNTING OPTIONS DATA SHEETS, PROVIDED. 0 WATERFLOW BELL ::5 TRANSMIT GEN ALM X X X LLJ TO MONITORING C") TRANSMIT WF ALM Cr) TO MONITORING TRANSMIT TROUBLE X X X X TO MONITORING TRANSMIT SUPERVISORY TO MONITORING ACTIVATE UNIT X X X HORN/STROBESLI DESISNER OF RECORD: SAND�FER DEER MCET ( #129796 ADDED SPOT DETECTION IN BIOSOLIDS ELECTRICAL AND STORAGE AREAS ADDED RELAY AND INPUT MODULES FOR CONTROL BUIDLING FACP INTERFACE BILL OF MATERIALS (BOM) ITEM SYM QTY MODEL NUMBER DESCRIPTION MANUFACTURER 1� MOUNTING CIRCUIT TYPE CABLE TYPE NO. GAUGE COLOR 1 ADDRESSABLE CIRCUIT FPLP A(1,2,3 .... 16 2 RED 1 FACP 1 6808 ADDRESSABLE FIRE ALARM PANEL SILENT KNIGHT SURFACE MOUNT TOP AT 6'-0" 2 BPS 1 HPF-PS6B 6AMP 5 CIRCUT POWER SUPPLY FCI SURFACE MOUNT FPLP C 14/2 3 RED 4 DURA12-8 12V-8AH BATTERY DURACELL MOUNTS IN FACP & BPS RED 4 FM _BB1 1 M13132 2 BOARD CABINET FCI SURFACE MOUNT 7 ADDRESSABLE CIRCUIT UG RATED 5 FIS 1 ISO -6 6 INPUT ISOLATOR MODULE FCI IN MBB2 12/2 6 JACKET 9 CONVENTIONAL CIRCUIT UG RATED AQUASEAL Bg 12/2 BLACK JACKET 7 INITIATING DEVICES 8 ® 1 SK -PHOTO PHOTOELECTRIC SMOKE DET. ADDRESSABLE SILENT KNIGHT ON BASE 9 1 B300-6 6" SENSOR BASE SILENT KNIGHT 4" SQ 1.5" DEEP W/S.G. MUDRING 10 ❑F 8 SK -PULL -DA MANUAL PULL STATION DUAL ACT.- ADDRESSABLE SILENT KNIGHT 4" SQ 1.5" DEEP W/S.G. MUDRING 11 ❑M 7 SK -MONITOR SINGLE POINT MONITOR MODULE, ADDRESSABLE SILENT KNIGHT 4" SQ 1.5" DEEP W/S.G. MUDRING 12 R 1 SK -RELAY RELAY MODULE, ADDRESSABLE SILENT KNIGHT 4" SQ 1.5" DEEP W S. G. MUDRING 13 0 4 M50OX ISOLATOR MODULE SILENT KNIGHT 4" SQ 1.5" DEEP W/S.G. MUDRING 14 P 500' PHSC-155-XCR SINGLE CONTACT 155° HEAT DET. WIRE PROTECTO WIRE MONITOR MODULE CONTACTS 15 OH,T 1 302-EPM-135 135° THERMAL PROBE, R.O.R., EXPLOSION PROOF HONEYWELL INTO 1/2" THREADED FEMALE 16 0 1 5603 135° HEAT DETECTOR, CONVENTIONAL SYSTEM SENSOR 4" SQ 1.5" DEEP W/3-0 MUDRING 18 NOTIFICATION DEVICES 19 wp� 4 P2RK RED WALL MOUNTED HORN/STROBE WP SYSTEM SENSOR WP BACK BOX 20 C 4 PC2RL RED CEILING MOUNTED HORN/STROBE SYSTEM SENSOR 4" SQ 1.5" DEEP W/S.G. MUDRING 21 5 P2RL RED WALL MOUNTED HORN/STROBE SYSTEM SENSOR 4" SQ 1.5" DEEP W/S.G. MUDRING 22 23 24 MOUNT MANUAL PULL STATIONS SO ACTUATION LEVER IS AT +48" ABOVE FINISHED FLOOR. MOUNT HORN/STROBES AND STROBES WITH BOTTOM OF STROBE AT +80" ABOVE FINISHED FLOOR. ENTIRE LENS MUST BE BETWEEN 80" & 96" AND NO LESS THAN 6" BELOW CLG. MOUNT ALL PANELS WITH TOP AT 6'-0" AFF. SET STROBE CANDELA OUTPUT AS SHOWN ON PLANS. SET INTERIOR HORNS TO LOW SETTING, EXTERIOR HORNS TO HIGH SETTING. FOR SEE ADDITIONAL MOUNTING OPTIONS DATA SHEETS, PROVIDED. ALL CABLES SHOULD BE 16-12AWG SOLID, MID CAPACITANCE, PLENUM AS SHOWN(EXCEPT U.G.), NON—SHIELDED. ALL CONDUITS SHOULD BE 3/4" MINIMUM/OR AS REQUIRED BY NEC 70 UNLESS OTHERWISE NOTED ON PLANS. INDOOR CABLE REPRESENTS WINDI CITY WIRE PART NUMBERS. UNDERGROUND (U.G.) CABLE REPRESENTS WEST PENN PART NUMBER. cn z Li 12 0 C-) w cf,w _ Q 0 J � Q o w �W Q 111 cjoe X o w o� w Q z � cn Q cn a - LLJ 0 I W c J �y Q LJ— cvn L� JOB # 1311 C FA -01 CABLE/CONDUCTOR ST CIRCUIT TYPE CABLE TYPE NO. GAUGE COLOR 1 ADDRESSABLE CIRCUIT FPLP A(1,2,3 .... 16 2 RED JACKET 2 NOTIFICATION APPLIANCE CIRCUIT FPLP N(1,2,3 .... 14 2 RED JACKET 3 CONVENTIONAL CIRCUIT FPLP B 16/2 RED JACKET 4 24VDC POWER FPLP C 14/2 RED JACKET 5 PROTECTO WIRE PHSC—XCR FPLP P(1,2,3....) 16 2 RED JACKET 6 BOOSTER POWER SUPPLY TRIGGER CIRCUIT FPLP T 1 ,2,3,... 14 2 RED JACKET 7 ADDRESSABLE CIRCUIT UG RATED AQUASEAL A 1 ,2,3,... 12/2 BLACK — JACKET 8 NOTIFICATION APPLIANCE CIRCUIT UG RATED AQUASEAL N 1 ,2,3,... 12/2 BLACK JACKET 9 CONVENTIONAL CIRCUIT UG RATED AQUASEAL Bg 12/2 BLACK JACKET ALL CABLES SHOULD BE 16-12AWG SOLID, MID CAPACITANCE, PLENUM AS SHOWN(EXCEPT U.G.), NON—SHIELDED. ALL CONDUITS SHOULD BE 3/4" MINIMUM/OR AS REQUIRED BY NEC 70 UNLESS OTHERWISE NOTED ON PLANS. INDOOR CABLE REPRESENTS WINDI CITY WIRE PART NUMBERS. UNDERGROUND (U.G.) CABLE REPRESENTS WEST PENN PART NUMBER. cn z Li 12 0 C-) w cf,w _ Q 0 J � Q o w �W Q 111 cjoe X o w o� w Q z � cn Q cn a - LLJ 0 I W c J �y Q LJ— cvn L� JOB # 1311 C FA -01 SiTE SCALENTS M A P NORTH 0F RECORD: DEER ry (—AS) U) Z W O U W (f) N (n W Q p J � Q � O W W> 0_ W Q ly- X_ O � W p � W Q p cy (� Q Cl) d Z I = p n z cn M M N N ~r) 00 Q N N 0 I I cD JOB # 1311 C FA -02 2OF9 00 I- C) ao J Q N J a N D W J ~ J X cn FEED FORWARD i cn N3 -3 AREA 300 DEQGNER OE RECORD° oa- a Q 75CD N t-WP J:�Yj F"< -6-2N2 SAND�FER DEER 4 w X F TO Ln o L97M12 °\ N3-2 EOL N3 CENTRIFUGE PUMP STATION MCET V(FAS)0 a_ 15CD \o� FL97M11 N3-1 15CD N3 A2(g),N4(g) 29/96 Az A2,N3 2A2(g),N3(g) � a 2A2 x IN 1" CONDUIT M G P5 L97M10 A2,N3 LLJ / O —MBR GALLERY ® cn z co Q 402 w 0 U Q MRB 2 TANK MRB 1 TANK cn w w ( ON OCCUPIED)( ON OCCUPIE Q / J Q � U 0W �W <� ANOXIC Q 0 o x cy- TANKS o� Q c� ccnQ z=o oZ� WN F --I N I QN � I N I j o W O 7 x J A2(g),N3,4(g) A2,N3, 44 L97MO9 IN 1" CONDUIT P4 P4 Al W L97M08 F u% N2-6 95CD N2 N2-5 Eo C C 95CD MECH ROOM w 0 A2,N3,N4 401 � N2 Q Al u% Q AERATION P4 N2_ TAN KS 3ocD °' 0 Ld P3 w W w Q W Nz L97M07 U Az,N3,N4 P2 A,(g),2% F 2A, L9 2 L97M03 Al F N2-1 N2-2 A, L97M05F M CLEAN IN PLACE (CI P) L97S01 \ 75CD J N2 \ 75CD BLDG AREA 403 IS06 A, 2 N2 � A2 A2,N3,N4 ELECT ROOM � 2A, G MBB J A 400 2N2 A3(g) FACP N2,N37N4 T Pz w G BPS JM N2-3 N,(g) L97M04 75CD 0 A3(g),N,(g) WP N U � LLN LL -Ln TO CHEM BUILDING Q m Q LLJ J w �a W w 0 W z u— - MBR BU LD NG PLAN SCALE: 1 /8"=1'-0" NORTH JOB # 1311C FA -03 3OF9 M CD rl- MOVE EXISTING BLOWER BLDG ZONE 4 TO NEW INPUT MODULE U � J N cn d CV ADDED CONTROL BUILDING LAYOUT w b J FACP INSTALL CONTROL REALY TO ACTIVATE ZONE 4 NEW MBR BUILDING FIRE ALARM PANEL ALARM o w � DESIGNER OE RECORD:00 Q�� ZONE 1: MAN BUI D NG OFFICES 4 ;'� SANDIFER DEER wM ZONE 2: MAN BUILD NG STORAGE ROOMS M± ± ZONE 3: MAI NTENACE B OSOEIDS CHEM /SLUDGE BUILDINGS NICET I (FAS) a 1 ZONE 4: MBR FACP INTERFACE INPUT #129796 NAC 1: MAN BUILDING NAC 2: MAINTENANCE BUILDING U) z w 0 U IJ cnw c _ 2 a >� Q 0 � 0w a-> a -w Qly- o� �w X o� wQ �cy �Q cl)� > z=o ��� oZcn III W F-- N I pn N I CMNINK FENCE W/R" MRE Q 0 N N I SOLIDS MAINTENANC BUILDING BUILDING wo� C NTROL BUILDING NOTE: LOCATE INTERFACE CONTROL RELAY AND INPUT MODULE >o <. •a 10 NEXT TO FACP . ' J.O. 4 ' '• F. 30' ENE. B B FACP C M W L97M16 A2 L97M15 >- ~— V J SLUDGE STORAGE D TANKS W INTERMEDIATE >. PUMP STATION FE] 000 CENTRIFUGE ° o U � m m PUMP _00 ii STATION C.I.P. \ 0 FROM CENTRIFUGE 0 BLDG BLOWER Q cl::� o STATION A2(g) BUILDING El cn LL U Jr. EXISTING CONTROL BUILDING(a) SCALE: NTS MBR NORTH BLDG -� 0 w 0 cn FORWARD FEED BLDG 11C r -- U LL- Ln o N U 00 Q 0-) C EMICAL= Q a_ Q z 3:= BLDG = Q w LTJ o � z LL - JOB # 1311C FA -05 5OF9 N ME PRO W P4 CHEMICAL CHEMICAL BLDG. BLDG. EXIT DESIGNER Q A M F) I F-1:7F� OF RECORD: F) F- F- F� MBR ELECTRICAL ROOM S_:; &. NAC RISER!,?�, SCALE: NTS L cn I -- :Z, Li 0 w Cf)(n Cf)w _Q p J � Q � O w a-> 0_ W Q ly- X_ O � w p � w Q p cy (� Q Cl) d Z = p p z cn M M LLj N N ~r) 00 Q N N 0 I I cD JOB # 1311 C FA -06 W (n ry ry N LL N U � 00 Q 0-) a_ Q � W LTJ o � z L.L. JOB # 1311 C FA -06 M r� 00 r rn � DESGNER OE R ECORDo CONNECT TO EARTH GROUND PER ARTICLE 760 OF NEC. FAILURE TO U � 00 JAN (n � N SAND EER DEER CONNECT TO A METALLIC GROUND WATER PIPE OR GROUND ROD WILL RESULT IN LOSS OF LIGHTNING PROTECTION. PANEL NEUTRAL OR W I _J j< CONDUIT GROUND IN NOT ACCEPTABLE. USE #14 AWG MINIMUM. N j MCET IV (FAS)LLJ 2 CONNECT TO 12 A/H TO 18 A/H BATTERIES, MAX. USE #14 AWG WIRE MIN. �j � � � #`129796 (NON—POWER LIMITED) ■ Q N �M� N L7 w�LO W X N O m 2 O d 0_ z z 0 o❑ ° ® CD❑❑ CO ❑ ❑❑ ❑ Ej ® cn � w o ❑ 0 o ❑ ❑ ❑ C) w c_—) ❑ ❑❑ �_ LJ o C3❑ Li0 C3 ❑� ° ❑ o ALARM�S�DpC�WSORY TROUBLE &LENCED POWER 0 0 0 0 0 O ® O ❑ ❑ ❑ CD C3® ® a- Q o W X 0 El OO O cc ❑❑ oQ Ld O❑ O❑ O❑ O O _ o o 0 ®® 0®� °� ❑° ®g �� 0 0 0 ❑ g ❑�El U - Q ® o ° 3 O e fE O ® too En Q Eno ®;) o ® g® X z = mcmQ❑Qj C OO fn�nl G� M Gil D C�LQ40 GQ o 3 O ❑ FE3 o 4 ® 1)®® ❑ 0 +I �Q Z N mmmme ® 1) 13 z wo< N I O °_❑ �o��❑ ������ 0 00 ® U ❑ Q NCO cND®g❑Mm ❑ ❑ x � g Lam ® Lam ® ® ® + Q w o ❑ �f ❑ ❑ � Ll C3 El AND ® ® o ®�UI 0//' 4�" ° ® o N ' m FRI Q J ❑ C3FIH 9—P9�P ® 0' o o °� m � � ° z } o 000 000 ❑e ❑ ❑ ❑ ❑ ❑ s� ❑ + wo ® ® c.> J Z � LJJ O°® em ®wR ° ®_ Zm 0 0. 0 Q� 13 EJ EJ 0 0 0 0 ❑®® ° m Z ®® o ®m ®® e ® a cn ❑0 a® ® ® n n ms® 0011 E ❑ +m LJJ LL_ o 0 n®� 00❑ gng® ®� ®® o®0 D m p ❑+ �_ Z ❑ . . ®��� FUo E ® I m ❑ ❑®❑ n W ❑ 0® ® ��❑ �000 ® 000 ®�®0❑❑ ❑ ❑ m ao J O O ❑ ( L � ®° C7 °® ED � D m®®o Q I� 0 ® � ® J L� LLJZ 0 oaoo 0 0 q^Q MM0 004�7 0 0 1��1 Q cn Q W Cn (n (n (n (n (n n n n n n n Z Z Z Z I+ I+ I+N N N N 70 70 Lluu❑ --I _v _0 m = m = O 0 m O O c LiJ (n LL. N 0 0 LL_ ❑ Q 0-) Q 0 0 � LLJ W LTJ o � z L.L. SILENT KNIGHT 6820 CONTROL PANEL WIRING TERMINALS 6820 WIRE DIAGRAM 2 SCALE: NTS SCALE: NTS JOB # 1311C FA -06 7OF9 M CD rl- U � 00 SET STROBE CANDELA OUTPUT AS SHOWN ON PLANS. SIGNAL LINE CKT LOOP 1(-) DESIGNER OF R J N N Lo SET HORNS TO LOW UNLESS NOTED OTHERWISE. 2(+) 1(-) SPRINKLER DEVICE, OR N.O. DRY CONTACT DEVICE.E SPRINKLER DEVICE, OR N.O. DRY CONTACT DEVICE w D CV J SIGNAL LINE CKT LOOP 1 (+) O SANDIFER DEER (~ Q X U >_� BETWEEN J -BOXES �3 47K EOL (n d RESISTOR RESISTOR NICET IVO (FAS) LLJ �3 r- ro SPECIFICATIONS: MOUNTING: 6.1 INCH DIAMETER (15.5 CM) q129796 TO ELEVATOR RECALL CIRCUIT(S). Q C`1 C'J DD (!) r7 c` 4 INCH SQUARE BOX WITH OR WITHOUT PLASTER RING B300-6 BASE ] VERIFY CONNECTIONS Lq7 r- ENTIRE STROBE LENS TO BE LOCATED MIN. DEPTH 1.5 INCHES INCH OCTAGONAL BOX, MIN. DEPTH 1.5 INCHES (TYPICAL, WHEN REQUIRED) 3.5 INCH OCTAGONAL BOX, MIN. DEPTH 1.5 INCHESO WITH ELEVATOR CONTRACTOR. II no4 X Cil BETWEEN 80" AND 96" AFF AND NO SINGLE GANG BOX, MIN. DEPTH 1.5 INCHES TO WON FIRE DOOR CONTROLLERVERIFY m CLOSER THAN 6" BELOW CLG. ]'I CONNECTIONS O dMANUAL ALARM STATION, DEVICE, OR Q 0 a,SPRINKLER � zN.O. WITH CONTRACTOR. DRY CONTACT DEVICE.IA 6 34,A 7 2 7 2 (0 Il W 0) 4 t0 I- W O z ci b I 1 = v v = 0 o b 3 3 1 1121131141 9 3 SPEAKER/STROBE STROBE 80" TO BOTTOM YEL(-) 47K EOL Q M N O O D M N O O OF J -BOX RESISTOR (+)VIO O O O O MOUNTING DETAIL RED(+) (-)BLK FINISHED FLOOR (-)TO NEXT DEVICE � (+)TO NEXT DEVICE Z w 4" x 2-1/8" SK—MIM SK MONITOR -2 SK PULL—DA SK RELAY 0 0 J -BOX, TYP. 4" x 2-1/8" 1A, TYP. ADDRESSABLE MONITOR MODULE DUAL MONITOR MODULE ADDRESSABLE PULL STATION ADDRESSABLE RELAY MODULE U J -BOX, TYP. (TYPICAL, WHEN REQUIRED) ( TYPICAL, WHEN REQUIRED) (TYPICAL, WHEN REQUIRED) (TYPICAL, WHEN REQUIRED) Ld a ® I J Q � II II 0 W> a- Q W ly- ckf X O 0 0< W< C n — W Q d SPEAKER/STROBE OR STROBE MOUNTING PLATE (-)BLK 1C (-)BLK TO DOOR HOLDERS Z = � o cn FRONT VIEW SIDE VIEW (+)RED (+)RED p z cn (PROVIDED WITH ENCLOSURE) R -20E N Cr'C TO FAN PR -1 RELAY w N N _ —24VDC 1C r10 C I\ I SHUTDOWN CIRCUIT. VERIFY CONNECTIONS. UPON AC POWER LOSS THE BLUE ON F-- ro CV 00 (V FROM SNAC-81 I� I�yyNA N/Ol�yl (TYPICAL, WHEN REQUIRED) RELAY WILL DE -ENERGIZE WHICH WILL DE -ENERGIZE N.C. THE DOOR HOLDERS KEEPING WIRE NUT 0 cD +24VDC �_ y 18/35VDC N/Cl�yl LJ l�yl THE LOAD OFF OF THE BATTERIES. YELLOW TYPICAL WALL MOUNT DETAIL C N/O N1 , ORANGE � O SCALE: NTS - TEST COIL (+) 8 TEST COIL (-) 7 0 RELAY SHOWN oM (+) s to co r- 00 0 ADDRESSABLE RELAY REQUIRED FOR ,� n w m oENERGIZED (-)BLK RED(+) SLC LooeOUT 5 0 Tc N N N HVAC SHUTDOWN INTERFACE. ADD i i I I I N N N T i I I WIRE NUT g� OM (-) 4 Z z R -20E RELAY WHEN SWITCHING ' + AC VOLTAGE. VERIFY IN FIELD, TYP. Z _ ELA '' E Op NOT PAlIyt RA/RTS (-) 3 RA (+) 2 0 _' v b ' Z 9 g IF SWITCHING LOW VOLTAGE THROUGH 0 a M N o O AOM-2RF, R -20E RELAYS ARE NOT NEEDED. _' a 9 9 s a ,� N o 120VAC 24VDC FROM SNAC-4/8 �❑I-! RTS (+) 1 0 0 VERIFY WITH MECHANICAL CONTRACTOR. LLJ P❑ DNR DUCT DETECTOR HOUSING (-)TO NEXT DEVICE (REQUIRES ADDRESSABLE SMOKE DETECTOR) (+)TO NEXT DEVICE "'0' (TYPICAL, WHEN REQUIRED) SK— RELAY IDP RELAY IF RELAYS ARE NOT WIRED IN A ADDRESSABLE RELAY MODULE 1A, TYP. IF RELAYS ARE NOT WIRED IN ADDRESSABLE RELAY MODULE 77 N.E. OR FAIL-SAFE CONFIGURATION, (TYPICAL, WHEN REQUIRED) N.E. OR FAIL-SAFE CONFIGURATION, (TYPICAL, WHEN REQUIRED) W O THEY MUST BE LOCATED WITHIN 3 FT. THEY MUST BE LOCATED WITHIN 3 FT. OF THE CONTROLLED DEVICE. OF THE CONTROLLED DEVICE. LL Q Cf) (PROVIDED WITH ENCLOSURE) CD J Q W 0 R -20E _ ^II �_ W USE UNSHIELDED WIRE UNLESS OTHERWISE NOTED. SK—MONITOR2 47K EOL & Ngo 120VNA RESISTOR (s) C 0 \ ALL SHIELDS MUST BE TIED THROUGH, ISOLATED, AND TERMINATED, IF USED. O O O O NC 1D—/ O LjJ z FCI SLC LOOPS ARE LIMITED TO 1,000' MAX., PER LOOP, IF SHIELDED WIRE IS USED. NCO J 45 Q � e QQ T-, (TYPICAL, WHEN REQUIRED) (n LL 3 g (RELAY SHOWN ENERGIZED) S-32 _ 2 CKT, 7 � C+1 1 0 -T -z 8 ELEVATOR SHUNT POWER SUPERVISION CD 0 CKT-2 9 /TAMPER SUPERVISION DEVICE ADDRESS � 99 DETECTORS. MAX./SLC 98 MODULES MAX./SLC (PROVIDED WITH ENCLOSURE) c R -20E 47K EOL & N/C 120VAC RESISTOR TYPICAL CEILING MOUNT DETAIL Z DEVICE TYPE DESIGNATION. N/0 NA SCALE: NTS - S = SMOKE DETECTOR M =MODULE J & 0 o & N/0 LLJ 1D O N/O S (/) TYPICAL ADDRESS DESCRIPTION (TYPICAL, WHEN REQUIRED) (RELAY SHOWN DE -ENERGIZED) , ^ VNI �1 B, TYP. �1 C, TYP. W LL_ Ln + + + + + ` 4.7K OHM (a) �` 0` X + 24VDC 1 ST FLOOR ELEVATOR SHUNT ACTIVATION 00 Q 0— i 1 /2 WATT - DOOR HOLDER POWER c z < -� ` OUT -1 OUT -3 J J � SNAC 4 Q W � W o � z TO ELEV. SHUNT NEUTRAL �1 B, TYP. 120VAC POWER BRKR., POWER AVAILABLE LIGHT + + + + + BY SITE ELECT. SWITCHED HOT CONTR. HOT X `o `o `0 4.7K OHM - (a) DETAILS SHOWN ARE TYPICAL AND ALL SWITCHED HOT TO ELEV. SHUNT 1/2 WATT DETAILS MAY NOT APPLY TO ALL JOBS. TRIP BRKR., BY SITE ELECT. CONTR. OUT -2 OUT -4 REF. LAYOUT DRAWINGS& B.O.M. 135' FIXED TEMP. HEAT DETECTOR SNAC 4 W/ N.O. CONTACT TYPICAL NAC WIRING DETAIL TYPICAL ADDRESSABLE DEVICE WIRING 4 HOT SCALE: NTS _ (j) SCALE: NTS _ JOB # 1311C ELEVATOR SHUNT TRIP DETECTOR FA -08 8OF9 M CD rl- U � 00 DESIGNER OE RECORD: N JAr-i Cl) 0 Lo ENTIRE STROBE LENS TO BE LOCATED N w J SAND�FER DEER BETWEEN 80" AND 96" AFF AND NOX CLOSER THAN 6" BELOW CLG. >_ >- u- to CCT I V(FAS)4" CEILING N Q P0, ❑Q X 2.1/8" J—BOX, TYP. N #129796 .� �► �M°° N O SNACII EXIT DOORWAY w C4 O N FACP W W OPENING m O d ANNUN II zo^ o I� a 80" BATT 72" a 60" 48" _ _ 0 5' MAX. I~ HORN/STROBE OR STROBEMANUAL MOUNTING PLATE 80" TO BOTTOM STATION OF J—BOX FIRE 0 U) 11111111111111111711111111z w FINISHED FLOOR :>b EQUIPMENT MOUNTING DETAIL TYPICAL HORN 8c STROBE WALL MOUNT DETAIL 0 SCALE: NTS _ SCALE: NTS _ (a 42" MIN. 48" MAX. Ld cn c w NOTES: — a 1. DETAIL NOT INTENDED TO SHOW SPATIAL RELATIONSHIP OF DEVICES. a 0 REFERENCE FLOOR PLANS FOR ACTUAL LOCATIONS. o 0 tZ w > FINISHED FLOOR 0-w Q ly- 0 x 0' o w � Q INSTALLATION NOTES: � cy 1. THE OPERABLE PART OF EACH MANUAL EIRE ALARM BOX "—' SHALL BE NOT LESS THEN 42" AND NOT GREATER THAN 48" A.F.F. z = o 2. MANUAL FIRE ALARM BOXES SHALL BE LOCATED WITHIN o Z N 5' OF THE EXIT DOORWAY OPENING ON EACH FLOOR. w N (V F-- Q 0 I N I I CO I CEILING MANUAL STATION MOUNTING DETAILS 3 `� TOP OF DEVICE SPEAKER/STROBE SCALE: NTS _ o o HORN/STROBE 6" MIN. DETAILS SHOWN ARE TYPICAL AND ALL STROBE DETAILS MAY NOT APPLY TO ALL JOBS. o o REF. LAYOUT DRAWINGS& B.O.M. SPEAKER HORN VISUAL DEVICE STROBE LLJ HORN/STROBE AUDIBLE DEVICE SPEAKER/STROBE HORN OR SPEAKER 96" MAX. TOP OF LENS 90" MIN. 80" MIN. W TOP OF DEVICE BOTT. OF LENS J u CD LLJ I U � U 3 CO Z DETECTORS WITHIN THIS AREA SHALL HOT BE LOCATED DIRECTLY IN THE AIR STREAM SDIFFUSERR OF SUPPLY AIR REGISTERS. 36' a' TUBE SUPPORT HOLE REQUIRED FOR BEND OR OTHER DUCTS MORE THAN 3 FT. WIDE. OBSTRUCTION \ LLJJ F__ z TO PREVENT THE CLEAN AIR am- FROM BLOCKING THE SMOKE MOUNT SMOKE DETECTOR A TO THE DETECTOR WHEN THE MINIMUM OF 3' AWAY FROM BATH/ BACK BOX U (n - L O :2L FINISHED FLOOR SA & RA ARE WITHIN 15 FT. SHOWER/KITCHEN ROOM OPENINGS. NO' MOUNT DETECTOR 1.5 FT FROM CEILING LEVEL BETWEEN BACK BOX CEILING THE SA AND RA REGISTERS. 000 SMOKE DET. DUCT WIDTH AIRFLOW SUPPLY AIR D IFFUSER -NEE��ir- r7, OR HEAT Dom, iDIRECTION INSTALLATION NOTES: 3 - O SMOKE DETECTOR MIN. DISTANCE - INSERT RUBBER PLUG IN THIS END OF INLET TUBE 1. MOUNT VISUAL AND COMBINATION AUDIBLE/VISUAL HORN BASE MODELS: + + + 4•SO. BOX 6-10 DUCT 6-10 DUCT APPLIANCES SUCH THAT THE ENTIRE LENS IS NOT LESS THAN HACK BOX LIGHT FlXTURE j' - Q" NON -HORN BASE MODELS 4. SO. BOX RETURN TUBE SLANT CUT FACE ORIENTED DOWNSTREAM OF AIRFLOW EQUIVALENT WIDTHS EQUIVALENT WIDTHS �(DO 80" AND NOT GREATER THAN 96" A.F.F. 00 + + + MIN. DISTANCE 3' OR 4" OCTAGONAL 00 SHED/SLOPE CEILING (>1:8 PITCH) NOT INSERT RUBBER PLUG IN OUTLET TUBE) 2. MOUNT AUDIBLE APPLIANCES SUCH THAT THE TOP OF 0 MIN. DISTANCE 0 THE APPLIANCE IS AT A MINIMUM HEIGHT OF 90" A.F.F AND t 3L) BACK BOX RETURN AIR SYSTEMS: INLET TUBE HOLES FACE UPSTREAM OF AIRFLOW SMOKE DETECTORS SHALL BE INSTALLED IN RETURN AIR SYSTEMS WITH A DESIGN CAPACITY GREATER THAN 2000 CFM 0.09 M/S) IN / ) BELOW THE FINISHED CEILING AT A MINIMUM HEIGHT 6". APPUAN ESNOTIFICATION 4` THE RETURN AIR DUCT OR PLENUM UPSTREAM OF ANY FILTERS, EXHAUST AIR CONNECTIONS, OUTDOOR AIR CONNECTIONS OR INDOOR 4' SQ. Box BACK BOX DECONTAMINATION EQUIPMENT AND APPLIANCES. 3. IN AREAS WHERE MORE THEN TWO VISIBLE NOTIFICATION IN LL_I C/) APPLIANCES ARE IN ANY FIELD OF VIEW, THEY SHALL FLASH AUDIBLE OR VISIBLE ONLY AUDIBLE/VISIBLE DEVICES DEVICES WALL COMMON SUPPLY AND RETURN AIR SYSTEMS: MULTIPLE AIR HANDLING SYSTEMS SHARE COMMON SUPPLY OR RETURN AIR DUCTS OR PLENUMS WITH A COMBINED DESIGN c IN SYNCHRONIZATION. SHALL BE MOUNTED SUCHN0. SHALL BE MOUNTED SUCH THAT THE MOUNTING HEIGHT THAT THE MOUNTING HEIGHT MEASURED TO THE BOTTOM SMOKE DIET.WHERE OR HEAT DET. 4• CAPACITY GREATER THAN 2000 CFM (0.9m3/s), THE RETURN AIR SYSTEM SHALL BE PROVIDED WITH SMOKE DETECTORS. C:) 4. IN CORRIDOR APPLICATIONS: MEASURED TO THE BOTTOM OF THE STROBE LENS OF THE NAC APPLIANCE SHALL BE 80" ABOVE THE O RETURN AIR RISERS: , ^ N A. VISIBLE NOTIFICATION APPLIANCES SHALL BE LOCATED PULL STATION SHALL BE 80" ABOVE THE FINISHED FLOOR. FINISHED FLOOR. O 12" WHERE RETURN AIR RISERS SERVE TWO OR MORE STORES AND SERVE ANY PORTION OF A RETURN AIR SYSTEM HAVING A DESIGN CAPACITY GREATER THAN 15000 CFM (7.1 SMOKE DETECTORS SHALL BE INSTALLED AT EACH STOREY. SUCH SMOKE DETECTORS >- U O7 WITHIN 15' FROM THE END OF A CORRIDOR WITH SEPARATION TU 0 SMOKE DET. (ONLY) if m3/s), LL LL Ln NOT GREATER THAN 100' BETWEEN APPLIANCES, B. WALL—MOUNTED VISIBLE NOTIFICATION APPLIANCES SHALL a8• BOX FLAT CEILING SHALL BE LOCATED UPSTREAM OF THE CONNECTION BETWEEN THE RETURN AIR RISER AND ANY AIR DUCTS OR PLENUMS SUPPLY AIR SMOKE DETECTORS: Q BE PERMITTED IN EITHER THE END WALL OR THE SIDE WALL I IF INSTALLED, SUPPLY AIR SMOKE DETECTORS SHALL BE MOUNTED IN THE DUCT DOWNSTREAM OF BOTH THE FAN AND THE FILTERS. Q OF THE CORRIDOR. NDT ADDITIONAL SMOKE DETECTORS IN THE SUPPLY AIR SYSTEM ARE NOT REQUIRED WHERE THE AIR PASSES THROUGH OTHER SMOKE C. IF THERE IS AN INTERRUPTION OF THE CONCENTRATED COMPARTMENTS. VIEWING PATH, SUCH AS A FIRE DOOR, AN ELEVATION CHANGE, SMOKE DAMPERS THAT ARE PART OF A SMOKE BARRIER SHALL BE INSTALLED IN THE PLANE OF THE FIRE PARTITION AND NOT AFTER J J CIE W OR ANY OTHER OBSTRUCTION, THE AREA SHALL BE TREATED SMOKE & HEAT DETECTOR PLACEMENT THE FIRST AIR DUCT INLET OR OUTLET, WHICHEVER IS CLOSER TO THE SMOKE BARRIER. IF THE SMOKE DAMPER IS CONTROLLED BY Q = AS A SEPARATE CORRIDOR. GENERAL NOTES: AIR SYSTEM SMOKE DETECTOR IT SHALL BE LOCATED UPSTREAM OF THE SMOKE DAMPER BUT AFTER ANY INLET OR OUTLET IN W A. DO NOT APPLY POWER TO ANY DEVICE UNTIL AUTHORIZED BY A HONEYWELL REPRESENTATIVE. THAT DUCT. 5. SLEEPING AREAS: B. SEE FLOOR PLANS FOR ALL DEVICE LOCATIONS, DEVICE COUNTS, AND DEVICE ADDRESSES. W O A. FOR ROOMS WITH A LINEAR DIMENSION GREATER THAN 16', C. FOLLOW DEVICE INSTALLATION INSTRUCTIONS INCLUDED WITH DEVICES. WHERE IN -DUCT SMOKE DETECTORS ARE INSTALLED IN CONCEALED LOCATIONS MORE THAN 10ft ABOVE THE FINISHED FLOOR, OR IN ARRANGEMENTS WHERE THE DETECTOR'S ALARM LIGHT IS NOT READILY VISIBLE TO RESPONDING PERSONNEL, THE DETECTOR SHALL z THE VISIBLE NOTIFICATION APPLIANCES SHALL BE LOCATED D. DETECTOR GUIDELINES: NO SMOKE DETECTORS ALLOWED IN GARAGES. BE PROVIDED WITH REMORE ALARM INDICATORS TO BE INSTALLED IN A READILY ACCESSIBLE LOCATION AND SHALL BE CLEARLY WITHIN 16' OF THE PILLOW. NO SMOKE DETECTORS ALLOWED IN UNFINISHED ATTICS. LABELED TO INDICATE BOTH THEIR FUNCTION AND THE AIR HANDLING UNIT(S) ASSOCIATED WITH EACH DETECTOR. (EXCEPTION: B. IF THE DISTANCE FORM THE TOP OF THE STROBE LENS IS NO SMOKE DETECTORS ALLOWED IN AREAS WITH >100'F OR <40'F. WHERE THE SPECIFIC DETECTOR IN ALARM IS INDICATED AT THE CONTROL UNIT) EQUAL TO OR GREATER THEN 24" FROM THE CEILING THEN ION SMOKE DETECTORS MUST BE > 20' FROM COOKING APPLIANCES. DETECTORSO SMOKE ALLOWED R COOKING (PHOTHE STROBE SHALL BE 110cd. IF THE DISTANCE FROM THE O EDETECTORS WIT IN3'FROMDOOR TOKI KITCHEN ORS OWER/TUOM NO SMT B ROOM TOP OF THE STROBE LENS IS LESS THEN 24" TO THE CEILING NO SMOKE DETECTORS WITHIN 3' HORIZONTAL FROM CEILING FAN BLADE TIP. THE STROBE SHALL BE 177cd. SMOKE DETECTORS ARE REQUIRED IN BASEMENTS ON CEILING ADJACENT TO STAIRWELLS. MOUNTING HEIGHTS FOR WALL MOUNTED NOTIF APPLIANCES 4 ADDITIONAL DEVICE MOUNTING DETAILS 5 DUCT DETECTOR MOUNTING DETAILS 6 SCALE: NTS SCALE: NTS SCALE: NTS JOB # 1311C FA -09 80F9 M 00 I- U � 00 J CV P7 :2 � CV W J ~ J X FROM MBR O d O BUILDING M DEQ G ER OE RECORDo � Q r �N00 A3(g),N1(g) L97M02 (n M N A3 P, SANDFER DEER woN m L97M01 MCET V FAS a A3(g) N,(9) N, 129796 N1-2 15CD . WP;o; 0N,-1 Ao 75CD 2N, cn z w O U w Cn Cn w LJ J Q Q 0 � � 0oo� a-> _w 0_ Q W ly- ckf O X_ � w o w cn � Q cy Q CHEMICAL BUILDING FLOOR PLAN o z N SCALE: 1/8"=l' -O" NORTH W N N Q 0 I N I co I STORAGE co AREA >> ELECT w o DIV 2 NEW HEAT DETECTOR IN NEWLY AREA ADD NEW THERMAL PROBE IN HAZARDOUS PARTITIONED ELECTRICAL ROOM (n U STORAGE AREA ROOM Z3-DO3 m EXISTING Z3-DO7 H,T 26 Z3-DO5 EXISTING Z3 -D04 2B EXISTING Z3 -DO ( � F W B B B O BACKBOX AND u- >- 00 RIDGID CONDUIT EXISTINGV) m TO MEET CLASS 1 Z3 -D06 F DIV 2 W REQUIREMENTS > >U W LL LL- Q u/ j i W LLJz U 00 Q U_ w LiJ EXISTING FROM J � ,L W MAINT BLDG TO CONTROL ZONE 3 HEAT BUILDING A2(g) DETECTOR B(g) L97M13 `,M EOL" o X ° 2Az(9),N4(g) P6 2A2 L3 L97M14 F o X FROM c W 4-2 15CD �o Au,N4 a_ FORWARD FEED ,o. N4-1 BUILDING A2(g),N4(g) N LL N U Li 75CD WP si Ln Q 0'-) EXISTING BIOSOL DS BULDNIG PLANS 3 z SCALE: 1/8"=l' -O' _ C Q CIE NORTH W � � Q LL --j W o � � z I.L. CENTRIFUGE PUMP STATION FLOOR PLAN 2 SCALE: 1/8"=1'-0" NORTH JOB # 1311C FA -04 4OF9