Loading...
Plan 2386 GL Page A2 5-3-202235'-0" of do op ---------- i - TYP I I OPT. COVERED PATIO 8'-0» 11'-� 8'-0» I 8'-0» HIGH EFFICIENT HVAC 3.5: Of AIR SOURCED HEAT PUMPdl .10 MIN. HSPF OF 11.0 I I 2'-7" ENERGY CREDIT = 1.5 oe STEP HEAT I I PUMP I STOOP SW -4 6-OOx5 0 XO SW -4 I STEP SW -4 _ 4-OOx5 0 XO _ SW -4 HB 6-0x6-10 SGD (SG) `o Oj i 0o N I C? ii Q:> 8$ -6$p , -6» u w u GREAT ROOM DINING 8' CEILING, TYP. KITCHEN 2x4 WALL BELOW o R 34-1/2 HIGH AD1 OPTIONAL o oM ALL WALLS DIRECT VENT OF CANTILEVER GAS FIREPLACE. INSTALL z0 PER CODE & MFR. SPECS. <[If >o 17,000 +/- BTU 13'-2" 4'-0" 2'-4" r 0 i Tn SHELVES 0 0 R&S TP I� o 2-4 N 2-4 PWDR I OPT. 5-0 I I \ 11 ov I I � DEN N I I � 5-0x4 0 XO SW -4 4� SW -4 1'-9" 16'-0" MAIN LEVEL: 1'-9" 2'-3" 1423 S.F. 2'-3" 2386 S.F. 5'-6" op 423 S.F. FRONT PORCH: 5'-6" REAR STOOP: AD1 19'-6" el N I42" L/24 HALF-WAL 11'-0" OPT. OPEN RA L C14 N " HANDRAIL 003 c0 rn I 2 (STORAGE 7. 5" ISE 10 RUN 1 1 0v ' CLOSET CR CEEK I I 1 16 RISES_F _ IAD1 I HEAT SW -47 Elf rn PUMP WH STEPS AS REQ'D N I I 10" RUN MIN. 7.75" RISE MAX M 3' SQ. CONC. Z 2-8STOOP - mn W/ OPT. I OP AD1 HEAT ALARM H❑110v INTERCONNECT OPT. 2-3 1-3/8" MIN. SOLID -CORE ;. TIGHT FITTING DOOR W/ I I 20 MINUTE MIN. RATING 1RZ- W/ S.C. HINGES I 4" STEEL PIPE BOLLARD I EFFICIENT WATER HEATING 5.5: AD1 _Y o i Ncr_ O ELEC. HEAT PUMP W.H N I NEEA TIER III SPECIFIED ENERGY CREDIT — 2.0 r?co I GARAGE I I 5/8" TYPE "X" G.W.B. ON ALL WALLS I o AND CEILING, WRAP wZ o I EXPOSED POSTS & BEAMS I - o BEDROOM 2 cr-W }C -D X C�l N o ' Ln H - 00 I 16-0x7-0 OHD oX O CV SW -3 FSW731 I PORCH 0 i Tn SHELVES 0 0 R&S TP I� o 2-4 N 2-4 PWDR I OPT. 5-0 I I \ 11 ov I I � DEN N I I � 5-0x4 0 XO SW -4 4� SW -4 1'-9" 16'-0" MAIN LEVEL: 1'-9" 2'-3" 1423 S.F. 2'-3" 2386 S.F. 5'-6" op 423 S.F. FRONT PORCH: 5'-6" REAR STOOP: 16 S.F. 19'-6" el ol 4'-6" 11'-0" MAIN LEVEL FLOOR 35'-0" PLAN ALLTES FANSMIUST VENTMTOXTHESOUTS DE LINO SAFTEY GLASS NOTE: (SG) DENOTES SAFETY TEMPERED GLASS O110v DENOTES SMOKE DETECTOR LOCATION ALL SMOKE DETECTORS TO BE 11 OV. INTERCONNECTED WITH BATTERY BACK-UP BUNDLED STUD NOTE: SEE FLOOR FRAMING FOR BUNDLED STUD / POST LOCATIONS CO CARBON MONOXIDE DETECTOR TO BE 110v WITH BATTERY BACK-UP TYPICAL DETAILS NOTE: REFERENCE DETAIL XX PAGE S2 FOR TYPICAL CORNER FRAMING SHEAR WALL NOTE: sw-x REFERENCE DETAIL ZZ PAGE S2 FOR TYPICAL OPENING FRAMING I ENERGY & BUILDING LEAKAGE 1 TESTING NOTES: REPRESENTS SHEAR -WALL LOCATION AND TYPE. SEE PAGE N1 FOR COMPLETE INFORMATION REFERENCE PAGE S1 FOR SHEAR -WALL SCHEDULE FRAMING & ROUGH OPENING NOTES: -EXTERIOR HINGED DOORS (VERIFY W/ CONTRACTOR) FURR BOTTOM WITH 3-1/2" x WIDTH x 7/16" OSB SINGLE DOOR : WIDTH + 2" x 83" DOUBLE DOOR SET : WIDTH + 3" x 83" -INTERIOR HINGED DOORS SINGLE DOOR : WIDTH + 2" x 82-1/2" DBL. DOOR SET: WIDTH + 2" x 82-1/2" -BYPASS DOORS: WIDTH - 1" x 83" -SLIDING GLASS DOOR: WIDTH + 0" x 82-1/2" PLACE NERVASTROL PLASTIC UNDER DOOR WITH CAULKING UNDER AND OVER NERVASTROL. -ALL 8-0 DOORS (FRONT DOOR & FRENCH): WIDTH + 2" x 99" PROVIDE 2x BLOCKING AT THE FOLLOWING LOCATIONS: HANDRAIL BACKING ® 32" CENTERLINE TOWEL BAR BACKING 0 48" CENTERLINE TOWEL RING BACKING 0 60" TOILET PAPER BACKING ® 25" ALTERNATE KITCHEN - oa,-,_o XO -o- OPT. GUEST SUITE FLOOR AREA: I =� MAIN LEVEL: 963 S.F. UPPER LEVEL: 1423 S.F. TOTAL: 2386 S.F. GARAGE: 423 S.F. FRONT PORCH: 96 S.F. REAR STOOP: 16 S.F. OPT. COVERED PATIO: 100 S.F. PLUMBING NOTE: CLOTHES WASHER AND DISH WASHER MUST BE INSTALLED WITH WATER -HAMMER PREVENTION DEVICES. Lo 0 N 16'-6" 21- 6» 121-011 SW-4 3-0x5 0 SH I EMERGENCY EGRESS PER NOTE #40 PAGE N2 I I I PRIMARY BEDROOM I �I 0 N I 01 10v N C"i 3 � 4-6 do 00 O CO 42" HALF -WALL 1 1 ov 13'_6» O I =� 0 SH SW -4 ---R&S ----� HIGH EFFICIENT HVAC 3.5: AIR SOURCED HEAT PUMP MIN. HSPF OF 11.0 ENERGY CREDIT - 1.5 HIGH EFFICIENCY HVAC DISTRIBUTION 4.2: DUCTS WITHIN CONDITIONED SPACE ENERGY CREDIT - 1.0 /AA_� A7 4'-7" 5'-0" oe 2'-6» 2'-6» 4-0x4-0 XO (SG)_ -x-1 3 WE 5-0 TUB TE J O a N i 35'-0" -0x 0 SH SW -4 ---R&S ----� 4'-7» 5'-0» O 8'-11» 2-0 11 Ix5 SH o -0x 0 SH SW -4 ---R&S ----� O - C14 N TB WALK-IN I o CLOSET _ Elf 2-4 PRIMARY BATH II I I mn OPT. ;. ;t; TR 1RZ- i Ncr_ O I W I AIR HANDLER o wZ o sEE N1.1 BEDROOM 2 cr-W }C -D X C�l N 00 CD oX O CV N �= LINEN I Of N U Y 3 -2 1 -9 7 -3 ww __ WZ o o�l WH _ o ,J ' SE PAS N1 � o 110 00 — Nto N 5-0 BP 2-4 --- -- CD �? O N STUDY LOFT co 2.4 �OZ 1 1 ovJ R&S N '�' I 8' CEILING, TYP. — — — — — — — CV TR 5-0 BP CNo �11Ov W/ BEDROOM - 13,_ 6„ ,,, �; 5,_ 0» I BONUS TPS BATH OPT. BEDROOM 4 O NI I 5-0 TUB / SHOWER COMBO EMERGENCY EGRESS PER SW -4 I NOTE #40 PAGE N2 6-0x4 0 XO „ SW -4 O5 SW -4 9 1 00, 00, 141-019 5'- 6" oll 35'-0" 1� UPPER LEVEL FLOOR PLAN FRAMING & ROUGH OPENING NOTES: -EXTERIOR HINGED DOORS (VERIFY W/ CONTRACTOR) SINGLE DOOR : WIDTH + 2" x 83-1/2" DOUBLE DOOR SET : WIDTH + 3" x 83-1/2" -INTERIOR HINGED DOORS SINGLE DOOR : WIDTH + 2" x 82-1/2" DBL. DOOR SET: WIDTH + 2" x 82-1/2" -BYPASS DOORS: WIDTH - 1" x 82" PROVIDE 2x BLOCKING AT THE FOLLOWING LOCATIONS: TOWEL BAR BACKING ® 48" CENTERLINE TOWEL RING BACKING ® 60" TOILET PAPER BACKING ® 25" I O110v BEDROOM 3 16'-6" mn - co I I EMERGENCY EGRESS PER NOTE #40 PAGE N2 — I 6-0x4-01 XO I FIRE BLOCKING NOTE PROVIDE FIRE BLOCKING AT THE FOLLOWING LOCATIONS: - AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES. - IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS INCLUDING FURRED SPACES AT THE CEILING AND FLOOR LEVELS AND AT 10 FT. INTERVALS BOTH VERTICAL AND HORIZONTAL - IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND IN LINE WITH THE RUN OF STAIRS IF THE WALLS UNDER THE STAIRS ARE UNFINISHED -IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS THAT AFFORD PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS, WITH NONCOMBUSTIBLE MATERIALS. - AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR FACTORY BUILT CHIMNEYS. 15'- 6" GAS BURNING APPLIANCE NOTE GAS BURNING APPLIANCES SHALL BE ANCHORED TO RESIST SEISMIC HORIZONTAL DISPLACEMENT PER IRC M1307.2 , THE ELEVATION OF THE IGNITION SOURCE TO BE 18" MIN. ABOVE THE FLOOR LEVEL PER IRC M1307.3 11M TA� �o 24149 � Sj �NA � 1 EXPIRES 2/1/2023 dan@brobstdesignworks.com 206.409.6690 U) H u— 0 w � z �wC-0 Q M Q�N � u� o C) O p- c) J 00 z LL N 0 C ti 0o O 00 �--� o �un 3: � Z N J O N W IME Z H W u c/) Q U U) Q 0o 0 qqr- c� REVISED 5.3.2022 1/4))=l) -O)) SCALE 11.16.2021 DATE 2386 COMPUTER FILE NAME SHEET NUMBER