Loading...
VS 8 ENGINEERING2018 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 230311 FOR: RUSH RESIDENTIAL PLAN: VISTA YELM DUPLEX SITE CRITERIA Iu I DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD (V) 561x30' U.N.O. CATEGORY DETAIL CALL -OUT g v OWNER PER OWNER OWNER (3(o)-5DS)/4'x 2�' TO 6x(o MIN. RESPONSE S1 RESPONSE SS I 25 PSF 97 MPH B D D II <15% NONE NONE 12" 0.4659 1.2869 350 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES 58 5/8x24 ANCHOR BOLT REQUIRED AT ALL HDU5 HOLDOWN LOCATIONS. TYP 14 3/4" T4G UNBLOCKED PLYWOOD OR OSB GLUED D2 4�,_O, AND NAILED W/Sd im 6"AT DIAPHRAGM BOUNDARIES AND SUPPORTED PANEL EDGES 23-112' (5DPW5 TABLE 42C) 5THD14RJ STHD 14RJ STHDI4RJ IF NEEDED - U5E DETAIL 2l /D2 FOR STEM WALLS OVER 48' UNLESS NOTED OTHERWISE 26 27 D2 D2 STEP FOLLOWING 21 ENSURE VENTS ARE NOT AT HOLDOWN OR POINT LOAD LOCATIONS (TYP) DIMENSIONS PROVIDED BY RUSH RESIDENTIAL - CONFIRM DIMENSIONS WITH RU514 PRIOR TO PLACING FOUNDATION 36 STHp 14RJ +e STHp 14RJ STHD 14RJ — — — — — — — — — — — — — — — — — — — — — — ;/,I 5THp14RJ ry+'o HDU+6---------"l — — — — 321 ----------------------- ------- I HDU 2RAWL&EACE I D3 1 I I C1;R,4WL&F,4CE I I BLOCKING RESTRAINT AT I I I JOIST END 4 EACH i I I INTERMEDIATE SUPPORT I (SEISMIC ZONE D R502.1) 1 14 HDU5 24 24 24 I I 5'-1' S' -I' 5'-1' 1'-40 , 1 24 24 24 HAUS 4x10 DF#2 +—+ I +_+ (M2) 24 31-1011 01 `r 24 .y+° 24 4x10 E)F 2 `ry' (M4) i' 30 a 5'-8" 21 _�2 2.. 1 cYl aryry I I 4x10 DF#2Tr D5L I JOIST 1 1' -IO" CM3) �� x I —-------�6--�' ----°�-----J I 4x10 D1=112 1I 5THDI4RJ (M2) I I 0 STHD 14RJ 9 I I I I D1 I I I I I I 42 1 i I 3 \ I CONCRETE PATIO AGGREGATE BASE AND REBAR BY OTHERS 4. — /� � I I I — J STHD 14 6'-0' 4" CONCRETE SLAB SLOPE GARAGE SLAB TO A DRAIN OR I VEHICLE ENTRY DOORWAY. CONTINUOUS FOOTING W/ (2) #4 REBAR AT DOOR OPENINGS. +� (15C 406.2.4 -GARAGE FLOOR 5URFACE5) I I 1 7 D1 l��ry+" ------------1 I I —----------- --- ------ 5 STHD 14 16 STHD 14 5 D1DZ STHp 14 D1 14'-3' 23'- 1'-102' W/ S' STEM AT PORTAL FRAME �AIN FL OOFR FF�A�-I f G DO NOT 6C,4LE(1/4" =1') iiia - .. © ' LN�I C---------- :: ----- . I� ��■�� i�� � I /%; mq1 STHD 14RJ STHD 14R,. I I L I I 7 D1 12 i I 1 — — — — — — — ----- D1 5 STHD 14 STHD 14 5 STHp 14 W/ S" 5TE1 W/ S" STEM AT PORTAL F 2 PORTAL FRAME $ _3, 2'-42" 4 24 4x10 DI=#2_ (M2) �6 --------- „+bi STHD 14RJ b r r ;r T 23 n7 . CONCRETE PATIO I AGGREGATE BASE AND REBAR BY r ;ry+ OTHERS r-24- - e Al LL:;f I I I STHD 14 N 0i 45'-0' 1'-10" W/ S" STEM AT PORTAL FRAME / FOUNEDATION FLAN ENGINEEDING HOLDOWN SCHEDULE Iu I FASTENERS POSITIVE POST TO FOOTING CONNECTION MODEL NUMBER RX 1 -110' NAILS SCREWS CAPACITY" I I I HDU5 - HF MEMBER 4340" 4 (14)-SDSYa'x 2�' TO (2) STUDS J5 5/9x24 URO. I 20 1 1 MIN HDU5 - HF MEMBER 5820" D2 I (20)-5DSYa x 211' TO (2) STUDS 5ST525 OR 55 7/8'x24 U- -gv HOLDOWN/STRAP MIN. UNO. HDUII - HF MEMBER 8030" N/A (30)-5D5 Ya x2Y, TO 6x6 MIN. 561x30' U.N.O. HDUII - DF MEMBER 9335" DETAIL CALL -OUT g v 6 HDU14 - HF MEMBER 9260" I (3(o)-5DS)/4'x 2�' TO 6x(o MIN. N0� HDU14 - DF MEMBER 14445" I POST PER PLAN N 5THD14/5THDI4R) - 3500" (2) STUDS W/ (30) Ibd N/A I M5TC4853 - 3900" PER MFR N/A I 1 ry+e N/A N/A I I I N/A N/A I I 1-110' 2_ 2• I01 I�4 -72"x-I2'x16" W101) 04 EACH WAY 24 IT I I I o POSITIVE POST I I 36 STHp 14RJ +e STHp 14RJ STHD 14RJ — — — — — — — — — — — — — — — — — — — — — — ;/,I 5THp14RJ ry+'o HDU+6---------"l — — — — 321 ----------------------- ------- I HDU 2RAWL&EACE I D3 1 I I C1;R,4WL&F,4CE I I BLOCKING RESTRAINT AT I I I JOIST END 4 EACH i I I INTERMEDIATE SUPPORT I (SEISMIC ZONE D R502.1) 1 14 HDU5 24 24 24 I I 5'-1' S' -I' 5'-1' 1'-40 , 1 24 24 24 HAUS 4x10 DF#2 +—+ I +_+ (M2) 24 31-1011 01 `r 24 .y+° 24 4x10 E)F 2 `ry' (M4) i' 30 a 5'-8" 21 _�2 2.. 1 cYl aryry I I 4x10 DF#2Tr D5L I JOIST 1 1' -IO" CM3) �� x I —-------�6--�' ----°�-----J I 4x10 D1=112 1I 5THDI4RJ (M2) I I 0 STHD 14RJ 9 I I I I D1 I I I I I I 42 1 i I 3 \ I CONCRETE PATIO AGGREGATE BASE AND REBAR BY OTHERS 4. — /� � I I I — J STHD 14 6'-0' 4" CONCRETE SLAB SLOPE GARAGE SLAB TO A DRAIN OR I VEHICLE ENTRY DOORWAY. CONTINUOUS FOOTING W/ (2) #4 REBAR AT DOOR OPENINGS. +� (15C 406.2.4 -GARAGE FLOOR 5URFACE5) I I 1 7 D1 l��ry+" ------------1 I I —----------- --- ------ 5 STHD 14 16 STHD 14 5 D1DZ STHp 14 D1 14'-3' 23'- 1'-102' W/ S' STEM AT PORTAL FRAME �AIN FL OOFR FF�A�-I f G DO NOT 6C,4LE(1/4" =1') iiia - .. © ' LN�I C---------- :: ----- . I� ��■�� i�� � I /%; mq1 STHD 14RJ STHD 14R,. I I L I I 7 D1 12 i I 1 — — — — — — — ----- D1 5 STHD 14 STHD 14 5 STHp 14 W/ S" 5TE1 W/ S" STEM AT PORTAL F 2 PORTAL FRAME $ _3, 2'-42" 4 24 4x10 DI=#2_ (M2) �6 --------- „+bi STHD 14RJ b r r ;r T 23 n7 . CONCRETE PATIO I AGGREGATE BASE AND REBAR BY r ;ry+ OTHERS r-24- - e Al LL:;f I I I STHD 14 N 0i 45'-0' 1'-10" W/ S" STEM AT PORTAL FRAME / FOUNEDATION FLAN ENGINEEDING HOLDOWN SCHEDULE 51MP50N PRODUCT FASTENERS POSITIVE POST TO FOOTING CONNECTION MODEL NUMBER RX ANCHOR BOLTS NAILS SCREWS CAPACITY" SNOW HDU5 - HF MEMBER 4340" N/A (14)-SDSYa'x 2�' TO (2) STUDS J5 5/9x24 URO. HDU5 - DF MEMBER 5645" EXAMPLES MIN HDU5 - HF MEMBER 5820" N/A (20)-5DSYa x 211' TO (2) STUDS 5ST525 OR 55 7/8'x24 HDU8 - DF MEMBER 7870" HOLDOWN/STRAP MIN. UNO. HDUII - HF MEMBER 8030" N/A (30)-5D5 Ya x2Y, TO 6x6 MIN. 561x30' U.N.O. HDUII - DF MEMBER 9335" DETAIL CALL -OUT POST PER PLAN 1 HDU14 - HF MEMBER 9260" N/A (3(o)-5DS)/4'x 2�' TO 6x(o MIN. 551x30' URO. HDU14 - DF MEMBER 14445" 12K CAPACITY POST PER PLAN N 5THD14/5THDI4R) - 3500" (2) STUDS W/ (30) Ibd N/A N/A M5TC4853 - 3900" PER MFR N/A N/A MSTC6653 - 4490" PER MFR N/A N/A C514 - 2490" (18) 8d EACH END N/A N/A HOLDOWN NOTES: (U INSTALL ALL SHEAR ANCHORS PER MANUFACTURER INSTRUCTIONS (2) ALL METAL CONNECTORS COMING IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE SIMPSON 'Z -MAX', TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED FOR CORROSION PROTECTION. (3) SUBSTITUTION WITH NON-SIMRSON ANCHORS WITH ENGINEER'S APPROVAL. (4) STHD14RJ INSTALLATION AT RIM JOIST LOCATIONS ONLY (RJ=RIM JOIST) LEGEND FOR POINT LOAD KEY POSITIVE POST TO FOOTING CONNECTION MEMBER RX FACTORED DEAD 2.0 6.0 LIV 2BK CAPACITY SNOW 3.0 STUD/COLUMN 24°x24"x6' W/(2) 04 EACH WAY DESIGNATOR ,y+0�' 5BK CAPACITY EXAMPLES POST PER PLAN 30 SHEARWALL DESIGNATOR cul Boa SIUI HOLDOWN/STRAP 30'x30'x10" W/(4)114 EACH WAY DE S IGN4TOR STHD14 ® HDU5 WC514s 0614 It DETAIL CALL -OUT POST PER PLAN 1 36 D1 50U,45H1 BLOCKING O 5TUD(5) FOR POINT LOAD FROM ABOVE O SQUASH BLOCKS) REQUIRED UNDER ALL DBL STUD OR GREATER WHERE INDICATED ON ENGINEERING. FOOTING PAD SCHEDULE FOR 1500 PSF SOIL BEARING POSITIVE POST TO FOOTING CONNECTION 20'DIA. OR 24"DIA. x 0' O20oR24 ® POST PER PLAN 2BK CAPACITY OR 4.0K CAPACITY 24 24°x24"x6' W/(2) 04 EACH WAY X 5BK CAPACITY POST PER PLAN 30 30'x30'x10" W/(4)114 EACH WAY ® 5.5K CAPACITY POST PER PLAN 36 36'x36 "x12' W/(4) 04 EACH WAY ® 12K CAPACITY POST PER PLAN N 42 42"x42'xl2' WK5) "4 EACH WAY 16SK CAPACITY POST PER PLAN -72 60 54 48 48'x48'x12' W/(6) 04 EACH WAY 21K CAPACITY 1111 1 54'x54'x13' W/(1) 04 EACH WAY 21K CAPACITY &0'x60'x14' W/(8) 414 EACH WAY 33K CAPACITY -72"x-I2'x16" W101) 04 EACH WAY 41K CAPACITY POST PER PLAN o POSITIVE POST TO FOOTING W/ S2MA35�OR MB'4 B U.N.O. a Q A. e . REBAR MAT PER ' FOOTING SCHEDULE 3' FROM SOILOSIDES 4 BOTTOM a. G ' Digitally signed by John Hodge Date: 2023.07.27 11:06:46 -07'00' Irsoti;A:o >lca- u n - r -I i� PC �__I - r -I - r -I N 44 Pa Lu � y 0 �a h J ftj � WWW W =Qv BUILDING CODE 2010150 WIND EXP. B 91 MPH SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 PSF ENG. P.E. JOHN H. DATE 01.01.23 REVIEW ZACK C. ANALYST JOE G. SHEET S 1 1 OF 8 SHEETS PROJECT NUMBER 230311 COPYRIGHT ©2023 HODGE ENGINEERING INC. THIS DOCUMENT NAS BEEN DIGITALLY SKIED PER WAC 196-23-070 WITH A GLOBAL SIGN CERTIFICATE. THE CERTIFICATE MA7 BE REMOVED 87 TFE JURISDICTION 2018 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 230311 FOR: RUSH RESIDENTIAL PLAN: VISTA YELM DUPLEX SITE CRITERIA 24" O.C. TRUSS/RAFTERS DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD M DETAIL CALL-OUt CATEGORY 1 OWNER PER OWNER OWNER RESPONSE S1 RESPONSE Ss 25 PSF 97 MPH B D D II <15% NONE NONE 12" 0.4658 1.2868 350 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES EXTEND HEADER OVER PORTAL FRAME PER DETAIL 5/DI VAIL 5HEATHING TO ALL AMINCs MEMBERS U51NG ad W/ 3' GRID PATTERN. INSTALL 5IMP50N L5TA STRAP a BACKSIDE ROWS 16d SINKER /a 3'O.G. to EXTEND HEADER OVER PORTAL FRAME PER DETAIL 5/DI EXTEND HEADER OVER PORTAL FRAME PER DETAIL 5/DI LOUJEfR :;ROof= Uf=f=EfR f=LOO f=fRAt"IING GfRAVIT�' LENGINEEfRING_ DO NOT 5CY4LEN/4 11 = I') ROOF 5HEATHING 5CHEDULE 24" O.C. TRUSS/RAFTERS SNOW LOAD NOMINAL SPAN R,gtlNCx (UP TO) THICKNESS 1'0 6.0 40 PSF 7/16' 24/16 LONG DIMENSIONS PERPENDICULAR TO ROOF JOISt U11tH EDGE SUPPORT. 1�5032.LI(U LEGEND POINT LOAD IGEI' MEMBEREAD RX FACTORED �L 1'0 6.0 V 2.0 SNOW 3.0 SCUD/COLUMN � �' DESICaNAtOR ry+" Q�' EXAMPLES 10 SHEARlUALL DESICsNAtOR � o°a HOLDOUJN/StR4P DESIGNATOR STNDI4 va (zx.6ws c514 DETAIL CALL-OUt 1 D1 PROVIDE ALL FINAL SHOP DRAWINGS TO NODGE ENGINEERING AS SOON AS COMPLETED. IF DESIGNER'S DRAWINGS DIFFER STRUCTURALLY FROM SHOPS ADDITIONAL ENGINEERING WILL BE REQUIRED. INSTALL AND 5R4GE JOISTS AND TRUSSES PER MANUFACTURER TRUSS FASTENER SCHEDULE: A35 g 32' cc OR 5DWC 6 9 16' OG. (TYPICAL AT ALL GABLE ENDS) NI - TYPICAL AT ALL TRUSS TO PERPENDICULAR TOP PLATE LOCATIONS lUN.O.) 12JN2.55 - TYPICAL AT ALL MULTIPLE FLY TRUSS TO PERPENDICULAR TOP PLATE LOCATIONS (U.N.O.) LGT3 - BI (LXR) (LXMXR) DENOTES LEFT, MIDDLE RIGHT TRUSS BEARING. REFER TO BUILDER PROVIDED TRU55 MFR PROFILES FOR ADDITIONAL INFORMATION. ENGINEERED USING BUILDER PROVIDED MFR TRU55 LAYOUT COMPLETED BY THE TRUSS CO. JOB NUMBER M-2021-01, DATED 06.0123. CHANGING TRUSSES INVALIDATES ?H15 ENGINEERING 00 0 Z 0 W w F -4 milmoll rll- L h�q 2 0 wI rte3 Q 0) -'- N 0 tO rr U N �' 7'0N fii •L a) C))a) O a) O cLU q qw�cL L L �':3 �O C U f6 a) N V O V 0 0 N N Q Q N 0 f6 ~ N a) U L L U a) �La)°>.�a) c N� c N c0 0 x'28 70O a >, O Ot.Q Q U U '� U a) j, O NC LO '� a) a) (0-0 U Q -0 BUILDING CODE 2018 I5C WIND EXP. 5 91 MPH SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 FF ENG. P.E. JOIN N. DATE 01.01.23 REVIEW ZACK C. ANALYST JOE G. SHEET z OF 8 SHEETS PROJECT NUMBER 230311 GOPI'RIGNt cQ2023 I-IODCxE ENGINEERING, INC. DIGITALLY SIGNED R U)4G 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ CERTIFICATE MAY BE REMOVED BY T44E JURISDICTION 2018 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 230311 FOR: RUSH RESIDENTIAL PLAN: VISTA YELM DUPLEX SITE CRITERIA 24" O.C. TRUSS/RAFTERS DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD M DETAIL CALL-OUt CATEGORY 1 OWNER PER OWNER OWNER RESPONSE S1 RESPONSE Ss 25 PSF 97 MPH B D D II <15% NONE NONE 12" 0.4658 1.2868 350 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES WHEN RAISED HEEL TRUSS :;RoOf= f=MIN VIT�' LOAD ENGINEEfRING FDO NOT 5CALE(1/4 11 = V) ROOF 5HEATHING 5CHEDULE 24" O.C. TRUSS/RAFTERS SNOW LOAD NOMINAL SPAN R,gtlNCx (UP TO) THICKNESS 1'0 6.0 40 PSF 7/16' 24/16 LONG DIMENSIONS PERPENDICULAR TO ROOF JOISt U11tH EDGE SUPPORT. 1�5032.LI(U LEGEND POINT LOAD IGEI' MEMBEREAD RX FACTORED �L 1'0 6.0 V 2.0 SNOW 3.0 SCUD/COLUMN � �' DESICaNAtOR ry+" Q�' EXAMPLES 10 SHEARlUALL DESICsNAtOR � o°a HOLDOUJN/StR4P DESIGNATOR STNDI4 va (zx.6ws c514 DETAIL CALL-OUt 1 D1 PROVIDE ALL FINAL SHOP DRAWINGS TO NODGE ENGINEERING AS SOON AS COMPLETED. IF DESIGNER'S DRAWINGS DIFFER STRUCTURALLY FROM SHOPS ADDITIONAL ENGINEERING WILL BE REQUIRED. INSTALL AND 5R4GE JOISTS AND TRUSSES PER MANUFACTURER TYPICAL AT ALL GABLE ENDS r15'�TRUSS FASTENER SCHEDULE: D2 A35 9 32' cc OR 5DWC, 6 g 16' OC. (TYPICAL AT ALL GABLE ENDS) NI -TYPICAL A7 ALL TRUSS 70 PERPENDICULAR TOP PLATE LOCATIONS l UN.OJ (2)H25s - TYPICAL AT ALL MULTIPLE PLY TRU55 TO PERPENDICULAR TOP PLATE LOCATIONS (LI.N.O.) LGT3 - Bl (LXR) (LXMXR) DENOTES LEFT, MIDDLE RIGHT TRUSS BEARING. REFER TO BUILDER PROVIDED TRUSS MSR PROFILES FOR ADDITIONAL INFORMATION. ENGINEERED U51NG BUILDER PROVIDED MFR TRUSS LAYOUT COMPLETED BY THE TRUSS CO. JOB NUMBER M-221-09, DATED 6.123. CHANGING TRU55E5 INVALIDATES THIS ENGINEERING 00 0 Z 0 W w F -4 milmoll rll- L h�c 2 0 wI rte3 Q 0) -'- N 0 tO rr U N �' 7'0N fii •L a) C))a) O a) O cLU q qw�cL L L �':3 �O C U f6 a) N V O V 0 0 N N Q Q N 0 f6 ~ N a) U L L U a) �La)°>.�a) 0 0'c5) N� c Nc 28 7 O 0 a >, O Ot.Q t N O U ca '� a)� N v 0 cn !�c� Q U U '� U a) j, O NC LO '� a) a) cn (0-0 U Q -0 BUILDING CODE 2018 I5C WIND EXP. 5 91 MPH SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 FF ENG. P.E. JOIN N. DATE 01.01.23 REVIEW ZACK C. ANALYST JOE G. SHEET 3 OF 8 SHEETS PROJECT NUMBER 230311 GOPI'RIGNt cQ2023 I-IODCxE ENGINEERING, INC. DIGITALLY SIGNED R U)4G 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ CERTIFICATE MAY BE REMOVED BY T44E JURISDICTION 2018 IBC LATERAL ANALYSIS AND GRAVITY LOAD ENGINEERING PROJECT NUMBER: 230311 FOR: RUSH RESIDENTIAL PLAN: VISTA YELM DUPLEX SITE CRITERIA 24" O.C. TRUSS/RAFTERS DESIGN WIND WIND (IBC) SEISMIC SITE SOIL RISK SLOPE SPECIAL SITE GEOTECH FROST SEISMIC SEISMIC APPROX. ROOF SNOW SPEED EXPOSURE DESIGN CLASS. CATEGORY PER CONDITIONS REPORT PER DEPTH SPECTRAL SPECTRAL ELEVATION LOAD M 551x30' U.N.O. CATEGORY (HF x 0.93) SU11 OWNER PER OWNER OWNER d Is ' O.C. 16 6 RESPONSE S1 RESPONSE Ss 2601365 25 PSF 97 MPH B D D II <15% NONE NONE 12" 0.4658 1.2868 350 FT VALUES OBTAINED FROM JURISDICTION, STATE, AND NATIONAL AGENCIES EXTEND HEADER OVER PORTAL FRAME PER DETAIL 5/DI vain 5HEATHING TO ALL AMINCs MEMBERS USINCs Sd W/ 3' GRID PATTERN. INSTALL SIMPSON L5TA STRAP 9 BACKSIDE ROWS 1(od SINKER 0 3110.C. SB 5/044ANCHOR BOLT REQUIRED AT ALL NDU5 HOLDOU,N LOCATIONS. TYP 5/DI Frao FTAO HEADER OVER PORTAL FRAME PER DETAIL 5/DI ING ti I N -4 1 DO NOT 5CY4LEN/a 1') SHEATH ALL EXTERIOR WALLS AS CJui i UNLESS NOTED OTHERWISE. ADJUST CRAWL SPACE 1IENT6 TO BE 12' MINIMUM AWAY FROM H0LDOUINS 3'o.c. NAILING - CONTINUOUS SHEATHING OVER MUD 5ILL TYPICAL ALL EXTERIOR WALLS DO NOT 5CALE(]/& 1') SNEAtN ALL EXTERIOR WALLS AS CJwi UNLESS NOTED OTHERWISE. ]ROOF 5PEATHING 5CHEE)ULE 24" O.C. TRUSS/RAFTERS SNOW LOAD NOMINAL SPAN R,gtlNCs (UP t0) THICKNESS ANCHOR BOLT 40 PSS 1/16' 24/16 LONG DIMENSIONS PERPENDICULAR t0 ROOF JOIST U11TN EDGE SUPPORT. R5032.I.IfU SHEAR WALL NY41LING SCHEDULE 11 ed = 2-1/2' x 0.131' SIMPSON PRODUCT FASTENERS NAIL SIZE 4 STUD 4 2x 50TTOM DBL TOP ANCHOR BOLT I CAPACITY(PLF) SHEAR WALL APA RATED SPACE a 5LOCKING s PLATE TO PLATE TO RIM TO CONCRETE 5EI5MIC / WIND LABEL SHEATHING EDGES ADJOINING RIM BELOW J015T BELOW (DF VALUES) MIN. U.N.O. HDUII - HF MEMBER 80300 EDGES (30)-$D$ J/4'x2 2- TO 6x6 MIN. 551x30' U.N.O. HDUII - DF MEMBER 93350 (HF x 0.93) SU11 1/16' OSB ONE SIDE Sd Is 6' O.C. 2x STUD d Is ' O.C. 16 6 (2)16d a 16 IO.C. 5/6' a 46' O.C. 1/21 a 36 1 O.C. 2601365 5THD14/5THD14RJ - 3500* (2) 5TUD5 UJ/ (30)16d N/A N/A M5TC4853 - 39000 PER MFR 5u12 1/1(01055 ONE SIDE ad Is 4' O.C. 3x STUD (2) 2x STUD 16d a 4' O.C. (2)16d Is 16 IO.C. 5/8' ,s 40' O.C. 1/2 281 OC. 360 / 532 N/A N/A or SU13 A 1/1(01065 ONE SIDE Sd a 3' O.C. (2) 2x STUD 16d a 4' O.C. (2)�16d Is 16 O.C. 5/8� 24' O.C. 112's III O.C. 41301685 sup A 1/1(01055 ONE SIDE ed 6 2' O.C. (2) 2x STUD 16d a 4' O.C. LTP4 a 16' O.C.5/8' 0 21' O.C. 1/2 -9 15 O.C. 64016135 Sud A 1/1(01055 50TH 51DE5 ed a 3' O.C. (2) 2x STUD 16d a 4' O.C. LTP4 e 16' O.C.5/8' tv 12' O.C. 112',s 8 O.C. 980 / 1310 SHEAR WALL NOTE5: (1) INSTALL PANELS VERTICALLY (2) WHERE SHEATHING 15 APPLIED ON BOTH SIDES OF WALL, PANEL EDGE JOINTS ON 2X FRAMING SHALL BE STAGGERED 50 JOINTS ON THE OPPOSITE 51DE5 ARE NOT LOCATED ON THE SAME 5TUD5. (3) BLOCKING 15 REQUIRED AT ALL PANEL EDGES. (4) PROVIDE SHEAR WALL SHEATHING AND NAILING FOR THE ENTIRE LENGTH OF THE WALLS INDICATED ON THE PLANS. ENDS OF FULL HEIGHT WALLS ARE DESIGNATED BY EXTERIOR OF THE BUILDING, CORRIDORS, WINDOWS, OR DOORWAYS OR AS DESIGNATED ON THE PLANS. SEE PLANS FOR HOLDOUJN REQUIREMENTS. (5) SHEATHING EDGE NAILING 15 REQUIRED AT ALL HOLDOUJN POSTS. (6) INTERMEDIATE FRAMING TO 5E WITH 2X MINIMUM MEMBERS. FIELD NAILING 15 12' O.C. UNLESS NOTED OTHERWISE. (1) BASED ON 0.131' x 1-1/2' LONG NAILS USED TO ATTACH FRAMING CLIPS DIRECTLY TO FRAMING. USE 0.131' x 2-1/2' LONG NAILS WHEN NAILING THROUGH SHEATHING. (8) DBL STUDS MAY BE USED IN LIEU OF 3X MATERIAL (9) WHERE PLATE ATTACHMENTS SPECIFY (2) ROWS OF NAILS, PROVIDE DOUBLE JOIST, RIM OR EQUAL. ATTACH PER DETAILS. (10) ANCHOR BOLTS SHALL BE PROVIDED UJ/ STEEL PLATE WASHERS y' x3' x 3', EMBED ANCHORS A MINIMUM OF 1' INTO THE CONCRETE. (11) PRESSURE TREATED MATERIALS CAN CAUSE EXCESSIVE CORROSION IN THE FASTENERS. PROVIDE HOT -DIPPED GALVANIZED (ELECTRO PLATING NOT PERMITTED) NAILS AND CONNECTOR PLATES (FRAMING ANGLES, ETC.) FOR ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED FRAMING MEMBERS. (12) AS AN OPTION TO FRAMING CLIPS SHEATHING 15 TO EXTEND FROM MUDSILL TO TOP OF DOUBLE TOP PLATE FOR SINGLE STORY, AND FROM MUDSILL TO MIDDLE OF STRUCTURAL RIM FOR TWO (+) STORY STRUCTURES. SEE SHEAR NAILING BUILDING SECTION DETAIL. (13)15/1' PLYWOOD SHEATHING MAY BE USED IN PLACE OF THE Y1 055 SHEATHING PROVIDED THAT ALL STUD SPACING 15 16' O.C. MAX. (14) 5U5 $HEARWALL REQUIRES 4-1/2' PLATE WASHER (15) $HEARWALL DESIGNATED WITH AN ASTERISK ($) MAY BE SHEATHED WITH PERFORMANCE CATEGORY 1/16 SMART PANEL Tl -I1 OR 5/16 HARDIE PANEL (16) SIMPSON MASAP (STANDARD INSTALLATION) MAY BE SUBSTITUTED FOR ANCHOR BOLT. USE 1/2' A5 SPACING HOLDOWN 5CHEDULE SIMPSON PRODUCT FASTENERS MODEL NUMBER RX ANCHOR BOLT$ NAILS 5CREW5 CAPACITY# SNOW NDU5 - HF MEMBER 43400 N/A (14)-SDS)/4'x 2Y' TO (2) STUDS 55 5/844 U.N.O. HDUS - DF MEMBER 5645* MIN. U� HDUS - HF MEMBER 58200 N/A (20)-SD6 Y'x 2Y' TO (2) STUDS $5T528 OR $51/8'x24 HI - DF MEMBER 18100 MIN. U.N.O. HDUII - HF MEMBER 80300 N/A (30)-$D$ J/4'x2 2- TO 6x6 MIN. 551x30' U.N.O. HDUII - DF MEMBER 93350 1 HDU14 - W MEM5ER 9260* N/A (3(o) -SDS Y4'x 2V2' TO 6x6 MIN. 551x30' U.N.O. HDU14 - DF MEMBER 14445* 5THD14/5THD14RJ - 3500* (2) 5TUD5 UJ/ (30)16d N/A N/A M5TC4853 - 39000 PER MFR N/A N/A MSTC6653 - 44900 PER MFR N/A N/A C514 - 2490* (18) Sd EACH END N/A N/A HOLDOUJN NOTE5: (l) INSTALL ALL SHEAR ANCHORS PER MANUFACTURER INSTRUCTIONS (2) ALL METAL CONNECTORS COMING IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE SIMPSON 'Z -MAX', TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED FOR CORROSION PROTECTION. (3) SU55TITUTION WITH NON-51MPSON ANCHORS WITH ENGINEER'5 APPROVAL. (4) STWD14RJ INSTALLATION AT RIM JOIST LOCATIONS ONLY (RJ =RIM JOIST) LEGEND POINT LOAD IGEI' MEMBER RX FACTORED DEVD Z.O 6.0 SNOW 3.0 SCUD/COLUMN � DESIGNATOR EXAMPLES U� SHEARUJALL DESIGNATOR � O HOLDOUJN/STRAP DESIGNATOR STHDI4 t2k;614s C6I4 DETAIL GALL-OUT 1 D1 00 Z 0 W w L c'c') rr UN O �' 7(C;N fii •Lw co c 13) a) a) .Z5LO C) O a)J a) L c c U � a >�L-ooc�. f6 a) N V 0.— c Va � ° c f6 ~ N a) U L L U C 2a)°>.ca) eco 0caN'7CO0 B E cE .�'� O , a > O O � Q v 0 �Ec� Q :3 a � � a) Q U U U-0 a) j,O c a o a) a c0 N -0 U Q -0 BUILDING CODE 2018 IBC WIND EXP. 5 91 MPH SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 P5F iiiiiiiiiiiiiii ENG. P.E. JOIN N. DATE 01.01.23 REVIEW ZACK C. ANALYST JOE G. SHEET 4 OF 8 SHEETS PROJECT NUMBER 230311 GOPI'RIGNt cQ2023 I-IODCxE ENGINEERING, INC. DIGITALLY SIGNED R Ub4G 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ CERTIFICATE MAY BE REhIOVID BY T44E JURISDICTION EXTENT OF HEADER UJ,�TEIz HEATER D .0 DOU5LE PORTAL FRAME (TWO BRACED PANELS) � FOR SHEAR MIN. 3"xlli" NET � � FOR A PANEL SPLICE (IF SHEATHING PER ROOF EXTENT OF HEADER HEADER REQUIRED. (MAY 5E NEEDED) PANEL EDGES SHALL SHEATHING SCHEDULE. SINGLE PORTAL FRAME (ONE 5RACED PANEL) ,� - ,� � WATER HEATER SEISMIC ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° LARGER) 5E BLOCKED, AND OCCUR WITHIN STAGGER SHEETS UJ/ 1/6 ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° 1=STEN SPIE �4T�1 ING TO �IE,�DE lz 2 4" OF MID - NE IGHT ONE ROW 01= STRAPS LOCATED 1/3 ,�UJ,�ir � ° o ° � � MIN GAP. EDGE CLIPS z OI d I° TYP. SHEATHING TO FRAMING � RECOMMENDED FOR 24/1 FROM TANK CAP AND S,�SE. 3 ° d ° UJ/ ad COMMON OR GALVANIZED 0 I I NAILING 15 REQUIRED. IF 2x4 ° ° ° SOX N4IL5 IN 3' GRID PATTERN RATED SHEATHING WITH Mn LAG BOLT PER SEISMIC z 01 g 2 0 0 10 II 5LOCKING 16 USED, THE 2x4'6 •: MAXIMUM SPAN 2� INCHES 5 AS SHOWN AND 3 O.C. IN ALL W STRAP MFR ANCHOR INTO O 01 � 0 1° MUST 5E NAILED TOGETHER WITH pC 2X STUD 4 PLACES °� 00 ° ° ° ° ° - 0 0 0 0 ° 0 ° ° 1=1z,�MfNG (STUDS, 5LOCKING, � ad NAILS 6 (o" O.C. AT °° °° °°° °°°°° °°° ,�NDSILLS)T'rP. (3) l(od SINKERS. 010000 000 00000 0010 51RD5LOCKING 2 DRYWALL PER PLAN ° ° ° ° ° ° ° ° � � � (2) CONTINUOUS 04 RE5AR AT 0I o 0 0 0 0 0 0 0 o 0 0 0 0 0 0 oIo SHEATHING SRE,�K •• 010 0 0 0 0 0 0 0 0 0 0 0 0 0 0 010 FASTEN(3) OP PLATEO HEADER FOOTING. • �01 2X STUD WALL 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 UJ/ TWO ROWS OF 16D SINKER #� � �." � OM TO ��• :. .•• EXTEND UJ,�LL SHEATHING 00 00 00 0o II RE5 I� W (D (D (D 3 I I NAILS 3 O.C. Tire. , TO TOP OF DOUBLE TOP 3 �, 00 00 00 00 12 O.C. �o VENT FLUTE 1�3_ 010 ° ° (BACKSIDE) (BACKSIDE) � (BACKSIDE) ° ° � � 0 10 � L5TA18 STRAP (5ACK51DE). USE II PLATE a j s STEM uu,�LL 010 0 ° 0 0 010 3 LONGER SERIES To EXTEND To ' 2 010 °1° I °I° ° ° ° ° ° ° °I° REQUIRED SIMPSON H1 EACH TRUSS ® ANCHOR 5, 5E TO WALL � ° ° ° ° � � � ° ° ° ° ° ° ° 0 ° ° TOP OF PONY WALL, IF PRESENT. . I I I I I � OR RAFTER oIo oIo I °lo oIo DESIGN VALUES INTERPOLATED • 0 \ • PERPENDICULAR TOP o (4)�, FROM APA TT -100H TA5LE 1 - z _ .. .. .. .0 . .0 . PL,TE INTERSECTION UN.O. • goo • x :: :: :: :: :: FOR NARROW PORTAL WIDTHS � ® (2) H2.5A FOR MULTI PLY .. .. .. .. :I PLAN VIEW :: :: :: :: :: • • . • . • • • • • • � MIN. (2) 2x� (,ALL DM) OR (2nx� •3 .. .. .. . I . • MFR TRUSSES 6 24" O.C. UJ/ 70 3If : If2 II • • PLAN ROOF SHE ATH I NG = � � � q. C C �-I- 0.I- N 1/1 055 SHEATHING MIN. ~� ' .. .. . • . NAIL W1 ad 6 � O.C. FOR `�� ���N�° ��0 • i • i i • i • i • • • • II i 4% N O i ' If : If .. .. .. .. .. 5THD 14 (UN.O ON PLAN) ' • ' • PANEL EDGES AND 12 O.C. � � � O N Y X • o 0 0 0 0 0 0 • !.� • • 0 0 0 0 0 0 0 0 • IN FIELD Q'— N 0) C L O O 2 0 0 0 0 j 1 0 0 0 0 0 0 0 0 • • • j L N N ~- S' STEM WALL HEADER EXTENDED OVER °' ` ° C i6 O O N U i i U C Z. _ — — o0 0 REQUIRED SHE,�RUJ,4LL • . ' • SHEATH ,ALL GA5LE ENDS � _ = o � � Q � 9 d• o a) O � a • , ... ... x � 'gin c >, a v O ° N c v. d' d. p.p. °. o E L L a z c c N m O 0 a •v D• ° O v� ° O O t U N L N A v o ° ° o ° ° r II • • U51NG 5W1 5H A WA � N ( C' E C —— a. o ,�NCHORSOLTUJ/IEMBED L� o a o —'' SECTION II r II II p ���0��N,N SCHEDULE Q o v. d av 4ddv. v 4• �° v° ° �. o° _ o° o , UJ/ MIN 3x3 x.229 PLATE WASHER _ _ . L 0 cc 0 C N ri0 IBC FIGURE 2308:652 4 D5L 50TTOM PLATE 5 1 WATER HEATER 5TRAFFING D1 PORTAL FRAME D1 ROOF &HEATHING D1 ad o (:D �•x4 P05T UNO. GUSSET o GIRDER SPLICE. / 1(od 2x SOLE PLATE TO RIM , P.T. POSTS IF LE55 THAN S" FULL DEPTH GUSSET EACH UJ/lid PER SHE,4Rl�J,�LL W a / �� 3 1 CUT TOP PLATE OR DROP � SCHEDULE �, 12 FROM 501L s IDE (10)10d. MIN 4X(o POST o SEAM DO NOT CUT SEAM / S II -8 .. $ II \ 9 ad 'm � o.C. 50TTOM PLATE _ • � 3/� T �G SUSFLOOR ad NAIL j TA OST CONNECTION: 2 II � o � 2 DoUSLE TOP PLATE � LLPAND GLUE To JOISTS. STS. ® Root= FRAMER PER Roof= To 3/� FLOOR SHEATHING ING o M � � a o 21 GU55ET ONE 51DE ONLY FRAMING DETAIL ,�N F CORTO IM . � O.C. @ PANEL EDGES ® D L R SIMPSON 5T22 OR 22 C514 WIDTH OF POST W1 (S)10o1 2 � u 10 O.C. MELD NAILING. � 3 FLOOR JOIST . UJ/(18)104 OR DROP SE,�M UJ/ - - I I ® ROOF SHEATHING PER � -S POST CONNECTION: 5LOCK ALL 5EARING. FACE 2 . Root= SHEATHING 2 RIM To TOP PLATE WITH CONTINUOUS TOP PLATE. - GU55ET 50TH SIDES WKIO) GRAIN AT RIGHT ANGLES TO ./ � STRAP M,4'r SE PLACED ON - - SCHEDULE l(od AT S' O.C. (U N.O.) 10d NAILS. 45 DEGREE 2X4 JOIST. • 51DE OF TOP PLATE II TOENAIL J015T TO TOP LATERAL 5RACE WI(4)l(od 5IMP60N EP5, P5, (2)A35s ` — / 1/1� 0.5.5. SHEATHING � • � � )PLATE E,�CH 5fDE(6) l(od NAILS �_� OR MA5 W12x HF #2 STUDS AT� • � � S 12 POST CONNECTION: . � 16" O.C. (UN.0) W/Sd NAILS ad SHEATHING TO STUD � (2) lid N,41L5 1�" O.C. CRO55 5RACE WITH 2X4 AS S DO NOT CUT INTO 4S r / o , � -rI 3/S MINIMUM EDGE PER 5HEARWALL SHOWN WKE )1(od EACH END. DEGREE SHEAR CONE OF 3 � 3 / o 5E AM PER PLAN ,ADD 4X4 BLOCK 5ETWEEN UND ISTURSED SOIL DISTANCE SCHEDULE � WI(4)1(od EACH SIDE � � D5L 2X TOP PLATE 4 TOP • 2X CRIPPLES ' � .: � MID -SPAN SPAN � STRUCTURAL 1-1/411 RIM PLATE To STUD uJ/(2) • 1(od Is 1(o' O.C. o, • S g PLYWOOD FILLER � � 2x STUD (AS REQUIRED) ° � 3/4 T 4G 5U5 FLOOR 4� 9 HEADER PER PLAN _ / j j 9 MULTIPLE STUDS FOR ° POINT LOAD FROM A50VE 9 / � FLOOR J015T PER PLAN (2) lid N,41L5 �o � SQU,�SH BLOCKS DOUBLE 2X TRIMMER STUDS •. FLOOR TO FLOOR REQUIRED UNDER ALL MIN. FOR > (o' OPENING UNO. - CONNECTION PER PO LOADS / o S SEPARATE FLOOR TO RIM 50ARD TO FLOOR NO STRAP REQUIRED IF •.• ••' • • •�o FLOOR CONNECTION J015T WITH (2) l(od CONTINUOUS TO AT •. ' ' / P PL E DETAIL 11 ... � � 2 CONTINUOUS FULL HEIGHT 5EAM ANDHEADER 5UPPOIRT D1 = _ �/ S FLOOR TO FLOOR CONN CTION � VERTICAL 058. SRE,�K — — 9 . • 5ETWEEN TOP PLATES � AND EXTEND DOWN OVER � 2x STUD WALL PER PLAN • / MUD5ILL (I CONCRETE 5LA5 PER PLAN FOOTING co ,ILL PANEL �, <• DG O LANDING O 3 VAPOR 5ARRIER 9d' . 2x MEM5ER •. •. � PER PLAN 4 (D (DFOOTING CORNER oe TOP/BOTTOM PLATE To j � 2x PT uJ/ ,ANCHOR SoLTS J H A A H J STUDS UJ/ (2) lid THRU � PER 5 E RUJ LL SCHEDULE ,w r r NAILS TYP. (3) l(od THRU W •: \ r " FOOTING CORNER FOOT ING T 2 STEMUJ,LL CORNER #4 HORIZONTAL 3 -� FROM W 10 11 NAIL FOR 5W3, 5W4 4 5W5 z R L R •41 _� TOP OF STEM AND a6 12' O.C.S . . • • SHEAR U1,�LL5 � ° • . . r i ad 0 24" STEM SHOWN ® 30" MINIMIUM LAP SPLICE.. / \\ 2x PT MUD S ILL WITH � _ 116/1 -R , . � //\\i/\\i/\\i� � II 11 ;�\�\\��\��\�\\��\�� �, \�\\�\\��\� �o #4 VERTICAL DOWELS 6 3( � ,ANCHOR 5OLT5 PER 1 -� %�\\�\\�\\�\\/ O.C. IF COLD JOINT, / 1 1 � • \ \ -\\ . EXTEND TO 3 OF THE VERTICAL RE5AR NOT \ SHEAR WALL TA5LE j. d , II SHOWN FOR CLARITY / (MIN OF 2 PER PLATE 4 !\\ � •'' \\//\\ \\//\\//� � PERSPECTIVE OVERVIEW � WITHIN 12 OF ANY i o, /\�,� FOOTING 5A6E. EXTEND II ,�/i/ �" \\i � 14' MIN, INTO STEMUJ,4LL CORNER) MIN FROM �• «-- \i\ \\i TYP (U N.0) �• EDGE.00 d — v a — — . ° .a .•.� i-1 11= I I=1 I I=1 I I=1 I I=1 I I=1 I I� ,III=I I (2) #� CENTERED IN 3(4)\ SLA5 oN GRADE WHERE--_III--II-1 I I E ERED.. j2 S FOOTING 2 MIN / a a / SPECIFIED PER PLAN °J a \ BUILDING II r • •. D • • • • _ • v ' S FOOTING AND ROOF CODE 2 015 15C STEM WALL CORNER STEM WALL T •, . • DROP JOISTS WHERE , D ' ' •� a � � . j � MIN. FOUND,4T I ON D IMEN510N DR�41NS f � REQUIRED D SPECIFIED PER PLAN WIND •' NUM5ER OF FLOORS WIDTH THICKNE55 WIDTH v • . • SUPPORTED 5Y FOOT ING OF FOOT ING OF FOOT ING OF 5TEM 9 N,�T I VE UND I STUBBED 50 I L EXP. 5 91 MPH D • . D 4 a v 1 FLOOR 12" OR STRUCTURAL FILL PER SEISMIC DESIGN , v. 12 / 13 / .. a • � . 2 FLOOR ��11 � II � II GEOTECH CATEGORY D ' • ` p ` C 3 FLOOR 1Q11 QII QII a 1 FROST DEPTH 5Y ROOF SNOW JURISDICTION LOAD 25 P5F 12 8r6"' ISc TA5LE is09.1 3 CONCRETE CORNEIR5 D1 P05T TO 5U5FLOCIR GIRDER CONNECTION D1 5HEAR WALL NAILING 4 5UILLDING 5ECTION D1 FOUNDATION WITH 5LA5 D1 2x STUD WALL PER PLAN ENG. P.E. (DFLOOR JOIST OR 1 JOHN H. LANDING DRIVEWAY AY APPROACH PER � 3/4 T 4G 5U5FLOOR (UN.O.) DATE r 1 1 ; ARCHITECTURAL SHEETS 01.0123 � 2X� LEDGER UJ(2) 104 � 2 2 FLOOR JOISTS PER PLAN REVIEW . O.C.(D 2x � 16 cc • • (3) 2X12 STRINGERS • 2 GARAGE sL,�S PER PLAN Z,�CK C. � FLooR GIRDER PER PLAN 4 ' • . 5-1/2" MINIMUM MATERIAL � • 2 GAP PER DESIGN ANALYST DIAGONAL 5ETWEEN R15E 1owlpop � � FULL DEPTH 5LOCKING JOE G. 3 CONTINUOUS RE5AR REQUIRED AT ALL 5EARING SHEET AND RUN 3 PRESSURE TREATED o PERSPECTIVE (RECOMMENDED FOR 15C 2308.4.(o r 3 UPPER FL IGHT OF STAIRS R5 MU 51 W1 5/S ANCHOR � CRACK CONTROL) � D LL R . o cR c co RoL � . SUPPORTED ON 3/4 T4G 5OLT SPACING PER PLAN. - � �0 2x PT UJ/ ,ANCHOR 5OLT5 11 r PER 6HEARWALL SCHEDULE ad NAILED O.0 COMPACTED 6AND/GRAVEL \i /\i\i\/i\/i\/i 2 x• i\\/\\/\\/\\/\\/\\/\\/\ Z II (o PANEL EDGES 12 O.C. # RESER �II FROM TOP. #� o 0 0 lu ;\\//\\//\\//\\//\\//\\//\\// #�• HORIZONTAL 3 -511 FROM S FIELD • ' ° _ %moi\�i\�i\�i\�i\�i\moi II HORIZONTAL RE5AR - � � �i i i\i i\i\i\ I�• ? TOP OF STEM AND 12 O.C. .. � .. • , • . CONTINUOUS SUfLDING -� ,�,� /,\i/ // // // // // a � � \\\\\\\\\\ ��. � r 2 X� THRUST 5L OCK UJ/10d - SPACED 12 oc g %i/\i/\i/\i/\ , 24' STEM SHOWN 50 F8 SHEETS �o ° . o FOOTING PER FOOTING NG , \\/ . \\/� S o �o O.C. NAIL TO LANDING - /\/ \ '. DETAIL �!\\ 11 04 VERTICAL DOWELS a6 1 II 9 J015T . � � , � . •' . ' • ' . ,/ g VER L D EL PROJECT NUMBER 5LA5 ON GRADE PER PLAN \ � � ���O.C. IF COLD JOINT. EXTEND •(i)3/4' TG SUSFLooR � Ho ou�N ,�N iL--- 230311 LD PER PL o �o \//-- TO 3" OF THE FOOTING _ d • (2) #� RES,�R BOTTOM of 3 2X8 LANDING JOISTS • 1 — _ _ _ — _ _— S,�SE. EXTEND 14" MIN. • S � � �� -1 11= 11=1 I I—III—III—I 11=1 I I_I I I_ I I v D FOOTING - 3 COVER —� . � —I 11=1 III -1 I I=1 I I -III -III INTO .O 104 � O.C. RIM TO ° D ARO STEM 10 FOR 2 x�• UJ,�L L .,� /�\ /, \ \ \ \ . , D D D j 2 g FRO5T DEPTH Sir w 23 j TOP PLATE VERTICAL ,4 2�/\/\/\/\ �- VER L RE5 R / / / / , uu,� \/\/\/\/\ JURISDICTION s �� LL 12 FOR 2x� UJ,�LL O.C. EXTEND TO 3" \ \ \ \ \ L5C AT TOP 4 A3Ss �\ \ \ \ o _ z o 50TTOM CLEARANCE FROM SOIL ,�T �j / / : - MIN. FOUND�4TION DIMENSION j (2) 4 CENTERED IN FOOTING NOTCH STRINGER TO REST BOTTOM OF FOOTING. SECTION i E\/\ . 11 II . / � . � . • . � . . • SUPPORTED ��' FOOT ING OF FOOT ING OF FOOT ING OF 5TEM 11 FOOT ING AND ROOF 37886 a � STRINGERS SPANNING OVER ON LEDGER N EXTEND 1� MIN INTO STEM p II II II DRAINS IF REQUIRED �'o,� F� STE_ (o STEPS MUST 5E SUPPORTED FOOT ING 22 WALL. TYP (UN.O.) 1 FLOOR 12 II � II � II :3/ON III �j /,, �j 2 X TREADS WI(3) 10d � 2 FLOOR 1 � (o (o NATIVE UND 15TUR5E D SOI L W/TX�G/ SE,�M ON �XT POSTS. 12 � II II II 12 POST TO 18" CONCRETE FOOTING EACH STRINGER 3 FLOOR 18 S S OR STRUCTURAL FILL PER OR STUDWALLn 7 GEOTECH COPYRIGHT ©2023 r13 7 / I15C TA5LE 1009.1 4 HODGE ENGINEERING, INC. t�IIS DOCUMENT BIAS BEEN DIGITALLY SIGNED PER 5TAIR LANDING CONNECTION D1 FOUNDATION FOOTING AT PARTY WALL D1 CONTINUOU5 5TRIFFOOTING AT GARAGE ENTRY D1 FOUNDATION WITH FLOOR J015T& D1 WAC 1%-23-070 WITW A GLOBAL SIGN CERTIFICATE. T14E CERTIFICATE MAY BE REMOVED BY THE JURISDICTION 26 J � UNR�STRAIN�D RETAINING WALL SCHEDULE 122 1g �� \\ O MFR CxABLE END TRUSS 14 n � - �F/SP / N U t vERTICAL B K D "MINLgP�RpLq PLATE SPLICE. O FLOOR JOISt PER PLAN _ O DOUBLE 70P PLATE (UN.O. ON PLAN) n r-nr.itir.0 ins ic, �.corir-ni C OU FACS OF FOOTING AND SItE lUOi�IG ARE THE RESPONSIBILItI' OF THE BUILDER 2 70P OF SLOPS AND CIVIL/Cx�Ot�CNNICAL ENC�IN�ER. O HIOA Z O N1OA-2 � D SURROUNDED BY WASHED PEA -GRAVEL OR GRANULAR FILL WITH LE55 THAN 5% FINES. PLACE LGT3 - SD 52.5 (3)PL Y � '3: ' ' •' ' ' ' 6'I' -s' s' 12' �5 a Ire' oc 4�'-9' 7' 4�' s'I'-Ire s' 12' S G 9' oc 6'-3' 14' 1-3/4' U N ,�T�IIN �v V 0 � 6' uu,�LL VERTICAL ,�T 1-3i4" FROM FACE � 2 D f ,4P�IR,4C�M OPENING S � � O �� � SLS — 3 H/3 IBUT NEED NOT > PER PLAN 1=R MINC UNLESS A GEOTECHNICAL REPORT 15 PROVIDED TO EXCEED �0' MAX W U- _ ° cONCR T Cf c� 2500 psi HORIZONTAL RE5AR HODGE ENGINEERING THE SEARING SOILS ARE ASSUMED REIBAR Cf = 60 ksi 114 RESAR AT 10"Oc 3 1(0" OF 5LOCKING UJ/ 36" a TO 5E 1500 P5F OR 2000 PSF. WHEN PROVIDED, FOLLOW 1/� x� S25 SCREW ,4T 1� A551 KIL= 250 cf 4 TOE OF SLOPE _ p C514 STRAP ® O.0 TOP PLATE TO TRU55 ,4 I CT I ON 01= TSI OT CSN I C,4 O �. � ,4CT1� SOIL - 35 pcf N # LL D � � CSE � L REP R SOIL SEARING = 1500 sf 2 ,� SPLICE 30 1=oR a oTTOM CORD p A A N/2 5UT NEED NOT ��� R, 38 OR �5 RES � o S�IE,�T�I I NCS PLN = WITH FOOTING RE5►4R EXCEED 15' MAX � ° 5 TOENAIL TRU55 TO TOP a ° 3 #4 PEEL RE5AR S 12" OC. � PLATE WITH (1) 6d AT I(o j FACE OF STRUCTURE o LL D (6'-10' WALL VERTICALS 2 5EAM/D5L JOIST PER PLAN ON CENTER O 1-3/4" FROM SOIL FACE) 5ACKF I LL WITH 12" MINIMUM FREE AROUND OPENING (TYPICAL HGA10 OR A35 AT 32 O.C. 2 . � DRAINING SOILS. 12' 01= DRAIN � PLACES) (u 1�.0. ON PLAN) � o � ALTERNATIVE To NOTE 4 ° FILL UJ/FILTER FA15RIC z � 525 SCREWS � �o 5LOCKING FOR STRAP 0 2 KEY (NOT REQUIRED IF 5LA5 � NOTES LL PRESENT AT 1=OOTING) o -INSTALL SCREWS UPWARD _ 2? �c m ,, L L �ai 2o �j FOOTING 12' MIN 5ELOW GRADE. THROUGH TOP PLATES INTO 4 � Q '� ° o100 ;� cn N .0 � p .ELOUJ GRADE 15 NOT CENTER OF 50TTOM TRUSS .- �, I I3 i V L CocO C REQUIRED IF 5LA5 PRESENT 5 ° ° ° C�10R2. N;o— J >����. O N Y — N N NO N-- O FOOTING RE,�R # 10" O.C. c� W o 1 T FOOTING TO �E�4R ON -5RACE TRU55E5 PER 5C51. _ o r m a) - WITH 3" COMER ANN Z ���o�a��o FIRM UND ISTUR5ED CONSULT TRUSS MANUFACTURER _ (j) C= z C= L Q NATIVE SOIL OR 6 KE'�UJ,�'� RE13,�R TO MATCH FOR 5RAC I NCS REQUIREMENTS. Q o o (n� N 5 ENGINEERED FILL VERTICAL RE15AR SPACING Q U U U-0 N� >, N N C '� N 15C 180122 26 22 18 113C FIG 16081.1 14 UNIREFRAINELD CONCRETE WALL - 40 FF 5URCHARGE - 201a I 22 LARGE DOPENING q2,)GA5L E END TO SHEAR JAL L ATTACHMENT�D2)FOUNDATION CLEARANCE FROM SL OPE S�D2 s o _ FASTENER PER PLAN � a ao � DRAINAGE - EXTERIOR GRADES ,ADJACENT TO THE WALL5 OF THE MOUSE ,ARE TO E3E SLOPED 2 STUD To MATCH GIRDER PLS (u.N.o $ � � (D(2) 2x4 LAMINATIONS UJ/ (1) � (6) lid NAILS STAGGERED AWAY FROM THE STRUCTURE TO ACHIEVE 5URFACE DRAINAGE. 5U55URFACE DRAINS AT OR ; z ° ° ON ENGINEERING SHEETS) � � � � o � N ROW OF STAGGERED 10d ,�T E�4C�I SIDE 01= TOP � � ° ° � ' � .- ARF_ FOR ANY E3A5F_MF_NT OR TAINING THF_ ��EET �O - �F/SP SDUJC SCREUJ COMMON WIRE NAILS m 12'oc "MINLgP�RpLq PLATE SPLICE. 425 IN NEICsHT.vATION WALLS OVERE3F-LOW ST OF RIGID PERFORATED 4EPVG PIPE DRANS AREGONSID 535 HIOA 1015 N1OA-2 � D SURROUNDED BY WASHED PEA -GRAVEL OR GRANULAR FILL WITH LE55 THAN 5% FINES. PLACE LGT3 - SD 52.5 (3)PL Y � LGT4-5D53 (4)PLY �2 (2) 2x6 LAMINATIONS Wi (v spl/I z 4 cF O (3) 16d NAILS STAGGERED 3300 A NONWOVEN -GEOTExTILE FILTER FABRIC BETWEEN THE DRAINAGE MATERIAL AND THE s (2 )VGTR/L (2)PL Y 3990 ROW OF STAGGERED 10d AT EACH sire of eorron 0 9 REMAINING WALL BACKFILL TO REDUCE SILT MIGRATION INTO THE DRAINAGE ZONE. PLACE - 6400 IGT - 2 (2)PLY COMMON WIRE NAILS a (o11 cc PLAiE SPLICE. 2 HGT-4Y 13250 Eacu si�E THE FILTER FABRIC SUCH THAT IT FULLY SEPARATES THE DRAINAGE MATERIAL AND THE 3 O3 (2) Ibd NAILS g 16' cc INTO 0. : 0j BACKFILL AND EXTENDS OVER THE TOP OF THE DRAINAGE ZONE. (3) 2x4 LAMINATIONS W/ (1)1 4. STUDS I' s 2-1/2'O THE LEVEL OF THE PERORATIONS IN THE PIPE ARE TO BE AT THE BOTTOM OF THE FOOTINGS �' � ROW OF STAGGERED 30d COMMON wiRE NaILS a i6•o 04 sinPsoN 36' C514 MAY BE 51MP50N LGT2 5IMP50N MGT W/ HDU AND THE DRAINS ARE TO BE CONSTRUCTED WITH SUFFICIENT GRADIENT TO ALLOW GRAVITY� EACH SIDE USED IN LIEU of NAILING A5 DISCHARGE AWAY FROM THE STRUCTURE. THE PERORATIONS ARE TO BE LOCATED ON THEt--- O (3) 2x6 LAMINATIONS W/ (2) w�icatE�.tNot sNow� FOR CLARITY) go LOWER PORTION OF THE PIPE. �q ,� ROWS OF STAGGERED 30d I -In' 2* COMMON WIRE NAILS 8'oc a RETAINING WALLS OR BASEMENTS WALLS ARE TO BE BACKFILLED WITH A MINIMUM 12 -INCH o EACH SIDE THICK WASHED GRAVEL BLANKET OR LINED WITH A [DRAINAGE MAT SUCH AS MIRA-DRAIN 6001 I-12' OR WELL GRADED AND DRAINING NATIVE SOILS OVER THE FULL HEIGHT OF THE WALLS NOTE: PLATE SPLICE (EXCLUDING THE FIRST I FOOT BELOW THE SURFACE). THIS DRAINAGE MATERIAL IS TO TIE INTO I APPLIES WHEN No OTHER ALLOWA15LE UPL IFT5 FASTENERS �F/SP SDUJC SCREUJ X65 HI 425 H2.5A 535 HIOA 1015 N1OA-2 930 LGT2 (2)PLY 1620 LGT3 - SD 52.5 (3)PL Y 2 505 LGT4-5D53 (4)PLY 2920 MCAT (2)PLY 3300 (1)VGTR/L (2)PL Y 1(000 (2 )VGTR/L (2)PL Y 3990 (1)VGT (2)PLY 3555 (2)VGT (2 )PLY 5110 (2 )VCT (3)PLY 6400 IGT - 2 (2)PLY 6 465 HGT - 3 (3 )PL's 9035 HGT-4Y 13250 -r-I On -r-I N N -r-I On N Ht: T UU I I NCS !J1'C/4 I N 5 T 5 I t: M. � �t-'� i c.t i � i Nv i c.,,y i �v. � �' I I I I w,aLUEs sasm as sir�soN STRONG ne FASTENER SCHEDULE. BUILDER TO FOLLOW ALL MANUFACTURER REQIIIREPENTS FOR FASTENER INSTALLATION. ROOF AND SURFACE RUNOFF ARSE N07 70 BE DISCHARGED INTO THE FOOTINGDRAIN 5Y5TEM J �JJ AND SHOULD BE HANDLED Bl' A SEPARATE RIGID TIGNtLINE DRAIN 5Y5TEM.SC SIMPSON vc�t DOUBLE INSTALLATION SIMPSON YGtR/L 7 pgZ�g 5.3.3� 23 19 u�� �2� �oua. U!/ HDU4 1525 J� CONCRETE WALL DRAINAGE D2 NAILING SCHEDULE AOR BUILT-UP COLUMN D2 PLATE 5FLICE D2 TRUSS UPLIFT CONNECTORS D2 Q W � O WALL FRAMING I► J y 28 �� 2 �O EXTEND STRAP ON PONY � _ . • • �' � OO WALL TO FLOOR ABOVE2 AUEF 3/4 �CFRU1N AN MT�O O O (D 1/2" MIN FROM CORNER TRUSS WITH ENERGY NOEL Q CENTER STRAP ON Q (IF PRESENT) 3 O ad 6 4'0.C. JOIStS AS SHOWN O o ° O OO SN�AR �3 3 �° O ll) *4 R�BAR MAY BE ooUALL NAILING PER FOUNDATION R�BAR ORTJI PARALLEL OR 7J1 EREA�SCtION PLAN I AMORE �� , o, o POSt TENSIONBLOCKING ON ° 4A4A �J 4A7/16' OSB OR SMART SIDE PROVIDE �CSI6 EACH JJ �I W Ln >ft PANEL BLOCKING lU/ ad � (�)acl 6 4' O.C. StAC�x�R SIDE OF SPLICE lU/8-16d o o O o o° � O 24" MIN MIN REBAR L�NCx7H 6' cc INTO DOUBLE TOP Li SIDES. NAIL tNROUC�I� TOP � a COMMON NAILS , o o , O PLATS 4 TOPCHORD BIRD O� FLANGE. DO NOT 5 0 0 0 °, BLOCK 1 TOE -NAIL �R,gpF a � . (4)TOP PLATE SPLICE LINE � o o , , (4) NOTE: NOLDOIUNS At i'�RSP�CTIV� INTERIOR PERSPECTIVE EXTERIOR 7J1 TYPICAL LADDER 5LOCKING � o 0 0 ° ° CORNER ARE SPACED (4) ROOF SHEATHING PER PLAN SHOWN lU/ tJl 4 2x O(a) lbd NAILS � � ° . � Q.aa�: �� O (2) 2X PLATE o o L0 I/2" FROM EDGE. UJ/ ad 6 6' cc INTO BIRD 2 - ' � a � o � � O ��. BLOCK BLOCKING. . • 2 . - ' � O 2X4 FLAT a 16" O.C. d .. ° ..... .. � a Q O O O NOLDOUJN fi'ER PLAN o 0 0 • -' � °. :. .� ° 2UlPONT WALL SHEATHING � � � � CLEAR SPAN 1�' MAXIMUM. _30 SIMPSON Nl CLIP. TYPICAL O �3) ad NAILS EACH SND � • � � � FOR TYPE RJ NOLDOIUN ° � � � � � � �°�� � �o SNE,4R NAILING TO MATCH •.. � � � � � ; �/ � 1 . � � — �D FOR NON RJ NOLDOIUNS X AT ALL TRUSS BOTTOM S `� a . a : a '� � UJA�� ABOVE � . ; , '" 2 BUILDING � p CHORD TO DOUBLE 70P O�LOOR JOIStS OR SOLID � .� � � .= � 3 fO PLA7� INt�RSEC710NS S � 5LOCKING .� a� . Q � �. a � S 6' MAXIMUM PONT' WALL �'- • � �. O O COMPRESSION 5LOCKING CODE 2018 IBC O A35 16' O.C. OPTION � . � � . . ..� OHDU NOLDOl1JN WIND SOFFIT MATERIAL � °.� `. �a, (WHEN SPECIFIED) O (2) ad NAILS a 8' O.G. OR (02 l IF PRESENT) o , ° � �� � � a � � ��sr � SCUD PUCK OR POSt PER � 16d � 16' O.C. EXP. B 131 MPH SEISMIC DESIGN II ':� S��,-TM � . $ . , � TN PLAN � BUILDER t0 DETERMINE CATEGORY D Cmva � . to 6 TALL STEP TO RETAIN STi-�D STi-�D�� IF StND OR StND/RJ IS ROOF SNOW 20 DIMENSIONAL lU/ SIMP50N A35 DIMENSIONAL TYPICAL 24 �,�„� 48' SOIL MAX APPROPRIATE.TRU55 SECTION r28 rl 6 LOAD 25 PSS RAI&ELD HEEL TO 5HEAR WALL CONNECTION D2 INTERIOR 5HEAR WALL TO JOIST A50VE CONNECTION D2 STEP FOOTING 4 PONY WALL FRAMING D2 SIMPSON STIED D2 2J 25 21 1 � THE TRU55 DESIGNER'S GABLE SND BRAG ENG. P.E. JOIN N. 1 DETAIL TAKES PRECEDENCE. USE THISO DATE DETAIL IF THE TRUSS DESIC�NER DOES N07 2x6 MINIMUM 5LOCKING BETIUEEN TRUSSES OR 01.01.23�. O tRUSS PER PLAN O FOOTING SIZE ANDPROVIDE A C�ABL� SND BRAG DETAIL RAFtERS, NAIL ROOD REVIEW O ROOD TRUSSES PER PLAN RE5AR 5CHEDULE SHEATHING 70 BLOCKING ZACK C. � O 2x 5LOCKING� O SIMPSON DTC 6 16' O.0 PE R PL AN UJ/ ad 6 3' O.C. ANALYST WITH NO GAP, TRUSSES 2 2 (6) Imd NAILS JOE G. OInd 6 O.C. FOR 2x BLOGKINGBEAR ON TOP PLATE O SHEET tO POST OR STUDS o TOP PLATE. O 5 3 (s) >�d r�,aiLs O 2x6 DIAGONAL O ROOF SHEATHING PER PLAN OR (3) I/4"x4-1/2' SDS/ PSR PL�4N o 0 0 3 BRACING SPACED � i2" +� X � tiMBE�oK SCREWS FOOTING° O.C. ATTACHED U/ (3) WALL SHEATHING PER PLAN -� � 2 3 sa 6' O.C. FOR SHEATHED 2 3 14)2x� ��at a 2a�" O.C. SE PLACED 5ELOW 16d NAILS O WALL PANEL �' O 2x6 BLOCKINCx W/ THE CONTINUOUS � 2 O SIMPSON CxBC 6 OF 8 SHEETS (INSTALLED IN PAIi�S) � 2 TOE NAILS ON ONE SIDE 4 � O (6) lmd NAILS FOOTING, IF � PROJECT NUMBER I TOE NAIL ON OPPOSITE SIDE PER BLOCK ������R�D O DOUBLE TOP PLAN 230311 OF EACH RAFTER OR TRUSS O MAINTAIN 1/8' t0 1/2' 3 �--- O S�IEA7�1 SOFFIT WITH OSB Cx�4B BEtlUEEu LATERAL ,���� O GABLE SND TRU55 BRACE AND TOP PLATE p�f.� o � � 2x4 BOTTOM CHORD ��W w� R 3 MAX. 1-I/4" GAP '�P :110 iQ TRUSS BRACING 8' P 'tip O 5E7lUEEN TRUSS ° MINIMUM 6 48' O.C. ALONG � AND TOP PLATE WALL BELOIU. ATTACH t0 � II MAX—m-> EACH TRUSS 378 6 4 TRU55 IN LINA CONNECTION TRUSS OFFSET CONNECTION � W1 (2) 16d NAILS `' o,�.Fs-rE��'G��`� �J SS/ONALEN r29-' r25 ,� r2f 17 �COPYRIGHT�uir•��R�� INC. DIGITALLY SIGNED MR HEEL TRUSS WITH SOFFIT D2 5HEAR WALL TO PARALLEL TRUSS D2 WIDENED FOOTING (OPTION) D2 C�,48L� SND 8��4CE D2 ��,-���W'T�A,��$ CERTIFICATE. ,� 42) 38) 34) 30 C� O 3/�' t�PLYWOOD 1 1 1 SUBFLOOR O 3x MEMBER At ADJOINING O SHEAR WALL NAILING PER � / � / � / PANEL GE6 FOR 6W21 60ANDDSUJ4 SHEAR WALLPLAN O O FLUSH DOUB�� 2x JOIST SECTION UJ/ 3X STUD SECTION W1 (2)2X SCUD SECTION W1 2X SCUD (SWI ONLY) �2 SUJ2 SHEAR WALL Sd NAIL: O OR MSR DOUBLE JOIST 4' EDGE - 12' FIELD . A­IIIIIIIIIIIIIIII IIIWITH IU B STIFFENERS OR � rJ SO SHEAR WALL Sd NAIL: O BEAM PER PLAN FLOOR JOIST PER PLAN � 3' EDGE - 12' FIELD 5W4 SHEAR WALL SD NAIL: O STUD/POST PER SHEAR (601 2' EDGE - 12'FIELD 0 0 \� WALL SCHEDULE O M5tC4853 (UJNEN � Ox/16' OSB SHEATHING � EAR O FOR �(FIELD) SPECIFIED ON PLAN) 3 M 3 LUALLS D PA �LEfR (01 l2JC614 OPTION (36' MIN LENGTH, WRAP O SHEAR WALL PER PLAN AROUND BEAM) (2) 2X MAY $E USED IN OS IS' MIN 70 STUD WALL OF 3X PER SHEAR (o � (C614 OPTION) WALL NOTES WALL O NAIL SHEATHINGTO BEAM. 6W1 SHEAR PANEL AOR COMPARISON DO NOT BREAK 5lU21 5lU31 OR 5lU4 SHEATHING SHEAR PANEL r42�IIIIIIIIIIIIIIIIII,38 r3f r3 0 I\D3 D3 SHEAR WALL AT E3EAM D3 5W2, 5W3, 5W4 5HEAR WALL NAILING D3 43 39 35 31 O SHEATH ROOF UNDER 0VERFRAMINCs O 2x FLOOR JOIST OR MFR. ....................... . . 2 O MANUFACTUREDJOISt. SPACING 4 SIZE PER O OVERFRAMINCx TRUSSES PLAN O l3) TOS NAILS EACH � O O ROOF SHEATHING PER PLAN - - 111 SIDE EVERY 16' ON CENTER ---- ------- � O VENTILATION ACCESS PER • • _ ' 2x BLOCKING CENTERED ON � 02 � 0 $UILDER 22-I/2 "x48" MAX DIMENSION. DOUBLE TOP PLATE. BULL DEPTH 1 O VTCB CLIPS w/ SD CONNECTOR 3 2 � O SIMPSON A35 REQUIRED FOR SlU2 4 SlU3 SHEAR PERSPECTIVE PERSPECTIVE 48"ON CENTER EACH WAY �j WALLS. (2) SIMfi'SON A35 At O 5lU4 e 5UJ5 SHEAR WALLS (StACxCxER At EACH SIDS �3 ",2 OF BLOCKING) � O INTERIOR SHEAR WALL NAILING 4 SHEATHING PER SECTION VIEW OVERALL PERSPECTIVE PLAN. � SIDE VIEW EXAMPLE OVERFRAMINCx 43 39 35 31 D3 D3 INTERIOR 5HEARWALL TO PERPENDICULAR JOISTS A50VE D3 OVERFIRAMING D3) 44 40 36 , 32 CONCRETE STEM WALL PER (:D PLAN �✓ O O DOUBLE TOP PLATE o � O SIMPSON HDU2 OR NDU5 O 2x6 BLOCKING t0 MATCH HOLDOUJN PER PLAN 2 STUD DEPTH O 04 REBAR FOR TOP 3 OlU L6TAI5 STRAP AT WINDOW � \ p REINFORCEMENT CORNERS, UN.O. O SIMPSON 555/Sx24 ANCHOR 2 O KING STUD(S) O HEADER PER PLAN OO � I OO SIMPSON 66t516 OPTION FOR NDU2 APPLICATIONS � O MUDSILL UJ/ ANCHOR BOLTS O SHEATH ALL StUDBPER � °.� \ PLAN INCLUDING PONY AND � a � (o CRIPPLE SCUDS a . ° aa.� . � O DOUBLE SCUD lU/ 16d 's 16" o _ T.i �O O.C. OR (2)5d 6 8' O.C. 4. "a4 � NO RIM REQUIRED WHEN a SLAB ON GRADE 44 40 36 1 32 D3 D3 AFA FORCE TRANFEIR AROUND OPENINGS D3 HLDU2 4 HDU5 CONNECTION D3 45 41 37 33O SHEAR WALL NAILING PER �. / � PLAN O SILL NAILING TO RIM :.::....s ..... <...., .,. .:... ,.:... GYPSUM WALL BOARD O � � 1 16d a 4' O.C. INSTALLED lU/5d COOLER NAILS 8' O.C. OR TYPE STRAP WHEN SPECIFIED S/UJ SCREWS 6 16' O.C. O DOU5LE I :41 2 O 16d NAIL 'a12' O.C. (UNO.) �4udmm0000GREATER RED FOR SLU2 OR REQUIRED SNEARUJALLS Sd NAIL 's12'O.C. ON ALL FRAMINGMEMBEi�S NOT AT IO O ATTACH FULL DEPTH BLOCKING TO DOUBLE 70P PANEL EDGES (UN.0) PLATE UJ/ (2) Ind a EACH BAY ORIENTATION OF CORNER STUD MAY VARY 3 1 2 � (Do � O FLOOR JOISt PER PLAN O NAIL SUBFLOOR t0 a: O Sd NAIL 6 6" O.C. ALL g BLOCKING lU/ Sd 'm 6' oc ; FRAMING MEMBERS A7 (UN.0) INSIDE CORNER 2"oON PANEL EDGES 4 12' O.C. ALL FRAMINC� MEMBERSPLAN O SCUD WALL OR BEAM PER NOT At PANEL EDGES O 1/16' OSB SHEATHING TO O S UNDERSIDE OF FLOOR O Sd L. TALL JOISTS 00 o PANEL EDCxESXUN.0) (to SDUJC EACH SCUD t0 DBL � 4 COP PLACE. SDIUC FLOOR O j j Dtt2Z At CANTILEVERED JOISt t0 DBL COP PLAtEBEAM. (4 SDWC 45 41 � OUTSIDE CORNER DETAIL 37 WALL ANDS WHEN SPECIFIED (UN.O.) TOTAL) lUl-ISN NOLDOUJN SPECIFIED 33�I D3 D3 IN51DE/CUT51DE CORNER D3 CANTILEVERED SHEAR WALL D3) 00 z 0 W w L h�c 'c')0 wI rte+ Q 'N W U � � U 'N L O y--' � (6 ca •L � a) O O cLU �o W�c�QLUo i6 J L i L c O� C : U �;�� a >W�ooZ 0 W. f6 a) N V O'� O V C 0 0 N N Q Q c a 0 f6 ~ O a) U L L U c� c o 0 c o N L c E E c .� 0 .5 O a >, O OQ cn 0 q--N�0 Q :3c 0) cn a a> Q U U '§ U N >, O 111- 2 N c 'c N cn(0-0U a -0� BUILDING CODE 2018 IAC WIND EXP. 5 91 MPH SEISMIC DESIGN CATEGORY D ROOF SNOW LOAD 25 P5F ENG. P.E. JOIN N. DATE 01.01.23 REVIEW ZACK C. ANALYST JOE G. SHEET 7 OF 8 SHEETS PROJECT NUMBER 230311 COPYRIGHT cQ2023 I-IODCxE ENGINEERING, INC. DIGITALLY SIGNED PER Ub4G 196-23-010 WITH A GLOBAL SIGN CERTIFICATE. TI$ CERTIFICATE MAY BE REhIOVID BY T44E JURISDICTION 1. GENERAL STRUCTURAL NOTES ALL LATERAL LOAD RESISTING AND GRAVITY LOAD RESISTING (IF SPECIFIED) STRUCTURAL MEMBERS ARE SHOWN ON THE ENGINEERING SHEETS AND DETAIL PAGES. THE ENCLOSED ENGINEERING CALCULATIONS DOCUMENT THE ANALYSIS USED TO DETERMINE THE STRUCTURAL MEMBERS OF THE ENGINEERING SHEETS. THE ENGINEERING CALCULATIONS ARE NOT REQUIRED TO BE REFERENCED FOR CONSTRUCTION AND ARE NOT REQUIRED BY ENGINEERING TO BE ONSITE. THIS ENGINEERING HAS BEEN CALCULATED TO RESIST CODE SPECIFIED VERTICAL AND LATERAL (WIND & SEISMIC) FORCES AFTER THE COMPLETION OF ALL STRUCTURAL ELEMENTS. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ENSURE STRUCTURAL STABILITY DURING CONSTRUCTION INCLUDING JOB SITE SAFETY; ERECTION METHODS; TEMPORARY SHORING, FORMWORK AND BRACING; USE OF EQUIPMENT AND CONSTRUCTION PROCEDURES. ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, ENGINEERING, AND/OR THE SITE CONDITIONS MUST BE REPORTED TO THE ARCHITECT AND ENGINEER WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL DIMENSIONS PRIOR TO CONSTRUCTION. STRUCTURAL DRAWINGS GOVERN. IF THERE ARE CONFLICTS WITH ARCHITECTURAL DRAWINGS, CONTACT HODGE ENGINEERING IMMEDIATELY. CONSTRUCTION OBSERVATION BY THE STRUCTURAL ENGINEER IS NOT PROVIDED. THIS ENGINEERING IS NOT INTENDED I N ANY WAY TO REVIEW OR APPROVE THE CONTRACTOR'S CONSTRUCTION PROCEDURES. STANDARDS ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 2018 INTERNATIONAL BUILDING CODE (IBC) AS AMENDED AND ADOPTED BY THE LOCAL BUILDING OFFICIAL OR APPLICABLE JURISDICTION. THIS ENGINEERING IS TO THE 2018 INTERNATIONAL BUILDING CODE (IBC) 2. DESIGN CRITERIA VERTICAL LOADS IBC TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS USE LIVE LOAD ATTICS WITH STORAGE (UNINHABITABLE) 20 PSF ATTICS WITHOUT STORAGE (UNINHABITABLE) 10 PSF DECKS 60 PSF EXTERIOR BALCONIES 60 PSF FIRE ESCAPES 40 PSF GUARDRAILS AND HAND RAILS 200 POUNDS GUARD RAIL INFILL COMPONENTS 50 POUNDS PASSENGER VEHICLE GARAGES 40 PSF ROOMS OTHER THAN SLEEPING ROOMS 40 PSF SLEEPING ROOMS 30 PSF STAIRS 40 PSF LATERAL FORCES ASCE 7-16 DIRECTIONAL PROCEDURE FOR BUILDINGS OF ALL HEIGHTS SEISMIC -- SEISMIC IMPORTANCE FACTOR PER ASCE 7-16, Ie = 1.00 BUILDING OCCUPANCY RISK CATEGORY PER ASCE 7-16 TABLE 1.5-1= II SOIL SITE CLASS PER ASCE 7-16 TABLE 20.3-1= PER PLAN SEISMIC DESIGN CATEGORY IBC TABLE 1613.2.5(1) & 1613.2.5(2) = PER PLAN ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE ANALYSIS RESPONSE MODIFICATION FACTOR R = 6.5 M411191" HODGE ENGINEERING IS NOT A GEOTECHNICAL ENGINEERING FIRM AND CANNOT MAKE A DETERMINATION OF SITE ADEQUACY FOR CONSTRUCTION. IF SITE SOIL BEARING CAPACITY OR SITE SLOPE IS IN DOUBT OR MAY AFFECT CONSTRUCTION THE BUILDER MUST CONTRACT A GEOTECHNICAL ENGINEERING FIRM FOR A SOILS REPORT. PROVIDE HODGE ENGINEERING WITH ANY GEOTECHNICAL INFORMATION PRIOR TO SITE PREPARATION. IF OWNER AND BUILDER THROUGH THEIR FEASIBILITY STUDIES DETERMINES THAT A GEOTECHNICAL REPORT IS NOT NEEDED THE FOLLOWING SOIL PARAMETERS AND METHODS ARE ASSUMED AND ACCEPTED BY THE OWNER AND BUILDER: SOIL BEARING PRESSURE: 1500 PSF (ASSUMED)* ACTIVE PRESSURE -UNRESTRAINED: 35 PCF (ASSUMED) PASSIVE RESISTANCE: 200 PCF (ASSUMED) COEFFICIENT OF FRICTION:.35 (ASSUMED) *1/3 INCREASE ALLOWED FOR SEISMIC OR WIND LOADING ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR COMPACTED STRUCTURAL FILL FOLLOWING SPECIFICATIONS NOTED BELOW. AREAS OVER -EXCAVATED SHALL BE BACKFILLED WITH LEAN CONCRETE (Fc=2000 PSI) OR COMPACTED STRUCTURAL BACKFILL. "STRUCTURAL BACKFILL" SHALL BE FILLED WITH APPROVED WELL -GRADED MATERIAL. MAXIMUM SIZE OF ROCK 4". ORGANIC MATERIAL AND DELETERIOUS MATTER NOT ALLOWED. COMPACT TO AT LEAST 95% OF IT'S MAXIMUM DENSITY AS DETERMINED BY ASTM D-1557. WHERE REQUIRED BY THE BUILDING OFFICIAL, THE CLASSIFICATION AND INVESTIGATION OF THE SOIL SHALL BE MADE BY A REGISTERED DESIGN PROFESSIONAL (IBC 1803.1). UNLESS A SOILS INVESTIGATION IS PROVIDED FOUNDATION DESIGN IS BASED ON AN ASSUMED AVERAGE SOIL BEARING OF 1500 PSF. ORGANIC SILT, ORGANIC CLAYS, PEAT OR UNPREPARED FILL SHALL NOT BE ASSUMED TO HAVE A BEARING CAPACITY. WHERE THE SOIL PROPERTIES ARE NOT KNOWN INSUFFICIENT DETAIL TO DETERMINE THE SITE CLASS, THIS ENGINEERING IS BASED ON 'DEFAULT' SITE CLASS D SOILS UNLESS THE BUILDING OFFICIAL OR GEOTECHNICAL DATA DETERMINES THAT SITE CLASS E OR F SOILS ARE PRESENT AT THE SITE IN ACCORDANCE WITH IBC TABLE 1613.2.5(1) & 1613.2.5(2). (UNLESS NOTED OTHERWISE) SITE GRADING: THE GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL BE SLOPED AWAY FROM THE BUILDING PER IBC 1804.4. EXPANSIVE SOILS SHALL BE REMOVED. FREE DRAINING BACKFILL MATERIAL FOR RETAINING AND BASEMENT WALLS CLEAN, FREE DRAINING, WELL GRADED SAND OR GRAVEL MATERIAL WHOSE MAXIMUM PARTICLE SIZE DOES NOT EXCEED 3/4" AND WHOSE FINES CONTENT (MATERIAL PASSING THE NO. 200 SIEVE) DOES NOT EXCEED 5%, WITH A MAXIMUM DUST RATIO %PASSING U.S. N0.200 SIEVE = 2/3 MAX. PASSING U.S. N0.400 SIEVE 4, CONCRETE CONCRETE WALLS EXCEEDING 8' IN HEIGHT MUST BE DESIGNED AND STAMPED BY A LICENSED PROFESSIONAL ENGINEER. IF CONCRETE WALLS OVER 8' HAVE BEEN DESIGNED FOR THIS PROJECT THEY WILL BE SPECIFIED ON THE PLAN AND SHOWN IN THE DETAILS. WOOD SHALL NOT BE USED TO SUPPORT MASONRY UNLESS SPECIFICALLY NOTED OTHERWISE ON THE S -SHEETS (IBC 2304.12). ALL BASEMENT WALLS BELOW FINISHED GRADE SHALL BE WATER PROOFED OUTSIDE BY APPROVED METHODS AND MATERIALS. CONCRETE: SHALL BE MADE WITH PORTLAND CEMENT ASTM C-150 TYPE II OR TYPE I AND SHALL BE READY MIXED PER ASTM C-94. MIX DESIGNS: THE CONTRACTOR SHALL DESIGN CONCRETE MIXES THAT MEET OR EXCEED THE REQUIREMENTS OF THE CONCRETE MIX TABLE FOR THE BEARING STRENGTH SPECIFIED. THE MIX DESIGNS SHALL FACILITATE ANTICIPATED PLACEMENT METHODS, WEATHER, TEMPERATURE, REBAR CONGESTION, AND ALL OTHER FACTORS REQUIRED TO PROVIDE A STRUCTURALLY SOUND AND ACCEPTABLE FINISHED PRODUCT. WATER REDUCING ADMIXTURES MAY BE USED TO MEET THESE REQUIREMENTS. MAXIMUM SLUMP SHALL BE 5". ADMIXTURES: ADMIXTURES SHALL BE BY MASTER BUILDERS, W.R. GRACE, OR PRE -APPROVED EQUAL. ALL MANUFACTURER'S RECOMMENDATIONS SHALL BE FOLLOWED. WATER: SHALL BE CLEAN AND POTABLE PROVIDE 3000 PSI @ 28 DAYS MINIMUM FOR DURABILITY AT BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS, PORCHES, CARPORT SLABS AND STEPS EXPOSED TO THE WEATHER AND FOR ALL GARAGE FLOOR SLABS. CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL BE NO LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT. NO SPECIAL INSPECTION FOR 3000 PSI CONCRETE - DURABILITY ONLY. REINFORCING STEEL: SHALL CONFORM TO ASTM A-615, GRADE 60. PLACE PER ACI 315 AND ACI 318. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE THE LONGEST LENGTHS PRACTICAL. WHERE SPLICES ARE NECESSARY THE LENGTH OF LAP SPLICE SHALL BE A MINIMUM OF 30 INCHES FOR #47 38 INCHES FOR #5, AND 45 INCHES FOR #6. THE MAXIMUM GAP BETWEEN NON -CONTACT PARALLEL BARS AT A LAP SPLICE SHALL NOT EXCEED 5 INCHES. CRACKS: UN -REINFORCED CONCRETE WILL CRACK. SLAB CRACK CONTROL IS RECOMMENDED IF CRACKS ARE UNDESIRABLE AND IS AS DIRECTED BY THE OWNER. OWNER IS TO DETERMINE THE ACCEPTABLE AMOUNT OF SLAB CRACKING PRIOR TO CONSTRUCTION AND REQUEST APPROPRIATE CRACK CONTROL. CONCRETE MINIMUM COVER OVER REINFORCEMENT CONCRETE CAST AGAINST EARTH = 3" EXPOSED TO WEATHER OR EARTH = 2" WALLS AND SLABS NOT EXPOSED TO WEATHER = 3/4" BOLTS MACHINE BOLTS (M.B.): ASTM A-307, GRADE A ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 36, CLASS 2A 5. CARPENTRY NAILS: CONNECTION DESIGNS ARE BASED ON "COMMON WIRE" NAILS WITH THE FOLLOWING PROPERTIES: PENNYWEIGHT DIAMETER (IN.) LENGTH (IN.) 8d MAX. 2-1/2 MIN. ITEM DESIGN f'c (PSI) MAX. W/C MIN. (2) AGGREGATE NOTES CEMENTITOUS 4 BOISE CASCADE RATIO FLYASH (PCY) SIZE (IN) AND WEB FILLER (1) MATERIAL 2x GANGLAM GALV (G185) MASONRY WALLS (4) CEILING JOIST NOT ATTACHED TO Fb=1700 PSI (SACKS/YARD) FOUNDATIONS 2500 @ 28 DAYS 0.45 - - 3/4 - - 5-1/2 STEMWALLS 3000 @ 28 DAYS 0.45 100 3/4 - - 5-1/2 SLAB ON GRADE 3000 @ 28 DAYS 0.45 100 3/4 END NAIL 5-1/2 CONCRETE FRAME 2500 @ 28 DAYS 0.45 100 3/4 - - 5-1/2 PROVIDE 3000 PSI @ 28 DAYS MINIMUM FOR DURABILITY AT BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS, PORCHES, CARPORT SLABS AND STEPS EXPOSED TO THE WEATHER AND FOR ALL GARAGE FLOOR SLABS. CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL BE NO LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT. NO SPECIAL INSPECTION FOR 3000 PSI CONCRETE - DURABILITY ONLY. REINFORCING STEEL: SHALL CONFORM TO ASTM A-615, GRADE 60. PLACE PER ACI 315 AND ACI 318. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE THE LONGEST LENGTHS PRACTICAL. WHERE SPLICES ARE NECESSARY THE LENGTH OF LAP SPLICE SHALL BE A MINIMUM OF 30 INCHES FOR #47 38 INCHES FOR #5, AND 45 INCHES FOR #6. THE MAXIMUM GAP BETWEEN NON -CONTACT PARALLEL BARS AT A LAP SPLICE SHALL NOT EXCEED 5 INCHES. CRACKS: UN -REINFORCED CONCRETE WILL CRACK. SLAB CRACK CONTROL IS RECOMMENDED IF CRACKS ARE UNDESIRABLE AND IS AS DIRECTED BY THE OWNER. OWNER IS TO DETERMINE THE ACCEPTABLE AMOUNT OF SLAB CRACKING PRIOR TO CONSTRUCTION AND REQUEST APPROPRIATE CRACK CONTROL. CONCRETE MINIMUM COVER OVER REINFORCEMENT CONCRETE CAST AGAINST EARTH = 3" EXPOSED TO WEATHER OR EARTH = 2" WALLS AND SLABS NOT EXPOSED TO WEATHER = 3/4" BOLTS MACHINE BOLTS (M.B.): ASTM A-307, GRADE A ANCHOR BOLTS (A.B.): ASTM F1554, GRADE 36, CLASS 2A 5. CARPENTRY NAILS: CONNECTION DESIGNS ARE BASED ON "COMMON WIRE" NAILS WITH THE FOLLOWING PROPERTIES: PENNYWEIGHT DIAMETER (IN.) LENGTH (IN.) 8d 0.131 2-1/2 10d 0.148 3 16d 0.162 3-1/2 20d 0.192 4 WOOD SHEATHING (STRUCTURAL): SHEATHING SHALL BE PLYWOOD (CDX) OR ORIENTED STRAND BOARD (OSB). PLYWOOD SHEATHING SHALL BE 5 -PLY MINIMUM WHERE INDICATED AS 3/4" OR THICKER. WOOD SHEATHING SHALL BE "RATED SHEATHING" CONFORMING TO PSI -95 AND/OR PS2-92. ALL PANELS SHALL BEAR THE STAMP OF AN APPROVED GRADING AGENCY. SPAN RATING SHALL BE PROVIDED AS FOLLOWS: ROOF (24/16); WALLS (24/16); FLOORS (2011 O.C.) UNLESS NOTED OTHERWISE. ALL WOOD SHEATHED WALLS SHALL BE BLOCKED AT ALL PANEL EDGES UNLESS NOTED OTHERWISE. GLUE -LAMINATED MEMBERS: PER ANSI/RITC A190.1. MEMBERS SHALL BE COMBINATION 24F -V4 DOUGLAS FIR FOR SIMPLE SPANS AND 24F -V8 DOUGLAS FIR FOR CANTILEVERED SPANS AND TRUSS CHORDS (FB=2400 PSI, FV=240 PSI, E=1.8X10^6 PSI) AND DOUGLAS FIR COMBINATION 3 FOR COLUMNS AND TRUSS WEB MEMBERS, ALL WITH EXTERIOR GLUE. ALL MEMBERS TO HAVE AITC OR APA-EWS STAMP. FRAMING LUMBER: EACH PIECE SHALL BEAR THE GRADE TRADEMARK OF THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB), WESTERN WOOD PRODUCTS ASSOCIATION (WWPA), OR OTHER AGENCY ACCREDITED BE THE AMERICAN LUMBER STANDARD COMMITTEE (ALSC) TO GRADE UNDER ALSC CERTIFIED GRADING RULES. SPECIES AND GRADE (BASE DESIGN VALUE) (U.N.O.) 1. 2X TO 4X JOISTS, PURLINS AND HEADERS. "DOUG FIR -LARCH" NO. 2 (Fb=900 PSI, Fv=180 PSI) OR "HEM -FIR" NO. 1 (Fb=975 PSI, Fv=150 PSI) 2. 6X POSTS AND COLUMNS. "DOUG FIR -LARCH" NO. 1(Fc=1000 PSI) 3. EXTERIOR STUDS, INTERIOR BEARING WALLS "HEM -FIR" NO. 2 4. INTERIOR NON-BEARING STUD WALLS. "HEM -FIR" NO. 2 STUD GRADE 5. 2X & 3X T&G DECKING: "DOUG FIR -LARCH" COMMERCIAL (Fb=1650 PSI, E=1700 KSI) COLUMNS: ALL COLUMNS NOT SPECIFIED OR OTHERWISE NOTED ON THE PLAN ARE TO BE TWO STUDS. MULTIPLE STUDS ARE TO BE SPIKE LAMINATED TOGETHER WITH (2)16d NAILING AT 6" ON CENTER STAGGERED (U.N.O.). ALL COLUMNS SUPPORTING GIRDER TRUSSES OR GLUE LAMINATED BEAMS ARE TO BE THREE STUDS. ALL BEARING WALLS OVER 10' SHALL BE LATERALLY BRACED AT 4' O.C. CONTRACTOR SHALL VERIFY ALL POINT LOADS ARE SUPPORTED TO THE FOUNDATION. FLOORING AND ROOFING: PLYWOOD SUBFLOORING SHALL BE 4" T&G CDX GLUED AND NAILED. NAILING SHALL BE 8d @ 6" O.C. ALONG PANEL EDGES, AND 12" O.C. IN FIELD. STAGGER END LAPS. ROOF SHEATHING SHALL BE 2" CDX OR 16" OSB NAILED WITH 8d @ 6" O.C. ALONG PANEL EDGES AND 12" O.C. IN THE FIELD. STAGGER END LAPS. FRAMING LUMBER (MANUFACTURED): SHALL BE MANUFACTURED BY THE FOLLOWING MANUFACTURERS IN ACCORDANCE WITH APPROVED SHOP AND INSTALLATION DRAWINGS. APPROVED MANUFACTURERS ITEM PRESERVATIVE CONNECTORS & APPLICATION SPECIFIED MATERIAL TREATMENT (1) SPECIFIED FOUNDATION SILL LOUISIANA ROSEBURG FOREST GEORGIA MEMBER TRUS-JOIST BOISE CASCADE PACIFIC PRODUCTS PACIFIC AND WEB FILLER 2x TIMBERSTRAND 2x GANGLAM GALV (G185) MASONRY WALLS (4) CEILING JOIST NOT ATTACHED TO Fb=1700 PSI (3)16d Fb=2250 PSI 2X, & 4X (FIR) ACQ, CBA, CA 2x SCL FRAMING, DECKING, PARALLEL RAFTER (HEEL JOINT) FACE NAIL 2X, & 4X (CEDAR) NONE E=1300 KSI POSTS & LEDGERS E=1500 KSI 6X OR GLULAM (FIR) ACQ, CBA, CA GALV (G185) Fv=400 PSI 6X OR GLULAM Fv=275 PSI END NAIL (2)16d (CEDAR) 1-3/4" PARALLAM 1-3/4" VERSALAM 1-3/4" LP LVL 1-3/4" RIGID -LAM 1-3/4" G -P -LAM 1-3/4" SCL Fb=2900 PSI Fb=2800 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI (NOT AT BRACED WALL PANELS) E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI AT INTERSECTING WALL CORNERS Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI (2" TO 2" HEADER) 3-1/2" PARALLAM 3-1/2" VERSALAM 3-1/2" LP LVL 3-1/2" RIGID -LAM 2 -PLY G -P -LAM* 3-1/2" SCL Fb=2900 PSI Fb=3100 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI AT END JOINTS E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI BAND JOIST (NOT AT BRACED PANEL) Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI BAND JOIST AT BRACED PANEL 5-1/4" PARALLAM 5-1/4" VERSALAM 5-1/4" LP LVL 5-1/4" RIGID -LAM 3 -PLY G -P -LAM* 5-1/4" SCL Fb=2900 PSI Fb=3100 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI TOP PLATES, LAPS AT CORNERS AND E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI JOIST TO STILL, TOP PLATE OR Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI RIM JOIST/BAND JOIST OR BLOCKING 7" PARALLAM 7" VERSALAM 7" LP LVL 7" RIGID -LAM 4 -PLY G -P -LAM* 2" SUBFLOOR TO JOIST OR GIRDER Fb=2900 PSI Fb=3100 PSI Fb=2950 PSI Fb=2900 PSI Fb=3100 PSI 7" SCL E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI E=2000 KSI 2 LUMBER LAYERS Fv=290 PSI Fv=285 PSI Fv=290 PSI Fv=285 PSI Fv=285 PSI RIM BOARD OR APA / EWS PERFORMANCE RATED RIM (PRR-401) 1-1/8" MINIMUM THICKNESS RIM JOIST JOIST TO BAND/RIM JOIST * - CONNECT MULTI -PLY MEMBERS PER MANUFACTURER'S RECOMMENDATIONS - LSL's MAY BE USED IN PLACE OF LVL's WHEN SPECIFIED - PRESERVATIVE TREATED WOOD REQUIREMENTS: IBC 2304.12: WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WITHOUT JOISTS SHALL NOT BE CLOSER THAN 18 INCHES, OR WOOD GIRDERS CLOSER THAN 12 INCHES TO THE EXPOSED GROUND IN CRAWL SPACES. WOOD FRAMING MEMBERS, INCLUDING WOOD SHEATHING, WHICH REST ON EXTERIOR FOUNDATION WALLS SHALL NOT BE LESS THAN 8 INCHES FROM EXPOSED EARTH. SILLS IN CONTACT WITH CONCRETE SHALL BE PRESERVATIVE -TREATED WOOD. CLEARANCE BETWEEN WOOD SIDING AND EARTH SHALL NOT BE LESS THAN 6 INCHES. POSTS SHALL BE PRESERVATIVE -TREATED UNLESS SUPPORTED BY A PEDESTAL GREATER THAN 8 INCHES FROM EXPOSED GROUND. w 0 W PRESERVATIVE TREATED WOOD FASTENER REQUIREMENTS: ALL METAL CONNECTORS LESS THAN 1/2" DIAMETER (R317.3.1) COMING IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE SIMPSON Z -MAX, TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED. CCA: CHROMATED COPPER ARSENATE NOT PERMITTED. SBX: DOT SODIUM BORATE ACQ: ALKALINE COPPER QUAT CBA AND CA: COPPER AZOLE G607 G90, AND G185 PER ASTM A23 FOR CONNECTORS, AND ASTM A153 FOR FASTENERS. MECHANICALLY GALVANIZED FASTENERS PER ASTM B695, CLASS 55 OR GREATER. GENERAL CARPENTRY NOTES: STAGGER ALL NAILING TO PREVENT SPLITTING OF WOOD MEMBERS. PRESSURE -TREAT ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY. HOLES AND CUTS IN PLATES SHOULD BE TREATED WITH A 20% SOLUTION OF COPPER NAPHTHENATE. BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. PROVIDE CUT WASHERS WHERE BOLT HEADS, NUTS AND LAG SCREW HEADS BEAR ON WOOD. PROVIDE A MINIMUM 3x3x.229 PLATE WASHER ON ALL ANCHOR BOLTS WHICH CONNECT MUD SILLS TO FOUNDATION. DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS TABLE FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. GOOD FRAMING PRACTICE TO USE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND MORE THAN 2 THE LENGTH AND AROUND OPENINGS UNLESS DESIGNED BY A FLOOR JOIST MANUFACTURER. POSITIVE CONNECTIONS SHALL BE PROVIDED AT POST -BEAM CONNECTIONS TO ENSURE AGAINST UPLIFT AND LATERAL DISPLACEMENT. USE 12" CS -14 UNLESS NOTED OTHERWISE. METAL -PLATE -CONNECTED WOOD TRUSSES: SHALL SPECIAL INSPECTIONS OF WOOD TRUSSES WITH OVERALL HEIGHTS OF 60 INCHES OR GREATER SHALL BE PERFORMED TO VERIFY THAT THE INSTALLATION OF THE PERMANENT INDIVIDUAL TRUSS MEMBER RESTRAINT/BRACING HAS BEEN INSTALLED IN ACCORDANCE WITH THE APPROVED TRUSS SUBMITTAL PACKAGE. FOR WOOD TRUSSES WITH A CLEAR SPAN OF 60 FEET OR GREATER, THE SPECIAL INSPECTOR SHALL VERIFY DURING CONSTRUCTION THAT THE TEMPORARY INSTALLATION RESTRAINT/BRACING IS INSTALLED IN ACCORDANCE WITH THE APPROVED TRUSS SUBMITTAL PACKAGE. FASTENING SCHEDULE FOR WOOD STRUCTURAL MEMBERS IBC 2304.10.1 ITEM PRESERVATIVE CONNECTORS & APPLICATION SPECIFIED MATERIAL TREATMENT (1) FASTENERS (2)(3) FOUNDATION SILL BLOCKING AT RAFTERS/TRUSS NOT TOENAIL, EACH END PLATES, TOP PLATES & 2X, 4X, 6X OR GLULAM SBX GALV (G60) LEDGERS ON (FIR) 16d @ 6" O.C. AND WEB FILLER CONCRETE OR ACQ, CBA, CA GALV (G185) MASONRY WALLS (4) CEILING JOIST NOT ATTACHED TO FACE NAIL (3)16d PARALLEL RAFTER, LAPS OVER PARTITION 2X, & 4X (FIR) ACQ, CBA, CA GALV (G185) FRAMING, DECKING, PARALLEL RAFTER (HEEL JOINT) FACE NAIL 2X, & 4X (CEDAR) NONE GALV (G90) POSTS & LEDGERS RAFTER OR ROOF TRUSS TO TOP 6X OR GLULAM (FIR) ACQ, CBA, CA GALV (G185) BEAMS AND COLUMNS 6X OR GLULAM RAFTERS TO RIDGE VALLEY/ HIP END NAIL (2)16d (CEDAR) NONE GALV (G90) PRESERVATIVE TREATED WOOD FASTENER REQUIREMENTS: ALL METAL CONNECTORS LESS THAN 1/2" DIAMETER (R317.3.1) COMING IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE SIMPSON Z -MAX, TRIPLE ZINC COATED, OR HOT DIPPED GALVANIZED. CCA: CHROMATED COPPER ARSENATE NOT PERMITTED. SBX: DOT SODIUM BORATE ACQ: ALKALINE COPPER QUAT CBA AND CA: COPPER AZOLE G607 G90, AND G185 PER ASTM A23 FOR CONNECTORS, AND ASTM A153 FOR FASTENERS. MECHANICALLY GALVANIZED FASTENERS PER ASTM B695, CLASS 55 OR GREATER. GENERAL CARPENTRY NOTES: STAGGER ALL NAILING TO PREVENT SPLITTING OF WOOD MEMBERS. PRESSURE -TREAT ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY. HOLES AND CUTS IN PLATES SHOULD BE TREATED WITH A 20% SOLUTION OF COPPER NAPHTHENATE. BOLT HOLES IN WOOD MEMBERS SHALL BE A MINIMUM OF 1/32" TO A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER. PROVIDE CUT WASHERS WHERE BOLT HEADS, NUTS AND LAG SCREW HEADS BEAR ON WOOD. PROVIDE A MINIMUM 3x3x.229 PLATE WASHER ON ALL ANCHOR BOLTS WHICH CONNECT MUD SILLS TO FOUNDATION. DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS. REFER TO PRESERVATIVE TREATED WOOD REQUIREMENTS TABLE FOR GALVANIZING REQUIREMENTS FOR CONNECTORS AND FASTENERS. GOOD FRAMING PRACTICE TO USE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND MORE THAN 2 THE LENGTH AND AROUND OPENINGS UNLESS DESIGNED BY A FLOOR JOIST MANUFACTURER. POSITIVE CONNECTIONS SHALL BE PROVIDED AT POST -BEAM CONNECTIONS TO ENSURE AGAINST UPLIFT AND LATERAL DISPLACEMENT. USE 12" CS -14 UNLESS NOTED OTHERWISE. METAL -PLATE -CONNECTED WOOD TRUSSES: SHALL SPECIAL INSPECTIONS OF WOOD TRUSSES WITH OVERALL HEIGHTS OF 60 INCHES OR GREATER SHALL BE PERFORMED TO VERIFY THAT THE INSTALLATION OF THE PERMANENT INDIVIDUAL TRUSS MEMBER RESTRAINT/BRACING HAS BEEN INSTALLED IN ACCORDANCE WITH THE APPROVED TRUSS SUBMITTAL PACKAGE. FOR WOOD TRUSSES WITH A CLEAR SPAN OF 60 FEET OR GREATER, THE SPECIAL INSPECTOR SHALL VERIFY DURING CONSTRUCTION THAT THE TEMPORARY INSTALLATION RESTRAINT/BRACING IS INSTALLED IN ACCORDANCE WITH THE APPROVED TRUSS SUBMITTAL PACKAGE. FASTENING SCHEDULE FOR WOOD STRUCTURAL MEMBERS IBC 2304.10.1 ITEM TYPE CONNECTION BLOCKING BETWEEN CEILING JOISTS, TOENAIL, EACH END (3) 8d RAFTERS/TRUSSES TO TOP PLATE BLOCKING AT RAFTERS/TRUSS NOT TOENAIL, EACH END (2) 8d AT WALL TOP PLATE/RAFTER/TRUSS FLAT BLOCKING TO TRUSS FACE NAIL 16d @ 6" O.C. AND WEB FILLER CEILING JOISTS TO TOP PLATE TOENAIL, EACH JOIST (3) 8d CEILING JOIST NOT ATTACHED TO FACE NAIL (3)16d PARALLEL RAFTER, LAPS OVER PARTITION CEILING JOIST ATTACHED TO PARALLEL RAFTER (HEEL JOINT) FACE NAIL PER TABLE 2308.7.3.1 COLLAR TIE TO RAFTER FACE NAIL (3)10d RAFTER OR ROOF TRUSS TO TOP TOENAIL (3)10d PLATE RAFTERS TO RIDGE VALLEY/ HIP END NAIL (2)16d RAFTERS, OR RAFTER TO 2" RIDGE RAFTERS TO RIDGE VALLEY/ HIP TOENAIL (3)10d RAFTERS, OR RAFTER TO 2" RIDGE STUD TO STUD (NOT AT BRACED WALL PANELS) FACE NAIL 16d @ 24" O.C. STUD TO STUD AND ABUTTING STUDS FACE NAIL 16d @ 16" O.C. AT INTERSECTING WALL CORNERS BUILT-UP HEADER FACE NAIL, EACH EDGE 16d @ 16" O.C. (2" TO 2" HEADER) CONTINUOUS HEADER TO STUD TOENAIL (4) 8d TOP PLATE TO TOP PLATE FACE NAIL 16d @ 16" O.C. TOP PLATE TO TOP PLATE, END JOINT, FACE NAIL (8)16d, EACH SIDE END JOINT, AT END JOINTS FACE NAIL (M IN 24" LAP SPLICE) BOTTOM PLATE TO JOIST/RIM JOIST/ BAND JOIST (NOT AT BRACED PANEL) FACE NAIL 16d @ 16" O.C. BOTTOM PLATE TO JOIST/RIM JOIST/ FACE NAIL (2) 16d @ 16" O.C. BAND JOIST AT BRACED PANEL STUD TO TOP OR BOTTOM PLATE TOENAIL (4) 8d STUD TO TOP OR BOTTOM PLATE END NAIL (2)16d TOP OR BOTTOM PLATE STUD END NAIL (2)16d TOP PLATES, LAPS AT CORNERS AND FACE NAIL (2)16d INTERSECTIONS JOIST TO STILL, TOP PLATE OR TOENAIL (3) 8d GIRDER RIM JOIST/BAND JOIST OR BLOCKING TO TOP PLATE/SILL/FRAMING BELOW TOENAIL 8d @ 6" O.C. 2" SUBFLOOR TO JOIST OR GIRDER FACE NAIL (2)16d 2" PLANKS FACE NAIL, EACH BEARING (2)16d (PLANK & BEAM - FLOOR & ROOF) BUILT-UP GIRDERS AND BEAMS FACE NAIL AT TOP AND BOTTOM 20d @ 32" O.C. 2 LUMBER LAYERS STAGGERED ON OPPOSITE SIDES LEDGER STRIP SUPPORTING JOISTS FACE NAIL, EACH JOIST OR RAFTER (3)16d OR RAFTERS JOIST TO BAND/RIM JOIST END NAIL (3)16d BRIDGING/BLOCKING TO TOENAIL, EACH END (2) 8d JOIST, RAFTER OR TRUSS CONNECTIONS ARE COMMON NAILS U.N.O LAG SCREWS: SHALL BE OF A DIAMETER INDICATED ON DRAWINGS WITH A MINIMUM OF 8x DIAMETER EMBEDMENT IN SUPPORTING MEMBER UNLESS NOTED OTHERWISE. CLEARANCE HOLE FOR THE SHANK SHALL BE THE SAME DIAMETER AS THE SHANK AND THE SAME DEPTH OF PENETRATION AS THE UNTHREADED PORTION OF THE SHANK. THE LEAD HOLE FOR THE THREADED PORTION SHALL HAVE A DIAMETER EQUAL TO 60 TO 75% OF THE SHANK DIAMETER AND A LENGTH EQUAL TO AT LEAST THE LENGTH OF THE THREADED PORTION. THE THREADED PORTION OF THE SCREW SHALL BE INSERTED IN ITS LEAD HOLE BY TURNING WITH A WRENCH, NOT BY DRIVING WITH A HAMMER. SOAP OR OTHER LUBRICANT SHALL BE USED ON THE SCREWS OR IN THE LEAD HOLE TO FACILITATE INSERTION AND TO PREVENT DAMAGE TO THE SCREW. METAL PLATE CONNECTED WOOD TRUSSES: SHALL BE MANUFACTURED BY AN APPROVED TRUSS MANUFACTURER IN ACCORDANCE WITH APPROVED SHOP AND INSTALLATION DRAWINGS. ALL ROOF TRUSSES ARE TO BE PRE-ENGINEERED BY OTHERS. ROOF TRUSSES SHALL BE PROVIDED TO COMPLETE THE ROOF FRAMING FROM THE SHEATHING TO THE SUPPORTING MEMBERS BELOW. SHOP DRAWINGS AND CALCULATIONS SHALL BE PRODUCED UNDER THE SUPERVISION OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE ADDRESSED ON THIS ENGINEERING. DETAIL DRAWINGS TO INDICATE ALL INFORMATION AS REQUIRED IN IBC 2303.4.1.1 INCLUDING PERMANENT LATERAL BRACING AND CONNECTION DETAILS. -JOISTS: SHALL BE APA EWS PERFORMANCE RATED I -JOISTS (PRI). I -JOISTS SHALL BE MANUFACTURED IN CONFORMANCE WITH APA PRI -400 CONFORMING TO APPROVED SHOP AND INSTALLATION DRAWINGS. L 0 _ Sao w 13Q �° ) vi v fii •L N .O O cLU �� LJ.I ��Q�>to i6 J L i L c 0 C c V �;�� a ;