Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Earsely_Investments_Yelm_Detail_Shop_2018_WSEC_project_summary
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2023 NEEA, All rights reserved Project & Applicant Information Project Title Earsley Investments - Yelm Detail Shop - 2018 WSEC For Building Department Use: I Date: Aug 31, 2023 Project Address 108 Yelm Ave W Yelm, WA 98597 Applicant Name Kyle Christensen Applicant Phone 253-552-2026 Applicant Email kyle@tcfarchitecture.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type(s) Services, General Building Cond. Floor Area 3,411 Project Scope New Building Space Conditioning Categories Fully Conditioned Project Cond. Floor Area 3,411 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Envelope Project Description New single story wood frame building (Type VB Construction) to be used as an auto detail shop. The building has a lobby/retail space, toilet room, 3 auto bays, parts storage area on the ground floor and additional storage in a small mezzanine area. Envelope Compliance Scope Scope Space Conditioning Category Compliance Method R,WR/SRR per Category UA Calculation Adjustment Fenestration Alternates Compliance Verification and Method New Building Fully Conditioned Prescriptive 6.49%/0"/` None selected No alternates selected COMPLIES Air Barrier Testing Air barrier testing included in project scope Air Barrier Comments Aug 31, 2023 Project Title Earsley Investments - Yelm Detail Shop - 2018 WSEC Date Aug 31, 2023 Scope & Space Conditioning NEW BUILDING - FULLY CONDITIONED Compliance Verification COMPLIES Window -to -wall Ratio 6.49% 1 Skylight -to -roof -ratio 0% Vertical Fenestration Alternate No alternates selected Opaque Envelope Assemblies Insulation R -Values Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) 2nd Layer (MB Roof) U -Factor Net Area (SF) Insulation entirely above deck A40.01 I ROOF TYPE A Exterior R-38 (< 0.04%) U-0.027 3,131 U -Factor Source: WSEC Appendix A U -Factor Source Description: Is this assembly exterior or interior?: Exterior Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U -Factor Net Area (SF) Wood -framed and other - A2.10, A30.01 Commercial 6W/MSI, 6W/MS2, 6W/MS3 Exterior R-21 R-0 (< 0.04%) U-0.054 4,470 Which insulation code target does wall comply with?: R-21 Cavity + Intermediate U -Factor Source: WSEC Appendix A Framing U -Factor Source Description: Table A103.3.1(5) Wall Framing Type (Standard, Inter., Advanced): Intermediate Framing Depth: 2x6 Framing Spacing: 16" o.c. Is this assembly exterior or interior?: Exterior Slab -on -grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F -Factor Perimeter Length (SF) Unheated slab A21.01 I FLOOR TYPE A At grade level R-10 I R-0 I I F-0.54 241 Slab Insulation Method: 2 ft vertical (from top of slab downward) F -Factor Source: WSEC Appendix A F -Factor Source Description: Table A106.1 Fenestration & Opaque Door Assemblies Insulation R -Values Opaque Doors Location in Documents Assembly ID Assembly Location Door Insulation U -Factor Rough Opening (SF) Swinging A2. 10a, A62.01, A63.101 106B Exterior R-2.6 I I U-0.36 21 What percentage of this opaque door is glazing?: 50% or less U -Factor Source: Other U -Factor Source U -Factor Source Description: Manufacturer Product Data Is this assembly exterior or interior?: Exterior Is this a public entrance door?: No Garage, Sectional A2.I Oa, A63.11 1 104A, 105A, 106A, 106C Exterior R-17.5 U-0.12 660 What percentage of this opaque door is glazing?: 50% or less U -Factor Source: Other U -Factor Source U -Factor Source Description: Manufacturer Product Data Is this assembly exterior or interior?: Exterior Vertical Fenestration Location in Documents Assembly ID Assembly Location Orientation Shading (PF) Fenestration SHGC Fenestration U -Factor Rough Opening (SF) Fixed - Class AW or site built A2.10, A62.01 I SB -1 Exterior North Facing I PF < 0.2 1 SHGC-0.33 U-0.355 32 U -Factor & SHGC Source: Other Source U -Factor Source Description: Kawneer Trifab VG 451T storefront data & Guardian Glass Product Data Is this assembly exterior or interior?: Exterior Fixed - Class AW or site built A2.10, A62.01 SB -2, SB -3, SB -46, SD -4, SC -5, SC- Exterior South/East/West Facing PF < 0.2 SHGC-0.33 U-0.355 302 U -Factor & SHGC Source: Other Source U -Factor Source Description: Kawneer Trifab VG 451T storefront data & Guardian Glass Product Data Is this assembly exterior or interior?: Exterior Glazed Doors Location in Documents Assembly ID Assembly Location Orientation Shading (PF) Fenestration SHGC Fenestration U -Factor Rough Opening (SF) Swinging entrance door A2.10,62.01 I IOTA Exterior North Facing I PF < 0.2 1 SHGC-0.198 U-0.535 24 U -Factor & SHGC Source: Other Source U -Factor Source Description: Kawneer 500T Insulpour Thermal Entrances product data & Guardian Glass SN -68 Product Data Is this assembly exterior or interior?: Exterior Is this a public entrance door?: Yes Door enclosed within a vestibule?: No vestibule