Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MECHANICAL COMPLIANCE SUMMARY
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2023 NEEA, All rights reserved Project & Applicant Information Project Title Earsley Investments - Yelm Detail Shop - 2018 WSEC For Building Department Use: I Date: Aug 31, 2023 Project Address 108 Yelm Ave W Yelm, WA 98597 Applicant Name Kyle Christensen Applicant Phone 253-552-2026 Applicant Email kyle@tcfarchitecture.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Services, General Building Cond. Floor Area 3,411 General Project Types New Building New Building or Addition Mechanical Scope Single Zone Systems &Equipment AlterationProject Mechanical Scope Cond. Floor Area 3,411 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Mechanical Project Description Scope and Method Scope & Space Condition in NEW BUILDING - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES Single Zone Air Systems Category - Heat pump, packaged (PTHP, SPVHP, room) Air Systems Summary Information Quantity System/Equip ID of Items Supply Airflow Control Economizer DOAS Ventilation Equipment ui Higher E Higqp Equipment Efficiency Mechanical Compliance Project Type Mechanical Scope Exception(s) Applied? Provided. Efficiency Option Applied? . Compliance Verification Scope and Method New Single Zone Systems & Y es No NA COMPLIES Load Efficiency Units Verification Building Equipment Single package, vertical 1 9,200 1 0 Additional Efficiency 12.4 EER Credits Included (AEC) HP -1 Heat pump, vertical (SPVHP), Single package, vertical heat I Does building include occupancy classifications requiring Yes Does project equipment? ro'ect include DOAS a ui ment? No DORS? COMPLIES Based on project scope do TSPR requirements apply? No Do all systems comply with Appendix D standard reference design or qualify for an exception to No TSPR. Scope & Space Condition in NEW BUILDING - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES Single Zone Air Systems Category - Heat pump, packaged (PTHP, SPVHP, room) Air Systems Summary Information Quantity System/Equip ID of Items Supply Airflow Control Ventilation Standard Ventilation CFM (Total if Multiple Items) Ventilation Air Source paired with DOAS Ventilation enerEnergy Recovery energy recovery Efficiency (/o) HP -1 I I Constant volume ASHRAE Standard 62.1 75 Integral PL Efficiency Compliance Equip ID Air Systems & Equipment - Cooling System/ Cooling System/Equip Type Specific Type Cooling Capacity AEC Efficiency Econo Exception Combined Efficiency Proposed Cooling CE Proposed Part PL Efficiency Compliance Equip ID Heating System/Equip Type Specific Type per item (Btu/h) Multiplier Multiplier (FL & PL) Multiplier (AEC & Econ o) Efficiency Units Load Efficiency Units Verification HP -1 Heat pump, vertical (SPVHP) Single package, vertical 1 9,200 1 0 1 12.4 EER COMPLIES Air Systems & Equipment - Heating System System/Equip ID Area(s) Served Heat Pump Heating Capacity Cooling Capacity AEC Proposed Heat HPH Proposed Low LTH Efficiency /Equip Heating System/Equip Type Specific Type (Btu/h) (Btu/h) Efficiency Pump Units OSA Units Compliance ID Multiplier Heating Efficiency Temp Efficiency Verification HP -1 Heat pump, vertical (SPVHP), Single package, vertical heat I 11,600 9,200 1 6.8 COP COMPLIES hearing pump Air Systems & Equipment Details System/Equip ID Area(s) Served Location In Project Documents - Plan/Detail # HP -1 P.O.S. M1.03 System/Equip ID for a single or multiple items?: Single item Economizer Compliance Method: Economizer not required WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP