Loading...
MECHANICAL COMPLIANCE SUMMARY2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2023 NEEA, All rights reserved Project & Applicant Information Project Title Earsley Investments - Yelm Detail Shop - 2018 WSEC For Building Department Use: I Date: Aug 31, 2023 Project Address 108 Yelm Ave W Yelm, WA 98597 Applicant Name Kyle Christensen Applicant Phone 253-552-2026 Applicant Email kyle@tcfarchitecture.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Services, General Building Cond. Floor Area 3,411 General Project Types New Building New Building or Addition Mechanical Scope Single Zone Systems &Equipment AlterationProject Mechanical Scope Cond. Floor Area 3,411 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Mechanical Project Description Scope and Method Scope & Space Condition in NEW BUILDING - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES Single Zone Air Systems Category - Heat pump, packaged (PTHP, SPVHP, room) Air Systems Summary Information Quantity System/Equip ID of Items Supply Airflow Control Economizer DOAS Ventilation Equipment ui Higher E Higqp Equipment Efficiency Mechanical Compliance Project Type Mechanical Scope Exception(s) Applied? Provided. Efficiency Option Applied? . Compliance Verification Scope and Method New Single Zone Systems & Y es No NA COMPLIES Load Efficiency Units Verification Building Equipment Single package, vertical 1 9,200 1 0 Additional Efficiency 12.4 EER Credits Included (AEC) HP -1 Heat pump, vertical (SPVHP), Single package, vertical heat I Does building include occupancy classifications requiring Yes Does project equipment? ro'ect include DOAS a ui ment? No DORS? COMPLIES Based on project scope do TSPR requirements apply? No Do all systems comply with Appendix D standard reference design or qualify for an exception to No TSPR. Scope & Space Condition in NEW BUILDING - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES Single Zone Air Systems Category - Heat pump, packaged (PTHP, SPVHP, room) Air Systems Summary Information Quantity System/Equip ID of Items Supply Airflow Control Ventilation Standard Ventilation CFM (Total if Multiple Items) Ventilation Air Source paired with DOAS Ventilation enerEnergy Recovery energy recovery Efficiency (/o) HP -1 I I Constant volume ASHRAE Standard 62.1 75 Integral PL Efficiency Compliance Equip ID Air Systems & Equipment - Cooling System/ Cooling System/Equip Type Specific Type Cooling Capacity AEC Efficiency Econo Exception Combined Efficiency Proposed Cooling CE Proposed Part PL Efficiency Compliance Equip ID Heating System/Equip Type Specific Type per item (Btu/h) Multiplier Multiplier (FL & PL) Multiplier (AEC & Econ o) Efficiency Units Load Efficiency Units Verification HP -1 Heat pump, vertical (SPVHP) Single package, vertical 1 9,200 1 0 1 12.4 EER COMPLIES Air Systems & Equipment - Heating System System/Equip ID Area(s) Served Heat Pump Heating Capacity Cooling Capacity AEC Proposed Heat HPH Proposed Low LTH Efficiency /Equip Heating System/Equip Type Specific Type (Btu/h) (Btu/h) Efficiency Pump Units OSA Units Compliance ID Multiplier Heating Efficiency Temp Efficiency Verification HP -1 Heat pump, vertical (SPVHP), Single package, vertical heat I 11,600 9,200 1 6.8 COP COMPLIES hearing pump Air Systems & Equipment Details System/Equip ID Area(s) Served Location In Project Documents - Plan/Detail # HP -1 P.O.S. M1.03 System/Equip ID for a single or multiple items?: Single item Economizer Compliance Method: Economizer not required WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP