Loading...
WSEC Envelope Compliance Summary Building B6/14/23, 3:00 PM waenergycodes.com/print_project_summary_form.php?k=aWQ9MTg1MjYmZnZpPTE2JmN0aT0zMQ==&print=1 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9MTg1MjYmZnZpPTE2JmN0aT0zMQ==&print=1 1/2 Administered by: ©2023 NEEA, All rights reserved Date: Jun 14, 2023 ENVELOPE COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Project & Applicant Information Project Title Tahoma Storage Building B - 2018 WSEC For Building Department Use: Project Address TBD Yelm, WA 98597 Applicant Name Neil Eugenio Applicant Phone 253-939-3232 Applicant Email neil.e@comcast.net For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type(s)Warehouse, Self-Storage Building Cond. Floor Area 3,250 Project Scope New Building Space Conditioning Categories Semi-heated Project Cond. Floor Area 3,250 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Envelope Project Description New 3,250 SF semi-heated self-storage building. Envelope Compliance Scope and Method Scope Space Conditioning Category Compliance Method WWR/SRR per Category UA Calculation Adjustment Fenestration Alternates Compliance Verification New Building Semi-heated Prescriptive 0% / 0%None selected No alternates selected COMPLIES Air Barrier Testing Air barrier testing included in project scope Air Barrier Comments Project Title Tahoma Storage Building B - 2018 WSEC Date Jun 14, 2023 Scope & Space Conditioning NEW BUILDING - SEMI-HEATED Compliance Verification COMPLIES Window-to-wall Ratio 0%Skylight-to-roof-ratio 0%Vertical Fenestration Alternate No alternates selected Opaque Envelope Assemblies Insulation R-Values Walls - Semi-heated Space Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Metal building wall A-2.1 Insulated Walls Exterior ()U-0.052 2,703 Is this assembly exterior or interior?: Exterior Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) 2nd Layer (MB Roof)U-Factor Net Area (SF) Metal building (purlins)A-4.1 Roof Exterior R-25 R-25 (< 0.04%)R-11 U-0.031 3,250 Thermal Spacer Block R-Value: R-3.5 Is liner system included?: Yes U-Factor Source: WSEC Appendix A U-Factor Source Description: Is this assembly exterior or interior?: Exterior Slab-on-grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter Length (SF) Unheated slab A-4.1 Uninsulated Slab Perimeter At grade level R-10 F-0.54 250 Slab Insulation Method: 2 ft vertical (from top of slab downward)F-Factor Source: WSEC Appendix A F-Factor Source Description: Fenestration & Opaque Door Assemblies Insulation R-Values 6/14/23, 3:00 PM waenergycodes.com/print_project_summary_form.php?k=aWQ9MTg1MjYmZnZpPTE2JmN0aT0zMQ==&print=1 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9MTg1MjYmZnZpPTE2JmN0aT0zMQ==&print=1 2/2 Opaque Doors Location in Documents Assembly ID Assembly Location Door Insulation U-Factor Rough Opening (SF) Swinging A-2.1 Door Exterior U-0.37 91 What percentage of this opaque door is glazing?: 50% or less U-Factor Source: WSEC Appendix A U-Factor Source Description:Is this assembly exterior or interior?: Exterior Is this a public entrance door?: No