Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
WSEC Lighting Compliance Summary Building E
6/15/23, 2:58 PM waenergycodes.com/print_project_summary_form.php?k=aWQ9MTkxMDQmZnZpPTE4JnJlc2V0PTE=&debug=1 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9MTkxMDQmZnZpPTE4JnJlc2V0PTE=&debug=1 1/2 Administered by: ©2023 NEEA, All rights reserved Date: Jun 15, 2023 LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Project & Applicant Information Project Title Tahoma Storage Building E - 2018 WSEC For Building Department Use: Project Address TBD Yelm, WA 98597 Applicant Name Neil Eugenio Applicant Phone 253-939-3232 Applicant Email neil.e@comcast.net For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Warehouse, Self-Storage Building Cond. Floor Area 2,150 General Project Types New Building New Building or Addition Lighting Scope Interior Lighting Alteration Lighting Scope Project Cond. Floor Area 2,150 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Lighting Project Description Self-storage lighting Building E Lighting Compliance Scope and Method Project Type Interior / Exterior (Interior includes both interior & parking)Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification New Building Interior Lighting Building area Reduced lighting power density option - 20%COMPLIES Additional Efficiency Options Included Project Title Tahoma Storage Building E - 2018 WSEC Date Jun 15, 2023 Lighting Power Calculation NEW BUILDING - INTERIOR LIGHTING Compliance Verification COMPLIES Compliance Method Building area LPA Calculation Adjustment LPA x 0.8 Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF)LPA (Watts/SF)Total Watts Allowed (SF x LPA x 0.8) Total Proposed Watts By Building Area Compliance Status by Building Area Warehouse 2,150 0.40 688 364 COMPLIES Proposed Lighting Power Density Fixture Type/Application Fixture ID Building Area New or Existing-to-Remain Quantity of Fixtures, CLDs or Luminaires (#F) Watts per Fixture, CLD or Luminaire (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Suspended L2 Warehouse New 1 24 24 Suspended L1 Warehouse New 10 34 340 Project Title Tahoma Storage Building E - 2018 WSEC Date Jun 15, 2023 Proposed Fixtures Details NEW BUILDING - INTERIOR LIGHTING Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing-to-Remain Individual Fixtures Suspended L2 A-7.1 LED Warehouse New Fixture Description:Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended L1 A-7.1 LED Warehouse New 6/15/23, 2:58 PM waenergycodes.com/print_project_summary_form.php?k=aWQ9MTkxMDQmZnZpPTE4JnJlc2V0PTE=&debug=1 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9MTkxMDQmZnZpPTE4JnJlc2V0PTE=&debug=1 2/2 Fixture Description:Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required