FA Yelm Police Dept 10-10-23FIRE ALARM SYSTEMDATE:YELM POLICE DEPARTMENT
FIRE ALARM COMMUNICATOR
206 MCKENZIE AVE
YELM, WA 98597
REVISIONS:
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________10-10-23SCALE:DRAWN BY:NLHPROJECT NUMBER:SHEET:global4security.com 360.693.1900 VANCOUVER, WAYELMPOLDEPRev#0 - ORIGINAL SUBMITTAL
FA-11 OF 1AS SHOWNDESIGNED & REVIEWED BY:NICHOLAS E.H. (NICK HAGE)NICET 153213, LEVEL: IIIFIRE ALARM SYSTEMSPART NUMBERFIRE ALARM LEGENDQTY.FIRE ALARM CONTROL PANEL (EXISTING)SILENT KNIGHTFACP5808EXIST1.DO NOT START INSTALLATION BEFORE SYSTEM IS APPROVED BY THE AHJ.2.INSTALLATION TO BE DONE PER NFPA 72 (NATIONAL FIRE ALARM & SIGNALING CODE, 2019)AND ALL OTHER APPLICABLE CODES & STANDARDS.3.VERIFY EXACT LOCATIONS AND DIMENSIONS OF PANELS AND DEVICES BEFORE ROUGH IN.4.VERIFY ALL WIRING CONNECTIONS, BACKBOXES, CONDUITS, & CABLE TYPES BEFORE INSTALLATION.5.DO NOT RUN SLC AND VOICE CABLES IN SAME CONDUIT. MAINTAIN PROPER SEPARATION.IMPORTANT NOTES1.THIS IS AN ADDITION TO AN EXISTING FIRE ALARM SYSTEM. WE WILL BE ADDING A FIRE ALARMCOMMUNICATOR TO THE EXISTING FIRE ALARM PANEL. ALL EXISTING DEVICES TO REMAIN, NOOTHER NEW DEVICES.2.INSTALL NEW FIRE ALARM COMMUNICATOR (STARLINK) ABOVE EXISTING FACP. TIE TO AUXPOWER AND DACT/TELCO CONNECTIONS ON FACP. VERIFY SIGNAL STRENGTH PRIOR TO ROUGHIN (MOUNT WITHIN TEN FEET OF FACP IN SAME ROOM). PROVIDE TWO NEW 12V-10AHBATTERIES, MINIMUM.3.TEST ENTIRE SYSTEM PRIOR TO REQUESTING FINAL INSPECTION. FURNISH RECORD OFCOMPLETION AND RELATED DOCUMENTS IN FIRE DOCUMENTS CABINET NEXT TO FACP.SCOPE OF WORK - ADD NEW FIRE COMMUNICATORSYMBOLDESCRIPTIONMANUFACTURERHORN STROBE (EXISTING)SYSTEM SENSORFIRE CELLULAR MODULE COMMUNICATORSTARLINKCELLSLE-MAXVI-FIRE1 NEWEXISTTRANSMIT ALARM TO SUPERVISING STATION
DISPLAY AT FACP & REMOTE ANNUNCIATOR
TRANSMIT SUPERVISORY TO SUPERVISING STATION
TRANSMIT TROUBLE TO SUPERVISING STATION
SOUNDS EVACUATION SIGNALC. TROUBLETO RECEIVE SEPARATE & DISTINCTSIGNALS AS FOLLOWS:CENTRAL STATION ALARM SERVICENOTES:B. SUPERVISORYA. ALARMFIRE ALARMSEQUENCEOFOPERATIONSTROUBLE CONDITION AT PANELACTIVATION OF SMOKE DETECTORLOSS OF AC POWERACTIVATION OF MANUAL PULL STATIONP2R SERIESNKEY PLAN - 206 McKENZIE AVESCALE: NTSACTIVATION OF HEAT DETECTORFEXISTSK-PULL-DASILENT KNIGHTPULL STATION (EXISTING)EXISTSK-PHOTOSILENT KNIGHTSMOKE DETECTOR (EXISTING)SEXISTSK-HEATSILENT KNIGHTHEAT DETECTOR (EXISTING)H[BATTERY](2x) 12V-10AHBACK UP BATTERIESZONE16 AWG, 2 CONDUCTOR, FPLP14 AWG, 2 CONDUCTOR, FPLP - REDABCABLE LEGEND*16 AWG, 4 CONDUCTOR, FPLPC*VERIFY ALL CABLE TYPES IN PRODUCT MANUALS / SPECS 14 AWG, 2 CONDUCTOR, FPLP - WHITEDNACANNUNAUXFIRE ALARM SYSTEM - RISER DIAGRAM2x 12V-10AHBATTERIESSK-5808TO 120VACEXISTINGSERVER/ELEC ROOMFIRE PANELSLCEXISTFIRECELLULARABOVE FACPDIALEREXISTINGTOTAL ALARMCURRENT, A10246.6790.2784.9499.0057.5040.825CURRENT, AALARMSUPERV.CURRENT, AQTYDESCRIPTIONMODULETOTAL SUPERVISORY CURRENTTOTAL ALARM AND SUPERVISORY CAPACITYTOTAL AMP-HOURS REQUIRED (AFTER 20% DERATING FACTOR)TOTAL SUPERVISORY CAPACITYTOTAL STANDBY HOURS TOTAL ALARM CAPACITYALARM PERIOD IN MINUTESTOTAL ALARM CURRENTTOTAL SUP.CURRENT, ANOTIFICATION APPLIANCES CIRCUITSPROVIDE TWO (2) 12V-10AH BATTERIES, MINIMUMBATTERY CALCULATIONS FOR FACPTOTAL CURRENT CIRCUIT #1 - EXISTING NOTIFICATION0.3650000.3650000.17000058081SILENT KNIGHT FIRE ALARM CONTROL PANEL0.1700000.0045000.000200SK-PHOTO2SILENT KNIGHT ADDRESSABLE SMOKE DETECTORTOTAL CURRENT CIRCUIT #2 - EXISTING NOTIFICATION0.0090000.000400EXISTNAC#10.0007500.000750SK-MONITOR2SILENT KNIGHT ADDRESSABLE MONITOR MODULE0.0015000.0015001.845TO EXISTING HORN-STROBESEXISTNAC#2TO EXISTING HORN-STROBES0.0045000.000200SK-HEAT0SILENT KNIGHT ADDRESSABLE HEAT DETECTOR0.0000000.0000000.3250000.085000SLE-MAXVI-FIRE1STARLINK CELLULAR FIRE COMMUNICATOR MODULE0.3250000.0850002.377PARKING LOTTO EXISTING SLC DEVICESFIREALARMNEXT TO FACPDOCUMENTSPUBLIC SAFETY BUILDING2ND STREET SE
McKENZIE AVEWASHINGTON STREET SEFACPCELL(NEW)0.0003500.000350SK-PULL-DA4SILENT KNIGHT ADDRESSABLE PULL STATION0.0014000.0014000.0250000.020000SK-58601SILENT KNIGHT FIRE REMOTE ANNUNCIATOR0.0250000.020000C,C