Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Data Sheets Yelm PD
GLOBAL SECURITY 3212 Main Street Vancouver, WA 98663 global4security.com 360.693.1900 Reference: Fire Alarm: new fire communicator Yelm P.D. / Public Safety 206 McKenzie Ave Yelm, WA 98597 Device Data Sheets 2023 IntelliKnight®5808 Single Loop Addressable Fire Alar m Control System IntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control/communicatorsystem. 5808 provides you with the revolutionary value and performance of addressable sensing technologycombined with exclusive, built-in digital communication, distributed intelligent power, easy to use interface.Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP fromSilent Knight.For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. T he convenience of an addressable firealarm control panel in a cost-effectiveeasy to use package. INTELLIKNIGHT FIRE ALARM CONTROL PANEL Model 5808 DescriptionThe basic 5808 system can be enhanced by addingmodules such as 5860 remote annunciator, 5824serial/parallel printer interface module (for printing systemreports), and 5496 intelligent power module. 5808 supportsSD or SK protocol devices. 5808 also features a powerfulbuilt-in dual line fire communicator that allows for reportingof all system activity to a remote monitoring location.Features•Built-in support for up to 99 SK detectors and 99 SKmodules.•Built in support for 127 SD devices.•Up to 125 zones and 125 output groups.•Uses standard wire—no shielded or twisted pair required•Built-in digital communicator.•Central station reporting by point or by zone•Supports Class B (Style 4) and Class A (Style 6 or 7)configuration for SLC.•Distributed, intelligent power.•Drift compensation.•13 pre-programmed output cadences, (including ANSI-3.41), and 4 programmable outputs.•Notification circuits can be configured as 2 Class A (Style Z) or 4 Class B (Style Y), or auxiliary power forresettable, constant, or door holder power.•Built-in annunciator with 80-character LCD display.•RS-485 bus provides communication to systemaccessories.•Built-in RS-232 and USB interface for programming via a PC.•Upload or download programming, event history, ordetector status via remote or direct connection.•Improvements in SKSS deliver five times fasterupload/downloads.•Built-in synchronization for appliances from AMSECO,Gentex®, Faraday, System Sensor®, and Wheelock®.•One Form C trouble relay rated at 2.5A at 27.4 VDC andtwo Form C programmable relays rated at 2.5A at 27.4VDC. •Plex-2 door option combines a dead frontcabinet door with a clear window, limitingaccess to the panel while providing singlebutton operation of the reset and silencefunctions.•Integrated dead front panel protects operatorfrom exposure to electrical components.•The FACP enclosure features a Plexiglass®viewing window to protect annunciator.•Acknowledge function allows operator to keeptrack of event status.InstallationThe 5800 can be surface or flush mounted.CompatibilityThe 5808 signal line circuit (SLC) supportsmultiple device types of the same protocol:•SK•SDYou cannot mix SD and SK SLC devices on aFACP. INTELLIKNIGHT FIRE ALARM CONTROL PANEL MADE IN AMERICA 350386 Rev. L © 2013 Honeywell International Inc. This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444.www.silentknight.com Protected Premises Unit; & Water DelugeReleasing Service. Suitable for automatic,manual, waterflow, sprinkler supervisory(DACT non-coded) signalling services.UL ListedCSFM 7165-0559:0142; MEA 429-92-E Vol. XIVOSHPD (CA) OSP-0065-10 S-BUS Accessories5860/R Remote Fire AnnunciatorFeatures the same 80 character backlitLCD display keypad and firefighter's keyswitch as the 5808. 5860 is gray and5860R is red.5496 Intelligent Power ModuleA 6 amp notification power expander thatprovides four additional power-limitednotification appliance circuit outputs.5880 LED/IO ModuleFeatures 40 LED outputs, 8 normally opendry contact inputs and one piezo output.5865-3 and 5865-4 Remote LED AnnunciatorFeatures 30 programmable LED (15 redand 15 yellow) outputs and a piezosounder. The 5865-4 adds a silence andreset switch to the package.5824 Serial/Parallel Printer Interface ModuleProvides one parallel and one RS-232serial port for connecting a printer to 5808.Use to print a real-time log of systemevents, detector status reports, and eventhistory.5883 Relay BoardFeatures 10 general purpose Form Crelays. Used with 5880 module. SpecificationsElectricalPrimary AC: 120 VRMS at 50/60 Hz,2.75ATotal Accessory Load: 6A @ 27.4VDCNotification Power: 6A @ 27.4 VDC,power-limitedStandby Current: 170 mAAlarm Current: 365 mANotification & Auxiliary Circuits: 3A @ 27.4 VDC per circuit,power-limitedBattery Charging Capacity: 7.0-35 AHBattery Size: 18 AH max. allowed inFACP. Larger capacity batteries canbe housed in an RBB accessorycabinetPhysicalFlush Mount Dimensions:14.5” W x 24.75” H x 3.5” D(36.8 W x 62.9 H x 8.73 D cm)Overall Dimensions:16" W x 26.4" H x 4.65" D(40.6 W x 67 H x 11.8 D cm)Weight: 28 lbs. (12.8 kg)Color: RedTelephone Requirements:FCC Part 15 and Part 68 approvedType of Jack: RJ31X (two required)ApprovalsNFPA 13, NFPA 15, NFPA 16, NFPA70, & NFPA 72: Central Station;Remote Signalling; Local ProtectiveSignalling Systems; Auxiliary Miscellaneous Accessories5660 Silent Knight Software SuitePC-base software for FACPprogramming. Upload and view panelaccount information, event history, anddetector status.5670 Silent Knight Software SuiteEnd-user facility management softwareallows viewing of detector status andevent history via modem or directconnection.Plex-2 DoorDead front cabinet door with clearwindow to limit access to the FACP.RBBRemote Battery Box AccessoryCabinet. Use if backup batteries aretoo large to fit into FACP cabinet.Dimensions: 16” W x 10” H x 6” D(406 mm W x 254 mm H x 152 mm D)SK-SCKSeismic Compliance KitSD and SK DevicesSee the specification sheets listedbelow for a complete listing of the SDand SK devices.53624 SD Devices data sheet53623SK Devices data sheet IntelliKnight & JumpStart are RegisteredTrademarks of Silent Knight Flexput is aTrademark of Silent Knight 5808 5496 • Universal full event sole & dual path 5G LTE-M cellular &/or IP commercial fire alarm reporting from any panel brand, virtually anywhere nationwide • Code-compliant, replaces 2 POTs lines per FACP saves thousands of dollars per year over the leased landlines. • Supports 12V-24V control panels and FACPs that communicate using Contact ID and 4/2 (such as on legacy panels), as primary or backup. • Proven StarLink Reliability & Best 5G LTE-M Performance – Works where others can’t - Signal Boost™ Circuitry & unique dual-diversity twin antennas, maximizing signal acquisition and eliminating the multiphase-effect signal-clash/ drop-outs single-antenna units are prone to. • Full data Reporting to any Central Station nationwide, via choice of Verizon® or AT&T® Networks. Communicate critical life and safety alarm reports for maximum life safety & liability protection. • Easiest installation, powered by panel, NO extra power supply, NO extra conduit. (Excludes Metal Direct AC-Powered) • Labor-Saving Features Save Time & Money - Uniquely including 4 programmable EOLR zone inputs; 2 Form C Relay outputs (no extra supervision modules to buy or in- stall); plus, 2 Telephone style jacks for easy FACP-connection. Self-supervised on 4 wires. • Preactivated - No-Delay Activation Speeds installation time, even during peak periods. • LED Status /Trouble Indicators 3 Radio Status LED Indicators (visible from outside standard model housing) - Green, Signal Strength; Amber- Busy/Activation; Red-Trouble (4 additional LEDs, not visible, for network status & troubleshooting). Power LED indicator viewable on outer metal enclosure models. • Over-the-Air Upgradable Firmware for updates w/o a truck-roll. • CLSS Support UL and NFPA 72 Fire Code-Compliant, the StarLink Max Fire Series Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal support for any brand 12V to 24V fire alarm control panel, reporting in Contact ID and 4/2. With broadest nationwide coverage footprint, Verizon or AT&T, using proven StarLink circuitry, they are also available in locking metal models. All provide the most economical solution for easy, versatile installation. Also regional compliances, i.e., CSFM, NYC FD, LAFD and more. Easy, Universal Installation at Every Application; Panel- Powered Technology™. StarLink Fire Communicators are easily connected to any panel or Fire Alarm Control Panel (FACP) standardly operating between 12V and 24V. Flexible in any application, StarLink Max Fire also comes in standard, or models in metal housings, with code-compliant supervision, and choice of power options, Panel-Powered Technology™ (powered by the panel), or direct-connect 120VAC models. Signal Boost circuitry & dual diversity antennas for maximum signal acquisition & null avoidance, receiving signals simultaneously on both antennas. One Model is Sole or Dual Path with Cellular + Internet Option. StarLink Fire provides full data reporting, in sole and dual path, as a primary or backup, to any central station of your choice, without requiring any special equipment on premises. The units are very easily activated, plans and options are selected, and 24/7 account management is provided all through www.napcocomnet.com. Napco StarLink Max® Fire Commercial Alarm Communicators • 5G LTE-M Sole or Dual Path Cell Commercial Fire Alarm Communicator in One • Choice of Nationwide Coverage Networks, Verizon or AT&T models • Choice of plans for every requirement: Simply select Cell or Cell/IP Service Plan and check-in period: 200 seconds, 5 minutes, 60 minutes, 6 hours or 24 hours. • Patented Signal Boost™ and Dual Diversity Antennae for maximum signal acquisition & null avoidance, receiving signals simultaneously on both antennas • Pro Cost-Saver Tradeup Program - Unsurpassed savings, for new and retrofit installations, replacing POTS, old radios, sunset networks and even new installations • Bonus: Full High-Speed Napco Panel remote up/downloading • COMPLIANCES: UL985, UL1023, UL1610, UL1076, UL864 10th Ed. California State Fire Marshal, NYC FD: (Note: Always “Consult with AHJ & Tech Docs /Model”, i.e., WI2465,WI2466.) 5G LTE-M Sole & Dual Path Cellular Commercial Fire Alarm Communicators 5G LTE-M STARLINK CELLULAR ® ORDERING INFO Model Type Model No. AT&T Model No. Verizon Standard ABS SLE-MAXAI-FIRE •SLE-MAXVI-FIRE • Locking Metal SLE-MAXAI-CFB •SLE-MAXVI-CFB • Metal w/Power Supply SLE-MAXAI-CFBPS •SLE-MAXVI-CFBPS • • Free FACP-Saver App - Smartphone Pro sales tool for calculating /demonstrating account’s cellular cost savings with dealer by number of lines & locations vs. copper POTs lines leased from phone co. FREE download on Apple Store or Google Play. StarLink Max Fire 5G LTE-M code-compliant standard or metal models on choice of Verizon or AT&T networks Manufacturer of Addressable, Conventional Fire Alarm Systems & Leading Commercial Fire Cellular Communications www.napcosecurity.com ©NAPCO, NAPCO Security Technologies Inc. (NADAQ:NSSC)