FA Yelm Public Services 10-11-23FIRE ALARM SYSTEMDATE:YELM PUBLIC SERVICES
FIRE ALARM COMMUNICATOR
901 N.W. RHOTON RD
YELM, WA 98597
REVISIONS:
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________10-11-23SCALE:DRAWN BY:NLHPROJECT NUMBER:SHEET:global4security.com 360.693.1900 VANCOUVER, WAYELMSERVICESRev#0 - ORIGINAL SUBMITTAL
FA-11 OF 1AS SHOWNDESIGNED & REVIEWED BY:NICHOLAS E.H. (NICK HAGE)NICET 153213, LEVEL: IIIFIRE ALARM SYSTEMSPART NUMBERFIRE ALARM LEGENDQTY.FIRE ALARM CONTROL PANEL (EXISTING)SILENT KNIGHTFACP5208EXIST1.DO NOT START INSTALLATION BEFORE SYSTEM IS APPROVED BY THE AHJ.2.INSTALLATION TO BE DONE PER NFPA 72 (NATIONAL FIRE ALARM & SIGNALING CODE, 2019)AND ALL OTHER APPLICABLE CODES & STANDARDS.3.VERIFY EXACT LOCATIONS AND DIMENSIONS OF PANELS AND DEVICES BEFORE ROUGH IN.4.VERIFY ALL WIRING CONNECTIONS, BACKBOXES, CONDUITS, & CABLE TYPES BEFORE INSTALLATION.5.DO NOT RUN SLC AND VOICE CABLES IN SAME CONDUIT. MAINTAIN PROPER SEPARATION.IMPORTANT NOTES1.THIS IS AN ADDITION TO AN EXISTING FIRE ALARM SYSTEM. WE WILL BE ADDING A FIRE ALARMCOMMUNICATOR TO THE EXISTING FIRE ALARM PANEL. ALL EXISTING DEVICES TO REMAIN, NOOTHER NEW DEVICES.2.INSTALL NEW FIRE ALARM COMMUNICATOR (STARLINK) ABOVE EXISTING FACP. TIE TO AUXPOWER AND DACT/TELCO CONNECTIONS ON FACP. VERIFY SIGNAL STRENGTH PRIOR TO ROUGHIN (MOUNT WITHIN TEN FEET OF FACP IN SAME ROOM). PROVIDE TWO NEW 12V-8AH BATTERIES,MINIMUM.3.TEST ENTIRE SYSTEM PRIOR TO REQUESTING FINAL INSPECTION. FURNISH RECORD OFCOMPLETION AND RELATED DOCUMENTS IN FIRE DOCUMENTS CABINET NEXT TO FACP.SCOPE OF WORK - ADD NEW FIRE COMMUNICATORSYMBOLDESCRIPTIONMANUFACTURERHORN STROBE (EXISTING)SYSTEM SENSORFIRE CELLULAR MODULE COMMUNICATORSTARLINKCELLSLE-MAXVI-FIRE1 NEWEXISTP2RFEXISTPS-DASILENT KNIGHTPULL STATION (EXISTING)EXIST2WBSYSTEM SENSORSMOKE DETECTOR (EXISTING)SEXIST5601PSYSTEM SENSORHEAT DETECTOR (EXISTING)H[BATTERY](2x) 12V-8AHBACK UP BATTERIESZONE16 AWG, 2 CONDUCTOR, FPLP14 AWG, 2 CONDUCTOR, FPLP - REDABCABLE LEGEND*16 AWG, 4 CONDUCTOR, FPLPC*VERIFY ALL CABLE TYPES IN PRODUCT MANUALS / SPECS 14 AWG, 2 CONDUCTOR, FPLP - WHITEDNACANNUNAUXTOTAL ALARMCURRENT, A10245.4190.2262.9937.1025.9180.499CURRENT, AALARMSUPERV.CURRENT, AQTYDESCRIPTIONMODULETOTAL SUPERVISORY CURRENTTOTAL ALARM AND SUPERVISORY CAPACITYTOTAL AMP-HOURS REQUIRED (AFTER 20% DERATING FACTOR)TOTAL SUPERVISORY CAPACITYTOTAL STANDBY HOURS TOTAL ALARM CAPACITYALARM PERIOD IN MINUTESTOTAL ALARM CURRENTTOTAL SUP.CURRENT, ANOTIFICATION APPLIANCES CIRCUITSPROVIDE TWO (2) 12V-8AH BATTERIES, MINIMUMBATTERY CALCULATIONS FOR FACPTOTAL CURRENT CIRCUIT #1 - EXISTING NOTIFICATION0.4600000.4600000.14000052081SILENT KNIGHT FIRE ALARM CONTROL PANEL0.1400000.0010000.0001002W-B8SYSTEM SENSOR SMOKE DETECTORTOTAL CURRENT CIRCUIT #3 - EXISTING NOTIFICATION0.0080000.0008000.1760.0500000.030000SK-52350SILENT KNIGHT REMOTE ANNUNCIATOR0.0000000.0000000.3250000.085000SLE-MAXVI-FIRE1STARLINK CELLULAR FIRE COMMUNICATOR MODULE0.3250000.0850001.716TRANSMIT ALARM TO SUPERVISING STATIONDISPLAY AT FACP & REMOTE ANNUNCIATORTRANSMIT SUPERVISORY TO SUPERVISING STATIONTRANSMIT TROUBLE TO SUPERVISING STATIONSOUNDS EVACUATION SIGNALC. TROUBLETO RECEIVE SEPARATE & DISTINCTSIGNALS AS FOLLOWS:CENTRAL STATION ALARM SERVICENOTES:B. SUPERVISORYA. ALARMFIRE ALARMSEQUENCEOFOPERATIONSACTIVATION OF SPRINKLER VALVE TAMPERACTIVATION OF SMOKE DETECTORACTIVATION OF SPRINKLER WATER FLOWACTIVATION OF MANUAL PULL STATIONACTIVATION OF HEAT DETECTORNKEY PLAN - 901 NW RHOTON RDSCALE: NTSYELMPUBLICSERVICESBLDGN.W. RHOTON RDFACPCELLTROUBLE CONDITION AT PANELLOSS OF AC POWERYELMWATERRECLAMATIONBLDGFIRE ALARM SYSTEM - RISER DIAGRAM2x 12V-8AHBATTERIESSK-5208TO 120VACEXISTINGFIRE PANELFIRECELLULARDIALEREXISTINGEXISTNAC#1TO EXISTING HORN-STROBESEXISTNAC#2TO EXISTING HORN-STROBESFIREALARMNEXT TO FACPDOCUMENTS(NEW)C,CEXISTNAC#3TO EXISTING OUTDOOR HORN-STROBEEXISTING ZONE 1ST FL HEAT DETECTORSEXISTING ZONE 1ST FL N. SMOKE DETECTORSEXISTING ZONE 1ST FL PULL STATIONSEXISTING ZONE 1ST FL S. SMOKE DETECTORSEXISTING ZONE 2ND FL HEAT DETECTORSEXISTING ZONE 2ND FL PULL STATIONSEXISTING ZONE 2ND FL SMOKE DETECTORSTOTAL CURRENT CIRCUIT #2 - EXISTING NOTIFICATION0.308