FA Yelm Sewer Bldg 10-12-23FIRE ALARM SYSTEMDATE:YELM SEWAGE TREATMENT
FIRE ALARM COMMUNICATOR
931 N. PACIFIC ROAD NW
YELM, WA 98597
REVISIONS:
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________
_______________________________________________________10-11-23SCALE:DRAWN BY:NLHPROJECT NUMBER:SHEET:global4security.com 360.693.1900 VANCOUVER, WAYELMSEWERRev#0 - ORIGINAL SUBMITTAL
FA-11 OF 1AS SHOWNDESIGNED & REVIEWED BY:NICHOLAS E.H. (NICK HAGE)NICET 153213, LEVEL: IIIFIRE ALARM SYSTEMSPART NUMBERFIRE ALARM LEGENDQTY.FIRE ALARM CONTROL PANEL (EXISTING)SILENT KNIGHTFACP5104EXIST1.DO NOT START INSTALLATION BEFORE SYSTEM IS APPROVED BY THE AHJ.2.INSTALLATION TO BE DONE PER NFPA 72 (NATIONAL FIRE ALARM & SIGNALING CODE, 2019)AND ALL OTHER APPLICABLE CODES & STANDARDS.3.VERIFY EXACT LOCATIONS AND DIMENSIONS OF PANELS AND DEVICES BEFORE ROUGH IN.4.VERIFY ALL WIRING CONNECTIONS, BACKBOXES, CONDUITS, & CABLE TYPES BEFORE INSTALLATION.5.DO NOT RUN SLC AND VOICE CABLES IN SAME CONDUIT. MAINTAIN PROPER SEPARATION.IMPORTANT NOTES1.THIS IS AN ADDITION TO AN EXISTING FIRE ALARM SYSTEM. WE WILL BE ADDING A FIRE ALARMCOMMUNICATOR TO THE EXISTING FIRE ALARM PANEL. ALL EXISTING DEVICES TO REMAIN, NOOTHER NEW DEVICES.2.INSTALL NEW FIRE ALARM COMMUNICATOR (STARLINK) ABOVE EXISTING FACP. TIE TO AUXPOWER AND DACT/TELCO CONNECTIONS ON FACP. VERIFY SIGNAL STRENGTH PRIOR TO ROUGHIN (MOUNT WITHIN TEN FEET OF FACP IN SAME ROOM). PROVIDE ONE NEW 12V-8AH BATTERY,MINIMUM.3.TEST ENTIRE SYSTEM PRIOR TO REQUESTING FINAL INSPECTION. FURNISH RECORD OFCOMPLETION AND RELATED DOCUMENTS IN FIRE DOCUMENTS CABINET NEXT TO FACP.SCOPE OF WORK - ADD NEW FIRE COMMUNICATORSYMBOLDESCRIPTIONMANUFACTURERHORN STROBE (EXISTING)SYSTEM SENSORFIRE CELLULAR MODULE COMMUNICATORSTARLINKCELLSLE-MAXVI-FIRE1 NEWEXISTP2RFEXISTPS-DASILENT KNIGHTPULL STATION (EXISTING)EXIST2WBSYSTEM SENSORSMOKE DETECTOR (EXISTING)SEXIST5601PSYSTEM SENSORHEAT DETECTOR (EXISTING)H[BATTERY](1x) 12V-8AHBACK UP BATTERIESZONE16 AWG, 2 CONDUCTOR, FPLP14 AWG, 2 CONDUCTOR, FPLP - REDABCABLE LEGEND*16 AWG, 4 CONDUCTOR, FPLPC*VERIFY ALL CABLE TYPES IN PRODUCT MANUALS / SPECS 14 AWG, 2 CONDUCTOR, FPLP - WHITEDNACANNUNAUXTOTAL ALARMCURRENT, A10245.4020.2250.9626.6755.5630.160CURRENT, AALARMSUPERV.CURRENT, AQTYDESCRIPTIONMODULETOTAL SUPERVISORY CURRENTTOTAL ALARM AND SUPERVISORY CAPACITYTOTAL AMP-HOURS REQUIRED (AFTER 20% DERATING FACTOR)TOTAL SUPERVISORY CAPACITYTOTAL STANDBY HOURS TOTAL ALARM CAPACITYALARM PERIOD IN MINUTESTOTAL ALARM CURRENTTOTAL SUP.CURRENT, ANOTIFICATION APPLIANCES CIRCUITSPROVIDE ONE 12V-8AH BATTERY, MINIMUMBATTERY CALCULATIONS FOR FACP0.4600000.4600000.14000051041SILENT KNIGHT FIRE ALARM CONTROL PANEL0.1400000.0010000.0001002W-B1SYSTEM SENSOR SMOKE DETECTORTOTAL CURRENT CIRCUIT #1 - EXISTING NOTIFICATION0.0010000.0001000.1760.0500000.030000SK-52300SILENT KNIGHT REMOTE ANNUNCIATOR0.0000000.0000000.3250000.085000SLE-MAXVI-FIRE1STARLINK CELLULAR FIRE COMMUNICATOR MODULE0.3250000.085000TRANSMIT ALARM TO SUPERVISING STATION
DISPLAY AT FACP
TRANSMIT SUPERVISORY TO SUPERVISING STATION
TRANSMIT TROUBLE TO SUPERVISING STATION
SOUNDS EVACUATION SIGNALC. TROUBLETO RECEIVE SEPARATE & DISTINCTSIGNALS AS FOLLOWS:CENTRAL STATION ALARM SERVICENOTES:B. SUPERVISORYA. ALARMFIRE ALARMSEQUENCEOFOPERATIONSACTIVATION OF SPRINKLER VALVE TAMPERACTIVATION OF SMOKE DETECTORACTIVATION OF SPRINKLER WATER FLOWACTIVATION OF MANUAL PULL STATIONACTIVATION OF HEAT DETECTORNKEY PLAN - 931 N. PACIFIC ROADSCALE: NTSN. PACIFIC ROADFACPCELLTROUBLE CONDITION AT PANELLOSS OF AC POWERSAFARIAUTOWRECKINGFIRE ALARM SYSTEM - RISER DIAGRAM12V-8AH BACKUPBATTERYSK-5104TO 120VACEXISTINGFIRE PANELFIRECELLULARDIALEREXISTINGEXISTNAC#1TO EXISTING HORN-STROBESFIREALARMNEXT TO FACPDOCUMENTS(NEW)C,CEXISTING ZONE - MAIN BLDG HEATS/PULLSEXISTING ZONE - STORAGE BLDG HEATS/PULLSEXISTING ZONE - SOLIDS BLDG HEATS/PULLSEXISTING ZONE - SHOP BLDG HEATS/PULLSYELMWATERRECLAMATIONCAMPUS