Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Data Sheets Yelm Sewer
GLOBAL SECURITY 3212 Main Street Vancouver, WA 98663 global4security.com 360.693.1900 Reference: Fire Alarm: new fire communicator Yelm Sewer / Water Reclamation 931 North Pacific Rd SE Yelm, WA 98597 Device Data Sheets 2023 FEATURES & BENEFITS • UL 864 Listed as an NFPA 72 Central Station or Remote Station protected premise unit • FM approved • Can be used as a stand-alone or as a add-on DACT • Six fully supervised inputs: one Class A input, and five Class B inputs • Downloadable for remote programming • 60 hours of standby power • Fuseless overload protection with automatic reset circuitry and fault indicators — eliminates the cause of most field calls. • Dual phone line interface Automatic self tests every 24 hours with report sent to central station • Reports in SIA and most major communications formats • Operates on loop start phone lines ahead of the building PBX system. • A single, programmable output is provided for alarm or dialer failed conditions (cannot be used for evacuation purposes). 5104B Fire Control Communicator The Silent Knight Model 5104B is a six-zone fire control communicator providing digital fire reporting over ordinary telephone lines, eliminating the need for costly leased lines. It’s UL 864 and NFPA 72 approved for monitoring local evacuation controls. As a stand-alone unit, it can be used to monitor: • Sprinkler systems for waterflow, supervisory, and gate valve tamper conditions. • Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours). • Monitors dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each. The Model 5104B is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone line connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition to the central station. If one of the telephone lines faults for more than 60 seconds, it will automatically switch to the other to report the failure. The communicator will signal activation, restoration and trouble conditions on any of the six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two-wire type smoke detectors, instead of the normal four-wire contact type, for automatic fire detection applications. 5104B For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Honeywell® is a registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444 5104B Technical Specifications PHYSICAL Dimensions: 12.25" W x 14.5" H x 3.0" D (31.1cm W x 36.8 cm H x 7.6cm D) Weight: 15 lbs. (6.75 kg) Color: Red ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10 to 93% relative humidity (non- condensing) ELECTRICAL: Add-on Applications - UL Listed Input: 120VAC 60Hz 40 watts CURRENT: Standby: 50mA Alarm: 135mA STAND ALONE APPLICATIONS Input: 120VAC 60Hz 40 watts Standby: 12V 7 amp hour rechargeable battery 5230 Remote Annunciator: (three maximum per system) Load: 60mA standby, 120mA alarm INDICATOR LIGHTS (LEDS) Power On: (Green) Trouble Silenced: (Yellow) Until Trouble is Cleared/Flashing: Supervisory Dialer Failure: (Yellow) Telephone Line Fault: (2 Red) Inside Cabinet at L1 and L2 Inputs TELEPHONE REQUIREMENTS FCC Registration #: AC698R-17462-AL-E RINGER EQUIVALENCE: 0.0B Type of Jack: RJ31X (2 required) ORDERING INFORMATION 5104B: Fire Alarm Communicator. Four-zone digital communication of fire and trouble. ACCESSORIES 5230: Remote Annunciator/Programmer 7181: Fire Zone Converter Module 7860: Telephone Connecting Cord for RJ31X Jack (2 required) 6712: 12 volt, 7AH rechargeable battery COMMUNICATION FORMATS: SIA, SK 3/1, Sescoa 3/1, Contact ID, SK 4/2, Radionics BFSK AGENCY LISTINGS AND APPROVALS • UL Listed - UL864/NFPA 72 Central and Remote Supervising • Station Fire Alarm System Service • FM Approved • CSFM Approved • MEA Doc 350349 | Rev F | 05/08 © 2018 Honeywell International Inc. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 • Universal full event sole & dual path 5G LTE-M cellular &/or IP commercial fire alarm reporting from any panel brand, virtually anywhere nationwide • Code-compliant, replaces 2 POTs lines per FACP saves thousands of dollars per year over the leased landlines. • Supports 12V-24V control panels and FACPs that communicate using Contact ID and 4/2 (such as on legacy panels), as primary or backup. • Proven StarLink Reliability & Best 5G LTE-M Performance – Works where others can’t - Signal Boost™ Circuitry & unique dual-diversity twin antennas, maximizing signal acquisition and eliminating the multiphase-effect signal-clash/ drop-outs single-antenna units are prone to. • Full data Reporting to any Central Station nationwide, via choice of Verizon® or AT&T® Networks. Communicate critical life and safety alarm reports for maximum life safety & liability protection. • Easiest installation, powered by panel, NO extra power supply, NO extra conduit. (Excludes Metal Direct AC-Powered) • Labor-Saving Features Save Time & Money - Uniquely including 4 programmable EOLR zone inputs; 2 Form C Relay outputs (no extra supervision modules to buy or in- stall); plus, 2 Telephone style jacks for easy FACP-connection. Self-supervised on 4 wires. • Preactivated - No-Delay Activation Speeds installation time, even during peak periods. • LED Status /Trouble Indicators 3 Radio Status LED Indicators (visible from outside standard model housing) - Green, Signal Strength; Amber- Busy/Activation; Red-Trouble (4 additional LEDs, not visible, for network status & troubleshooting). Power LED indicator viewable on outer metal enclosure models. • Over-the-Air Upgradable Firmware for updates w/o a truck-roll. • CLSS Support UL and NFPA 72 Fire Code-Compliant, the StarLink Max Fire Series Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal support for any brand 12V to 24V fire alarm control panel, reporting in Contact ID and 4/2. With broadest nationwide coverage footprint, Verizon or AT&T, using proven StarLink circuitry, they are also available in locking metal models. All provide the most economical solution for easy, versatile installation. Also regional compliances, i.e., CSFM, NYC FD, LAFD and more. Easy, Universal Installation at Every Application; Panel- Powered Technology™. StarLink Fire Communicators are easily connected to any panel or Fire Alarm Control Panel (FACP) standardly operating between 12V and 24V. Flexible in any application, StarLink Max Fire also comes in standard, or models in metal housings, with code-compliant supervision, and choice of power options, Panel-Powered Technology™ (powered by the panel), or direct-connect 120VAC models. Signal Boost circuitry & dual diversity antennas for maximum signal acquisition & null avoidance, receiving signals simultaneously on both antennas. One Model is Sole or Dual Path with Cellular + Internet Option. StarLink Fire provides full data reporting, in sole and dual path, as a primary or backup, to any central station of your choice, without requiring any special equipment on premises. The units are very easily activated, plans and options are selected, and 24/7 account management is provided all through www.napcocomnet.com. Napco StarLink Max® Fire Commercial Alarm Communicators • 5G LTE-M Sole or Dual Path Cell Commercial Fire Alarm Communicator in One • Choice of Nationwide Coverage Networks, Verizon or AT&T models • Choice of plans for every requirement: Simply select Cell or Cell/IP Service Plan and check-in period: 200 seconds, 5 minutes, 60 minutes, 6 hours or 24 hours. • Patented Signal Boost™ and Dual Diversity Antennae for maximum signal acquisition & null avoidance, receiving signals simultaneously on both antennas • Pro Cost-Saver Tradeup Program - Unsurpassed savings, for new and retrofit installations, replacing POTS, old radios, sunset networks and even new installations • Bonus: Full High-Speed Napco Panel remote up/downloading • COMPLIANCES: UL985, UL1023, UL1610, UL1076, UL864 10th Ed. California State Fire Marshal, NYC FD: (Note: Always “Consult with AHJ & Tech Docs /Model”, i.e., WI2465,WI2466.) 5G LTE-M Sole & Dual Path Cellular Commercial Fire Alarm Communicators 5G LTE-M STARLINK CELLULAR ® ORDERING INFO Model Type Model No. AT&T Model No. Verizon Standard ABS SLE-MAXAI-FIRE •SLE-MAXVI-FIRE • Locking Metal SLE-MAXAI-CFB •SLE-MAXVI-CFB • Metal w/Power Supply SLE-MAXAI-CFBPS •SLE-MAXVI-CFBPS • • Free FACP-Saver App - Smartphone Pro sales tool for calculating /demonstrating account’s cellular cost savings with dealer by number of lines & locations vs. copper POTs lines leased from phone co. FREE download on Apple Store or Google Play. StarLink Max Fire 5G LTE-M code-compliant standard or metal models on choice of Verizon or AT&T networks Manufacturer of Addressable, Conventional Fire Alarm Systems & Leading Commercial Fire Cellular Communications www.napcosecurity.com ©NAPCO, NAPCO Security Technologies Inc. (NADAQ:NSSC)