Tahoma Terra-II - Building G - Envelope SetSEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:33:55 PMTAHOMA TERRA APARTMENTS PHASE II NEW APARTMENT COMPLEX PERMIT SET - 08.02.23 ENV0.0 ENVELOPE GENERAL NOTES PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI PROJECT INFORMATION PROJECT NAME: PROJECT ADDRESS: TAHOMA TERRA APARTMENTS PHASE II 9955 TAHOMA BOULEVARD SE YELM, WA 98597 BUILDING ENVELOPE CONSULTANT TEAM NEXUS bec 253.625.7090 747 FAWCETT AVE, SUITE C TACOMA, WA 98402 BUILDING ENVELOPE DESIGNER: DANI ITTNER dittner@nexusbec.com SHEET INDEX SHEET TITLE ENV0.0 ENVELOPE GENERAL NOTES ENV0.1 AIR BARRIER EXTENTS DIAGRAMS - BUILDINGS A, B, D, E, & F ENV0.2 AIR BARRIER EXTENTS DIAGRAMS - BUILDING C ENV0.3 AIR BARRIER EXTENTS DIAGRAMS - BUILDING H ENV0.4 AIR BARRIER EXTENTS DIAGRAMS - BUILDING G ENV2.0 WALL SECTIONS ENV2.1 WALL SECTIONS ENV3.0 FOUNDATION DETAILS ENV4.0 DOOR DETAILS ENV4.1 WINDOW DETAILS ENV4.5 FENESTRATION FLASHING SEQUENCING DETAIL ENV4.6 FENESTRATION FLASHING SEQUENCING DETAIL ENV5.0 TYPICAL AIR BARRIER DETAILS ENV5.1 WALL PENETRATIONS AND CLADDING DETAILS ENV5.2 WALL PENETRATIONS AND CLADDING DETAILS ENV5.3 WALL PENETRATIONS AND CLADDING DETAILS ENV6.0 DECK DETAILS ENV7.0 ROOF DETAILS ENV7.1 ROOF DETAILS FIELD TESTING REQUIREMENTS TESTED SYSTEM OR ASSEMBLY QUANTITY TEST STANDARD WINDOW WATER PENETRATION RESISTANCE TBD ASTM E1105 WHOLE BUILDING AIR BARRIER 1 ASTM E779 THE FOLLOWING FIELD TESTS OF BUILDING ENVELOPE COMPONENTS, SYSTEMS, AND ASSEMBLIES WILL BE PERFORMED BY THE BUILDING ENVELOPE CONSULTANT OR TESTING AGENCY APPROVED BY BUILDING ENVELOPE CONSULTANT. THE CONTRACTOR SHALL COORDINATE SCHEDULING OF TESTS WITH THE BUILDING ENVELOPE CONSULTANT, INCLUDING A PRE-TEST WALK-THRU AND REVIEW OF TESTING REQUIREMENTS. TESTING QUANTITIES LISTED MAY BE MODIFIED AT ANY TIME BY THE BUILDING ENVELOPE CONSULTANT, WITH APPROVAL OF THE OWNER. TESTING WILL BE PERFORMED DURING REGULAR BUSINESS HOURS AS HELD BY THE BUILDING ENVELOPE CONSULTANT. ABBREVIATIONS ARCH ARCHITECTURAL B.O.BOTTOM OF ELEV ELEVATION FFE FINISH FLOOR ELEVATION OR TOP OF SUB-FLOOR DATUM OC ON CENTER PERP PERPENDICULAR PPT PRESERVATIVE PRESSURE TREATED STR STRUCTURAL TBD TO BE DETERMINED T.O.TOP OF UNO UNLESS NOTED OTHERWISE WSEC WASHINGTON STATE ENERGY CODE ENVELOPE MATERIALS GENERAL NOTES 1. DRAWINGS ARE INTENDED TO DESCRIBE REQUIREMENTS OF THE BUILDING ENVELOPE WITH RESPECT TO THERMAL PERFORMANCE, AIR CONTROL, VAPOR CONTROL, AND WATER MANAGEMENT. REFER TO ARCHITECTURAL DRAWINGS FOR CLADDING TYPES, FINISHES, AND WALL ASSEMBLIES. REFER TO STRUCTURAL DRAWINGS FOR LOCATIONS AND REQUIREMENTS FOR ALL STRUCTURAL ELEMENTS INCLUDING, BUT NOT LIMITED TO, CONCRETE, FRAMING, SHEATHING, AND STEEL. 2. DETAILING PROVIDED HEREIN IS BASED ON CRITERIA LISTED ON THIS PAGE. ANY CHANGES TO BUILDING DESIGN, CONSTRUCTION, OR BARRIER SYSTEMS USED MAY REQUIRE REVISIONS TO DETAILS. 3. DO NOT SUBSTITUTE BUILDING ENVELOPE MATERIALS SPECIFIED WITHOUT RECEIVING WRITTEN APPROVAL FROM BUILDING ENVELOPE CONSULTANT AND ARCHITECT. 4. CONSULT ARCHITECTURAL PLANS FOR LOCATIONS AND INFORMATION ON DESIGN ELEMENTS NOT SHOWN OR NOTED HEREIN. 5. WORK TO BE COMPLETED IN ACCORDANCE WITH REGULATIONS AND CODE AS STIPULATED ON THE ARCHITECTURAL DRAWINGS. 6. NOTIFY BUILDING ENVELOPE CONSULTANT DESIGNER PRIOR TO COMMENCEMENT OF WORK IF DISCREPANCIES FOUND BETWEEN THE BUILDING ENVELOPE DRAWINGS AND; CONTRACT DOCUMENTS, SITE CONDITIONS, MANUFACTURER RECOMMENDATIONS, CODES OR REGULATIONS OF AUTHORITY HAVING JURISDICTION, OR COORDINATION BETWEEN ARCHITECTURAL, STRUCTURAL, CIVIL, LANDSCAPE, MECHANICAL, OR ELECTRICAL DRAWINGS. 7. DO NOT SCALE DRAWINGS. REFER TO ARCHITECTURAL DRAWINGS FOR CONFIRMATION OF DIMENSIONS. 8. REFER TO MATERIAL DATA SHEETS AND MANUFACTURERS INSTRUCTIONS WITH RESPECT TO COMPATIBILITY BETWEEN MATERIALS. PRE-CONSTRUCTION MEETING A PRE-CONSTRUCTION MEETING OR MEETINGS IS RECOMMENDED WITH THE VARIOUS TRADES TO REVIEW THE DESIGN INTENT AND MATERIAL SPECIFICATIONS PRIOR TO PROCEEDING WITH WORK ON THE FOLLOWING SYSTEMS: • BELOW-GRADE WATERPROOFING • PEDESTRIAN TRAFFIC COATING • WINDOWS / DOORS • WEATHER RESISTIVE BARRIER(S) • WALL CLADDING • ROOFING FIELD INSPECTIONS FIELD INSPECTIONS WILL BE PERFORMED BY THE BUILDING ENVELOPE CONSULTANT INSPECTOR. THE CONTRACTOR SHALL COORDINATE SCHEDULING OF INSPECTIONS WITH THE INSPECTOR, INCLUDING PROVIDING THE INSPECTOR WITH A CURRENT CONSTRUCTION SCHEDULE AND ALLOWING FOR 48 HOUR MINIMUM NOTICE PRIOR TO INSPECTION. AT LEAST TWO INSPECTIONS WILL BE PERFORMED ON EACH BUILDING. DETAILS TO BE INSPECTED ARE LISTED ACCORDING TO SYSTEM ELSEWHERE ON THIS SHEET. MOCK-UP REVIEW THE BUILDING ENVELOPE CONSULTANT INSPECTOR WILL CONDUCT A REVIEW OF A FIELD MOCK-UP(S) THAT INCLUDES OBSERVABLE STEP-BY-STEP INSTALLATION OF THE FOLLOWING COMPONENTS: • WEATHER RESISTIVE BARRIER(S) • TYPICAL WALL PENETRATIONS AND FLASHING • WINDOW • DOOR ENVELOPE SYSTEMS BELOW GRADE WATERPROOFING BELOW GRADE WATERPROOFING SYSTEM SHALL BE INSTALLED PER MANUFACTURERS REQUIREMENTS. DETAILS MAY VARY IF WATERPROOFING SYSTEM USED IS DIFFERENT THAN THE BASIS OF DESIGN SYSTEM. THE FOLLOWING DETAILS SHALL BE INCLUDED IN CONSTRUCTION MADE AVAILABLE TO REVIEW DURING SITE INSPECTIONS. THIS LIST IS NOT EXHAUSTIVE AND ADDITIONAL DETAILS MAY BE REQUESTED BY THE BUILDING ENVELOPE CONSULTANT. • WATERPROOFING TERMINATION AT FOOTING • FOOTING DRAIN • WATERPROOFING TERMINATION AT TOP OF WALL • WATERPROOFING PENETRATION • VAPOR BARRIER PENETRATION • VAPOR BARRIER TERMINATION DECK WATERPROOFING PEDESTRIAN TRAFFIC COATING SYSTEM SHALL BE INSTALLED PER MANUFACTURERS REQUIREMENTS. DETAILS MAY VARY IF WATERPROOFING SYSTEM USED IS DIFFERENT THAN THE BASIS OF DESIGN SYSTEM. THE FOLLOWING DETAILS SHALL BE INCLUDED IN CONSTRUCTION MADE AVAILABLE TO REVIEW DURING SITE INSPECTIONS. THIS LIST IS NOT EXHAUSTIVE AND ADDITIONAL DETAILS MAY BE REQUESTED BY THE BUILDING ENVELOPE CONSULTANT. FLOOD TESTING MAY BE REQUIRED. • WATERPROOFING AT DRIP EDGE FLASHINGS • WATERPROOFING AT BASE OF WALL • WATERPROOFING AT DOOR SILL WEATHER RESISTIVE BARRIER(S) WEATHER RESISTIVE BARRIER(S) SHALL BE INSTALLED PER MANUFACTURERS REQUIREMENTS. DETAILS MAY VARY IF WEATHER RESISTIVE BARRIER USED IS DIFFERENT THAN THE BASIS OF DESIGN SYSTEM. THE FOLLOWING DETAILS SHALL BE INCLUDED IN CONSTRUCTION MADE AVAILABLE TO REVIEW DURING SITE INSPECTIONS. THE WEATHER RESISIVE BARRIER MUST BE VISIBLE DURING THESE INSPECTIONS AND NOT COVERED WITH CLADDING. THIS LIST IS NOT EXHAUSTIVE AND ADDITIONAL DETAILS MAY BE REQUESTED BY THE BUILDING ENVELOPE CONSULTANT. • BOTTOM OF WALL FLASHING • THRU-WALL FLASHING • TYPICAL PENETRATION • SHEET METAL VENT BOX • KNIFE PLATE ROOFING ROOFING SYSTEM SHALL BE INSTALLED PER MANUFACTURERS REQUIREMENTS. DETAILS MAY VARY IF ROOFING SYSTEM USED IS DIFFERENT THAN THE BASIS OF DESIGN SYSTEM. THE FOLLOWING DETAILS SHALL BE INCLUDED IN CONSTRUCTION MADE AVAILABLE TO REVIEW DURING SITE INSPECTIONS. THIS LIST IS NOT EXHAUSTIVE AND ADDITIONAL DETAILS MAY BE REQUESTED BY THE BUILDING ENVELOPE CONSULTANT. • PERIMETER FLASHINGS (STEP FLASHINGS AND DRIP EDGES) • VALLEY FLASHING • TYPICAL PENETRATIONS • GUTTER AIR BARRIER 1. THESE BUILDINGS ARE DESIGNED WITH AN AIR BARRIER PER THE REQUIREMENTS OF THE 2018 WSEC (RESIDENTIAL PROVISIONS) SECTION C402.4. 2. AIR BARRIER MATERIALS AND SYSTEMS ARE DESIGNATED ON ARCHITECTURAL ASSEMBLY SHEETS AND IN THE SPECIFICATION. DETAILS PROVIDED HEREIN SHOW CONNECTIONS BETWEEN ADJACENT SYSTEMS AND PEPENTRATIONS. 3. MATERIALS NOTED WITH "(AIR BARRIER)" ARE AIR BARRIER COMPONENTS AND MUST BE INSTALLED AS DETAILED TO ENSURE AIR BARRIER CONTINUITY. 4. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING TRADES INVOLVED IN AIR BARRIER INSTALLATION AND PROTECTING INSTALLED SYSTEMS/MATERIALS FROM DAMAGE BY ADJACENT TRADES. 5. TESTING SHALL BE COMPLETED IN ACCORDANCE WITH THE 2018 WSEC (RESIDENTIAL PROVISIONS) SECTION C402.4.1.2. THE FOLLOWING IS A SUMMARY OF THE MATERIALS REPRESENTED IN THIS DRAWING SET BELOW GRADE WATERPROOFING COLD FLUID-APPLIED WATERROOFING MEMBRANE TREMCO; TREMPROOF 260 DRAINAGE MAT DRAINAGE BOARD TREMCO; TREMDRAIN 1000 BELOW GRADE RIGID INSULATION EXTRUDED POLYSTYRENE (XPS) UNDER SLAB VAPOR BARRIER 6 MIL HD POLYETHYLENE SHEET STEGO; STEGOCRAWL PEDESTRIAN TRAFFIC COATING FLUID-APPLIED POLYURETHANE WATERPROOFING SYSTEM TREMCO; VULKEM 350/351 OR VULKEN 360NF/951NF WATER BARRIER SYSTEM VAPOR PERMEABLE, SPUNBONDED POLYOLEFIN, NON-WOVEN, NON-PERFORATED SHEET AIR AND WATER BARRIER SYSTEM DUPONT; TYVEK COMMERCIAL WRAP DRAINABLE WATER BARRIER SYSTEM VAPOR PERMEABLE, SPUNBONDED POLYOLEFIN, NON-WOVEN, NON-PERFORATED SHEET AIR AND WATER BARRIER SYSTEM DUPONT; TYVEK COMMERCIAL WRAP FLEXIBLE FLASHING DUPONT; STRAIGHTFLASH SELF-ADHERED MEMBRANE DUPONT; FLEXWRAP EXTERIOR RIGID INSULATION (ABOVE GRADE) FOIL-FACED POLYISOCYANURATE INSULATION DOW;THERMAX CI SEALANT SILICONE SEALANT DOW; DOWSIL 758 FIBER CEMENT LAP 5/16" THICK FIBER CEMENT PLANKS WITH 1x CEDAR TRIM JAMES HARDIE; HARDIPLANK 6" EXPOSURE FIBER CEMENT SHINGLES 5/16" THICK FIBER CEMENT SHINGLES WITH 1x CEDAR TRIM JAMES HARDIE; HARDISHINGLE FIBER CEMENT BOARD AND BATT 5/16" THICK FIBER CEMENT PANELS WITH FIBER CEMENT BATTENS AND 1x CEDAR TRIM JAMES HARDIE; HARDIPANEL THIN STONE VENEER DRY STACK CULTURED STONE IN MORTAR BED ON SELF-FURRING LATH ELDORADO; TBD SHEET METAL FLASHINGS PRE-FINISHED OR PRE-PRIMED 24 GA SHEET METAL, SHAPE AS SHOWN IN DRAWINGS, WITH HOT DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS WINDOWS FLANGED VINYL WINDOWS -PERFORMANCE RATING LC25 MIN TBD DOORS FIBERGLASS DOOR IN COMPOSITE FRAME TBD ROOFING SYSTEM ASPHALT SHINGLES OVER SYNTHETIC UNDERLAYMENT WITH ICE AND WATER SHIELD AT PERIMETER AND VALLEYS AND SHEET METAL VALLEYS TBD RCW 64.55 THE UNDERSIGNED HAS PROVIDED BUILDING ENCLOSURE DOCUMENTS THAT IN MY PROFESSIONAL JUDGEMENT ARE APPROPRIATE TO SATISFY THE REQUIREMENTS OF RCW 64.55.005 THROUGH 64.55.090. 2 ENV0.1 _______ 1 ENV0.1 _______ 1 11 1 1 1 1 1 1 1 11 1 1 1 111 1 1 1 2 ENV0.1 _______ 1 ENV0.1 _______ 1 11 1 1 1 1 1 1 1 11 1 1 11 1 1 1 2 ENV0.1 _______ 1 ENV0.1 _______ 11 1 1 1 1 1 1 1 1 1 1 1 ENV0.1 _______ 2 11 3 3 3 2 ENV0.1 _______ 22 1 3 3 1 1 3 1 1 3 BUILDING AIR BARRIER SYSTEM PERFORMANCE REQUIREMENT INSTALL A CONTINUOUS BUILDING AIR BARRIER SYSTEM OVER THE ENTIRE EXTERIOR ENVELOPE (ROOF, WALLS, AND FLOOR) SEPARATING THE INTERIOR CONDITIONED AIR FROM THE EXTERIOR UNCONDITIONED AIR WITH AN AIR LEAKAGE RATE NOT EXCEEDING 0.40 CFM PER SQUARE FOOT OF EXTERIOR ENVELOPE AREA AT 75 Pa OR 0.3 Wg. THE CONTINUOUS AIR BARRIER SYSTEM INCLUDES AIR TIGHT CONNECTIONS TO ANY PENETRATIONS, WINDOWS, DOORS, LOUVERS, AND BETWEEN ADJACENT DIFFERENT TYPES OF AIR BARRIER SYSTEMS. LEGEND BUILDING AIR BARRIER PRESSURE BOUNDARY KEYNOTES EXTERIOR WALL -FRAMED WALL -GYPSUM WALLBOARD AIR BARRIER FLOOR -SLAB ON GRADE -CONCRETE AIR BARRIER CEILING -FRAMED CEILING -GYPSUM WALLBOARD AIR BARRIER GENERAL NOTES THESE PLANS AND SECTIONS ARE DIAGRAMMATIC AND INTENDED ONLY TO SHOW WHOLE BUILDING AIR BARRIER SYSTEM PRESSURE BOUNDARY TO BE TESTED. REFER TO BUILDING PLANS, ASSEMBLIES, SECTIONS, AND DETAILS FOR ACTUAL AIR BARRIER SYSTEM LOCATIONS AND EXTENTS. 1 2 3 ENVELOPE AREA WALLS XXX SF FLOORS XXX SF ROOF XXX SF TOTAL XXX SF SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:33:57 PMENV0.1 AIR BARRIER EXTENTS DIAGRAMS - BUILDINGS A, B, D, E, & F PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXAJL DMI 1/16" = 1'-0"3 AIR BARRIER PRESSURE BOUNDARY - L1 PLAN 1/16" = 1'-0"4 AIR BARRIER PRESSURE BOUNDARY - L2 PLAN 1/16" = 1'-0"5 AIR BARRIER PRESSURE BOUNDARY - L3 PLAN 1/16" = 1'-0"2 AIR BARRIER PRESSURE BOUNDARY - BUIDLING SECTION 1/16" = 1'-0"1 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION 2 ENV0.2 _______ 1 ENV0.2 _______ 3 ENV0.2 _______ 1 11 1 1 1 1 1 11 1 1 1 111 1 1 1 11 1 111 1 1 1 11 1 1 1 1 1 1 1 1 2 ENV0.2 _______ 1 ENV0.2 _______ 3 ENV0.2 _______ 1 11 1 1 1 1 1 11 1 1 111 1 1 11 1 111 1 1 1 11 1 1 1 1 1 1 2 ENV0.2 _______ 1 ENV0.2 _______ 3 ENV0.2 _______ 1 11 1 1 1 1 1 11 1 11 11 1 111 1 1 1 11 1 1 1 ENV0.2 _______ 2 11 3 3 3 2 ENV0.2 _______3 ENV0.2 _______ 22 1 3 31 1 3 1 1 3 21 3 1 ENV0.2 _______ 2 11 3 BUILDING AIR BARRIER SYSTEM PERFORMANCE REQUIREMENT INSTALL A CONTINUOUS BUILDING AIR BARRIER SYSTEM OVER THE ENTIRE EXTERIOR ENVELOPE (ROOF, WALLS, AND FLOOR) SEPARATING THE INTERIOR CONDITIONED AIR FROM THE EXTERIOR UNCONDITIONED AIR WITH AN AIR LEAKAGE RATE NOT EXCEEDING 0.40 CFM PER SQUARE FOOT OF EXTERIOR ENVELOPE AREA AT 75 Pa OR 0.3 Wg. THE CONTINUOUS AIR BARRIER SYSTEM INCLUDES AIR TIGHT CONNECTIONS TO ANY PENETRATIONS, WINDOWS, DOORS, LOUVERS, AND BETWEEN ADJACENT DIFFERENT TYPES OF AIR BARRIER SYSTEMS. LEGEND BUILDING AIR BARRIER PRESSURE BOUNDARY KEYNOTES EXTERIOR WALL -FRAMED WALL -GYPSUM WALLBOARD AIR BARRIER FLOOR -SLAB ON GRADE -CONCRETE AIR BARRIER CEILING -FRAMED CEILING -GYPSUM WALLBOARD AIR BARRIER GENERAL NOTES THESE PLANS AND SECTIONS ARE DIAGRAMMATIC AND INTENDED ONLY TO SHOW WHOLE BUILDING AIR BARRIER SYSTEM PRESSURE BOUNDARY TO BE TESTED. REFER TO BUILDING PLANS, ASSEMBLIES, SECTIONS, AND DETAILS FOR ACTUAL AIR BARRIER SYSTEM LOCATIONS AND EXTENTS. 1 2 3 ENVELOPE AREA WALLS XXX SF FLOORS XXX SF ROOF XXX SF TOTAL XXX SF SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:33:59 PMENV0.2 AIR BARRIER EXTENTS DIAGRAMS - BUILDING C PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXAJL DMI 1/16" = 1'-0"4 AIR BARRIER PRESSURE BOUNDARY - L1 PLAN 1/16" = 1'-0"5 AIR BARRIER PRESSURE BOUNDARY - L2 PLAN 1/16" = 1'-0"6 AIR BARRIER PRESSURE BOUNDARY - L3 PLAN 1/16" = 1'-0"2 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION 1/16" = 1'-0"1 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION 1/16" = 1'-0"3 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION 5 ENV0.3 _______4 ENV0.3 _______ 1 ENV0.3 _______ 3 ENV0.3 _______6 ENV0.3 _______ 1 1 11 1 1 1 11 1 1 11 1 1 1 1 1 1 1 1 1 1 1 2 ENV0.3 _______ 5 ENV0.3 _______4 ENV0.3 _______ 1 ENV0.3 _______ 3 ENV0.3 _______6 ENV0.3 _______ 1 1 1 11 1 1 1 1 1 1 1 1 3 2 ENV0.3 _______ 5 ENV0.3 _______4 ENV0.3 _______ 1 ENV0.3 _______ 3 ENV0.3 _______6 ENV0.3 _______ 1 1 1 11 1 1 1 1 1 2 ENV0.3 _______ 1 ENV0.3 _______ 2 11 3 3 3 2 ENV0.3 _______ 1 ENV0.3 _______ 2 11 3 2 ENV0.3 _______ 1 ENV0.3 _______ 2 1 3 3 1 1 3 1 2 ENV0.3 _______ 1 ENV0.3 _______ 2 1 3 3 1 3 2 ENV0.3 _______ 5 ENV0.3 _______4 ENV0.3 _______3 ENV0.3 _______6 ENV0.3 _______ 2 1 3 3 1 1 3 33 2 1 BUILDING AIR BARRIER SYSTEM PERFORMANCE REQUIREMENT INSTALL A CONTINUOUS BUILDING AIR BARRIER SYSTEM OVER THE ENTIRE EXTERIOR ENVELOPE (ROOF, WALLS, AND FLOOR) SEPARATING THE INTERIOR CONDITIONED AIR FROM THE EXTERIOR UNCONDITIONED AIR WITH AN AIR LEAKAGE RATE NOT EXCEEDING 0.40 CFM PER SQUARE FOOT OF EXTERIOR ENVELOPE AREA AT 75 Pa OR 0.3 Wg. THE CONTINUOUS AIR BARRIER SYSTEM INCLUDES AIR TIGHT CONNECTIONS TO ANY PENETRATIONS, WINDOWS, DOORS, LOUVERS, AND BETWEEN ADJACENT DIFFERENT TYPES OF AIR BARRIER SYSTEMS. LEGEND BUILDING AIR BARRIER PRESSURE BOUNDARY KEYNOTES EXTERIOR WALL -FRAMED WALL -GYPSUM WALLBOARD AIR BARRIER FLOOR -SLAB ON GRADE -CONCRETE AIR BARRIER CEILING -FRAMED CEILING -GYPSUM WALLBOARD AIR BARRIER GENERAL NOTES THESE PLANS AND SECTIONS ARE DIAGRAMMATIC AND INTENDED ONLY TO SHOW WHOLE BUILDING AIR BARRIER SYSTEM PRESSURE BOUNDARY TO BE TESTED. REFER TO BUILDING PLANS, ASSEMBLIES, SECTIONS, AND DETAILS FOR ACTUAL AIR BARRIER SYSTEM LOCATIONS AND EXTENTS. 1 2 3 ENVELOPE AREA WALLS XXX SF FLOORS XXX SF ROOF XXX SF TOTAL XXX SF 5 ENV0.3 _______4 ENV0.3 _______3 ENV0.3 _______6 ENV0.3 _______ 2 1 3 1 1 1 3 SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:01 PMENV0.3 AIR BARRIER EXTENTS DIAGRAMS - BUILDING H PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXAJL DMI 1/16" = 1'-0"7 AIR BARRIER PRESSURE BOUNDARY - L1 PLAN 1/16" = 1'-0"8 AIR BARRIER PRESSURE BOUNDARY - L2 PLAN 1/16" = 1'-0"9 AIR BARRIER PRESSURE BOUNDARY - L3 PLAN 1/16" = 1'-0"5 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION 1/16" = 1'-0"4 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION 1/16" = 1'-0"6 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION 1/16" = 1'-0"3 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION 1/16" = 1'-0"1 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION 1/16" = 1'-0"2 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION 2 ENV0.4 _______ 1 ENV0.4 _______ 1 1 11 1 1 1 111 1 1 11 1 1 1 1 1 1 1 1 2 ENV0.4 _______ 1 ENV0.4 _______ 1 1 11 1 1 1 111 1 1 11 1 1 1 1 1 1 2 ENV0.4 _______ 1 ENV0.4 _______ 1 1 1 1 11 1 1 11 1 1 1 1 1 1 1 ENV0.4 _______ 2 11 3 3 3 2 ENV0.4 _______ 22 1 3 1 3 1 BUILDING AIR BARRIER SYSTEM PERFORMANCE REQUIREMENT INSTALL A CONTINUOUS BUILDING AIR BARRIER SYSTEM OVER THE ENTIRE EXTERIOR ENVELOPE (ROOF, WALLS, AND FLOOR) SEPARATING THE INTERIOR CONDITIONED AIR FROM THE EXTERIOR UNCONDITIONED AIR WITH AN AIR LEAKAGE RATE NOT EXCEEDING 0.40 CFM PER SQUARE FOOT OF EXTERIOR ENVELOPE AREA AT 75 Pa OR 0.3 Wg. THE CONTINUOUS AIR BARRIER SYSTEM INCLUDES AIR TIGHT CONNECTIONS TO ANY PENETRATIONS, WINDOWS, DOORS, LOUVERS, AND BETWEEN ADJACENT DIFFERENT TYPES OF AIR BARRIER SYSTEMS. LEGEND BUILDING AIR BARRIER PRESSURE BOUNDARY KEYNOTES EXTERIOR WALL -FRAMED WALL -GYPSUM WALLBOARD AIR BARRIER FLOOR -SLAB ON GRADE -CONCRETE AIR BARRIER CEILING -FRAMED CEILING -GYPSUM WALLBOARD AIR BARRIER GENERAL NOTES THESE PLANS AND SECTIONS ARE DIAGRAMMATIC AND INTENDED ONLY TO SHOW WHOLE BUILDING AIR BARRIER SYSTEM PRESSURE BOUNDARY TO BE TESTED. REFER TO BUILDING PLANS, ASSEMBLIES, SECTIONS, AND DETAILS FOR ACTUAL AIR BARRIER SYSTEM LOCATIONS AND EXTENTS. 1 2 3 ENVELOPE AREA WALLS XXX SF FLOORS XXX SF ROOF XXX SF TOTAL XXX SF SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:03 PMENV0.4 AIR BARRIER EXTENTS DIAGRAMS - BUILDING G PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXAJL DMI 1/16" = 1'-0"3 AIR BARRIER PRESSURE BOUNDARY - L1 PLAN 1/16" = 1'-0"4 AIR BARRIER PRESSURE BOUNDARY - L2 PLAN 1/16" = 1'-0"5 AIR BARRIER PRESSURE BOUNDARY - L3 PLAN 1/16" = 1'-0"2 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION 1/16" = 1'-0"1 AIR BARRIER PRESSURE BOUNDARY - BUILDING SECTION EXTERIORINTERIOR 4 ENV4.0 _______ AT WALL AT DOOR ENV6.0 6 ENV6.0 1 ENV5.1 9 ENV5.2 3 ENV5.1 8 ENV7.0 6 ENV7.0 7 ENV6.0 2 ENV7.0 3 ENV5.2 1 ENV5.2 2 ENV5.1 11 ENV7.0 5 SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:03 PMENV2.0 WALL SECTIONS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 1 1/2" = 1'-0"1 SECTION AT DECK 1 1/2" = 1'-0"2 SECTION AT AWNING AT STAIR ENV7.0 11 ENV7.0 3 ENV7.0 4 SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:03 PMENV2.1 WALL SECTIONS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 1 1/2" = 1'-0"1 ROOF SECTION AT BREEZEWAY EXTERIORINTERIOR ENV3.0 3 WALL ASSEMBLY PER ARCHITECTURAL MIXED DRAIN ROCK FOOTING DRAIN FILTER FABRIC DAMPPROOFING EXTERIORINTERIOR SIDEWALK/PAVING PER SITE PLAN WALL ASSEMBLY PER ARCHITECTURAL ENV3.0 4 MIXED DRAIN ROCK FOOTING DRAIN FILTER FABRIC DAMPPROOFING EXTERIORINTERIOR UNDER SLAB VAPOR BARRIER, TAPE ALL PENETRATIONS AND PERIMETER PER MANUFACTURER TYPICAL DETAILS SHEET METAL FLASHING WATER BARRIER SYSTEM 6" MINSEE TYPICAL AIR BARRIER DETAILS FOR AIR SEALING NOTES (AIR BARRIER) EXTERIORINTERIOR UNDER SLAB VAPOR BARRIER, TAPE ALL PENETRATIONS AND PERIMETER PER MANUFACTURER TYPICAL DETAILS SEE TYPICAL AIR BARRIER DETAILS FOR AIR SEALING NOTES (AIR BARRIER) SHEET METAL FLASHING WATER BARRIER SYSTEM SEALANT EXPANSION JOINT FILLER SIDEWALK/PAVING PER SITE PLANMIN2"SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:04 PMENV3.0 FOUNDATION DETAILS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 1 1/2" = 1'-0"1 TYPICAL FOOTING AT GRADE 1 1/2" = 1'-0"2 TYPICAL FOOTING AT PAVING 3" = 1'-0"3 TYPICAL BOTTOM OF WALL AT GRADE 3" = 1'-0"4 TYPICAL BOTTOM OF WALL AT PAVING EXTERIORINTERIOR DOOR PER ARCHITECTURAL (AIR BARRIER) THRESHOLD SET IN (2) CONTINUOUS BEADS OF SEALANT (AIR BARRIER) SWEEP (AIR BARRIER) FLOOR FINISH PER ARCHITECTURAL EXPANSION JOINT FILLER SIDEWALK/PAVING PER SITE PLAN UNDER SLAB VAPOR BARRIER, TAPE ALL PENETRATIONS AND PERIMETER PER MANUFACTURER TYPICAL DETAILS EXTERIORINTERIOR BACKER ROD AND SEALANT WATER BARRIER SYSTEM FLEXIBLE FLASHING DOOR AND FRAME PER ARCHITECTURAL (AIR BARRIER) BACKER ROD AND SEALANT (AIR BARRIER) EXTERIORINTERIOR BACKER ROD AND SEALANT SELF-ADHERED MEMBRANE DOOR AND FRAME PER ARCHITECTURAL (AIR BARRIER) BACKER ROD AND SEALANT (AIR BARRIER) WATER BARRIER SYSTEM SHEET METAL HEAD FLASHING WITH END DAMS R-10 RIGID INSULATION AT HEADER EXTERIORINTERIOR FLOOR FINISH PER ARCHITECTURAL SHEET METAL SILL PAN WITH BACK DAM AND END DAMS, SET IN CONTINUOUS BED OF SEALANT (AIR BARRIER) PEDESTRIAN TRAFFIC COATING2"COMPOSITE CONCRETE DECK WITH STEEL LEDGER PER STRUCTURAL WATER BARRIER SYSTEM SEALANT (AIR BARRIER) SLIDER DOOR PER ARCHITECTURAL (AIR BARRIER) EXTERIORINTERIOR FLOOR FINISH PER ARCHITECTURAL SHEET METAL SILL PAN WITH BACK DAM AND END DAMS, SET IN CONTINUOUS BED OF SEALANT (AIR BARRIER) DOOR PER ARCHITECTURAL (AIR BARRIER) THRESHOLD SET IN (2) CONTINUOUS BEADS OF SEALANT (AIR BARRIER) SWEEP (AIR BARRIER) WATER BARRIER SYSTEM COMPOSITE CONCRETE DECK WITH STEEL LEDGER PER STRUCTURAL EXTERIORINTERIOR FLEXIBLE FLASHING DOOR AND FRAME PER ARCHITECTURAL (AIR BARRIER) BACKER ROD AND SEALANT (AIR BARRIER) SEAL GWB TO JAMB FRAMING WITH CONTINUOUS BEAD OF SEALANT (AIR BARRIER) VINYL WINDOW PER ARCHITECTURAL (AIR BARRIER) CONTINUOUS BEAD OF SEALANT BACKER ROD AND SEALANT (AIR BARRIER) SHIM TRIM AS NEEDED TO LAY FLAT OVER WINDOW FLANGE BACKER ROD AND SEALANT EXTERIOR INTERIOR BACKER ROD AND SEALANT WATER BARRIER SYSTEM FLEXIBLE FLASHING DOOR AND FRAME PER ARCHITECTURAL (AIR BARRIER) BACKER ROD AND SEALANT (AIR BARRIER) CEDAR WOOD TRIM PER ARCHITECTURAL EXTERIORINTERIOR FLEXIBLE FLASHING CONTINUOUS BEAD OF SEALANT BACKER ROD AND SEALANT (AIR BARRIER) WATER BARRIER SYSTEM SEAL GWB TO JAMB FRAMING WITH CONTINUOUS BEAD OF SEALANT (AIR BARRIER) FLEXIBLE FLASHING SLIDER DOOR PER ARCHITECTURAL (AIR BARRIER) EXTERIORINTERIOR FLEXIBLE FLASHING CONTINUOUS BEAD OF SEALANT BACKER ROD AND SEALANT (AIR BARRIER) R-10 RIGID INSULATION AT HEADER WATER BARRIER SYSTEM SHEET METAL HEAD FLASHING WITH END DAMS SEAL GWB TO HEAD FRAMING WITH CONTINUOUS BEAD OF SEALANT (AIR BARRIER) FLEXIBLE FLASHING SLIDER DOOR PER ARCHITECTURAL (AIR BARRIER) SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:04 PMENV4.0 DOOR DETAILS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 3" = 1'-0"1 DOOR THRESHOLD AT SLAB ON GRADE 3" = 1'-0"2 DOOR JAMB AT LAP SIDING 3" = 1'-0"3 DOOR HEAD AT LAP SIDING 3" = 1'-0"4 SLIDER DOOR THRESHOLD AT DECK 3" = 1'-0"7 DOOR THRESHOLD AT BREEZEWAY 3" = 1'-0"8 DOOR JAMB AT WINDOW 3" = 1'-0"9 DOOR JAMB AT CORNER 3" = 1'-0"5 SLIDER DOOR JAMB AT LAP SIDING 3" = 1'-0"6 SLIDER DOOR HEAD AT LAP SIDING EXTERIORINTERIOR WATER BARRIER SYSTEM SELF-ADHERED MEMBRANE (AIR BARRIER) SHIM PER WINDOW MANUFACTURER REQUIREMENTS 1/8" THICK SOLID PLASTIC SHIM SET IN DAB OF SEALANT AT EACH FASTENER AT SILL VINYL WINDOW PER ARCHITECTURAL (AIR BARRIER) SHIM TRIM AS NEEDED TO LAY FLAT OVER WINDOW FLANGE SEAL GWB TO SILL FRAMING WITH CONTINUOUS BEAD OF SEALANT (AIR BARRIER) BACKER ROD AND SEALANT (AIR BARRIER) EXTERIORINTERIOR FLEXIBLE FLASHING CONTINUOUS BEAD OF SEALANT BACKER ROD AND SEALANT (AIR BARRIER) VINYL WINDOW PER ARCHITECTURAL (AIR BARRIER) WATER BARRIER SYSTEM SEAL GWB TO JAMB FRAMING WITH CONTINUOUS BEAD OF SEALANT (AIR BARRIER) FLEXIBLE FLASHING EXTERIORINTERIOR FLEXIBLE FLASHING CONTINUOUS BEAD OF SEALANT BACKER ROD AND SEALANT (AIR BARRIER) VINYL WINDOW PER ARCHITECTURAL (AIR BARRIER) R-10 RIGID INSULATION AT HEADER WATER BARRIER SYSTEM SHEET METAL HEAD FLASHING WITH END DAMS SEAL GWB TO HEAD FRAMING WITH CONTINUOUS BEAD OF SEALANT (AIR BARRIER) FLEXIBLE FLASHING EXTERIORINTERIOR DRAINABLE WATER BARRIER SYSTEM SELF-ADHERED MEMBRANE (AIR BARRIER) SHIM PER WINDOW MANUFACTURER REQUIREMENTS 1/8" THICK SOLID PLASTIC SHIM SET IN DAB OF SEALANT AT EACH FASTENER AT SILL VINYL WINDOW PER ARCHITECTURAL (AIR BARRIER) SEAL GWB TO SILL FRAMING WITH CONTINUOUS BEAD OF SEALANT (AIR BARRIER) BACKER ROD AND SEALANT (AIR BARRIER) EXTERIORINTERIOR FLEXIBLE FLASHING CONTINUOUS BEAD OF SEALANT BACKER ROD AND SEALANT (AIR BARRIER) VINYL WINDOW PER ARCHITECTURAL (AIR BARRIER) DRAINABLE WATER BARRIER SYSTEM SEAL GWB TO JAMB FRAMING WITH CONTINUOUS BEAD OF SEALANT (AIR BARRIER) FLEXIBLE FLASHING EXTERIORINTERIOR FLEXIBLE FLASHING CONTINUOUS BEAD OF SEALANT BACKER ROD AND SEALANT (AIR BARRIER) VINYL WINDOW PER ARCHITECTURAL (AIR BARRIER) R-10 RIGID INSULATION AT HEADER DRAINABLE WATER BARRIER SYSTEM SHEET METAL HEAD FLASHING WITH END DAMS SEAL GWB TO HEAD FRAMING WITH CONTINUOUS BEAD OF SEALANT (AIR BARRIER) FLEXIBLE FLASHING SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:04 PMENV4.1 WINDOW DETAILS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 3" = 1'-0"1 TYPICAL WINDOW SILL 3" = 1'-0"2 TYPICAL WINDOW JAMB 3" = 1'-0"3 TYPICAL WINDOW HEAD 3" = 1'-0"4 WINDOW SILL AT BOARD AND BATT 3" = 1'-0"5 WINDOW JAMB AT BOARD AND BATT 3" = 1'-0"6 WINDOW HEAD AT BOARD AND BATT TYVEK COMMERCIALWRAP APRON WINDOW ROUGH OPENING REFER TO DUPONT INSTALLATION GUIDELINES/INSTRUCTIONS FOR ADDITIONAL INSTALLATION REQUIREMENTS. STEP 1 STEP 2STEP 5 STEP 6 -INTERIOR VIEW STEP 7 STEP 8 CONTINUOUS BEAD OF DOW 758 SEALANT, THREE SIDES VINYL WINDOW SET PLUMB AND LEVEL IN FRESH SEALANT. FASTEN PER MANUFACTURER'S RECOMMENDATIONS. INSTALL CONTINUOUS BACKER ROD AND SEALANT ALL FOUR SIDES (AIR BARRIER) INSTALL 4" STRAIGHTFLASH AT JAMBS. ROLL DOWN TIGHT TO ACHIEVE PROPER ADHESION USING A 2-HANDED ROLLER AND HEAVY PRESSURE INSTALL 4" STRAIGHTFLASH AT HEAD. EXTEND BEYOND OUTER EDGES OF JAMB FLASHINGS. ROLL DOWN TIGHT TO ACHIEVE PROPER ADHESION USING A 2-HANDED ROLLER AND HEAVY PRESSURE 1" MIN1" MIN STEP 3 STEP 4 INSTALL 9" FLEXWRAP NF AT SILL. ROLL DOWN TIGHT TO ACHIEVE PROPER ADHESION USING A 2- HANDED ROLLER AND HEAVY PRESSURE6" MIN3" TYP COMMERCIALWRAP APRON 1" MINPROVIDE 1/8" THICK SOLID PLASTIC SHIMS SET IN DAB OF SEALANT AT EACH FASTENER AT SILL 10" MIN 12" MIMPLASTIC SHIMS SPACED PER WINDOW MANUFACTURER REQUIREMENTS STEP 9 INSTALL TYVEK COMMERCIALWRAP IN FIELD, LAPPING UNDER APRON AT SILL. CUT 1" FROM JAMBS AND HEAD TO EXPOSE WINDOW. DO NOT CUT THROUGH STRAIGHTFLASH OR APRON. STEP 10 INSTALL 4" STRAIGHTFLASH AT JAMBS AND HEAD. ROLL DOWN TIGHT TO ACHIEVE PROPER ADHESION USING A 2- HANDED ROLLER AND HEAVY PRESSURE SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:05 PMENV4.5 FENESTRATION FLASHING SEQUENCING DETAIL PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 1 1/2" = 1'-0"1 FLANGED WINDOW WRAP SEQUENCING DETAIL (WINDOW INSTALLED BEFORE WRB) REFER TO DUPONT INSTALLATION GUIDELINES/INSTRUCTIONS FOR ADDITIONAL INSTALLATION REQUIREMENTS. STEP 1 STEP 2 STEP 3 STEP 4 DOOR ROUGH OPENING BED OF SEALANT WRAP 9" STRAIGHTFLASH INTO ROUGH OPENING AT JAMBS ENTIRE HEIGHT OF JAMB. ROLL DOWN TIGHT TO ACHIEVE PROPER ADHESION USING A 2-HANDED ROLLER AND HEAVY PRESSURE FULLY WELDED PRE-FINISHED SHEET METAL SILL PAN FLASHING WITH END DAMS AND BACK DAM, SET IN FRESH SEALANT AND FASTEN AT END DAMS. INSTALL OVER TOP OF STEEL LINTEL NOTE:FOR SLAB ON GRADE CONDITION START AT STEP 3 INSTALL 9" FLEXWRAP NF AT HEAD. ROLL DOWN TIGHT TO ACHIEVE PROPER ADHESION USING A 2- HANDED ROLLER AND HEAVY PRESSURE4"MINSTEP 5 INSTALL PEDESTRIAN TRAFFIC COATING AT DECKS BEFORE INSTALLING DOOR THRESHOLD INSTALL DOOR AND FRAME PLUMB AND TRUE PER MANUFACTURER INSTALLATION INSTRUCTIONS. SET THRESHOLD IN (2) CONTINUOUS BEADS OF FRESH SEALANT INSTALL BACKER ROD AND SEALANT AT HEAD AND JAMBS, INTERIOR AND EXTERIOR INSTALL TYVEK COMMERCIALWRAP IN FIELD. CUT 1" FROM JAMBS AND HEAD TO EXPOSE DOOR. DO NOT CUT THROUGH STRAIGHTFLASH. LAP TYVEK COMMERCIALWRAP OVER BOTTOM OF WALL FLASHING STEP 6 STEP 7 INSTALL 4" STRAIGHTFLASH AT JAMBS AND HEAD. ROLL DOWN TIGHT TO ACHIEVE PROPER ADHESION USING A 2- HANDED ROLLER AND HEAVY PRESSURE SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:05 PMENV4.6 FENESTRATION FLASHING SEQUENCING DETAIL PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 1 1/2" = 1'-0"1 DOOR FLASHING SEQUENCING DETAIL EXTERIORINTERIOR SEAL WALL GYPSUM BOARD TO STEMWALL WITH CONTINUOUS SEALANT (AIR BARRIER) SEAL ALL PENETRATIONS AND PERIMETER OF INTERIOR GYPSUM WITH SPRAY FOAM OR SEALANT (AIR BARRIER) CONCRETE STEMWALL PER STRUCTURAL (AIR BARRIER) RESILIENT CHANNELS (WHERE OCCUR) SEAL WALL GYPSUM BOARD TO FLOOR SHEATHING WITH CONTINUOUS BEAD OF SEALANT (AIR BARRIER) SEAL CEILING GYPSUM BOARD TO WALL GYPSUM BOARD WITH CONTINUOUS SEALANT (AIR BARRIER) SEAL ALL PENETRATIONS AND PERIMETER OF INTERIOR GYPSUM WITH SPRAY FOAM OR SEALANT (AIR BARRIER) SEAL ALL GAPS/PENETRATIONS IN TOP PLATE WITH SEALANT OR SPRAY FOAM (AIR BARRIER) SEAL CEILING GYPSUM BOARD TO TOP PLATE WITH CONTINUOUS BEAD OF SEALANT BOTH SIDES OF WALL (AIR BARRIER) SEAL CEILING GYPSUM BOARD TO WALL GYPSUM BOARD WITH CONTINUOUS SEALANT BOTH SIDES OF WALL (AIR BARRIER) SEAL WALL GYPSUM BOARD TO FLOOR SHEATHING WITH CONTINUOUS BEAD OF SEALANT BOTH SIDES OF WALL (AIR BARRIER) SEAL WALL GYPSUM BOARD TO SLAB ON GRADE WITH CONTINUOUS SEALANT (AIR BARRIER) SEAL ALL PENETRATIONS AND PERIMETER OF INTERIOR GYPSUM WITH SPRAY FOAM OR SEALANT, BOTH SIDES OF WALL (AIR BARRIER) CONCRETE STEMWALL PER STRUCTURAL (AIR BARRIER) SEAL CEILING GYPSUM BOARD TO WALL GYPSUM BOARD WITH CONTINUOUS SEALANT (AIR BARRIER) SEAL CEILING GYPSUM BOARD TO WALL GYPSUM BOARD WITH CONTINUOUS SEALANT BOTH SIDES OF WALL (AIR BARRIER) SEAL ALL GAPS/PENETRATIONS IN STUD WITH SEALANT OR SPRAY FOAM. SEAL TOP AND BOTTOM OF STUD TO TOP AND BOTTOM PLATES (AIR BARRIER) SEAL WALL GYPSUM BOARD TO STUD WITH CONTINUOUS BEAD OF SEALANT BOTH SIDES OF WALL (AIR BARRIER) SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:05 PMENV5.0 TYPICAL AIR BARRIER DETAILS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI AIR BARRIER NOTES 1. DETAILS ON THIS SHEET ARE TYPICAL AND SHOULD BE APPLIED TO ALL ASSEMBLIES THAT ARE A PART OF THE THERMAL ENVELOPE OR DEMISING WALLS AND FLOOR/CEILINGS. EACH UNIT SHALL BE AIR SEALED INDEPENDENTLY TO PREVENT AIR LEAKAGE ACROSS UNITS. 2. ALL MATERIALS SHOWN IN RED ON THIS SHEET ARE COMPONENTS OF THE AIR BARRIER SYSTEM AND SHALL BE INSTALLED CONTINUOUSLY 3. SEAL ALL PENETRATIONS, JOINTS, AND PERIMETER OF INTERIOR GYPSUM BOARD THAT IS SHOWN IN RED ON THIS SHEET WITH SPRAY FOAM OR SEALANT. 4. ALL JUNCTION BOXES AND RECESSED LIGHTING THAT PENETRATE THE INTERIOR GYPSUM BOARD THAT IS SHOWN IN RED ON THIS SHEET SHALL BE RATED FOR AIR LEAKAGE OR FULLY SEALED WITH SEALANT, GASKETS, OR SPRAY FOAM TO PREVENT AIR LEAKAGE FROM THE UNIT ITSELF AND BETWEEN THE UNIT AND GYPSUM BOARD. 3" = 1'-0"1 EXTERIOR WALL AT SLAB ON GRADE 3" = 1'-0"2 EXTERIOR WALL AT FRAMED FLOOR 3" = 1'-0"3 INTERIOR WALL AT CEILING 3" = 1'-0"4 PARTY WALL AT FRAMED FLOOR 3" = 1'-0"5 PARTY WALL AT SLAB ON GRADE 3" = 1'-0"6 EXTERIOR WALL AT ROOF 3" = 1'-0"7 PARTY WALL AT ROOF 3" = 1'-0"8 INTERIOR WALL AT EXTERIOR WALL (PLAN VIEW) EXTERIORINTERIOR 1'-0"1'-0"WATER BARRIER SYSTEM, LAP 12" MIN EACH SIDE OF CORNER CEDAR TRIM PER ARCHITECTURAL EXTERIORINTERIOR WATER BARRIER SYSTEM, LAP 12" MIN EACH SIDE OF CORNER CEDAR WOOD TRIM PER ARCHITECTURAL 1'-0"1'-0" WATER BARRIER SYSTEM, LAP 12" MIN EACH SIDE OF WALL 1'-0"1'-0"CEDAR TRIM PER ARCHITECTURAL EXTERIORINTERIOR SHEET METAL FLASHING WATER BARRIER SYSTEM WATER BARRIER SYSTEM CEDAR BELLY BAND PER ARCHITECTURAL TOP OF BELLY BAND FFE PER ARCH SEE TYPICAL AIR BARRIER DETAILS FOR AIR SEALING NOTES (AIR BARRIER) EXTERIORINTERIOR WATER BARRIER SYSTEM CONTINUOUS VENT STRIP CEDAR TRIM PER ARCHITECTURAL SEE TYPICAL AIR BARRIER DETAILS FOR AIR SEALING NOTES (AIR BARRIER) SOFFIT PER ARCHITECTURAL EXTERIORINTERIOR CEDAR TRIM PER ARCHITECTURAL WATER BARRIER SYSTEM CONTINUOUS VENT STRIP SOFFIT PER ARCHITECTURAL ASPHALT SHINGLES OVER UNDERLAYMENT VENTING PER ARCHITECTURAL EXTERIORINTERIOR CEDAR TRIM PER ARCHITECTURAL WATER BARRIER SYSTEM ASPHALT SHINGLES OVER UNDERLAYMENT EXTERIORINTERIOR CEDAR TRIM PER ARCHITECTURAL WATER BARRIER SYSTEM VENTING PER ARCHITECTURAL BAFFLE PER ARCHTECTURAL SEE TYPICAL AIR BARRIER DETAILS FOR AIR SEALING NOTES (AIR BARRIER) EXTERIORINTERIOR CEDAR TRIM PER ARCHITECTURAL DRAINABLE WATER BARRIER SYSTEM ASPHALT SHINGLES OVER UNDERLAYMENT EXTERIORINTERIOR SHEET METAL FLASHING WATER BARRIER SYSTEM DRAINABLE WATER BARRIER SYSTEM CEDAR BELLY BAND PER ARCHITECTURAL TOP OF BELLY BAND TOP PLATE ELEV PER ARCH SEE TYPICAL AIR BARRIER DETAILS FOR AIR SEALING NOTES (AIR BARRIER) EXTERIORINTERIOR 1'-0"1'-0"DRAINABLE WATER BARRIER SYSTEM, LAP 12" MIN EACH SIDE OF CORNER CEDAR TRIM PER ARCHITECTURAL EXTERIORINTERIOR DRAINABLE WATER BARRIER SYSTEM, LAP OVER WATER BARRIER SYSTEM AT CORNER CEDAR WOOD TRIM PER ARCHITECTURAL1'-0"1'-0" WATER BARRIER SYSTEM BOARD AND BATT SIDING PER ARCHITECTURAL SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:06 PMENV5.1 WALL PENETRATIONS AND CLADDING DETAILS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 3" = 1'-0"1 OUTSIDE CORNER AT LAP SIDING 3" = 1'-0"2 INSIDE CORNER AT LAP SIDING 3" = 1'-0"3 END WALL 3" = 1'-0"7 BELLY BAND 3" = 1'-0"9 TOP OF WALL AT DECK 3" = 1'-0"8 TOP OF WALL AT HIGH EAVE 3" = 1'-0"11 TOP OF WALL AT GABLE 3" = 1'-0"12 TOP OF WALL AT EAVE 3" = 1'-0"10 TOP OF WALL AT BOARD AND BATT SIDING 3" = 1'-0"6 BELLY BAND AT BOARD AND BATT SIDING 3" = 1'-0"4 OUTSIDE CORNER AT BOARD AND BATT SIDING 3" = 1'-0"5 INSIDE CORNER AT BOARD AND BATT TO LAP SIDING AIR AND WATER BARRIER CUT AROUND PENETRATION. NO SEAMS IN AIR AND WATER BARRIER SYSTEM AT PENETRATION. STEP 1 INSTALL QUICKFLASH OR SHEET METAL VENT BOX AROUND PENETRATION, SET IN CONTINUOUS BEAD OF FRESH DOW 758 SEALANT STEP 2 INSTALL 4" STRAIGHTFLASH AT SIDES AND TOP. ROLL DOWN TIGHT TO ACHIEVE PROPER ADHESION USING A 2-HANDED ROLLER AND HEAVY PRESSURE STEP 3 AIR AND WATER BARRIER OVER TOP FLANGE OF QUICKFLASH OR SHEET METAL VENT BOX AND SEALED PER MANUFACTURER RECOMMENDATIONS STEP 4 GUARDRAIL ATTACHMENT PER MANUFACTURER. PREDRILL HOLES AND FILL WILL SEALANT BEFORE INSTALLING FASTENERS EXTERIORINTERIOR MOUNTING BLOCK PER ARCHITECTURAL WATER BARRIER SYSTEM FLEXIBLE FLASHING TARGET BEHIND MOUNTING BLOCK QUICKFLASH PRODUCT TO FIT PENETRATION WATER BARRIER SYSTEM EXTERIOR JUNCTION BOX LIGHT FIXTURE EXTERIORINTERIOR MOUNTING BLOCK PER ARCHITECTURAL FLEXIBLE FLASHING PER TYPICAL PENETRATION FLASHING SHEET METAL FLASHING DOWNSPOUT STRAP AT TOP AND BOTTOM AND 8' OC EXTERIORINTERIOR MOUNTING BLOCK PER ARCHITECTURAL WATER BARRIER SYSTEM FLEXIBLE FLASHING TARGET BEHIND MOUNTING BLOCK QUICKFLASH PRODUCT TO FIT PENETRATION WATER BARRIER SYSTEM VENT DUCT VENT HOOD EXTERIORINTERIOR MOUNTING BLOCK PER ARCHITECTURAL SHEET METAL FLASHING FLEXIBLE FLASHING PER TYPICAL PENETRATION FLASHING QUICKFLASH PRODUCT TO FIT PENETRATION WATER BARRIER SYSTEM HOSE BIB EXTERIORINTERIOR MOUNTING BLOCK PER ARCHITECTURAL SHEET METAL FLASHING FLEXIBLE FLASHING PER TYPICAL PENETRATION FLASHING CEDAR TRIM PER ARCHITECTURAL CONTINUOUS VENT STRIP SHEET METAL FLASHING SHEET METAL FLASHING WATER BARRIER SYSTEM SOFFIT PER ARCHITECTURAL EXTERIORINTERIOR CEDAR TRIM PER ARCHITECTURAL CONTINUOUS VENT STRIP SHEET METAL FLASHING SHEET METAL FLASHING WATER BARRIER SYSTEM SOFFIT PER ARCHITECTURAL EXTERIORINTERIOR WATER BARRIER SYSTEM SHEET METAL FLASHING CEDAR TRIM PER ARCHITECTURAL CONTINUOUS VENT STRIP SHEET METAL FLASHING SOFFIT PER ARCHITECTURAL BEAM PER STRUCTURAL SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:06 PMENV5.2 WALL PENETRATIONS AND CLADDING DETAILS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 3" = 1'-0"10 TYPICAL PENETRATION FLASHING 3" = 1'-0"9 TYPICAL GUARDRAIL ATTACHMENT 3" = 1'-0"5 TYPICAL LIGHT FIXTURE 3" = 1'-0"6 TYPICAL DOWNSPOUT STRAP 3" = 1'-0"7 TYPICAL VENT HOOD 3" = 1'-0"8 TYPICAL HOSE BIB PENETRATION 3" = 1'-0"1 ENTRY AWNING 3" = 1'-0"2 ENTRY AWNING 3" = 1'-0"3 BEAM AT DECK xvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxxvxEXTERIORINTERIOR SEALANT EXPANSION JOINT FILLER SIDEWALK/PAVING PER SITE PLAN WATER BARRIER SYSTEM SHEET METAL FLASHING DRAINAGE MAT POST FOUNDATION PER STRUCTURAL PPT POST PER STRUCTURAL SEALANT SELF-ADHERED MEMBRANE CONCRETE CAP PER ARCHITECTURAL FLEXIBLE FLASHING CEDAR TRIM PER ARCHITECTURAL BEVELED CEDAR CAP PER ARCHITECTURAL WATER BARRIER SYSTEM SHEET METAL FLASHING WITH WATERTIGHT SEAMS, LAPPED AND FULLY SOLDERED3" MIN6 " M I N 4" MIN 4" MIN4 " M I N SHINGLE LAP SADDLEFLASHING WITH WATER BARRIER SYSTEM NOTE:INSTALL FLEXIBLE FLASHING AT TOP OF WALL OVER SADDLEFLASHING. ENSURE PROPER ADHESION TO SHEET METAL. SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:06 PMENV5.3 WALL PENETRATIONS AND CLADDING DETAILS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 3" = 1'-0"4 COLUMN BASE 3" = 1'-0"1 TOP OF WALL 3" = 1'-0"2 SADDLEFLASHING AT TOP OF WALL COMPOSITE CONCRETE DECK PER STRUCTURAL BEAM PER STRUCTURAL PEDESTRIAN TRAFFIC COATING SHEET METAL CAP FLASHING 4"SLOPESLOPE PRE-FABRICATED GUARDRAIL ATTACHMENT PER MANUFACTURER CEDAR TRIM PER ARCHITECTURAL WATER BARRIER SYSTEM SHEET METAL CAP FLASHING COMPOSITE CONCRETE DECK PER STRUCTURAL BEAM PER STRUCTURAL PEDESTRIAN TRAFFIC COATING SLOPESLOPE COMPOSITE CONCRETE DECK PER STRUCTURAL BEAM PER STRUCTURAL SLOPESLOPE 4"SHEET METAL CAP FLASHING STEP 1 SHEET METAL FLASHING WITH WATERTIGHT SEAMS, LAPPED AND FULLY SOLDERED SEAL FLASHING TO CONCRETE DECK WITH CONTINOUS BEAD OF SEALANT 4" MIN 3" MIN4 " M I N STEP 2 WALL FLASHING PER DETAIL 6/ENV5.1 SEAL FLASHINGS WITH CONTINOUS BEAD OF SEALANT INSTALL PEDESTRIAN TRAFFIC COATING OVER FLASHINGS 4" MIN EXTERIORINTERIOR PEDESTRIAN TRAFFIC COATING COMPOSITE CONCRETE DECK WITH STEEL LEDGER PER STRUCTURAL WATER BARRIER SYSTEM SEE TYPICAL AIR BARRIER DETAILS FOR AIR SEALING NOTES (AIR BARRIER)2"6" MINSHEET METAL FLASHING WATER BARRIER SYSTEM SHEET METAL FLASHING, FASTEN PER TRAFFIC COATING MANUFACTURER REQUIREMENTS STEP 1 SHEET METAL FLASHING WITH WATERTIGHT SEAMS, LAPPED AND FULLY SOLDERED SEAL FLASHING TO CONCRETE DECK WITH CONTINOUS BEAD OF SEALANT DRIP EDGE FLASHING PER DETAIL 1 THIS SHEET 4" MIN 3" MIN4 " M I N STEP 2 WALL FLASHING PER DETAIL 6/ENV5.1 SEAL FLASHINGS WITH CONTINOUS BEAD OF SEALANT INSTALL PEDESTRIAN TRAFFIC COATING OVER FLASHINGS 4" MIN4 " M I N EXTERIORINTERIOR COMPOSITE CONCRETE DECK WITH STEEL LEDGER PER STRUCTURAL WATER BARRIER SYSTEM SEE TYPICAL AIR BARRIER DETAILS FOR AIR SEALING NOTES (AIR BARRIER) SHEET METAL FLASHING WATER BARRIER SYSTEM SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:07 PMENV6.0 DECK DETAILS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 3" = 1'-0"1 DECK EDGE 3" = 1'-0"2 STAIR LANDING EDGE 3" = 1'-0"3 BREEZEWAY EDGE 3" = 1'-0"4 STAIR LANDING FLASHING AT WALL 3" = 1'-0"6 DECK AT WALL 3" = 1'-0"7 DECK FLASHING AT OUTSIDE CORNER 3" = 1'-0"9 BREEZEWAY AT WALL RIDGE SHINGLES UNDERLAYMENT 1" RIDGE VENT ENSURE PROPER OPENING IN SHEATHING AT RIDGE FOR VENTING EXTERIORINTERIOR 6"ASPHALT SHINGLES 8" UNDERLAYMENT SHEET METAL FLASHING WITH HEMMED EDGE WATER BARRIER SYSTEM 2"1" 1/2" MIN HEAD WALL VENT 4" SHEET METAL STEP FLASHING UNDERLAYMENT ASPHALT SHINGLES WATER BARRIER SYSTEM 6"EXTERIORINTERIOR GUTTER PER ARCHITECTURAL OUTLET SCUPPER WITH STRAINER DOWNSPOUT PER ARCHITECTURAL CEDAR FASCIA PER ARCHITECTURAL ASPHALT SHINGLES OVER UNDERLAYMENT SHEET METAL DRIP EDGE FLASHING 1" 4" 1" SHEET METAL DRIP EDGE FLASHING ASPHALT SHINGLES UNDERLAYMENT CEDAR FASCIA PER ARCHITECTURAL 4" SHEET METAL FLASHING CONTINUOUS VENT STRIP CEDAR FASCIA PER ARCHITECTURAL ASPHALT SHINGLES UNDERLAYMENT SOFFIT PER ARCHITECTURAL 5 " 1 '-0 " SELF-ADHERING UNDERLAYMENT, FULL ROLL CENTERED ON VALLEY SHEET METAL VALLEY FLASHING WITH 1" TALL RIB CENTERED OVER VALLEY PIPE BOOT SET IN ROOFING CEMENT CAULK STAINLESS STEEL CLAMP UNDERLAYMENT ROOF DRAIN ROUND CUT IN SINGLE PLY ROOFING, EXTEND 1" PAST CLAMPING RING CONNECT TO DOWNSPOUT PER MEP DRAIN STRAINER DRAIN BOWL TAPERED INSULATION INSTALL COMPATIBLE SEALANT BETWEEN DRAIN BOWL FLANGE AND ROOFING MEMBRANE SINGLE-PLY ROOFING SYSTEM SLOPE SLOPE SL O PESLOPE UNDERLAYMENT SLOPESLOPE EXTERIORINTERIOR WALL ASSEMBLY PER ARCHITECTURAL ROOF ASSEMBLY PER ARCHITECTURAL8"WATER BARRIER SYSTEM UNDERLAYMENT SINGLE PLY ROOFING MEMBRANE CONTINUOUS TERM BARMIN2"SHEET METAL FLASHING EXTERIORINTERIOR CEDAR TRIM PER ARCHITECTURAL WATER BARRIER SYSTEM SHEET METAL DRIP EDGE FLASHING ASPHALT SHINGLES UNDERLAYMENT VENTING PER ARCHITECTURAL BUG SCREEN FOR VENTING 1 1/2" CLR SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:07 PMENV7.0 ROOF DETAILS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI, AJL DMI 3" = 1'-0"1 RIDGE VENT 3" = 1'-0"2 ROOF TO WALL FLASHING 3" = 1'-0"3 STEP FLASHING 3" = 1'-0"4 GUTTER FLASHING 3" = 1'-0"5 RAKE FLASHING 3" = 1'-0"6 HIGH EAVE FLASHING 3" = 1'-0"7 VALLEY FLASHING 3" = 1'-0"8 PIPE PENETRATION AT SHINGLE ROOF 3" = 1'-0"9 ROOF DRAIN WELL - SECTION 3" = 1'-0"10 SINGLE PLY ROOF AT WALL 3" = 1'-0"11 SHINGLE ROOF AT MECHANICAL WELL SHEET METAL SADDLE FLASHING WITH WATERTIGHT SEAMS, LAPPED AND FULLY SOLDERED SHINGLE LAP SADDLEFLASHING WITH WATER BARRIER SYSTEM SET DRIP EDGE IN (2) ROWS OF SEALANT ON SADDLE FLASHING 4" M IN 3" MIN6" MIN 4 " M IN 8" MINDRIP EDGE AND GUTTER PER DETAIL 4/ENV7.0 NOTE:DIVERTER FLASHING AND ROOFING NOT SHOWN FOR CLARITY, INSTALL DIVERTER FLASHING THEN ROOFING OVER DRIP EDGE HOLD GUTTER OFF WALL 1" MIN, CONTINUE CLADDING BEHIND SHEET METAL SADDLE FLASHING WITH WATERTIGHT SEAMS, LAPPED AND FULLY SOLDERED SHINGLE LAP SADDLEFLASHING WITH WATER BARRIER SYSTEM DRIP EDGE NOTE:DIVERTER, STEP FLASHING, AND ROOFING NOT SHOWN FOR CLARITY 8" MIN3" MIN4 " M IN 4" M I N FASCIA 4" M I N SHEET METAL SADDLE FLASHING WITH WATERTIGHT SEAMS, LAPPED AND FULLY SOLDERED SHINGLE LAP SADDLE FLASHING WITH WATER BARRIER SYSTEM 3" MIN6" MIN 4 " M IN 4 " M IN8" MIN8" MNSINGLE PLY ROOFING MEMBRANE, CONTINUE UP ONTO HATCH CURB AND FASTEN PER MANUFACTURER REQUIRMENTS UNDERLAYMENT ROOF HATCH, ATTACH PER MANUFACTURER REQUIREMENTS SINGLE PLY ROOFING MEMBRANE, CONTINUOUS OVER CURB UNDERLAYMENT INSTALL SECOND LAYER OF ROOFING MEMBRANE OVER CURB SEAL 253.625.7090 NEXUSbec.com747 FAWCETT AVE, SUITE C, TACOMA, WA 98402IF SHEET MEASURES LESS THAN 24"X36", IT IS A REDUCED PRINT. REDUCE SCALE ACCORDINGLY SHEETREVISIONSSHEET TITLEPROJECTPROJECT NO. DATE © COPYRIGHT 2021 - NEXUS bec, INC ALL RIGHTS RESERVED DRAWN BY: REVIEWED BY:8/2/2023 1:34:08 PMENV7.1 ROOF DETAILS PERMIT SET 08.02.23 23106NX TAHOMA TERRA APARTMENTSPHASE II9955 TAHOMA BLVD SEYELM, WA 98597NEW APARTMENT COMPLEXDMI DMI 3" = 1'-0"7 GUTTER AT WALL 3" = 1'-0"10 GUTTER AT WALL 3" = 1'-0"4 HIGH EAVE AT WALL 3" = 1'-0"1 ROOF HATCH 3" = 1'-0"2 MECHANICAL CURB