Loading...
Tahoma Terra-II - Building H - WSEC Lighting Compliance Form Tahoma Terra 081823Administered by: ©2023 NEEA, All rights reserved Date: Aug 18, 2023 LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Project & Applicant Information Project Title Tahoma Terra Phase 2 - 2018 WSEC For Building Department Use: Project Address 9955 TAHOMA BOULEVARD SE YELM, WA 98597 Applicant Name Office HBHU Applicant Phone 253-383-3257 Applicant Email wanrec@hultzbhu.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy Mixed Occupancy - Commercial + Group R building 3 stories or less General Building Use Type Multifamily/Residential Building Cond. Floor Area 11,230 General Project Types New Building New Building or Addition Lighting Scope Interior Lighting Exterior Lighting Alteration Lighting Scope Project Cond. Floor Area 11,230 Floors Above Grade 3 Compliance Method Compliance Method 1 - General Lighting Project Description HALF OF BUILDING IS 3-STORY APARTMENT, HALF OF BUILDING IS SINGLE STORY LEASING OFFICE Lighting Compliance Scope and Method Project Type Interior / Exterior (Interior includes both interior & parking)Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification New Building Interior Lighting Building area No Calculation Adjustments selected COMPLIES New Building Exterior Lighting Not applicable to exterior COMPLIES Additional Efficiency Options Included Project Title Tahoma Terra Phase 2 - 2018 WSEC Date Aug 18, 2023 Lighting Power Calculation NEW BUILDING - INTERIOR LIGHTING Compliance Verification COMPLIES Compliance Method Building area LPA Calculation Adjustment none Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF)LPA (Watts/SF)Total Watts Allowed (SF x LPA x 1) Total Proposed Watts By Building Area Compliance Status by Building Area Office 2,650 0.64 1,696 1,180 COMPLIES Proposed Lighting Power Density Fixture Type/Application Fixture ID Building Area New or Existing-to-Remain Quantity of Fixtures, CLDs or Luminaires (#F) Watts per Fixture, CLD or Luminaire (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Horizontal surface-mount F2 Office New 27 40 1,080 Horizontal surface-mount F1 Office New 4 25 100 Project Title Tahoma Terra Phase 2 - 2018 WSEC Date Aug 18, 2023 Proposed Fixtures Details NEW BUILDING - INTERIOR LIGHTING Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing-to-Remain Individual Fixtures Horizontal surface-mount F2 E-303, E-601 LED Office New Fixture Description: 4 FOOT CEILING WRAP Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary)Dimming method: Continuous dimming Do these fixtures require specific application lighting controls?: None required Horizontal surface-mount F1 E-303, E-601 LED Office New Fixture Description: ROUND SURFACE MOUNT CEILING PUCK Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Project Title Tahoma Terra Phase 2 - 2018 WSEC Date Aug 18, 2023 Lighting Power Calculation NEW BUILDING - EXTERIOR LIGHTING Compliance Verification COMPLIES Exterior Lighting Zone ZONE 2 Base Site Allowance 400 Exterior Tradable Lighting Power Allowance Tradable Surface Tradable Surface Sub-Type Surface Area (SF) LPA (Watts/SF) Linear Feet (LF) LPA (Watts/LF) Total Watts Allowed (LPA x SF) or (LPA x LF) Total Tradable Proposed Watts Tradable Compliance Status Building entrances and exits Pedestrian entrances & exits 400 14 5,600 Base Site Allowance 400 Totals 6,000 180 COMPLIES Proposed Tradable Lighting Power Density Fixture Type Fixture ID Tradable Surface Type Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Wall-mounted W1 Building entrances and exits - Pedestrian entrances & exits 6 30 180 Tradable Proposed Total 180