Loading...
Tahoma Terra Structural OFFICE plansetSTRUCTURAL NOTESS0 JOB #:23-5170 DATE:06-28-2023 REV: REV:DANIEL TYRRELL, P.E.CONSULTING ENGINEERAPPROVED BY: TYP. HANGER SCHEDULE 2x10 SIMPSON LUS210 (2)-2x10 SIMPSON LUS210-2 2x12 SIMPSON LUS210 (2)-2x10 SIMPSON LUS210-2 2x8 SIMPSON LUS28 (2)-2x8 SIMPSON LUS28-2 SIMPSON IUS1.81/9.5912" TJI 110 SIMPSON IUS2.06/9.5912" TJI 210 SIMPSON IUS1.81/11.881178" TJI 110 SIMPSON IUS2.06/11.881178" TJI 210 06-28-2023 MAILING: P.O. BOX 537, MILTON, WA 98354 PHONE: (253) 326-1081 EMAIL: DANTYRRELL@ATT.NETPLAN: TAHOMA TERRA - 2 SUITE OFFICECLIENT: THE KEIMIG ASSOCIATES HOLDOWN / STRAP SCHEDULE 24"x24"x10" CONC. PAD W/ (3)-#4 BARS EA. WAY 30"x30"x10" CONC. PAD W/ (4)-#4 BARS EA. WAY S1 JOB #:PLAN: TAHOMA TERRA - 2 SUITE OFFICEYELM, WATAHOMA BLVD SESYMBOL LEDGEND POST / COLUMN BRG WALL POINT LOAD ABOVE STANDARD STRUCTURAL FOUNDATION DETAILS SEE PAGE SD1 STANDARD STRUCTURAL FRAMING DETAILS SEE PAGE SD2 ANCHOR BOLT SCHEDULE DATE: REV: REV: (2)-16d @ 5" O.C. 16d @ 5" O.C. N/A (2)-16d @ 4" O.C. 8d @ 3" O.C. 8d @ 3" O.C. 8d @ 2" O.C. SHEARWALL SCHEDULE (HF STUDS @ 16" O.C.) 8d @ 6" O.C. 7/16 APA RATED SHEATHING OR APA RATED SIDING U.N.O. 16d @ 3-1/2" O.C.8d @ 4" O.C.A35 @ 14" O.C. A35 @ 10" O.C. A35 @ 8" O.C. A35 @ 7" O.C. A35 @ 21" O.C. NOTES: (NOT ALL NOTES APPLY TO ALL SHEARWALLS. SEE SCHEDULE FOR APPROPRIATE NOTES) 1. SCHEDULE IS BASED ON HEM-FIR STUDS @ 16" O.C. 2. PLYWOOD SHEATHING IS TO BE APA RATED 24/O MINIMUM AND MAY BE OSB OF EQUAL RATING. 3. ALL SHEATHING TO BE DIRECTLY APPLIED TO STUDS AND ALL EDGES BLOCKED. 4. ALL NAILS TO BE COMMON WIRE OR GALVANIZED BOX (HOT DIPPED OR TUMBLED ONLY) 5. STUDS TO BE 3x OR WIDER AT ADJOINING PANEL EDGES AS NOTED. IN LIEU OF A SINGLE 3x STUD, (2)-2x STUDS MAY BE FASTENED TOGETHER W/ CONSTRUCTION ADHESIVE & 10d NAILS. COMPLETELY COAT STUDS W/ ADHESIVE & SANDWICH TOGETHER W/ (2)-ROWS 10d NAILS @ 6" O.C. STAGGERED. SQUEEZE OUT OF ADHESIVE SHOULD BE EVIDENT. 6. SHEATHING PANEL JOINTS EACH SIDE OF WALL TO BE OFFSET OR, IF PANEL JOINTS ALIGNED, STUDS TO BE 3x OR WIDER AT ADJOINING PANEL EDGES AS NOTED. 7. N/A 8. SHEATHING NAILING SHOWN APPLIES TO ALL PANEL EDGES. SHEATHING NAILING AT INTERMEDIATE SUPPORT TO BE OF SAME SIZE SHOWN @ 12" O.C. CAUTION: DO NOT OVERDRIVE NAILS. NAIL HEADS TO BE FLUSH WITH FACE OF SHEATHING. 9. REFER TO TYPICAL DETAILS FOR LOCATIONS OF FRAMING ANCHORS WHEN REQ'D. (FRAMING ANCHOR NOT REQUIRED WHEN SHEATHING EXTENDS ONTO RIM ABOVE & BELOW SHEARWALL.) 10. WHEN SHEATHING EXTENDS ONTO RIM JOIST BELOW, SECURE BOTTOM PLATE W/ 16d NAILS @ 6" O.C. 8d @ 4" O.C.A35 @ 7" O.C. 1,2,3,4,8,9,10 1,2,3,4,5,8,9,10 1,2,3,4,5,8,9,10 1,2,3,4,5,8,9,10 1,2,3,4,6,8,9,10 1,2,3,4,5,8,9,10 JOIST / BEAM / HDR SCHEDULE JOIST / BEAM / HDR SIZEMARK DANIEL TYRRELL, P.E.CONSULTING ENGINEER MAILING: P.O. BOX 537, MILTON, WA 98354 PHONE: (253) 326-1081 EMAIL: DANTYRRELL@ATT.NETAPPROVED BY: (2)-16d @ 31 2" O.C. FOOTING SCHEDULE 06-28-2023 LSTHD8 3"HF 20-16d --CLIENT: THE KEIMIG ASSOCIATES23-5170 06-28-2023 STANDARD STRUCTURAL FOUNDATION DETAILSSD1 REV: REV:DANIEL TYRRELL, P.E.CONSULTING ENGINEER MAILING: P.O. BOX 537, MILTON, WA 98354 PHONE: (253) 326-1081 EMAIL: DANTYRRELL@ATT.NETAPPROVED BY: REV: REV:06-20-2016 01-17-2017 11-28-2017 06-28-2023 10-01-2021PLAN: TAHOMA TERRA - 2 SUITE OFFICECLIENT: THE KEIMIG ASSOCIATES STANDARD STRUCTURAL FRAMING DETAILS07-30-2015 SD2 REV: REV:DANIEL TYRRELL, P.E.CONSULTING ENGINEERAPPROVED BY: REV: REV: 08-20-2019 06-28-2023 MAILING: P.O. BOX 537, MILTON, WA 98354 PHONE: (253) 326-1081 EMAIL: DANTYRRELL@ATT.NETPLAN: TAHOMA TERRA - 2 SUITE OFFICECLIENT: THE KEIMIG ASSOCIATES