Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
WSEC Lighting Compliance Summary OFFICE
Administered by: ©2023 NEEA, All rights reserved Date: Aug 01, 2023 LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Project & Applicant Information Project Title TAHOMA TERRA HOLDINGS LLC 2 SUITE OFFICE - 2018 WSEC For Building Department Use: Project Address TOHOMA BOULEVARD YELM, WA 98597 Applicant Name Raul Garcia Applicant Phone 253-939-3232 Applicant Email raultkaarchitects@gmail.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Other Building Cond. Floor Area 1,428 General Project Types New Building New Building or Addition Lighting Scope Interior Lighting Exterior Lighting Alteration Lighting Scope Project Cond. Floor Area 1,428 Floors Above Grade 2 Compliance Method Compliance Method 1 - General Lighting Project Description 2- SUITE OFFICE BUILDING. ONE SUITE HAS A SECOND STORY. Lighting Compliance Scope and Method Project Type Interior / Exterior (Interior includes both interior & parking)Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification New Building Interior Lighting Building area No Calculation Adjustments selected COMPLIES New Building Exterior Lighting Not applicable to exterior COMPLIES Additional Efficiency Options Included Project Title TAHOMA TERRA HOLDINGS LLC 2 SUITE OFFICE - 2018 WSEC Date Aug 01, 2023 Lighting Power Calculation NEW BUILDING - INTERIOR LIGHTING Compliance Verification COMPLIES Compliance Method Building area LPA Calculation Adjustment none Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF)LPA (Watts/SF)Total Watts Allowed (SF x LPA x 1) Total Proposed Watts By Building Area Compliance Status by Building Area Office 1,428 0.64 914 416 COMPLIES Proposed Lighting Power Density Fixture Type/Application Fixture ID Building Area New or Existing-to-Remain Quantity of Fixtures, CLDs or Luminaires (#F) Watts per Fixture, CLD or Luminaire (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Recessed downlight LED DISK DOWNLIGHT Office New 30 13 390 Wall-mounted VANITY LIGHT Office New 2 13 26 Exempt Fixtures Emergency (off when unoccupied)EXIT SIGNS Office New 2 Emergency (off when unoccupied)EGRESS LIGHTS Office New 8 Project Title TAHOMA TERRA HOLDINGS LLC 2 SUITE OFFICE - 2018 WSEC Date Aug 01, 2023 Proposed Fixtures Details NEW BUILDING - INTERIOR LIGHTING Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area New or Existing-to-Remain Individual Fixtures Recessed downlight LED DISK DOWNLIGHT A-8.0 LED Office New Fixture Description:Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall-mounted VANITY LIGHT A-8.0 LED Office New Fixture Description:Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Exempt Fixtures Emergency (off when unoccupied)EXIT SIGNS A-2.2 Office New Fixture Description:Do these fixtures require specific application lighting controls?: Lighting for non-visual applications, independently controlled Emergency (off when unoccupied)EGRESS LIGHTS A-2.2 Office New Fixture Description:Do these fixtures require specific application lighting controls?: Lighting for non-visual applications, independently controlled Project Title TAHOMA TERRA HOLDINGS LLC 2 SUITE OFFICE - 2018 WSEC Date Aug 01, 2023 Lighting Power Calculation NEW BUILDING - EXTERIOR LIGHTING Compliance Verification COMPLIES Exterior Lighting Zone ZONE 2 Base Site Allowance 400 Exterior Tradable Lighting Power Allowance Tradable Surface Tradable Surface Sub-Type Surface Area (SF) LPA (Watts/SF) Linear Feet (LF) LPA (Watts/LF) Total Watts Allowed (LPA x SF) or (LPA x LF) Total Tradable Proposed Watts Tradable Compliance Status Building entrances and exits Pedestrian entrances & exits 52 14 728 Base Site Allowance 400 Totals 1,128 54 COMPLIES Proposed Tradable Lighting Power Density Fixture Type Fixture ID Tradable Surface Type Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Wall-mounted WALL SCONCE Building entrances and exits - Pedestrian entrances & exits 3 18 54 Tradable Proposed Total 54