Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
WSEC Envelope Compliance Summary RETAIL RESTAURANT-A
Administered by: ©2023 NEEA, All rights reserved Date: Aug 04, 2023 ENVELOPE COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Project & Applicant Information Project Title TAHOMA TERRA HOLDING LLC FOOD SERVICE BUILDING - 2018 WSEC For Building Department Use: Project Address TAHOMA BLVD Yelm, WA 98597 Applicant Name Raul Garcia Applicant Phone 253-939-3232 Applicant Email raultkaarchitects@gmail.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type(s)Dining, Restaurant Building Cond. Floor Area 4,240 Project Scope New Building Space Conditioning Categories Fully Conditioned Project Cond. Floor Area 4,240 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Envelope Project Description NEW CONSTRUCTION FOOD SERVICE BUILDING Envelope Compliance Scope and Method Scope Space Conditioning Category Compliance Method WWR/SRR per Category UA Calculation Adjustment Fenestration Alternates Compliance Verification New Building Fully Conditioned Component performance 12.68% / %None selected No alternates selected COMPLIES Air Barrier Testing Air barrier testing included in project scope Air Barrier Comments Project Title TAHOMA TERRA HOLDING LLC FOOD SERVICE BUILDING - 2018 WSEC Date Aug 04, 2023 Scope & Space Conditioning NEW BUILDING - FULLY CONDITIONED Compliance Verification COMPLIES Window-to-wall Ratio 12.68%Skylight-to-roof-ratio %Vertical Fenestration Alternate No alternates selected Opaque Envelope Assemblies Insulation R-Values Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) 2nd Layer (MB Roof)U-Factor Net Area (SF) Insulation entirely above deck A-4.0 ROOF Exterior R-38 (< 0.04%)U-0.027 4,240 U-Factor Source: WSEC Appendix A U-Factor Source Description: Is this assembly exterior or interior?: Exterior Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Wood-framed and other - Commercial A-4.1 WOOD FRAMING WALL Exterior R-21 R-0 (< 0.04%)U-0.054 6,708 Which insulation code target does wall comply with?: R-21 Cavity + Intermediate Framing U-Factor Source: WSEC Appendix A U-Factor Source Description:Wall Framing Type (Standard, Inter., Advanced): Intermediate Framing Depth: 2x6 Framing Spacing: 16" O.C. Is this assembly exterior or interior?: Exterior Slab-on-grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter Length (SF) Heated slab A-2.2 SLAB ON GRADE (HEATED)At grade level R-10 R-10 F-0.55 296 Slab Insulation Method: Fully insulated slab (slab edge and underneath)F-Factor Source: WSEC Appendix A F-Factor Source Description: Fenestration & Opaque Door Assemblies Insulation R-Values Opaque Doors Location in Documents Assembly ID Assembly Location Door Insulation U-Factor Rough Opening (SF) Swinging a-3.1 Service Door Exterior U-0.37 21 What percentage of this opaque door is glazing?: 50% or less U-Factor Source: WSEC Appendix A U-Factor Source Description:Is this assembly exterior or interior?: Exterior Is this a public entrance door?: No Vertical Fenestration Location in Documents Assembly ID Assembly Location Orientation Shading (PF)Fenestration SHGC Fenestration U-Factor Rough Opening (SF) Fixed - Class AW or site built A-3.0 Storefront Exterior South/East/West Facing PF < 0.2 SHGC-0.38 U-0.38 977 U-Factor & SHGC Source: NFRC Rating U-Factor Source Description: Is this assembly exterior or interior?: Exterior Project Title TAHOMA TERRA HOLDING LLC FOOD SERVICE BUILDING - 2018 WSEC Date Aug 04, 2023 U x A Calculation NEW BUILDING - FULLY CONDITIONED COMPLIES Opaque Envelope Assemblies PROPOSED TARGET Roof/Ceiling Assembly ID Roof/Ceiling Assembly U- Factor Net Area (SF)U x A Roof/Ceiling Assembly U- Factor Net Area (SF)U x A Insulation entirely above deck ROOF 0.027 4,239.5 114.5 0.027 4,239.5 (1)114.5 Walls Assembly ID Wall Assembly U- factor Net Area (SF)U x A Wall Assembly U- factor Net Area (SF)U x A Wood-framed and other - Commercial WOOD FRAMING WALL 0.054 6,707.5 362.2 0.054 6,707.5 (1)362.2 Slab on Grade Floors PROPOSED TARGET Slab-on-grade Floors Assembly ID F-Factor Perimeter Length (LF)U x A F-Factor Perimeter Length (LF)U x A Heated slab SLAB ON GRADE (HEATED)0.55 296.0 162.8 0.55 296.0 (1)162.8 Fenestration and Opaque Door Assemblies PROPOSED TARGET Opaque Doors Assembly ID Door Assembly U- Factor Rough Opening (SF)U x A Door Assembly U- Factor Rough Opening (SF)U x A Swinging Service Door 0.37 21.0 7.8 0.37 21.0 (1)7.8 Vertical Fenestration Assembly ID Fenestration Assembly U- Factor Rough Opening (SF)U x A Fenestration Assembly U- Factor Rough Opening (SF)U x A Fixed - Class AW or site built Storefront 0.38 977.4 371.4 0.38 977.4 (1)371.4 Proposed Area Proposed UxA Target Area Target UxA Project Totals 12,241 1,019 12,241 1,019 Project Title TAHOMA TERRA HOLDING LLC FOOD SERVICE BUILDING - 2018 WSEC Date Aug 04, 2023 SHGC x A Calculation NEW BUILDING - FULLY CONDITIONED COMPLIES Fenestration and Opaque Door Assemblies PROPOSED TARGET Vertical Fenestration - South/East/West Facing Assembly ID PF Fenestration SHGC Rough Opening (SF)SHGC x A Fenestration SHGC Rough Opening (SF)SHGC x A Fixed - Class AW or site built Storefront PF < 0.2 0.38 977.4 371.4 0.38 977.4 (1)371.4 Proposed Area Proposed SHGC x A Target Area Target SHGC x A Project Totals 977 371 977 371