Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
WSEC Lighting Compliance Summary RETAIL RESTAURANT-B
Administered by: ©2023 NEEA, All rights reserved Date: Aug 07, 2023 LIGHTING COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R1 Project & Applicant Information Project Title TAHOMA TERRA HOLDINGS LLC RETAIL OR FOOD SERVICE BUILDING - 2018 WSEC For Building Department Use: Project Address TOHMOA BOULEVARD TBD YELM, WA 98597 Applicant Name Raul Garcia Applicant Phone 253-939-3232 Applicant Email raultkaarchitects@gmail.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Retail, General Sales Building Cond. Floor Area 3,081 General Project Types New Building New Building or Addition Lighting Scope Interior Lighting Exterior Lighting Alteration Lighting Scope Project Cond. Floor Area 3,081 Floors Above Grade 1 Compliance Method Compliance Method 1 - General Lighting Project Description NEW CONSTRUCTION, 3 SUITES, RETAIL OR FOOD SERVICE BUILDING Lighting Compliance Scope and Method Project Type Interior / Exterior (Interior includes both interior & parking)Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification New Building Interior Lighting Space by space Reduced lighting power density option - 20%COMPLIES New Building Exterior Lighting Not applicable to exterior COMPLIES Additional Efficiency Options Included Project Title TAHOMA TERRA HOLDINGS LLC RETAIL OR FOOD SERVICE BUILDING - 2018 WSEC Date Aug 07, 2023 Lighting Power Calculation NEW BUILDING - INTERIOR LIGHTING Compliance Verification COMPLIES Compliance Method Space by space LPA Calculation Adjustment LPA x 0.8 Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Ceiling Height (Ft)Gross Interior Area (SF)LPA (Watts/SF)Total Watts Allowed (SF x LPA x 0.8) Total Proposed Watts (LPD + Display LPD)Compliance Status Corridors Service 253 0.41 104 Restroom General 175 0.63 110 Retail General sales 2,655 1.05 2,787 Proposed Total LPD 327 Totals Calculation Adjustment Applied - LPA x 0.8 2,401 327 COMPLIES Proposed Lighting Power Density Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Recessed downlight CAN LIGHT 32 9 288 Wall-mounted VANITY FIXTURE 3 13 39 Proposed Total LPD 327 Project Title TAHOMA TERRA HOLDINGS LLC RETAIL OR FOOD SERVICE BUILDING - 2018 WSEC Date Aug 07, 2023 Proposed Fixtures Details NEW BUILDING - INTERIOR LIGHTING Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing-to-Remain Individual Fixtures Recessed downlight CAN LIGHT A-8.0 LED New Fixture Description:Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall-mounted VANITY FIXTURE A-8.0 LED New Fixture Description:Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Project Title TAHOMA TERRA HOLDINGS LLC RETAIL OR FOOD SERVICE BUILDING - 2018 WSEC Date Aug 07, 2023 Lighting Power Calculation NEW BUILDING - EXTERIOR LIGHTING Compliance Verification COMPLIES Exterior Lighting Zone ZONE 3 Base Site Allowance 500 Exterior Tradable Lighting Power Allowance Tradable Surface Tradable Surface Sub-Type Surface Area (SF) LPA (Watts/SF) Linear Feet (LF) LPA (Watts/LF) Total Watts Allowed (LPA x SF) or (LPA x LF) Total Tradable Proposed Watts Tradable Compliance Status Building entrances and exits Entry canopies 4,810 0.40 1,924 Base Site Allowance 500 Totals 2,424 216 COMPLIES Proposed Tradable Lighting Power Density Fixture Type Fixture ID Tradable Surface Type Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Wall-mounted WALL SCONCE Building entrances and exits - Entry canopies 12 18 216 Tradable Proposed Total 216