Loading...
16301 greenbrier st se structurals calcsSTRUCTURAL CALCULATIONS For Mountain Terrace Builders 16301 GreenBrier St. SE, Yelm WA Residential Lateral and Vertical Design November 16, 2023 Project # 2023231 By PRECISE ENGINEERING INC. HAROLD HAHNENKRATT, P.E. li�IbI2�Z3 SCOPE: Provide structural calculations for lateral and vertical design per the 2018 IBC. House to be built at 16301 Greenbrier St. SE, Yelm WA LOADS AND MATERIALS Roof: Comp Roofing S.Opsf Pre-engineered Trusses @ 24" oc 2.9psf Roof Sheathing 1.5psf Insulation 1.2psf 5/8" GWB 2.8psf Misc. 1.5psf Dead Load = 14.9» 15psf Snow Load = 25psf Wall: Siding (Lap) 3.Opsf Sheathing 1.5psf 2x6 Studs @ 16"oc 1.7psf Insulation 0.75psf 1/z" GWB 2.2psf Misc 1.5psf_ Dead Load = 10.65>12psf Floor: I joists at 16"oc Dead Load = 12psf Part. Load = IOpsf Live Load = 40psf Wind: 110 MPH Exp. B Seismic: Site Class = D Design Category = D Use Group = I R = 6.5 Ca = 4 Wo = 3 Soil: = 1500 PSF, Assumed bearing capacity = 38 PCF, Assumed Active Fluid Pressure = 350 PCF, Assumed Passive fluid Pressure = 0.45, Assumed Coefficient of Friction = 110 PCF, Assumed Soil Density Lumber: 2x > 4x = #2DF 6x > _ #lDF GLB = 24f -v4 for simple span = 24f -v8 for cont. and cantilever. Concrete: f c = 2500psi Rebar = Grade 60 11/16/23,1:02 PM U.S. Seismic Design Maps USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error. USGS web services are now operational so this tool should work as expected. �OINEE„@ PD c®� CALIFOflNIp Z 16301 Greenbrier St SE, Yelm, WA 98597, USA Latitude, Longitude: 46.942569, -122.595065 1 creek to Laser Studio z Angela's Elite Grooming e Fart SteV6fis le Elementary School Map data 02023 I Date 11/16/2023, 1:01:40 PM i Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Stiff Soil Type Value Description Ss 1.285 MCER ground motion. (for 0.2 second period) S1 0.464 MCER ground motion. (for 1.0s period) i SMS 1.285 Site -modified spectral acceleration value SM1 null -See Section 11.4.8 Site -modified spectral acceleration value SDs 0.857 Numeric seismic design value at 0.2 second SA I SD1 null -See Section 11.4µ8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.504 MCEG peak ground acceleration E i FPGA 1.1 Site amplification factor at PGA PGAM 0.555 Site modified peak ground acceleration TL 16 Long -period transition period in seconds SsRT 1.285 Probabilistic risk -targeted ground motion. (0.2 second) SsUH 1.415 Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration 3 SsD 1.5 Factored deterministic acceleration value. (0.2 second) S1RT 0.464 Probabilistic risk -targeted ground motion. (1.0 second) S1 UH 0.52 Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration. S1 D 0.621 Factored deterministic acceleration value. (1.0 second) PGAd 0.504 Factored deterministic acceleration value. (Peak Ground Acceleration) https://www.seismicmaps.org 1/3 ps30 Pitch Roof Wall 2:12 -7.2 17.76 3:12 -6.5 19.65 4:12 -5.7 21.5 5:12 -0.5 21.4 6:12 6.87 20.3 >7:12 13.3 19.4 LATERAL DESIGN Wind Loading: ps=XKztPs30 ASD ps = .6 AKnPs30 Wind Speed Exposure Roof Pitch A= 1 Kn = 1 Simplified (ASCE 7-16 Chapter 28 Part 2) 110 mph B 5:12 ps30 = -0.5 (Roof) 21.4 (Wall) ASD PS = -0.3 (Roof) 12.8 (Wall) Ps= PS = Seismic Loading: Section 12.4,12.8ASCE7-16 Eh=rQh Qh=V V= CSW CS=SDs/1.4R E=(1.3SDs/1.4R)W SDs 0.857 Minimum Loading 8.0 (Roof) 16.0 (Wall) (ASD) Minimum Loading 4.8 (Roof) 9.6 (Wall) R = 6.5 (Wood Shear Wall) R = 1.5 (Cantilever Column) V= 0.122 Wt. (Wood Shear Wall) V= 0.531 Wt. (Cantilever Column) r=1.3 m 4-14 .q-,qi m r■� FL W m4m9 tLL LFm Lu �� d (D oXu� m g Z m � Z 9 I r ❑ g .9-,d $9�s W 1 ""Z 7j fl 36= Cil 8 cl oaf L q e� �y 0 x nla w a nm KA �c J Ia 10 m r■� FL Two Story Wind to Diaphragm Wind Upper Plate Height 8.1 Roof 4.8 Main Plate Height 9.1 Walls 12.8 Floor Depth 1 Dlaphragm Roof Ht. Wind Load Length Total Load 1-2 Roof 5.5 1.4 96.2 35.0 3365.6 Upper 0 122.9 38.0 4669.4 SUM 8035.0 Roof Ht. Wind Load Length Total Load A-8 Roof 0.5 3.8 102.2 28.0 2862.7 Upper 0 122.9 30.0 3686.4 5UM 6549.1 L � C�� vi 640 71 a c , 3 2 5 5 : 0 0 cc } 3 a 3 w E V-) g a c E E 'e \ \ \ \ � & 0 0 / 0 ƒW & f.S2 I _ —0 e c m > o® d o c a g o E a a & \ \ \ \ \ w co w w \ \ \ ƒ / 00, /P g (D & A \ C,6 \ � k CL > % \ \ \ \ o o R a s _ CO w # g m g » e r c a § 2 \ \ \ \ / 'L \ 0 2 5 ƒ 4 / \ \ \ \ / 0 0 0 0 c e o 0 6 3 % R a 0 \ \ m E�ao mo d \ / / \ \ / � \ \ \ 0 CL \ 9 I \ � co o % � \ � § \ 3 / I �/\ 0 \ c � » » N C) q \ .g g \ � \ R @ 9 9 r & \ @ 0 0 cc } 3 a 3 w E g 'e � / / r & @ I —0 e c m o® d w a s \ \ \ \ \ w co w w \ \ \ ƒ g � g < /P g (D & A \ C,6 \ / / > % CO o e o o R a s _ CO w # m » e r c 6 § 2 \ \ \ \ / / \ / 2 \ \ \ \ / c o 0 \o % 06 \ \ \ E�ao mo d \ / / \ � \ \ \ 0 \ 9 I \ � a� rn 00LO Ln o g O b O C p O N O N b Q Q Q o 0 1 rt co cr) m (.o m a Ln Ln o dt 00 0 Q 4 Q O co 4 cc C7 C7 Q Q Cm7� n Cmc 5 U7 E E U7 co 47 7 m 4, tr7 d 't m m coo N N r r {p Oco df d- co O co m dco r dco d N 0 0 r r co r r N 7 � D P co C* C7 C7 cp cD �f d' Y Y �- N Q CO J �' 9i W w 7a w YJ iJ W ro mo c�aa b+ 7+W i� 1tl �n nJ�v� � W rl eJ I 1 N Il II X N I ❑ H H H H HdF4 b sJ tl1 N rn y I � �1 I!I U x C]RR m iv 'd A M m C N m N 0 "'vvvv yvv�v v z r•i m b � u V O N O �.IN N m .ry NH OU p[] po x b+ 7+W v m NnIN m v W Aa � W rl eJ I 1 N Il II X N I ❑ H H H H HdF4 I sJ tl1 N rn y I °xxxx U NNM �1 I!I x C]RR A .. y C E9 N d N W N w - ' 0 a Ts r o a 00 HdF4 x C w '6 - ' ' w �c m r•i m IH m N m OU p[] po �° m � -Y � n 4 n ✓J OO m C1 H V H X01 � C1 �ryN H N N m W +A N � 3 a� � von oo po �a m t° S F .•i .a n N N •i u' I .q y� --I •q -i ri r rJ N H W .� � 00 tT m LA m tli x � N 1'' m wo u�cn d � a A u •1 m M +1 •' J � o ca -1 N o P n v M '~ 00 a � f•1 ' p d N v v H N v � 1 M a Y w ID a a w M H H a N FG Table 1. Recommended Allowable Design Values for APA Portal Frame Used on a Rigid -Base Minimum Width Maximum Height Allowable Design (ASD) Values per Frame Segment (in.) (ft) Shear[O) (Ibi) Deflection (in.) Load Factor 8 850 0.33 3.09 16 - 10 0.44 2.97 8 li7$ 0.38 2.88 24 10 1,125 0.51 3.42 Foundation for Wind or Seismic Lc adine".'Xds (a) Design values are based on The use of Douglas -fir or Southern pine framing. For other species of framing, multiply the above shear design value by the specific gravity adjustment factor = (1 - (0.5 - SG)), where SG = specific gravity of the actual framing- This adjustment shall not be greater than 1.0. (b) For construction as shown in Figure 1. (c) Values are for a single portal -frame segment (one verficol leg and o portion of the header)- For multiple portal -frame segments, the allowable shear design values are permitted to be multiplied by the number of frame segments (e.g., two = 2x, three = 3x, etc.). (d) interpolation of design values for heights between 8 and 10 feet, and for portal widths between 16 and 24 inches, is parm itted- (e) The allowable shear design value 1s permitted to be multiplied by a factor of 1-4 for wind design. (f) If story drift is not a design consideration, the tabulated design shear voIues ore permitted to be multiplied by a factor of 1.15. This factor is permit led to be used cumuIotivelywith the wind -design adjustment factor in Footnote (el above. Figure 1. Construction Details for APA Portal -Frame Design with Hold Downs Extent of header with double portal frames (two braced wall panels) Extent of header with single portal frame (one braced wall panels] 2' to 18' rough width of opening for single or double portal —f— ; �Y wail , height - Min foatin size under opening is 12" x 12'. A turned -down slab sholI �e permitted or door openings. Min (1 ) 518' diameter anchor bolt installed per IRC R403-1-6 - with 2' x 2' x 3116' plole washer Header to jock -stud strop per wind design min 1000 Ibf on both sides of opening opposite side of sheathing Fasten top plate to header with two rows of 16d sinker nails at 3' o.c- typ Min. 3/5' wood structural panel sheathing If needed, panel splice edges shall occur over and be noiled to common blocking within middle 24" of portal height. One raw of 3' a. c. nailing is required in each panel edge. Typical portal frame construction Klin double 2x4 post (king and jack studl. Number of jack studs per IRC tables R502.5(1) & (2). Min 1000 Ib hold-down device (embedded into concrete and nailed into framing) 2 Q 2014 APA -The Fnktrce, re, %k, arlAssa :a[t Won. 3' x 11-114' net header • steel header not allowed .. — Fasten sheathing to header with 8d common or 12' galvanized box nails of 3' grid pattern as shown max total wall ;; Header to jack -stud strop per wind design. height Min 1000 1 b on both sides of opening opposite : a side of sheathing - 10, — Min. double 2x4 framing covered with min 318" Max ; thick wood structural panel sheathing with height .. 8d common or galvanized box nails of 3" o.c. in all framing (studs, blocking, and sills) typ. — Min length of panel per toble 1 - Min (2) 3500 Ib strop -type hold-downs r.: (embedded into concrete and noiled into framing) }.: _ : r- -,- Min reinforcing of foundation, one #4 bar " 1 r t top and bottom of footing. Lap bars 15' min. 1 t Min foatin size under opening is 12" x 12'. A turned -down slab sholI �e permitted or door openings. Min (1 ) 518' diameter anchor bolt installed per IRC R403-1-6 - with 2' x 2' x 3116' plole washer Header to jock -stud strop per wind design min 1000 Ibf on both sides of opening opposite side of sheathing Fasten top plate to header with two rows of 16d sinker nails at 3' o.c- typ Min. 3/5' wood structural panel sheathing If needed, panel splice edges shall occur over and be noiled to common blocking within middle 24" of portal height. One raw of 3' a. c. nailing is required in each panel edge. Typical portal frame construction Klin double 2x4 post (king and jack studl. Number of jack studs per IRC tables R502.5(1) & (2). Min 1000 Ib hold-down device (embedded into concrete and nailed into framing) 2 Q 2014 APA -The Fnktrce, re, %k, arlAssa :a[t TYPICAL SHEAR WALL NOTES Use 518" dia. by 10" Anchor Bolts (AB's) with single plates and 518" dia. by 12" AB's with double and 3x plates spaced as shown on the drawings. AB's shall have 7" of embedment into footing, shall be centered in the stud wall, and shall project through the bottom plate of the wall and have a 3x3 x 114 plate washer. There shall be a minimum of two bolts per piece of sill located not more than 12 inches or less than 4 inches end of each piece. Anchor bolts to be galvanized per the below requirement (Fasteners in contact with pressure treated lumber). At existing foundation use 518" diameter Simpson Titen HG bolts with minimum of 4" embedment into the existing concrete. All wall sheathing shall be 112" CDX plywood, 518" T1-11 siding, or 7115" OSB with exterior exposure glue and span rated "SR 2410" or better. All free sheathing edges shall be blocked with 2x4 or 2x5 flat blocking except where noted on the drawings or below. All nails shall be 8d or 10d common (8d common nails must be 0.131 inch diameter, Senco KC27 Nails are equivalent. If 10d common nails are called for the diameter must be 0.148 inches, Senco MD23 Nails are equivalent). Nail size and spacing at all sheathing edges shall be as required below or as in the drawings. Nail spacings shall be 12" o.c. for all field nailing except as noted. Hold downs are Simpson "Strang Tie" and shall be installed per the manufacture's recommendation. All floor systems must be blocked solid below member that the hold down is attached to. This block should be equal to or larger than the member the hold down is attached to and be placed as a "squash block". All double and triple studs shall glued and nailed together with l Od's at 3" o.c. for each layer. All 4x studs are to be #2 DF and all 6x studs are to be #1 DF when used for hold downs and shear walls. FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER All fasteners including nuts and washers in contract with pressure treated lumber shall be hot -dipped zinc coated galvanized steel, stainless steel, silicon bronze or copper. Fasteners other than nails, timber rivets, wood screws and lag screws shall be permitted to be of mechanically deposited zinc coated steel in accordance with ASTM B 695, Class 55 minimum. Fasteners exposed to weather must meet the requirements of the pressure treating manufacture's minimum. IN ADDITON, the contractor shall coordinate connector/fastener coating requirements with recommendations from connector/fastener manufacturer and type of pressure treating chemical and retention being used. See Section 2304.10.5 of the 2018 IBC for additional information. ALL WALL STUDS AND ROOF TRUSS TOP CHORDS AND SECONDARY FRAMING LUMBER SHALL BE DOUG -FIR 42 OR BETTER. NOTE: MST STRAPS attaches to (2) 2x or 4x studs in wall above and below unless noted otherwise. Nail all holes with 16d sinkers. Double studs may be use as a substitute for 3x nominal framing call out below. Studs MUST be glued and nailed together with (2) lines of 10d's at 3" on center staggered. Horizontal blocking for shear walls nailed with 8d's shall be minimum of 2x flat and shear walls nailed with l0d's shall be minimum of 3x flat. IN SHEAR WALL SCHEDULE sheathing nailed with 8d's at 6" on center all edges. HOLD DOWN SCHEDULE It is the responsibility of the contractor to locate hold down anchor bolt to accommodate all structural framing_ Anchor bolt to be located nearest the corner or opening at the end of the shear wall. All foundation vents to be a minimum of 12" off centerline of the anchor bolt on either side. Holdown stud to be coordinated with shear wall panel edge framing requirements. Larger stud size controls For holdown anchor bolt embedment greater that foundation depth, thicken footing for 2'-0" either side of holdown anchor bolt to a depth that provides for 3" clear below the bottom of the anchor bolt. Provide (2) additional #4 x 3'-0" pieces of longitudinal rebar at this location. t jJj,, j HD U2 attaches to concrete foundation with a Simpson SSTS 16. HDU2 attaches to double 2x studs or 4x or 6x stud with (6) Simpson SDS 114 X 3 Wood Screws in wall above. Vertical Design STRUCTURAL NOTES General Notes: These structural notes supplement the drawings. Any discrepancyfou nd among the drawings, these notes, and the site conditions shall be reported to the Engineer, who shall correct such discrepancy in writing. Any work done by the Contractor after discovery of such discrepancy shall be done at the Contractor's risk. The Contractor shall verify and coordinate the dimensions among all drawings prior to proceeding with any work or fabrication. The Contractor shall coordinate between the architectural drawings and the structural drawings. The architectural dimensions are taken to be correct when in conflict with the structural drawings. The Contractor is responsible for all bracing and shoring during construction. All construction shall conform to the applicable portions of the latest edition of the International Building Code except where noted Desi n Criteria: 1. Live Load = 40 PSF (Floors) = 25 PSF (Snow) 2. Dead Load - 15 PSF (Roof) = 12 PSF (Floor) = 10 PSF (Walls) = 150 PCF (Concrete) 3. Partition = 10 PSF (Floors) 4. Wind - 2018 IBC Exposure B @ 110 mph 5. Earthquake - 2018 IBC Site Class = D Design Cat. = D Use Group = I R = 6.5 Co - 4 Wo = 3 6. Soil = 1500 PSF, Assumed bearing capacity = 38 PCF, Assumed Active Fluid Pressure - 350 PCF, Assumed Passive fluid Pressure = 0.45. Assumed Coefficient of Friction = 110 PCF, Assumed Soil Density Concrete & Reinforcing Steel: All concrete work shall be per the 2018 IBC Chapter 19. Tolerances shall be per IBC Chapter 19, Section 07. Mixing, placement, and inspection shall be per Sections 03, 04, 05, and 06. All reinforcing shall be ASTIVI A615 Grade 60 except as shown on the plans. Concrete shall be in accordance with ASTM 150. f'c = 2590 PSI @ 28 day slump = 4" maximum, 6% Air entrained. In order to minimize shrinkage cracks recommend that the wlc ratio be under 0.5. Steel: 4. Garage slab and exterior slabs to have minimum thickness of 4" with 6x6 W 1.4x1.4 WW F with vapor barrier. This is at the owner's option to reduce slab cracking. Crack control joints the responsibility of the contractor. Recommend a maximum of 16'x15' grid oras required by geom etry. 5. Install ufer rod as required by local jurisdiction coordinate with project electrician. 1. Anchor bolts shall be ASTM A307. Camenfrtr: 1. 2X structural framing shall be #2 Douglas Fir. 4x structural members shall be #2 Douglas Fir. 6X members shall be #1 Douglas Fir. 2. Provide solid blocking in floor system below all bearing walls and point loads. 3. 2X joists shall be kiln dried and stored in a dry area prior to installation. The moisture content of all wood shall be less than 15%. 4. Floor joists shall be by Boise Cascade or other approved manufacturer. Joist to be installed and braced per manufacturer's requirements. 5. Roof trusses shall be by a pre -approved manufacturer and constructed according to the specifications of the Truss Plate Institute. Truss shop drawings must be stamped by a licensed engineer and be on site at the time of construction. Preliminary truss drawings must be reviewed prior to construction. It is the truss manufacturer's responsibility to inform the engineer of record of any changes from the preliminary truss lay -out. Girder trusses to have a minimum of bearing studs equal to number of plies of truss. All girder trusses shall have Simpson HGT tie down at either end to match number of plies. Truss manufactures are responsible for all bracing of the trusses including end wall bracing and all other bracing between the building and the trusses unless specifically shown otherwise on the drawings. Contractor to coordinate bracing with engineer of record as required. Truss manufacturer to provide all over -framing as required per manufacturer's truss layout.. Coordinate with General contractor and Engineer of Record as required. 6. Glue laminated beams shall be 24F -V8 for cantilevered or continuous beams and 24F -V4 for simple spans. (Fb = 2,400 PSI) (Fv - 190 PSI) (E _ 1,800,000 PSI) (Fcl. = 650 PSI) 7. Continuous and cantilevered glue laminated beams shall not be cambered. All other glue laminated beams shall be cantilevered for U480. Seethe framing plans for any exceptions. 8. All manufactured lumber shall be by Boise Cascade and have the following structural properties: Versa Lam (VL) (Fb = 2,800 PSI) (Fv = 280 PSI) (E - 2,000,040 PSI) (FcL = 750 PSI) 9. Sheathing at roof and floor shall be laid with face grain perpendicular to supports and end joints staggered 4'-0" on center. Provide 118" space at panel edges as required by panel manufacturers. Floor sheathing shall be nailed 6" o.c. edges and 12" field with 10d's and roof sheathing shall be nailed 6" o.c. edges and 12" o.c field with 10d's unless otherwise noted on the drawings. 10. Block and nail all horizontal panel edges at designated shear walls. 11. All beams to be supported by a minimum of a solid post that matches the width of the wall and the width of the beam unless noted otherwise. A 6x beam bearing in 2x6 wall will be a 60. Provide solid squash blocking to match in floor system and match post size in foundation. Contact Engineer of record for any deviations. 12. All fasteners in contact with pressure treated lumber will meet the below requirements. All fasteners including nuts and washers in contract with pressure treated lumber small be hot -dipped zinc coated galvanized steel, stainless steel, silicon bronze or copper. Fasteners other than nails, timber rivets, wood screws and lag screws shall be permitted to be of mechanically deposited zinc coated steel in accordance with ASTM B 695, Class 55 minimum. Fasteners exposed to weather must meet the requirements of the pressure treating manufacture's minimum. IN ADDITON, the contractor shall coordinate cornnectorlfastener coating requirements with recommendations from connector/fastener manufacturer and type of pressure treating chemical and retention being used. See Section 2304.10.5 of the 2018 IBC for additional information. 13. All GWB to be installed per the IBC and Gypsum Association's publication for the Application and Finishing of Gypsum Board, GA -216 Harafware: All connection hardware shall be Simpson "Strong Tie". Connection hardware exposed to the weather or soil shall be treated as in steel above. CAUTION: PLACE TRUSSES PER MANUFACTURER'S RECOMMENDATIONS AND BRACE PER TRUSS COMPANY RECCMMENDATIONS. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING REQUIRED FOR PLACING TRUSSES. NOTE THESE DRAWINGS DO NOT INCLUDE ANY TEMPORARY SHORING OR BRACING. PRECISE ENGINEERING RECCOMENDS ALL SHORING AND BRACING BE DESIGNED AND DETAILED BY A LISENCED ENGINEER. CONTRACTOR TO FIELD VERIFY ALL CONDITIONS AND ALL ELEVATIONS. Ily z w a 0 Precise Engineering Multiple Simple Beam Description Wood Beam Design. A Project Title: Engineer: Project ID: Project Descr: software Printed: 2 DEC 2021, 10:14AM INC. INS -2020, BWd:12.20.5.17 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 SEAM Size: 4x8, Sawn, Fully Unbraced 2.000 ft in Span # 1 Fb : Allowable: 1,337.03 psi 0.000 in Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Max tirlFvRatio = Wood Species: Douglas Fir - Larch Wood Grade: No.2 49.86 psi at 0.040 ft in Span # 1 Fb - Tension 900 psi Fc - Prii 1350 psi Fv 180 psi Ebend- xx 1500 ksi Density 31.21 pcf Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580 ksi Left Support Applied Loads 0.75 Right Support 0+45 0.75 Unif Load: a = 0.0450, S = 0.0250 kilt, Tdb=15.0 R Design Summary _-- D(0.2250) s o.37so Max fblFb Ratio = 0.197. 1 fb : Actual: 264.18 psi at 1.500 It in Span # 1 Fb: Allowable: 1,339.32 psi Load Comb: +D+S+H Max fvlFvRatio = 0.154: 1 * 4x8 fv : Actual: 31.92si at 2.400 ft in Span # 1 p 3.❑ Pt Fv: Allowable: 207.00 psi Load Comb: +D+S+H Max Deflections _ Max Reactions {k} P L Lr S W E H Transient Downward 0.004 in Total Downward 0.006 in Left Support 0.34 0.56 Ratio 9317 Ratio 5823 Right Support 0.34 0.56 LC: S Only LC: +D+S+H Transient Upward 0.000 In Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Wood Beam Design: B Calculations per ND5 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: U3, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Woad Species : Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 9130 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1500 ksi Density 31.21 pcf Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580 ksi Applied Leads Un if Load: D = 0.0150, 5 = 0.0250 klft, THb=15.0 R Design Summary Max fbfFb Ratio 0.351 • 1 fb : Actual : 469.64 psi at 2.000 ft in Span # 1 Fb : Allowable: 1,337.03 psi 0.000 in Load Comb - +D+S+H Max tirlFvRatio = 0.240: 1 fv : Actual : 49.86 psi at 0.040 ft in Span # 1 Fv : Allowable: 207.00 psi Load Comb: +D+S+H Max Reactions {k} D L Lr S W E H Left Support 0.45 0.75 Right Support 0+45 0.75 D(0.2250) 5(0.3750) 4.8 — 40ft --- Transient Downward 0.012 in Ratio 3930 LC: S Only Transient Upward 0.000 in Ratio 9999 LC: Total Downward 0.02D in Ratio 2456 LC:+D+S+H Total Upward 0.000 in Ratio 9999 LC: Precise Engineering Project Title: Engineer: Project ID: Project Descr: Printed: 2 DEC 2021, 10:14AM Simple le Beam File: Big Fir Quit E. P Sof m -m copyright ENERCALC, INC.1983-2020, Build: 12.20.5.17 is Wood Beam Design: C Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size. 4x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species : Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1600 ksi Density 31.21 pcf Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580 ksi Applied Loads Unif Load: D = 0.0150, S = 0.0250 klft, Trib=15.0 ft Design Summary Max fb/Fb Ratio = 0,351-1 fb : Actual : 469.64 psi at 2.000 ft in Span # 1 Fb: Allowable: Fb: Allowable: 1,337.03 psi Load Comb: +D+S+H Load Comb: +D+S+H 0.110: 1 Max fviFvRatio = 0.240: 1 5.400 ft in Span # 1 Fv: Allowable: fv : Actual: 49.66 psi at 0.000 ft in Span # 1 +D+S+H Fv . Allowable: 207.00 psi D L Lr L Load Comb: +D+S+H 0.30 Max Reactions (k) D L Lr S W F H Left Support 0.45 0.75 Right Support 0.45 0.75 Wood Beam Design: D �i0 225Q $�_3750�,_. 4x8 i 4-Q tt Transient Downward 0.012 in Ratio 3934 LC: S Only Transient Upward 0.004 in Ratio 9999 LC: Total Downward 0.020 in Ratio 2456 LC: +D+S+H Total Upward 0.000 in Ratio 9999 LC: Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7.16 SEAM Size: 4x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species : Douglas Fir- Larch Wood Grade: No.2 Fb - Tension 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1600 ksi Density 31.21 pcf Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580 ksi Applied Loads llnif Load: D = 0. 0150, S = 0.0250 klft, Trib= 4.0 ft design Summary Max fb/Fb Ratio = 0.211-1 fb : Actual : 281.79 psi at 3.400 ft in Span # 1 Fb: Allowable: 1,333.02 psi Load Comb: +D+S+H Max fv/FvRatio = 0.110: 1 fv : Actual - 22.70 psi at 5.400 ft in Span # 1 Fv: Allowable: 207.00 psi Load Comb: +D+S+H Max Reactions (k) D L Lr S W E Left Support 0.18 0.30 Right Support 0.18 0.30 ❑ 0.060 S 0.1 O 4x8 6.0 ft r � H Transient Downward 0.016 in T Ratio 4367 LC: S Only Transient Upward 0.000 in Ratio 9999 LC: Total Downward 0.026 in Ratio 2729 LC:+D+S+H Total Upward 0.000 In Ratio 9999 LC: r fy JIL AL O a to Q lu Z lus U [n L LU 0LU �^ ° �0 C K1 8alseCascade Single 11-718" BCI@ 6000-1.8 DF PASS O J01 (Joist) BC CALCI] Member Report Dry 12 spans I No cant. 116 OCS j Repetitive I Glued & nailed December 2, 2021 10:29:34 Build 8104 3081 179 Job name- File name. Address: Description: City, State, Zip: _ Specifier: Customer: Designer: Harold Hahnenkratt Code reports: ESR -1336 Company: Precise Engineering Inc r r Y ■ • r ■ r r ■ r r r TIT ■ ■ r T • 09.09 -DO 18-03.00 61 B2 Total Horizontal Product Length = 28-0040 Reaction Summary (Down 1 Uplift) (lbs) Bearing Live Dead Snow Wind s 4 3 I v B3 Roof Live B1, 4" 3081 179 1810 0/16 B2, 5-112" 123310 33810 5010 63, 2" 518/13 54010 50010 Load Summary Live Dead Snow Wind Roof ocs Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160_% 125% 1 Standard Load Unf. Area (lb1ft2) L 00-00-00 28-00-00 Top 40 12 16 2 pART Unf. Area (lb/ft') L 00-00-00 28-00-00 Top 10 16 3 Wali Conc. Lin. {lb/ft} L 27-00-00 27-00-00 Top 96 16 4 Upper Roof Conc. Lin. (ib/ft) L 27-00-00 27-00-00 Top 218 363 16 5 Low Roof Conc. Lin. (Ib/ft) L 27-00-00 27-00-00 Top 22 38 16 Controls Summary Value %Q Allowable Duration Case Location Pos. Moment 2591 ft -lbs 63.8% 100% 3 20-07-11 Neg. Moment -2532 ft -lbs 62.4% 100% 1 09-09-00 End Reaction 1304 lbs 91.6%fl 115% 7 28-00-00 Int. Reaction 1571 lbs 54.2% 100% 1 09-09-00 End Shear 1293 lbs 67,1% 115% 7 27-10-00 Cont, Shear 893 lbs 53.3% 100% 1 09-11-12 Total Load Deflection LJ550 {0,396"} 43.6% nla 3 19-07-13 Live Load Deflection L1726 (0.3") 66.2% n1a 10 19-04-13 Total Neg. Defl. U999 (-0.048") nla nla 3 05-11-05 Max Defl. 0.396" 39.6% nla 3 19-07-13 Span 1 Depth 18.3 % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material 131 Wall/Plate 4" x 2-5116" 326 lbs 8.7% 22.9% Hem -Fir B1 Uplift 161lbs B2 Wall/Plate 5-112" x 2-5116" 1571 lbs 19.8% 542%o Douglas Fir B3 Hanger 2" x 2-5116" 1304 lbs nla 91.6% Hanger BC FloorValue® Summary BC FloorValue®: Subfioor: 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating; Premium Controlling Location: 20-01-07 Page 1 of 2 Boke cascade Si n g le 11-718" BC 10 6000-1,8 D F N 4WD�o m J01 (Joist) BC CALL® Member Report Dry 12 spans I No cant. 116 OCS I Repetitive f Glued & nailed December 2, 2021 10:29:34 Build 8144 Job name: File name: Address: Description: City, State, Zip: Specifier: Customer: Designer: Harold Hahnenkratt Code reports: ESR -1336 Company: Precise Engineering Inc Cautions Uplift of -161 lbs found at bearing B1. Notes Design meets Code minimum (L1240) Total load deflection criteria.. Design meets User specified (L/480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Hanger Manufacturer: Simpson Strong -Tie, Inc. BC CALC® analysis is based on IBC 2415. Composite El value based on 3!4" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EU LA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered woad products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALCO, BC FRAMERO , AJS-, ALLJOISTO , BC RIM BOARD-, 13GI0 , BOISE GLULAMTm, BC FloorValue&, VERSA -LAMS, VERSA -RIM PLUS@ , Page 2 of 2 Boise Cascade' Single 11-718" 6CID5000-1.7 DF PASSED ��VTT��VTT`%%%%%% F4Ltiff^E^nGDCc-�,_'•5 J01 (Joist) BC CALCO Member Report Dry 12 spans I No cant, 116 OCS I Repetitive I Glued & nailed December 2, 2021 1026:24 Build 8104 Job name: File name: Address: Description: City, State, Zip: Specifier: Customer: Designer: Harold Hahnenhratt Code reports: ESR -1336 Company: Precise Engineering Inc ■ + V I V I r ■ ■ r r r ■ ■ V1. I ■ r r ■ ■ ♦ ■ 09.09.00 18-03-00 B1 B2 B3 Total Horizontal Product Length = 28-00-00 Reaction Summary (Down 1 Uplift) (lbs) Bearing Live Dead SnowWind Roof Live B1, 4" 3081181 31 10 B2, 5-112" 123510 296/0 63,2" 517113 12110 Load Summary Live Dead Snow Wind Roof OCs Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 Standard Load Unf. Area {Iblfix} L 00-00-00 28-00-00 Top 40 12 16 2 pART Unf. Area (lb/ft') L 00-00-00 28-00-00 Top 10 16 Controls Summary Value %Allowable Duration Case Location Pos. Moment 2398 ft -lbs 76.1% 100% 3 20-04-12 Neg. Moment -2428 ft -lbs 77.1% 100% 1 09-09-00 End Reaction 638 lbs 59.7% 100% 3 28-00-00 Int. Reaction 1532 lbs 60.7% 100% 1 09-09-00 End Shear 624 lbs 38.4% 100% 3 27-10-00 Cont. Shear 865 lbs 53.2% 100% 1 09-11-12 Total Load Deflection LI518 [0.421"} 46.4% nla 3 19-04-13 Live Load Deflection U633 (0.344") 75.8% nla 6 19-04-13 Total Neg. Defl. U999 (-0.053") Ma nla 3 05-11-05 Max Defl. 0.421" 42.1% nla 3 19-04-13 Span 1 Depth 18.3 % Allow % Allow Bearing Supports Dim. (LxW) Value support Member Material 131 Wall/Plate 4" x 2" 339 lbs 10.5% 23.8% Hem -Fir B1 Uplift 150lbs B2 Wa€l[Plate 5-112" x 2" 1532 lbs 22.3% 60.7% Douglas Fir B3 Hanger 2" x 2" 638 lbs nla 59.7% Hanger BC FloorValue® Summary BC FloorValue®: Subfloors 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating' Premium Controlling Location: 18-09-14 Cautions Uplift of -150 lbs found at bearing B1. Page 1 of 2 tsh mksecascade Single 11-71$" BCI@ 5000-1.7 DF PJ�SSED e-�rte�nnnpo moatrs J01 (Joist) BC CAI.C® Member Report Dry 12 spans I No cant. 116 CCS I Repetitive I Glued & nailed December 2, 2021 10:26:24 Build 8104 Job name: File name: Address: Description: City, State, Zip: Specifier: Customer: Designer: Harold Hahnenkratt Code reports: ESR -1336 Company: Precise Engineering Inc Notes Design meets Code minimum (Ll240) Total load deflection criteria. Design meets User specified (LI480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. Hanger Manufacturer: Simpson Strong -Tie, Inc. BC CALCE) analysis is based on IBC 2015. Composite EI value based on 314" thick 0S13 sheathing glued and nailed to member. Design based on Dry Service Condition, Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (FULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call [Bfl0)232-0788 before installation. BC CALC@, BC FRAMER] , AJS-, ALLJOISTO , BC RIM BOARDIm, BCI®, BOISE GLULAMw, BC FloorValue@ , VERSA-I.AMIO), VERSA -RIM PLUS®, Page 2 of 2 Base Cascade I Single 11-718" BCI® 6000-1.8 DF PASSE❑ [.Y.. !._£uf: .���•� as-. _..'� J01 (Joist) BC CALL® Member Report Dry 12 spans I No cant. j 16 DCS I Repetitive I Glued & nailed December 2, 2021 10:34:10 Build 8104 5 Job name: File name: Address: 4 Description: City, State, Zip: Specifier: Customer: Designer: Harold Hahnenkratt Code reports: ESR -1336 r r r r r Company: Precise Engineering Inc BC F1oorValue® Summary _ BC FloorValueg: Subfloor: 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating. Premium Controlling Location: 20-01-00 Page 1 of 2 5 4 3 r . . r r 2 r I r r r r r r r r I. r r r . r r r1 . . 11, r . r r r r r . r r . r r 12.05.04 15-0&12 B1 B2 B3 Total Horizontal Product Length = 26-00-00 Reaction Summary (Down 1 Uplift) (lbs) Bearing Live _ Dead Snow Wind Roof Live B1, 4" 381 /84 64/0 018 B2, 5-112" 114310 30810 41 10 133, 4" 461 134 52310 50310 Load Summary Live Dead snow wind Roof ocs Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 Standard Load Unf. Area (Iblft2) L 00-00-00 28-00-00 Top 40 12 16 2 pART Unf. Area (lblft2) L 00-00-00 28-00-00 Top 10 16 3 Wall Conc. Lin. (lb1ft) L 27-00-00 27-00-00 Top 96 16 4 tipper Roof Conc. Lin. (lb/ft) L 27-00-00 27-00-00 Top 218 363 16 5 Low Roof Conc. Lin. (Ib1ft) L 27-00-00 27-00-00 Top 22 38 16 Controls Summary value % Allowable Duration Location Pos. Moment 1922 ft -lbs 47.3% 100% _Case 3 21-07-01 Neg. Moment -2002 ft -lbs 49.3% 100% 1 12-05-04 End Reaction 1246 lbs 76.0% 115% 7 28-00-00 Int. Reaction 1452 lbs 50.1% 100% 1 12-05-04 End Shear 1224 lbs 63.5% 115% 7 27-08-00 Cont. Shear 765 lbs 45.7% 100% 1 12-08-00 Total Load Deflection 0824 (0.223") 29.1% nla 3 20-06-14 Live Load Deflection L/1073 (0,171") 44.7% Ma 10 20-06-14 Total Neg. Defl. L1999 (-0.038") nla nla 3 07-10-12 Max Defl. 0.223" 22.3% nla 3 20-06-14 Span I Depth 15.5 % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 4" x 2-5116" 445 lbs 11.9% 31.2% Hem -Fir B2 Wall/Plate 5-112" x 2-5116" 1452 lbs 18.3% 501% Douglas Fir B3 Wall/Plate 4" x 2-5116" 1246 lbs 33.3% 76.0%fl Hem -Fir BC F1oorValue® Summary _ BC FloorValueg: Subfloor: 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating. Premium Controlling Location: 20-01-00 Page 1 of 2 13dseCascacW Single 11-718" BCl® 6000-1.8 DF cx NnDwoosvno TS J01 (Joist) BC CALL® Member Report Dry 12 spans I No cant. 116 OCS I Repetitive I Glued & nailed December 2, 2021 10;34:10 Build 8104 Job name: File name: Address: Description: City, State, Zip: Specifier: Customer: Designer: Harold Hahnenkratt Code reports: ESR -1336 Company: Precise Engineering Inc Notes Design meets Code minimum (L1240) Total load deflection criteria. Design meets User specified (L1480) Live load deflection criteria. Design meets arbitrary (11") Maximum Total load deflection criteria. BC CALL® analysis is based on IBC 2015. Composite El value based on 314" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. Calculations assume member is fully braced. Disclosure Use of the Boise Cascade Software Is subject to the terms of the End User License Agreement (EUtA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building cede -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALCA7, BC FRAMERO , AJS-, ALLJOIST@ , BC RIM BOARDTIA, BCI®, BOISE GLULAM-, BC FloarValue@ , VERSA-LAMO, VERSA -RIM PLUS0 , Page 2 of 2 Boise cascade' Single 11-718" BCI@ 6000-1.8 DF PAsS�D J01 (Joist) BC CALCO Member Report Dry 12 spans I No cant, 116 OCS I Repetitive I Glued & nailed December 2, 2021 10:35:03 Build 8104 Job name: • File name: Address: Description: City, State, Zip: Specifier: Customer: Designer: Harold Hahnenkratt Code reports: ESR -1336 Company: Precise Engineering Inc ■ ■ • r r r • r r r r • r .I ■ 2 r r BC FloorValue® Summary BC FloorValueO: Subfloor: 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating: Premium Controlling Location: 20-01-00 Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. BC CALCO analysis is based on IBC 2015. Composite EI value based on 314" thick OSB sheathing glued and nailed to member, Design based on Dry Service Condition. Calculations assume member is fully braced. Page 1 of 1 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALCI, BC FRAMER®, AJST", ALLJOIST@), BC RIM BOARDTM, ,10, BOISE GLULAMT , BC FloorValue4 , VERSA -LAMS, VERSA -RIM PLUS9) 12.05.04 r r r r r r r r B1 B2 Supports B3 Value Total Horizontal Product Length = 28-00-00 i BC FloorValue® Summary BC FloorValueO: Subfloor: 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating: Premium Controlling Location: 20-01-00 Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. BC CALCO analysis is based on IBC 2015. Composite EI value based on 314" thick OSB sheathing glued and nailed to member, Design based on Dry Service Condition. Calculations assume member is fully braced. Page 1 of 1 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALCI, BC FRAMER®, AJST", ALLJOIST@), BC RIM BOARDTM, ,10, BOISE GLULAMT , BC FloorValue4 , VERSA -LAMS, VERSA -RIM PLUS9) 12.05.04 15-M12 B1 B2 Supports B3 Value Total Horizontal Product Length = 28-00-00 B1 Reaction Summary (Down 1 Uplift) (lbs) 452 lbs 12,1% 31.7% Bearing Live Dead Snow --Wind Roof Live B1, 4" 381 184 71 10 48.9% Douglas Fir B3 132, 5-112" 114310 27414 563 lbs 15.0% 39.5% B3, 4" 461/34 10210 Load Summary Live Dead Snow Wind Roof ocs Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 Standard Load Unf. Area (lblft2) L 00-00-00 28-00-00 Top 40 12 16 2 pART Unf. Area (lb/ft') L 00-00-00 28-00-00 Top 10 16 Controls Summary value % Allowable Duration Case Location Pos. Moment 1768 ft -lbs 43.5% 100% 3 21-02-03 Neg. Moment -1916 ft -lbs 47,2% 1 DO% 1 12-05-04 End Reaction 563 lbs 39.5% 100% 3 28-00-00 Int. Reaction 1418 lbs 48.9% 100% 1 12-05-04 End Shear 535 lbs 32.0% 100% 3 27-08-00 Cont. Smear 738 lbs 44.1% 100% 1 12-08-00 Total Load Deflection U898 (0.204°) 26.7% nla 3 20-06-14 Live Load Deflection U1073 (0.171") 44.7% rola 6 20-06-14 Total Neg. Defl. U999 (-0.035") nla nla 3 07-11-10 Max Deft. 0,204" 20.4% nla 3 24-06-14 Span I Depth 15.5 BC FloorValue® Summary BC FloorValueO: Subfloor: 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating: Premium Controlling Location: 20-01-00 Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. BC CALCO analysis is based on IBC 2015. Composite EI value based on 314" thick OSB sheathing glued and nailed to member, Design based on Dry Service Condition. Calculations assume member is fully braced. Page 1 of 1 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALCI, BC FRAMER®, AJST", ALLJOIST@), BC RIM BOARDTM, ,10, BOISE GLULAMT , BC FloorValue4 , VERSA -LAMS, VERSA -RIM PLUS9) % Allow % Allow Bearing Supports Dim. (LxW)_ Value Support Member Material B1 Wall/Plate 4" x 2-5116" 452 lbs 12,1% 31.7% Hem -Fir B2 Wall/Plate 5-112" x 2-5116" 1418 lbs 173% 48.9% Douglas Fir B3 Wall/Plate 4" x 2-5116" 563 lbs 15.0% 39.5% Hem -Fir BC FloorValue® Summary BC FloorValueO: Subfloor: 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating: Premium Controlling Location: 20-01-00 Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. BC CALCO analysis is based on IBC 2015. Composite EI value based on 314" thick OSB sheathing glued and nailed to member, Design based on Dry Service Condition. Calculations assume member is fully braced. Page 1 of 1 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALCI, BC FRAMER®, AJST", ALLJOIST@), BC RIM BOARDTM, ,10, BOISE GLULAMT , BC FloorValue4 , VERSA -LAMS, VERSA -RIM PLUS9) Boise Cascade' I Single 11-718" BCI® 6000-1.8 DF pASSEo J03 (Joist) BC CALL® Member Report Dry 1 1 span I No cant. 116 OCS j Repetitive I Glued & nailed December 2, 2021 10:55:59 Build 8104 Job name: File name: Address: f` _/I Description: City, State, Zip: Specifier: Customer: Designer: Harold Hahnenkratt Code reports: ESR -1336 Company: Precise Engineering Inc k B1 05-00-90 Total Horizontal Product Length = 05-00-00 B2 Reaction Summary (Down 1 Uplift) (Ibs) a 3 r • r . r21 r r • • • r r • r • r r • • r r1 • • • r r r • • r r r r • • • r 05-00-90 Total Horizontal Product Length = 05-00-00 B2 Reaction Summary (Down 1 Uplift) (Ibs) Bearing Live dead Snow Wind Roof Live B1, 2" 161/0 10510 7614 82, 4" 17210 39410 40810 Load Summary Live Dead Snow Wind Roof oc5 Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 1 Standard Load Unf. Area (Iblft') L 00-00-00 05-00-00 Top 40 12 16 2 Part Unf, Area (lb/ft') L 00-00-00 05-00-00 Top 10 16 3 wall Conc. Lin. (lb/ft) L 04-00-00 04-00-00 Top 96 16 4 Conc. Lin. (lb/ft) L 04-00-00 04-00-00 Top 218 363 16 Controls Summary Value % Allowable Duration Case Location Pos. Moment 577 ft -lbs 12.4% 115% 2 04-00-00 End Reaction 829 lbs 50.6% 115% 3 05-00-00 End Shear 807 lbs 41.9% 115% 3 04-08-00 Total Load Deflection LJ999 (0.013") Ma nla 3 03-01-08 Live Load Deflection 1J999 (0,007") Ma nla 6 02-11-10 Max Defl. 0.013" Ma nla 3 03-01-08 Span 1 Depth 4.7 % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Hanger 2" x 2-5116" 266 lbs nla 21.5% Hanger B2 Wall/Plate 4" x 2-5116" 829 lbs 22.1% 50.6% Hem -Fir BC FloorValue® Summary BC FloorValue®: Subfloor: 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Raking: Premium Controlling Location: 03-06-14 Notes Design meets Code minimum (LI240) Total load deflection criteria. Design meets User specified (L1480) Live load deflection criteria. Design meets arbitrary (1" ) Maximum Total load deflection criteria. Hanger Manufacturer: Simpson Strong -Tie, Inc. BC CALC@) analysis is based on IBC 2015, Composite EI value based on 314" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. Calculations assume member is fully braced. Page 1 of 1 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALCV, BC FRAMER(&, AJSTM, ALLJOIST@ , BC RIM BOARDTM, BCI@) , BOISE GLULAMT , BC FloorValue@) , VERSA -LAM@), VERSA -RIM PLUS®, Precise Engineering Multiple Simple Beam Description : Upper Floor Wood Beam Design: A 1:31=AM Size : 5.25xl 1 .875, VersalLam, Fi Using Allowable Stress Design i Wood Species : Boise Cascade Fb-Tension 2800 psi Fc -Prll Fb - Cam pr 2800 psi Fc - Perp Applied Loads Unit load: D=0.0150, S = 0.0250 kilt, Tdb= 3.0 ft Unit Load: D = 0.0960 kl% Trib= 1.0 ft Ur it Load: D = 0.0220, L = 0.040 kilt, Trib= 0.670 ft Unit Load: D = 0.0 160, S = 0.0250 kift, Trib=1.0 ft Design Summar Max fbiFb Ratio = 0.344; 1 Project Title: Engineer: Project ID: Project Descr: software Printed: 2 DEC 2021, 3:33PM INC. 1983-2020. Bulld:12.20.5.17 Calculations per NDS 2018, IBC 2018, GEC 2019, ASCE 7-16 ASCE 7-10 Load Combinations, Major Axis Bending Wood Grade : Versa Lam 2.0 2800 West 3000 psi Fv 285 psi Ebend- xx 2004 ksi Density 41.76 pct 750 psi Ft 1950 psi Eminbend - x)'530120482 ksi fb : Actual : 1,066.38 psi at 9.000 ft in Span # 1 Fb: Allowable: 3,104.23 psi S = 0.0250 loft, 17.0 to 18,0 ft, Trib= 6.50 H Load Comb: +D+S+H Ratio Max fv/FvRatio T 0.160: 1 lb: Actual : fv : Actual : 52.37 psi at 0.000 ft in Span # 1 Fv: Allowable: 327.75 psi Max fviFvRatio = Load Comb: +D+S+H 224.44 psi at 17,040 ft in Span # 1 Max Reactions (k) o L Lr S W E Left Support 1.54 0.24 0.90 Right Support 1.54 0.24 0.90 Wood Beam Design _:i3 BEAM Size Wood Species: Fb - Tension Fb - Compr 5.25x11.875 -- 18.0 ft Max Deflections H Transient Downward 0.245 in Total Downward 0.439 in Ratio 1051 Ratio 492 LC: +L+S LC: +D+S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 1.75x11.875, VersaLam, Fully Braced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Boise Cascade Woad Grade: Versa Lam 20 2800 West 2,800.0 psi Fc - Prll 3,000.0 psi Fv 285.0 psi Ebend- xx 2,000.0 ksi Density 41.760 pcf 2,800.0 psi Fc - Perp 750.0 psi Ft 1,950.0 psi Eminbend - xx 1,036.83 ksi Applied Loads Unif Load: D = 0.0220, L = 0.040 klft, Trib=1.330 ft Unit Load: D = 0.0960 klft,17.0 to 11$.0 ft, Trib= 1.0 ft Unit toad: D = 0.0150, S = 0.0250 loft, 17.0 to 18,0 ft, Trib= 6.50 H Point: D =1.140, S =1.90 k (0717,0 ft Design Summar• Ratio Max fb/Fb Ratio = 0.415. 1 lb: Actual : 1,162.16 psi at 9.840 ft in Span # 1 Fb : Allowable: 2,80000 psi Load Comb: +D+L+H Max fviFvRatio = 0.685: 1 fv : Actual : 224.44 psi at 17,040 ft in Span # 1 Fv : Allowable: 327.75 psi Load Comb: +D+S+H Max Reactions (k) D i Lr S W E Left Support 0.33 0.48 0.11 Right Support 1.53 0.48 1.95 __PJ4.02926 L 0.05320 D(0.07 1825) 1.75x11.875 18.0 ft r - Max Deflections H Transient Downward 0.401 in Total Downward 0.532 in Ratio 538 Ratio 405 LC: +L+S C: +D+0.750L+0.7505+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Precise Engineering Project Title: Engineer: Project ID: Project Descr: Printed: 2 DEC 2021, 3:33PM Multiple1 Simple Beam .e: Big Fir urt E.ec6 Software coavri®ht ENERCALC, INC. 1983-2020. Bu11d:12.20.5.17 Wood Beam Design: C BEAM Size . 5.5x'19.5, GLB, Full Using Allowable Stress Calculations per NDS 2018, IBC 2018, CIBC 2019, ASCE 7.16 with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: DF/DF Wood Grade: 24F - V4 Fb - Tension 2,400.0 psi Fc - Prll 1,650.0 psi Fv 265.0 psi Ebend- xx 1,800.0 ksi Fb - Compr 1,850.0 psi Fc - Perp 650.0 psi Ft 1,100.0 psi Eminbend - xx 950.0 ksi Applied toads Unif Load: D = 0. 0150, S = 9.0250 klft, 0.0 ft to 2.50 ft, Tdb= 10.0 ft Unif Load: D = 0.4060, L = 0.390, S = 0.3750 klft, 2.50 to 8.750 ft, Tdb= 1.0 ft Unif Load: D = 0.0220, L = 0.040 klft, 8.670 to 19.0 ft, Tdb= 9.0 ft Unif Load: D = 0.1410, S = 0.0750 kfft, 8.670 to 19.0 ft, Tdb= 1.0 It Point: D = 4.540, L = 0.240, 5 = 0.90 k @ 2.50 ft Point: D =1.530, L = 0.480, 5 =1.950 k @ 8.670 ft Unif Load: D = 0.0 150, S = 0.0250 kfft, 2.50 to 19.0 ft Design Summary Max fb/Fb Ratio = 0.731 1 fb : Actual: 1,928.21 psi at 8.677 ft in Span # 1 Fb. Allowable: 2,636.96 psi Load Comb - +D+0.750L+0.750S+H Max fvlFvRatio = 0.486:1 fv. : Actual: 147.98 psi at 0.000 ft in Span # 1 Fv: Allowable: 304.75 psi Load Comb: +D+0.7501 -+0.7505+H Density 31.290pcf ro 50) Dt0.15p 5.5x19.5 ;* 19.0 ft Max Reactions (k) D L Lr S W E H Transient Downward 0.398 in Total Downward 0.564 in Left Support 5.37 3.20 4.47 Ratio 573 Ratio 403 Right Support 4.37 3.68 2.54 LC: +L+S .C: +D+0.7561 -+0.1505+H Transient Upward 0.000 in Total Upward 4,000 in Ratio 9999 Ratio 9999 LC: LC: Wood Beam Design: D _ Calculations per Nos 2018, IBC 2018, CBC 2019, ASCE 7.16 BEAM Size: 3.5x92, GLB, Fully Unbraced Using A]lowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: DF/DF Woad Grade: 24F - V4 Fb - Tension 2400 psi Fc - Prll 1650 psi Fv 265 psi Ebend- xx Fb - Compr 1850 psi Fc - Perp 650 psi Ft 1100 psi Eminbend - xx Applied Loads Unif Load: D = 0.0150, S = 0.0250 kift, Trib= 2.670 ft Design Summary Max fblFb Ratio = 0.209-1 fb : Actual: 503.60 psi at 8.125 ft In Span # 1 Fb: Allowable: 2,410.92 psi Load Comb: +D+S+H Max fvlFvRatio = 0.089: 1 fv : Actual: 27.27 psi at 15.275 ft in Span # 1 Fv: Allowable: 304.75 psi Load Comb: +D+S+H Max Reactions (k) 0 L Lr 5 W E Left Support 0.33 0.54 Right Support 0.33 0.54 1800 ksi Density 31.21 pcf 950 ksi D(0.D4005) S[0.06675 3.5x12 16.250 ft Max Deflections H Transient Downward 0.196 in Total Downward 0.186 in Ratio 1680 Ratio 1050 LC: 5 Only LC: +D+S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Precise Engineering Multiple Simple Beam Wood Beam Design: E Project Title: Engineer: Project ID: Project Descr: Software Printed; 2 DEC 2021, 3:33PM INC. 1983-2020, Build:12,20.5.17 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7.16 BEAM Size: 1.75x11.875, VersaL.am, Fully Braced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species : Boise Cascade Wood Grade: Versa lam 2.0 2800 West Fb - Tension 7,800.4 psi Fc - Prll 3,000.0 psi Fv 285.0 psi Ebend- xx 2,000.0 ksi Fb - Compr 2,800.0 psi Fc - Perp 750.0 psi Ft 1,950.0 psi Eminbend - xx 1,036.83 ksi Applied Loads Max Deflections Unif Load: D = 0.0780, L = 0. 1210, S = 0.0580 klft, Trib=1.0 ft Desl�r n Summary H Transient Downward 0.001 in Total Downward 0.001 in Max fb/Fb Ratio = 0.023. 1 9999 fb : Actual : 65.26 psi at 1.500 ft in Span # 1 Fb . Allowable : 2,800.00 psi Load Comb: +D+L+H Max fv/FvRatio = 0.026: 1 LC: fv : Actual: 7.47 psi at 2020 ft In Span # 1 Fv : Allowable: 285.00 psi ASCE 7-16 Density 41.760 pof i 1.75x11.875 + h 3-0 ft -- ...- -- Load Comb: +D+L+H Max Deflections Max Reactions (k) n L Lr 5 W E H Transient Downward 0.001 in Total Downward 0.001 in Left Support 0.12 0.18 0.09 Ratio 9999 Ratio 9999 Right Support 0.12 0.18 0.09 LC: +L+S .C: +D+0.750L+0.7505+H Transient Upward 0.000 in Total Upward 0.000 In Ratio 9999 Ratio 9999 LC: LC: Wood Beam Design: F Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size: 1.75x11.875, Versaf-am, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: Boise Cascade Wood Grade: Versa Lam 2.0 2800 West Fb - Tension 2,800.0 psi Fc - Pril 3,000.0 psi Fv 2B5.0 psi Ebend- xx 2,000.0 ksi Density 41.760 pof Fb - Compr 2,800.0 psi Fc - Perp 750.0 psi Ft 1,950.0 psi Eminbend - xx 1,036.83 ksi Applied Loads Unif Load: D = 0.0220, L = 0,040 kfft, Trib=1.330 ft Point: D = 0.120, L = 0.180, S = 0.090 k @ 1.0 ft Design Summary �- µi ... Max fb/Fla Ratio = 0.080-1 -.156.32 ❑.62925J,t(d_05320} fb :Actual psf at 2,000 ft in Span # 1 T Fb: Allowable: 1,942.46 psi Load Comb: +D+L+H Maxfv/FVRaGo= 0.105:1 1-75x11-875 fv : Actual: 30.06 psi at 0.000 ft in Span # 1 rt1 ff Fv: Allowable: 285.00 psi Load Comb: +D+L+H Max Deflections Max Reactions (k) D L Lr S W E H Transient Downward 0,005 in Total Downward 0.007 in Left Support 0.19 0.31 0.08 Ratio 9999 Ratio 9902 Right Support 0.11 0.19 0.02 LC: +L+S LC: +D+L+H Transient Upward 0.000 in Total Upward O.ODO In Ratio 9999 Ratio 9999 LC: LC: Precise Engineering Multiple Simple Beam Wood Beam Design: F1 Project Title: Engineer: Project ID: Project Descr: Printed: 2 DEC 2021, 3:33PM Software copyright ENERCALC, INC. 1983-2020. Build: 12.20.5.17 Calculations per Nos 2418, IBC 2018, CBC 2019, ASCE 7-15 BEAM Size: 1.75x11.875, VersaLam, Fully Braced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: Boise Cascade Wood Grade: Versa Lam 2.0 2800 West Fb - Tension 2,800.0 psi Fc - PHI 3,G00.0 psi Fv 285.0 psi Ebend- xx 2,000.0 ksi Density 41.760 pcf Fb - Compr 2,800.0 psi Fc - Perp 750.0 psi Ft 1,950.9 psi Eminbend - xx 1,036.83 ksi Aojfed Loads Unif Load: D = 0.0220, L = 0.040 klft, Trib= 5.0 ft ❑esign Summary Max fblFb Ratio = 0.038. 1 fb : Actual: 101.67 psi at 1.500 ft in Span # 1 Fb: Allowable: 2,800.00 psi Load Comb: +D+L+H Max fv/FvRatio = 0.041 : 1 fv : Actual: 11.63 psi at 2.020 ft in Span # 1 Fv . Allowable: 285,00 psi Load Comb: +D+L+H Max Reactions (k) o L Lr s w E Left Support 0.17 0.30 Right Support 0.17 0.30 _ o[o.t�oZs_{o-201-------- -- f 1.75x71.875 3-0 i Max Deflections H Transient Downward 0.001 in Total Downward 0.001 in Ratio 9999 Ratio 9999 LC: L only LC: +D+L+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: Wood Beam Design: F2 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE-7-116 BEAM Size: 1.75x11.875, Versal-am, Fully Embraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: Boise Cascade Wood Grade: Versa Lam 2.0 2800 West Fb - Tension 2,800.0 psi Fc - PHI 3,000.0 psi Fv 285.0 psi Ebend- xx 2,000.0 ksi Density 41.760 pcf Fb - Com pr 2,800.0 psi Fc - Perp 750.0 psi Ft 1,950.0 psi Eminbend - xx 1,036.83 ksi Applied Loads Unif Load: D = 0,0220, L = 0,040 kilt, Tdb=1.330 ft Point: D=0,170, L = 0.30 k @ 9.50 ft ❑esign Summary Max fb1Fb Ratio = 0.542-1 fb : Actual: 620.90psf at 7.200 ft in Span # 1 Fb: Allowable: 1,146.58 psi Load Comb: +D+L+H Max fv/FvRatio 0.199: 1 fv : Actual : 56.83 psi at 11.040 ft in Span # 1 Fv: Allowable: 285.00 psi Load Comb: +D+L+H Max Reactions (k) o L Lr s w E Left Support 0.21 0.38 Right Support 0.31 0.56 _ ❑ 0.02928 L 005_3_20 I 1.75x11.875 r_ 12-0 ft r -- Max Deflections H Transient Downward 0.074 in Ratio 1953 LC: L Only Transient Upward 0.000 in Ratio 9999 LC: Total Downward 0.115 in Ratio 1255 LC:+D+L+H Total Upward 0.000 in Ratio 9999 LC: Precise Engineering Multiple Simple Beam Wood Beam Design. G Project Title: Engineer: Project ID: Project Deser: Printed: 2 DEC 2021, 3:33PM INC. 1983-2020. Bulld:12.20.5.17 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7.16 BEAM Size: 1.75x11.875, VersaLam, Fully Braced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Woad Species : Boise Cascade Wood Grade : Versa Lam 2.0 2800 West Fb - Tension 2800 psi Fe - Pril 3000 psi Fv 285 psi Ebend- xx 2000 ksi Density 41.76 pcf Fb - Campr 2800 psi Fc - Perp 750 psi Ft 9950 psi Eminbend -)x530120482 ksi Applied Loads Unif Load: D = 0.0220, L = 0.040 k9t, Tdb=1.330 ft Point: D =1.40, S= 2.40 k A 1.0 ft Design Summa Max fb/Fb Ratio = 0.351; 1 fb : Actual: 1,129.37 psi at 4.400 ft in Span # 1 Fb: Allowable: 3,220.00 psi 556 Load Comb: +D+0.750L+0.750S+H Max fv/FvRatio = 0.823: 1 Total Upward fv : Actual : 269.72 psi at 0.000 ft in Span # 1 Fv: Allowable : 327.75 psi 180.00 psi Load Comb: +D+S+H +D+L+H Max Reactions [k] D L Lr 5 W E Left Support 1.53 0.40 2.24 Right Support 0.31 0.40 0.16 Wood Beam Design: H BEAM Size Wood Species: Fb - Tension Fb - Campr D 17.02928 L 0.0532D 1.75x11.875 15.0 ft H Transient Downward 0.245 in Total Downward 0.323 in Ratio 733 Ratio 556 LC: +L+S .C: +D+0.750L+0.750S+H Transient Upward 0.000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: 180.00 psi LC: Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16 4x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Douglas Fir - Larch Wood Grade: No.2 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx Applied Loads Unif Load: D = 0.0150, S = 0.0250 klft., Tdb= 3.0 It Unif Load: D = 0.0960 kA Tdb= 1.0 ft Unif Load: D = 0.0220, L = 0.040 klft, Trig 7.50 ft Design Summar Max fb/Fb Ratio = 0.919; 1 fb : Actual: 1,067.27 psi at 3.000 ft in Span # 1 Fb . Allowable : 1,160.76 psi Load Comb: +D+L+H Max fv/FvRatio = 0.478: 1 fv : Actual: 85.97 psi at 5.400 ft in Span # 1 Fv : Allowable: 180.00 psi Load Comb: +D+L+H Max Reactions (k) 0 L Lr S W E Left Support 0.92 0.90 0.23 Right Support 0.92 0.90 0.23 1600 ksi Density 39.21 pcf 580 ksi ------------ 4x8 1, 6.0 ft r - Max Defaections H Transient Downward 0.062 in Ratio 1164 LC: +L+S Transient Upward 0.000 in Ratio 9999 LC: Total Downward 0.100 in Ratio 720 LC:+D+L+H Total Upward 0.000 in Ratio 9999 LC: Precise Engineering Multiple Simple Beam Wood Beam Design: Project Title: Engineer: Project ID: Project Descr: Printed: 2 DEC 2021, 3:33PM File: Big Fir ourSE.ei Software copyright ENERCALC, INC. 1983-2020, BUN: 12.205.17 Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size : 4x8, Sawn, Fully Unbraced Max fv/FvRatio = 0.385; 1 Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 900 psi Fc - FIN 1350 psi Fv 180 psi Ebend- xx 1600 ksi Density 31.21 pef Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580 ksi Applied Loads 0.59 1.08 Unif Load: D = 0.0220, L = 0,040 kfft, Trib=13.50 It C3eSlgfi Summary 0(0-2970) L 0-540j -- — _ Max fblFb Ratio 0.563. 1 fb : Actual: 655.15 psi at 2.000 ft in Span # 1 Nil Fb : Allowable: 1,163.69 psi Load Comb: +D+L+H Max fv/FvRatio = 0.385; 1 fv : Actual: 69.27 psi at 4.000 ft in Span # 1 Fv : Allowable: 180.00 psi Load Comb: +D+L+H Max Reactions (k) D L Lr 5 W E Left Support 0.59 1.08 Right Support 0.59 1.08 eA 4xa 4.0 rt Max Deflections H Transient Downward 0.018 in Total Downward 0.027 in Ratio 2729 Ratio 1761 LC: L Only Transient Upward 0.000 in Ratio 9999 LC: LC:+D+L+H Total Upward 0+000 in Ratio 9999 LC: Precise Engineering Multiple Simple Beams _Description : Upper Floor CONT Wood Beam Design: J Project Title: Engineer: Project ID: Project Descr: Software Calculations Printed: 2 DEC 2421, 3:38PM INC. 1983-2020, Build:12.20.5.17 NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 BEAM Size : 4x8, Sawn, Rally Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 900 psi Fc - PHI 1350 psi Fv 180 psi Ebend- xx Fb - Com pr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx Applied Loads Unif Load: D = 0,0150, S = 0.0256 kfft, Trib=14.50 It Unit Load: D = 0,0960 klft, Trib=1,0 It Unif Load: D = 0.0220, L = 0,040 kilt, Trib= 6.0 It De,2 n Summary Max fb/Fb Ratio = 0.822; 1 fb : Actual : 1,097.52 psi at 2,500 ft in Span # 1 Fb : Allowable : 1,335.02 psi D.048 in Load Comb: +D+0.750L+0.7505+H Max fv/FvRa#io = 0.487: 1 Ratio fv : Actual : 100.79 psi at 4.400 ft in Span # 1 Fv : Allowable: 207.00 psi 0.000 in Load Comb: +D+0.750L+0.750S+H Max Reactions (k) D L U S W E Left Support 1.11 0.60 0.91 Right Support 1.11 0.60 0.91 Wood Beam Design: K -- I ,I 4x8 5.0 ft 1600 ksi Density 31.21 pcf 580 ksi Max Deflections 208.53 psi at 2.000 ft in Span # 1 5533 H Transient Downward D.048 in Total Downward 0.071 in Ratio 1252 Ratio 841 LC: +L+S C: +D+0.750L+0.750S+H Transient Upward 0.000 in Total Upward 0.000 In Ratio 9999 Ratio 9999 Load Comb: LC: Max Reactions {k} LC: _ Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7.16 BEAM Size : 4x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species : Douglas Fir - Larch Wood Grade: No.2 Fb - Tension 900 psi Fc - PHI 1350 psi Fv 180 psi Ebend- xx 1600 ksf Density 31.21 pcf Fb - Compr 900 psi Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580 ksi Applied Loads Unif Load: D = 0. 0150, S = 0.6250 k1Vi, Tri b-- 3.0 ft Unif Load: D = 0.0960 klft, Trib=1.0 ft Unif Load: D = 0.0220, L = 0,040 klft, Trib=1.330 ft Design Summary Max fb1Fb Ratio = 0.156.1 fb : Actual : 208.53 psi at 2.000 ft in Span # 1 5533 Fb : Allowable : 1,337.03 psi Total Upward 0.000 in Load Comb: +D+0.750L+0.7505+H Max fvfFvRatio = 0.107: 1 fv : Actual : 22,05 psi at 0.000 ft in Span # 1 Fv : Allowable : 207.00 psi Load Comb: +D+0.750L+0.750S+H Max Reactions {k} P L Lr S W E F� Left Support 0.34 0.11 0.15 Right Support 0.34 0.11 0.15 ON0 4i"04 .-- -.--__. Transient Downward 0.004 in Ratio 9999 LC: +L+S Transient Upward 0.000 in Ratio 9999 LC: Total Downward 0.009 in Ratio 5533 .C: +D+0.750L+0.750S+H Total Upward 0.000 in Ratio 9999 LC: Precise Engineering _... _. ..... ... ... ------.. Multiple Simple Beam Wood Beam Design: L Project Title: Engineer: Project ID: Project Descr. Software Printed: 2 DEC 2421, 3:38PM INC. 1983-2020, Bulld:12.20.5,17 Calculations per NDS 2018,160 2018, CIBC 2019, ASCE 7-16 BEAM Size: 4x8, Sawn, Fully Unbraced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: Douglas Fir - Larch Wood Grade: No.2 Fib - Tension 900 psi Fc - Prll 1350 psi Fv 180 psi Ebend- xx 1600 ksi Density 31.21 pcf Fb - Compr 906 psf Fc - Perp 625 psi Ft 575 psi Eminbend - xx 580 ksi Applied Loads Unif Load: D = 0.0220, L = 0,040 klft, Tdb=14.0 ft Design Summary D(o_ 3oso� L(o _5sat Max Ratio = 0.328; 1 fb : Actual : 382.17 psi at 1.500 It in Span # 1 Fb : Allowable: 1,165.38 psi "4x8W4 Load Comb: +D+L+H Max fv/FvRatio = 0.257: 1 jNow fv : Actual : 46.18 psi at 2.400 ft in Span # 1 3.0 ft { Fv : Allowable: 180.00 psi Load Comb: +D+L+H Max Defiections Max Reactions (k) 9 L Lr 5 W E H Transient Downward 0.006 in Total Downward 0.009 in Left Support 0.46 0.84 Ratio 6239 Ratio 4025 Right Support 0.46 0.84 LC: L Only LC: +D+L+H Transient Upward 0,000 in Total Upward 0.000 in Ratio 9999 Ratio 9999 LC: LC: IM SAWN 339 V3SV IN -:V M 53Hr-N! — a OS u aawzQ! d 113n woli W139 r r j Ed IL o_ Q AL IL of �o�s II � flG w� m m INJ W.CJ a �• ti r r j Ed IL o_ Q AL Salse Cascade Single 9-1/2" BCI® 5000-1.7 DF PA�SEU __ _ J01 (Joist) BC CALC@) Member Report Dry 11 span I No cant. 116 OCS I Repetitive I Glued & nailed December 2, 2021 111:06:25 Build 8104 Job name: File name: Address: Description. City, State, Zip: Specifier: Customer: Designer: Harold Hahnenkratt Code reports: ESR -1336 Company: Precise Engineering Inc Span 1 Depth 14.6 % Allow % Allow Bearing Supports Dim, LxW Value Support Member Materlal 131 Wall/Plate 3-112" x 2" 496 lbs 17.5% 44.1% Hem -Fir B2 Wall/Plate 3-112" x 2" 496 lbs 17.5% 44A % Hem -Fir BC FloorValue@ Summary BC FloorValue®: Subfloor: 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating: Premium Controlling Location: 06-00-00 Notes Design meets Code minimum (L1240) Total load deflection criteria. Design meets User specified (L1480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. BC CALC® analysis is based on IBC 2015. Composite EI value based on 3/4" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. Calculations assume member is fully braced. Page 1 of 1 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability For a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installatdon Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (8017)232-0788 before installation. BC CALCO, BC FRAMEROD, AJSTm, ALLJOISTO , BC RIM BOARD-, BCIR) , BOISE GLULAMTm, BC FloorValue® , VERSA -LAMS, VERSA -RIM PLUSC , 12.00.00 B1 B2 Total Horizontal Product Length =12-00-00 Reaction Summary (Down 1 Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live B1, 3-112" 40010 9610 ---- - — B2, 3-1f2" 40010 9610 Load Summary Live Dead Snow Wind Roof ocs Live TagDescription Load Type Ref. Start End_ Loc. 100% 90% 115% 160% 125% 1 Standard Load Unf. Area (Ibiftz) L 00-00-00 12-00-00 Top 40 12 16 2 PART Unf. Area (Iblft�) L 00-00-00 12-00-00 Tap 10 16 Controls Summary Value %Allowable Duration Case Location Pas. Moment 1377 ft -lbs 56.0% 100% 1 08-00-00 End Reaction 496 lbs 44.1% 100% 1 00-00-00 End Shear 472 lbs 32.0% 100% 1 40-03-08 Total Load Deflection U751 (0.184") 31.9% nla 1 06-00-00 Live Load Deflection U932 (0.149") 51.5% nla 2 06-00-00 Max Deft. 0.184" 18.4% nla 1 06-00-00 Span 1 Depth 14.6 % Allow % Allow Bearing Supports Dim, LxW Value Support Member Materlal 131 Wall/Plate 3-112" x 2" 496 lbs 17.5% 44.1% Hem -Fir B2 Wall/Plate 3-112" x 2" 496 lbs 17.5% 44A % Hem -Fir BC FloorValue@ Summary BC FloorValue®: Subfloor: 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating: Premium Controlling Location: 06-00-00 Notes Design meets Code minimum (L1240) Total load deflection criteria. Design meets User specified (L1480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. BC CALC® analysis is based on IBC 2015. Composite EI value based on 3/4" thick OSB sheathing glued and nailed to member. Design based on Dry Service Condition. Calculations assume member is fully braced. Page 1 of 1 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability For a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installatdon Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (8017)232-0788 before installation. BC CALCO, BC FRAMEROD, AJSTm, ALLJOISTO , BC RIM BOARD-, BCIR) , BOISE GLULAMTm, BC FloorValue® , VERSA -LAMS, VERSA -RIM PLUSC , 13dsecascn Double 9-112" BCIn 5000-1.7 DF LASS D -11-M.. . J01 (Joist) BC CALCO Member Report Dry 11 span R No cant. 116 DCS E Repetitive I Glued & nailed December 2, 2021 16:10:28 Build 8104 Job name: File name: Address: Description: City, State, Zip: Specifier: Customer: Designer: Harold Hahnenkratt Code reports: ESR -1336 Company: Precise Engineering Inc 09-00.00 511 Total Horizontal Product Length = 09-00-00 Reaction Summary (Down 1 Uplift) (Ibs) B1, 3-112" 660/0 576/0 B21 3-112" 66010 57610 B2 Load Summary Live Dead Snow Wind Roof DCS Live Tag Description _ _ Load Type_ Ref. Start End Loc. 100% 90% 115% 160% 125% 1 Standard Load Unf. Area (lb/ft') L 00-00-00 09-00-00 Top 4D 12 16 2 PART Unf, Area (IbW) L 00-00-00 09-00-00 Top 10 16 3 WALL AND STAIRS Unf. Lin. (lb/ft) L 0000-00 09-00-00 Top 80 112 nla Controls Summary value "I"_Allowable Duration Case Location Pos. Moment 2505 ft -lbs 50.9% 100% 1 04-06-00 End Reaction 1236 lbs 54.9% 100% 1 00-00-00 End Shear 1156 lbs 39.2% 100% 1 00-03-08 Total Load Deflection U999 (0.112") Ma nla 1 04-06-00 Live Load Deflection U999 (0.06") nla nla 2 04-06-00 Max Defl. 0.112" nla nla 1 04-06-00 Span 1 Depth 10.8 % Allow % Allow Bearing Supports Dim. (LxW) _ Value Support Member Material B1 WaIYPlate 3-112" x 4" 1236 lbs 21.8% 54.9% Hem -Fir B2 WalYPlate 3-112" x 4" 1236 lbs 21.8% 54.9% Hem -Fir BC FloorValue@ Summary SC FlaarValue& Subtloor. 314" OSB, Glue + Nail Minimum Enhanced Premium Subfloor Rating: Premium Controlling Location: 04-06-00 Motes Design meets Code minimum (L1240) Total load deflection criteria. Design meets User specified (L1480) Live load deflection criteria. Design meets arbitrary (1") Maximum Total load deflection criteria. BC CALCO analysis is based on IBC 2015. Composite EI value based on 314" thick OSB sheathing glued and nailed to member. Design based on Ory Service Condition. Calculations assume member is fully braced. Page 1 of 1 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC0, BC FRAMER@ , AJST", ALLJOISTO , BC RIM BOARDTM, BCM, BOISE GLULAMTm, BC FloorValue® , VERSA -LAW, VERSA -RIM PLUS8 ,