Loading...
GEOTECHNICAL REPORT_Crystal Springs Road Short Plat_2023-0512 Geotechnical Report For Proposed Duplexes Crystal Springs Street NW Yelm, Washington 98597 Prepared For: SCJ Alliance 8730 Tallon Lane NE, Ste 200 Lacey, Was hington 98516 Prepared By: Pacific Testing & Inspection, Inc 3215 Harrison Avenue, Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6002 www.ptiinc.net May 4, 2023 PTI Project # 230006 5/4/23 TABLE OF CONTENTS 1.0 PROJECT INFORMATION ................................................................................................................ 2 2.0 SURFACE AND SUBSURFACE CONDITIONS............................................................................... 3 Surface Observations .................................................................................................................................. 3 Groundwater ........................................................................................................................................... 4 3.0 ENGINEERING ANALYSES, CONCLUSIONS & RECOMMENDATIONS ............................... 6 3.1 Building Foundation Recommendations ......................................................................................... 6 Bearing Capacity .................................................................................................................................... 6 Settlement ............................................................................................................................................... 6 Concrete Slabs-on-Grade ........................................................................................................................ 6 3.2 Earthwork Construction Recommendations ................................................................................... 7 Excavation .............................................................................................................................................. 7 Placement and Compaction of Native Soils and Engineered Fill ........................................................... 7 3.3 Parking Lot ........................................................................................................................................ 8 3.4 Erosion ................................................................................................................................................ 8 3.5 Seismic Considerations and Liquefaction ........................................................................................ 9 3.6 Surface and Subsurface Drainage .................................................................................................... 9 4.0 CLOSURE .............................................................................................................................................10 Appendix A – Test Pit Location Plan Appendix B – Soil Information Appendix C – Laboratory Analysis _____________________________________________________________________________________ Duplex Geotechnical Report Page 2 of 10 Crystal Springs Street Yelm, Washington May 4, 2023 1.0 PROJECT INFORMATION Pacific Testing and Inspection, Inc (PTI) completed this geotechnical report in support of the planned duplexes to be located on Crystal Springs Street NW in Yelm, Washington. See the Vicinity Map on the following page for a general indication of the project location. The purpose of this geotechnical investigation is to assess the surface and subsurface conditions in order to provide geotechnical recommendations that should be implemented during development. In order to fulfill the purpose of investigation, the geotechnical program completed for the proposed improvements of the project include: • Review project information provided by the project owner/ representative of the property. • Conduct a site visit to document the site conditions that may influence the construction and performance of the proposed improvements of the project. • Define general subsurface conditions of the site by reviewing geological maps and observing subsoils within geotechnical test pit excavations. • Collect bulk samples at various depths and locations. • Complete an engineering analysis supported by the planned site alterations, and the surface and subsurface conditions that were identified by the field investigation, soil testing, and applicable project research; and, • Establish conclusions based on findings, and make recommendations for foundations, earthwork construction requirements, and other considerations. Vicinity Map from Google Maps Website _____________________________________________________________________________________ Duplex Geotechnical Report Page 3 of 10 Crystal Springs Street Yelm, Washington May 4, 2023 2.0 SURFACE AND SUBSURFACE CONDITIONS Information pertaining to the existing surface and subsurface conditions for the project was gathered on April 11, 2023, by a representative with PTI. During the site visit, the type of geotechnical investigation was assessed, site features were documented that may influence construction, and site features were examined that may be influenced by construction. Specific information on field methods, sampling, field testing, general geologic conditions, specific subsurface conditions, and results from soil testing are presented in this section of the report. Applicable test pit locations are depicted on the Test Pit Location Plan provided in Appendix A of this report. Appendix B of this report includes soil information, and Appendix C contains laboratory testing results. Surface Observations The property is currently land within the vicinity of urban development in the City of Yelm. The site is accessed and adjacent to the west side Crystal Springs Street NW. The property is relatively flat to slightly sloping grades descending towards the west. Critical slopes do not appear to influence this project. Surface drainage appears to sheet flow to the west. Excessive scour, or stream bank erosion was not observed at the time of our site visit where the development is expected to occur. Yelm Creek is located well beyond the property limits to the west. Subsurface Conditions Information on subsurface conditions for the project was accomplished by examining soils within three (3) test pits extending to depths of up to 12 feet below the existing ground surface and reviewing geological maps representing the general vicinity of the project. In general, soils at the project are composed of materials from glacial advances. The geologic conditions as presented in the “Geologic Map of Washington,” compiled by J. Eric Schuster, 2002 indicates Lower Tertiary (Oligocene-Paleocene), ITs. Lower tertiary are generally sedimentary rocks, and dominantly deposited from glacial drift, including alluvium deposits. This project is located within the Puget Lowland. Typically, “lower tertiary sedimentary rocks unconformably overlie the Crescent Formation.” as revealed in the Geologic Map. Initial sedimentary rocks were formed from shale, sandstones, and coal deposits from rivers. During the Quaternary period, the Puget Lowland was covered by numerous ice sheets, with the most recent being the Fraser glacier with a peak of approximately 14,000 years ago. Upon the glacial retreat, the landscape was formed by glacial erosion glacial drift deposits. Native soils to the depth of terminous generally consist of poorly graded and well graded gravel (GP/ GW) with some sand and varying amounts of silt. According to the “Soil Survey of Thurston County,” by the United States Department of Agriculture, Soil Conservation Service, the site soils are described as Spanaway gravelly sandy loam, 110. The soil designation is depicted in the aerial photograph below, and descriptions are provided in Appendix B of this report. _____________________________________________________________________________________ Duplex Geotechnical Report Page 4 of 10 Crystal Springs Street Yelm, Washington May 4, 2023 Soil Survey From USDA Natural Resources Conservation Service Groundwater Indications of groundwater were not present within our test pits. Based on the local geology, permanent groundwater is expected to be located more than 20 feet below the proposed building pad. Soil Testing Visual classifications were performed in the field in accordance with the American Standards for Testing and Materials (ASTM) D2488. Laboratory testing was performed in order to further classify soils at selected locations and depths, and determine index and engineering properties of the soils. The soil samples obtained at the project site during the field investigation were preserved and transported for laboratory testing. The following soil tests were performed in accordance with the American Standards for Testing and Materials (ASTM): 10 Particle Size Analyses (ASTM D422) The results from our laboratory testing, performed by PTI, are provided in Appendix C of this report. _____________________________________________________________________________________ Duplex Geotechnical Report Page 5 of 10 Crystal Springs Street Yelm, Washington May 4, 2023 Infiltration Pacific Testing & Inspection, Inc (PTI) has completed three test pits on the referenced property and ten (10) sieve analysis tests on materials that were used to determine infiltration capacity for proposed stormwater management facilities. Specifically, we are providing infiltration rates based on the Soil Grain Size Analysis Method as outlined in the 2019 Stormwater Management Manual for Western Washington. The attached sieve analysis reports depict each sample source and material characteristics that we tested. Based on our laboratory results and the aforesaid drainage manual, infiltration was determined to be the following: Log10(Ksat) = -1.57+1.90D10 + 0.015D60 – 0.013D90 – 2.08ffines where, Ksat = saturated hydraulic conductivity, cm/sec D10 = soil sample 10% finer by weight, mm D60 = soil sample 60% finer by weight, mm D90 = soil sample 90% finer by weight, mm ffines = soil fraction passing #200 seive, by weight, mm Cation Exchange Capacity Water quality for this project may be achieved by the soil subgrade beneath proposed water storage areas. The Cation-Exchange Capacity (CEC) of the soils were tested by Libby Environmental, and determined to be the following: TP1 @ 4’-5’ 7.17 meq/100g TP3 @ 4’ 7.89 meq/100g TP5 @ 4’-5’ 7.50 meq/100g _____________________________________________________________________________________ Duplex Geotechnical Report Page 6 of 10 Crystal Springs Street Yelm, Washington May 4, 2023 3.0 ENGINEERING ANALYSES, CONCLUSIONS & RECOMMENDATIONS The following sections present engineering analyses, conclusions and recommendations with relation to the existing conditions and proposed improvements of the project. 3.1 Building Foundation Recommendations The recommended allowable bearing capacities and settlements as presented below, consider the expected construction as well as the field investigation results by PTI. Stepped foundations are acceptable, if warranted for this project. Continuous, isolated, or stepped foundations shall be horizontally level between the bottom of the foundation and the top of the bearing strata. The frost penetration depth is not expected to extend beyond 12 inches below the ground surface for this project under normal circumstances and anticipated design features. Bearing Capacity Existing in-situ soils for this project indicates that the structure can be established on shallow, continuous or isolated footings. Foundations shall be established on relatively undisturbed native soil. Alternatively, foundations may be constructed on selective re- compacted native soil or compacted engineered fill as described in the Earthwork Construction Recommendations Section of this report. For a bearing capacity requirement of no more than 1750 psf, a minimum continuous footing width of 16 inches shall be placed on top of undisturbed, unyielding native soils. For a columnar load of no more than 4 tons, a circular or square isolated foundation diameter or width shall be at least 24 inches. Alternatively, foundations may be constructed on engineered fill with at least 12 inches of final cover. Foundation recommendations are made available based on adherence to the remaining recommendations that are provided in this report. Alterations to the aforementioned foundation recommendations may be completed upon a site inspection by a geotechnical engineer after the foundation excavation is completed. In addition, the structural engineer may correlate bearing loads with foundation widths based on our recommendations. Settlement Total and differential settlement that a structure will undergo depends primarily on the subsurface conditions, type of structure, amount and duration of pressure exerted by the structure, reduction of pore water pressure, and in some instances, the infiltration of free moisture. Based on the expected native soil conditions, anticipated development, and construction abides by the recommendations in this report, the assumed foundation system may undergo a maximum of 1.0 inch total settlement, and a maximum differential settlement of 0.75 inch. Concrete Slabs-on-Grade Interior slabs, if utilized, should be supported on a minimum of 4 inches of compacted coarse, granular material (Retained on the U.S. Sieve #8 or greater) with less than 10% _____________________________________________________________________________________ Duplex Geotechnical Report Page 7 of 10 Crystal Springs Street Yelm, Washington May 4, 2023 finer material (U.S. Sieve #200) that is placed over undisturbed, competent native subgrade or engineered fill. The recommendations for interior concrete slabs-on-grade as presented herein are only relevant for the geotechnical application of this project. Although beyond the scope of this report, concrete slabs should also be designed for structural integrity and environmental reliability. This includes vapor barriers or moisture control for mitigating excessive moisture in the building. 3.2 Earthwork Construction Recommendations Founding material for building foundations shall consist of undisturbed native soils to the specified foundation depths. Compacted engineered fill, or selective re-compacted native soils may be used to the extents provided in this Earthwork Construction Recommendations Section. The following recommendations include excavations, subgrade preparation, type of fill, and placement of fill for building foundations. Excavation Excavation is recommended to remove fill, any excessive organic content or other deleterious material, if present, beneath foundations and to achieve appropriate foundation depth. Additional sub-excavation will be required for this project if the soils below the required foundation depth are loose, saturated, not as described in this report, or otherwise incompetent due to inappropriate land disturbing, or excessive water trapped within foundation excavations prior to foundation construction. All soils below the bottom of the excavation shall be competent, and relatively undisturbed or properly compacted fill. If these soils are disturbed or deemed incompetent, re-compaction of these soils below the anticipated footing depth is necessary. Excavations shall be completely dewatered, compacted, and suitable before placement of additional native soil, engineered fill or structural concrete. Placement and Compaction of Native Soils and Engineered Fill For engineered fill or disturbed native soils that will be utilized as fill material directly beneath foundations, observation and/ or geotechnical testing is required prior to foundation construction. The following placement and compaction requirements are necessary. For disturbed native soils or engineered fill beneath foundations, limits of compacted or re-compacted fill shall extend laterally from the bottom edge of the foundation at a rate of one horizontal foot for each foot of compacted or re-compacted fill depth beneath the foundation. See the illustration below. _____________________________________________________________________________________ Duplex Geotechnical Report Page 8 of 10 Crystal Springs Street Yelm, Washington May 4, 2023 Both engineered fill and native soils used as compacted fill should be free of roots and other organics, rocks over 6 inches in size, or any other deleterious matter. Because of moisture sensitivity, importing and compacting engineered fill may be more economical than compacting disturbed native soils. Import material or native soils free of organics may be used as engineered fill. If import material is utilized as structural fill material for placement in building pad and parking lot areas meet the current Washington State Department of Transportation Standard Specification for Road, Bridge and Municipal Construction (WSDOT), Section 9-03(14), for Gravel Borrow. The material should be placed per the recommendation in section 2- 06 of WSDOT for sub-grade. Material should be placed in 8-inch vertical lifts and compacted with a vibratory smooth drum roller to achieve 95% of the (ASTM D1557) modified proctor. Each lift surface should be adequately maintained during construction in order to achieve acceptable compaction and inter-lift bonding. Temporary earth cuts and temporary fill slopes exceeding 4 feet in height should be limited to a slope of 2:1 (horizontal: vertical). Utility trenches or other confined excavations exceeding 4 feet should conform to OSHA safety regulations. Permanent cut and fill slopes shall be limited to a slope of 2:1, unless otherwise approved by an engineer. 3.3 Parking Lot Surface course and base course for parking lot construction should meet the requirements of 9- 03.9(03) and 9-03(10) from the Washington State Department of Transportation Standard Specifications for Road, Bridge and Municipal Construction. Furthermore, the base material shall be placed and compacted per the recommendations in this report. The base material should be above structural fill and prepared subgrade after underlying unsuitable subgrade is removed, if any. The aforesaid recommendations will yield the best product and provide a standard pavement design life. 3.4 Erosion Based on the USCS description of the project soils, the surface soils are considered moderately erodible near the surface. According to the Resource Map from the Washington State DNR, the project is not within terrain labeled ‘highly erodible.’ It is our opinion that standard erosion control recommendations within the stormwater management plan is sufficient for the development of this project, and special erosion control requirements are not needed. _____________________________________________________________________________________ Duplex Geotechnical Report Page 9 of 10 Crystal Springs Street Yelm, Washington May 4, 2023 3.5 Seismic Considerations and Liquefaction Soils immediately below the expected foundation depth for this project are generally Type C, corresponding to the International Building Code (IBC) soil profiles. According to the IBC, the regional seismic zone is 3 for this project. The estimated peak ground acceleration ranges from 0.50g to 0.60g. This estimation is based on the United States Geological Survey (USGS) National Seismic Hazard project in which there is an estimated 2% probability of exceedance within the next 50 years. The potential for liquefaction is believed to be low for this project. This is based, in part, on the subsurface conditions such as soil characteristics and the lack of a permanent shallow water table. Subgrade characteristics that particularly contribute to problems caused from liquefaction include submerged, confined, poorly graded granular soils (i.e. gravel, sand, silt). Although gravel- and silt-sized soil particles could be problematic, fine and medium grained sands are typically subjected to these types of seismic hazards. No significant saturated sand stratifications are anticipated to be within the upper 50 feet of the subsoil for this project. 3.6 Surface and Subsurface Drainage Positive drainage should be provided in the final design for all planned residential buildings. Drainage shall include sloping the ground surface, driveways and sidewalks away from the project structures. All constructed surface and subsurface drains should be adequately maintained during the life of the structure. If drainage problems occur during or after construction, additional engineered water mitigation will be required immediately. This may include a combination of swales, berms, drainpipes, infiltration facilities, or outlet protection in order to divert water away from the structures to an appropriate protected discharge area. Leakage of water pipes, both drainage and supply lines, shall be prevented at all times. Infiltration is allowable for this project for any stormwater management runoff. All native soils on the property may utilize an infiltration rate of 24 in/hr as previously calculated in this report. The stormwater engineer shall review our investigated soil depths in this report to achieve proper infiltration facility depth. _____________________________________________________________________________________ Duplex Geotechnical Report Page 10 of 10 Crystal Springs Street Yelm, Washington May 4, 2023 4.0 CLOSURE Based on the project information provided by the owner, the proposed development, and site conditions as presented in this report, it is our opinion that additional geotechnical studies are not required to further evaluate this project. If deep foundations are considered in lieu of fill replacement, further recommendations by PTI are required. Due to the inherent natural variations of the soil stratification and the nature of the geotechnical subsurface exploration, there is always a possibility that soil conditions encountered during construction are different than those described in this report. Therefore, it is recommended that a qualified engineer observes and documents the construction, or PTI is promptly notified if project and subsurface conditions found on-site are not as presented in this report so that we can re- evaluate our recommendations. PTI did not perform environmental studies on this site. The determination of wetlands, hazardous substances, or other environmental concerns was beyond the scope of this geotechnical report. This report presents geotechnical design guidelines, and is intended only for the owner, or owners’ representative, and location of project described herein. This report should not be used to dictate construction procedures or relieve the contractor of his responsibility. The recommendations provided in this report are valid for the proposed development at the issuance date of this report. Changes to the site other than the expected development, changes to neighboring properties, changes to ordinances or regulatory codes, or broadening of accepted geotechnical standards may affect the long-term conclusions and recommendations presented in this report. Please contact PTI if you have any questions, comments, or require additional information. Sincerely, Pacific Testing & Inspection, Inc. Michael Staten, P.E. Engineer 5/4/23 APPENDIX A TEST PIT LOCATION PLAN tj -0 c70 00 m� m o t:1 -0 v x0 cm w r r 0 d m� mo x v, d m� ro m) tj -u c;ou Uo r--u m� M o x v) cn r tj m� m CRYSTAL SPRINGS STREET NW (/1 oZ"Q2 ;D r< � O o � V 3 W L r wD=..m 1 m 1 ;o m W £� rrn 00 m f�Tl ro M - NNZZ � 02 r C3 C:] 3 Z C Q° 00 Z mr 0 z.. W d O Z n Zm� rri rJ o D D m � i c m - coZ Fy O Z Y Z £ mro x(n r CZ1 2 D o Z _ _q Ln m 1 Thurston County Area, Washington 110—Spanaway gravelly sandy loam, 0 to 3 percent slopes Map Unit Setting National map unit symbol: 2ndb6 Elevation: 330 to 1,310 feet Mean annual precipitation: 35 to 65 inches Mean annual air temperature: 50 degrees F Frost-free period: 150 to 200 days Farmland classification: Prime farmland if irrigated Map Unit Composition Spanaway and similar soils:100 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Spanaway Setting Landform:Terraces, outwash plains Parent material:Volcanic ash over gravelly outwash Typical profile H1 - 0 to 15 inches: gravelly sandy loam H2 - 15 to 20 inches: very gravelly loam H3 - 20 to 60 inches: extremely gravelly sand Properties and qualities Slope:0 to 3 percent Depth to restrictive feature:More than 80 inches Drainage class:Somewhat excessively drained Capacity of the most limiting layer to transmit water (Ksat):High (1.98 to 5.95 in/hr) Depth to water table:More than 80 inches Frequency of flooding:None Frequency of ponding:None Available water supply, 0 to 60 inches: Low (about 3.8 inches) Interpretive groups Land capability classification (irrigated): 3s Land capability classification (nonirrigated): 3s Hydrologic Soil Group: A Ecological site: R002XA006WA - Puget Lowlands Prairie Forage suitability group: Droughty Soils (G002XS401WA) Other vegetative classification: Droughty Soils (G002XS401WA) Map Unit Description: Spanaway gravelly sandy loam, 0 to 3 percent slopes---Thurston County Area, Washington Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 5/5/2023 Page 1 of 2 Hydric soil rating: No Data Source Information Soil Survey Area: Thurston County Area, Washington Survey Area Data: Version 16, Sep 8, 2022 Map Unit Description: Spanaway gravelly sandy loam, 0 to 3 percent slopes---Thurston County Area, Washington Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 5/5/2023 Page 2 of 2 APPENDIX B TEST PIT LOGS Pacific Testing & Inspection Inc. 3215 Harrison Avenue, Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6002 All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Rev. 6/6/15 Revision 1 LOG OF TEST PIT Project No.: 230006 Project Name: Crystal Springs Client: SCJ Alliance Date: 4/11/23 Test Pit No.: 1 Location: NE Infiltration Diameter: Logged By: TB Depth of Water: None Date Checked: 4/11/23 Depth of Caving: Elev. Or Depth Lab # USCS Description Remarks Moisture (%) 0-1’ GM 10YR 4/3 Dark Brown Fine to coarse sandy gravel w/ silt Moist, loose, organics 1’-3’ GP 10YR 5/6 Yellowish Brown gravel w/ fine to coarse sand & some silt Moist, dense, <8”, <40%, rounded 3’-5’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, dense, <10”, <40%, rounded 5’- 12’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, very dense, <12”, <30% 12 GP Test pit terminated Same, gets cleaner Reported by: Tim Barney ICC geotechnical Inspector Reviewed by: Michael Staten, PE Pacific Testing & Inspection Inc. 3215 Harrison Avenue, Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6002 All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Rev. 6/6/15 Revision 1 LOG OF TEST PIT Project No.: 230006 Project Name: Crystal Springs Client: SCJ Alliance Date: 4/11/23 Test Pit No.: 2 Location: SE Infiltration Diameter: Logged By: TB Depth of Water: None Date Checked: 4/11/23 Depth of Caving: Elev. Or Depth Lab # USCS Description Remarks Moisture (%) 0-2’ GM 10YR 4/3 Dark Brown Fine to coarse sandy gravel w/ silt Moist, loose, organics, Fill 2’-5’ GP 10YR 5/6 Yellowish Brown gravel w/ fine to coarse sand & some silt Moist, dense, <8”, <40%, rounded 5’-7’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, dense, <10”, <50%, rounded 7’- 12’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, very dense, <6”, <60% 12 GP Test pit terminated Same, gets cleaner Reported by: Tim Barney ICC geotechnical Inspector Reviewed by: Michael Staten, PE Pacific Testing & Inspection Inc. 3215 Harrison Avenue, Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6002 All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Rev. 6/6/15 Revision 1 LOG OF TEST PIT Project No.: 230006 Project Name: Crystal Springs Client: SCJ Alliance Date: 4/11/23 Test Pit No.: 3 Location: S Center Infiltration Diameter: Logged By: TB Depth of Water: None Date Checked: 4/11/23 Depth of Caving: Elev. Or Depth Lab # USCS Description Remarks Moisture (%) 0-2’ GM 10YR 4/3 Dark Brown Fine to coarse sandy gravel w/ silt Moist, loose, organics, <10”, <40% 2’-5’ GP 10YR 5/6 Yellowish Brown gravel w/ fine to coarse sand & some silt Moist, dense, <12”, <40%, rounded 5’-7’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, dense, <6”, <40%, rounded 7’- 12’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, very dense, <8”, <50% 12 GP Test pit terminated Same, gets cleaner Reported by: Tim Barney ICC geotechnical Inspector Reviewed by: Michael Staten, PE Pacific Testing & Inspection Inc. 3215 Harrison Avenue, Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6002 All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Rev. 6/6/15 Revision 1 LOG OF TEST PIT Project No.: 230006 Project Name: Crystal Springs Client: SCJ Alliance Date: 4/11/23 Test Pit No.: 4 Location: SW Building Pad Diameter: Logged By: TB Depth of Water: None Date Checked: 4/11/23 Depth of Caving: Elev. Or Depth Lab # USCS Description Remarks Moisture (%) 0-2’ GM 10YR 4/3 Dark Brown Fine to coarse sandy gravel w/ silt Moist, loose, organics, <3”, <20% 2’-3’ GP 10YR 5/6 Yellowish Brown gravel w/ fine to coarse sand & some silt Moist, dense, <6”, <30%, rounded 3’-9’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, dense, <10”, <30%, rounded 9’- 12’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, very dense, <10”, <40% 12 GP Test pit terminated Same, gets cleaner Reported by: Tim Barney ICC geotechnical Inspector Reviewed by: Michael Staten, PE Pacific Testing & Inspection Inc. 3215 Harrison Avenue, Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6002 All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Rev. 6/6/15 Revision 1 LOG OF TEST PIT Project No.: 230006 Project Name: Crystal Springs Client: SCJ Alliance Date: 4/11/23 Test Pit No.: 5 Location: N. Center Infiltration Diameter: Logged By: TB Depth of Water: None Date Checked: 4/11/23 Depth of Caving: Elev. Or Depth Lab # USCS Description Remarks Moisture (%) 0-2’ GM 10YR 4/3 Dark Brown Fine to coarse sandy gravel w/ silt Moist, loose, organics, <5”, <30% 2’-3’ GP 10YR 5/6 Yellowish Brown gravel w/ fine to coarse sand & some silt Moist, dense, <8”, <40%, rounded 3’-7’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, dense, <12”, <40%, rounded 7’- 12’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, very dense, <8”, <40% 12 GP Test pit terminated Same, gets cleaner Reported by: Tim Barney ICC geotechnical Inspector Reviewed by: Michael Staten, PE Pacific Testing & Inspection Inc. 3215 Harrison Avenue, Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6002 All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Rev. 6/6/15 Revision 1 LOG OF TEST PIT Project No.: 230006 Project Name: Crystal Springs Client: SCJ Alliance Date: 4/11/23 Test Pit No.: 6 Location: N.W Building Pad Diameter: Logged By: TB Depth of Water: None Date Checked: 4/11/23 Depth of Caving: Elev. Or Depth Lab # USCS Description Remarks Moisture (%) 0-2’ GM 10YR 4/3 Dark Brown Fine to coarse sandy gravel w/ silt Moist, loose, organics, <10”, <20% 2’-3’ GP 10YR 5/6 Yellowish Brown gravel w/ fine to coarse sand & some silt Moist, dense, <10”, <40%, rounded 3’-7’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, dense, <8”, <50%, rounded 7’- 12’ GP 10YR ¾ Dark Yellowish Brown poorly graded gravel w/ fine to coarse sand, trace silt & cobble Moist, very dense, <6”, <30% 12 GP Test pit terminated Same, gets cleaner Reported by: Tim Barney ICC geotechnical Inspector Reviewed by: Michael Staten, PE APPENDIX C LABORATORY ANALYSIS Pacific Testing & Inspection Inc. 3215 Harrison Avenue Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6022 ASTM C-136 Sieve Report ASTM D-4318 Date :4/11/2023 D10 =0.79 USCS Classification % Gravel % Sand Sample #:23-063 D30 =6.55 GP, Poorly graded Gravel with Sand 73.8%25.2% Source:TP1 @ 1'D60 =17.16 Specifications Color: Project #:230006 CC =3.16 No Specs 10YR3/3 Dk. Brn Project:Crystal Springs CU =21.64 Sample Meets Specs % Silt & Clay Client:SCJ Alliance Liquid Limit=0.0%n/a 1.1% Tested By:TB Plastic Limit=0.0%Fineness Modulus Date Tested:4/14/2023 Plasticity Index=0.0%6.91 Coarse Actual Interpolated Fines Actual Interpolated Section Cumulative Cumulative Section Cumulative Cumulative Sieve Size Percent Percent Specs Specs Sieve Size Percent Percent Specs Specs US Metric Passing Passing Max Min US Metric Passing Passing Max Min 6.00"150.00 100%#4 4.750 26%26% 4.00"100.00 100%100%#8 2.360 21%21% 3.00"75.00 69%69%#10 2.000 20%20% 2.50"63.00 68%#16 1.180 16%16% 2.00"50.00 67%#20 0.850 11% 1.75"45.00 66%#30 0.600 7%7% 1.50"37.50 66%#40 0.425 4%4% 1.25"31.50 65%#50 0.300 3%3% 1.00"25.00 65%#60 0.250 2% 7/8"22.40 64%#80 0.180 2% 3/4"19.00 64%64%#100 0.150 2%2% 5/8"16.00 57%57%#140 0.106 1% 1/2"12.50 45%45%#170 0.090 1% 3/8"9.50 37%37%#200 0.075 1.1%1.1% 1/4"6.30 29%29%#270 0.053 #4 4.75 26%26% Copyright Spears Engineering & Technical Services PS, 1996-2005 Comments: Reviewed by: Tim Barney All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0.0010.010.11101001000% Passing by WeightGrain Size in Millimeters U.S. Standard Sieve Opening in U.S. Standard Sieve Hydrometer Cobble Gravel Sands Silt Coars Fine Coarse Medium Fine Clays 0%#41 10 1620¾⅜30 50 10 20344020½ 20% 50% 60% 70% 10% 80% 30% 40% 90% 100%% Retained by WeightRev. 6/6/15 Revision 6 Pacific Testing & Inspection Inc. 3215 Harrison Avenue Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6022 ASTM C-136 Sieve Report ASTM D-4318 Date :4/11/2023 D10 =0.83 USCS Classification % Gravel % Sand Sample #:23-064 D30 =11.20 GP, Poorly graded Gravel with Sand 80.4%18.3% Source:TP1 @ 3'D60 =39.95 Specifications Color: Project #:230006 CC =3.77 No Specs 10YR3/4 Dk. Yell. Brn Project:Crystal Springs CU =47.96 Sample Meets Specs % Silt & Clay Client:SCJ Alliance Liquid Limit=0.0%n/a 1.3% Tested By:TB Plastic Limit=0.0%Fineness Modulus Date Tested:4/14/2023 Plasticity Index=0.0%7.09 Coarse Actual Interpolated Fines Actual Interpolated Section Cumulative Cumulative Section Cumulative Cumulative Sieve Size Percent Percent Specs Specs Sieve Size Percent Percent Specs Specs US Metric Passing Passing Max Min US Metric Passing Passing Max Min 6.00"150.00 100%#4 4.750 20%20% 4.00"100.00 100%#8 2.360 16%16% 3.00"75.00 100%100%#10 2.000 15%15% 2.50"63.00 79%79%#16 1.180 13%13% 2.00"50.00 64%64%#20 0.850 10% 1.75"45.00 62%#30 0.600 8%8% 1.50"37.50 59%#40 0.425 4%4% 1.25"31.50 57%#50 0.300 3%3% 1.00"25.00 55%55%#60 0.250 3% 7/8"22.40 50%#80 0.180 2% 3/4"19.00 44%44%#100 0.150 2%2% 5/8"16.00 39%39%#140 0.106 2% 1/2"12.50 32%32%#170 0.090 1% 3/8"9.50 27%27%#200 0.075 1.3%1.3% 1/4"6.30 22%22%#270 0.053 #4 4.75 20%20% Copyright Spears Engineering & Technical Services PS, 1996-2005 Comments: Reviewed by: Tim Barney All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0.0010.010.11101001000% Passing by WeightGrain Size in Millimeters U.S. Standard Sieve Opening in U.S. Standard Sieve Hydrometer Cobble Gravel Sands Silt Coars Fine Coarse Medium Fine Clays 0%#41 10 1620¾⅜30 50 10 20344020½ 20% 50% 60% 70% 10% 80% 30% 40% 90% 100%% Retained by WeightRev. 6/6/15 Revision 6 Pacific Testing & Inspection Inc. 3215 Harrison Avenue Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6022 ASTM C-136 Sieve Report ASTM D-4318 Date :4/11/2023 D10 =0.31 USCS Classification % Gravel % Sand Sample #:23-065 D30 =0.81 GP-GM, Poorly graded Gravel with Silt and Sand47.4%47.1% Source:TP1 @ 7'D60 =8.51 Specifications Color: Project #:230006 CC =0.25 No Specs 10YR3/4 Dk. Yell. Brn Project:Crystal Springs CU =27.70 Sample Meets Specs % Silt & Clay Client:SCJ Alliance Liquid Limit=0.0%n/a 5.6% Tested By:TB Plastic Limit=0.0%Fineness Modulus Date Tested:4/14/2023 Plasticity Index=0.0%4.82 Coarse Actual Interpolated Fines Actual Interpolated Section Cumulative Cumulative Section Cumulative Cumulative Sieve Size Percent Percent Specs Specs Sieve Size Percent Percent Specs Specs US Metric Passing Passing Max Min US Metric Passing Passing Max Min 6.00"150.00 100%#4 4.750 53%53% 4.00"100.00 100%#8 2.360 46%46% 3.00"75.00 100%#10 2.000 45%45% 2.50"63.00 100%#16 1.180 40%40% 2.00"50.00 100%#20 0.850 31% 1.75"45.00 100%#30 0.600 24%24% 1.50"37.50 100%100%#40 0.425 15%15% 1.25"31.50 90%#50 0.300 10%10% 1.00"25.00 80%80%#60 0.250 9% 7/8"22.40 78%#80 0.180 7% 3/4"19.00 77%#100 0.150 7%7% 5/8"16.00 75%75%#140 0.106 6% 1/2"12.50 69%69%#170 0.090 6% 3/8"9.50 62%62%#200 0.075 5.6%5.6% 1/4"6.30 56%56%#270 0.053 #4 4.75 53%53% Copyright Spears Engineering & Technical Services PS, 1996-2005 Comments: Reviewed by: Tim Barney All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0.0010.010.11101001000% Passing by WeightGrain Size in Millimeters U.S. Standard Sieve Opening in U.S. Standard Sieve Hydrometer Cobble Gravel Sands Silt Coars Fine Coarse Medium Fine Clays 0%#41 10 1620¾⅜30 50 10 20344020½ 20% 50% 60% 70% 10% 80% 30% 40% 90% 100%% Retained by WeightRev. 6/6/15 Revision 6 Pacific Testing & Inspection Inc. 3215 Harrison Avenue Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6022 ASTM C-136 Sieve Report ASTM D-4318 Date :4/11/2023 D10 =0.81 USCS Classification % Gravel % Sand Sample #:23-066 D30 =6.09 GP, Poorly graded Gravel with Sand 74.5%22.7% Source:TP2 @ 3'D60 =14.53 Specifications Color: Project #:230006 CC =3.16 No Specs 10YR3/3 Dk. Brn, Project:Crystal Springs CU =17.96 Sample Meets Specs % Silt & Clay Client:SCJ Alliance Liquid Limit=0.0%n/a 2.9% Tested By:TB Plastic Limit=0.0%Fineness Modulus Date Tested:4/14/2023 Plasticity Index=0.0%6.12 Coarse Actual Interpolated Fines Actual Interpolated Section Cumulative Cumulative Section Cumulative Cumulative Sieve Size Percent Percent Specs Specs Sieve Size Percent Percent Specs Specs US Metric Passing Passing Max Min US Metric Passing Passing Max Min 6.00"150.00 100%#4 4.750 26%26% 4.00"100.00 100%#8 2.360 19%19% 3.00"75.00 100%#10 2.000 18%18% 2.50"63.00 100%#16 1.180 14%14% 2.00"50.00 100%#20 0.850 10% 1.75"45.00 100%#30 0.600 8%8% 1.50"37.50 100%100%#40 0.425 6%6% 1.25"31.50 95%#50 0.300 4%4% 1.00"25.00 90%90%#60 0.250 4% 7/8"22.40 83%#80 0.180 4% 3/4"19.00 74%74%#100 0.150 4%4% 5/8"16.00 66%66%#140 0.106 3% 1/2"12.50 51%51%#170 0.090 3% 3/8"9.50 39%39%#200 0.075 2.9%2.9% 1/4"6.30 31%31%#270 0.053 #4 4.75 26%26% Copyright Spears Engineering & Technical Services PS, 1996-2005 Comments: Reviewed by: Tim Barney All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0.0010.010.11101001000% Passing by WeightGrain Size in Millimeters U.S. Standard Sieve Opening in U.S. Standard Sieve Hydrometer Cobble Gravel Sands Silt Coars Fine Coarse Medium Fine Clay 0%#41 10 1620¾⅜30 50 10 20344020½ 20% 50% 60% 70% 10% 80% 30% 40% 90% 100%% Retained by WeightRev. 6/6/15 Revision 6 Pacific Testing & Inspection Inc. 3215 Harrison Avenue Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6022 ASTM C-136 Sieve Report ASTM D-4318 Date :4/11/2023 D10 =0.95 USCS Classification % Gravel % Sand Sample #:23-067 D30 =8.94 GP, Poorly graded Gravel with Sand 79.2%18.7% Source:TP2 @ 5'D60 =19.29 Specifications Color: Project #:230006 CC =4.35 No Specs 10YR2/2 V. Dk. Brn, Project:Crystal Springs CU =20.24 Sample Meets Specs % Silt & Clay Client:SCJ Alliance Liquid Limit=0.0%n/a 2.1% Tested By:TB Plastic Limit=0.0%Fineness Modulus Date Tested:4/14/2023 Plasticity Index=0.0%6.62 Coarse Actual Interpolated Fines Actual Interpolated Section Cumulative Cumulative Section Cumulative Cumulative Sieve Size Percent Percent Specs Specs Sieve Size Percent Percent Specs Specs US Metric Passing Passing Max Min US Metric Passing Passing Max Min 6.00"150.00 100%#4 4.750 21%21% 4.00"100.00 100%#8 2.360 16%16% 3.00"75.00 100%#10 2.000 15%15% 2.50"63.00 100%100%#16 1.180 12%12% 2.00"50.00 91%91%#20 0.850 9% 1.75"45.00 89%#30 0.600 7%7% 1.50"37.50 85%#40 0.425 5%5% 1.25"31.50 82%#50 0.300 4%4% 1.00"25.00 80%80%#60 0.250 3% 7/8"22.40 71%#80 0.180 3% 3/4"19.00 59%59%#100 0.150 3%3% 5/8"16.00 53%53%#140 0.106 2% 1/2"12.50 40%40%#170 0.090 2% 3/8"9.50 31%31%#200 0.075 2.1%2.1% 1/4"6.30 24%24%#270 0.053 #4 4.75 21%21% Copyright Spears Engineering & Technical Services PS, 1996-2005 Comments: Reviewed by: Tim Barney All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0.0010.010.11101001000% Passing by WeightGrain Size in Millimeters U.S. Standard Sieve Opening in U.S. Standard Sieve Hydrometer Cobble Gravel Sands Silt Coars Fine Coarse Medium Fine Clay 0%#41 10 1620¾⅜30 50 10 20344020½ 20% 50% 60% 70% 10% 80% 30% 40% 90% 100%% Retained by WeightRev. 6/6/15 Revision 6 Pacific Testing & Inspection Inc. 3215 Harrison Avenue Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6022 ASTM C-136 Sieve Report ASTM D-4318 Date :4/11/2023 D10 =0.56 USCS Classification % Gravel % Sand Sample #:23-068 D30 =5.68 GP-GM, Poorly graded Gravel with Silt and Sand73.1%21.9% Source:TP2 @ 7'D60 =16.79 Specifications Color: Project #:230006 CC =3.42 No Specs 10YR3/4 Dk. Yellow. Brn. Project:Crystal Springs CU =29.90 Sample Meets Specs % Silt & Clay Client:SCJ Alliance Liquid Limit=0.0%n/a 5.1% Tested By:TB Plastic Limit=0.0%Fineness Modulus Date Tested:4/14/2023 Plasticity Index=0.0%6.27 Coarse Actual Interpolated Fines Actual Interpolated Section Cumulative Cumulative Section Cumulative Cumulative Sieve Size Percent Percent Specs Specs Sieve Size Percent Percent Specs Specs US Metric Passing Passing Max Min US Metric Passing Passing Max Min 6.00"150.00 100%#4 4.750 27%27% 4.00"100.00 100%#8 2.360 20%20% 3.00"75.00 100%100%#10 2.000 19%19% 2.50"63.00 88%88%#16 1.180 15%15% 2.00"50.00 83%#20 0.850 13% 1.75"45.00 82%#30 0.600 10%10% 1.50"37.50 79%#40 0.425 8%8% 1.25"31.50 77%#50 0.300 7%7% 1.00"25.00 75%75%#60 0.250 7% 7/8"22.40 71%#80 0.180 6% 3/4"19.00 67%67%#100 0.150 6%6% 5/8"16.00 58%58%#140 0.106 5% 1/2"12.50 50%50%#170 0.090 5% 3/8"9.50 41%41%#200 0.075 5.1%5.1% 1/4"6.30 32%32%#270 0.053 #4 4.75 27%27% Copyright Spears Engineering & Technical Services PS, 1996-2005 Comments: Reviewed by: Tim Barney All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0.0010.010.11101001000% Passing by WeightGrain Size in Millimeters U.S. Standard Sieve Opening in U.S. Standard Sieve Hydrometer Cobble Gravel Sands Silt Coars Fine Coarse Medium Fine Clay 0%#41 10 1620¾⅜30 50 10 20344020½ 20% 50% 60% 70% 10% 80% 30% 40% 90% 100%% Retained by WeightRev. 6/6/15 Revision 6 Pacific Testing & Inspection Inc. 3215 Harrison Avenue Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6022 ASTM C-136 Sieve Report ASTM D-4318 Date :4/11/2023 D10 =0.45 USCS Classification % Gravel % Sand Sample #:23-069 D30 =3.27 GW, Well-graded Gravel with Sand 66.0%30.0% Source:TP2 @ 10'D60 =18.37 Specifications Color: Project #:230006 CC =1.29 No Specs 10YR3/4 Dk. Yellow. Brn. Project:Crystal Springs CU =40.71 Sample Meets Specs % Silt & Clay Client:SCJ Alliance Liquid Limit=0.0%n/a 4.0% Tested By:TB Plastic Limit=0.0%Fineness Modulus Date Tested:4/14/2023 Plasticity Index=0.0%6.04 Coarse Actual Interpolated Fines Actual Interpolated Section Cumulative Cumulative Section Cumulative Cumulative Sieve Size Percent Percent Specs Specs Sieve Size Percent Percent Specs Specs US Metric Passing Passing Max Min US Metric Passing Passing Max Min 6.00"150.00 100%#4 4.750 34%34% 4.00"100.00 100%#8 2.360 28%28% 3.00"75.00 100%#10 2.000 26%26% 2.50"63.00 100%100%#16 1.180 22%22% 2.00"50.00 85%85%#20 0.850 17% 1.75"45.00 84%#30 0.600 14%14% 1.50"37.50 81%#40 0.425 9%9% 1.25"31.50 79%#50 0.300 7%7% 1.00"25.00 77%77%#60 0.250 6% 7/8"22.40 70%#80 0.180 5% 3/4"19.00 61%61%#100 0.150 5%5% 5/8"16.00 55%55%#140 0.106 4% 1/2"12.50 47%47%#170 0.090 4% 3/8"9.50 44%44%#200 0.075 4.0%4.0% 1/4"6.30 38%38%#270 0.053 #4 4.75 34%34% Copyright Spears Engineering & Technical Services PS, 1996-2005 Comments: Reviewed by: Tim Barney All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0.0010.010.11101001000% Passing by WeightGrain Size in Millimeters U.S. Standard Sieve Opening in U.S. Standard Sieve Hydrometer Cobble Gravel Sands Silt Coars Fine Coarse Medium Fine Clay 0%#41 10 1620¾⅜30 50 10 20344020½ 20% 50% 60% 70% 10% 80% 30% 40% 90% 100%% Retained by WeightRev. 6/6/15 Revision 6 Pacific Testing & Inspection Inc. 3215 Harrison Avenue Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6022 ASTM C-136 Sieve Report ASTM D-4318 Date :4/11/2023 D10 =0.47 USCS Classification % Gravel % Sand Sample #:23-070 D30 =3.46 GW, Well-graded Gravel with Sand 66.7%29.4% Source:TP3 @ 7'D60 =18.82 Specifications Color: Project #:230006 CC =1.36 No Specs 10YR3/4 Dk. Yellow. Brn. Project:Crystal Springs CU =40.44 Sample Meets Specs % Silt & Clay Client:SCJ Alliance Liquid Limit=0.0%n/a 3.9% Tested By:TB Plastic Limit=0.0%Fineness Modulus Date Tested:4/14/2023 Plasticity Index=0.0%6.15 Coarse Actual Interpolated Fines Actual Interpolated Section Cumulative Cumulative Section Cumulative Cumulative Sieve Size Percent Percent Specs Specs Sieve Size Percent Percent Specs Specs US Metric Passing Passing Max Min US Metric Passing Passing Max Min 6.00"150.00 100%#4 4.750 33%33% 4.00"100.00 100%#8 2.360 27%27% 3.00"75.00 100%#10 2.000 26%26% 2.50"63.00 100%100%#16 1.180 21%21% 2.00"50.00 84%84%#20 0.850 16% 1.75"45.00 80%#30 0.600 13%13% 1.50"37.50 75%75%#40 0.425 9%9% 1.25"31.50 73%#50 0.300 7%7% 1.00"25.00 71%71%#60 0.250 6% 7/8"22.40 66%#80 0.180 5% 3/4"19.00 60%60%#100 0.150 5%5% 5/8"16.00 52%52%#140 0.106 4% 1/2"12.50 47%47%#170 0.090 4% 3/8"9.50 43%43%#200 0.075 3.9%3.9% 1/4"6.30 37%37%#270 0.053 #4 4.75 33%33% Copyright Spears Engineering & Technical Services PS, 1996-2005 Comments: Reviewed by: Tim Barney All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0.0010.010.11101001000% Passing by WeightGrain Size in Millimeters U.S. Standard Sieve Opening in U.S. Standard Sieve Hydrometer Cobble Gravel Sands Silt Coars Fine Coarse Medium Fine Clay 0%#41 10 1620¾⅜30 50 10 20344020½ 20% 50% 60% 70% 10% 80% 30% 40% 90% 100%% Retained by WeightRev. 6/6/15 Revision 6 Pacific Testing & Inspection Inc. 3215 Harrison Avenue Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6022 ASTM C-136 Sieve Report ASTM D-4318 Date :4/11/2023 D10 =0.45 USCS Classification % Gravel % Sand Sample #:23-070 D30 =1.64 GP, Poorly graded Gravel with Sand 56.5%39.8% Source:TP3 @ 12'D60 =10.34 Specifications Color: Project #:230006 CC =0.58 No Specs 10YR3/4 Dk. Yellow. Brn. Project:Crystal Springs CU =22.90 Sample Meets Specs % Silt & Clay Client:SCJ Alliance Liquid Limit=0.0%n/a 3.7% Tested By:TB Plastic Limit=0.0%Fineness Modulus Date Tested:4/14/2023 Plasticity Index=0.0%5.26 Coarse Actual Interpolated Fines Actual Interpolated Section Cumulative Cumulative Section Cumulative Cumulative Sieve Size Percent Percent Specs Specs Sieve Size Percent Percent Specs Specs US Metric Passing Passing Max Min US Metric Passing Passing Max Min 6.00"150.00 100%#4 4.750 44%44% 4.00"100.00 100%#8 2.360 35%35% 3.00"75.00 100%#10 2.000 33%33% 2.50"63.00 100%#16 1.180 26%26% 2.00"50.00 100%#20 0.850 19% 1.75"45.00 100%#30 0.600 14%14% 1.50"37.50 100%100%#40 0.425 9%9% 1.25"31.50 97%#50 0.300 6%6% 1.00"25.00 94%94%#60 0.250 6% 7/8"22.40 91%#80 0.180 5% 3/4"19.00 87%87%#100 0.150 5%5% 5/8"16.00 74%74%#140 0.106 4% 1/2"12.50 65%65%#170 0.090 4% 3/8"9.50 58%58%#200 0.075 3.7%3.7% 1/4"6.30 49%49%#270 0.053 #4 4.75 44%44% Copyright Spears Engineering & Technical Services PS, 1996-2005 Comments: Reviewed by: Tim Barney All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0.0010.010.11101001000% Passing by WeightGrain Size in Millimeters U.S. Standard Sieve Opening in U.S. Standard Sieve Hydrometer Cobble Gravel Sands Silt Coars Fine Coarse Medium Fine Clay 0%#41 10 1620¾⅜30 50 10 20344020½ 20% 50% 60% 70% 10% 80% 30% 40% 90% 100%% Retained by WeightRev. 6/6/15 Revision 6 Pacific Testing & Inspection Inc. 3215 Harrison Avenue Centralia, WA 98531 Phone (360) 736-3922 Fax (360) 807-6022 ASTM C-136 Sieve Report ASTM D-4318 Date :4/11/2023 D10 =1.10 USCS Classification % Gravel % Sand Sample #:23-072 D30 =7.21 GW, Well-graded Gravel with Sand 77.2%21.2% Source:TP5 @ 5'D60 =17.87 Specifications Color: Project #:230006 CC =2.65 No Specs 10YR3/4 Dk. Yellow. Brn. Project:Crystal Springs CU =16.26 Sample Meets Specs % Silt & Clay Client:SCJ Alliance Liquid Limit=0.0%n/a 1.6% Tested By:TB Plastic Limit=0.0%Fineness Modulus Date Tested:4/14/2023 Plasticity Index=0.0%6.50 Coarse Actual Interpolated Fines Actual Interpolated Section Cumulative Cumulative Section Cumulative Cumulative Sieve Size Percent Percent Specs Specs Sieve Size Percent Percent Specs Specs US Metric Passing Passing Max Min US Metric Passing Passing Max Min 6.00"150.00 100%#4 4.750 23%23% 4.00"100.00 100%#8 2.360 21%21% 3.00"75.00 100%100%#10 2.000 12%12% 2.50"63.00 93%93%#16 1.180 11%11% 2.00"50.00 92%92%#20 0.850 8% 1.75"45.00 90%#30 0.600 7%7% 1.50"37.50 87%#40 0.425 4%4% 1.25"31.50 85%#50 0.300 3%3% 1.00"25.00 82%82%#60 0.250 3% 7/8"22.40 74%#80 0.180 2% 3/4"19.00 63%63%#100 0.150 2%2% 5/8"16.00 54%54%#140 0.106 2% 1/2"12.50 44%44%#170 0.090 2% 3/8"9.50 34%34%#200 0.075 1.6%1.6% 1/4"6.30 29%29%#270 0.053 #4 4.75 23%23% Copyright Spears Engineering & Technical Services PS, 1996-2005 Comments: Reviewed by: Tim Barney All results apply only to actual locations and materials tested. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0.0010.010.11101001000% Passing by WeightGrain Size in Millimeters U.S. Standard Sieve Opening in U.S. Standard Sieve Hydrometer Cobble Gravel Sands Silt Coars Fine Coarse Medium Fine Clay 0%#41 10 1620¾⅜30 50 10 20344020½ 20% 50% 60% 70% 10% 80% 30% 40% 90% 100%% Retained by WeightRev. 6/6/15 Revision 6