Loading...
AQUATIC BATH - FIRE ALARM DESIGNOWNER / TENANT AQUATIC CO PO BOX 534185 DALLAS, TX 75354 CONTACT : ROB NELSON PHONE : 360.790.6015 rnelson@aquaticbath.com FIRE ALARM CONTRACTOR FIRE PROTECTION, INC. 17410 ASH WAY, Ste 8 LYNNWOOD, WA 98037 CONTACT : DAVID MOW PHONE : 425.290.9600 david@fpiseattle.com FIRE SPRINKLER CONTRACTOR EMERALD FIRE 11021 CRAMER RD NW GIG HARBOR CONTACT : RICK WEISZ PHONE : 253.587.2056 rickw@emeraldfirellc.com AQUATIC BATH FIRE ALARM INSTALLATION SHEET #SHEET DESCRIPTION FA 0.0 PROJECT DETAILS FA 1.0 FIRE ALARM - FLOOR PLAN FA 2.0 FIRE ALARM - BATTERY CALCULATIONS & RISER DIAGRAM AUTHORITY HAVING JURISDICTION : CITY OF YELM / THURSTON COUNTY FIRE PREVENTION BUILDING CODE : 2018 WA STATE BUILDING CODE & 2018 IBC FIRE CODE : 2018 INTERNATIONAL FIRE CODE STANDARDS : 2016 NFPA 72, CITY OF YELM, THURSTON COUNTY PROPOSED USE : STORAGE BUILDING BUILDING USE AND OCCUPANCY : S (FULLY SPRINKLED) CLASSIFICATION OF SUPERVISING STATION : REMOTE SUPERVISING STATION REMOTE SUPERVISING STATION : SECURITAS, LACEY WA UL LISTED PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION INC PARCEL NUMBER : 99001005600 “” Required Fire Safety Control - System Actions 1 Storage Building Manual Fire Alarm 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 Storage Fire Sprinkler Tamper/PIV Switches AActuate Audible Alarm Signal on Storage Bldg FACPB Actuate Audible Supervisory Signal on Storage Bldg FACPC Actuate Audible Common Trouble Signal on Storage Bldg FACPD E FTransmit Fire Alarm Signal to Supervising StationG Transmit Supervisory Signal to Supervising StationH Transmit Trouble Signal to Supervising StationI J FACP Annunciation SYSTEM INPUTS SYSTEM OUTPUTS Storage Bldg FACP Smoke Detector TRBLFACentral Station Notification Storage Bldg Sprinkler Dry Flow Actuate Storage Bldg Occupant Notification DevicesSUPVTransmit Waterflow Alarm Signal to Supervising StationStorage Bldg Fire Alarm AC Power Failure Storage Bldg System Low Battery Storage Bldg Open Circuit Storage Bldg Ground Fault Storage Bldg NAC Short A NEW FULLY SPRINKLED 13,000sqf STORAGE SHED/BUILDING IS BEING BUILT NEXT TO THE EXISTING MANUFACTURING BUILDING. THE NEW STORAGE BUILDING WILL HAVE A NEW DRY SYSTEM WITH AN ELECTRIC FIRE SPRINKLER PUMP. FPI WILL BE INSTALLING A NEW ADDRESSABLE FIRE SPRINKLER MONITORING SYSTEM THAT CONSISTS OF THE FOLLOWING: (1) ADDRESSABLE FACP, (1) ADDRESSABLE MANUAL PULL-STATION, (1) ADDRESSABLE SMOKE DETECTOR, (8) ADDRESSABLE FIRE SPRINKLER MONITORING MODULES, (1) ADDRESSABLE RELAY MODULE, AND (1) OUTDOOR OCCUPANT NOTIFICATION DEVICES. PER THE AHJ (MATT RUSSELL), THE NEW STORAGE BUILDING'S FACP SHALL ACTUATE A FIRE ALARM CONDITION ON THE EXISTING FACP LOCATED IN THE MANUFACTURING BUILDING. A FIRE ALARM OR DRYFLOW SIGNAL INITIATED FROM THE NEW STORAGE BUILDING WILL ACTIVATE THE EXISTING MANUFACTURING BUILDING'S OCCUPANT NOTIFICATION DEVICES. ”” ” N Northern Pacific Rd S ENW Rhoton RdN Storage Bldg Fire Sprinkler Pump Running Mfg Bldg Fire Alarm Zone Actuated Storage Bldg Fire Sprinkler Pump AC Loss Storage Bldg Fire Sprinkler Pump Phase Rev. Storage Bldg Fire Sprinkler Pump Phase Trbl A B C D E F G H I JActuate Audible Alarm Signal on Mfg Bldg FACPActuate Mfg Bldg Occupant Notification DevicesFIRE ALARM PROJECT DETAILS FA 0.0DRAWN BY: DAVID MOW , SETNICET IV - #120904REVIEWED BY ROY L. CATS NICET IVSEATTLE FIRE DEPT. #SCP-C 9955L & I #CATS*RL022CGPROPERTY OF / ALL RIGHTS RESERVED F.P.I.DAVID MOW:DATE / DESCRIPTION SHEET NUMBER SHEET TITLE PROJECT NAME DATE:12.12.23 REVISION RECORD AQUATIC BATH801 NORTHERN PACIFIC RD SEYELM, WA 98597FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM SHEET INDEX PROJECT DESCRIPTION PROJECT CODE SUMMARY PROJECT CONTACT INFO ABBREVIATIONS USED IN THE DRAWINGS EQUIPMENT - DEVICE LEGEND PROJECT INSTALLATION NOTES SEQUENCE OF OPERATIONS VICINITY MAP SITE PLAN A B C D E F G H I J 1 2 3 DRY RISER • • •• • • • • • • • • • Ω NAC DEVICES DEVICE ID LEGEND • SLC DEVICES • • • FIRE ALARM INSTALLATION FA 1.0DRAWN BY: DAVID MOW , SETNICET IV - #120904REVIEWED BY ROY L. CATS NICET IVSEATTLE FIRE DEPT. #SCP-C 9955L & I #CATS*RL022CGPROPERTY OF / ALL RIGHTS RESERVED F.P.I.DAVID MOW:DATE / DESCRIPTION SHEET NUMBER SHEET TITLE PROJECT NAME DATE:12.12.23 REVISION RECORD AQUATIC BATH801 NORTHERN PACIFIC RD SEYELM, WA 98597FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM FIRE ALARM - FLOOR PLAN SCALE : 1/8" = 1' N • • •• •• •• ••••• •• • •EXISTING MANUFACTURING BUILDING'S FACP STORAGE BUILDING'S FACP Ω FIRE ALARM BATTERY - VOLTAGE DROP CALCULATIONS & RISER DIAGRAM FA 2.0DRAWN BY: DAVID MOW , SETNICET IV - #120904REVIEWED BY ROY L. CATS NICET IVSEATTLE FIRE DEPT. #SCP-C 9955L & I #CATS*RL022CGPROPERTY OF / ALL RIGHTS RESERVED F.P.I.DAVID MOW:DATE / DESCRIPTION SHEET NUMBER SHEET TITLE PROJECT NAME DATE:12.12.23 REVISION RECORD AQUATIC BATH801 NORTHERN PACIFIC RD SEYELM, WA 98597FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM FIRE ALARM - SINGLE LINE RISER DIAGRAM FIRE ALARM - BATTERY AND VOLTAGE DROP CALCULATIONS