Ogden, Tyler - PV Plans
THIS PROJECT COMPLIES WITH THE FOLLOWING:2018 INTERNATIONAL BUILDING CODE (IBC)2018 INTERNATIONAL RESIDENTIAL CODE (IRC)2018 INTERNATIONAL MECHANICAL CODE (IMC)2018 INTERNATIONAL PLUMBING CODE (IPC)2018 INTERNATIONAL FUEL GAS CODE (IFGC)2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC)2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC)2020 NATIONAL ELECTRICAL CODE (NEC)AS ADOPTED BY CITY OF YELMCODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:ROOF MOUNT PHOTOVOLTAIC SYSTEMPV-1SITE LOCATIONPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BARRAY AND STRUCTURAL TABLESPV-3MOUNTING DETAILSPV-3AMOUNTING DETAILSPV-4THREE LINE DIAGRAMPV-5CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7LABELSPV-7ASITE PLACARDPV-8OPTIMIZER CHARTPV-9SAFETY PLANPV-10SAFETY PLANAPPENDIXMANUFACTURER SPECIFICATION SHEETSCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACEPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROMDC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2020 NECTHE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERUTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEMSOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDSINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITATTACHED TO THE ROOF USING CONDUIT MOUNT.PV-1FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------GREG ALBRIGHTSITE LOCATION JBMS P A C I N V UM S U BSITE PLANSCALE: 3/32" = 1'-0"1ROOF LINEPROPERTY LINED R I V EW A Y (E) MAIN SERVICE PANEL(N) 17 FREEDOM FOREVER: FF-MP-BBB-400(E) UTILITY METER(N) JUNCTION BOXTOTAL ROOF AREA RIDGE SETBACK CALCS:TOTAL ROOF AREA: 2051.27 SQ FTSINGLE MODULE AREA: 21.01937947 SQ FTTOTAL NUMBER OF MODULES: 17TOTAL AREA OF MODULES: 357.33 SQ FTROOF COVERAGE: 17.42%FIRE SPRINKLERS : NOPV SYSTEM6.800 kW-DC5.000 kW-AC(N) SUB PANEL(N) SOLAREDGE SE5000H-USRGM [SI1]INVERTER WITH RAPID SHUTDOWN(N) VISIBLE LOCKABLE LABALEDDISCONNECT EATON DG221URB (OREQUIVALENT)BOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10'PV-2FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------THIS SYSTEM DESIGNED WITH:WIND SPEED: 110WIND EXPOSURE: BSNOW LOAD: 15ROOF AREA: 2051.27 SQ FTSITE PLANLEGEND:OBSTRUCTIONPIPE VENTMODULESCONDUITSETBACKMSP AC JBACDISCONNECTMSPJUNCTIONBOXINVINVERTERPMPRODUCTIONMETERCASCADIAN AVE SE GREG ALBRIGHT93'-2"5 1 ' - 1 1 "93'-2"51'-11"27'-7"4' - 4 "21'-7"3'-10" JBM S P A C I N V U M S U B PV-2AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------ROOF PLANSCALE: 1/8" = 1'-0"1FIRE ACCESSPATHWAYSMODIFIED SETBACKS PROPOSED AT RIDGE:TOTAL ARRAY AREA = 357.33 SFTOTAL ROOF AREA = 2051.27 SFTOTAL ARRAY AREA AS A % TO ROOF AREA = 17.42%17.42% < 33%(E) MAIN SERVICE PANEL(N) 17 FREEDOM FOREVER:FF-MP-BBB-400(N) SOLAREDGE SE5000H-USRGM [SI1]INVERTER(N)VISIBLE LOCKABLE LABELED AC DISCONNECT EATON DG221URB (OR EQUIVALENT)(N) JUNCTION BOXBOS WILL BE AS CLOSE AS POSSIBLE TO MSP WITHIN 10'(E) UTILITY METERNOTES:1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3.JUNCTION BOX IS MOUNTED TO THE RAIL.(N) SUB PANELROOF AREA: 2051.27 SQ FTTHIS SYSTEM DESIGNED WITH:WIND SPEED: 110WIND EXPOSURE: BSNOW LOAD: 15ROOF PLAN WITH MODULES LAYOUTLEGEND:OBSTRUCTIONPIPE VENTMODULESCONDUITSETBACKMSP AC JBACDISCONNECTMSPJUNCTIONBOXINVINVERTERPMPRODUCTIONMETERTOTAL ROOF AREA: 2051.27 SQ FTTOTAL ARRAY AREA: 357.33 SQ FTARRAY COVERAGE: 17.42%SYSTEM DISTRIBUTED WEIGHT: 2.32 LBSUNIRAC: FLASHKIT PRO POINT-LOAD: 23.66LBSGREG ALBRIGHT3'-0"3' - 0 "3'-0"3'-0"FIRE ACCESSPATHWAYS PV-2BFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------ARRAY DETAILSROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCHARRAY PITCHAZIMUTHROOF AREAARRAY AREAROOF 1172020223694.59 SQ FT357.33 SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FTROOF DETAILS:TOTAL ROOF AREA: 2051.27 SQ FTTOTAL ARRAY AREA: 357.33 SQFTARRAY COVERAGE: 17.42%SYSTEM DISTRIBUTED WEIGHT: 2.32 LBSUNIRAC: FLASHKIT PRO POINT-LOAD: 23.66 LBSGREG ALBRIGHT PV MODULEUNIRAC SM LIGHT RAILUNIRAC L-FOOTATTACHMENTSUNIRAC FLASHKIT PROPV MODULEUNIRAC SM LIGHT RAILSOLAR MOUNT RACKING SYSTEM(E) SINGLE LAYER OFCOMP SHINGLE(E)2X4 TRUSS @ 24" O.C.5/16"x3.5" SS LAG BOLTWITH MIN 212" THREADEMBEDMENT, SEALEDPENETRATIONUNIRAC CHANNEL NUTGROUNDING END/MIDCLAMPUNIRAC L-FOOTATTACHMENTSUNIRAC FLASHKIT PRO2X4 TRUSS @ 24" O.C.3" MIN.6" MAX.TABLE 1 - ARRAY INSTALLATIONROOFPITCHROOFING TYPEATTACHMENT TYPEFRAMING TYPEMAX UNBRACEDLENGTH(FT.)STRUCTURALANALYSIS RESULTPENETRATIONPATTERNMAXATTACHMENTSPACING (IN.)MAX RAILOVERHANG(IN.)ROOF 120Comp ShingleUnirac Flashkit Pro2x4 @ 24" O.C.6PASSSTAGGERED72241. CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION. IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS, NOTIFY ENGINEER OF RECORD IMMEDIATELY.2. WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST, CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS.3. MAX RAIL OVERHANG APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS.ATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPV-3FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------MOUNTING DETAILSSTAGGERED DETAILFor Illustration purposes onlySTACKED DETAILFor Illustration purposes onlyGREG ALBRIGHT SOLAREDGE S440POWER OPTIMIZERSJUNCTIONBOX2 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#10 AWG MUST BE IN EMT CONDUIT STRING-19 FREEDOM FOREVER: FF-MP-BBB-4002 - #10 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUITTO OTHERLOADSUM(E) 200A / 2P MAINBREAKER(TOP FED)(N) 50A / 2PSUBPANELBREAKER(E) 200A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZTO UTILITYUNDERGROUNDFEED(N) 125A MINIMUM RATEDSUB PANEL1PH, 120/240V 60HZ(N) 30A / 2PPV BREAKER(E) UTILITY METER3 - #10 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) 30A RATEDAC DISCONNECTEATON DG221URB (OREQUIVALENT) KNIFEBLADE, LOCKABLE,NEMA 3R, UL LISTED3 - #10 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) SOLAREDGESE5000H-USRGM [SI1]INVERTERACDCRAPIDSHUTDOWNSWITCH3 - #8 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUITRELOCATE EXISTING15A/2P BREAKER FROM MSPNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED BREAKER SIZINGMAX. CONTINUOUS OUTPUT 21.00A @ 240V21.00X1.25=26.25AMPS30A BREAKER - OKSEE 705.12 OF 2020 NEC200X1.20=240240-200=40A ALLOWABLE BACKFEEDPV SYSTEM6.800 kW-DC5.000 kW-ACPV-4FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------THREE LINE DIAGRAMGREG ALBRIGHTRELOCATE THE 2P15A BREAKER INTO A NEW SUB PANEL FROM MSP PV-5FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------CONDUCTOR CALCULATIONSGREG ALBRIGHTWIRE SCHEDULERACEWAY#EQUIPMENTCONDUCTORQTY.AWGWIRESIZESTARTINGALLOWABLEAMPACITY @ 90°C310.15(B)(16)STARTINGCURRENTAPPLIED TOCONDUCTORSIN RACEWAYTEMPERATURECORRECTIONFACTOR310.15(B)(2)(a)ADJUSTMENTFACTOR FORMORE THAN 3CONDUCTORS310.15(B)(3)(a)ADJUSTEDCONDUCTORAMPACITY@ 90°CMAXIMUMCURRENTAPPLIED TOCONDUCTORSIN RACEWAY1DCMODULETOOPTIMIZER2104017.241140.0021.552DCOPTIMIZERTOJUNCTION BOX2104015.001140.0018.753DCJUNCTION BOXTOINVERTER4104015.0010.832.0018.754ACINVERTERTOAC DISCONNECT3104021.001140.0026.255ACAC DISCONNECTTOPOI3104021.001140.0026.256ACSUBPANELTOMSP385550.001155.0050.00----------------------------------------------------------------------------CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. PV-5AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------ELECTRICAL CALCULATIONSGREG ALBRIGHT MATERIAL LIST:PV-6FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------QTY.PARTPART #DESCRIPTION17MODULESPV-110-400FREEDOM FOREVER: FF-MP-BBB-40017OPTIMIZERSOPT-130-440-2SOLAREDGE S440 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON2JUNCTION BOXRAC-261-527600VDC NEMA 3R UL LISTED JUNCTION BOX2MOUNTING BRACKETRAC-211-201UNIRAC E-BOSS J-BOX MOUNTING BRACKET4ELECTRICAL ACCESSORIESEA-350-326STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE)4EQUIPMENT ACCESSORIESEA-350-327STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE)1INVERTERSINV-120-508SE5000H-US [SI1] RGM 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN1MONITORING EQUIPMENTME-180-502SOLAREDGE CELL MODEM1DISCONNECTSEE-321-03030A RATED 240VAC NEMA 3R UL LISTED35FITTINGS/ANCHORSRAC-241-250UNIRAC: FLASHKIT PRO13RAILSRAC-211-100UNIRAC SM LIGHT RAIL 168 INCH (TOTAL 181 FEET NEEDED)35FITTINGS/ANCHORSRAC-261-517BND T-BOLT AND NUT SS18ENDS/MIDSRAC-221-101SM MIDCLAMP PRO DRK18ENDS/MIDSRAC-221-209SM ENDCLAMP PRO W/ END CLAMP6FITTINGS/ANCHORSRAC-261-600BND SPLICE BAR PRO SERIES MILL18FITTINGS/ANCHORSRAC-261-510MICRO MNT BND TBOLT SS5RAILSRAC-211-209-NSE-BOSS CONDUIT MOUNT COMP KIT10RAILSRAC-211-200E-BOSS RAIL TRAY4RAILSRAC-211-206E-BOSS BRIDGE TRAY6RAILSRAC-211-207E-BOSS BRIDGE CLIPSOCPD SIZES:30A BREAKERSERVICE LIST:SUB PANEL INSERTEQUIPMENT & SERVICE LISTGREG ALBRIGHT NOTES:M690.13(B)MAIN PHOTOVOLTAICSYSTEM DISCONNECTTURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAYIFC 605.11.3.1(1) & 690.56(C)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC NEC 690.13(B)INVERTERDCSOLAR PV DC CIRCUITEVERY 10' ON CONDUIT AND ENCLOSURESSOLAR ELECTRICPV PANELS706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANEL!WARNINGSINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUITSNEC 710.15(C) & 692.9 (C)NEC 690.15 (B) & NEC 690.33(D)(2)DO NOT DISCONNECTUNDER LOADNEC 705.12(D) & NEC 690.59!CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDNEC 705.12(D) & NEC 690.59NEC 705.12(C) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.!WARNINGARC FLASH AND SHOCK HAZARDAPPROPRIATE PPE REQUIRED24 INCH3480 VAC42 INCH12 INCH1 INCHFLASH HAZARD BOUNDARYCAL/CM^2 FLASH HAZARD AT 18 INCHESSHOCK HAZARD WHEN COVER IS REMOVEDLIMITED APPROACHRESTRICTED APPROACH - 500 V CLASS 00 GLOVESPROHIBITED APPROACH - 500 V CLASS 00 GLOVESLOCATION:10018 CASCADIAN AVE SE,YELM, WA 98597PHOTOVOLTAICAC DISCONNECTPHOTOVOLTAIC AC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:21.00A240V!WARNINGTHIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEED AMPACITY OF BUSBARNEC 690.54NEC 705.12(B)(3)(3)NEC 706.15(C) AND NEC 110.16!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTNEC 690.31(E)PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURESNEC 690.31NEC 690.31(D)(2) NEC 690.13(B)PHOTOVOLTAICDC DISCONNECT706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHT NEC 690.53MAXIMUM DC VOLTAGEOF PV SYSTEMARRAYJ/BNEC 690.31(G)(3) & (4)706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)MAXIMUM VOLTAGEMAXIMUM CIRCUIT CURRENTMAX DC-DC CONVERTEROUTPUT CURRENTVAA13.548015PV-7FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------LABELSGREG ALBRIGHT1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C.ARIAL FONT.3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTWITH POP-RIVETS OR SCREWS 17 PV MODULESSUBPANELCAUTION:PV-7AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARDGREG ALBRIGHTWARNINGTURN OFF PHOTOVOLTAIC AC DISCONNECTPRIOR TO WORKING INSIDE PANELNCASCADIAN AVE SE POWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWNUTILITY METERMAIN SERVICE PANELAC DISCONNECTINVERTEREQUIPPED WITH RAPIDSHUTDOWNJUNCTION BOX JBM S P A C I N V UM S U B PV-8FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------SOLAREDGE OPTIMIZER CHARTOPTIMIZER CHARTGREG ALBRIGHT11-2021-4041-60234567891011121314151617181920 JBM S P A C I N V UM S U B PV-9FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------SAFETY PLANGREG ALBRIGHTSAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THEPRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ONTHE JHA SHEETINCIDENT REPORTING:INJURIES - CALL INJURY HOTLINE(855) 400-7233*If injury is life threatening, call 911 first THEN the Injury HotlineNON-INJURIES - USE MOBILE INCIDENT REPORTING(Auto, Property Damage, Near Miss)NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC:NAME: _______________________________________________ADDRESS: ___________________________________________NEAREST HOSPITAL:NAME:_______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATION:NAME: _______________________________________________PHONE NUMBER: _____________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN ANDSIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THEPLAN FOR WORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OBREAK AND WATER LOGTHIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS ISCOMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREESNAME0800HRS0900HRS1000HRS1100HRS1200HRS1300HRS1400HRS1500HRS1600HRSPOLICIESINSTRUCTIONS:1.SCAN QR LINK BELOW TOACCESS ALL FREEDOMFOREVER SAFETYPOLICIES AND PROGRAMS. JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protected fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees f):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:399465DESIGNED BY:S.G.CLIENT:TYLER OGDEN10018 CASCADIAN AVE SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573441APN: 6573-00-02800PHONE: (308) 520-4639EMAIL: RUNNERDUDE1217@GMAIL.COMSYSTEM:SYSTEM SIZE (DC): 17 X 400 = 6.800 kWSYSTEM SIZE (AC): 5.000 kW @ 240VMODULES: 17 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 17 X SOLAREDGE S440INVERTER: SOLAREDGE SE5000H-USRGM[SI1]DATE:1/16/2024---------SAFETY PLANGREG ALBRIGHT SCAN QR CODE TO ACCESS REFERENCE LINKPV INSTALLATION REFERENCESFREEDOM REFERENCESBATTERY INSTALLATION REFERENCESENPHASESOLAREDGE TESLAINSTALL HOTLINETESLA Storage SystemsNON‐BACKUP Battery SystemsSOLAREDGE Storage SystemsEnphase Storage SystemsMisc. Quick GuideFOR INSTALLATION REFERENCE ONLYV1.4 Performance Figures in %MECHANICAL LOADINGMODULE SPECIFICATIONS1722±21722.0 MM1316.0 MM227.2 MMTEMPERATURE RATINGSPACKAGING INFORMATIONMECHANICAL CHARACTERISTICSOPERATIONS CHARACTERISTICS35[1.38]UL 61730 | UL 61215 | ISO 9001 | ISO 14001ELECTRICAL CHARACTERISTICS forL. Matthew Snyder, Certification Manager Power Optimizer For North America 5440, 5500 25 YEAR WARRANTY PV power optimization at the module level / Specifically designed to work with SolarEdge residential inverters / Detects abnormal PV connector behavior, preventing potential safety issues* / Module -level voltage shutdown for installer and firefighter safety / Superior efficiency (99.5%) / Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading * Expected availability in 2022 O MID N M / Faster installations with simplified cable management and easy assembly using a single bolt / Flexible system design for maximum space utilization / Compatible with bifacial PV modules / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) solaredge.com solar.. c. / Power Optimizer For North America 5440, 5500 INPUT Rated Input DC Powers) 440 500 W Absolute Maximum Input Voltage (Voc) 60 Vdc MPPT Operating Range 8-60 Vdc Maximum Short Circuit Current (Ise) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1+/-0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014, 2017 & 2020 EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant ROHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 153 x 30 / 5.07 x 6.02 x 1.18 mm/in Weight (including cables) 655/1.5 gr / Ib Input Connector MC4al Wire Length 0.1/0.32 m / ft -Input Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 / (+) 7.S4, (-) 0.32 m / ft Operating Temperature Range") -40 to +85 C Protection Rating IP68 / Type66 Relative Humidity 0-100 % (1) Rated power ofthe module at STC will not exceed the power optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed (2) For other connector types please contact SolarEdge (3) For ambient temperature above +70°C / +158°F power de -rating is applied. Refer to Power Optimizers Temperature De -Rating Technical Note for more details S440,S500 1 8 1 14 1 18 Maximum String Length (Power Optimizers) l 25 50A Maximum Nominal Power per String 5700 (6000 with SE7600-US-SE11400-U) 6000 12750 W Maximum Nnowea t.onnecieo rower per xrmg One String 7200W (Permitted only when the difference in connected power between Refer to Footnote 5 15,000W strings is 1,000W or less) Two strings or more 780OW Parallel Strings of Different Lengths or Orientations Y (4) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safetyvoltage will be above the 30V requirement (5) If the inverters rated AC power s maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to: https.//www.solaredge.com/ sites/default/£ les/se-power-optimizer-single-string-design-application-note. pdf (6) It is not allowed to mix S -series and P -series Power Optimizers in new installations �. _ az - _ 135 , FY'ir © SolarEdge Technologies, Inc. All rights reserved. SODIREDGE, the SolarEdge logo, OPTIMIZED BY SODIREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February8, 2022 DS -000018 -NA. Subject to change without notice. AM. RoHS Intertek solaredge.com SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using SolarEdge SetApp Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014-2023 per articles 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Small, lightweight, and easy to install both outdoors or indoors Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) 12-25 YEAR WARRANTY SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Applicable to inverters with part number SEXXXXH-XXXXXBXX4 SE11400H- XXXXXBXX5 SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US Units OUTPUT Rated AC Power Output 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA ACOutput Voltage Min.-Nom.-Max. (211 - 240 - 264) Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) ---Vac ACFrequency (Nominal)59.3 - 60 - 60.5 (1)Hz Maximum Continuous Output Current @240V 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V 16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V 5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 Vdc Maximum Input Current @240V(2)10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1)For other regional settings please contact SolarEdge support. (2)A higher current source may be used; the inverter will limit its input current to the values stated. © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: June 19, 2023 DS-000153-NAM. Subject to change without notice. SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Applicable to inverters with part number SEXXXXH-XXXXXBXX4 SE11400H- XXXXXBXX5 SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), wireless SolarEdge Home Network (optional)(3), Wi-Fi (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(4) Consumption Metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown -NEC 2014-2023 per articles 690.11 and 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1741 SB, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547-2018, Rule 21, Rule 14 (HI), CSA C22.3 No. 9 Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14 6 AWG 1'' Maximum / 14 4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1 2 strings / 14 6 AWG 1'' Maximum / 1 3 strings / 14 6 AWG Dimensions with Safety Switch (H x W x D)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.06 x 14.6 x 7.3 / 535 x 370 x 185 21.06 x 14.6 x 8.2 / 535 x 370 x 208(5) in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 44.9 / 20.4(5)lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(6) Protection Rating NEMA 4X (Inverter with Safety Switch) (3)For more information, refer to the SolarEdge Home Network datasheet (4)Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BEI4. For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box. (5) SE11400H-USxxxBxx5 is the updated PN, though SE11400H-USxxxBxx4 will still be available. All specifications are similar for both models, EXCLUDING the weight and dimensions [HxWxD]; The weight and dimensions of SE11400H-USxxxBxx4 are 17.6 [kg] and 21.06-14.6-7.3 / 535-370-185 [in/mm], accordingly. (6)-rating information refer to the Temperature De-rating Technical Note for North America. How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills. Product specificationsEaton DG221URBCatalog Number: DG221URBEaton General duty non-fusible safety switch, single-throw, 30 A, 240 V,NEMA 3R, Rainproof, Painted galvanized steel, Two-pole, Two-wireGeneral specificationsEaton general duty non-fusible safetyswitchDG221URB7821131202326.88 in 10.81 in6.38 in 6 lbEaton Selling Policy 25-000, one (1) yearfrom the date of installation of theProduct or eighteen (18) months from thedate of shipment of the Product,whichever occurs first.UL ListedWARNING! Switch is not approved forservice entrance unless a neutral kit isinstalled.Product Name Catalog NumberUPCProduct Length/Depth Product HeightProduct Width Product WeightWarranty CertificationsCatalog NotesEaton Corporation plcEaton House30 Pembroke RoadDublin 4, IrelandEaton.com© 2023 Eaton. All RightsReserved.Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners.Eaton.com/socialmediaProduct specificationsGeneral duty safety switchPainted galvanized steelNon-fusible, single-throwNon-fusible2NEMA 3R240V30ATwo-poleResourcesEaton's Volume 2—Commercial DistributionDouble Up on SafetySwitching Devices Flex CenterEaton Specification Sheet - DG221URBProduct CategoryEnclosure materialTypeFuse configurationNumber of wiresEnclosureVoltage ratingAmperage RatingNumber Of PolesCatalogsMultimediaSpecifications and datasheets THE COMPLETE ROOF ATTACHMENT SOLUTIONFEATURING TECHNOLOGYFLASHKIT PRO is the complete attachment solution for composition shingle roofs. Featuring Unirac’s patented SHED & SEAL technology, a weather proof system which provides the ultimate protection against roof leaks. .LWWHGLQSDFNVIRUPD[LPXPFRQYHQLHQFHƜDVKLQJVDQGKDUGZDUHDUHDYDLODEOHLQ0LOORU'DUNƛQLVKHV With FLASHKIT pro, you have everything you need for a quick, professional installation.YOUR COMPLETE SOLUTIONFlashings, lags, continuous slot L-Feet and hardwareCONVENIENT 10 PACKS Packaged for speed and ease of handlingFLASHKIT PRO25 YEAR FULL-SYSTEM WARRANTYTRUSTED WATER SEAL FLASHINGS)25 48(67,216 25 &86720(5 6(59,&( 9,6,7 81,5$&&20 25 &$// FASTER INSTALLATION. 25-YEAR WARRANTY.FLASH.,7352,67+(&203/(7()/$6+,1*$1'$77$&+0(1762/87,21)25&20326,7,21522)6)25 48(67,216 25 &86720(5 6(59,&( 9,6,7 81,5$&&20 25 &$// PRE-INSTALL• Locate roof rafters and snap chalk lines to mark the installation point for each roof attachment.• 'ULOODƌSLORWKROHDWHDFKURRIDWWDFKPHQW)LOOHDFKSLORWKROHwith sealant.STEP 1 ,167$// FLASH.,7352)/$6+,1*• $GGD8VKDSHGEHDGRIURRIVHDODQWWRWKHXQGHUVLGHRIWKHƜDVKLQJwith the open side of the U pointing down the roof slope. Slide WKHDOXPLQXPƜDVKLQJXQGHUQHDWKWKHURZRIVKLQJOHVGLUHFWO\XSVORSHIURPWKHSLORWKROHDVVKRZQ$OLJQWKHLQGLFDWRUPDUNVRQWKHORZHUHQGRIWKHƜDVKLQJZLWKWKHFKDONOLQHVRQWKHURRIWRFHQWHUWKHUDLVHGKROHLQWKHƜDVKLQJRYHUWKHSLORWKROHLQWKHURRI:KHQLQVWDOOHGFRUUHFWO\WKHƜDVKLQJZLOOH[WHQGXQGHUWKHWZRFRXUVHVRIVKLQJOHVDERYHWKHSLORWKROHSTEP 2 ,167$///)227• )DVWHQ/IRRWDQG)ODVKLQJLQWRSODFHE\SDVVLQJWKHLQFOXGHGODJEROWDQGSUHLQVWDOOHGVWDLQOHVVVWHHOEDFNHG(3'0ZDVKHUWKURXJKWKH/IRRW(3'0JURPPHWDQGWKHUDLVHGKROHLQWKHƜDVKLQJLQWRthe pilot hole in the roof rafter.• 'ULYHWKHODJEROWGRZQXQWLOWKH/IRRWLVKHOGƛUPO\LQSODFH,WLVQRUPDOIRUWKH(3'0RQWKHXQGHUVLGHRIWKHVWDLQOHVVVWHHOEDFNHG(3'0ZDVKHUWRFRPSUHVVDQGH[SDQGEH\RQGWKHRXWVLGHHGJHRIthe steel washer when the proper torque is applied.TIP: • 8VHFDXWLRQWRDYRLGRYHUWRUTXHLQJWKHODJEROWLIXVLQJDQLPSDFWGULYHU• 5HSHDW6WHSVDQGDWHDFKURRIDWWDFKPHQWSRLQWSTEP 3 $77$&+/)227725$,/• ,QVHUWWKHLQFOXGHG7EROWVLQWRWKHORZHUVORWRQWKH5DLOVROGVHSDUDWHO\VSDFLQJWKHEROWVWRPDWFKWKHVSDFLQJEHWZHHQthe roof attachments.• Position the Rail against the L-Foot and insert the threaded end of WKH7%ROWWKURXJKWKHFRQWLQXRXVVORWLQWKH/)RRW$SSO\DQWLVHL]HWREROWWKUHDGVWRSUHYHQWJDOOLQJRIWKH7EROWDQGLQFOXGHGƌVHUUDWHGƜDQJHQXW3ODFHWKHƌƜDQJHQXWRQWKH7EROWDQGƛQJHUWLJKWHQ5HSHDW67(3XQWLODOO/)HHWDUHVHFXUHGWRWKH5DLOZLWKD7EROW$GMXVWWKHOHYHODQGKHLJKWRIWKH5DLODQGWRUTXHHDFKEROWWRIWOEV,167$//FLASH.,7352)/$6+,1*STEP 1 STEP 2 STEP 3 ,167$///)227 $77$&+/)227725$,/FLASHKIT PRO INSTALLATION GUIDE SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block!NOW FEATURING FLASHKIT PROThe Complete Roof Attachment SolutionNOW WITH UNIVERSAL MIDCLAMPSAccommodates 30mm-51mm module frames One tool, one-person installs are here!REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End CapsTHE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNTOPTIONAL FRONT TRIMNew & Improved: THE PROFESSIONALS’ CHOICEWith Superior AestheticsCONCEALED UNIVERSAL CLAMPSW WITH UNIVERSAL MIDCLAMPIWITHTHUUNINEVESRSRSALALALMMIDICLCLAMP25 YEAR FULL-SYSTEM WARRANTYFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORTENGINEERINGEXCELLENCEUNMATCHEDEXPERIENCEPERMITDOCUMENTATIONDESIGNTOOLSCERTIFIEDQUALITYBANKABLEWARRANTYBETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOLStart the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money.BETTER SYSTEMSONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics.BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOBTrust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAMProfessional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information.UNIVERSAL SELF STANDING MIDCLAMPSU-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEYVisit design.unirac.comBANKABLE WARRANTYDon’t leave your project to chance, Unirac has the ƛQDQFLDOVWUHQJWKWREDFNRXUSURGXFWVDQGUHGXFH\RXUULVNHave peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year OLPLWHGSURGXFWZDUUDQW\DQGD\HDUOLPLWHGƛQLVKZDUUDQW\TECHNICAL SUPPORTUnirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly VLPSOLƛHV\RXUSHUPLWWLQJDQGSURMHFWSODQQLQJSURFHVVCERTIFIED QUALITY PROVIDERUnirac is the only PV mounting vendor with ISO FHUWLƛFDWLRQVIRUDQG2+6$618001:2007, which means we deliver the highest standards IRUƛWIRUPDQGIXQFWLRQ7KHVHFHUWLƛFDWLRQVGHPRQVWUDWHRXUH[FHOOHQFHDQGFRPPLWPHQWWRƛUVWFODVVEXVLQHVVSUDFWLFHVUL2703BONDING & GROUNDINGMECHANICAL LOADINGSYSTEM FIRE CLASSIFICATIONLISTEDSOLARMOUNTCONCEALED UNIVERSAL ENDCLAMPSEND CAPS INCLUDED WITH EVERY ENDCLAMPENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAINFOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702PUB2018AUG31 – PRINTED UPDATE DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 1 Certificate of Compliance Certificate: 70131735 Master Contract: 266909 Project: 80082031 Date Issued: 2021-06-02 Issued To: Unirac 1411 Broadway NE Albuquerque, New Mexico, 87102 United States Attention: Klaus Nicolaedis The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Michael Hoffnagle Michael Hoffnagle PRODUCTS CLASS - C531302 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems CLASS - C531382 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems -Certified to US Standards Models: SM - SOLARMOUNT Flush-to-Roof is an extruded aluminum rail PV racking system that is installed parallel to the roof in landscape or portrait orientations. ULA - Unirac Large Array is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. Solarmount Certificate: 70131735 Project: 80082031 Master Contract: 266909 Date Issued: 2021-06-02 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 2 The system listed is designed to provide bonding/grounding, and mechanical stability for photovoltaic modules. The system is secured to the roof with the L-Foot components through the roofing material to building structure. Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end clamps. The modules are bonded to the racking system with the stainless-steel bonding mid clamps with piercing points. The system is grounded with 10 AWG copper wire to bonding/grounding lugs. Fire ratings of Class A with Type 1, 2, 3, 10, 19, 22 or 25 for steep slope. Tested at 5” interstitial gap which allows installation at any stand-off height. The grounding of the system is intended to comply with the latest edition of the National Electrical Code, to include NEC 250 & 690. Local codes compliance is required, in addition to national codes. All grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used during the certification testing for the current edition of the project report. The system may employ optimizers/micro-inverters and used for grounding when installed per installation instructions. UL 2703 Mechanical Load ratings: Downward Design Load (lb/ft²) 113.5 Upward Design Load (lb/ft²) 50.7 Down-Slope Load (lb/ft²) 16.13 Test Loads: Downward Load (lb/ft²) 170.20 Upward Load (lb/ft²) 76.07 Down-Slope Load (lb/ft²) 24.2 Unirac Large Array ULA is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. ULA aluminum components merge with SM rails and installer-supplied steel pipe. The SM rail system is secured to the horizontal Pipe using the Rail Bracket components. The Rear and Front cap secures the horizontal Pipe to the vertical Pipe. The Front cap is also used to secure the Cross brace. A Slider is attached to the vertical Pipe to secure the Cross brace. The SM rails, caps, slider, rail brackets, and cross braces materials are 6105-T5 aluminum extrusion. Fasteners materials are 304 stainless steel. Horizontal and vertical pipe materials meet the minimum requirements of ASTM A53 for galvanized steel pipe in 2” and 3” diameter. The mechanical load ratings from the SM test data will be applied to the ULA model. Fire Testing is not applicable due to being a ground mount system. APPENDIX HTechnicalData SheetsUnitsinplfin²SECTION MODULUS (X-AXIS)in³SECTION MODULUS (Y-AXIS)in³MOMENT OF INERTIA (X-AXIS) in4MOMENT OF INERTIA (Y-AXIS)in4RADIUS OF GYRATION (X-AXIS)inRADIUS OF GYRATION (Y-AXIS)in0.564 0.865 1.170.15 0.363 0.8980.067 0.113 0.2211.271CROSS SECTION AREA0.409 0.625 1.059BEAM HEIGHT1.70 2.57 3.00APPROX WEIGHT0.491 0.7280.254 0.269 0.5020.13 0.467 1.450.026 0.045 0.267PropertiesSOLARMOUNT LightSOLARMOUNT Rail Profile 2SOLARMOUNT HDPAGE H3TÜV Rheinland PTL, LLC, 1107 W. Fairmont Drive, Building A, Tempe, Arizona 85282, Tel (480) 966-1700, Fax (775) 314-6458 E417M7! Engineering Alliance, Inc 11 -December -2023 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87101 Tel: 505 242 6411 Attn.: Engineering Department https.11www. eng-alliance. com Subject: Engineering Certification for the Unirac SOLARMOUNT Flush Rail System to Support Photovoltaic Panels. The Unirac SOLARMOUNT Flush -to -Roof is an extruded aluminum rail system that is engineered to hold most framed solar modules to a roof structure and installed parallel to the roof. We have reviewed the SOLARMOUNT system, a proprietary mounting system constructed from modular parts which are intended for rooftop installation of solar photovoltaic (PV) panels; and have reviewed the U -Builder 2.0 Online tool. This U - Builder 2.0 software includes analysis for the SOLARMOUNT rails (SM LIGHT rail, SM STANDARD rail, and SM HEAVY DUTY rail) with Standard, Universal AF, and Pro Series hardware. All information, data, and analysis are in compliance with the following codes, city ordinances, and typical specifications: Codes: 1. 2015-2021 Washington State Building Code 2. ASCE/SEI 7-10 & 7-16 Minimum Design Loads for Buildings and Other Structures. 3. International Building Code, 2015 - 2021 Edition w/ Provisions from SEAOC PV -2 2017. 4. International Residential Code, 2015 - 2021 Edition w/ Provisions from SEAOC PV -2 2017. 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC -ES. 6. Aluminum Design Manual, 2015 & 2020 Edition. Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment: Shingle Roof: L -Foot, Flashkit Pro, Flashloc Comp, Flashloc Duo, Flashkit Pro SB Metal Roof: Standing Seam attachments, PM -9000S, PM Adjust Slotted Tile Roofs: Solar Hooks, Tile Replacement Attachment Spacing: Per U -Builder 2.0 Engineering report. Cantilever: The maximum cantilever length is L/3, where "L" is the span noted in the U -Builder 2.0 online tool. Clearance: 2" to 10" clear from top of roof to top of PV panel Tolerance(s): 1.0" tolerance for any specified dimension in this report is allowed for installation 4603 April Meadow Way, Sugar Land, TX 77479. Ph: 832 865 4757, Email: sahmad@eng-alliance.com W=7 Engineering Alliance, Inc Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. https.11www. eng-alliance. com Landscape - PV Panel long dimension is parallel to ridge/eave line of the roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of the roof and the PV panel is mounted on the short side. Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE/SEI 7-10 & 7-16 Component and Cladding design. Notes: 1. U -Builder 2.0 Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems and do not include roof capacity check. 2. Risk Category II per ASCE 7-16. 3. Topographic factor, kzt is 1.0. 4. Array Edge Factor YE = 1.5 5. Average parapet height is 0.0 ft. 6. Wind speeds are LRFD values. 7. Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U -Builder 2.0 design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U -Builder 2.0 software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U -Builder 2.0 Software is applicable to the project, and • Understand and determine the appropriate values for all input parameters of the U -Builder 2.0 software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U -Builder 2.0 engineering report and the manufacturer specifications are in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. Please feel free to call or email for any questions or clarifications. p� w. �y,.•' �Of •W �!u %; Prepared By: F - 01 Engineering Alliance, Inc Sugar Land, TX 0, 51947'0/ ................ �E�� 11 -DEC -2023 EXP.:15-DEC-2025 4603 April Meadow Way, Sugar Land, TX 77479. Ph: 832 865 4757, Email: sahmad@eng-alliance.com