Crump, Robert - PV Plans
THIS PROJECT COMPLIES WITH THE FOLLOWING:2018 INTERNATIONAL BUILDING CODE (IBC)2018 INTERNATIONAL RESIDENTIAL CODE (IRC)2018 INTERNATIONAL MECHANICAL CODE (IMC)2018 INTERNATIONAL PLUMBING CODE (IPC)2018 INTERNATIONAL FUEL GAS CODE (IFGC)2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC)2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC)2020 NATIONAL ELECTRICAL CODE (NEC)AS ADOPTED BY CITY OF YELMCODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:ROOF MOUNT PHOTOVOLTAIC SYSTEMPV-1SITE LOCATIONPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BARRAY AND STRUCTURAL TABLESPV-3MOUNTING DETAILSPV-4SLDPV-5CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7LABELSPV-7ASITE PLACARDPV-8OPTIMIZER CHARTPV-9SAFETY PLANPV-10SAFETY PLANAPPENDIXMANUFACTURER SPECIFICATION SHEETSCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACEPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROMDC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2020 NECTHE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERUTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEMSOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDSINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITATTACHED TO THE ROOF USING CONDUIT MOUNT.PV-1FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------GREG ALBRIGHTSITE LOCATION MSPUMACINVJBSITE PLANSCALE: 2/25" = 1'-0"1PV-2FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------ROOF AREA: 2274.91 SQ FTSITE PLANLEGEND:CHIMNEYPIPE VENTMODULESCONDUITSETBACKAC DISCONNECTJUNCTION BOXINVERTERMAIN SERVICEPANEL0ACJBINVMSP0GREG ALBRIGHT91'-7"23'-10"5 2 ' - 0 "106'-8"37'-8"30'-8"24'-11"5' - 6 " 5'- 9 "DRIVEWAYGREENBRIER ST SE (E) MAIN SERVICE PANEL(E) UTILITY METER(N) SOLAREDGE SE3800H-USRGM [SI1]INVERTER WITH RAPID SHUTDOWN(N) VISIBLE LOCKABLE LABELED DISCONNECTEATON DG221NRB (OR EQUIVALENT)(N) 9 FREEDOM FOREVER: FF-MP-BBB-400(N) JUNCTION BOXROOF LINEPROPERTY LINEFENCE/GATEPV SYSTEM3.600 kW-DC3.800 kW-ACTOTAL ROOF AREA RIDGE SETBACK CALCS:TOTAL ROOF AREA: 2274.91 SQ FTSINGLE MODULE AREA: 21.01937947 SQ FTTOTAL NUMBER OF MODULES: 9TOTAL AREA OF MODULES: 189.17 SQ FTROOF COVERAGE: 8.32%FIRE SPRINKLERS : NOTHIS SYSTEM DESIGNED WITH:WIND SPEED: 97WIND EXPOSURE: BSNOW LOAD: 15 MSPUMACINVJBPV-2AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------ROOF PLANSCALE: 3/32" = 1'-0"1NOTES:1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3.JUNCTION BOX IS MOUNTED TO THE RAIL.ROOF AREA: 2274.91 SQ FTROOF PLAN WITH MODULES LAYOUTLEGEND:CHIMNEYPIPE VENTMODULESCONDUITSETBACKAC DISCONNECTJUNCTION BOXINVERTERMAIN SERVICEPANEL0ACJBINVMSP0TOTAL ROOF AREA: 2274.91 SQ FTTOTAL ARRAY AREA: 189.17 SQ FTARRAY COVERAGE: 8.32%SYSTEM DISTRIBUTED WEIGHT: 2.32 LBSROCKIT SMART SLIDE POINT-LOAD: 27.4LBSGREG ALBRIGHT(E) MAIN SERVICE PANEL(E) UTILITY METER(N) SOLAREDGE SE3800H-USRGM [SI1]INVERTER WITH RAPID SHUTDOWN(N) VISIBLE LOCKABLE LABELED DISCONNECTEATON DG221NRB (OR EQUIVALENT)(N) 9 FREEDOM FOREVER: FF-MP-BBB-400(N) JUNCTION BOXROOF LINEPV SYSTEM3.600 kW-DC3.800 kW-ACTHIS SYSTEM DESIGNED WITH:WIND SPEED: 97WIND EXPOSURE: BSNOW LOAD: 153' - 0 "3'-0"3'-0"3'-0"3'-0"3'-0"3'-0"3'- 0 "3'-0"FIRE ACCESSPATHWAYSFIRE ACCESSPATHWAYS PV-2BFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------ARRAY DETAILSROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCHARRAY PITCHAZIMUTHROOF AREAARRAY AREAROOF 1922222161066.4 SQ FT189.17 SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FTROOF DETAILS:TOTAL ROOF AREA: 2274.91 SQ FTTOTAL ARRAY AREA: 189.17 SQFTARRAY COVERAGE: 8.32%SYSTEM DISTRIBUTED WEIGHT: 2.32 LBSROCKIT SMART SLIDE POINT-LOAD: 27.4 LBSGREG ALBRIGHT ROCKIT MOUNTROOF SURFACESKIRTROCKIT MOUNTROOFMEMBRANEPV MODULEROCKIT MOUNTROOFMEMBRANE2" MIN. EMBED.2" MIN. EMBED.2 x #12 WOOD SCREWWITH 2" MIN. EMBEDMENTAND FLAT WASHER2 x #12 WOOD SCREWWITH 2" MIN. EMBEDMENTAND FLAT WASHER2 x #12 WOODSCREW WITH 2"MIN. EMBEDMENTAND FLAT WASHER2" MIN. EMBED.ROCKIT RAIL-LESSPV MODULE3" MIN.(E)2X4 TRUSS @ 24" O.C.TABLE 1 - ARRAY INSTALLATIONROOFPITCHROOFING TYPEATTACHMENT TYPEFRAMING TYPEMAX UNBRACEDLENGTH(FT.)STRUCTURALANALYSIS RESULTPENETRATIONPATTERNMAXATTACHMENTSPACING (IN.)MAX RAILOVERHANG(IN.)ROOF 122Comp ShingleEcofasten RockIt Smart Slide2x4 Truss @ 24" O.C.7.41PASSSTAGGERED72" OC24"1. CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION. IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS, NOTIFY ENGINEER OF RECORD IMMEDIATELY.2. WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST, CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS.3. MAX RAIL OVERHANG APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS.ATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPV-3FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------MOUNTING DETAILSSTAGGERED DETAILFor Illustration purposes onlySTACKED DETAILFor Illustration purposes onlyGREG ALBRIGHT SOLAREDGE S440POWER OPTIMIZERSJUNCTIONBOX2 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#10 AWG MUST BE IN EMT CONDUIT STRING-19 FREEDOM FOREVER: FF-MP-BBB-4002 - #10 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUIT(N) SOLAREDGESE3800H-USRGM [SI1]INVERTERACDCRAPIDSHUTDOWNSWITCHUM(E) 200A / 2PMAIN BREAKER(TOP FED)(E) 200A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZ(E) UTILITY METER(N) LINESIDE TAP VIA ULLISTED CONNECTORTO UTILITYUNDERGROUNDFEED3 - #10 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) 30A FUSEDAC DISCONNECTEATON DG221NRB (OREQUIVALENT)WITH 20A FUSES,KNIFEBLADE, LOCKABLE, NEMA3R, UL LISTED3 - #6 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMT CONDUITNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED BREAKER SIZINGMAX. CONTINUOUS OUTPUT 16.00A @ 240V16.00X1.25=20.00AMPS20A BREAKER - OKSEE 705.12 OF 2020 NEC200X1.20=240240-200=40A ALLOWABLE BACKFEEDPV-4FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------THREE LINE DIAGRAMGREG ALBRIGHT PV-5FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------CONDUCTOR CALCULATIONSGREG ALBRIGHTWIRE SCHEDULERACEWAY#EQUIPMENTCONDUCTORQTY.AWGWIRESIZESTARTINGALLOWABLEAMPACITY @ 90°C310.15(B)(16)STARTINGCURRENTAPPLIED TOCONDUCTORSIN RACEWAYTEMPERATURECORRECTIONFACTOR310.15(B)(2)(a)ADJUSTMENTFACTOR FORMORE THAN 3CONDUCTORS310.15(B)(3)(a)ADJUSTEDCONDUCTORAMPACITY@ 90°CMAXIMUMCURRENTAPPLIED TOCONDUCTORSIN RACEWAY1DCMODULETOOPTIMIZER2104017.241140.0021.552DCOPTIMIZERTOJUNCTION BOX2104015.001140.0018.753DCJUNCTION BOXTOINVERTER2104015.001140.0018.754ACINVERTERTOAC DISCONNECT3104016.001140.0020.005ACAC DISCONNECTTOPOI367516.001175.0020.00--------------------------------------------------------------------------------CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST:PV-6FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------QTY.PARTPART #DESCRIPTION9MODULESPV-110-400FREEDOM FOREVER: FF-MP-BBB-4009OPTIMIZERSOPT-130-440-2SOLAREDGE S440 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON1JUNCTION BOXRAC-260-049600VDC NEMA 3R UL LISTED JUNCTION BOX1MOUNTING BRACKETRAC-211-201UNIRAC E-BOSS J-BOX MOUNTING BRACKET2ELECTRICAL ACCESSORIESEA-350-326STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE)2EQUIPMENT ACCESSORIESEA-350-327STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE)1INVERTERSINV-120-388SE3800H-US [SI1] RGM 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN1MONITORING EQUIPMENTME-180-502SOLAREDGE CELL MODEM1DISCONNECTSEE-321-03630A RATED 240VAC NEMA 3R UL LISTED2FUSESBR-330-02020A FUSE 1 PH 240VAC3ELECTRICAL ACCESSORIESEA-350-113IDEAL B-TAP 4/0-10 AWG16FITTINGS/ANCHORSRAC-265-034ROCKIT SMART SLIDE17FOOTINGS RAC-265-004"MFG: ECO FASTEN, ROCKIT COMP COUPLING AL BLK, MFG SKU: 2011021"16FOOTINGS RAC-265-001"MFG: ECO FASTEN, GF-1 FLASHING GLV BLK 8X10"", MFG SKU: 3012020"FOOTINGS RAC-265-028"MFG: ECO FASTEN, SKIRT AL BLK 35MM & 40MM A80, MFG SKU: 2099012"FITTINGS/ANCHORSRAC-265-031"MFG: ECO FASTEN, SKIRT END CAP PLS 35MM&40MM-A, MFG SKU: 2099035"9RAILSRAC-265-018"MFG: ECO FASTEN, FRAME MLPE MOUNT SS, MFG SKU: 4011012"32SCREWRAC-265-035ROCKIT SCREW #12X3OCPD SIZES:20A BREAKERSERVICE LIST:NONEEQUIPMENT & SERVICE LISTGREG ALBRIGHT NOTES:M690.13(B)MAIN PHOTOVOLTAICSYSTEM DISCONNECTTURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAYIFC 605.11.3.1(1) & 690.56(C)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC NEC 690.13(B)INVERTERDCSOLAR PV DC CIRCUITEVERY 10' ON CONDUIT AND ENCLOSURESSOLAR ELECTRICPV PANELS706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANEL!WARNINGSINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUITSNEC 710.15(C) & 692.9 (C)NEC 690.15 (B) & NEC 690.33(D)(2)DO NOT DISCONNECTUNDER LOADNEC 705.12(D) & NEC 690.59!CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDNEC 705.12(D) & NEC 690.59NEC 705.12(C) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.!WARNINGARC FLASH AND SHOCK HAZARDAPPROPRIATE PPE REQUIRED24 INCH3480 VAC42 INCH12 INCH1 INCHFLASH HAZARD BOUNDARYCAL/CM^2 FLASH HAZARD AT 18 INCHESSHOCK HAZARD WHEN COVER IS REMOVEDLIMITED APPROACHRESTRICTED APPROACH - 500 V CLASS 00 GLOVESPROHIBITED APPROACH - 500 V CLASS 00 GLOVESLOCATION:16467 GREENBRIER ST SE,YELM, WA 98597PHOTOVOLTAICAC DISCONNECTPHOTOVOLTAIC AC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:16.00A240V!WARNINGTHIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEED AMPACITY OF BUSBARNEC 690.54NEC 705.12(B)(3)(3)NEC 706.15(C) AND NEC 110.16!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTNEC 690.31(E)PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURESNEC 690.31NEC 690.31(D)(2) NEC 690.13(B)PHOTOVOLTAICDC DISCONNECT706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHT NEC 690.53MAXIMUM DC VOLTAGEOF PV SYSTEMARRAYJ/BNEC 690.31(G)(3) & (4)706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)MAXIMUM VOLTAGEMAXIMUM CIRCUIT CURRENTMAX DC-DC CONVERTEROUTPUT CURRENTVAA10.548015PV-7FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------LABELSGREG ALBRIGHT1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C.ARIAL FONT.3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTWITH POP-RIVETS OR SCREWS CAUTION:PV-7AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARDGREG ALBRIGHTWARNINGTURN OFF PHOTOVOLTAIC AC DISCONNECTPRIOR TO WORKING INSIDE PANELNPOWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWN9 PV MODULESUTILITY METERMAIN SERVICE PANELAC DISCONNECTINVERTER EQUIPPEDWITH RAPID SHUTDOWNJUNCTION BOXGREENBRIER ST SE MSPUMACINVJBPV-8FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------SOLAREDGE OPTIMIZER CHARTOPTIMIZER CHARTGREG ALBRIGHT11-1011-2021-3031-4041-5051-602345678910 MSPUMACINVJBPV-9FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------SAFETY PLANGREG ALBRIGHTSAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THEPRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ONTHE JHA SHEETINCIDENT REPORTING:INJURIES - CALL INJURY HOTLINE(855) 400-7233*If injury is life threatening, call 911 first THEN the Injury HotlineNON-INJURIES - USE MOBILE INCIDENT REPORTING(Auto, Property Damage, Near Miss)NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC:NAME: _______________________________________________ADDRESS: ___________________________________________NEAREST HOSPITAL:NAME:_______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATION:NAME: _______________________________________________PHONE NUMBER: _____________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN ANDSIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THEPLAN FOR WORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OBREAK AND WATER LOGTHIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS ISCOMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREESNAME0800HRS0900HRS1000HRS1100HRS1200HRS1300HRS1400HRS1500HRS1600HRSPOLICIESINSTRUCTIONS:1.SCAN QR LINK BELOW TOACCESS ALL FREEDOMFOREVER SAFETYPOLICIES AND PROGRAMS. JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protected fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees f):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:ELECTRICAL ADMINISTRATOR ALBRIG*807C1FREEDOM FOREVER LLC43445 BUSINESS PARK DR #110, TEMECULA,CA 92590Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:401294DESIGNED BY:A.N.CLIENT:ROBERT CRUMP16467 GREENBRIER ST SE, YELM, WA 98597AHJ: CITY OF YELMUTILITY: PUGET SOUND ENERGYMETER: 163573470APN: 5651-00-04100PHONE: (253) 380-1632EMAIL: CRUMPGL@MSN.COMSYSTEM:SYSTEM SIZE (DC): 9 X 400 = 3.600 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 9 X FREEDOM FOREVER:FF-MP-BBB-400OPTIMIZERS: 9 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:1/23/2024---------SAFETY PLANGREG ALBRIGHT SCAN QR CODE TO ACCESS REFERENCE LINKPV INSTALLATION REFERENCESFREEDOM REFERENCESBATTERY INSTALLATION REFERENCESENPHASESOLAREDGE TESLAINSTALL HOTLINETESLA Storage SystemsNON‐BACKUP Battery SystemsSOLAREDGE Storage SystemsEnphase Storage SystemsMisc. Quick GuideFOR INSTALLATION REFERENCE ONLYV1.4 Performance Figures in %MECHANICAL LOADINGMODULE SPECIFICATIONS1722±21722.0 MM1316.0 MM227.2 MMTEMPERATURE RATINGSPACKAGING INFORMATIONMECHANICAL CHARACTERISTICSOPERATIONS CHARACTERISTICS35[1.38]UL 61730 | UL 61215 | ISO 9001 | ISO 14001ELECTRICAL CHARACTERISTICS forL. Matthew Snyder, Certification Manager Power Optimizer For North America 5440, 5500 25 YEAR WARRANTY PV power optimization at the module level / Specifically designed to work with SolarEdge residential inverters / Detects abnormal PV connector behavior, preventing potential safety issues* / Module -level voltage shutdown for installer and firefighter safety / Superior efficiency (99.5%) / Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading * Expected availability in 2022 O MID N M / Faster installations with simplified cable management and easy assembly using a single bolt / Flexible system design for maximum space utilization / Compatible with bifacial PV modules / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) solaredge.com solar.. c. / Power Optimizer For North America 5440, 5500 INPUT Rated Input DC Powers) 440 500 W Absolute Maximum Input Voltage (Voc) 60 Vdc MPPT Operating Range 8-60 Vdc Maximum Short Circuit Current (Ise) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1+/-0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014, 2017 & 2020 EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant ROHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 153 x 30 / 5.07 x 6.02 x 1.18 mm/in Weight (including cables) 655/1.5 gr / Ib Input Connector MC4al Wire Length 0.1/0.32 m / ft -Input Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 / (+) 7.S4, (-) 0.32 m / ft Operating Temperature Range") -40 to +85 C Protection Rating IP68 / Type66 Relative Humidity 0-100 % (1) Rated power ofthe module at STC will not exceed the power optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed (2) For other connector types please contact SolarEdge (3) For ambient temperature above +70°C / +158°F power de -rating is applied. Refer to Power Optimizers Temperature De -Rating Technical Note for more details S440,S500 1 8 1 14 1 18 Maximum String Length (Power Optimizers) l 25 50A Maximum Nominal Power per String 5700 (6000 with SE7600-US-SE11400-U) 6000 12750 W Maximum Nnowea t.onnecieo rower per xrmg One String 7200W (Permitted only when the difference in connected power between Refer to Footnote 5 15,000W strings is 1,000W or less) Two strings or more 780OW Parallel Strings of Different Lengths or Orientations Y (4) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safetyvoltage will be above the 30V requirement (5) If the inverters rated AC power s maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to: https.//www.solaredge.com/ sites/default/£ les/se-power-optimizer-single-string-design-application-note. pdf (6) It is not allowed to mix S -series and P -series Power Optimizers in new installations �. _ az - _ 135 , FY'ir © SolarEdge Technologies, Inc. All rights reserved. SODIREDGE, the SolarEdge logo, OPTIMIZED BY SODIREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February8, 2022 DS -000018 -NA. Subject to change without notice. AM. RoHS Intertek solaredge.com SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using SolarEdge SetApp Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014-2023 per articles 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Small, lightweight, and easy to install both outdoors or indoors Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) 12-25 YEAR WARRANTY SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Applicable to inverters with part number SEXXXXH-XXXXXBXX4 SE11400H- XXXXXBXX5 SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US Units OUTPUT Rated AC Power Output 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA ACOutput Voltage Min.-Nom.-Max. (211 - 240 - 264) Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) ---Vac ACFrequency (Nominal)59.3 - 60 - 60.5 (1)Hz Maximum Continuous Output Current @240V 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V 16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V 5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 Vdc Maximum Input Current @240V(2)10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1)For other regional settings please contact SolarEdge support. (2)A higher current source may be used; the inverter will limit its input current to the values stated. © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: June 19, 2023 DS-000153-NAM. Subject to change without notice. SolarEdge Home Wave Inverter For North America SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Applicable to inverters with part number SEXXXXH-XXXXXBXX4 SE11400H- XXXXXBXX5 SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), wireless SolarEdge Home Network (optional)(3), Wi-Fi (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(4) Consumption Metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown -NEC 2014-2023 per articles 690.11 and 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1741 SB, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547-2018, Rule 21, Rule 14 (HI), CSA C22.3 No. 9 Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14 6 AWG 1'' Maximum / 14 4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1 2 strings / 14 6 AWG 1'' Maximum / 1 3 strings / 14 6 AWG Dimensions with Safety Switch (H x W x D)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.06 x 14.6 x 7.3 / 535 x 370 x 185 21.06 x 14.6 x 8.2 / 535 x 370 x 208(5) in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 44.9 / 20.4(5)lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(6) Protection Rating NEMA 4X (Inverter with Safety Switch) (3)For more information, refer to the SolarEdge Home Network datasheet (4)Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BEI4. For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box. (5) SE11400H-USxxxBxx5 is the updated PN, though SE11400H-USxxxBxx4 will still be available. All specifications are similar for both models, EXCLUDING the weight and dimensions [HxWxD]; The weight and dimensions of SE11400H-USxxxBxx4 are 17.6 [kg] and 21.06-14.6-7.3 / 535-370-185 [in/mm], accordingly. (6)-rating information refer to the Temperature De-rating Technical Note for North America. How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills. Product specificationsEaton DG221NRBCatalog Number: DG221NRBEaton General duty cartridge fuse safety switch, 30 A, NEMA 3R, Redpainted galvanized steel, Class H fuses, Fusible with neutral, Two-pole,Three-wire, Category: general duty safety switch, 240 VGeneral specificationsEaton general duty cartridge fuse safetyswitchDG221NRB7821131203176.88 in 10.81 in6.38 in 6 lbEaton Selling Policy 25-000, one (1) yearfrom the date of installation of theProduct or eighteen (18) months from thedate of shipment of the Product,whichever occurs first.UL ListedMaximum hp ratings apply only whendual element fuses are used. 3-Phase hprating shown is a grounded B phaserating, UL listed.Product Name Catalog NumberUPCProduct Length/Depth Product HeightProduct Width Product WeightWarranty CertificationsCatalog NotesEaton Corporation plcEaton House30 Pembroke RoadDublin 4, IrelandEaton.com© 2023 Eaton. All RightsReserved.Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners.Eaton.com/socialmediaPhysical AttributesNEMA 3RPainted galvanized steelFusible with neutralTwo-pole3General duty, cartridge fusedPerformance Ratings30AClass H fuses240VMiscellaneousGeneral duty safety switchResourcesEaton's Volume 2—Commercial DistributionDouble Up on SafetySwitching Devices Flex CenterEaton Specification Sheet - DG221NRBEnclosureEnclosure materialFuse configurationNumber Of PolesNumber of wiresTypeAmperage RatingFuse class provisionVoltage ratingProduct CategoryCatalogsMultimediaSpecifications and datasheets INSULATION -PIERCING TAP CONNECTORS CONECTORES DE DERIVACION QUE PERFORAN EL AISLAMIENTO Installation Instructions: Improperly installed electrical wiring can be dangerous Aand cause electrical fires. The connector chosen must be sized to the wires being used. Consult local building code before doing any electrical work. For assistance, refer to an instructional book or consult a qualified electrician. Contact with electricity can cause serious injury or death. Use on insulated cable only. [RHH, RHW(-2), THHN, THHW, THW, THWN, USE, XHHW(-2). Consult factory for other insulation types]. If the installation is to be made on an energized run, the tap conductor must be under no load and must not be grounded. Use electrically insulated gloves. De -energize the run cable if there are any questions of these conditions being met. 1. Determine the direction for the tap conductor to exit and discard one end cap. See figure 1. 2. Position the main (or feeder) side of the connector around the run cable and tighten the bolt finger tight. See figure 2. If required, loosen the bolt slightly to allow the connector to open completely. DISASSEMBLY NOT RECOMMENDED. The plastic 'Turbo" spacer holds the connector open which eases installation and ensures proper connections. 3. Cut the end of the tap cable squarely. DO NOT STRIP CABLE INSULATION. 4. Insert the tap cable into the tap side of the connector until it is seated in the remaining end cap. See figure 3. 5. Continue tightening the torque regulating bolt with a standard box or socket wrench until the torque regulating piece breaks away. If the connector has two (2) assembly bolts, alternately tighten until the hexagonal torque devices break away. See figures 4a & 4b. Note that the plastic "turbo" spacer on the side will also break. To make the installation even easier and to relieve torque from the cables, a second wrench can be used on the hexagonal piece on the bottom of the connector. DO NOT use gripping type pliers, pipe, open ended or adjustable wrenches as these may damage the hexagonal torque regulating device. A torque wrench is not required. MAKE SURE ONLY THE TOP HEXAGONAL TORQUE DEVICE OF THE BOLT HEAD IS USED FOR ASSEMBLY. THE SECOND HEX PIECE [CLOSER TO THE BODY OF THE CONNECTOR] IS USED FOR DISASSEMBLY. Note: The torque regulating bolt ensures the correct torque is applied to the conductors without using a torque wrench. Important information such as run and tap ranges, voltage ratings and material/temperature ratings is marked on the connector. figure 1 @ 0 Before After correct Torque Torque Reached, Applied One Hex Piece Breaks -Away figure 4a figure 4b UListed L 4868 Pressure Cable Connectors File No. E-5238 Suitable for use on the line side of the service equipment. Instalacion Instrucciones: Los cables electricos mal instalados pueden ser peligrosos y provocar incendios. EI conector escogido Bebe ser de un tamano adecuado para los cables que se utilicen. Consulte los c6digos de construccion locales antes de efectuar trabajos electricos. Si necesita ayuda, consulte un libro de instrucciones o consulte con un electricista capacitado. Use solo en cable aislado. [RHH, RHW(-2), THHN, THHW, THW, THWN, USE, XHHW(-2). Consulte con la fabrica para obtener informacion sobre otros tipos de aislamiento]. Si se va a hacer la instalacion sobre un cable con corriente el conductor derivado Bebe estar libre de carga y no Bebe estar aterado. Use guantes con aislamiento electrico. Quite le la corriente al cable del cual se hace la derivacion si no se pueden cumplir estas condiciones. EI contacto con electricidad puede producir lesiones graves o mortales. 1. Determine la direccion en la que el conductor derivado saldra y deseche la tapa terminal sobrante. Vea la ilustracidn 1. 2. Coloque el lado principal (o de alimentacion) del conector alrededor del cual se hace la derivacion y apriete firmemente el dello del perno. Vea la ilustraci6n 2. Si hace falta, afloje el perno ligeramente para permitir que el conector se abra completamente. NO ES RECOMENDABLE DESARMAR EL CONECTOR. EI espaciador 'Turbo" de plastico mantiene al conector abierto, Io cual facilita la instalacion y asegura que las conexiones se hagan correctamente. 3. Corte el extremo del cable de derivacion perpendicularmente a su eje. NO PELE EL AISLAMIENTO DEL CABLE. 4. Inserte el cable de derivacion en el lado de derivacion del conector hasta que tope contra la tapa terminal que queda. Vea la ilustraci6n 3. 5. Continue apretando este perno que regula la torsion con una Ilave estandar o de cubo hasta que la pieza que regula la torsion se parta y se separe. Si el conector tiene dos (2) pernos de ensamblaje, apriotelos alternativamente hasta que el dispositivo de regulacion de torcib se parta. Vea la ilustraci6n 4a y 4b. Observe que el espaciador "turbo" de plastico en el costado tambien se fracturara. Para hacer esta instalacion a6n mos facil y para aliviar la torsion de los cables, se puede usar una. segunda Ilave sobre la pieza hexagonal al fondo del conector. NO USE alicates de presi6n, (laves de turbo, (laves comunes o ajustables ya que estas pueden danar el dispositivo hexagonal que regula la torsion. No se requiere una Ilave de torsion. ASEGORESE DUE SE USE, PARA EL ENSAMBLADO, SOLO EL DISPOSITIVO SUPERIOR DE REGULAC16N DE TORSION DE LA CABEZA DEL PERNO. LA SEGUNDA PIEZA HEXAGONAL (LA MAS CERCANA AL CUERPO DEL CONECTOR) SE USA SOLO PARA DESARMAR EL CONECTOR. Nota: EI perno regulador de torsion garantiza la aplicacion de la torsion correcta a los conductores sin usar una Ilave de torsion. La informacion importante de longitud de cable pelado y de toma, las clasificaciones de materiales y temperatura esta marcada en el conector. B -TAP° INSULATION PIERCING TAP CONNECTORS TORQUE AND CURRENT RATINGS (Solid and/or Stranded) +10-14 Cu SOLID/STRANDED; 10-12 Al SOLID/STRANDED ++2-10 Cu SOLID/STRANDED; 2-10 Al STRANDED +++2-10 Cu SOLID/STRANDED; 2-8 Al STRANDED ++++10-14 Cu SOLID/STRANDED; 10-12 Al STRANDED Full line is 600V dual -rated, 194°F(90°C) " Based on NEC Table 310-161996 (Not more than 3 insulated conductors in a raceway at ambient temperature of 30° C) for the largest tap wire size. WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov. AADVERTENCIA: Cancer y Dana Reproductivo - www.P65Warninas.ca.aov. One year limited warranty. See idealind.com for more information. Garantra limitada de un ano. Visite www.idealind.com para obtener detalles de la garantfa. 1800 S. Prairie Drive Sycamore, IL, U.S.A. 800-435-0705 • www.idealind.com ND 9053-2 1839420 NOMINAL TAP CURRENT RATIING CATALOG# MAIN TAP TORQUE (IN AMPS)* BTC2/0-14 2/0-4 10-14+ 801N. LBS. 40 BTC1/0-10 1/0-8 2-10- 801N. LBS. 130 BTC4/0-10 4/0-3 2-10- 1251N. LBS. 130 BTC4/0-6 4/0-2 1/0-6 1601N. LBS. 170 BTC4/0-2 4/0-2 4/0-2 1601N. LBS. 260 BTC250-6 250-4 4/0-6 1601N. LBS. 260 BTC250-4 250-1 3/0-4 1601N. LBS. 225 BTC250-2 250-1/0 4/0-2 1601N. LBS. 260 BTC350-1/0 350-1/0 350-1/0 3301N. LBS. 350 BTC500-4 500-2/0 4/0-4 3301N. LBS. 260 BTC500-1/0 500-4/0 350-1/0 3301N. LBS. 350 BTC500-14 750-3/0 10-14... 801N. LBS. 40 BTC750-250 750-250 500-250 3301N. LBS. 430 +10-14 Cu SOLID/STRANDED; 10-12 Al SOLID/STRANDED ++2-10 Cu SOLID/STRANDED; 2-10 Al STRANDED +++2-10 Cu SOLID/STRANDED; 2-8 Al STRANDED ++++10-14 Cu SOLID/STRANDED; 10-12 Al STRANDED Full line is 600V dual -rated, 194°F(90°C) " Based on NEC Table 310-161996 (Not more than 3 insulated conductors in a raceway at ambient temperature of 30° C) for the largest tap wire size. WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov. AADVERTENCIA: Cancer y Dana Reproductivo - www.P65Warninas.ca.aov. One year limited warranty. See idealind.com for more information. Garantra limitada de un ano. Visite www.idealind.com para obtener detalles de la garantfa. 1800 S. Prairie Drive Sycamore, IL, U.S.A. 800-435-0705 • www.idealind.com ND 9053-2 1839420 IDEAL INDUSTRIES, INC. 1375 Park Avenue s 6017.com ALL IDEAL Customers 2/9/23 Subject: The Buchanan B-TAP® splice/tap connectors meet the 2020 NEC article 230.46 requirement for line side applications The Buchanan B-TAP® brand of insulation piercing connectors which correspond to part numbers beginning with BTC meet the requirements of article 230.46 of the 2020 NEC. These products have already been tested to the newer requirements. The installation instructions are in the process of being updated to show the required notation: suitable for use on the line side of the service equipment. This change will take a few weeks to get into our production. In addition, the marking SR will be added to the product. That addition is in process and will take a few months to complete. This notice will provide confirmation to the inspectors that B-TAP® products meet the requirements of the 2020 and 2023 NEC article 230.46 Spliced and Tapped Conductors. Sushil Keswani Director of Engineering IDEAL Industries, Inc., UL Product W OUL Solutions ZMVV.E5238 - Wire Connectors and Soldering Lugs Note: We are enhancing our systems and you may notice duplicate entries/missing/outdated data. During this interim period, please contact our Customer Service at https://www.ul.com/about/locations. Wire Connectors and Soldering Lugs IDEAL INDUSTRIES INC E5238 1375 Park Ave SYCAMORE, IL 60178 United States View model for additional information Insulated butt splice crimp type connectors, Model(s): BVS1, BVS2, BVSS Insulated flange spade type crimp cconnectors, Model(s): SV5-3.7, SVL5-4, SVL5-6 Insulated flange spade type crimp connectors, Model(s): FSNYD1-3.7, FSNYD1-4, FSNYD1-5, FSNYD2-3.7, FSNYD2-4, FSNYD2-5, FSNYD5-3.7, FSNYD5-4, FSNYD5-5 Insulated hook type crimp connectors, Model(s): HNYD1-3.7, HNYD1-4, HNYD1-5, HNYD2-3.7, HNYD2-4, HNYD2-5, HNYD5-3.7, HNYD5-4, HNYD5-5, HVY1-3.7, HVY1-4, HVY1-5, HVY2-4, HVY2-5, HVY5-3.7, HVY5-4, HVY5-5 Insulated locking spade crimp connectors, Model(s): LSNYD1-3.7, LSNYD2-3.7, LSNYD5-3.7, LSNYD5-4, LSNYD5-5, LSNYDL1-4, LSNYDL1-5, LSNYDL2-4, LSNYDL2-5 Insulated multiple stud ring type crimp connectors, Model(s): MSRNYD1-3753, MSRNYD2-3753, MSRNYD5-3753 Insulated parallel connectors, Model(s): PVT1, PVT14, PVT2, PVT22, PVTS, PVT8 Insulated pin type connectors, Model(s): PTNYD1-121 PTNYD2-12, PTNYD5-13 Insulated ring type crimp connectors, Model(s): RNYB14-11, RNYB22-11, RNYD1-10, RNYD1-3.2, RNYD1-5, RNYD1-6, RNYD1-8, RNYD2-10, RNYD2-2, RNYD2-3.2, RNYD2-6, RNYD2-8, RNYD5-10, RNYDS-12, RNYD5-3.2, RNYD5-3.7, RNYD5-5, RNYD5-6, RNYD5-8, RNYDL1-3.7, RNYDL1-4, RNYDL2-3.7, RNYDL2-4, RNYDL5-3.7, RNYDL5-4, RNYDM2-3.7, RNYDS1-3.7, RNYDS1-41 RNYDS2-4, RNYDS2- 5, RNYDSS-4, RV1-3.2, RV1-5, RV1-6, RV2-3.2, RV5-10, RV5-3.7, RV5-5, RV5-6, RV5-8, RVL1-4, RVL2-4, RVLS-4, RVM1-3.7, RVM2-3.7, RVY1-3.2 Insulated spade type crimp connectors, Model(s): SNYD1-3.2, SNYD5-3.7, SNYD5-5, SNYDL1-3.7, SNYDL1-4, SNYDL2-3.7, SNYDL2- 4, SNYDL2-5, SNYDL5-4, SNYDLL1-3.7, SNYDLL2-3.7, SNYDM1-4, SNYDM2-4, SNYDS1-5, SNYDS2-5, SVL1-3.7, SVL1-5, SVL2-3.7, SVL2 5, SVM 1-4, SVM2-4, SVY1-3.2, SVY2-3.2, SVY5-3.7, SVY5-5, SVYL1-3.7, SVYL1-4, SVYL2-3.7, SVYL2-4, SVYL2-5, SVYL5-4, SVYLL1-3.7, SVYLL2-3.7, SVYM1-4, SVYM2-4, SVYS1-5, SVYS2-5, SVYS5-4 Y U Insulated splice connectors, Model(s): PB1-, P132-, P135- v U_ LL Insulating caps or covers, for use on manufacturers splice caps, for 2006-5, 2008-5 connectors, Model(s): 2007 Listed pressure cable connectors, Model(s): BHT1, BHT2, BHTS, BN1, BN2, BNS, BNT1-16, BNT14, BNT2-16, BNT22, BNT5-20, BNTB, BNYDF1, BNYDF2, BNYDFS, BNYT1, BNYT2, BNYTS, BV1, BV2 BV5, BVT14, BVT22, BVT8 Listed pressure ring terminal connectors, Model(s): RNYB14-8, RNYB8-11, RNYBL22-5, RNYBL22-6 Listed splicing wire connectors, Model(s): L12, L13, L15 Non -insulated flange spade crimp connectors, Model(s): FSN1-3.7, FSN1-4, FSN1-5, FSN2-3.7, FSN2-41 FSN2-5, FSN5-3.7, FSN5-4, FSN5-5, FSN131-3.7, FSNB1-4, FSN131-5, FSNB2-3.7, FSNB2-4, FSN132-5, FSNB5-3.7, FSN135-4, FSNB5-5, FSNL1-3.7, FSNL2-5 Non -insulated hook crimp connectors, Model(s): HN1-4, HN1-5, HN2 -3.7, HN2 -4, HN2 -5, HN5-3.7, HN5-4, HN5-5 Non -insulated locking type crimp connectors, Model(s): LSN1-3.7, LSN2-3.7, LSN5-3.7, LSN5-4, LSN5-5, LSN5-6, LSNL1-4, LSNL1-5, LSNL2-5 Non -insulated multiple stud ring type crimp connectors, Model(s): MSRNB1-3753 Non -insulated parallel crimp connectors, Model(s): PNT 1, PNT 14, PNT 2, PNT 22, PNT 5, PNT 8, PNT1, PNT2, PNTS Non -insulated pin type crimp connectors, Model(s): PTN1-12, PTN2-12, PTN5-13 Non -insulated ring type crimp connector, Model(s): RNB1-10, RN131-3.2, RNB14-11, RNB14-12, RN1314-16, RNB1-6, RN131-8, RNB2- 10, RNB2-2, RN132-6, RN135-12, RNB8-12, RNBL1-4 Non -insulated ring type crimp connectors, Model(s): RNB1-3.2, RNB14-10, RNB14-5, RNB14-8, RN131-5, RN132-10, RNB22-10, RNB22-12, RNB22-8, RNB2-3.2, RNB2-8, RNB5-10, RNB5-3.2, RNB5-3.7, RNB5-3.7, RNB5-51 RNB5-6, RNB5-8, RNB8-101 RNB8-11, RNB8-16, RNB8-8, RNBL1-3.7, RNBL22-5, RNBL22-6, RNBL2-3.7, RNBL2-5, RNBL38-10, RNBL5-3.7, RNBL5-4, RNBM1-3.7, RNBM1-3.7, RNBM2-3.7, RNBM2-3.7, RNBM8-51 RNBS1-4, RNBS14-5, RNBS2-4, RNBS2-5, RNBS5-4, RNBS8-6 Non -insulated spade type crimp connectors, Model(s): SN1-3.2, SN2-3.2, SN5-3.7, SNS -5, SN131-3.2, SN135-3.7, SN135-5, SNBL1-3.7, SNBL1-4, SNBL2-4, SNBL2-5, SNBL5-4, SNBL5-6, SNBLL1-3.7, SNBLL2-3.7, SNBM1-4, SNBS1-5, SNBS5-4, SNL1-3.7, SNL1-4, SNL2-3.7, SNL2-4, SNL2-5, SNLL1-3.7, SNLL2-3.7, SNM1-4, SNM2-4, SNS1-5, SNS2-5, SNS5-4 Pressure cable connectors, Model(s): KB - 1000, KB - 2/0, KB - 350, KB - 4/0, KB - 500, KB - 800, KS - 1000, KS - 2/0, KS - 350, KS - 4/0, KS - 500, KS - 800 Pressure terminal connectors, Model(s): FSVY1-3.7, FSVY1-4, FSVY1-5, FSVY2-3.7, FSVY2-4, FSVY2-5, FSVY5-3.7, FSVY5-4, FSVY5-5, K-56551 K-5656, LSV1-3.7, LSV2-3.7, LSV5-4, LSV5-5, LSV5-6, LSVL2-4, LSVS1-4, LSVS1-5, LSVS2-5, LSVY1-3.7, LSVY2-3.7, LSVY5-3.7, LSVY5-4, LSVY5-5, LSVY5-6, LSVYL1-4, LSVYL1-5, LSVYL2-4, LSVYL2-5, MSRNB2-3753, MSRVYl-3753, MSRVY2-3753, MSRVY5-3753, PTVY1-12, PTVY2-12, PTVY5-131 RVY1-101 RVY1-5, RVY1-6, RVY1-8, RVY2-10, RVY2-2, RVY2-3.2, RVY2-6, RVY2-8, RVY5-10, RVY5-12, RVY5-3.2, RVY5-3.7, RVY5-5, RVY5-6, RVY5-8, RVYL1-3.7, RVYL1-4, RVYL2-3.7, RVYL2-4, RVYL2-5, RVYL5-3.7, RVYL5-4, RVYM2-3.7, RVYS1-3.7, RVYS1-4, RVYS2-3.7, RVYS2-4, RVYS2-5, RVYS5-4, SNBM2-4, SNYD2-3.2, TLK16-6, TLK25-10 Pressure Terminal Connectors, Model(s): RNYB14-10, RNYB14-12, RNYB14-5, RNY1322-12, RNYB22-8, RNY138-10, RNY138-12, RNY138- 8, RNYBM8-5, RNYBS14-6 Slicing wire connectors, Model(s): OK -2 (Pkg. cat No. 84), OK -3 (Pkg. cat No. 85), OK -4 (Pkg. cat No. 86) OK -5 (Pkg. cat No. 87), OK - 6W (Pkck . cat No. 88), OK-8(Pkck . cat No. 90), OK -8W (NA). Splicing wire connectors, Model(s): 12, 13, 14 14-6, 15, 199, 1995, 200, 2002, 2006-5, 2008-5, 2011-5, 22-10, 22-12, 29, 299, 2995, 30 300, 32, 33, 34, 340, 36, 37, 38, 39, 399, 400 400AL, 42, 50 615069, 66, 70 800, AS -1/0, AS -2, AS -2/0, AS -350, AS -4, AS -4/0, AS -500, AS -6, B1 B2, B4, BT -2, BTC 1/0-10, BTC 1/0-14, BTC 2/0-14, BTC 250-4, BTC 350-1/0, BTC 4/0-10, BTC 4/0-2, BTC 4/0-6, BTC 500-1/0, BT 500-14, BTC 500-4, BTC1/0-10, BTC2/0-14, BTC250-4, BTC350-1/0, BTC4/0-10, BTC4/0-2, BTC4/0-6, BTC500-1/0, BTC500-14, BTC500-4, BV1, BV1, BV2, BV2 BV5, BVS, C=3 CC=4, C=5 Kms, K1000, K2 Kms, K250, K3 K3/0, K350, K4 K500, K6 K750, K8, KS10, R1, S1 /0, 52, LZ S2/0,5250,53, S3L S350,54, S500,56, TR 1, TR 2, W1, W2, W4, WT1, WT2, WT3, WT4, WT6 WTW51, WTW52, WTW53, WTW54 Insulating caps or covers, for use on manufacturers splice caps, for 2011-5 connector, Model(s): 2014 Splicing Wire Connectors, Model(s): BNT11 BNT2 Splicing Wire Connectors% Model(s): 46-404, 46-405 Splicinig wire connectors, Model(s): H-1566, H-1567, H-1570, H-1571, H-1572, H-1591, H-1592, H-1594 Terminal connectors, Model(s): 10, 11 22, 250, 300, 341, 342, 410 with insulating cap No. 415, 411 with insulating cap No. 417.412 with insulating cap No. 417, 451 452, 454 48, 49 49 Black, 53-B, 59B, 600, 71 B#, 72B#, 73B#, 73B+, 74B, 76B 76B+, 78B+, 82 K-5504 LSNL2-4, MM=3, PV3-750, PV3-750, PV3-750, PV4-750, PV4-750, PV4-750, RNBL2-4. RNBS14-6, RNBS38-6, RNBS38-8, RNYB22-10, RNYBS8-6, RV2-6, RVL2-5, SV5-5, WT1, WT2 WT3 WT4 WT41, WT51, WT52. WT53. WT54, WT6 Terminal Connectors, Model(s): RNB22-11 Wire Connectors, Model(s): 69 653 Wire Connectors and Soldering Lugs, Model(s): L22 L23 L25 PS10, PS12, PS2, PS3, P54 PS4S, P55 PS6 PS8 # - The equipment (71 B, 72B and 73B) were also evaluated to the requirements of UL 2043 and are suitable for use in air handling spaces. * - May be followed by suffix B, J, T or X. NOTE - All models may be provided with or without prefix W" or suffix "MP" or "V" and prefix "BP". All models may be followed by suffixes BT, UB or OF with or without a two or four digit number, with or without suffixes B, LP, NP, PF, PH, SP and/or T. Die Series terminals may be followed by Suffixes UI, UT, UF, US, or UB, with or without a two to four digit number, with or without Suffix T or B, followed by Suffixes SP, LP, NP, PF, or and/or NM, by PH or BE, with or without Suffixes NT, BS, and /or G. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL Solutions' Follow - Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL Solutions' Follow - Up Service. Always look for the Mark on the product. UL Solutions permits the reproduction of the material contained in Product iQ subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from Product iQ with permission from UL Solutions" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "©2023 UL LLC." RaCKIT INTRODUCING ROCKIT SMART SLIDE! Introducing EcoFasten's patent pending Rocklt Smart Slide, our simple solution for quickly installing the popular Rocklt rail -less racking system to composition shingle roofs. Features & Benefits • Eliminates the need to pry up shingle courses and install a metal flashing • Multiple opportunities to find the rafter • No need for additional material when architectural shingles are not level • Longer 6.75" slide avoids overlaps in shingle courses • Integrated flashing utilizes UltraGrip TechnologyTM to create a watertight seal Required Components: D���444 D.IVIS/p4, APp�O.,,* O V C FL #39871 G ? D ND d �'s STATE OF p < 0 R ISP„•P��Q DDvvvaa 2011024 RI SMART SLIDE BLK 6.75" 2011025 RI SMART SCRW #12X3" W/BW ROCKIT SMART SLIDE Integrated UltraGrip TechnologyTM Pre-installed sealing pads are compatible with all composition shingle roofs. The compression achieved when fastened to the roof creates a super strong watertight seal. In most cases, the slide can be mounted to the deck without the need for sealant. A layer of flexible foam provides cushioning, which allows the waterproofing sealant to embed deep into the granules of the shingle as well as to flexibly conform over the steps found on architectural -style shingles. VI Testing & Documentation LIDE • UL441 Rain Report • TAS 100 (A)-95 Wind and Wind Driven Rain Resistance • Mechanical Load Test/Structural Capacity Certification • Florida Product Approval • Rocklt Installation Manual • Rocklt CutSheets EcoFQstena 4141 W. VAN BUREN ST, SUITE 2, PHOENIX Az 8 nr, Esdec Solar Group Company 1- 8 7 7- 8 5 9- 3 9 4 7 1 INFO @ E C O F A S T E N S O L A R. C OO M M ;5,60$576/,'(%/.52&.,7)/$6+/(666/,'($66(0%/<$'+(6,9(5(/($6(/,1(5,7(012'(6&5,37,2152&.,760$576/,'($66(0%/<3$57180%(5'(6&5,37,215,60$576/,'(%/.0$7(5,$/$/80,180(3'0$'+(6,9(75($7('3$3(5),1,6+%/$&.5HY&61.317.82.8772.83.0076.2.5514.0.4210.5RI SMART SCREW #12X3" W/BWPART NUMBERDESCRIPTION2011025RI SMART SCREW #12X3" W/BWITEM NO.DESCRIPTION1SELF TAPPING SCREW #12 WITH SEALING WASHER ASSEMBLYMATERIALSTAINLESS STEEL, EPDM RUBBERFINISHMILL, BLACKRev: CS-2