Loading...
VS 29 Primary ENGINEERING CALCULATIONS1 of 65 TABLE OF CONTENTS Project and Site Information ........................................................................................................... -Engineering Methods Explanation (2018 IBC Lateral and Gravity Engineering Calculations Package For Plans Examiner) -Wind Speed Determination - Applied Technology Council -Seismic1 Spectral Response - Applied Technology Council -Satellite Image of Building Site and Surrounding Area -Snow Load Calculation (with Normalized Ground Snow Load Chart if Over 30 psf) Lateral Analysis ................................................................................................................................ -Project Lateral Information - Design Settings and Site Information -Woodworks® Shearwall Lateral Analysis - Layout and Uplift by Floor -Design Summary - Shear Wall Design and Hold Downs -Shear Results for Wind - Critical Response Summary -Shear Results for Seismic - Critical Response Summary -Simpson Strong Wall Design Criteria and Anchorage Calculations (if specified) -Plan Specific Lateral Items Gravity Load Analysis ..................................................................................................................... -Forte® Job Summary Report - List of Beams and Headers -Member Reports - Individual Beams and Headers -Post Capacities Tables -Plan Specific Gravity Items Foundation ........................................................................................................................................ -1500 PSF Reinforced Concrete Pad Calculations -Continuous Concrete Footing with Stem Point Load Engineering -Restrained Retaining Walls if Present -Unrestrained Retaining Walls if Present -Plan Specific Foundation Items 1 2018 International Building Code (IBC) 2 of 65 2018 IBC Lateral and Gravity Engineering Calculations Package For Plans Examiner This engineering calculations package contains the lateral and gravity load engineering as noted in the engineering scope. All engineered load bearing structural members are specified on the full size engineering sheets. The enclosed engineering calculations document the engineering analysis. The engineering calculations are not required to be referenced onsite for construction. These calculations are to demonstrate to the Plans Examiner that the engineering was completed following the 2018 IBC. The cover sheet of the engineering specifies the engineering scope as lateral and gravity load engineering. LATERAL ENGINEERING: Lateral engineering involves determining what the seismic and wind loads are according to ASCE 7-16. Applying these loads to the structure, and determining the design of the lateral structural elements to resist these loads. The structural elements are sheathing, nailing, holdowns, and the connections between loaded members and shear resisting elements. Lateral load modeling was completed with Wood Works Design Office 12 (www.woodworks- software.com 800-844-1275). Wood Works was developed in conjunction with the American Forest & Paper Association. The AF&PA is the same professional organization that produces the National Design Specification (NDS) for Wood Construction, the Allowable Stress Design (ASD) manual for engineered wood construction, Wood Frame Construction Manual (WFCM) for one-and two-family dwellings, and the Load and Resistance Factor Design (LFRD) manual for engineered wood construction. The AF&PA "wrote the manuals" all engineers use. Seismic: Seismic load engineering follows the ASCE 7-16 12.8 equivalent lateral force procedure. Per ASCE 7 the analysis consists of the application of equivalent static lateral forces to a linear mathematical model of the structure. The total forces applied in each direction are the total base shear. Refer to ASCE 7-16 12.8 for a detailed description of this procedure. The engineering calculations include a USGS determination of the seismic spectral response accelerations. These numbers, S1 and Ss, are used in the lateral model to determine seismic loading to the shearwalls. Woodworks Design Office was used to make the linear mathematical model specified by ASCE 7-16 section 12.8. Wind: Wind load engineering follows the ASCE 7-16 Directional method for all heights. The wind loading is determined from the wind exposure and wind speed. This loading is applied to surfaces of the structure as modeled. Total loadings for each shear line, wall line, and full height shearwall are determined. Required shear strengths for each shearwall are calculated then sheathing and nailing patterns are chosen to resist design loads. Holdowns are applied where the nailing of the OSB sheathing to the mudsill or lower floor is not adequate to resist shear panel overturning. GRAVITY LOAD ENGINEERING: Gravity loads from snow, structure, occupants, etc. meeting the requirements of the 2018 IBC have been traced through the structure. Refer to the legend on the engineering sheets showing how the point and line loads are depicted. All loads are supported and traced through the structure. Load supporting members have been numbered for reference back to the engineering calculations. Loads to the foundation or soil have reinforced footings specified where required. 3 of 65 ASCE 7 Hazards Report Address: No Address at This Location Standard:ASCE/SEI 7-16 Latitude:46.93562 Risk Category:II Longitude:-122.61306 Soil Class:D - Default (see Section 11.4.3) Elevation:351.31595764630976 ft (NAVD 88) Wind Results: Wind Speed 97 Vmph 10-year MRI 67 Vmph 25-year MRI 73 Vmph 50-year MRI 77 Vmph 100-year MRI 83 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Mon Aug 21 2023 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 4https://asce7hazardtool.online/Mon Aug 21 20234 of 65 SS : 1.286 S1 : 0.466 F a : 1.2 F v : N/A SMS : 1.544 SM1 : N/A SDS : 1.029 SD1 : N/A T L : 16 PGA : 0.512 PGA M : 0.614 F PGA : 1.2 Ie : 1 C v : 1.357 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Mon Aug 21 2023 Page 2 of 4https://asce7hazardtool.online/Mon Aug 21 20235 of 65 Flood Results: Data Source: Date Accessed: FIRM Panel: Insurance Study Note: Flood Zone Categorization: X (unshaded) Base Flood Elevation: FEMA National Flood Hazard Layer - Effective Flood Hazard Layer for US, where modernized (https://msc.fema.gov/portal/search) Mon Aug 21 2023 If available, download FIRM panel here Download FEMA Flood Insurance Study for this area here Page 3 of 4https://asce7hazardtool.online/Mon Aug 21 20236 of 65 The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. Page 4 of 4https://asce7hazardtool.online/Mon Aug 21 20237 of 65 Hodge Engineering, Inc. John E. Hodge P. E. 3733 Rosedale St, Suite 200, Gig Harbor, WA 98335 (253) 857-7055 ASCE 7-16: Snow Loading Calculation Site: Lot 29 – 10402 Calder St SE, Yelm, WA 98597 Plan: Vista in Yelm - Primary Job: 230371 Three resources for determining snow load: 1. Snow Load Analysis for Washington; 2nd Edition by the Structural Engineers Association of Washington (SEAW). “This edition provides a large color map for each half of the state, with normalized ground snow load isolines and elevation contours to help readily determine the ground snow load anywhere in the state”. 2. WABO/SEAW White Paper #8 “Guidelines for Determining Snow Loads in Washington State” available on www.seaw.org/publications 3. ASCE 7-16 Chapter 7 Snow Loads Ground Snow Load pg: (ASCE 7-16 7.2 Extreme value statistical analysis using 2% annual probability of being exceeded) Normalized ground snow load (NGSL) = 0.050 Lot Elevation = 355 ft. from Google Earth 1. Ground snow load = NGSL x elevation = 0.050 * 355 = 18 psf = pg 2. SEAW Snow Load Analysis for Washington Appendix A = Yelm – 18 PSF (@340 FT) Roof Snow Load pf: ASCE 7-16 7.3 Flat roof snow load pf = 0.7CeCtIspg ASCE 7-16 7.3.1 Ce is the exposure factor = 1.0 for partially exposed structure (table 7.3-1) ASCE 7-16 7.3.2 Ct is the thermal factor = 1.1 for heated residences (table 7.3-2) ASCE 7-16 7.3.3 Is is the importance factor = 1.0 for residences (table 1.5-1) ASCE 7-16 7.4 Sloped roof snow loads - no roof slope reduction Cs taken unless noted otherwise ASCE 7-16 7.6 Trussed roof or slope exceeding 7:12 – no unbalanced snow loading pf = 0.7CeCtIpg = 0.7 * 1.0 * 1.1 * 1.0 * 18 pg = 14 psf Flat Roof Snow Load Minimum roof snow load 25 psf., U.N.O. “Snow load to be approved by the authority having jurisdiction…” ASCE 7-16 7.2 8 of 65 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 2019 (Update 3) 230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 13:07:03 Project Information DESIGN SETTINGS Design Code IBC 2018/AWC SDPWS 2015 Wind Standard ASCE 7-16 Directional (All heights) Seismic Standard ASCE 7-16 Load Combinations For Design (ASD) 0.70 Seismic 0.60 Wind For Deflection (Strength) 1.00 Seismic 1.00 Wind Building Code Capacity Modification Wind Seismic 1.00 1.00 Service Conditions and Load Duration Duration Factor - Temperature Range - Moisture Content Fabrication Service 19% (<=19%)10% (<=19%) Max Shearwall Offset [ft] Plan (within story) 4.00 Elevation (between stories) 3.17 Maximum Height-to-width Ratio Wood panels Wind Seismic Fiberboard Lumber Wind Seismic Gypsum Blocked Unblocked 3.5 3.5 - - - - - Ignore non-wood-panel shear resistance contribution... Wind Seismic when comb'd w/ wood panels Always Forces based on... Hold-downs Applied loads Drag struts Applied loads Shearwall relative rigidity: Wall capacity Perforated shearwall Co factor: SDPWS Equation 4.3-5 Non-identical materials and construction on the shearline: Not allowed Deflection Equation: 4-term from SDPWS C4.3.2-1 Drift limit for wind design: 1 / 500 story height Force-transfer strap: Continuous at top of highest opening and bottom of lowest SITE INFORMATION Risk Category Category II - All others Wind ASCE 7-16 Directional (All heights) Seismic ASCE 7-16 12.8 Equivalent Lateral Force Procedure Design Wind Speed 97 mph Exposure Exposure B Enclosure Enclosed Structure Type Regular Building System Bearing Wall Design Category D Site Class D Topographic Information [ft] Shape - Height - Length - Site Location: - Elev: 350ft Rigid building - Static analysis Spectral Response Acceleration S1: 0.470g Ss: 1.290g Fundamental Period E-W N-S T Used 0.200s 0.200s Approximate Ta 0.200s 0.200s Maximum T 0.280s 0.280s Response Factor R 6.50 6.50 Fa: 1.20 Fv: 1.83 Case 2 N-S loadsE-W loads Eccentricity (%)15 15 Loaded at 75% Min Wind Loads: Walls Roofs 16 psf 8 psf Serviceability Wind Speed 83 mph 1 9 of 65 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 2019 (Update 3)230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 09:27:33 0'1.67'3.33'5'6.67'8.33'10'11.67'13.33'15'16.67'18.33'20'21.67'23.33'25'26.67'28.33'30' -5' -3.33' -1.67' 0' 1.67' 3.33' 5' 6.67' 8.33' 10' 11.67' 13.33' 15' 16.67' 18.33' 20' 21.67' 23.33' 25' 26.67' 28.33' 30' 31.67' 33.33' 35' 36.67' C-1 4-1A-31-1A-1 3-1A-22-11387 1387 1118980773911111898077391113831383554627516554627516 1186118634633734633713051305329329329329Loads: Directional Case 1 Wind (W); Forces: 0.6W + 0.6D; Flexible distribution Vertical element required C Compression force exists Factored holddown force (lbs) Factored shearline force (lbs) Applied point load or discontinuous shearline force (lbs) Unfactored uplift wind load (plf,lbs) Unfactored dead load (plf,lbs) Unfactored applied shear load (plf) Level 2 of 2 10 of 65 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 2019 (Update 3)230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 09:27:33 0'1.67'3.33'5'6.67'8.33'10'11.67'13.33'15'16.67'18.33'20'21.67'23.33'25'26.67'28.33'30' -5' -3.33' -1.67' 0' 1.67' 3.33' 5' 6.67' 8.33' 10' 11.67' 13.33' 15' 16.67' 18.33' 20' 21.67' 23.33' 25' 26.67' 28.33' 30' 31.67' 33.33' 35' 36.67' C-1 4-1A-31-1A-1 3-1A-22-11853 149413091033121714941309103312171736 69578764769578764717024974844974841887476475476475Loads: Seismic (Qe); Forces: 0.7E + 0.6D; E = pQe + 0.2 Sds D; p(NS) = 1.0; p(EW) = 1.0; Sds = 1.0; Flexible distribution Vertical element required C Compression force exists Factored holddown force (lbs) Factored shearline force (lbs) Applied point load or discontinuous shearline force (lbs) Unfactored dead load (plf,lbs) Unfactored applied shear load (plf) Level 2 of 2 11 of 65 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 2019 (Update 3)230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 09:27:33 0'1.67'3.33'5'6.67'8.33'10'11.67'13.33'15'16.67'18.33'20'21.67'23.33'25'26.67'28.33' -3.33' -1.67' 0' 1.67' 3.33' 5' 6.67' 8.33' 10' 11.67' 13.33' 15' 16.67' 18.33' 20' 21.67' 23.33' 25' 26.67' 28.33' 30' 31.67' 33.33' 35' 36.67' C-2 4-1A-31-1A-2 2-1B-1 A-1 C-1 C-3 2439 24391161002980773667313773116100221179801495773252832366673131495773252815611561119511952113211355434428320608516554757344283127013122060875451624932493346337754346106811017313372594 2594329329329329329806821329329806329821Loads: Directional Case 1 Wind (W); Forces: 0.6W + 0.6D; Flexible distribution Vertical element required C Compression force exists Factored holddown force (lbs) Factored shearline force (lbs) Applied point load or discontinuous shearline force (lbs) Unfactored uplift wind load (plf,lbs) Unfactored dead load (plf,lbs) Unfactored applied shear load (plf) Level 1 of 2 12 of 65 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 2019 (Update 3)230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 09:27:33 0'1.67'3.33'5'6.67'8.33'10'11.67'13.33'15'16.67'18.33'20'21.67'23.33'25'26.67'28.33' -3.33' -1.67' 0' 1.67' 3.33' 5' 6.67' 8.33' 10' 11.67' 13.33' 15' 16.67' 18.33' 20' 21.67' 23.33' 25' 26.67' 28.33' 30' 31.67' 33.33' 35' 36.67' C-2 4-1A-31-1A-2 2-1B-1 A-1 C-1 C-3 24451561338130910338914181033156133821231309149910332839361789141814991033283960646446421836954323552576364769578343235514271478257637796472527497484765497122512617414842708476475476475476841857475476841475857 Loads: Seismic (Qe); Forces: 0.7E + 0.6D; E = pQe + 0.2 Sds D; p(NS) = 1.0; p(EW) = 1.0; Sds = 1.0; Flexible distribution Vertical element required C Compression force exists Factored holddown force (lbs) Factored shearline force (lbs) Applied point load or discontinuous shearline force (lbs) Unfactored dead load (plf,lbs) Unfactored applied shear load (plf) Level 1 of 2 13 of 65 WoodWorks® Shearwalls 230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 13:07:03 Structural Data STORY INFORMATION Hold-down Story Floor/Ceiling Wall Length subject to Bolt Elev [ft]Depth [in]Height [ft]shrinkage [in]length [in] Ceiling 20.79 0.0 Level 2 12.79 12.0 8.00 15.7 16.5 Level 1 2.79 9.5 9.00 13.2 14.0 Foundation 2.00 BLOCK and ROOF INFORMATION Block Roof Panels Dimensions [ft]Face Type Slope Overhang [ft] Block 1 2 Story N-S Ridge Location X,Y =0.00 1.92 North Gable 90.0 2.00 Extent X,Y =28.08 33.08 South Hip 26.6 2.00 Ridge X Location, Offset 14.04 0.00 East Side 26.6 2.00 Ridge Elevation, Height 27.81 7.02 West Side 26.6 2.00 Block 2 2 Story N-S Ridge Location X,Y =11.00 -0.58 North Joined 153.4 2.00 Extent X,Y =17.00 2.50 South Gable 90.0 2.00 Ridge X Location, Offset 19.50 0.00 East Side 26.5 2.00 Ridge Elevation, Height 25.03 4.24 West Side 26.5 2.00 Block 3 2 Story N-S Ridge Location X,Y =16.50 -1.58 North Joined 90.0 2.00 Extent X,Y =11.50 1.00 South Gable 90.0 2.00 Ridge X Location, Offset 22.25 0.00 East Side 26.6 2.00 Ridge Elevation, Height 23.67 2.87 West Side 26.6 2.00 Block 4 1 Story N-S Ridge Location X,Y =5.50 -3.83 North Gable 90.0 0.00 Extent X,Y =6.00 5.67 South Gable 90.0 2.00 Ridge X Location, Offset 8.50 0.00 East Side 26.5 2.00 Ridge Elevation, Height 14.29 1.50 West Side 26.5 2.00 2 14 of 65 WoodWorks® Shearwalls 230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 13:07:03 SHEATHING MATERIALS by WALL GROUP Sheathing Fasteners Apply Grp Surf Material Ratng Thick GU Ply Or Gvtv Size Type Df Eg Fd Bk Notes in in lbs/in in in 1 Ext Struct Sh OSB 24/16 7/16 --Vert 83500 8d Nail N 4 12 Y 1,2,3 2 Ext Struct Sh OSB 24/16 7/16 --Vert 83500 8d Nail N 6 12 Y 1,3 Legend: Grp – Wall Design Group number, used to reference wall in other tables (created by program) Surf – Exterior or interior surface when applied to exterior wall Ratng – Span rating, see SDPWS Table C4.2.2.2C Thick – Nominal panel thickness GU - Gypsum underlay thickness Ply – Number of plies (or layers) in construction of plywood sheets Or – Orientation of longer dimension of sheathing panels Gvtv – Shear stiffness in lb/in. of depth from SDPWS Tables C4.2.2A-B Type – Fastener type from SDPWS Tables 4.3A-D: Nail – common wire nail for structural panels and lumber, cooler or gypsum wallboard nail for GWB, plasterboard nail for gypsum lath, galvanised nail for gypsum sheathing; Box - box nail; Casing – casing nail; Roof – roofing nail; Screw – drywall screw Size - Common, box, and casing nails: refer to SDPWS Table A1 (casing sizes = box sizes). Gauges: 11 ga = 0.120” x 1-3/4” (gypsum sheathing, 25/32” fiberboard ), 1-1/2” (lath & plaster, 1/2” fiberboard); 13 ga plasterboard = 0.92” x 1- 1/8”. Cooler or gypsum wallboard nail: 5d = .086” x 1-5/8”; 6d = .092” x 1-7/8”; 8d = .113” x 2-3/8”; 6/8d = 6d base ply, 8d face ply for 2-ply GWB. Drywall screws: No. 6, 1-1/4” long. 5/8” gypsum sheathing can also use 6d cooler or GWB nail Df – Deformed nails ( threaded or spiral), with increased withdrawal capacity Eg – Panel edge fastener spacing Fd – Field spacing interior to panels Bk – Sheathing is nailed to blocking at all panel edges; Y(es) or N(o) Apply Notes – Notes below table legend which apply to sheathing side Notes: 1.Capacity has been reduced for framing specific gravity according to SDPWS T4.3A Note 3. 2. Framing at adjoining panel edges must be 3" nominal or wider with staggered nailing according to SDPWS 4.3.7.1.4 3. Shear capacity for current design has been increased to the value for 15/32" sheathing with same nailing because stud spacing is 16" max. or panel orientation is horizontal. See SDPWS T4.3A Note 2. FRAMING MATERIALS and STANDARD WALL by WALL GROUP Wall Species Grade b d Spcg SG E Standard Wall Grp in in in psi^6 1 Hem-Fir Stud 1.50 5.50 16 0.43 1.20 2 Hem-Fir Stud 1.50 5.50 16 0.43 1.20 Legend: Wall Grp – Wall Design Group b – Stud breadth (thickness) d – Stud depth (width) Spcg – Maximum on-centre spacing of studs for design, actual spacing may be less. SG – Specific gravity E – Modulus of elasticity Standard Wall - Standard wall designed as group. Notes: Check manufacture requirements for stud size, grade and specific gravity (G) for all shearwall hold-downs. 3 15 of 65 WoodWorks® Shearwalls 230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 13:07:03 SHEARLINE, WALL and OPENING DIMENSIONS North-south Type Wall Location Extent [ft]Length FHS Aspect Height Shearlines Group X [ft]Start End [ft] [ft] Ratio [ft] Line 1 Level 2 Line 1 2 0.00 2.00 35.00 33.00 28.00 - 8.00 Wall 1-1 Seg 2 0.00 2.00 35.00 33.00 28.00 - - Segment 1 -- 2.00 26.33 24.33 - 0.33 - Opening 1 -- 26.33 31.33 5.00 - - 2.00 Segment 2 -- 31.33 35.00 3.67 - 2.18 - Level 1 Line 1 2 0.00 2.00 35.00 33.00 31.00 - 9.00 Wall 1-1 Seg 2 0.00 2.00 35.00 33.00 31.00 - - Segment 1 -- 2.00 8.17 6.17 - 1.46 - Opening 1 -- 8.17 10.17 2.00 - - 2.00 Segment 2 -- 10.17 35.00 24.83 - 0.36 - Line 2 Level 2 Line 2 NSW 11.00 0.00 2.00 2.00 0.00 - 8.00 Wall 2-1 NSW 11.00 0.00 2.00 2.00 0.00 1.00 - Level 1 Line 2 NSW 11.00 0.00 2.00 2.00 0.00 - 9.00 Wall 2-1 NSW 11.00 0.00 2.00 2.00 0.00 1.00 - Line 3 Level 2 Line 3 NSW 16.50 -1.50 0.00 1.50 0.00 - 8.00 Wall 3-1 NSW 16.50 -1.50 0.00 1.50 0.00 1.00 - Line 4 Level 2 Line 4 2 28.00 -1.50 35.00 36.50 32.25 - 8.00 Wall 4-1 Seg 2 28.00 -1.50 35.00 36.50 32.25 - - Segment 1 -- -1.50 14.50 16.00 - 0.50 - Opening 1 -- 14.50 18.75 4.25 - - 2.00 Segment 2 -- 18.75 35.00 16.25 - 0.49 - Level 1 Line 4 2 28.00 0.00 35.00 35.00 29.33 - 9.00 Wall 4-1 Seg 2 28.00 0.00 35.00 35.00 29.33 - - Segment 1 -- 0.00 21.08 21.08 - 0.43 - Opening 1 -- 21.08 23.08 2.00 - - 2.00 Segment 2 -- 23.08 31.33 8.25 - 1.09 - Opening 2 -- 31.33 33.33 2.00 - - 2.00 Segment 3 -- 33.33 35.00 1.67 - 5.40 - East-west Type Wall Location Extent [ft]Length FHS Aspect Height Shearlines Group Y [ft]Start End [ft] [ft] Ratio [ft] Line A Level 2 Line A 2 0.17 0.00 28.00 28.00 12.50 - 8.00 Wall A-1 Seg 2 2.00 0.00 11.00 11.00 7.00 - - Segment 1 -- 0.00 3.75 3.75 - 2.13 - Opening 1 -- 3.75 7.75 4.00 - - 2.00 Segment 2 -- 7.75 11.00 3.25 - 2.46 - Wall A-2 Seg 2 0.00 11.00 16.50 5.50 0.00 - - Segment 1 -- 11.00 12.17 1.17 - 6.86 - Opening 1 -- 12.17 15.17 3.00 - - 2.00 Segment 2 -- 15.17 16.50 1.33 - 6.00 - Wall A-3 Seg 2 -1.50 16.50 28.00 11.50 5.50 - - Segment 1 -- 16.50 19.00 2.50 - 3.20 - Opening 1 -- 19.00 25.00 6.00 - - 2.00 Segment 2 -- 25.00 28.00 3.00 - 2.67 - Level 1 Line A 1 0.79 0.00 28.00 28.00 12.50 - 9.00 Wall A-1 FT 1 2.00 0.00 6.75 6.75 6.75 - - Segment 1 -- 0.00 1.83 1.83 - 2.18 - Opening 1 -- 1.83 3.83 2.00 - - 4.00 Segment 2 -- 3.83 6.75 2.92 - 1.37 - Wall A-2 Seg 1 2.00 6.75 11.00 4.25 0.00 - - Segment 1 -- 6.75 6.92 0.17 - 54.00 - Opening 1 -- 6.92 9.92 3.00 - - 2.00 Segment 2 -- 9.92 11.00 1.08 - 8.31 - Wall A-3 Seg 1 0.00 11.00 28.00 17.00 5.75 - - Segment 1 -- 11.00 13.75 2.75 - 3.27 - Opening 1 -- 13.75 25.00 11.25 - - 2.00 4 16 of 65 WoodWorks® Shearwalls 230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 13:07:03 SHEARLINE, WALL and OPENING DIMENSIONS (continued) Segment 2 -- 25.00 28.00 3.00 - 3.00 - Line B Level 1 Line B Seg 2 19.00 0.00 28.00 28.00 12.00 - 9.00 Wall B-1 Seg 2 19.00 12.00 24.00 12.00 12.00 0.75 - Line C Level 2 Line C 2 35.00 0.00 28.00 28.00 19.25 - 8.00 Wall C-1 Seg 2 35.00 0.00 28.00 28.00 19.25 - - Segment 1 -- 0.00 3.33 3.33 - 2.40 - Opening 1 -- 3.33 7.75 4.42 - - 2.00 Segment 2 -- 7.75 20.58 12.83 - 0.62 - Opening 2 -- 20.58 24.92 4.33 - - 2.00 Segment 3 -- 24.92 28.00 3.08 - 2.59 - Level 1 Line C 2 35.00 0.00 28.00 28.00 25.67 - 9.00 Wall C-1 FT 2 35.00 0.00 11.42 11.42 11.42 - - Segment 1 -- 0.00 4.00 4.00 - 1.13 - Opening 1 -- 4.00 8.00 4.00 - - 4.50 Segment 2 -- 8.00 11.42 3.42 - 1.32 - Wall C-2 Seg 2 35.00 11.42 13.75 2.33 0.00 - - Segment 1 -- 11.42 11.58 0.17 - 54.00 - Opening 1 -- 11.58 13.58 2.00 - - 8.00 Segment 2 -- 13.58 13.75 0.17 - 54.00 - Wall C-3 FT 2 35.00 13.75 28.00 14.25 14.25 - - Segment 1 -- 13.75 17.75 4.00 - 1.13 - Opening 1 -- 17.75 23.75 6.00 - - 4.50 Segment 2 -- 23.75 28.00 4.25 - 1.06 - Legend: Type - Seg = segmented, Prf = perforated, FT = force-transfer, NSW = non-shearwall Location - Dimension perpendicular to wall FHS - Length of full-height sheathing used to resist shear force. For perforated walls, it is based on the factored segments Li defined in SDPWS 4.3.4.3 Aspect Ratio – Ratio of wall height to segment length (h/bs), for force-transfer walls, the aspect ratio of the central pier Wall Group - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall If two wall group numbers listed, they are for rigid diaphragm and flexible diaphragm design. 5 17 of 65 WoodWorks® Shearwalls 230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 13:07:03 Design Summary SHEARWALL DESIGN Wind Shear Loads, Flexible Diaphragm All shearwalls have sufficient design capacity. Seismic Loads, Flexible Diaphragm All shearwalls have sufficient design capacity. HOLDDOWN DESIGN Wind Loads, Flexible Diaphragm All hold-downs have sufficient design capacity. Seismic Loads, Flexible Diaphragm All hold-downs have sufficient design capacity. Refer to the Deflection table for possible issues regarding fastener slippage (SDPWS Table C4.2.2D) for walls that otherwise pass. 6 18 of 65 WoodWorks® Shearwalls 230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 13:07:03 Flexible Diaphragm Wind Design ASCE 7 Directional (All Heights) Loads SHEAR RESULTS N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 - Both - - 1186 - - - 339 - - 9375 - Wall 1-1 2 Both - - 1186 - 1.0 - 339 - - 9375 - Seg. 1 - Both 42.8 0.0 1042 - 1.0 - 339 - 339 8237 0.13 Seg. 2 - Both 39.3 0.0 144 - .92 - 310 - 310 1138 0.13 Level 1 Ln1, Lev1 - Both - - 2493 - - - 339 - - 10494 - Wall 1-1 2 Both - - 2493 - 1.0 - 339 - - 10494 - Seg. 1 - Both 80.4 0.0 496 - 1.0 - 339 - 339 2088 0.24 Seg. 2 - Both 80.4 0.0 1997 - 1.0 - 339 - 339 8407 0.24 Line 4 Level 2 Ln4, Lev2 - Both - - 1305 - - - 339 - - 10917 - Wall 4-1 2 Both - - 1305 - 1.0 - 339 - - 10917 - Seg. 1 - Both 40.5 0.0 647 - 1.0 - 339 - 339 5416 0.12 Seg. 2 - Both 40.5 0.0 657 - 1.0 - 339 - 339 5501 0.12 Level 1 Ln4, Lev1 - Both - - 2594 - - - 339 - - 9930 - Wall 4-1 2 Both - - 2594 - 1.0 - 339 - - 9930 - Seg. 1 - Both 88.4 0.0 1865 - 1.0 - 339 - 339 7137 0.26 Seg. 2 - Both 88.4 0.0 730 - 1.0 - 339 - 339 2793 0.26 Seg. 3 - Both 0.0 0.0 0 - 1.0 - 339 - 339 - - E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 2 LnA, Lev2 - Both - - 1387 - - - 339 - - 3375 - Wall A-1 2 Both - - 857 - 1.0 - 339 - - 2084 - Seg. 1 - Both 130.5 0.0 489 - .94 - 317 - 317 1190 0.41 Seg. 2 - Both 113.1 0.0 368 - .81 - 275 - 275 894 0.41 Wall A-2 2 Both 0.0 - 0 - 1.0 - 339 - - - - Wall A-3 2 Both - - 531 - 1.0 - 339 - - 1291 - Seg. 1 - Both 87.0 0.0 217 - .63 - 212 - 212 529 0.41 Seg. 2 - Both 104.4 0.0 313 - .75 - 254 - 254 762 0.41 Level 1 LnA, Lev1 - Both - - 2439 - - - 495 - - 5085 - Wall A-1 1 Both - - 1529 - 1.0 - 495 - - 3264 - Seg. 1 - Both 321.9 150.2 590 - .92 - 454 - 454 831 0.71 Open. 1 - Both - 407.8 816 - - - 495 - 495 990 0.82 Seg. 2 - Both 321.9 150.2 939 - 1.0 - 495 - 495 1443 0.65 Wall A-2 1 Both 0.0 - 0 - 1.0 - 495 - - - - Wall A-3 1 Both - - 910 - 1.0 - 495 - - 1821 - Seg. 1 - Both 151.0 0.0 415 - .61 - 302 - 302 831 0.50 Seg. 2 - Both 164.7 0.0 494 - .67 - 330 - 330 990 0.50 Line B LnB, Lev1 - Both - - 1561 - - - 339 - - 4062 - Wall B-1 2 Both 130.0 - 1561 - 1.0 - 339 - 339 4062 0.38 Line C Level 2 LnC, Lev2 - Both - - 1383 - - - 339 - - 6089 - Wall C-1 2 Both - - 1383 - 1.0 - 339 - - 6089 - Seg. 1 - Both 64.1 0.0 214 - .83 - 282 - 282 940 0.23 Seg. 2 - Both 76.9 0.0 987 - 1.0 - 339 - 339 4344 0.23 Seg. 3 - Both 59.3 0.0 183 - .77 - 261 - 261 805 0.23 Level 1 LnC, Lev1 - Both - - 2113 - - - 339 - - 8689 - Wall C-1 2 Both - - 940 - 1.0 - 339 - - 3865 - Seg. 1 - Both 126.7 37.9 507 - 1.0 - 339 - 339 1354 0.37 Open. 1 - Both - 164.6 658 - - - 339 - 339 1354 0.49 Seg. 2 - Both 126.7 37.9 433 - 1.0 - 339 - 339 1157 0.37 Wall C-2 2 Both 0.0 - 0 - 1.0 - 339 - - - - Wall C-3 2 Both - - 1173 - 1.0 - 339 - - 4824 - Seg. 1 - Both 142.2 22.4 569 - 1.0 - 339 - 339 1354 0.42 7 19 of 65 WoodWorks® Shearwalls 230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 13:07:03 SHEAR RESULTS (flexible wind design, continued) Open. 1 - Both - 164.6 988 - - - 339 - 339 2031 0.49 Seg. 2 - Both 142.2 22.4 604 - 1.0 - 339 - 339 1439 0.42 Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir - Direction of wind force along shearline. v - Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.4.3 Force-transfer walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier: Aspect ratio adjustment from SDPWS 4.3.3.4.1 Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "S" indicates that the wind design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. 8 20 of 65 WoodWorks® Shearwalls 230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 13:07:03 Flexible Diaphragm Seismic Design SEISMIC INFORMATION Level Mass Area Story Shear [lbs]Diaphragm Force [lbs] [lbs][sq.ft]E-W N-S E-W:Fpx Design N-S:Fpx Design 2 26630 975.3 5127 5127 3848 3848 3848 3848 1 21974 958.0 2350 2350 3175 3175 3175 3175 All 48604 - 7478 7478 - - - - Legend: Mass – Sum of all generated and input building masses on level = wx in ASCE 7 equation 12.8-12. Story Shear – Total unfactored (strength-level) shear force induced at level x, = Fx in ASCE 7 equation 12.8-11. Diaphragm Force – Minimum ASD-factored force for diaphragm design, used by Shearwalls only for drag strut forces, as per Exception to 12.10.2.1. Fpx is from Eqns. 12.10-1, -2, and -3. Design = The greater of the story shear and Fpx + transfer forces from discontinuous shearlines, factored by overstrength (omega) as per 12.10.1.1. Omega = 2.5 as per 12.2-1. Redundancy Factor p (rho): E-W 1.00, N-S 1.00 Automatically calculated according to ASCE 7 12.3.4.2. Vertical Earthquake Load Ev Ev = 0.2 Sds D; Sds = 1.00; Ev = 0.200 D unfactored; 0.140 D factored; total dead load factor: 0.6 - 0.140 = 0.460 tension, 1.0 + 0.140 = 1.140 compression. 9 21 of 65 WoodWorks® Shearwalls 230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 13:07:03 SHEAR RESULTS (flexible seismic design) N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 - Both - - 1702 - - - 242 - - 6697 - Wall 1-1 2 Both - - 1702 - 1.0 - 242 - - 6697 - Seg. 1 - Both 61.5 0.0 1495 - 1.0 - 242 - 242 5884 0.25 Seg. 2 - Both 56.3 0.0 207 - .92 - 222 - 222 813 0.25 Level 1 Ln1, Lev1 - Both - - 2527 - - - 242 - - 7496 - Wall 1-1 2 Both - - 2527 - 1.0 - 242 - - 7496 - Seg. 1 - Both 81.5 0.0 503 - 1.0 - 242 - 242 1491 0.34 Seg. 2 - Both 81.5 0.0 2024 - 1.0 - 242 - 242 6005 0.34 Line 4 Level 2 Ln4, Lev2 - Both - - 1887 - - - 242 - - 7798 - Wall 4-1 2 Both - - 1887 - 1.0 - 242 - - 7798 - Seg. 1 - Both 58.5 0.0 936 - 1.0 - 242 - 242 3869 0.24 Seg. 2 - Both 58.5 0.0 951 - 1.0 - 242 - 242 3929 0.24 Level 1 Ln4, Lev1 - Both - - 2708 - - - 242 - - 7093 - Wall 4-1 2 Both - - 2708 - 1.0 - 242 - - 7093 - Seg. 1 - Both 92.3 0.0 1946 - 1.0 - 242 - 242 5098 0.38 Seg. 2 - Both 92.3 0.0 762 - 1.0 - 242 - 242 1995 0.38 Seg. 3 - Both 0.0 0.0 0 - 1.0 - 242 - 242 - - E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 2 LnA, Lev2 - Both - - 1853 - - - 242 - - 2410 - Wall A-1 2^Both - - 1145 - 1.0 - 242 - - 1489 - Seg. 1 - Both 174.3 0.0 654 - .94 - 227 - 227 850 0.77 Seg. 2 - Both 151.1 0.0 491 - .81 - 196 - 196 639 0.77 Wall A-2 2 Both 0.0 - 0 - 1.0 - 242 - - - - Wall A-3 2^Both - - 709 - 1.0 - 242 - - 922 - Seg. 1 - Both 116.2 0.0 291 - .63 - 151 - 151 378 0.77 Seg. 2 - Both 139.4 0.0 418 - .75 - 181 - 181 544 0.77 Level 1 LnA, Lev1 - Both - - 2445 - - - 353 - - 3632 - Wall A-1 1 Both - - 1533 - 1.0 - 353 - - 2331 - Seg. 1 - Both 322.8 150.6 592 - .92 - 324 - 324 594 1.00 Open. 1 - Both - 408.9 818 - - - 353 - 353 707 1.16 Seg. 2 - Both 322.8 150.6 942 - 1.0 - 353 - 353 1031 0.91 Wall A-2 1 Both 0.0 - 0 - 1.0 - 353 - - - - Wall A-3 1^Both - - 912 - 1.0 - 353 - - 1301 - Seg. 1 - Both 151.4 0.0 416 - .61 - 216 - 216 594 0.70 Seg. 2 - Both 165.2 0.0 496 - .67 - 236 - 236 707 0.70 Line B LnB, Lev1 - Both - - 606 - - - 242 - - 2902 - Wall B-1 2 Both 50.5 - 606 - 1.0 - 242 - 242 2902 0.21 Line C Level 2 LnC, Lev2 - Both - - 1736 - - - 242 - - 4349 - Wall C-1 2 Both - - 1736 - 1.0 - 242 - - 4349 - Seg. 1 - Both 80.4 0.0 268 - .83 - 202 - 202 672 0.40 Seg. 2 - Both 96.5 0.0 1238 - 1.0 - 242 - 242 3103 0.40 Seg. 3 - Both 74.4 0.0 229 - .77 - 186 - 186 575 0.40 Level 1 LnC, Lev1 - Both - - 2183 - - - 242 - - 6206 - Wall C-1 2 Both - - 971 - 1.0 - 242 - - 2761 - Seg. 1 - Both 130.9 39.2 524 - 1.0 - 242 - 242 967 0.54 Open. 1 - Both - 170.1 681 - - - 242 - 242 967 0.70 Seg. 2 - Both 130.9 39.2 447 - 1.0 - 242 - 242 826 0.54 Wall C-2 2 Both 0.0 - 0 - 1.0 - 242 - - - - Wall C-3 2 Both - - 1212 - 1.0 - 242 - - 3446 - Seg. 1 - Both 146.9 23.2 588 - 1.0 - 242 - 242 967 0.61 Open. 1 - Both - 170.1 1021 - - - 242 - 242 1451 0.70 Seg. 2 - Both 146.9 23.2 624 - 1.0 - 242 - 242 1028 0.61 Legend: 10 22 of 65 WoodWorks® Shearwalls 230371 - LATERAL ANALYSIS.wsw Aug. 22, 2023 13:07:03 W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir – Direction of seismic force along shearline. v - Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.4.3 Force-transfer walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier: Aspect ratio adjustment from SDPWS 4.3.3.4.1 Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "W" indicates that the wind design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. 11 23 of 65 ROOF FRAMING Member Name Results Current Solution Comments R1 Passed 1 piece(s) 4 x 8 DF No.2 R2 Passed 1 piece(s) 4 x 8 DF No.2 R3 Passed 1 piece(s) 4 x 8 DF No.2 R4 Passed 1 piece(s) 4 x 8 DF No.2 R5 Passed 1 piece(s) 6 x 8 DF No.2 UPPER FLOOR FRAMING Member Name Results Current Solution Comments U1 Passed 1 piece(s) 2 x 12 HF No.2 @ 16" OC U2 Passed 1 piece(s) 2 x 12 HF No.2 @ 16" OC U3 Passed 1 piece(s) 1 3/4" x 11 1/4" 2.0E Microllam® LVL U4 Passed 1 piece(s) 5 1/2" x 9" 24F-V4 DF Glulam U5 Passed 2 piece(s) 2 x 12 HF No.2 U6 Passed 3 piece(s) 2 x 12 HF No.2 U7 Passed 2 piece(s) 2 x 12 HF No.2 U8 Passed 2 piece(s) 2 x 12 HF No.2 U9 Passed 2 piece(s) 2 x 12 HF No.2 U10 Passed 1 piece(s) 4 x 8 DF No.2 U11 Passed 1 piece(s) 4 x 8 DF No.2 U12 Passed 1 piece(s) 4 x 8 DF No.2 U13 Passed 1 piece(s) 4 x 8 DF No.2 U14 Passed 1 piece(s) 4 x 8 DF No.2 U15 Passed 1 piece(s) 4 x 8 DF No.2 U16 Passed 1 piece(s) 4 x 8 DF No.2 U17 Passed 1 piece(s) 3 1/2" x 12" 24F-V4 DF Glulam MAIN FLOOR FRAMING Member Name Results Current Solution Comments M1 Passed 1 piece(s) 2 x 12 HF No.2 @ 16" OC M2 Passed 1 piece(s) 2 x 10 HF No.2 @ 16" OC M3 Passed 3 piece(s) 2 x 10 HF No.2 M4 Passed 1 piece(s) 4 x 10 DF No.2 M5 Passed 3 piece(s) 2 x 10 HF No.2 M6 Passed 2 piece(s) 1 3/4" x 11 1/4" 2.0E Microllam® LVL 230371 - BEAM CALCULATIONS JOB SUMMARY REPORT ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6 File Name: 230371 - BEAM CALCULATIONS Page 1 / 2924 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)412 @ 0 3281 (1.50")Passed (13%)--1.0 D + 1.0 S (All Spans) Shear (lbs)316 @ 8 3/4"3502 Passed (9%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)643 @ 3' 1 1/2"3438 Passed (19%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.014 @ 3' 1 1/2"0.208 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.025 @ 3' 1 1/2"0.313 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Factored Accessories 1 - Trimmer - HF 1.50"1.50"1.50"177 234 412 None 2 - Trimmer - HF 1.50"1.50"1.50"177 234 412 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Snow Vertical Loads Location Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 6' 3"3'16.8 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R1 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 2 / 2925 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1603 @ 0 3281 (1.50")Passed (49%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1111 @ 8 3/4"3502 Passed (32%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1903 @ 2' 4 1/2"3438 Passed (55%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.026 @ 2' 4 1/2"0.158 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.043 @ 2' 4 1/2"0.237 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Factored Accessories 1 - Trimmer - HF 1.50"1.50"1.50"653 950 1603 None 2 - Trimmer - HF 1.50"1.50"1.50"653 950 1603 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Snow Vertical Loads Location Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 4' 9"N/A 6.4 -- 1 - Uniform (PSF)0 to 4' 9"16'16.8 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R2 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 3 / 2926 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1771 @ 0 3281 (1.50")Passed (54%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1279 @ 8 3/4"3502 Passed (37%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2325 @ 2' 7 1/2"3438 Passed (68%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.038 @ 2' 7 1/2"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.065 @ 2' 7 1/2"0.262 Passed (L/971)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Factored Accessories 1 - Trimmer - HF 1.50"1.50"1.50"721 1050 1771 None 2 - Trimmer - HF 1.50"1.50"1.50"721 1050 1771 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Snow Vertical Loads Location Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 5' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 5' 3"16'16.8 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R3 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 4 / 2927 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)369 @ 0 3281 (1.50")Passed (11%)--1.0 D + 1.0 S (All Spans) Shear (lbs)242 @ 8 3/4"3502 Passed (7%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)392 @ 2' 1 1/2"3438 Passed (11%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.004 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.007 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Factored Accessories 1 - Trimmer - HF 1.50"1.50"1.50"156 212 369 None 2 - Trimmer - HF 1.50"1.50"1.50"156 212 369 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Snow Vertical Loads Location Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 4' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 4' 3"4'16.8 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R4 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 5 / 2928 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)658 @ 4"12251 (5.50")Passed (5%)--1.0 D + 1.0 S (All Spans) Shear (lbs)466 @ 1' 1"5376 Passed (9%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1011 @ 3' 8 1/2"3706 Passed (27%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.019 @ 3' 8 1/2"0.338 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.033 @ 3' 8 1/2"0.450 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Factored Accessories 1 - Stud wall - HF 5.50"5.50"1.50"288 371 658 Blocking 2 - Stud wall - HF 5.50"5.50"1.50"288 371 658 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 7' 5"N/A 10.4 -- 1 - Uniform (PSF)0 to 7' 5" (Top)4'16.8 25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF FRAMING, R5 1 piece(s) 6 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 6 / 2929 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)565 @ 4 1/2"2582 (4.25")Passed (22%)--1.0 D + 1.0 L (All Spans) Shear (lbs)479 @ 1' 4 3/4"1688 Passed (28%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2246 @ 8' 7"2577 Passed (87%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.377 @ 8' 7"0.410 Passed (L/523)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.471 @ 8' 7"0.821 Passed (L/418)--1.0 D + 1.0 L (All Spans) TJ-Pro™ Rating N/A N/A N/A --N/A System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. •No composite action between deck and joist was considered in analysis. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - HF 5.50"4.25"1.50"114 458 572 1 1/4" Rim Board 2 - Stud wall - HF 5.50"4.25"1.50"114 458 572 1 1/4" Rim Board Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 17' 2"16"10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U1 1 piece(s) 2 x 12 HF No.2 @ 16" OC ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 7 / 2930 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)598 @ 1' 11 3/4"3341 (5.50")Passed (18%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)285 @ 9 3/4"1941 Passed (15%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)-583 @ 1' 11 3/4"2371 Passed (25%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.007 @ 0 0.200 Passed (2L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in)0.017 @ 0 0.200 Passed (2L/999+)--1.0 D + 0.75 L + 0.75 S (Alt Spans) TJ-Pro™ Rating N/A N/A N/A --N/A System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Overhang deflection criteria: LL (0.2") and TL (0.2"). •A 15% increase in the moment capacity has been added to account for repetitive member usage. •A 20% decrease in the moment capacity has been added to account for lateral stability. •Applicable calculations are based on NDS. •No composite action between deck and joist was considered in analysis. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Factored Accessories 1 - Stud wall - HF 5.50"5.50"1.50"306 243 147 598 Blocking 2 - Hanger on 11 1/4" HF beam 5.50"Hanger¹1.50"-50 137 -47 87/-97 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LUS28 1.75"N/A 6-10dx1.5 3-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Snow Vertical Loads Location (Side)Spacing (0.90)(1.00)(1.15)Comments 1 - Uniform (PSF)0 to 6' 8"16"10.0 40.0 -FLOOR 2 - Point (lb)0 N/A 107 --WALL 3 - Point (lb)0 N/A 60 -100 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U2 1 piece(s) 2 x 12 HF No.2 @ 16" OC ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 8 / 2931 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1317 @ 2' 2 3/4"3898 (5.50")Passed (34%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)460 @ 1' 3/4"4302 Passed (11%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)-1076 @ 2' 2 3/4"7770 Passed (14%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.012 @ 0 0.200 Passed (2L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.025 @ 0 0.223 Passed (2L/999+)--1.0 D + 1.0 S (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Overhang deflection criteria: LL (0.2") and TL (2L/240). •A 16.3% decrease in the moment capacity has been added to account for lateral stability. •-208 lbs uplift at support located at 6' 5 1/2". Strapping or other restraint may be required. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Factored Accessories 1 - Beam - HF 5.50"5.50"1.86"697 263 563 1317 Blocking 2 - Hanger on 11 1/4" HF beam 5.50"Hanger¹1.50"-91 137/-7 -117 47/-208 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger IUS1.81/9.5 2.00"N/A 8-10dx1.5 2-10dx1.5 •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 5 1/2"N/A 5.7 ---- 1 - Uniform (PSF)0 to 6' 11" (Top)1' 4"10.0 40.0 -FLOOR 2 - Uniform (PLF)0 to 2' 3" (Top)N/A 80.0 --WALL 3 - Uniform (PSF)0 to 2' 3" (Top)8'16.8 -25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U3 1 piece(s) 1 3/4" x 11 1/4" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 9 / 2932 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) [Group] Member Reaction (lbs)1617 @ 4"9467 (4.25")Passed (17%)--1.0 D + 1.0 L (All Spans) [1] Shear (lbs)1410 @ 1' 2 1/2"8745 Passed (16%)1.00 1.0 D + 1.0 L (All Spans) [1] Pos Moment (Ft-lbs)6490 @ 8' 6"14850 Passed (44%)1.00 1.0 D + 1.0 L (All Spans) [1] Live Load Defl. (in)0.419 @ 8' 6 5/16"0.412 Passed (L/472)--1.0 D + 1.0 L (All Spans) [1] Total Load Defl. (in)0.529 @ 8' 6 13/16"0.825 Passed (L/374)--1.0 D + 1.0 L (All Spans) [1] System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 16' 6". •The effects of positive or negative camber have not been accounted for when calculating deflection. •The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. •Applicable calculations are based on NDS. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Factored Accessories 1 - Stud wall - HF 5.50"4.25"1.50"341 1294 -79 1635 1 1/4" Rim Board 2 - Stud wall - HF 5.50"4.25"1.50"373 1247 -38 1619 1 1/4" Rim Board Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)1 1/4" to 17' 3/4"N/A 12.0 ---- 1 - Uniform (PSF)0 to 17' 2" (Top)3' 6"10.0 40.0 -FLOOR 2 - Point (lb)5' 9" (Top)N/A -91 137/-7 -117 Linked from: U3, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U4 1 piece(s) 5 1/2" x 9" 24F-V4 DF Glulam ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 10 / 2933 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)496 @ 5 1/2"1823 (1.50")Passed (27%)--1.0 D + 1.0 L (All Spans) Shear (lbs)210 @ 1' 4 3/4"3375 Passed (6%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)403 @ 2' 1"4482 Passed (9%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.001 @ 2' 1"0.081 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.002 @ 2' 1"0.162 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Applicable calculations are based on NDS. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Hanger on 11 1/4" HF beam 5.50"Hanger¹1.50"271 361 632 See note ¹ 2 - Hanger on 11 1/4" HF beam 5.50"Hanger¹1.50"271 361 632 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger LUS28-2 2.00"N/A 6-10dx1.5 3-10d 2 - Face Mount Hanger LUS28-2 2.00"N/A 6-10dx1.5 3-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)5 1/2" to 3' 8 1/2"N/A 8.6 -- 1 - Uniform (PSF)0 to 4' 2" (Top)3'10.0 40.0 FLOOR 2 - Uniform (PLF)0 to 4' 2" (Top)N/A 80.0 -WALL 3 - Uniform (PSF)0 to 4' 2" (Top)1' 4"10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U5 2 piece(s) 2 x 12 HF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 11 / 2934 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)2742 @ 4"7746 (4.25")Passed (35%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1983 @ 1' 4 3/4"5063 Passed (39%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)5763 @ 4' 6"6724 Passed (86%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.108 @ 5' 3 5/8"0.262 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.151 @ 5' 3 3/4"0.525 Passed (L/837)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Applicable calculations are based on NDS. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - HF 5.50"4.25"1.50"704 2098 2802 1 1/4" Rim Board 2 - Stud wall - HF 5.50"4.25"1.50"392 999 1391 1 1/4" Rim Board Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/4" to 11' 3/4"N/A 12.8 -- 1 - Uniform (PSF)0 to 4' 6" (Top)9'10.0 40.0 FLOOR 2 - Uniform (PSF)0 to 11' 2" (Top)2' 6"10.0 40.0 FLOOR 3 - Point (lb)4' 6" (Top)N/A 271 361 Linked from: U5, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U6 3 piece(s) 2 x 12 HF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 12 / 2935 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1670 @ 2"2734 (2.25")Passed (61%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1168 @ 1' 2 3/4"3375 Passed (35%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2207 @ 3' 5 5/8"4482 Passed (49%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.033 @ 3' 7 7/8"0.177 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.044 @ 3' 7 11/16"0.354 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Applicable calculations are based on NDS. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - HF 3.50"2.25"1.50"492 1209 1701 1 1/4" Rim Board 2 - Stud wall - HF 5.50"4.25"1.50"297 972 1269 1 1/4" Rim Board Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/4" to 7' 5 3/4"N/A 8.6 -- 1 - Uniform (PSF)0 to 7' 7" (Top)6'10.0 40.0 FLOOR 2 - Point (lb)1' (Top)N/A 271 361 Linked from: U5, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U7 2 piece(s) 2 x 12 HF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 13 / 2936 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1255 @ 4' 5 1/2"1823 (1.50")Passed (69%)--1.0 D + 1.0 L (All Spans) Shear (lbs)685 @ 3' 6 1/4"3375 Passed (20%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1294 @ 2' 4 3/4"4482 Passed (29%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.007 @ 2' 4 3/4"0.103 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.009 @ 2' 4 3/4"0.206 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Applicable calculations are based on NDS. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - HF 5.50"4.25"1.50"307 1150 1457 1 1/4" Rim Board 2 - Hanger on 11 1/4" HF beam 3.00"Hanger¹1.50"295 1110 1405 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LUS210-2 2.00"N/A 8-10d 6-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/4" to 4' 5 1/2"N/A 8.6 -- 1 - Uniform (PSF)0 to 4' 8 1/2" (Top)12'10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U8 2 piece(s) 2 x 12 HF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 14 / 2937 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1806 @ 4"5164 (4.25")Passed (35%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1709 @ 1' 4 3/4"3375 Passed (51%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)3321 @ 5' 5 1/4"4482 Passed (74%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.205 @ 7' 1 11/16"0.483 Passed (L/850)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.276 @ 7' 2 1/16"0.725 Passed (L/631)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - HF 5.50"4.25"1.50"426 1387 1813 1 1/4" Rim Board 2 - Stud wall - HF 5.50"4.25"1.50"199 532 731 1 1/4" Rim Board Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/4" to 15' 3/4"N/A 8.6 -- 1 - Uniform (PSF)0 to 15' 2" (Top)1' 4"10.0 40.0 FLOOR 2 - Point (lb)2' (Top)N/A 295 1110 Linked from: U8, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U9 2 piece(s) 2 x 12 HF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 15 / 2938 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1148 @ 0 3281 (1.50")Passed (35%)--1.0 D + 1.0 L (All Spans) Shear (lbs)633 @ 8 3/4"3045 Passed (21%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)933 @ 1' 7 1/2"2989 Passed (31%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.008 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.010 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Trimmer - HF 1.50"1.50"1.50"238 910 1148 None 2 - Trimmer - HF 1.50"1.50"1.50"238 910 1148 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 6.4 -- 1 - Uniform (PSF)0 to 3' 3"14'10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U10 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 16 / 2939 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1491 @ 0 3281 (1.50")Passed (45%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1049 @ 8 3/4"3045 Passed (34%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1832 @ 2' 5 1/2"2989 Passed (61%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.035 @ 2' 5 1/2"0.164 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.045 @ 2' 5 1/2"0.246 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Trimmer - HF 1.50"1.50"1.50"311 1180 1491 None 2 - Trimmer - HF 1.50"1.50"1.50"311 1180 1491 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 4' 11"N/A 6.4 -- 1 - Uniform (PSF)0 to 4' 11"12'10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U11 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 17 / 2940 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1034 @ 0 3281 (1.50")Passed (32%)--1.0 D + 1.0 L (All Spans) Shear (lbs)679 @ 8 3/4"3045 Passed (22%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1099 @ 2' 1 1/2"2989 Passed (37%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.012 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.020 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Factored Accessories 1 - Trimmer - HF 1.50"1.50"1.50"439 595 159 1034 None 2 - Trimmer - HF 1.50"1.50"1.50"439 595 159 1034 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Snow Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 4' 3"N/A 6.4 ---- 1 - Uniform (PSF)0 to 4' 3"7'10.0 40.0 -FLOOR 2 - Uniform (PLF)0 to 4' 3"N/A 80.0 --WALL 3 - Uniform (PSF)0 to 4' 3"3'16.8 -25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U12 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 18 / 2941 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)791 @ 0 3281 (1.50")Passed (24%)--1.0 D + 1.0 L (All Spans) Shear (lbs)436 @ 8 3/4"3045 Passed (14%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)643 @ 1' 7 1/2"2989 Passed (21%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.004 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.007 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Factored Accessories 1 - Trimmer - HF 1.50"1.50"1.50"336 455 122 791 None 2 - Trimmer - HF 1.50"1.50"1.50"336 455 122 791 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Snow Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 6.4 ---- 1 - Uniform (PSF)0 to 3' 3"7'10.0 40.0 -FLOOR 2 - Uniform (PLF)0 to 3' 3"N/A 80.0 --WALL 3 - Uniform (PSF)0 to 3' 3"3'16.8 -25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U13 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 19 / 2942 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1521 @ 0 3281 (1.50")Passed (46%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1166 @ 8 3/4"3045 Passed (38%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2377 @ 3' 1 1/2"2989 Passed (80%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.054 @ 3' 1 1/2"0.208 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.094 @ 3' 1 1/2"0.313 Passed (L/798)--1.0 D + 1.0 L (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Factored Accessories 1 - Trimmer - HF 1.50"1.50"1.50"646 875 234 1521 None 2 - Trimmer - HF 1.50"1.50"1.50"646 875 234 1521 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Snow Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 6' 3"N/A 6.4 ---- 1 - Uniform (PSF)0 to 6' 3"7'10.0 40.0 -FLOOR 2 - Uniform (PLF)0 to 6' 3"N/A 80.0 --WALL 3 - Uniform (PSF)0 to 6' 3"3'16.8 -25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U14 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 20 / 2943 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)864 @ 0 3281 (1.50")Passed (26%)--1.0 D + 1.0 S (All Spans) Shear (lbs)304 @ 8 3/4"3502 Passed (9%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)486 @ 1' 1 1/2"3438 Passed (14%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.001 @ 1' 1 1/2"0.075 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.002 @ 1' 1 1/2"0.112 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Factored Accessories 1 - Trimmer - HF 1.50"1.50"1.50"414 60 450 864 None 2 - Trimmer - HF 1.50"1.50"1.50"414 60 450 864 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Snow Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 2' 3"N/A 6.4 ---- 1 - Uniform (PSF)0 to 2' 3"1' 4"10.0 40.0 -FLOOR 2 - Uniform (PLF)0 to 2' 3"N/A 80.0 --WALL 3 - Uniform (PSF)0 to 2' 3"16'16.8 -25.0 ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U15 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 21 / 2944 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)707 @ 0 3281 (1.50")Passed (22%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)390 @ 8 3/4"3502 Passed (11%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Moment (Ft-lbs)574 @ 1' 7 1/2"3438 Passed (17%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.003 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.006 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Factored Accessories 1 - Trimmer - HF 1.50"1.50"1.50"372 163 284 707 None 2 - Trimmer - HF 1.50"1.50"1.50"372 163 284 707 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Snow Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 3"N/A 6.4 ---- 1 - Uniform (PSF)0 to 3' 3"2' 6"10.0 40.0 -FLOOR 2 - Uniform (PLF)0 to 3' 3"N/A 80.0 --WALL 3 - Uniform (PSF)0 to 3' 3"6'16.8 -25.0 ROOF 4 - Uniform (PSF)0 to 3' 3"1'16.8 -25.0 LOWER ROOF Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U16 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 22 / 2945 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3691 @ 1 1/2"6825 (3.00")Passed (54%)--1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs)3187 @ 1' 3"8533 Passed (37%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Pos Moment (Ft-lbs)10639 @ 5' 6 13/16"19320 Passed (55%)1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Live Load Defl. (in)0.152 @ 6' 1 7/16"0.408 Passed (L/970)--1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in)0.319 @ 6' 1 3/8"0.613 Passed (L/461)--1.0 D + 0.75 L + 0.75 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 12' 3". •The effects of positive or negative camber have not been accounted for when calculating deflection. •The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Factored Accessories 1 - Trimmer - HF 3.00"3.00"1.62"1949 1100 1222 3691 None 2 - Trimmer - HF 3.00"3.00"1.50"1666 1173 849 3183 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Snow Vertical Loads Location Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 12' 6"N/A 10.2 ---- 1 - Uniform (PSF)0 to 3' 3"2' 6"10.0 40.0 -FLOOR 2 - Uniform (PLF)0 to 3' 3"N/A 80.0 --WALL 3 - Uniform (PSF)0 to 3' 3"6'16.8 -25.0 ROOF 4 - Uniform (PLF)3' 3" to 12' 6"N/A 229.5 182.3 110.3 Linked from: U2, Support 1 5 - Point (lb)3' 3"N/A 697 263 563 Linked from: U3, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED UPPER FLOOR FRAMING, U17 1 piece(s) 3 1/2" x 12" 24F-V4 DF Glulam ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 23 / 2946 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)403 @ 12' 5 1/2"911 (1.50")Passed (44%)--1.0 D + 1.0 L (All Spans) Shear (lbs)340 @ 11' 6 1/4"1688 Passed (20%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1217 @ 6' 5"2577 Passed (47%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.111 @ 6' 5"0.302 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.138 @ 6' 5"0.604 Passed (L/999+)--1.0 D + 1.0 L (All Spans) TJ-Pro™ Rating N/A N/A N/A --N/A System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. •No composite action between deck and joist was considered in analysis. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - HF 5.50"4.25"1.50"86 342 428 1 1/4" Rim Board 2 - Hanger on 11 1/4" HF beam 5.50"Hanger¹1.50"87 347 433 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LUS28 1.75"N/A 6-10dx1.5 3-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 12' 11"16"10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED MAIN FLOOR FRAMING, M1 1 piece(s) 2 x 12 HF No.2 @ 16" OC ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 24 / 2947 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)525 @ 10' 9 1/2"2582 (4.25")Passed (20%)--1.0 D + 1.0 L (All Spans) Shear (lbs)450 @ 9' 11 1/4"1388 Passed (32%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1281 @ 6' 6 7/8"1917 Passed (67%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.110 @ 5' 7"0.260 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.193 @ 5' 8 3/4"0.521 Passed (L/648)--1.0 D + 1.0 L (All Spans) TJ-Pro™ Rating N/A N/A N/A --N/A System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. •No composite action between deck and joist was considered in analysis. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - HF 5.50"4.25"1.50"140 298 438 1 1/4" Rim Board 2 - Stud wall - HF 5.50"4.25"1.50"234 298 532 1 1/4" Rim Board Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 11' 2"16"10.0 40.0 FLOOR 2 - Point (lb)7' 9"N/A 120 -WALL 3 - Point (lb)7' 9"N/A 106 -WALL Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED MAIN FLOOR FRAMING, M2 1 piece(s) 2 x 10 HF No.2 @ 16" OC ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 25 / 2948 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1570 @ 4"7746 (4.25")Passed (20%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1484 @ 1' 2 3/4"4163 Passed (36%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)4855 @ 3' 9"5000 Passed (97%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.148 @ 5' 2 11/16"0.262 Passed (L/851)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.210 @ 5' 2 3/4"0.525 Passed (L/600)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Applicable calculations are based on NDS. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - HF 5.50"4.25"1.50"464 1113 1577 1 1/4" Rim Board 2 - Stud wall - HF 5.50"4.25"1.50"292 691 983 1 1/4" Rim Board Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/4" to 11' 3/4"N/A 10.6 -- 1 - Uniform (PSF)0 to 11' 2" (Top)1' 4"10.0 40.0 FLOOR 2 - Point (lb)3' 9" (Top)N/A 492 1209 Linked from: U7, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED MAIN FLOOR FRAMING, M3 3 piece(s) 2 x 10 HF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 26 / 2949 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1470 @ 2"4961 (3.50")Passed (30%)--1.0 D + 1.0 L (All Spans) Shear (lbs)983 @ 1' 3/4"3885 Passed (25%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)2120 @ 3' 2 1/2"4492 Passed (47%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.030 @ 3' 2 1/2"0.203 Passed (L/999+)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.038 @ 3' 2 1/2"0.304 Passed (L/999+)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - HF 3.50"3.50"1.50"315 1155 1470 Blocking 2 - Stud wall - HF 3.50"3.50"1.50"315 1155 1470 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)0 to 6' 5"N/A 8.2 -- 1 - Uniform (PSF)0 to 6' 5" (Top)9'10.0 40.0 FLOOR Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED MAIN FLOOR FRAMING, M4 1 piece(s) 4 x 10 DF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 27 / 2950 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1570 @ 4"7746 (4.25")Passed (20%)--1.0 D + 1.0 L (All Spans) Shear (lbs)1484 @ 1' 2 3/4"4163 Passed (36%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)4855 @ 3' 9"5000 Passed (97%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.148 @ 5' 2 11/16"0.262 Passed (L/851)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.210 @ 5' 2 3/4"0.525 Passed (L/600)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Applicable calculations are based on NDS. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - HF 5.50"4.25"1.50"464 1113 1577 1 1/4" Rim Board 2 - Stud wall - HF 5.50"4.25"1.50"292 691 983 1 1/4" Rim Board Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/4" to 11' 3/4"N/A 10.6 -- 1 - Uniform (PSF)0 to 11' 2" (Top)1' 4"10.0 40.0 FLOOR 2 - Point (lb)3' 9" (Top)N/A 492 1209 Linked from: U7, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED MAIN FLOOR FRAMING, M5 3 piece(s) 2 x 10 HF No.2 ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 28 / 2951 of 65 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)4567 @ 10' 10"6024 (4.25")Passed (76%)--1.0 D + 1.0 L (All Spans) Shear (lbs)3574 @ 9' 9 1/4"7481 Passed (48%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)12051 @ 5' 4 7/8"16137 Passed (75%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.229 @ 5' 5 3/4"0.262 Passed (L/549)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.306 @ 5' 5 11/16"0.525 Passed (L/412)--1.0 D + 1.0 L (All Spans) System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Factored Accessories 1 - Stud wall - HF 5.50"4.25"2.38"857 2520 3377 1 1/4" Rim Board 2 - Stud wall - HF 5.50"4.25"3.22"1183 3463 4645 1 1/4" Rim Board Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)End Bearing Points Dead Floor Live Vertical Loads Location (Side)Tributary Width (0.90)(1.00)Comments 0 - Self Weight (PLF)1 1/4" to 11' 3/4"N/A 11.5 -- 1 - Uniform (PSF)0 to 11' 2" (Top)1' 4"10.0 40.0 FLOOR 2 - Uniform (PLF)3' 9" to 5' 6" (Top)N/A 90.0 -WALL 3 - Uniform (PLF)9' 6" to 11' 2" (Top)N/A 90.0 -WALL 4 - Uniform (PSF)3' 9" to 5' 6" (Top)12'10.0 40.0 FLOOR 5 - Uniform (PSF)9' 6" to 11' 2" (Top)12'10.0 40.0 FLOOR 6 - Point (lb)3' 9" (Top)N/A 426 1387 Linked from: U9, Support 1 7 - Point (lb)5' 6" (Top)N/A 311 1180 Linked from: U11, Support 1 8 - Point (lb)9' 6" (Top)N/A 311 1180 Linked from: U11, Support 2 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED MAIN FLOOR FRAMING, M6 2 piece(s) 1 3/4" x 11 1/4" 2.0E Microllam® LVL ForteWEB Software Operator Job Notes 8/22/2023 8:20:56 PM UTCAlec Hodge Hodge Engineering (253) 857-7055 alechodge@live.com ForteWEB v3.6, Engine: V8.3.0.43, Data: V8.1.4.1 File Name: 230371 - BEAM CALCULATIONS Page 29 / 2952 of 65 53 of 65 General Footing HODGE ENGINEERING INCLic. # : KW-06007122 DESCRIPTION:24" footing - 1500 psf soil Hodge Engineering, Inc 3733 Rosedale St. Suite 200 Gig Harbor, WA. 98335 253-857-7055 Software copyright ENERCALC, INC. 1983-2019, Build:12.19.11.30 . File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2018 Footing Pad Calcs.ec6 . Code References Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : IBC 2018 General Information Material Properties Soil Design Values 1.50 Analysis Settings 250.0ksi No ksfAllowable Soil Bearing = = 2.50 60.0 3,122.0 145.0 =0.30 Flexure =0.90 Shear = Valuesj 0.00180 Soil Passive Resistance (for Sliding) 1.0 = Increases based on footing plan dimension Add Pedestal Wt for Soil Pressure No: Use Pedestal wt for stability, mom & shear No: Allowable pressure increase per foot of depth =ksfwhen max. length or width is greater than =ft : = Add Ftg Wt for Soil Pressure Yes Yes:Use ftg wt for stability, moments & shears when footing base is below ft pcf Increase Bearing By Footing Weight =pcf Min. Overturning Safety Factor = : 1 Increases based on footing Depth0.750 = Soil/Concrete Friction Coeff. Ec : Concrete Elastic Modulus = =Footing base depth below soil surface ft =Allow press. increase per foot of depth ksf = : 11.0Min. Sliding Safety Factor = = Concrete Density = Min Allow % Temp Reinf. ksif'c : Concrete 28 day strength fy : Rebar Yield ksi Min Steel % Bending Reinf. # Dimensions Width parallel to X-X Axis 2.0 ft Length parallel to Z-Z Axis = 2.0 ft =Pedestal dimensions... px : parallel to X-X Axis in pz : parallel to Z-Z Axis in Height == in Footing Thickness = 8.0 in= Rebar Centerline to Edge of Concrete...=inat Bottom of footing 3.0 Reinforcing # Bars parallel to X-X Axis Reinforcing Bar Size = 4Number of Bars = 2.0 Bars parallel to Z-Z Axis Reinforcing Bar Size =4Number of Bars =2.0 Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation n/a # Bars required within zone n/a # Bars required on each side of zone n/a Applied Loads 2.50 3.0 D Lr ksf L S P : Column Load OB : Overburden = k W E M-zz V-x = =k V-z k M-xx = k-ft= k-ft H = 54 of 65 General Footing HODGE ENGINEERING INCLic. # : KW-06007122 DESCRIPTION:24" footing - 1500 psf soil Hodge Engineering, Inc 3733 Rosedale St. Suite 200 Gig Harbor, WA. 98335 253-857-7055 Software copyright ENERCALC, INC. 1983-2019, Build:12.19.11.30 . File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2018 Footing Pad Calcs.ec6 . PASS n/a Sliding - X-X 0.0k 0.0k No Sliding PASS n/a Sliding - Z-Z 0.0k 0.0k No Sliding DESIGN SUMMARY Design OK Governing Load CombinationMin. Ratio Item Applied Capacity PASS 0.9813 Soil Bearing 1.472ksf 1.50ksf +D+S PASS n/a Overturning - X-X 0.0k-ft 0.0k-ft No Overturning PASS n/a Overturning - Z-Z 0.0k-ft 0.0k-ft No Overturning PASS n/a Uplift 0.0k 0.0k No Uplift PASS 0.2505 Z Flexure (+X)1.074k-ft/ft 4.288k-ft/ft +1.20D+1.60S PASS 0.2505 Z Flexure (-X)1.074k-ft/ft 4.288k-ft/ft +1.20D+1.60S PASS 0.2505 X Flexure (+Z)1.074k-ft/ft 4.288k-ft/ft +1.20D+1.60S PASS 0.2505 X Flexure (-Z)1.074k-ft/ft 4.288k-ft/ft +1.20D+1.60S PASS 0.2769 1-way Shear (+X)20.770psi 75.0psi +1.20D+1.60S PASS 0.2769 1-way Shear (-X)20.770psi 75.0psi +1.20D+1.60S PASS 0.2769 1-way Shear (+Z)20.770psi 75.0psi +1.20D+1.60S PASS 0.2769 1-way Shear (-Z)20.770psi 75.0psi +1.20D+1.60S PASS 0.5289 2-way Punching 79.334psi 150.0psi +1.20D+1.60S Detailed Results Rotation Axis &ZeccXecc Actual Soil Bearing Stress @ Location Actual / Allow Soil Bearing (in)Gross Allowable Bottom Left Top Left Top Right Bottom Right RatioLoad Combination... , D Only 0.000 , 0.0 deg CCW 1.50 0.72170.7217 0.7217 0.7217 0.4810.00.0 , +D+S 0.000 , 0.0 deg CCW 1.50 1.4721.472 1.472 1.472 0.9810.00.0 , +D+0.750S 0.000 , 0.0 deg CCW 1.50 1.2841.284 1.284 1.284 0.8560.00.0 , +0.60D 0.000 , 0.0 deg CCW 1.50 0.43300.4330 0.4330 0.4330 0.2890.00.0 Rotation Axis & Overturning Stability Load Combination...StatusOverturning Moment Resisting Moment Stability Ratio Footing Has NO Overturning Force Application Axis Sliding Stability All units k Load Combination...StatusSliding Force Resisting Force Stability Ratio Footing Has NO Sliding Flexure Axis & Load Combination in^2 in^2 in^2 k-ft As Req'd Footing Flexure Tension k-ft Actual As StatusMu Side Surface Gvrn. As Phi*Mn X-X, +1.40D 0.5254 +Z Bottom 0.1728 Min Temp %0.20 4.288 OK X-X, +1.40D 0.5254 -Z Bottom 0.1728 Min Temp %0.20 4.288 OK X-X, +1.20D 0.4503 +Z Bottom 0.1728 Min Temp %0.20 4.288 OK X-X, +1.20D 0.4503 -Z Bottom 0.1728 Min Temp %0.20 4.288 OK X-X, +1.20D+0.50S 0.6453 +Z Bottom 0.1728 Min Temp %0.20 4.288 OK X-X, +1.20D+0.50S 0.6453 -Z Bottom 0.1728 Min Temp %0.20 4.288 OK X-X, +1.20D+1.60S 1.074 +Z Bottom 0.1728 Min Temp %0.20 4.288 OK X-X, +1.20D+1.60S 1.074 -Z Bottom 0.1728 Min Temp %0.20 4.288 OK X-X, +1.20D+0.70S 0.7233 +Z Bottom 0.1728 Min Temp %0.20 4.288 OK X-X, +1.20D+0.70S 0.7233 -Z Bottom 0.1728 Min Temp %0.20 4.288 OK X-X, +0.90D 0.3377 +Z Bottom 0.1728 Min Temp %0.20 4.288 OK X-X, +0.90D 0.3377 -Z Bottom 0.1728 Min Temp %0.20 4.288 OK Z-Z, +1.40D 0.5254 -X Bottom 0.1728 Min Temp %0.20 4.288 OK Z-Z, +1.40D 0.5254 +X Bottom 0.1728 Min Temp %0.20 4.288 OK Z-Z, +1.20D 0.4503 -X Bottom 0.1728 Min Temp %0.20 4.288 OK Z-Z, +1.20D 0.4503 +X Bottom 0.1728 Min Temp %0.20 4.288 OK 55 of 65 Concrete Beam HODGE ENGINEERING INCLic. # : KW-06007122 DESCRIPTION:12" footing with 6" stem wall 1500 psf soil, 2500 psi concrete Hodge Engineering, Inc 3733 Rosedale St. Suite 200 Gig Harbor, WA. 98335 253-857-7055 Software copyright ENERCALC, INC. 1983-2019, Build:12.19.11.30 . File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2018 Footing Pad Calcs.ec6 . CODE REFERENCES Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2018 Material Properties 2.50 7.50 145.0 Elastic Modulus 3,122.0 ksi 1 60.0 29,000.0 40.0 29,000.0 3= =0.90 0.750 f'c ksi fy - Main Rebar ksi Density 1/2 = fr = f'c *375.0 pcf E - Main Rebar ksi psi =1.0lLtWt Factor Fy - Stirrups ksi == = E - Stirrups ksi b 0.850 == = Shear : Stirrup Bar Size # Number of Resisting Legs Per Stirrup Phi Values Flexure : y f .Cross Section & Reinforcing Details Inverted Tee Section, Stem Width = 6.0 in, Total Height = 18.0 in, Top Flange Width = 12.0 in, Flange Thickness = 6.0 in Span #1 Reinforcing.... 2-#4 at 3.0 in from Bottom, from 0.0 to 5.0 ft in this span 1-#4 at 3.0 in from Top, from 0.0 to 5.0 ft in this span . Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load : D = 0.0150, S = 0.030 ksf, Tributary Width = 15.0 ft, (Roof) Uniform Load : D = 0.010, L = 0.040 ksf, Tributary Width = 7.0 ft, (Floor) Point Load : D = 3.0, S = 7.0 k @ 2.50 ft .Design OKDESIGN SUMMARY Maximum Bending Stress Ratio =0.892 : 1 Span # where maximum occurs Span # 1 Location of maximum on span 2.505 ft Mn * Phi : Allowable 25.551 k-ft Typical SectionSection used for this span Mu : Applied 22.804 k-ft Maximum Deflection 0 <360.0 9596 Ratio =0 <180.0 Max Downward Transient Deflection 0.003 in 19795Ratio =>=360.0 Max Upward Transient Deflection 0.000 in Ratio = Max Downward Total Deflection 0.006 in Ratio =>=180.0Max Upward Total Deflection 0.000 in . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Overall MAXimum 7.225 7.225 Overall MINimum 0.700 0.700 D Only 2.600 2.600 +D+L 3.300 3.300 +D+S 7.225 7.225 +D+0.750L 3.125 3.125 +D+0.750L+0.750S 6.594 6.594 +0.60D 1.560 1.560 L Only 0.700 0.700 S Only 4.625 4.625 . 56 of 65 Concrete Beam HODGE ENGINEERING INCLic. # : KW-06007122 DESCRIPTION:12" footing with 6" stem wall 1500 psf soil, 2500 psi concrete Hodge Engineering, Inc 3733 Rosedale St. Suite 200 Gig Harbor, WA. 98335 253-857-7055 Software copyright ENERCALC, INC. 1983-2019, Build:12.19.11.30 . File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2018 Footing Pad Calcs.ec6 . Span # Bending Stress Results ( k-ft )Location (ft)Load Combination Mu : Max Stress RatioSegmentPhi*Mnxalong Beam +1.20D+0.50L+0.50S Span # 1 1 5.000 11.65 25.55 0.46 +1.20D+0.50L+0.70S Span # 1 1 5.000 13.68 25.55 0.54 +0.90D Span # 1 1 5.000 4.61 25.55 0.18 . Location in Span (ft)Load CombinationMax. "-" Defl (in) Location in Span (ft)Load Combination Span Max. "+" Defl (in) Overall Maximum Deflections +D+S 1 0.0063 2.500 0.0000 0.000 57 of 65 Concrete Beam HODGE ENGINEERING INCLic. # : KW-06007122 Hodge Engineering, Inc 3733 Rosedale St. Suite 200 Gig Harbor, WA. 98335 253-857-7055 Software copyright ENERCALC, INC. 1983-2019, Build:12.19.11.30 . File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2018 Footing Pad Calcs.ec6 . DESCRIPTION: 15" footing with 8" stem wall 1500 psf soil, 2500 psi concrete CODE REFERENCES Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2018 Material Properties 2.50 7.50 145.0 Elastic Modulus 3,122.0 ksi 1 60.0 29,000.0 40.0 29,000.0 3= =0.90 0.750 f'c ksi fy - Main Rebar ksi Density 1/2 = fr = f'c *375.0 pcf E - Main Rebar ksi psi =1.0lLtWt Factor Fy - Stirrups ksi == = E - Stirrups ksi b 0.850 == = Shear : Stirrup Bar Size # Number of Resisting Legs Per Stirrup Phi Values Flexure : y f .Cross Section & Reinforcing Details Inverted Tee Section, Stem Width = 8.0 in, Total Height = 18.0 in, Top Flange Width = 15.0 in, Flange Thickness = 6.0 in Span #1 Reinforcing.... 2-#4 at 3.0 in from Bottom, from 0.0 to 5.0 ft in this span 1-#4 at 3.0 in from Top, from 0.0 to 5.0 ft in this span . Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load : D = 0.0150, S = 0.030 ksf, Tributary Width = 15.0 ft, (Roof) Uniform Load : D = 0.010, L = 0.040 ksf, Tributary Width = 7.0 ft, (Floor) Point Load : D = 3.0, S = 7.0 k @ 2.50 ft, (Point Load) .Design OKDESIGN SUMMARY Maximum Bending Stress Ratio =0.868 : 1 Span # where maximum occurs Span # 1 Location of maximum on span 2.495 ft Mn * Phi : Allowable 26.452 k-ft Typical SectionSection used for this span Mu : Applied 22.962 k-ft Maximum Deflection 0 <360.0 16719 Ratio =0 <180.0 Max Downward Transient Deflection 0.002 in 25683Ratio =>=360.0 Max Upward Transient Deflection 0.000 in Ratio = Max Downward Total Deflection 0.004 in Ratio =>=180.0Max Upward Total Deflection 0.000 in . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Overall MAXimum 7.331 7.331 Overall MINimum 0.700 0.700 D Only 2.706 2.706 +D+L 3.406 3.406 +D+S 7.331 7.331 +D+0.750L 3.231 3.231 +D+0.750L+0.750S 6.699 6.699 +0.60D 1.623 1.623 L Only 0.700 0.700 S Only 4.625 4.625 . 58 of 65 Concrete Beam HODGE ENGINEERING INCLic. # : KW-06007122 DESCRIPTION: 15" footing with 8" stem wall 1500 psf soil, 2500 psi concrete Hodge Engineering, Inc 3733 Rosedale St. Suite 200 Gig Harbor, WA. 98335 253-857-7055 Software copyright ENERCALC, INC. 1983-2019, Build:12.19.11.30 . File = C:\Users\JOHNHO~1\DOCUME~1\ENERCA~1\2018 Footing Pad Calcs.ec6 . Span # Bending Stress Results ( k-ft )Location (ft)Load Combination Mu : Max Stress RatioSegmentPhi*Mnxalong Beam +1.20D+0.50L+0.50S Span # 1 1 5.000 11.81 26.45 0.45 +1.20D+0.50L+0.70S Span # 1 1 5.000 13.84 26.45 0.52 +0.90D Span # 1 1 5.000 4.73 26.45 0.18 . Location in Span (ft)Load CombinationMax. "-" Defl (in) Location in Span (ft)Load Combination Span Max. "+" Defl (in) Overall Maximum Deflections +D+S 1 0.0036 2.500 0.0000 0.000 59 of 65 Hodge Engineering, Inc. 3733 Rosedale St. Ste. 200 Gig Harbor, WA. 98335 Title :6' Unrestrained 40 psf Surcharge Dsgnr:JEH Page : 1 Description.... 6' Unrestrained wall This Wall in File: C:\Users\johnhodge\Documents\RetainPro 10 Project Files\unrestrained walls 2.RPX RetainPro (c) 1987-2019, Build 11.20.03.31 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16License : KW-06053958License To : HODGE ENGINEERING Project Name/Number : unrestrained 6.00 0.50 0.00 12.00 1,500.0 35.0 0.0 300.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 110.00= pcf = Soil Density, Heel = Passive Pressure = psf/ft Allow Soil Bearing = psf Soil Density, Toe 110.00pcf Footing||Soil Friction =0.350 Soil height to ignore for passive pressure = 0.00in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 40.0 Lateral Load = 0.0#/ft 0.0 100.0 200.0 0.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe psf Footing Width =0.00ft...Height to Top =0.00ft Eccentricity =0.00in...Height to Bottom = 0.00ft Used To Resist Sliding & Overturning Used for Sliding & Overturning = 0.0ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability Ratios Overturning =2.07OK Sliding =1.55OK Total Bearing Load =2,391lbs ...resultant ecc. =6.69in Soil Pressure @ Toe =1,488psf OK Soil Pressure @ Heel =0psf OK Allowable =1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe =2,083psf ACI Factored @ Heel =0psf Footing Shear @ Toe =19.0psi OK Footing Shear @ Heel =9.2psi OK Allowable =75.0psi Sliding Calcs Lateral Sliding Force =883.3lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 766.8 600.0 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction 3rd 2nd Stem OKStem OK Stem OK Bottom Shear.....Actual Design Height Above Ftg =3.50ft 1.00 0.00 Wall Material Above "Ht" =Concrete Concrete Concrete Thickness =8.00 8.00 8.00 Rebar Size =###4 4 4 Rebar Spacing = 12.00 12.00 12.00 Rebar Placed at =Center Center Center Design Data fb/FB + fa/Fa =0.061 0.419 0.703 Total Force @ Section =l bs Moment....Actual =ft-# Moment.....Allowable =3,387.6 3,387.6 3,387.6ft-# =p si Shear.....Allowable =75.0 75.0psi 75.0 Wall Weight = 100.0 100.0psf 100.0 Rebar Depth 'd'= 4.00in 4.00 4.00 Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Data f'c =2,500.0 2,500.0psi 2,500.0 Fy =60,000.0 60,000.0 Masonry Design Method ASD= Load Factors Building Code IBC 2018,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi 60,000.0 Service Level = 225.9 801.8lbs 1,130.2Strength Level Service Level Strength Level = 209.5 1,421.2 2,382.5ft-# Service Level Strength Level = 4.7 16.7 23.5psi Design Method = LRFD LRFD LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Anet (Masonry)=in2 60 of 65 Hodge Engineering, Inc. 3733 Rosedale St. Ste. 200 Gig Harbor, WA. 98335 Title :6' Unrestrained 40 psf Surcharge Dsgnr:JEH Page : 2 Description.... 6' Unrestrained wall This Wall in File: C:\Users\johnhodge\Documents\RetainPro 10 Project Files\unrestrained walls 2.RPX RetainPro (c) 1987-2019, Build 11.20.03.31 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16License : KW-06053958License To : HODGE ENGINEERING Project Name/Number : unrestrained Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.0126 in2/ft (4/3) * As :0.0169 in2/ft Min Stem T&S Reinf Area 0.576 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.2 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.0858 in2/ft (4/3) * As :0.1144 in2/ft Min Stem T&S Reinf Area 0.480 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.2 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.1438 in2/ft (4/3) * As :0.1918 in2/ft Min Stem T&S Reinf Area 0.192 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.16 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.2 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in 1.30 1.96 9.00 Footing Torsion, Tu ==ft-lbs0 .00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 = 2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key Depth Key Width =in =in = 8.00 3.00 1.30ft Footing Thickness =in 3.26= Cover @ Top =2.00 in@ Btm.=3.00in Total Footing Width =150.00pcfFooting Concrete Density Fy=60,000psi Footing Design Results Key: = phiMn = phi'5'lambda'sqrt(fc)'Sm Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 12.34 in, #5@ 19.13 in, #6@ 27.16 in, #7@ 37.03 in, #8@ 48.76 in, #9@ 6 phiMn = phi'5'lambda'sqrt(fc)'Sm =# 4 @ 13.89 in = = = = = 2,083 18,171 2,691 1,290 19.05 75.00 Heel: 0 211 831 620 9.24 40.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =None Spec'd Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 4 @ 12.00 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 0.63 0.19 #4@ 12.35 in #5@ 19.14 in #6@ 27.16 in in2 in2 /ft If two layers of horizontal bars: #4@ 24.69 in #5@ 38.27 in #6@ 54.32 in supplemental design for footing torsion. 61 of 65 Hodge Engineering, Inc. 3733 Rosedale St. Ste. 200 Gig Harbor, WA. 98335 Title :8' Unrestrained 40 psf Surcharge Dsgnr:JEH Page : 1 Description.... 8' Unrestrained wall 40 psf surcharge This Wall in File: C:\Users\johnhodge\Documents\RetainPro 10 Project Files\unrestrained walls 2.RPX RetainPro (c) 1987-2019, Build 11.20.03.31 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16License : KW-06053958License To : HODGE ENGINEERING Project Name/Number : unrestrained 8.00 0.50 0.00 12.00 1,515.0 35.0 0.0 300.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 110.00= pcf = Soil Density, Heel = Passive Pressure = psf/ft Allow Soil Bearing = psf Soil Density, Toe 110.00pcf Footing||Soil Friction =0.350 Soil height to ignore for passive pressure = 0.00in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 40.0 Lateral Load = 0.0#/ft 0.0 100.0 200.0 0.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe psf Footing Width =0.00ft...Height to Top =0.00ft Eccentricity =0.00in...Height to Bottom = 0.00ft Used To Resist Sliding & Overturning Used for Sliding & Overturning = 0.0ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability Ratios Overturning =2.38OK Sliding =1.53OK Total Bearing Load =4,030lbs ...resultant ecc. =7.50in Soil Pressure @ Toe =1,514psf OK Soil Pressure @ Heel =179psf OK Allowable =1,515 psf Soil Pressure Less Than Allowable ACI Factored @ Toe =2,120psf ACI Factored @ Heel =251psf Footing Shear @ Toe =19.7psi OK Footing Shear @ Heel =11.6psi OK Allowable =75.0psi Sliding Calcs Lateral Sliding Force =1,532.0lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 1,340.3 1,001.0 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction 3rd 2nd Stem OKStem OK Stem OK Bottom Shear.....Actual Design Height Above Ftg =3.50ft 1.00 0.00 Wall Material Above "Ht" =Concrete Concrete Concrete Thickness =8.00 8.00 8.00 Rebar Size =###5 5 5 Rebar Spacing = 12.00 12.00 10.75 Rebar Placed at =Center Center Center Design Data fb/FB + fa/Fa =0.208 0.729 0.970 Total Force @ Section =l bs Moment....Actual =ft-# Moment.....Allowable =5,069.7 5,069.7 5,593.0ft-# =p si Shear.....Allowable =75.0 75.0psi 75.0 Wall Weight = 100.0 100.0psf 100.0 Rebar Depth 'd'= 4.00in 4.00 4.00 Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Data f'c =2,500.0 2,500.0psi 2,500.0 Fy =60,000.0 60,000.0 Masonry Design Method ASD= Load Factors Building Code IBC 2018,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi 60,000.0 Service Level = 658.6 1,514.5lbs 1,954.9Strength Level Service Level Strength Level = 1,056.7 3,700.2 5,430.3ft-# Service Level Strength Level = 13.7 31.6 40.7psi Design Method = LRFD LRFD LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Anet (Masonry)=in2 62 of 65 Hodge Engineering, Inc. 3733 Rosedale St. Ste. 200 Gig Harbor, WA. 98335 Title :8' Unrestrained 40 psf Surcharge Dsgnr:JEH Page : 2 Description.... 8' Unrestrained wall 40 psf surcharge This Wall in File: C:\Users\johnhodge\Documents\RetainPro 10 Project Files\unrestrained walls 2.RPX RetainPro (c) 1987-2019, Build 11.20.03.31 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16License : KW-06053958License To : HODGE ENGINEERING Project Name/Number : unrestrained Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.0638 in2/ft (4/3) * As :0.0851 in2/ft Min Stem T&S Reinf Area 0.960 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.31 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.2234 in2/ft (4/3) * As :0.2978 in2/ft Min Stem T&S Reinf Area 0.480 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.2234 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.31 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.3278 in2/ft (4/3) * As :0.4371 in2/ft Min Stem T&S Reinf Area 0.192 in2 200bd/fy : 200(12)(4)/60000 :0.16 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.3278 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.346 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.5419 in2/ft #6@ 27.50 in #6@ 55.00 in 2.05 2.71 12.00 Footing Torsion, Tu ==ft-lbs0 .00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 = 2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key Depth Key Width =in =in = 8.00 7.00 2.05ft Footing Thickness =in 4.76= Cover @ Top =2.00 in@ Btm.=3.00in Total Footing Width =150.00pcfFooting Concrete Density Fy=60,000psi Footing Design Results Key: = #4@ 13.88 in, #5@ 18 in, #6@ 18 in, #7@ 18 in, #8@ 18 i Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46 #4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46 =# 4 @ 13.89 in = = = = = 2,120 46,526 7,837 3,224 19.69 75.00 Heel: 251 1,086 2,721 1,635 11.62 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 4 @ 18.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 4 @ 9.26 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 1.23 0.26 #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in in2 in2 /ft If two layers of horizontal bars: #4@ 18.52 in #5@ 28.70 in #6@ 40.74 in supplemental design for footing torsion. 63 of 65 Hodge Engineering, Inc. 3733 Rosedale St. Ste. 200 Gig Harbor, WA. 98335 Title :10' Unrestrained 40 psf Surcharge Page : 1 Dsgnr:JEH Date: 11 JUN 2021 Description.... 10' Unrestrained wall with 40 psf surcharge This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2019, Build 11.20.03.31 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16License : KW-06053958License To : HODGE ENGINEERING Project Name/Number : unrestrained 10.00 0.50 0.00 12.00 1,500.0 35.0 0.0 300.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall Height of Soil over Toe in Water height over heel =ft = = 110.00= pcf = Soil Density, Heel = Passive Pressure = psf/ft Allow Soil Bearing = psf Soil Density, Toe 110.00pcf Footing||Soil Friction =0.350 Soil height to ignore for passive pressure = 0.00in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load Load Type 40.0 Lateral Load = 0.0#/ft 0.0 0.0 0.0 0.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00ft Wind on Exposed Stem psf0.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0lbs Axial Dead Load (Service Level) =lbs Footing Type Line Load Surcharge Over Toe psf Footing Width =0.00ft...Height to Top =0.00ft Eccentricity =0.00in...Height to Bottom = 0.00ft Used To Resist Sliding & Overturning Used for Sliding & Overturning = 0.0ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in (Service Level) Wind (W)= Design Summary Wall Stability Ratios Overturning =2.64OK Sliding =1.53OK Total Bearing Load =5,600lbs ...resultant ecc. =7.60in Soil Pressure @ Toe =1,438psf OK Soil Pressure @ Heel =351psf OK Allowable =1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe =2,014psf ACI Factored @ Heel =492psf Footing Shear @ Toe =28.7psi OK Footing Shear @ Heel =18.0psi OK Allowable =75.0psi Sliding Calcs Lateral Sliding Force =2,257.5lbs less 100% Passive Force less 100% Friction Force Added Force Req'd ....for 1.5 Stability = 0.0= 1,960.1 1,504.2 = = 0.0 - lbs lbs lbs OK lbs OK - Masonry Block Type =Medium Weight Stem Construction 3rd 2nd Stem OKStem OK Stem OK Bottom Shear.....Actual Design Height Above Ftg =3.50ft 1.00 0.00 Wall Material Above "Ht" =Concrete Concrete Concrete Thickness =8.00 8.00 8.00 Rebar Size =###5 5 5 Rebar Spacing = 9.00 9.00 9.00 Rebar Placed at = 6.25 i 6.25 i 6.25 i Design Data fb/FB + fa/Fa =0.279 0.711 0.965 Total Force @ Section =l bs Moment....Actual =ft-# Moment.....Allowable =10,717.8 10,717.8 10,717.8ft-# =p si Shear.....Allowable =75.0 75.0psi 75.0 Wall Weight = 100.0 100.0psf 100.0 Rebar Depth 'd'= 6.25in 6.25 6.25 Masonry Data f'm =psi Fs =psi Solid Grouting = Modular Ratio 'n'= Short Term Factor = Equiv. Solid Thick.= Concrete Data f'c =2,500.0 2,500.0psi 2,500.0 Fy =60,000.0 60,000.0 Masonry Design Method ASD= Load Factors Building Code IBC 2018,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 psi 60,000.0 Service Level = 1,315.4 2,451.3lbs 3,003.6Strength Level Service Level Strength Level = 2,993.3 7,628.7 10,351.5ft-# Service Level Strength Level = 17.5 32.7 40.0psi Design Method = LRFD LRFD LRFD Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Anet (Masonry)=in2 64 of 65 Hodge Engineering, Inc. 3733 Rosedale St. Ste. 200 Gig Harbor, WA. 98335 Title :10' Unrestrained 40 psf Surcharge Page : 2 Dsgnr:JEH Date: 11 JUN 2021 Description.... 10' Unrestrained wall with 40 psf surcharge This Wall in File: c:\users\johnhodge\documents\retainpro 10 project files\unrestrained walls 2.rpx RetainPro (c) 1987-2019, Build 11.20.03.31 Cantilevered Retaining Wall Code: IBC 2018,ACI 318-14,TMS 402-16License : KW-06053958License To : HODGE ENGINEERING Project Name/Number : unrestrained Concrete Stem Rebar Area Details 3rd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.1121 in2/ft (4/3) * As :0.1495 in2/ft Min Stem T&S Reinf Area 1.344 in2 200bd/fy : 200(12)(6.25)/60000 :0.25 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.4133 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.8467 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 2nd Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.2858 in2/ft (4/3) * As :0.3811 in2/ft Min Stem T&S Reinf Area 0.480 in2 200bd/fy : 200(12)(6.25)/60000 :0.25 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.2858 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.4133 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.8467 in2/ft #6@ 27.50 in #6@ 55.00 in ________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) :0.3878 in2/ft (4/3) * As :0.5171 in2/ft Min Stem T&S Reinf Area 0.192 in2 200bd/fy : 200(12)(6.25)/60000 :0.25 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.192 in2/ft 0.0018bh : 0.0018(12)(8) :0.1728 in2/ft Horizontal Reinforcing Options : ============One layer of : Two layers of : Required Area :0.3878 in2/ft #4@ 12.50 in #4@ 25.00 in Provided Area :0.4133 in2/ft #5@ 19.38 in #5@ 38.75 in Maximum Area :0.8467 in2/ft #6@ 27.50 in #6@ 55.00 in 2.80 3.46 12.00 Footing Torsion, Tu ==ft-lbs0 .00Min. As % Footing Allow. Torsion, phi Tu 0.0018 =ft-lbs Footing Data If torsion exceeds allowable, provide f'c 0.00 = 2,500psi Toe Width =ft Heel Width = Key Distance from Toe Key Depth Key Width =in =in = 8.00 14.00 2.80ft Footing Thickness =in 6.26= Cover @ Top =2.00 in@ Btm.=3.00in Total Footing Width =150.00pcfFooting Concrete Density Fy=60,000psi Footing Design Results Key: = #4@ 13.88 in, #5@ 18 in, #6@ 18 in, #7@ 18 in, #8@ 18 i Factored Pressure Mu' : Upward Mu' : Downward Mu: Design Actual 1-Way Shear Allow 1-Way Shear Toe:#4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46 #4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46 =# 4 @ 13.88 in = = = = = 2,014 83,819 14,633 5,766 28.73 75.00 Heel: 492 2,808 6,113 3,305 17.96 75.00 HeelToe psf ft-# ft-# ft-# psi psi Heel Reinforcing =# 4 @ 9.26 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 4 @ 9.25 in Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: 1.62 0.26 #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in in2 in2 /ft If two layers of horizontal bars: #4@ 18.52 in #5@ 28.70 in #6@ 40.74 in supplemental design for footing torsion. 65 of 65