Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Matthew Moore Permit Pack Stamped Flat
1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: February 9, 2024 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: DC SYSTEM SIZE: AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 7.15 kW AC 9.02 kW DC BLUE RAVENSOLAR PV1 Cover Sheet Brendan Fillmore ---- ---- ---- ---- 919050 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m Ye l m , W a s h i n g t o n 9 8 5 9 7 16 4 0 2 C a n a l C t S E Ma t t h e w M o o r e APPLICABLE CODESAHJ UTILITY COMPANY SHEET INDEX City of Yelm Puget Sound Energy *2020 NATIONAL ELECTRIC CODE (NEC) *2018 INTERNATIONAL BUILDING CODE (IBC) *2018 INTERNATIONAL RESIDENTIAL CODE (IRC), 2018 INTERNATIONAL PLUMBING CODE (IPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES PV Installation Professional Scott Gurney #PV-011719-015866 Enphase ðêÐÞ±ć ÂÞ RESIDENTIAL ROOFTOP SOLAR PERMIT PACKAGE Matthew Moore 16402 Canal Ct SE Yelm, Washington 98597 (910) 853-2353 PV1 PV2 PV3 PV4 PV5 PV6 PV7 PV8 SS COVER SHEET SITE PLAN ROOF PLAN STRUCTURAL ELECTRICAL 3-LINE ELECTRICAL CALCULATIONS LABELS PLACARD SPEC SHEETS SCOPE OF WORK INSTALLATION OF ROOFTOP MOUNTED PHOTVOLTAIC SOLAR SYSTEM TOTAL DC SYSTEM SIZE 9.020 kW DC TOTAL AC SYSTEM SIZE 7.150 kW AC NEW PV SYSTEM INFORMATION DC SYSTEM SIZE: AC SYSTEM SIZE: MODULE TYPE: INVERTER TYPE: 9.02kW DC 7.15 kW AC (22) Silfab Solar SIL-410 HC+ Enphase IQ8M-72-M-US DESIGN CRITERIA WIND SPEED: WIND EXPOSURE FACTOR: RISK CATEGORY: GROUND SNOW LOAD: ROOF SNOW LOAD: SEISMIC DESIGN CATEGORY: TYPICAL STRUCTURAL INFORMATION 110 C II D ROOF MATERIAL: SHEATHING TYPE: FRAMING TYPE: RACKING TYPE: ATTACHMENT TYPE: TOTAL ATTACHMENTS: Comp Shingle OSB Manufactured Truss UNIRAC SFM INFINITY UNIRAC SFM INFINITY FLASHKIT 53 INFORMATION FOR INSTALLER 0 0 ECOBEE QTY: LED LIGHTBULB QTY: WEATHER STATION DATA TACOMA NARROWS 28°C -4°C WEATHER STATION: HIGH TEMP 2% AVG: EXTREME MINIMUM TEMP: GENERAL NOTES SUNPO WER® Sealed For Existing Roof & Attachment Only 2/9/24 Digitally signed by John A. Calvert Date: 2024.02.09 11:02:35 -07'00' DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC M AC MSP CB N W S E 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: February 9, 2024 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: DC SYSTEM SIZE: AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 7.15 kW AC 9.02 kW DC BLUE RAVENSOLAR PV2 Site Plan Brendan Fillmore ---- ---- ---- ---- 919050 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m Ye l m , W a s h i n g t o n 9 8 5 9 7 16 4 0 2 C a n a l C t S E Ma t t h e w M o o r e SITE PLAN SCALE: 1/16" = 1'-0" UTILITY METER ROOF TOP JUNCTION BOX MAIN SERVICE PANEL SUBPANEL LEGEND AC DISCONNECT PV PRODUCTION METER COMBINER BOX BREAKER ENCLOSURE SUNPOWER HUB+ SUNVAULT ESS GENERATOR ATS PANEL UTILITY METER CT CABINET TRENCH OR OVERHEAD PROPERTY LINE REMOTE POWER OFF SWITCH FIRE SETBACK HATCH COMPASSPV SYSTEM SPECIFICATIONS PV MODULE: (22) Silfab Solar SIL-410 HC+, POWER RATING: 410 W MICROINVERTER: Enphase IQ8M-72-M-US, POWER RATING: 325 W NEW PV SYSTEM NEW PV SYSTEM INFORMATION M MSP SUB BE AC PV CB ATS CT HUB ESS RPO FRONT OF HOME 16402 Canal Ct SE "VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER." Sealed For Existing Roof & Attachment Only 2/9/24 DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC M AC MSP CB N W S E 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: February 9, 2024 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: DC SYSTEM SIZE: AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 7.15 kW AC 9.02 kW DC BLUE RAVENSOLAR PV3 Roof Plan Brendan Fillmore ---- ---- ---- ---- 919050 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m Ye l m , W a s h i n g t o n 9 8 5 9 7 16 4 0 2 C a n a l C t S E Ma t t h e w M o o r e UTILITY METER ROOF TOP JUNCTION BOX MAIN SERVICE PANEL SUBPANEL LEGEND AC DISCONNECT PV PRODUCTION METER COMBINER BOX BREAKER ENCLOSURE SUNPOWER HUB+ SUNVAULT ESS GENERATOR ATS PANEL UTILITY METER CT CABINET TRENCH OR OVERHEAD PROPERTY LINE REMOTE POWER OFF SWITCH FIRE SETBACK HATCH COMPASSPV SYSTEM SPECIFICATIONS PV MODULE: (22) Silfab Solar SIL-410 HC+, POWER RATING: 410 W MICROINVERTER: Enphase IQ8M-72-M-US, POWER RATING: 325 W NEW PV SYSTEM NEW PV SYSTEM INFORMATION M MSP SUB BE AC PV CB ATS CT HUB ESS RPO ROOF PLAN SCALE: 1/8" = 1'-0" FRONT OF HOME POINT OF INTERCONNECTION UNDERGROUND SERVICE LINE MP2 MODULE QTY: 9 AZIMUTH: 178 PITCH: 27 TSRF: 99 AREA: 400 ft² MP1 MODULE QTY: 13 AZIMUTH: 178 PITCH: 27 TSRF: 95 AREA: 668 ft² 3' 3' 3' 1'-6" 1'-6" 3' 1'-6" 1'-6" 3' 3' 3' "VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER." Sealed For Existing Roof & Attachment Only 2/9/24 FRAMING DETAIL SCALE: 1/2" = 1'-0"1 EXISTING FRAMINGROOF MATERIAL NOT SHOWN FOR CLARITY *THIS DETAIL IS NOT MEANT TO BE AN EXACT REPRESENTATION OF FRAMING OR PV MODULE LAYOUT EXTERIOR WALL PV MODULES SHALL NOT EXTEND ABOVE ROOF RIDGE LINE PV MODULE ATTACHMENT DETAIL SCALE: 1-1/2" = 1'-0"2 PV MODULE UNIRAC SFM INFINITY 2" MICRORAIL UNIRAC SFM INFINITY 6.5" SPLICE MAX CANTILEVER PER TABLE ABOVE (C) ATTACHMENT TYPE: Unirac SFM Infinity FRAMING SPACING PER TABLE ABOVE ATTACHMENT SPACING PER TABLE ABOVE (L) 212" MIN EMBEDMENT(1) 5/16" LAG BOLT WITH EPDM WASHER PORTRAITLANDSCAPE ATTACHMENT PATTERN SCALE: 1/4" = 1'-0"3 *ATTACHMENT PATTERN SHOULD BE STAGGERED UNLESS OTHERWISE NOTED IN ENGINEERING LETTER FOLLOW ATTACHMENT SPACING IN TABLE ABOVE RIDGE EAVE MP1 MP2 MP3 MP4 MP5 MP6 MP7 MP8 PANEL COUNT ROOF MATERIAL SHEATHING TYPE FRAMING TYPE FRAMING SIZE AND SPACING RACKING TYPE ATTACHMENT TYPE MAXIMUM ATTACHMENT SPACING (S) MAXIMUM CANTILEVER (C) CEILING JOIST/ PURLINS SIZE AND SPACING AZIMUTH (DEG) PITCH (DEG) TSRF (%) AREA (ft²) TOTAL PV ATTACHMENTS TOTAL PV ARRAY WEIGHT (lbs) POINT LOAD (lbs/att.) TOTAL ROOF AREA (ft²) TOTAL PV ARRAY AREA (ft²) ROOF COVERAGE (%) DISTRIBUTED LOAD (psf) MP9 MP10 13 178 27 95 668 Comp Shingle OSB Manufactured Truss 2x4 @ 24 in OC 2x4 @ 24 in OC UNIRAC SFM INFINITY UNIRAC SFM INFINITY FLASHKIT 72''L / 48''P 24''L / 16''P 9 178 27 99 400 Comp Shingle OSB Manufactured Truss 2x4 @ 24 in OC 2x4 @ 24 in OC UNIRAC SFM INFINITY UNIRAC SFM INFINITY FLASHKIT 72''L / 48''P 24''L / 16''P 0 0 0 0 0 0 0 0 1034 53 19.5 469.37 1986 2.2 23.63 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: February 9, 2024 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: DC SYSTEM SIZE: AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 7.15 kW AC 9.02 kW DC BLUE RAVENSOLAR PV4 Structural Brendan Fillmore ---- ---- ---- ---- 919050 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m Ye l m , W a s h i n g t o n 9 8 5 9 7 16 4 0 2 C a n a l C t S E Ma t t h e w M o o r e NOTES Sealed For Existing Roof & Attachment Only 2/9/24 EQUIPMENT DESCRIPTIONS PV MODULE: Silfab Solar SIL-410 HC+, 410 W DC, UL 1703 / UL 61730 COMPLIANTA MICROINVERTER: ENPHASE IQ8M-72-M-US, 325 W AC (0.325 kW), 1 PHASE, UL 1741 COMPLIANTB ROOFTOP JUNCTION BOX: EZ SOLAR JB-1.2 JUNCTION BOXC JUNCTION BOX: PVC 4 X 4 JUNCTION BOXD E F G H I J K L PV COMBINER BOX: ENPHASE IQ COMBINER 4 (X-IQ-AM1-240-4) M N O P Q R EQUIPMENT NOTES 1 2 3 4 5 6 7 8 9 10 11 12 S T LEGEND (E) SPD EXISTING (N)NEW (EL)EXISTING LOADS (RL)RELOCATED LOADS (PV)PV BREAKER (FIB)FACTORY INSTALLED BREAKER SURGE PROTECTIVE DEVICE GENERAL NOTES Utility Meter Number: 162375151 Supply Side Tap in MSP, Interior POI SQUARE-D SAFTEY SWITCH 60A, 2P, 240VAC, FUSIBLE (D222NRB) VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER. 6 AWG SOLID COPPER GEC TO BE IRREVERSIBLY SPLICED TO (E) GEC TO COMPLY WITH NEC 250.64(D)(1). GROUNDING ELECTRODE SYSTEM SHALL BE IN ACCORDANCE WITH NEC 250.53. UNDERGROUND SERVICE 120/240 VAC, 60 Hz 1 PHASE, 3 WIRE Utility Meter E N G (E) 200A Main Service Panel 9 (EL) (EL) (EL) (EL) (EL) (E) 200A G 40A FUSES AC DISCONNECT SAFETY SWITCH60A FUSIBLE F 5 8 N 5 SUPPLY SIDE TAP NEC 250.24(A) BOND GROUNDS AND NEUTRALS 4 L1 L2 G N PV CIRCUIT 1 PRIMARY PV COMBINER BOX N G G (22) PV MODULES & MICROINVERTERS PRIMARY STRUCTURE A B CD E 1 2ENVOY 15A (N) 20A 11 MODULES 1 PV ARRAY 1 3 1 PV ARRAY 2PV CIRCUIT 2 11 MODULES 2 (N) 20A 1 L1 (1) 12 AWG THHN/THWN-2 CU RED Exterior L2 (1) G (1) 12 AWG THHN/THWN-2 CU BLACK 6 AWG BARE, CU ENPHASE Q-CABLE, 2-WIRE, FREE AIR 4 L1 (1) 8 AWG THHN/THWN-2 CU RED Exterior3/4 INCH L2 (1) N (1) G (1) 8 AWG THHN/THWN-2 CU BLACK 8 AWG THHN/THWN-2 CU WHITE 10 AWG THHN/THWN-2 CU GREEN EMT 2 L1 (1) 10 AWG THHN/THWN-2 CU REDL2(1) G (1) 10 AWG THHN/THWN-2 CU BLACK 10 AWG THHN/THWN-2 CU GREEN 3/4 INCH * *TYPE NM (ROMEX)/UF CABLE IS PERMITTED FOR INTERIOR OR ATTIC RUNS AND SHALL BE USED WHEN NEC CODE PERMITS 3 L1 (2) 10 AWG THHN/THWN-2 CU REDL2(2) G (1) 10 AWG THHN/THWN-2 CU BLACK 10 AWG THHN/THWN-2 CU GREEN 3/4 INCH EMT *TYPE UF CABLE MAY BE SUBSTITUTED FOR USE IN CONDUIT WHERE NEC CODE PERMITS 5 L1 (1) 6 AWG THHN/THWN-2 CU RED Exterior3/4 INCH L2 (1) N (1) 6 AWG THHN/THWN-2 CU BLACK 6 AWG THHN/THWN-2 CU WHITE EMT FINAL CONFIGURATION OF PV CIRCUITS TO BE DECIDED BY INSTALLER. MUST COMPLY WITH MAX MICROINVERTERS PER CIRCUIT AS LISTED ON ATTACHED SPEC SHEET. ALL INTERIOR CONDUIT MUST BE SCH 80 PVC. OTHER NOTES MI MECHANICAL INTERLOCK 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: February 9, 2024 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: DC SYSTEM SIZE: AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 7.15 kW AC 9.02 kW DC BLUE RAVENSOLAR PV5 Electrical 3-Line Brendan Fillmore ---- ---- ---- ---- 919050 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m Ye l m , W a s h i n g t o n 9 8 5 9 7 16 4 0 2 C a n a l C t S E Ma t t h e w M o o r e NUMBER OF MODULES PER CIRCUIT PV CIRCUIT SPECIFICATIONS RATED AC OUTPUT CURRENT (IOUT) MINIMUM AMPACITY (IOUT x 125%) OVERCURRENT PROTECTION RATING CIRCUIT 1 PRIMARY STRUCTURE DETACHED STRUCTURE WIRE SIZE SPECIFICATIONS CONDUCTOR MATERIAL CONDUCTOR TYPE 1 2 3 4 5 6 7 8 9 10 MINIMUM CONDUCTOR AMPACITY 18.56A AC CONDUCTOR SIZE CONDUCTOR AMPACITY AMBIENT TEMPERATURE ADJUSTMENT FACTOR CONDUIT FILL ADJUSTMENT FACTOR ADJUSTED CONDUCTOR AMPACITY COMBINED AC OUTPUT CURRENT (COUT) MINIMUM AMPACITY (COUT x 125%) COMBINED PV BREAKER RATING WIRE RUN DISTANCE (FT) CALCULATED VOLTAGE DROP TOTAL VOLTAGE DROP WIRE TAG #1 WIRE TAG #2 WIRE TAG #3 WIRE TAG #4 WIRE TAG #5 WIRE TAG #6 TOTAL VOLTAGE DROP 0.86% 1% 0.31% 0.19% 0.12% 0% 2.480000% DATA SOURCE STATE CITY WEATHER STATION HIGH TEMP 2% AVG EXTREME MINIMUM TEMP ASHRAE Weather Station Data Washington Yelm ELECTRICAL INFORMATION UTILITY ELECTRICAL SYSTEM NEW PV SYSTEM QUANTITY TYPE OUTPUT CURRENT PV MODULES MICROINVERTERS WATTAGE TYPE NOMINAL VOLTAGE OUTPUT POWER 22 Silfab Solar SIL-410 HC+ 410W DC Enphase IQ8M-72-M-US 1.35A AC 240V AC 325W AC AC SYSTEM SIZE DC SYSTEM SIZE 7.15kW AC 9.02kW DC DESIGN LOCATION AND TEMPERATURES 1-Phase, 3-Wire, 60Hz, 120/240V 1-Phase, 3-Wire, 60Hz, 120/240V TACOMA NARROWS 28°C -4°C CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUIT 5 CIRCUIT 6 CIRCUIT 7 CIRCUIT 8 CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUIT 5 1111000000 00000 14.9A 14.9A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 18.6A 18.6A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 29.7A 37.1A 40AA 0.0A 0AA 0.0A CU THHN/THWN-2 12 AWG 30A 1 1 30A 18.56A AC 18.56A AC 37.24A AC 37.24A AC ----A AC ----A AC ----A AC ----A AC ----A AC CU CU CU CU ---- ---- ---- ---- ---- THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 ---- ---- ---- ---- ---- 10 AWG 10 AWG 8 AWG 6 AWG 40A 40A 55A 75A ----A ----A ----A ----A ----A 1 1 1 1 ---- ---- ---- ---- ---- 1 0.8 1 1 ---- ---- ---- ---- ---- 40A 32A 55A 75A ----A ----A ----A ----A ----A 72 65 20 10 10 ---- ---- ---- ---- ---- 0.86% 1% 0.31% 0.19% 0.12% 0% 0% 0% 0% 0% MAIN SERVICE PANEL BUSBAR RATING PANEL OCPD RATING AVAILABLE BACKFEED (120% RULE) PV BREAKER RATING SUBPANEL 1 SUBPANEL 2 200A 200A 40A 40A ----A ----A ##A ----A ----A ##A PV BREAKER BACKFEED CALCULATIONS NEC 705.12(B) -- "120% RULE" (BUSBAR RATING * 120%) - OCPD RATING = AVAILABLE BACKFEED *PV BREAKER MUST BE RATED LESS THAN OR EQUAL TO AVAILABLE BACKFEED FOR CODE COMPLIANCE* 40A 40A *THESE CALCULATIONS ARE ONLY APPLICABLE IF PV INTERCONNECTION IS A LOAD SIDE BREAKER* 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: February 9, 2024 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: DC SYSTEM SIZE: AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 7.15 kW AC 9.02 kW DC BLUE RAVENSOLAR PV6 Electrical Calculations Brendan Fillmore ---- ---- ---- ---- 919050 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m Ye l m , W a s h i n g t o n 9 8 5 9 7 16 4 0 2 C a n a l C t S E Ma t t h e w M o o r e UTILITY METER MAIN SERVICE PANEL SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS AC DISCONNECT RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PV COMBINER BOX PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS AUTHORIZED PERSONNEL ONLY NO DC WIRES PRESENT RAPID SHUTDOWN TEST NOT REQUIRED WARNING! WARNING LABELS FOR PHOTOVOLTAIC SYSTEM NET METER MULTIPLE SOURCES OF POWER CAUTION! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY. PV DISCONNECT IS LOCATED WITHIN 10 FT AND LINE OF SIGHT OF UTILITY METER. PHOTOVOLTAIC SYSTEM AC DISCONNECT!! 240 VNOMINAL OPERATING AC VOLTAGE RATED AC OUTPUT CURRENT 29.7 A ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING! DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING! IN CASE OF EMERGENCY, PLEASE CONTACT: BLUE RAVEN SOLAR (800) 377-4480 NOTICE LABELS WITH ROUND CORNERS ARE ADHESIVE STICKERS LABELS WITH SQUARE CORNERS ARE PLASTIC ENGRAVED PLACARDS 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com DRAWING TITLE: DRAWING NUMBER: February 9, 2024 PLOT DATE: DRAWN BY: REVISIONS: D PROJECT ID: DC SYSTEM SIZE: AC SYSTEM SIZE: CU S T O M E R N A M E : AH J : UT I L I T Y C O M P A N Y : C B A 7.15 kW AC 9.02 kW DC BLUE RAVENSOLAR PV7 Warning Labels Brendan Fillmore ---- ---- ---- ---- 919050 Pu g e t S o u n d E n e r g y Ci t y o f Y e l m Ye l m , W a s h i n g t o n 9 8 5 9 7 16 4 0 2 C a n a l C t S E Ma t t h e w M o o r e DRAWING NUMBER:SS BLUE RAVEN SOLAR SIL-410 HC+ SILFABSOLAR.COM * Chubb provides error and omission insurance to Silfab Solar Inc. RELIABLE ENERGY. DIRECT FROM THE SOURCE. Designed to outperform. Dependable, durable, high-performance solar panels engineered for North American homeowners. SILFAB SOLAR INC. 800 Cornwall Ave Bellingham WA 98225 USA T +1 360.569.4733 info@silfabsolar.com SILFABSOLAR.COM 1770 Port Drive Burlington WA 98233 USA T +1 360.569.4733 240 Courtneypark Drive East Mississauga ON L5T 2Y3 Canada T +1 905.255.2501 F +1 905.696.0267 Silfab - SIL-410-HC+-20230726 No reproduction of any kind is allowed without permission. Data and information is subject to modifications without notice. © Silfab Solar Inc., 2022. Silfab Solar® is a registered trademark of Silfab Solar Inc. ELECTRICAL SPECIFICATIONS 410 Test Conditions STC NOCT Module Power (Pmax) Wp 410 306 Maximum power voltage (Vpmax) V 38.99 36.24 Maximum power current (Ipmax) A 10.52 8.43 Open circuit voltage (Voc) V 45.59 42.76 Short circuit current (Isc) A 11.15 8.99 Module efficiency % 20.7% 19.3% Maximum system voltage (VDC) V 1000 Series fuse rating A 20 Power Tolerance Wp 0 to +10 Measurement conditions: STC 1000 W/m2 • AM 1.5 • Temperature 25 °C • NOCT 800 W/m2 • AM 1.5 • Measurement uncertainty ≤ 3% Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by 0 to +10W. MECHANICAL PROPERTIES / COMPONENTS METRIC IMPERIAL Module weight 21.3kg ±0.2kg 47lbs ±0.4lbs Dimensions (H x L x D) 1914 mm x 1036 mm x 35 mm 75.3 in x 40.8 in x 1.37 in Maximum surface load (wind/snow)* 5400 Pa rear load / 5400 Pa front load 112.8 lb/ft 2 rear load / 112.8 lb/ft2 front load Hail impact resistance ø 25 mm at 83 km/h ø 1 in at 51.6 mph Cells 132 Half cells - Si mono PERC 9 busbar - 83 x 166 mm 132 Half cells- Si mono PERC 9 busbar - 3.26 x 6.53 in Glass 3.2 mm high transmittance, tempered, anti-reflective coating 0.126 in high transmittance, tempered, anti-reflective coating Cables and connectors (refer to installation manual) 1350 mm, ø 5.7 mm, MC4 from Staubli 53 in, ø 0.22 in (12AWG), MC4 from Staubli Backsheet High durability, superior hydrolysis and UV resistance, multi-layer dielectric film, fluorine-free PV backsheet Frame Anodized Aluminum (Black) Bypass diodes 3 diodes-30SQ045T (45V max DC blocking voltage, 30A max forward rectified current) Junction Box UL 3730 Certified, IEC 62790 Certified, IP68 rated TEMPERATURE RATINGS Temperature Coefficient Isc +0.064 %/°C Temperature Coefficient Voc -0.28 %/°C Temperature Coefficient Pmax -0.36 %/°C NOCT (± 2°C) 45 °C Operating temperature -40/+85 °C WARRANTIES Module product workmanship warranty 25 years** Linear power performance guarantee 30 years ≥ 97.1% end 1st yr ≥ 91.6% end 12th yr ≥ 85.1% end 25th yr ≥ 82.6% end 30th yr SHIPPING SPECS Modules Per Pallet: 26 or 26 (California) Pallets Per Truck 32 or 30 (California) Modules Per Truck 832 or 780 (California) CERTIFICATIONS Product UL 61215-1:2017 Ed.1, UL 61215-2:2017 Ed.1, UL 61730-1:2017 Ed.1, UL 61730-2:2017 Ed.1 , CSA C22.2#61730-1:2019 Ed.2, CSA C22.2#61730-2:2019 Ed.2, IEC 61215-1:2016 Ed.1, IEC 61215-2:2016 Ed.1, IEC 61730-1:2016 Ed.2, IEC 61730-2:2016 Ed.2, IEC 61701:2020 (Salt Mist Corrosion), IEC 62716:2013 (Ammonia Corrosion), CEC Listing, UL Fire Rating: Type 2 Factory ISO9001:2015 * Warning. Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under “Warranty” at silfabsolar.com. PAN files generated from 3rd party performance data are available for download at: silfabsolar.com/downloads. Si d e Ba c k V i e w Pr o f i l e 75.3" [1914mm] 1. 4 " [ 3 5 m m ] 1.4" [35mm] 1. 4 " [ 3 5 m m ] 0.06" [1.5mm] 0.5" [12mm] 0. 3 " [ 7 m m ] 0. 6 " [ 1 5 m m ] 40 . 8 " [ 1 0 3 6 m m ] 12.1" [307mm]51.2 [1300mm] 12.1" [307mm] Ø0 . 1 7 " [ Ø 4 . 2 m m ] ( x 2 ) Gr o u n d i n g H o l e Mounting Hole (x4) Drainage Hole (x8) 39 . 2 " [ 9 9 6 m m ] 2.4" [60mm]8" [200mm] 53.15" [1350mm] Cable Length DRAWING NUMBER:SS BLUE RAVEN SOLAR IQ8M and IQ8A Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC), which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built using advanced 55-nm technology with high-speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to the IQ8 Series Microinverters that have integrated MC4 connectors. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conform with various regulations when installed according to the manufacturer’s instructions. Easy to install • Lightweight and compact with plug- and-play connectors • Power line communication (PLC) between components • Faster installation with simple two- wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB 3rd Ed.) NOTE: • IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, and so on) in the same system. • IQ Gateway is required to change the default grid profile at the time of installation to meet the local Authority Having Jurisdiction (AHJ) requirements. IQ8MA-MC4-DSH-00205-2.0-EN-US-2023-11-03 * Meets UL 1741 only when installed with IQ System Controller 2. ** IQ8M and IQ8A support split-phase, 240 V installations only. #ʏ?''US (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8M and IQ8A Microinverters B[{#ɷ#ɸ [B B}ȱZɽȰȫɽZɽ B}ȱɽȰȫɽZɽ Commonly used module pairings1 W 260–460 295–500 Module compatibility To meet compatibility, PV modules must be within the following maximum input DC voltage and maximum module Isc. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator MPPT voltage range V 30–45 32–45 Operating range V 16–58 Minimum/Maximum start voltage V 22/58 Maximum input DC voltage V 60 Maximum continuous input DC current A 12 Maximum input DC short-circuit current A 25 Maximum module Isc A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 ungrounded array; no additional DC side protection required; AC side protection requires max 20 A per branch circuit a{#ɷɸ [B B}ȱZɽȰȫɽZɽ B}ȱɽȰȫɽZɽ Peak output power VA 330 366 Maximum continuous output power VA 325 349 Nominal grid voltage (L-L) V 240, split-phase (L-L), 180° Minimum and Maximum grid voltage2 V 211-264 Maximum continuous output current A 1.35 1.45 Nominal frequency ?ų 60 Extended frequency range ?ų 47–68 AC short-circuit fault current over three cycles Arms 2 Maximum units per 20 A (L-L) branch circuit3 11 Total harmonic distortion % <5 Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable) 0.85 leading ... 0.85 lagging Peak efficiency %97.8 97.7 CEC weighted efficiency %97.5 97 Nighttime power consumption mW 21 22 Z'?[BT# Ambient temperature range -40°C to 60°C (-40°F to 140°F) Relative humidity range 4% to 100% (condensing) DC connector type Stäubli MC4 Dimensions (H × W × D) 212 mm (8.3") × 175 mm (6.9") × 30.2 mm (1.2") Weight 1.1 kg (2.43 lbs) Cooling Natural convection–no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor IQ8MA-MC4-DSH-00205-2.0-EN-US-2023-11-03 B}ȱZɽȰȫ ɽZɽ 260–460 B}ȱZɽȰȫ ɽZɽ 330 325 1.35 97.8 97.5 DRAWING NUMBER:SS BLUE RAVEN SOLAR The Enphase Q Cable™ and accessories are part of the latest generation Enphase IQ System™. These accessories provide simplicity, reliability, and faster installation times. Enphase Q Cable Accessories To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Q Cable Accessories REGION: Americas Enphase Q Cable • Two-wire, double-insulated Enphase Q Cable is 50% lighter than the previous generation Enphase cable • New cable numbering and plug and play connectors speed up installation and simplify wire management • Link connectors eliminate cable waste Field-Wireable Connectors • Easily connect Q cables on the roof without complex wiring • Make connections from any open connector and center feed any section of cable within branch limits • Available in male and female connector types To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-06-26 CONDUCTOR SPECIFICATIONS 'IVXMƤGEXMSR UL3003 (raw cable), UL 9703 (cable assemblies), DG cable Flame test rating FT4 Compliance RoHS, OIL RES I, CE, UV Resistant, combined UL for Canada and United States Conductor type THHN/THWN-2 dry/wet Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Q CABLE TYPES / ORDERING OPTIONS Connectorized Models Size / Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG / 277 VAC 1.3 m (4.2 ft) Portrait 240 Q-12-17-240 12 AWG / 277 VAC 2.0 m (6.5 ft) Landscape (60-cell) 240 Q-12-20-200 12 AWG / 277 VAC 2.3 m (7.5 ft) Landscape (72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Field-wireable connector (male)Q-CONN-10M Make connections from any open connector Field-wireable connector (female)Q-CONN-10F Make connections from any Q Cable open connector Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount Q Cable sealing caps (female)Q-SEAL-10 One needed to cover each unused connector on the cabling Terminator Q-TERM-10 Terminator cap for unused cable ends Enphase EN4 to MC4 adaptor¹ECA-EN4-S22 Connect PV module using MC4 connectors to IQ micros with EN4 (TE PV4-S SOLARLOK). 150mm/5.9” to MC4. Enphase EN4 non-terminated adaptor¹ECA-EN4-FW *SVƤIPH[MVMRKSJ90GIVXMƤIH('GSRRIGXSVW)28)4:7730 %603/ XS non-terminated cable. 150mm/5.9” Enphase EN4 to MC4 adaptor (long)¹ECA-EN4-S22-L Longer adapter cable for EN4 (TE PV4-S SOLARLOK) to MC4. Use with split cell modules or PV modules with short DC cable. 600mm/23.6” Replacement DC Adaptor (MC4)Q-DCC-2 DC adaptor to MC4 (max voltage 100 VDC) Replacement DC Adaptor (UTX)Q-DCC-5 DC adaptor to UTX (max voltage 100 VDC) 1. 5YEPMƤIHTIV90WYFNIGX Enphase Q Cable Accessories TERMINATOR Terminator cap for unused cable ends, sold in packs of ten (Q-TERM-10) SEALING CAPS Sealing caps for unused aggregator and cable connections (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL Plan to use at least one per installation, sold in packs of ten (Q-DISC-10) CABLE CLIP Used to fasten cabling to the racking or to secure looped cabling, sold in packs of one hundred (Q-CLIP-100) 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. SHEET NAME: PAGE NUMBER:REVISION: 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEETS SS 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS The Enphase IQ Envoy™ communications gateway delivers solar production and energy consumption data to Enphase Enlighten™ monitoring and analysis software for comprehensive, remote maintenance and management of the Enphase IQ System. With integrated revenue grade production metering and optional consumption monitoring, Envoy IQ is the platform for total energy management and integrates with the Enphase Ensemble™and the Enphase IQ Battery™. Enphase IQ Envoy To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Enables web-based monitoring and control • Bidirectional communications for remote upgrades • Supports power export limiting and zeroexport applications Simple ŵ )EW] W]WXIQ GSRƤKYVEXMSR YWMRK Enphase Installer Toolkit™ mobile app • Flexible networking with Wi-Fi, Ethernet, or cellular Reliable • Designed for installation indoors or outdoors • Five-year warranty To learn more about Enphase offerings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Envoy, and other trademarks or service names are the trade- marks of Enphase Energy, Inc. Data subject to change. 06-30-2021 MODEL NUMBERS Enphase IQ Envoy™ ENV-IQ-AM1-240 Enphase IQ Envoy communications gateway with integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional consumption monitoring (+/- 2.5%). Includes one 200A continuous rated production CT (current transformer). ACCESORIES (Order Seperately) Enphase Mobile Connect™ CELLMODEM-M1 (4G based LTE-M/5-year data plan) CELLMODEM-M1-B (4G-based LTE-M1/5-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Consumption Monitoring CT CT-200-SPLIT Split-core consumption CTs enable whole home metering. Ensemble Communications Kit COMMS-KIT-01 Installed at the IQ Envoy. For communications with Enphase Encharge™ storage and Enphase Enpower™ smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner™ and allows wireless communication with Encharge and Enpower. POWER REQUIREMENTS Power requirements 120/240 VAC split-phase. Max 20 A overcurrent protection required. Typical Power Consumption 5W CAPACITY Number of microinverters polled Up to 600 MECHANICAL DATA Dimensions (WxHxD) 21.3 x 12.6 x 4.5 cm (8.4” x 5” x 1.8”) Weight 17.6 oz (498 g) Ambient temperature range -40° to 65° C (-40° to 149° F) -40° to 46° C (-40° to 115° F) if installed in an enclosure Environmental rating -4*SV MRWXEPPEXMSR MRHSSVW SV MR ER 2680GIVXMƤIH 2)1% X]TI 6 IRGPSWYVI Altitude To 2000 meters (6,560 feet) Production CT - Limited to 200A of continuous current / 250A OCPD – 72kW AC - Internal aperture measures 19.36mm to support 250MCM THWN conductors (max) - 90 GIVXMƤIH JSV VIZIRYI KVEHI QIXIVMRK Consumption CT - For electrical services to 250A with parallel runs up to 500A - Internal aperture measures 0.84” x 0.96” (21.33mm x 24.38mm) to support 3/0 THWN conductor 90GIVXMƤIHJSVYWIEXWIVZMGIIRXVERGIJSVWIVZMGIWYTXS:EG INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Mobile CELLMODEM-M1 (4G) or CELLMODEM-M1-B (4G). Not included. Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. COMPLIANCE Compliance UL 61010-1 CAN/CSA C22.2 No. 61010-1 47 CFR, Part 15, Class B, ICES 003 IEC/EN 61010-1:2010, EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2 Metering: ANSI C12.20 accuracy class 0.5 (PV production only) Enphase IQ Envoy 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SSPROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EZ SOLAR. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. Phone: 385-202-4150 www.ezsolarproducts.com ITEM No. 1 1 1 6 6 JB-1.2 Body POLYCARBONATE WITH UV INHIBITORS POLYCARBONATE WITH UV INHIBITORS #10 x 1-1/4” Phillips pan head screw #8 x 3/4” Phillips pan head screw JB-1.2 Lid2 3 4 PART NUMBER DESCRIPTION QTY Size SCALE: 1:2 WEIGHT: 1.45 LBS SHEET 1 of 3 DWG. NO. Rev B JB-1.2 Torque Specification: certification: WEIGHT: 15-20 LBS 1.45 LBS UL Standard 1741, nema 3r JB-1.2 Specification Sheet PV Junction Box for Composition/Asphalt Shingle Roofs • Maximum Voltage: 1,000 Volts • Maximum Current: 80 Amps • Allowable Wire: 14 AWG – 6 AWG • Spacing: Please maintain a spacing of at least ½” between uninsulated live parts and fittings for conduit, armored cable, and uninsulated live parts of opposite polarity. • Enclosure Rating: Type 3R • Roof Slope Range: 2.5 – 12:12 • Max Side Wall Fitting Size: 1” • Max Floor Pass-Through Fitting Size: 1” • Ambient Operating Conditions: (-35°C) - (+75°C) • Compliance: - JB-1.2: UL1741 - Approved wire connectors: must conform to UL1741 • System Marking: Interek Symbol and File #5019942 • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion between components, components that are found to be affected are to be replaced immediately. A. System Specifications and Ratings Phone: 385-202-4150 | www.ezsolarproducts.com 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS www.carlon.com180 Rigid Nonmetallic Conduit – Junction Boxes Molded Nonmetallic Junction Boxes 6P Rated It’s another first from Carlon®- the first nonmetallic junction boxes UL Listed with a NEMA 6P rating per Section 314.29, Exception of the National Electrical Code. Manufactured from PVC or PPO thermoplastic molding compound and featuring foam-in-place gasketed lids attached with stainless steel screws, these rugged enclosures offer all the corrosion resistance and physical properties you need for direct burial applications. Type 6P enclosures are intended for indoor or outdoor use, primarily to provide a degree of protection against contact with enclosed equipment, falling dirt, hose- directed water, entry of water during prolonged submersion at a limited depth, and external ice formation. • All Carlon Junction Boxes are UL Listed and maintain a minimum of a NEMA Type 4/4x Rating. • Parts numbers with an asterisk (*) are UL Listed and maintain a NEMA Type 6P Rating and Type 4/4X Rating. E42728Except where noted by † Size in Std.Material Std. Inches Ctn. Min Min. Min. Min. Ta Tc Thermo-Ctn. Part No. H x W x D Qty.AT AB B C PVC plastic Wt. (Lbs.) E989NNJ-CAR* 4 x 4 x 2 5 3 11/16 3 5/8 N/A 2 .160 .155 X 3 E987N-CAR* 4 x 4 x 4 5 3 11/16 3 1/2 N/A 4 .160 .155 X 4 †E989NNR-CAR* 4 x 4 x 6 4 3 11/16 3 3/8 N/A 6 .160 .200 X 5 E989PPJ-CAR* 5 x 5 x 2 4 4 11/16 41/2 N/A 2 .110 .150 X 3 E987R-CAR* 6 x 6 x 4 2 6 5 5/8 N/A 4 .190 .190 X 3 E989RRR-UPC* 6 x 6 x 6 8 5 5/8 53/8 N/A 6 .160 .150 X 14 E989N-CAR 8 x 8 x 4 1 8 8 N/A 4 .185 .190 X 2 E989SSX-UPC 8 x 8 x 7 2 7 21/32 7 5/16 N/A 7 .160 .150 X 6 E989UUN 12 x 12 x 4 3 11 5/8 111/2 111/8 4 .160 .150 X 12 E989R-UPC 12 x 12 x 6 2 11 15/16 117/8 117/16 6 .265 .185 X 10 Typical Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com DRAWING NUMBER:SS BLUE RAVEN SOLAR “Stay Connected” with Solar Power Components ® 1-4b1-800-526-4182 • 732-286-1800 (NJ) • FAX: 732-244-8843 • www.heyco.com Heyco®-Tite Liquid Tight Cordgrips for Enphase Q Cables Straight-Thru, NPT Hubs with Integral Sealing Ring The Ultimate in Liquid Tight Strain Relief Protection •Two new cordgrips now accommodate the Enphase Q Cable – M3231GCZ (1/2˝ NPT) and M3234GDA-SM (3/4˝ NPT). •The 1/2˝ version provides liquid tight entry for one Enphase Q Cable – .24 x .38˝ (6,1 x 9,7 mm). •The 3/4˝ version provides liquid tight entry for up to two Enphase Q Cables – .24 x .38” (6,1 x 9,7 mm) and an additional .130” (3,3 mm) dia. hole for a #8 solid grounding cable. •The 3/4˝ version utilizes our skinned- over technology so any unused holes will retain a liquid tight seal. •Rated for use with DG Cable. Material Nylon 6/6 with TPE Sealing Gland Certifications Listed under Underwriters’ Laboratories File E504900 CSA Certified by the Canadian Standards Association File 93876 Flammability Rating 94V-2 Temperature Range Static -40°F (-40°C) to 239°F (115°C) Dynamic -4°F (-20°C) to 212°F (100°C) IP Rating IP 68 GLAND PART NO. DESCRIPTION PART DIMENSIONS CONFIGURATION A B C D E Conductors or Clearance Max. O.A. Thread Wrenching Nut Type Size No. Black Hole Dia. Length Length Thickness Flat Size * mm. in. mm. in. mm. in. mm. in. mm. in. mm. Oval Gland Q Cable 6,1x 9,7 1 M3231GCZ LTCG 1/2 6.1x9.7MM .875 22,2 1.70 43,2 .61 15,5 .21 5,3 .98 24,9 Break-Thru Skinned Over Gland Q Cables 6,1x 9,7 2 SMCG 3/4 2-6.1x9.7MMplusM3234GDA-SM 1.040 26,4 2.00 50,8 .62 15,7 .25 6,4 1.30 33,0 Ground 3,3 1 1-3.3MM Metal Locknuts INCLUDED. Heyco®Helios®UVX Clip – Blind Mount •The jersey pine tree mounting style installs easily with superior holding power. •UVX nylon protects from corrosion due to outdoor exposure. •Installs into .260˝ (6,6 mm) mounting hole. •Holds up to 2 cables between .230 - .315˝ (5,8 - 8,0 mm) each. •Cables install with fingertip pressure. •Molded from our robust UVX nylon 6/6 with extended UV capabilities for our Solar 20 Year Warranty. Material Nylon 6/6 with extended UV Capabilities Flammability Rating 94V-2 Temperature Range Dynamic -4°F (-20°C) to 185°F (85°C) PANEL THICKNESS RANGE WIRE DIAMETER PART NO. DESCRIPTION MOUNTING OVERALL RANGE HOLE DIA. HEIGHT Minimum Maximum 1-2 Wires A C in. mm. in. mm. in. mm. in. mm. 1-2 Wires .028 0,7 .250 6,4 .23 (5,8 mm) - .32 (8,0 mm)S6520 Helios UVX Clip 100 Pack .260 6,6 .96 24,4each cable S6560 Helios UVX Clip Bulk SUGGESTED CLEARANCE HOLE FOR NONTHREADED MOUNTING AD C B E SEALING NUT INTEGRAL SEALING RING ALL NEW PRODUCT! ALL NEW PRODUCT! The 3/4˝ version provides liquid tightpqg entry for up to two Enphase Q Cables –yp p .24 x .38” (6,1 x 9,7 mm) and an (, , ) additional .130” (3,3 mm) dia. hole for(, ) a #8 solid grounding cable. Q Cables 6,1x9,7 2 SMCG 3/4 2-6.1x9.7MMplusM3234GDA-SM 1.040 26,4 2.00 50,8 .62 15,7 .25 6,4 1.30 33,01-3.3MM3,3 1Ground Break-Thru Skinned Over Gland The 3/4˝ version utilizes our skinned- over technology so any unused holes gy y will retain a liquid tight seal. DRAWING NUMBER:SS BLUE RAVEN SOLAR SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS, FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION AND SERVICE. SFM INFINITY 20% FEWER ATTACHMENTS Save time and money on every project: SFM INFINITY requires fewer attachments than rail systems. 2 INSTALLS PER DAY Make two installs per day your new standard. SFM INFINITY has fewer roof attachments, one tool installation, and pre-assembled components to get you off the roof 40% faster. BETTER AESTHETICS Install the system with the aesthetics preferred by homeowners, with integrated front trim, trim end caps, dark components, and recessed hardware. 30% LOGISTICS SAVINGS With fewer SKUs and compact components, SFM INFINITY is easier to stock, easier to transport, and easier to lift to the roof. Plus, make more efficient use of your vehicle fleet. SYSTEM OVERVIEW BONDING AND ACCESSORIES 2MW 3MW PART NAME DESCRIPTION TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules N/S BONDING CLAMP Electrically bonds rows of modules 2 3 4 5 6 1 1 4 3 5 6 7 SFM INFINITY 15 Attachments RAIL 20 Attachments 87%OF HOMEOWNERS PREFER MAXIMUM POWER DENSITY Easily mix module orientations to achieve optimal power density without incurring the increased bill of materials, labor, and attachments required by rail. 7 2 PART NAME DESCRIPTION TRIMRAIL Structural front trim provides aesthetic and aligns modules. TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof. Available for comp shingle or tile. MODULE CLIPS Secure modules to TRIMRAIL. MICRORAIL Connects modules to SLIDERS. Provides post-install array leveling. SPLICE Connects and supports modules. Provides east-west bonding. ATTACHED SPLICE also available. SLIDER FLASHKIT Roof attachment and flashing. Available for comp shingle and tile. DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 19SYSTEM BONDING & GROUNDING E-W BONDING PATH: (:PRGXOHWRPRGXOHERQGLQJLVDFFRPSOLVKHG ZLWKSUHLQVWDOOHGERQGLQJSLQVZKLFKHQJDJH RQWKHVHFXUHVLGHRIWKH0LFURUDLO70DQGVSOLFH TRIMRAIL BONDING PATH: 7ULPUDLOWRPRGXOHERQGLQJLVDFFRPSOLVKHGZLWK ERQGLQJFODPSZLWKLQWHJUDOERQGLQJSLQDQG ERQGLQJ7EROW(refer also to alternate method) N-S BONDING PATH: 16PRGXOHWRPRGXOHERQGLQJLV DFFRPSOLVKHGZLWKERQGLQJFODPSZLWKLQWHJUDO ERQGLQJSLQV(refer also to alternate method) System bonding is accomplished through modules. System grounding accomplished by attaching DJURXQGOXJWRDQ\PRGXOHDWDORFDWLRQRQWKHPRGXOHVSHFLʳHGE\WKHPRGXOHPDQXIDFWXUHU LUG DETAIL & TORQUE INFO Ilsco Lay-In Lug (GBL-4DBT) • PRXQWLQJKDUGZDUH • 7RUTXH IWOE • $:*6ROLGRU6WUDQGHG LUG DETAIL & TORQUE INFO Ilsco Flange Lug (SGB-4) • ȧPRXQWLQJKDUGZDUH • 7RUTXH LQOE • $:*6ROLGRU6WUDQGHG LUG DETAIL & TORQUE INFO Wiley WEEBLug (6.7) • ȧPRXQWLQJKDUGZDUH • 7RUTXH IWOE • $:*6ROLGRU6WUDQGHG NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION TERMINAL TORQUE, Install Conductor and torque to the following: 4-6 AWG: 35in-lbs 8 AWG: 25 in-lbs 10-14 AWG: 20 in-lbs TERMINAL TORQUE, Install Conductor and torque to the following: 6-14 AWG: 7ft-lbs TERMINAL TORQUE, Install Conductor and torque to the following: 4-14 AWG: 35in-lbs WEEBLUG Single Use Only Star Washer is Single Use Only Ñ $OWHUQDWHPHWKRG $OWHUQDWHPHWKRG DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 20UL CODE COMPLIANCE NOTES SYSTEM LEVEL FIRE CLASSIFICATION 7KHV\VWHPʳUHFODVVUDWLQJUHTXLUHVLQVWDOODWLRQLQWKHPDQQHUVSHFLʳHGLQWKH 681)5$0(0,&525$,/6)0,QVWDOODWLRQ*XLGH6)0KDVEHHQFODVVLʳHGWR WKHV\VWHPOHYHOʳUHSRUWLRQRI8/7KLV8/FODVVLʳFDWLRQKDVEHHQ LQFRUSRUDWHGLQWRWKH8/SURGXFWFHUWLʳFDWLRQ6)0KDVDFKLHYHG&ODVV$ % &V\VWHPOHYHOSHUIRUPDQFHIRUORZVORSH VWHHSVORSHGURRIVZKHQXVHG LQFRQMXQFWLRQZLWKW\SHDQGW\SHPRGXOHV&ODVV$% &V\VWHPOHYHOʳUH UL2703 TEST MODULES 6HHSDJHVDQGIRUDOLVWRIPRGXOHVWKDWZHUHHOHFWULFDOO\DQGPHFKDQLFDOO\WHVWHGRU TXDOLʳHGZLWKWKH681)5$0(0,&525$,/6)0FRPSRQHQWVRXWOLQHGZLWKLQWKLV,QVWDOODWLRQ*XLGH •0D[LPXP$UHDRI0RGXOH VTIW •8/'HVLJQ/RDG5DWLQJV D 'RZQZDUG3UHVVXUHȡ36)3D E 8SZDUG3UHVVXUHȡ36)3D F 'RZQ6ORSH/RDGȡ36)3D •7HVWHG/RDGV D 'RZQZDUG3UHVVXUHȡ36)3D E 8SZDUG3UHVVXUHȡ36)3D F 'RZQ6ORSH/RDGȡ36)3D •0D[LPXP6SDQ IW •8VHZLWKDPD[LPXPRYHUFXUUHQWSURWHFWLRQGHYLFH2&3'RI$ •6\VWHPFRQIRUPVWR8/6WGFHUWLʳHGWR/75$( •5DWHGIRUDGHVLJQORDGRI3D3DZLWKLQFKVSDQ •39PRGXOHVPD\KDYHDUHGXFHGORDGUDWLQJLQGHSHQGHQWRIWKH6)0ORDGUDWLQJ3OHDVHFRQVXOW WKH39PRGXOHPDQXIDFWXUHU VLQVWDOODWLRQJXLGHIRUPRUHLQIRUPDWLRQ •'RZQ6ORSHGHVLJQORDGUDWLQJRI36)3DIRUPRGXOHDUHDVRIVTIWRUOHVV Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 6WHHS6ORSH /RZ6ORSH &ODVV$% & (DVW:HVW /DQGVFDSH253RUWUDLW None Required SHUIRUPDQFHLVLQKHUHQWLQWKH6)0GHVLJQDQGQRDGGLWLRQDOPLWLJDWLRQPHDVXUHV DUHUHTXLUHG7KHʳUHFODVVLʳFDWLRQUDWLQJLVYDOLGIRUDQ\URRISLWFK7KHUHLVQR UHTXLUHGPLQLPXPRUPD[LPXPKHLJKWOLPLWDWLRQDERYHWKHURRIGHFNWRPDLQWDLQ WKH&ODVV$% &ʳUHUDWLQJIRU6)0681)5$0(0,&525$,/TM FRPSRQHQWVVKDOO EHPRXQWHGRYHUDʳUHUHVLVWDQWURRIFRYHULQJUDWHGIRUWKHDSSOLFDWLRQ DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 22TESTED / CERTIFIED MODULE LIST Aleo P-Series $SWRV '1$%)0) '1$%)0) $VWURQHUJ\ &+603&+603+9&+600 &+600+9&+600%/%)+) CHSM72M-HC Auxin $;107$;137 $;107 $;137 $[LWHF $;,EODFNSUHPLXPPP $;,SRZHUPP $;,SRZHUPP $;,SUHPLXPPP $;,SUHPLXPPP %RYLHW %90 %90 %<'P6K & MHK-36 Series Canadian Solar &6+.8<06 &6./8&6.0%$*&6.063 &6106&680%$*&68063&6: &6$0&6.8&6.03&6.06 &6303&6803&690&6;3 &HQWURVRODU$PHULFD C-Series & E-Series &HUWDLQ7HHG &7[[0[[&7[[3[[ &7[[[0[[&7[[[0 &7[[[0[[&7[[[+& 'HKXL '+0 Manufacture Module Model / Series Eco Solargy Orion 1000 & Apollo 1000 ET Solar ET-M672BHxxxTW )UHHGRP)RUHYHU FF-MP-BBB-370 )UHH9ROW Mono PERC GCL GCL-P6 & GCL-M6 Series Hansol 7'$17'$1 8%$18'$1 Heliene 0030 36HULHV +&00RQRIDFLDO%LIDFLDO6HULHV +&06/%LIDFLDO HT Solar +701'9) +703 Hyundai .*0*7*5,5*7,0,+, .,6HULHV HiA-SxxxHG ,7(. L7L7+( L76(6HULHV Japan Solar JPS-60 & JPS-72 Series JA Solar -$3[[[-$0[[[6,-$0. [[[-$3N[[[%%-$36<<[[[== -$3N[[[%%-$36<<[[[== -$0N[[[==-$06<<[[[== -$0N[[[==-$06<<[[[== L<< LL==6&35%3+L7,%0:05 -LQNR JKM & JKMS Series Eagle JKMxxxM -.0[[[0+/9 Kyocera KU Series Manufacture Module Model / Series Manufacture Module Model / Series ȫ8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ ȫ,WHPVLQSDUHQWKHVLVDUHWKRVHWKDWPD\RUPD\QRWEHSUHVHQWLQDFRPSDWLEOHPRGXOH VPRGHO,' ȫ6ODVKHVEHWZHHQRQHRUPRUHLWHPVLQGLFDWHVWKDWHLWKHURIWKRVHLWHPVPD\EHWKHRQHWKDWLVSUHVHQWLQDPRGXOH VPRGHO,' ȫ3OHDVHVHHWKH6)08/&RQVWUXFWLRQ'DWD5HSRUWDW8QLUDFFRPWRHQVXUHWKHH[DFWVRODUPRGXOHVHOHFWHGLVDSSURYHGIRUXVHZLWK6)0 ȫ6)0,QʳQLW\LVQRWFRPSDWLEOHZLWKPRGXOHIUDPHKHLJKWRIOHVVWKDQPPDQGPRUHWKDQPP6HH0RGXOH0RXQWLQJVHFWLRQSDJHIRUIXUWKHULQIRUPDWLRQ /*(OHFWURQLFV LGxxxN2T-A4 /*[[[$&(&(.1&1.171: 4&4.6&6:$ LGxxxN2T-B5 LGxxxN1K-B6 /*[[[$&0&0.1&1.4&4. 4$&4$.$ /*[[[1&1.171:( /*[[[1&1.1:6&6:* LGxxxN2T-J5 /*[[[1.1:171:/ /*[[[1&4&4.1 /*[[[1&1.1:4&4.9 LONGi /5+,%+,++3%+3+[[[0 /5+,++3+[[[0 /5%3+%'+,%'[[[0PP /5%.3(+3%+3+[[[0PP /5%.3(3%3+[[[0PP /5%3+%'+,%'[[[0PP /5+9%.3(3+3%+3+[[[0 PP /5%.+93(3%3+[[[0PP Mission Solar Energy MSE Series 0LWVXELVKL MJE & MLE Series 1HR6RODU3RZHU&R '0 '36HULHV DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 23TESTED / CERTIFIED MODULE LIST 5(&6RODUFRQW 7ZLQ3HDN6HULHV 7ZLQ3HDN6HULHV 7ZLQ3HDN%/.6HULHV 7ZLQ3HDN60;9 7ZLQ3HDN6HULHVPP 73%ODFN Renesola 9LWUXV6HULHV 6HULHV Risen 5600'*0560 SEG Solar 6(*[[[%0'+9 6(*[[[%0'7% S-Energy 61 616HULHVPP Seraphim SEG-6 & SRP-6 Series Sharp NU-SA & NU-SC Series 6LOIDE 6/$6/*%&6HULHV 6,/[[[%/1/17+/ 0/%.1;18+& 6RODUHYHU86$ 6( [[[01 Solaria 3RZHU;7[[[5$&3'%' 3RZHU;7[[[&3' 3RZHU;7[[[530$& SolarWorld 6XQPRGXOH3URWHFW Sunmodule Plus Sonali 660WR6HULHV 660WR6HULHV 660WR6HULHV 660WR%L)DFLDO6HULHV SS 230 - 265 SunEdison )6HULHV56HULHV )/(;);66HULHV Manufacture Module Model / Series 6XQLYD 096HULHV 2SWLPXV6HULHV SunPower $6HULHV$%/.6350$;;;;5 ;6HULHV(6HULHV 36HULHV 6XQWHFK 673673;;;6%:QKE Talesun 73737373 73+LSRU06PDUW Tesla 6&6&%6&%6&% 7[[[+7[[[6 Trina 3$3''''(''3( 3'3('''('('( PE15H Upsolar 830[[[3% 830[[[0% 8QLWHG5HQHZDEOH(QHUJ\ 85( '0[[[+$'0.[[[+$ )$.[[[&*(*)$0[[[(*%% )$0[[[(*%% FBMxxxMFG-BB 9LNUDP (OGRUD 6ROLYR Somera Waaree AC & Adiya Series Winaico WST & WSP Series Yingli YGE & YLM Series =16KLQH =;0=;01+B Manufacture Module Model / Series Manufacture Module Model / Series ȫ8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ ȫ,WHPVLQSDUHQWKHVLVDUHWKRVHWKDWPD\RUPD\QRWEHSUHVHQWLQDFRPSDWLEOHPRGXOH VPRGHO,' ȫ6ODVKHVEHWZHHQRQHRUPRUHLWHPVLQGLFDWHVWKDWHLWKHURIWKRVHLWHPVPD\EHWKHRQHWKDWLVSUHVHQWLQDPRGXOH VPRGHO,' ȫ3OHDVHVHHWKH6)08/&RQVWUXFWLRQ'DWD5HSRUWDW8QLUDFFRPWRHQVXUHWKHH[DFWVRODUPRGXOHVHOHFWHGLVDSSURYHGIRUXVHZLWK6)0 ȫ6)0,QʳQLW\LVQRWFRPSDWLEOHZLWKPRGXOHIUDPHKHLJKWRIOHVVWKDQPPDQGPRUHWKDQPP6HH0RGXOH0RXQWLQJVHFWLRQSDJHIRUIXUWKHULQIRUPDWLRQ Panasonic (939[[[+.3. 9%+1[[[6$ 6$ 9%+1[[[6$ 6$ 9%+1[[[6$(* 6$( 9%+1[[[.$ .$ .$ 9%+1[[[=$9%+1[[[=$ 9%+1[[[=$9%+1[[[=$ Peimar 6*[[[0)%%) Phono Solar 3636 Prism Solar P72 Series 4&HOOV 3OXV3UR3HDN****** 3UR3HDN/*/*/*/*/* 43($.'82%/.* 43($.'82%/.*76 43($.'82%/.* 43($.'82/*%)) 43($.'82%/.0/* 43($.'82;/*** 43($.'82%/.0/* 43($.'82;/*FG 43($.'82%/.0/*W REC Solar $OSKD%ODFN3XUH RECxxxAA PURE-R 5(&[[[13%ODFN 13HDN%ODFN 13HDN%ODFN PEAK Energy Series PEAK Energy BLK2 Series PEAK Energy 72 Series DRAWING NUMBER:SS BLUE RAVEN SOLAR DRAWING NUMBER:SS BLUE RAVEN SOLAR DRAWING NUMBER:SS BLUE RAVEN SOLAR Listing Constructional Data Report (CDR) Report Number 102393982LAX-002 Original 11-Apr-2016 Revised: 5-Oct-2022 Standard(s) Applicant Manufacturer 2 Address Address Country Country Contact Contact Phone Phone FAX FAX Email Email Manufacturer 3 Manufacturer 4 Address Address Country Country Contact Contact Phone Phone FAX FAX Email Email Manufacturer 5 Address Country Contact Phone FAX 505-462-2190 505-843-1418 NA klaus.nicolaedis@unirac.com toddg@unirac.com 1411 Broadway Blvd NE Albuquerque, NM 87102 USA Klaus Nicolaedis Todd Ganshaw 1.0 Reference and Address Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No. A-40:2020] Unirac, Inc Page 1 of 138 Listing Constructional Data Report (CDR) Report Number 102393982LAX-002 Original 11-Apr-2016 Revised: 5-Oct-2022 1.0 Reference and Address Email Page 2 of 138 DRAWING NUMBER:SS BLUE RAVEN SOLAR Report No. 102393982LAX-002 Unirac, Inc Page 3 of 138 Issued: 11-Apr-2016 Revised: 5-Oct-2022 Product Brand name 2.0 Product Description Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 Unirac Description The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report. There are no rails within this product, whereas the 3" Micro Rail, Floating Splice, and 9" Attached Splice electrically bond the modules together forming the path to ground. The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate the anodized coating of the photovoltaic module frame (at bottom flange) to contact the metal, creating a bonded connection from module to module. The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the revision in effect in the jurisdiction in which the project resides. Any local electrical codes must be adhered in addition to the national electrical codes. The Grounding Lug is secured to the photovoltaic module, torqued in accordance with the installation manual provided in this document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same engage cable. ED 16.3.15 (1-Jul-2022) Mandatory Report No. 102393982LAX-002 Unirac, Inc Page 4 of 138 Issued: 11-Apr-2016 Revised: 5-Oct-2022 2.0 Product Description Models Model Similarity Other Ratings Ratings Fuse Rating: 30A Module Orientation: Portrait or Landscape Maximum Module Size: 17.98 ft² UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope Tested Loads - 50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading Increased size ML test: Maximum Module Size: 22.3 ft² UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope LG355S2W-A5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope LG395N2W-A5, LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" IEC 61646 Test Loads - 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift Mechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 Certifications, & Increase SFM System UL2703 Module Size: Maximum Module Size: 27.76 ft² UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-Slope Jinko Eagle 72HM G5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Mamzimum module size: 21.86 ft2 IEC 61646 Test Loads - 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift SunPower model SPR-A430-COM-MLSD used for Mechanical Loading Fire Class Resistance Rating: - Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5” gap between the bottom of the module and the roof’s surface See section 7.0 illustractions # 1, 1a and 1b for a complete list of PV modules evaluated with these racking systems Unirac SFM NA NA ED 16.3.15 (1-Jul-2022) Mandatory