Loading...
Norcross, Christopher - PV PlansTHIS PROJECT COMPLIES WITH THE FOLLOWING: 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) 2018 INTERNATIONAL MECHANICAL CODE (IMC) 2018 INTERNATIONAL PLUMBING CODE (IPC) 2018 INTERNATIONAL FUEL GAS CODE (IFGC) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) 2020 NATIONAL ELECTRICAL CODE (NEC) AS ADOPTED BY CITY OF YELM CODES: VICINITY MAP: TABLE OF CONTENTS: CONSTRUCTION NOTES: ROOF MOUNT PHOTOVOLTAIC SYSTEM PV-1 SITE LOCATION PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-2B ARRAY AND STRUCTURAL TABLES PV-3 MOUNTING DETAILS PV-4 THREE LINE DIAGRAM PV-5 CONDUCTOR CALCULATIONS PV-6 EQUIPMENT & SERVICE LIST PV-7 LABELS PV-7A SITE PLACARD PV-8 MICROINVERTER CHART PV-9 SAFETY PLAN PV-10 SAFETY PLAN APPENDIX MANUFACTURER SPECIFICATION SHEETS CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED. MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2020 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. PV-1 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - GREG ALBRIGHT SITE LOCATION THIS SYSTEM DESIGNED WITH: WIND SPEED: 98 WIND EXPOSURE: B SNOW LOAD: 15 JB MSP ACCB UM DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC SITE PLAN SCALE: 2/25" = 1'-0"1 ROOF LINE PROPERTY LINE DRIVEWAY (E) MAIN SERVICE PANEL (N) 14 FREEDOM FOREVER: FF-MP-BBB-400 (E) UTILITY METER (N) JUNCTION BOX TOTAL ROOF AREA RIDGE SETBACK CALCS: TOTAL ROOF AREA: 1760.33 SQ FT SINGLE MODULE AREA: 21.01937947 SQ FT TOTAL NUMBER OF MODULES: 14 TOTAL AREA OF MODULES: 294.27 SQ FT ROOF COVERAGE: 16.72% FIRE SPRINKLERS : NO PV SYSTEM 5.600 kW-DC 4.060 kW-AC (N) ENPHASE IQ8PLUS-72-2-US MICROINVERTER (N) VISIBLE LOCKABLE LABELED DISCONNECT EATON DG221URB (OR EQUIVALENT) PV-2 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - THIS SYSTEM DESIGNED WITH: WIND SPEED: 98 WIND EXPOSURE: B SNOW LOAD: 15 ROOF AREA: 1760.33 SQ FT SITE PLAN LEGEND: CHIMNEY PIPE VENT ATTACHMENTS MODULES RAFTERS RAIL SETBACK MSP AC AC DISCONNECT MSP JUNCTION BOX PRODUCTION METER DC / AC MICRO INVERTER PM JB CP COMBINER PANEL DO T S O N S T R E E T S O U T H E A S T GREG ALBRIGHT 100'-10" 57 ' - 4 " 100'-10" 57 ' - 4 " 23'-10" 19 ' - 1 " 19'-9" 4' - 8 " (N) ENPHASE COMBINER BOX JB MSP ACCB UM DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC PV-2A FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - ROOF PLAN SCALE: 1/8" = 1'-0"1 MODIFIED SETBACKS PROPOSED AT RIDGE: TOTAL ARRAY AREA = 294.27 SF TOTAL ROOF AREA = 1760.33 SF TOTAL ARRAY AREA AS A % TO ROOF AREA = 16.72% 16.72% < 33% PV SYSTEM 5.600 kW-DC 4.060 kW-AC NOTES: 1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES 3.JUNCTION BOX IS MOUNTED TO THE RAIL. ROOF AREA: 1760.33 SQ FT THIS SYSTEM DESIGNED WITH: WIND SPEED: 98 WIND EXPOSURE: B SNOW LOAD: 15 ROOF PLAN WITH MODULES LAYOUT LEGEND: CHIMNEY PIPE VENT ATTACHMENTS MODULES RAFTERS RAIL SETBACK MSP AC AC DISCONNECT MSP JUNCTION BOX PRODUCTION METER DC / AC MICRO INVERTER PM JB CP COMBINER PANEL TOTAL ROOF AREA: 1760.33 SQ FT TOTAL ARRAY AREA: 294.27 SQ FT ARRAY COVERAGE: 16.72% SYSTEM DISTRIBUTED WEIGHT: 2.32 LBS ROCKIT SMART SLIDE POINT-LOAD: 27.28 LBS GREG ALBRIGHT ROOF LINE (E) MAIN SERVICE PANEL (N) 14 FREEDOM FOREVER: FF-MP-BBB-400 (E) UTILITY METER (N) JUNCTION BOX (N) ENPHASE IQ8PLUS-72-2-US MICROINVERTER (N) VISIBLE LOCKABLE LABELED DISCONNECT EATON DG221URB (OR EQUIVALENT) (N) ENPHASE COMBINER BOX 3' - 0 " 3'-0" 3' - 0 " 3'-0" 3'-0" 3'-0" FIRE ACCESS PATHWAYS FIRE ACCESS PATHWAYS PV-2B FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - ARRAY DETAILS ROOF AREA STATEMENT ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA ROOF 1 14 25 25 269.67 762.01 SQ FT 294.27 SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT ROOF DETAILS: TOTAL ROOF AREA: 1760.33 SQ FT TOTAL ARRAY AREA: 294.27 SQFT ARRAY COVERAGE: 16.72% SYSTEM DISTRIBUTED WEIGHT: 2.32 LBS ROCKIT SMART SLIDE POINT-LOAD: 27.28 LBS GREG ALBRIGHT ROCKIT MOUNT ROOF SURFACE SKIRT ROCKIT MOUNT ROOF MEMBRANE PV MODULE ROCKIT MOUNT ROOF MEMBRANE 2" MIN. EMBED. 2" MIN. EMBED. 2 x #12 WOOD SCREW WITH 2" MIN. EMBEDMENT AND FLAT WASHER 2 x #12 WOOD SCREW WITH 2" MIN. EMBEDMENT AND FLAT WASHER 2 x #12 WOOD SCREW WITH 2" MIN. EMBEDMENT AND FLAT WASHER 2" MIN. E M B E D . ROCKIT RAIL-LESS PV MODULE 3 " M I N . (E)2X4 TRUSS @ 24" O.C. TABLE 1 - ARRAY INSTALLATION ROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE MAX UNBRACED LENGTH(FT.) STRUCTURAL ANALYSIS RESULT PENETRATION PATTERN MAX ATTACHMENT SPACING (IN.) MAX RAIL OVERHANG(I N.) ROOF 1 25 Comp Shingle Ecofasten RockIt Smart Slide 2x4 TRUSS @ 24" O.C.8 PASS STAGGERED 72" O.C.24" 1. CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION. IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS, NOTIFY ENGINEER OF RECORD IMMEDIATELY. 2. WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST, CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS. 3. MAX RAIL OVERHANG APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS. ATTACHMENT DETAIL Scale: NTS SOLAR PV ARRAY SECTION VIEW Scale: NTS PV-3 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - MOUNTING DETAILS STAGGERED DETAIL For Illustration purposes only STACKED DETAIL For Illustration purposes only GREG ALBRIGHT 4 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" EMT CONDUIT JUNCTION BOX NEMA 3R INVSTRING-2 7 FREEDOM FOREVER: FF-MP-BBB-400 BRANCH CABLES INTEGRAL TO INVERTERS 1 #6 AWG, BARE COPPER GROUND ENPHASE IQ8PLUS-72-2-US MICROINVERTERS INVSTRING-1 7 FREEDOM FOREVER: FF-MP-BBB-400 ENPHASE IQ8PLUS-72-2-US MICROINVERTERS BRANCH CABLES INTEGRAL TO INVERTERS 1 #6 AWG, BARE COPPER GROUND UM(E) 200A / 2P MAIN BREAKER (TOP FED) (E) 200A RATED MAIN SERVICE PANEL 1PH, 120/240V 60HZ (E) UTILITY METER (N) 25A / 2P PV BREAKER TO OTHER LOADS TO UTILITY UNDERGROUND FEED 3 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) 30A RATED VISIBLE LOCKABLE LABELED DISCONNECT EATON DG221URB (OR EQUIVALENT) KNIFEBLADE, LOCKABLE, NEMA 3R, UL LISTED 3 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) ENPHASE COMBINER BOX (N) 20A / 2P (N) 20A / 2P (N) 15A / 2P IQ GATEWAY NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS BACKFEED BREAKER SIZING MAX. CONTINUOUS OUTPUT 16.94A @ 240V 16.94 X 1.25 =21.18AMPS 25A BREAKER - OK SEE 705.12 OF 2020 NEC 200 X 1.20 =240 240 -200 =40A ALLOWABLE BACKFEED PV SYSTEM 5.600 kW-DC 4.060 kW-AC PV-4 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - THREE LINE DIAGRAM GREG ALBRIGHT PV-5 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - CONDUCTOR CALCULATIONS GREG ALBRIGHT WIRE SCHEDULE RACEWAY #EQUIPMENT CONDUCTOR QTY. AWG WIRE SIZE STARTING ALLOWABLE AMPACITY @ 90°C 310.15(B)(16) STARTING CURRENT APPLIED TO CONDUCTORS IN RACEWAY TEMPERATURE CORRECTION FACTOR 310.15(B)(2)(a) ADJUSTMENT FACTOR FOR MORE THAN 3 CONDUCTORS 310.15(B)(3)(a) ADJUSTED CONDUCTOR AMPACITY @ 90°C MAXIMUM CURRENT APPLIED TO CONDUCTORS IN RACEWAY 1 DC MODULE TO MICROINVERTER 2 10 40 17.24 1 1 40.00 21.55 2 AC MICROINVERTER TO JUNCTION BOX 2 10 40 8.47 1 1 40.00 10.59 3 AC JUNCTION BOX TO ENPHASE COMBINER PANEL 4 10 40 8.47 1 0.8 32.00 10.59 4 AC ENPHASE COMBINER PANEL TO AC DISCONNECT 3 10 40 16.94 1 1 40.00 21.18 5 AC AC DISCONNECT TO POI 3 10 40 16.94 1 1 40.00 21.18 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST: PV-6 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - QTY.PART PART #DESCRIPTION 14 MODULES PV-110-400 FREEDOM FOREVER: FF-MP-BBB-400 1 JUNCTION BOX RAC-260-049 600VDC NEMA 3R UL LISTED JUNCTION BOX 1 MOUNTING BRACKET RAC-211-201 UNIRAC E-BOSS J-BOX MOUNTING BRACKET 4 ELECTRICAL ACCESSORIES EA-350-326 STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE) 4 EQUIPMENT ACCESSORIES EA-350-327 STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE) 14 INVERTERS INV-120-015 ENPHASE IQ8PLUS-72-2-US 1 MONITORING EQUIPMENT ME-180-201-4C ENPHASE: COMBINER PANEL 4C 17 ELECTRICAL ACCESSORIES EA-160-106 "ENPHASE, Q CABLE PORTRAIT FOR 60/72 CELL" 17 ELECTRICAL ACCESSORIES EA-160-105 "ENPHASE, Q CABLE LANDSCAPE 60 CELL" 1 MONITORING EQUIPMENT ME-180-201 "ENPHASE, AC COMBINER W/ IQ GATEWAY PCBA, 80A, 240V" 1 WIRE WR-310-300 "ENPHASE, RAW TRUCK CABLE (300 FT. ROLL)" 112 ELECTRICAL ACCESSORIES EA-160-110 ENPHASE TIE WRAPS / CABLE CLIPS 4 ELECTRICAL ACCESSORIES EA-160-107 ENPHASE SEALING CAPS FOR Q CABLE 2 ELECTRICAL ACCESSORIES EA-160-109 ENPHASE TERMINATOR 1 DISCONNECTS EE-321-030 30A RATED 240VAC NEMA 3R UL LISTED 25 FITTINGS/ANCHORS RAC-265-034 ROCKIT SMART SLIDE 27 FOOTINGS RAC-265-004 "MFG: ECO FASTEN, ROCKIT COMP COUPLING AL BLK, MFG SKU: 2011021" 25 FOOTINGS RAC-265-001 "MFG: ECO FASTEN, GF-1 FLASHING GLV BLK 8X10"", MFG SKU: 3012020" FOOTINGS RAC-265-028 "MFG: ECO FASTEN, SKIRT AL BLK 35MM & 40MM A80, MFG SKU: 2099012" FITTINGS/ANCHORS RAC-265-031 "MFG: ECO FASTEN, SKIRT END CAP PLS 35MM&40MM-A, MFG SKU: 2099035" 14 RAILS RAC-265-018 "MFG: ECO FASTEN, FRAME MLPE MOUNT SS, MFG SKU: 4011012" 50 SCREW RAC-265-035 ROCKIT SCREW #12X3 OCPD SIZES: 25A BREAKER SERVICE LIST: NONE EQUIPMENT & SERVICE LIST GREG ALBRIGHT NOTES: M690.13(B) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY IFC 605.11.3.1(1) & 690.56(C) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AC NEC 690.13(B) EVERY 10' ON CONDUIT AND ENCLOSURES SOLAR ELECTRIC PV PANELS 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 110.27(C) & OSHA 1910.145(F)(7) !WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL !WARNING SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUITS NEC 710.15(C) & 692.9 (C) NEC 690.15 (B) & NEC 690.33(D)(2) DO NOT DISCONNECT UNDER LOAD NEC 705.12(D) & NEC 690.59 !CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED NEC 705.12(D) & NEC 690.59 NEC 705.12(C) & NEC 690.59 !WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM !WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. !WARNING ARC FLASH AND SHOCK HAZARD APPROPRIATE PPE REQUIRED 24 INCH 3 480 VAC 42 INCH 12 INCH 1 INCH FLASH HAZARD BOUNDARY CAL/CM^2 FLASH HAZARD AT 18 INCHES SHOCK HAZARD WHEN COVER IS REMOVED LIMITED APPROACH RESTRICTED APPROACH - 500 V CLASS 00 GLOVES PROHIBITED APPROACH - 500 V CLASS 00 GLOVES LOCATION:9936 DOTSON STREET SOUTHEAST,YELM, WA 98597 PHOTOVOLTAIC AC DISCONNECT PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 16.94A 240V!WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR NEC 690.54 NEC 705.12(B)(3)(3) NEC 706.15(C) AND NEC 110.16 !WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT NEC 690.31(E) PHOTOVOLTAIC POWER SOURCE NEC 690.31(D)(2) J/B NEC 690.31(G)(3) & (4) 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 110.27(C) & OSHA 1910.145(F)(7) !WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(3)MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX DC-DC CONVERTER OUTPUT CURRENT V A A N/A 60 15OPTIONAL SOLAR LOAD CENTER ARRAY PV-7 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - LABELS GREG ALBRIGHT 1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2.ALL MARKING SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C.ARIAL FONT. 3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS 14 PV MODULES CAUTION: PV-7A FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - 1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2.ALL MARKING SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C.AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. NOTES: SITE PLACARD GREG ALBRIGHT WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL N DO T S O N S T R E E T S O U T H E A S T POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN UTILITY METER MAIN SERVICE PANEL AC DISCONNECT INVERTER EQUIPPED WITH RAPID SHUTDOWN JUNCTION BOX JB MSP ACCB UM PV-8 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - ENPHASE MICROINVERTER CHART MICROINVERTER CHART GREG ALBRIGHT 1 1-20 21-40 41-60 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 JB MSP ACCB UM DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC PV-9 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - SAFETY PLAN GREG ALBRIGHT SAFETY PLAN MARK UP KEY INSTRUCTIONS: 1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET. 2.SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN 3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ON THE JHA SHEET INCIDENT REPORTING: INJURIES - CALL INJURY HOTLINE (855) 400-7233 *If injury is life threatening, call 911 first THEN the Injury Hotline NON-INJURIES - USE MOBILE INCIDENT REPORTING (Auto, Property Damage, Near Miss) NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC: NAME: _______________________________________________ ADDRESS: ___________________________________________ NEAREST HOSPITAL: NAME:_______________________________________________ ADDRESS: ___________________________________________ SAFETY COACH CONTACT INFORMATION: NAME: _______________________________________________ PHONE NUMBER: _____________________________________ ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. NAME SIGNATURE __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ DATE: ______________ TIME:___________________________ PERMANENT ANCHOR TEMPORARY ANCHOR INSTALLER LADDER JUNCTION / COMBINER BOX STUB-OUT SKYLIGHT NO LADDER ACCESS (STEEP GRADE OR GROUND LEVEL OBSTRUCTIONS) RESTRICTED ACCESS CONDUIT GAS SHUT OFF WATER SHUT OFF SERVICE DROP POWER LINES P T IL B S 7 Z GAS H2O BREAK AND WATER LOG THIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS IS COMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREES NAME 0800HRS 0900HRS 1000HRS 1100HRS 1200HRS 1300HRS 1400HRS 1500HRS 1600HRS POLICIES INSTRUCTIONS: 1.SCAN QR LINK BELOW TO ACCESS ALL FREEDOM FOREVER SAFETY POLICIES AND PROGRAMS. JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access ·Ladders must be inspected before each use. ·Extension ladders must be set up on a firm and level surface at a 4-to-1 rise to run angle (or 75 degrees) and the top must be secured to the structure. Extension style ladders placed on uneven, loose or slippery surfaces must additionally have the base firmly anchored or lashed so the base will not slip out. ·Extension ladders must be used with walk-through devices or the ladder must extend 36" above the stepping off point. ·A-frame ladders must only be climbed with the ladder spreader bars locked in the open position; A-frame ladders shall not be climbed while in the closed position (ex, closed and used while leaned against a structure). ·Additional notes: Mobile Equipment ·Only Qualified operators will operate equipment; operators must maintain a certification on their person for the equipment being operated. ·Type(s) of mobile equipment (Type/Make/Model): ·Qualified operator(s): Material Handling and Storage ·Materials will be staged/stored in a way that does not present a hazard to client, personnel or public. Materials stored on the roof will be physically protect from failing or sliding off. Fall Protection ·A site-specific plan for fall prevention and protection is required prior to starting work and must remain onsite at all times until work is complete; a fall rescue plan must be outlined and discussed among the crew prior to work start. ·First-person-Up (FPU) must install their anchor and connect before any other task, including installing other anchors. The Last-Person-Down (LPD) must be the only person on a roof uninstalling fall protection. ·FPCP (name and title): ·FPU and LPD (name and title): Electrical Safety ·The Electrical Qualified Person (EQP) is required onsite to perform electrical work. ·All electrical work will be performed with equipment in an electrically safe condition (de-energized) unless approval has been granted prior to work. ·Service drops and overhead electrical hazards will be indentified and protected from contact, as neccessary. ·EQP (name and tile): Public Protection ·The safety of the Client and Public must be maintained at all times. ·The Client and the Public shall be prevented from entering the work zone through the use of barriers and/or signage, as required. ·Company, Client and Public property shall be protected from falling objects. ·Pets (including dogs) shall be secured by their owners prior to work start. ·The Client should not leave pets, family members, or others in charge or care of Employees, Contractors, or Temporary Workers. ·Crew leader responsible for communication with the client: ·Client and public is excluded from work area by barricades (N/A, Yes, No): Training and Pre-Job Safety Briefing ·All employees onsite shall be made aware of the specific hazards of this project and review this HJA during a pre-job briefing, and their signature indicates awareness of site conditions and the plan to eliminate any hazards identified prior to and during the project. ·Crew leader (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): Airborne Contaminants: ·Asbestos-containing (Transite) piping (ACP) - Do not disturb (move, drill, cut fracture, etc.) ·Asbestos-containing thermal insulation (ACI) and Asbestos-containing duct wrapping (ACW) - do not disturb, no attic or crawlspace access is allowed if work to be performed could cause exposure to personnel, client or public. ·If yes, list specific tasks and protection in place: Weather and Environment ·The site supervisor shall forecast the weather conditions at the job site, prior to crew arrival, in order to mitigate any hazards associated with inclement weather (heat, cold, wind, rain, etc.) ·The site supervisor will utilized a portable wind meter (anemometer) to verify actual onsite wind conditions, by checking at the ground and on any elevated work surface (ex, rooftop) prior to work start, at midday and prior to solar panel staging on a roof. ·Elevated work involving the moving or maneuvering of solar panels shall cease at 25mph (sustained wind) until wind subsides. ·Forecasted weather maximum temp (degrees f): Heat Related Illness Prevention ·Employees shall have access to potable drinking water that is fresh, pure, and suitably cool. The water shall be located as close as practicable to the areas where employees are working. Water shall be supplied in sufficient quantity at the beginning of the work shift to provide at least one quart per employee per hour for drinking for the entire shift. Employees may begin the shift with smaller quantities of water if they identify the location and have effective means for replenishment during the shift to allow employees to drink on quart or more per hour. The frequent drinking of water shall be encouraged. ·Shade shall be present when temperature exceeds 80 degrees Fahrenheit. When the outdoor temperature in the work exceeds 80 degrees Fahrenheit, employees shall have and maintain one or more areas with shade at all times. ·New employees must be acclimatized. New employees will be monitored by their Crew Leader (site supervisor) for the first two (2) weeks of employment or longer when necessary. ·Employees will be allowed and encouraged to implement scheduled breaks during each shift. Employees must take cool-down breaks in the shade any time they feel the need to do so to protect them from overheating. Supervisors are REQUIRED to allow employees any break period they need during high heat conditions. ·Cool Vests are encouraged for all employees at all times during periods of high heat. ·Identify the location of the closet Occupational/Industrial Clinic or Hospital in case a crew member becomes ill. What is the specific plan to provide and replenish sufficient water for all employees on site? ·If offsite replenish is necessary, where will you go to replenish water (location/address): ·Who will replenish the drinking water (name): Restroom facilities ·Employees shall have access to restroom facilities with hand-washing stations. Use of onsite restroom is at the client's discretion (location is annotated below). If client does not give permission, location of suitable restroom facilities with hand-washing stations offsite will be provided. The onsite supervisor will identify location and make arrangements to ensure all employees have access at any point. ·Restroom facilities will be (circle one): Onsite - Offsite ·If Offsite, add location name and address: Incident Reporting Procedure ·Contact your Site Supervisor Name: Phone: ·Contact your Manager Name: Phone: ·Contact your Site Supervisor Name: Phone: With: Your full name, phone number, office location, brief description of what happen and when. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE (add as many as necessary by using additional sheets) Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: PV-10 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407301 DESIGNED BY: F.S. CLIENT: CHRISTOPHER NORCROSS 9936 DOTSON STREET SOUTHEAST, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 163571514 APN: 7864-01-13200 PHONE: (210) 823-0575 EMAIL: CJN08C@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 14 X 400 = 5.600 kW SYSTEM SIZE (AC): 4.060 kW @ 240V MODULES: 14 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 14 X ENPHASE IQ8PLUS-72-2-US DATE: 2/10/2024 -- -- -- - - - SAFETY PLAN GREG ALBRIGHT SCAN QR CODE TO  ACCESS REFERENCE LINK PV INSTALLATION REFERENCESFREEDOM REFERENCES BATTERY INSTALLATION REFERENCES ENPHASE SOLAREDGE TESLAINSTALL HOTLINE TESLA Storage Systems NON‐BACKUP Battery SystemsSOLAREDGE Storage SystemsEnphase Storage Systems Misc. Quick Guide FOR INSTALLATION REFERENCE ONLY V1.4 Pe r f o r m a n c e F i g u r e s i n % MECHANICAL LOADING MODULE SPECIFICATIONS 17 2 2 ± 2 17 2 2 . 0 M M 13 1 6 . 0 M M 22 7 . 2 M M TEMPERATURE RATINGS PACKAGING INFORMATION MECHANICAL CHARACTERISTICS OPERATIONS CHARACTERISTICS 35 [ 1 . 3 8 ] UL 61730 | UL 61215 | ISO 9001 | ISO 14001 ELECTRICAL CHARACTERISTICS for L. Matthew Snyder, Certification Manager DATA SHEET IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Easy to install • Lightweight and compact with plug-n- play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB 3rd Ed.) Note: IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, etc) in the same system. © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. *Only when installed with IQ System Controller 2, meets UL 1741. **IQ8 and IQ8Plus support split-phase, 240V installations only. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL listed as PV Rapid Shutdown Equipment and conform with various regulations, when installed according to manufacturer’s instructions. IQ8SP-12A-DS-0067-03-EN-US-2022-12-27 (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at https://link.enphase.com/module-compatibility. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8 and IQ8+ Microinverters INPUT DATA (DC) IQ8-60-2-US IQ8PLUS-72-2-US Commonly used module pairings1 W 235 – 350 235 – 440 Module compatibility 60-cell / 120 half-cell 54-cell / 108 half-cell, 60-cell / 120 half-cell, 66-cell / 132 half- cell and 72-cell / 144 half-cell MPPT voltage range V 27 – 37 27 – 45 Operating range V 16 – 48 16 – 58 Min. / Max. start voltage V 22 / 48 22 / 58 Max. input DC voltage V 50 60 Max. continuous input DC current A 10 12 Max. input DC short-circuit current A 25 Max. module Isc A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ8-60-2-US IQ8PLUS-72-2-US Peak output power VA 245 300 Max. continuous output power VA 240 290 Nominal (L-L) voltage / range2 V 240 / 211 – 264 Max. continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 47 – 68 AC short circuit fault current over 3 cycles Arms 2 Max. units per 20 A (L-L) branch circuit3 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable) 0.85 leading – 0.85 lagging Peak efficiency %97.7 CEC weighted efficiency %97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to +60°C (-40°F to +140°F) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (H x W x D) 212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB 3rd Ed.), FCC Part 15 Class B, ICES-0003 Class B, CAN / CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8SP-12A-DS-0067-03-EN-US-2022-12-27 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) The IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. IQ Combiner 4/4C To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Gateway for communication and control • Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery EIWXLIXMGWERHHIƥIGXLIEX • Supports Wi-Fi, Ethernet, or cellular connectivity • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Mounts on single stud with centered brackets • Supports bottom, back and side conduit entry • Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable ŵ (YVEFPI2680GIVXMƤIH2)1%X]TI6IRGPSWYVI • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's •UL listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with -))) 907&rd Ed.) X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) Q-AM1-240-4C Q AM1 2404C (IEEE 1547 2 M1-240-4 2018)2018) -5''(7)297© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. MODEL NUMBER IQ Combiner 4 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to HIƥIGXLIEX IQ Combiner 4C X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the -5&EXXIV]ERH-57]WXIQ'SRXVSPPIVERHXSHIƥIGXLIEX ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IQ8) Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B 7YTTSVXW)EXSR&6&6&6&6&6&6ERH&6GMVGYMXFVIEOIVW Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C <%409+Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws Consumption monitoring CT (CT-200-SPLIT/CT-200-CLAMP) A pair of 200A split core current transformers ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240VAC, 60 Hz Eaton BR series busbar rating 125A Max. continuous current rating 65A Max. continuous current rating (input from PV/storage) 64A Max. fuse/circuit rating (output)% Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input)%SJHMWXVMFYXIHKIRIVEXMSR%[MXL-5+EXI[E]FVIEOIVMRGPYHIH IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre-installed and wired to IQ Gateway MECHANICAL DATA Dimensions (WxHxD)GQ\GQ\GQ MR\MR\MR ,IMKLXMWGQ MR [MXLQSYRXMRKFVEGOIXW Weight 7.5 kg (16.5 lbs) Ambient temperature range -40ºC to +46ºC (-40ºF to 115ºF) Cooling Natural convection, plus heat shield Enclosure environmental rating 3YXHSSV2680GIVXMƤIH2)1%X]TI6TSP]GEVFSREXIGSRWXVYGXMSR Wire sizes • 20A to 50A breaker inputs: 14 to 4 AWG copper conductors • 60A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors • Always follow local code requirements for conductor sizing. Altitude 9TXSQIXIVW JIIX INTERNET CONNECTION OPTIONS Integrated Wi-Fi IEEE 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Mobile Connect cellular modem is required for all Enphase Energy System installations. Ethernet 3TXMSREP-)))'EX) SV'EX 984)XLIVRIXGEFPI RSXMRGPYHIH COMPLIANCE Compliance, IQ Combiner CA Rule 21 (UL 1741-SA) -)))907&rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) '%2'7%'2S8MXPI'*64EVX'PEWW&-')7 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 IQ Combiner 4/4C -5''(7)297 Product specifications Eaton DG221URB Catalog Number: DG221URB Eaton General duty non-fusible safety switch, single-throw, 30 A, 240 V, NEMA 3R, Rainproof, Painted galvanized steel, Two-pole, Two-wire General specifications Eaton general duty non-fusible safety switch DG221URB 782113120232 6.88 in 10.81 in 6.38 in 6 lb Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. UL Listed WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Product Name Catalog Number UPC Product Length/Depth Product Height Product Width Product Weight Warranty Certifications Catalog Notes Eaton Corporation plc Eaton House 30 Pembroke Road Dublin 4, Ireland Eaton.com © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are property of their respective owners.Eaton.com/socialmedia Product specifications General duty safety switch Painted galvanized steel Non-fusible, single-throw Non-fusible 2 NEMA 3R 240V 30A Two-pole Resources Eaton's Volume 2—Commercial Distribution Double Up on Safety Switching Devices Flex Center Eaton Specification Sheet - DG221URB Product Category Enclosure material Type Fuse configuration Number of wires Enclosure Voltage rating Amperage Rating Number Of Poles Catalogs Multimedia Specifications and datasheets RaCKIT INTRODUCING ROCKIT SMART SLIDE! Introducing EcoFasten's patent pending Rocklt Smart Slide, our simple solution for quickly installing the popular Rocklt rail -less racking system to composition shingle roofs. Features & Benefits • Eliminates the need to pry up shingle courses and install a metal flashing • Multiple opportunities to find the rafter • No need for additional material when architectural shingles are not level • Longer 6.75" slide avoids overlaps in shingle courses • Integrated flashing utilizes UltraGrip TechnologyTM to create a watertight seal Required Components: 2011024 RI SMART SLIDE BLK 6.75" 2011025 RI SMART SCRW #12X3" W/BW D���444 D.IVIS/p4, APp�O.,,* V V C FL#39871 G ? D ND d �'s STATE OF DDvvvaa ROCKIT SMART SLIDE Integrated UltraGrip TechnologyTM Pre -installed sealing pads are compatible with all composition shingle roofs. The compression achieved when fastened to the roof creates a super strong watertight seal. In most cases, the slide can be mounted to the deck without the need for sealant. A layer of flexible foam provides cushioning, which allows the waterproofing sealant to embed deep into the granules of the shingle as well as to flexibly conform over the steps found on architectural -style shingles. Testing & Documentation LIDE • UL441 Rain Report • TAS 100 (A)-95 Wind and Wind Driven Rain Resistance • Mechanical Load Test/Structural Capacity Certification • Florida Product Approval • Rocklt Installation Manual • Rocklt CutSheets VI EcoFQstena 4141 W. VAN BUREN ST, SUITE 2, PHOENIX Az 85009 An Esdec Solar Group Company 1- 8 7 7- 8 5 9- 3 9 4 7 1 INFO @ E C O F A S T E N S O L A R. C OM          ;          5,60$576/,'(%/.  52&.,7)/$6+/(666/,'($66(0%/< $'+(6,9(5(/($6(/,1(5 ,7(012'(6&5,37,21 52&.,760$576/,'($66(0%/< 3$57180%(5 '(6&5,37,21 5,60$576/,'(%/. 0$7(5,$/$/80,180(3'0$'+(6,9(75($7('3$3(5 ),1,6+%/$&.5HY&6 1 .31 7.8 2.87 72.8 3.00 76.2 .55 14.0 .42 10.5 RI SMART SCREW #12X3" W/BW PART NUMBER DESCRIPTION 2011025 RI SMART SCREW #12X3" W/BW ITEM NO.DESCRIPTION 1 SELF TAPPING SCREW #12 WITH SEALING WASHER ASSEMBLY MATERIAL STAINLESS STEEL, EPDM RUBBER FINISH MILL, BLACK Rev: CS-2