Spjut, Walter - PV PlansTHIS PROJECT COMPLIES WITH THE FOLLOWING: 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) 2018 INTERNATIONAL MECHANICAL CODE (IMC) 2018 INTERNATIONAL PLUMBING CODE (IPC) 2018 INTERNATIONAL FUEL GAS CODE (IFGC) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) 2020 NATIONAL ELECTRICAL CODE (NEC) AS ADOPTED BY CITY OF YELM CODES: VICINITY MAP: TABLE OF CONTENTS: CONSTRUCTION NOTES: ROOF MOUNT PHOTOVOLTAIC SYSTEM PV-1 SITE LOCATION PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-2B ARRAY AND STRUCTURAL TABLES PV-3 MOUNTING DETAILS PV-4 THREE LINE DIAGRAM PV-5 CONDUCTOR CALCULATIONS PV-6 EQUIPMENT & SERVICE LIST PV-7 LABELS PV-7A SITE PLACARD PV-8 MICROINVERTER CHART PV-9 SAFETY PLAN PV-10 SAFETY PLAN APPENDIX MANUFACTURER SPECIFICATION SHEETS CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED. MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2020 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. PV-1 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - GREG ALBRIGHT SITE LOCATION J B MSP AC CB UM SU B DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC SITE PLAN SCALE: 3/32" = 1'-0"1 ROOF LINE PROPERTY LINE DR I V E W A Y FENCE/GATE (E) MAIN SERVICE PANEL (N) 13 FREEDOM FOREVER: FF-MP-BBB-400 (E) UTILITY METER TOTAL ROOF AREA RIDGE SETBACK CALCS: TOTAL ROOF AREA: 1031.79 SQ FT SINGLE MODULE AREA: 21.01937947 SQ FT TOTAL NUMBER OF MODULES: 13 TOTAL AREA OF MODULES: 273.25 SQ FT ROOF COVERAGE: 26.48% FIRE SPRINKLERS : NO PV SYSTEM 5.200 kW-DC 3.770 kW-AC (N) SUB PANEL (N) ENPHASE IQ8PLUS-72-2-US INVERTER WITH RAPID SHUTDOWN (N) VISIBLE LOCKABLE LABELED DISCONNECT EATON DG221URB (OR EQUIVALENT) PV-2 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - THIS SYSTEM DESIGNED WITH: WIND SPEED: 98 WIND EXPOSURE: B SNOW LOAD: 15 ROOF AREA: 1031.79 SQ FT SITE PLAN LEGEND: CHIMNEY PIPE VENT MODULES CONDUIT SETBACK AC DISCONNECT UTILITY METER JUNCTION BOX SUBPANEL MAIN SERVICE PANEL AC UM JB SUB MSP M C K E N Z I E A V E S W GREG ALBRIGHT 103 ' - 0 " 5 0 ' - 1 1 " 103 ' - 0 " 5 0 ' - 1 1 " 8' - 2 " 38' - 1 0 " 7' - 9 " 36' - 0 " (N) ENPHASE COMBINER BOX (N) JUNCTION BOX J B MS P AC CB UM SU B DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC PV-2A FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - ROOF PLAN SCALE: 1/8" = 1'-0"1 MODIFIED SETBACKS PROPOSED AT RIDGE: TOTAL ARRAY AREA = 273.25 SF TOTAL ROOF AREA = 1031.79 SF TOTAL ARRAY AREA AS A % TO ROOF AREA = 26.48% 26.48% < 33% (N) 13 FREEDOM FOREVER: FF-MP-BBB-400 PV SYSTEM 5.200 kW-DC 3.770 kW-AC NOTES: 1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES 3.JUNCTION BOX IS MOUNTED TO THE RAIL. ROOF AREA: 1031.79 SQ FT THIS SYSTEM DESIGNED WITH: WIND SPEED: 98 WIND EXPOSURE: B SNOW LOAD: 15 ROOF PLAN WITH MODULES LAYOUT LEGEND: CHIMNEY PIPE VENT MODULES CONDUIT SETBACK AC DISCONNECT UTILITY METER JUNCTION BOX SUBPANEL MAIN SERVICE PANEL AC UM JB SUB MSP GREG ALBRIGHT (E) MAIN SERVICE PANEL (E) UTILITY METER (N) SUB PANEL (N) ENPHASE IQ8PLUS-72-2-US MICROINVERTER (N) VISIBLE LOCKABLE LABELED DISCONNECT EATON DG221URB (OR EQUIVALENT) (N) ENPHASE COMBINER BOX (N) JUNCTION BOX FIRE ACCESS PATHWAYS FIRE ACCESS PATHWAYS 3' - 0 " 3'-0 " 3' - 0 " 3' - 0 " PV-2B FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - ARRAY DETAILS ROOF AREA STATEMENT ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA ROOF 1 13 20 20 219 496.17 SQ FT 273.25 SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT -------------------- SQ FT SQ FT ROOF DETAILS: TOTAL ROOF AREA: 1031.79 SQ FT TOTAL ARRAY AREA: 273.25 SQFT ARRAY COVERAGE: 26.48% SYSTEM DISTRIBUTED WEIGHT: 2.32 LBS S-5!: PROTEA POINT-LOAD: 11.95 LBS GREG ALBRIGHT PROTEABRACKET PROTEABRACKET (E) TRAPEZOIDAL METAL ROOF PROFILE 1" SELF TAPPING SCREW FACTORY APPLIED EPDM WITH STICKY ADHESIVE (E) TRAPEZOIDAL METAL ROOF PROFILE PV MODULE GROUNDING END/MID CLAMP (E)RAFTER/TOP-CHORD TABLE 1 - ARRAY INSTALLATION ROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE MAX UNBRACED LENGTH(FT.) STRUCTURAL ANALYSIS RESULT PENETRATION PATTERN MAX ATTACHMENT SPACING (IN.) MAX RAIL OVERHANG(IN.) ROOF 1 20 TRAPEZOIDAL METAL S-5 PROTEABRACKET 2X4 TRUSS @ 24" O.C.6.16 PASS STAGGERED 48"OC 16" 1. CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION. IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS, NOTIFY ENGINEER OF RECORD IMMEDIATELY. 2. WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST, CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS. 3. MAX RAIL OVERHANG APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS. ATTACHMENT DETAIL Scale: NTS SOLAR PV ARRAY SECTION VIEW Scale: NTS PV-3 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - MOUNTING DETAILS STAGGERED DETAIL For Illustration purposes only STACKED DETAIL For Illustration purposes only GREG ALBRIGHT 2 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" EMT CONDUIT JUNCTION BOX NEMA 3R INVSTRING-1 13 FREEDOM FOREVER: FF-MP-BBB-400 BRANCH CABLES INTEGRAL TO INVERTERS 1 #6 AWG, BARE COPPER GROUND ENPHASE IQ8PLUS-72-2-US MICROINVERTERS UM(E) 200A / 2P MAIN BREAKER (TOP FED) (N) 60A / 2P SUBPANEL BREAKER (E) 200A RATED MAIN SERVICE PANEL 1PH, 120/240V 60HZ TO UTILITY OVERHEAD FEED (N) 125A MINIMUM RATED SUB PANEL 1PH, 120/240V 60HZ (N) 20A / 2P PV BREAKER (E) UTILITY METER 3 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) 30A RATED VISIBLE LOCKABLE LABELED DISCONNECT EATON DG221URB (OR EQUIVALENT) KNIFEBLADE, LOCKABLE, NEMA 3R, UL LISTED 3 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) ENPHASE COMBINER BOX (N) 15A / 2P IQ GATEWAY (N) 20A / 2P 3 - #6 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 1" OR LARGER EMT CONDUIT NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS BACKFEED BREAKER SIZING MAX. CONTINUOUS OUTPUT 15.73A @ 240V 15.73 X 1.25 =19.66AMPS 20A BREAKER - OK SEE 705.12 OF 2020 NEC 200 X 1.20 =240 240 -200 =40A ALLOWABLE BACKFEED PV SYSTEM 5.200 kW-DC 3.770 kW-AC PV-4 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - THREE LINE DIAGRAM GREG ALBRIGHT PV-5 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - CONDUCTOR CALCULATIONS GREG ALBRIGHT WIRE SCHEDULE RACEWAY #EQUIPMENT CONDUCTOR QTY. AWG WIRE SIZE STARTING ALLOWABLE AMPACITY @ 90°C 310.15(B)(16) STARTING CURRENT APPLIED TO CONDUCTORS IN RACEWAY TEMPERATURE CORRECTION FACTOR 310.15(B)(2)(a) ADJUSTMENT FACTOR FOR MORE THAN 3 CONDUCTORS 310.15(B)(3)(a) ADJUSTED CONDUCTOR AMPACITY @ 90°C MAXIMUM CURRENT APPLIED TO CONDUCTORS IN RACEWAY 1 DC MODULE TO MICROINVERTER 2 10 40 17.24 1 1 40.00 21.55 2 AC MICROINVERTER TO JUNCTION BOX 2 10 40 15.73 1 1 40.00 19.66 3 AC JUNCTION BOX TO ENPHASE COMBINER PANEL 2 10 40 15.73 1 1 40.00 19.66 4 AC ENPHASE COMBINER PANEL TO AC DISCONNECT 3 10 40 15.73 1 1 40.00 19.66 5 AC AC DISCONNECT TO POI 3 10 40 15.73 1 1 40.00 19.66 6 AC SUBPANEL TO MSP 3 6 75 60.00 1 1 75.00 60.00 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST: PV-6 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - QTY.PART PART #DESCRIPTION OCPD SIZES: 20A BREAKER 20A FUSES SERVICE LIST: SUB PANEL INSERT EQUIPMENT & SERVICE LIST GREG ALBRIGHT NOTES: M690.13(B) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY IFC 605.11.3.1(1) & 690.56(C) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AC NEC 690.13(B) EVERY 10' ON CONDUIT AND ENCLOSURES SOLAR ELECTRIC PV PANELS 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 110.27(C) & OSHA 1910.145(F)(7) !WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL !WARNING SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUITS NEC 710.15(C) & 692.9 (C) NEC 690.15 (B) & NEC 690.33(D)(2) DO NOT DISCONNECT UNDER LOAD NEC 705.12(D) & NEC 690.59 !CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED NEC 705.12(D) & NEC 690.59 NEC 705.12(C) & NEC 690.59 !WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM !WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. !WARNING ARC FLASH AND SHOCK HAZARD APPROPRIATE PPE REQUIRED 24 INCH 3 480 VAC 42 INCH 12 INCH 1 INCH FLASH HAZARD BOUNDARY CAL/CM^2 FLASH HAZARD AT 18 INCHES SHOCK HAZARD WHEN COVER IS REMOVED LIMITED APPROACH RESTRICTED APPROACH - 500 V CLASS 00 GLOVES PROHIBITED APPROACH - 500 V CLASS 00 GLOVES LOCATION:408 MCKENZIE AVE SW,YELM, WA 98597 PHOTOVOLTAIC AC DISCONNECT PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 15.73A 240V!WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR NEC 690.54 NEC 705.12(B)(3)(3) NEC 706.15(C) AND NEC 110.16 !WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT NEC 690.31(E) PHOTOVOLTAIC POWER SOURCE NEC 690.31(D)(2) J/B NEC 690.31(G)(3) & (4) 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 110.27(C) & OSHA 1910.145(F)(7) !WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(3)MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX DC-DC CONVERTER OUTPUT CURRENT V A A N/A 60 15OPTIONAL SOLAR LOAD CENTER ARRAY PV-7 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - LABELS GREG ALBRIGHT 1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2.ALL MARKING SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C.ARIAL FONT. 3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS JUNCTION BOX 13 PV MODULES SUBPANEL CAUTION: PV-7A FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - 1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. 2.ALL MARKING SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C.AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. NOTES: SITE PLACARD GREG ALBRIGHT WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL N M C K E N Z I E A V E S W POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN UTILITY METERMAIN SERVICE PANEL AC DISCONNECT COMBINER BOX J B MSP AC CB UM SU B PV-8 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - ENPHASE MICROINVERTER CHART MICROINVERTER CHART GREG ALBRIGHT 1 1-20 21-40 41-60 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 J B MSP AC CB UM SU B DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC PV-9 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - SAFETY PLAN GREG ALBRIGHT SAFETY PLAN MARK UP KEY INSTRUCTIONS: 1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET. 2.SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN 3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ON THE JHA SHEET INCIDENT REPORTING: INJURIES - CALL INJURY HOTLINE (855) 400-7233 *If injury is life threatening, call 911 first THEN the Injury Hotline NON-INJURIES - USE MOBILE INCIDENT REPORTING (Auto, Property Damage, Near Miss) NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC: NAME: _______________________________________________ ADDRESS: ___________________________________________ NEAREST HOSPITAL: NAME:_______________________________________________ ADDRESS: ___________________________________________ SAFETY COACH CONTACT INFORMATION: NAME: _______________________________________________ PHONE NUMBER: _____________________________________ ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. NAME SIGNATURE __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ DATE: ______________ TIME:___________________________ PERMANENT ANCHOR TEMPORARY ANCHOR INSTALLER LADDER JUNCTION / COMBINER BOX STUB-OUT SKYLIGHT NO LADDER ACCESS (STEEP GRADE OR GROUND LEVEL OBSTRUCTIONS) RESTRICTED ACCESS CONDUIT GAS SHUT OFF WATER SHUT OFF SERVICE DROP POWER LINES P T IL B S 7 Z GAS H2O BREAK AND WATER LOG THIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS IS COMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREES NAME 0800HRS 0900HRS 1000HRS 1100HRS 1200HRS 1300HRS 1400HRS 1500HRS 1600HRS POLICIES INSTRUCTIONS: 1.SCAN QR LINK BELOW TO ACCESS ALL FREEDOM FOREVER SAFETY POLICIES AND PROGRAMS. JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access ·Ladders must be inspected before each use. ·Extension ladders must be set up on a firm and level surface at a 4-to-1 rise to run angle (or 75 degrees) and the top must be secured to the structure. Extension style ladders placed on uneven, loose or slippery surfaces must additionally have the base firmly anchored or lashed so the base will not slip out. ·Extension ladders must be used with walk-through devices or the ladder must extend 36" above the stepping off point. ·A-frame ladders must only be climbed with the ladder spreader bars locked in the open position; A-frame ladders shall not be climbed while in the closed position (ex, closed and used while leaned against a structure). ·Additional notes: Mobile Equipment ·Only Qualified operators will operate equipment; operators must maintain a certification on their person for the equipment being operated. ·Type(s) of mobile equipment (Type/Make/Model): ·Qualified operator(s): Material Handling and Storage ·Materials will be staged/stored in a way that does not present a hazard to client, personnel or public. Materials stored on the roof will be physically protect from failing or sliding off. Fall Protection ·A site-specific plan for fall prevention and protection is required prior to starting work and must remain onsite at all times until work is complete; a fall rescue plan must be outlined and discussed among the crew prior to work start. ·First-person-Up (FPU) must install their anchor and connect before any other task, including installing other anchors. The Last-Person-Down (LPD) must be the only person on a roof uninstalling fall protection. ·FPCP (name and title): ·FPU and LPD (name and title): Electrical Safety ·The Electrical Qualified Person (EQP) is required onsite to perform electrical work. ·All electrical work will be performed with equipment in an electrically safe condition (de-energized) unless approval has been granted prior to work. ·Service drops and overhead electrical hazards will be indentified and protected from contact, as neccessary. ·EQP (name and tile): Public Protection ·The safety of the Client and Public must be maintained at all times. ·The Client and the Public shall be prevented from entering the work zone through the use of barriers and/or signage, as required. ·Company, Client and Public property shall be protected from falling objects. ·Pets (including dogs) shall be secured by their owners prior to work start. ·The Client should not leave pets, family members, or others in charge or care of Employees, Contractors, or Temporary Workers. ·Crew leader responsible for communication with the client: ·Client and public is excluded from work area by barricades (N/A, Yes, No): Training and Pre-Job Safety Briefing ·All employees onsite shall be made aware of the specific hazards of this project and review this HJA during a pre-job briefing, and their signature indicates awareness of site conditions and the plan to eliminate any hazards identified prior to and during the project. ·Crew leader (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): ·Crew member (name/title): Airborne Contaminants: ·Asbestos-containing (Transite) piping (ACP) - Do not disturb (move, drill, cut fracture, etc.) ·Asbestos-containing thermal insulation (ACI) and Asbestos-containing duct wrapping (ACW) - do not disturb, no attic or crawlspace access is allowed if work to be performed could cause exposure to personnel, client or public. ·If yes, list specific tasks and protection in place: Weather and Environment ·The site supervisor shall forecast the weather conditions at the job site, prior to crew arrival, in order to mitigate any hazards associated with inclement weather (heat, cold, wind, rain, etc.) ·The site supervisor will utilized a portable wind meter (anemometer) to verify actual onsite wind conditions, by checking at the ground and on any elevated work surface (ex, rooftop) prior to work start, at midday and prior to solar panel staging on a roof. ·Elevated work involving the moving or maneuvering of solar panels shall cease at 25mph (sustained wind) until wind subsides. ·Forecasted weather maximum temp (degrees f): Heat Related Illness Prevention ·Employees shall have access to potable drinking water that is fresh, pure, and suitably cool. The water shall be located as close as practicable to the areas where employees are working. Water shall be supplied in sufficient quantity at the beginning of the work shift to provide at least one quart per employee per hour for drinking for the entire shift. Employees may begin the shift with smaller quantities of water if they identify the location and have effective means for replenishment during the shift to allow employees to drink on quart or more per hour. The frequent drinking of water shall be encouraged. ·Shade shall be present when temperature exceeds 80 degrees Fahrenheit. When the outdoor temperature in the work exceeds 80 degrees Fahrenheit, employees shall have and maintain one or more areas with shade at all times. ·New employees must be acclimatized. New employees will be monitored by their Crew Leader (site supervisor) for the first two (2) weeks of employment or longer when necessary. ·Employees will be allowed and encouraged to implement scheduled breaks during each shift. Employees must take cool-down breaks in the shade any time they feel the need to do so to protect them from overheating. Supervisors are REQUIRED to allow employees any break period they need during high heat conditions. ·Cool Vests are encouraged for all employees at all times during periods of high heat. ·Identify the location of the closet Occupational/Industrial Clinic or Hospital in case a crew member becomes ill. What is the specific plan to provide and replenish sufficient water for all employees on site? ·If offsite replenish is necessary, where will you go to replenish water (location/address): ·Who will replenish the drinking water (name): Restroom facilities ·Employees shall have access to restroom facilities with hand-washing stations. Use of onsite restroom is at the client's discretion (location is annotated below). If client does not give permission, location of suitable restroom facilities with hand-washing stations offsite will be provided. The onsite supervisor will identify location and make arrangements to ensure all employees have access at any point. ·Restroom facilities will be (circle one): Onsite - Offsite ·If Offsite, add location name and address: Incident Reporting Procedure ·Contact your Site Supervisor Name: Phone: ·Contact your Manager Name: Phone: ·Contact your Site Supervisor Name: Phone: With: Your full name, phone number, office location, brief description of what happen and when. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE (add as many as necessary by using additional sheets) Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: PV-10 FREE D O M F O R E V E R I N D Y 8.00 TE M P L A T E CONTRACTOR LICENSE: ELECTRICAL ADMINISTRATOR ALBRIG*807C1 FREEDOM FOREVER LLC 43445 BUSINESS PARK DR #110, TEMECULA, CA 92590 Tel: (800) 385-1075 REVISED BY DATENO. SHEET: REVISIONS JOB NO: 407055 DESIGNED BY: R.P. CLIENT: WALTER SPJUT 408 MCKENZIE AVE SW, YELM, WA 98597 AHJ: CITY OF YELM UTILITY: PUGET SOUND ENERGY METER: 165250454 APN: 7530-05-01200 PHONE: (360) 960-1726 EMAIL: WALTERSPJUT@YAHOO.COM SYSTEM: SYSTEM SIZE (DC): 13 X 400 = 5.200 kW SYSTEM SIZE (AC): 3.770 kW @ 240V MODULES: 13 X FREEDOM FOREVER: FF-MP-BBB-400 MICROINVERTERS: 13 X ENPHASE IQ8PLUS-72-2-US DATE: 2/23/2024 -- -- -- - - - SAFETY PLAN GREG ALBRIGHT SCAN QR CODE TO  ACCESS REFERENCE LINK PV INSTALLATION REFERENCESFREEDOM REFERENCES BATTERY INSTALLATION REFERENCES ENPHASE SOLAREDGE TESLAINSTALL HOTLINE TESLA Storage Systems NON‐BACKUP Battery SystemsSOLAREDGE Storage SystemsEnphase Storage Systems Misc. Quick Guide FOR INSTALLATION REFERENCE ONLY V1.4 Engineering Alliance, Inc h ttps://www. eng-alliance. com 08-August-2023 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87101 Tel: 505 242 6411 Attn.: Engineering Department Subject: Engineering Certification for the Unirac NXT UMOUNT System to Support Photovoltaic Panels. The Unirac NXT UMOUNT Flush -to -Roof is an extruded aluminum rail system that is engineered to hold most framed solar modules to a roof structure and installed parallel to the roof surface. We have reviewed the NXT UMOUNT system, a proprietary mounting system for rooftop solar photovoltaic (PV) panels installation, and the U-Builder 2.0 Online tool. This U-Builder 2.0 software includes analysis for the NXT UMOUNT rail and NXT UMOUNT hardware. All information, data, and analysis are in compliance with the following codes, city ordinances, and typical specifications: Codes: 1. 2015-2018 Washington State Building Code. 2. ASCE/SEI 7-10, 7-16 Minimum Design Loads for Buildings and Other Structures. 3. International Building Code, 2015-2018 Edition w/ Provisions from SEAOC PV-2 2017. 4. International Residential Code, 2015-2018 Edition w/ Provisions from SEAOC PV-2 2017. 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 6. Aluminum Design Manual 2015 & 2020 Edition. The following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 95 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0°-45° Exposure Category = B, C & D Attachment Spacing: Per U-Builder 2.0 Engineering report. Cantilever: The maximum rail cantilever length is 1/3 of the adjacent span. Clearance: 2" to 10" clear from the top of the roof to the top of the PV panel. Tolerance(s): 1.0" tolerance for any specified dimension in this report is allowed for installation. Installation Orientation: See NXT UMOUNT Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of the roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of the roof and the PV panel is mounted on the short side. 4603 April Meadow Way, Sugar Land, TX 77479. Ph: 832 865 4757 ,a Engineering Alliance, Inc h ttps://www.eng-alliance. com Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7-10 & 7-16 Component and Cladding design. Notes: 1. U-Builder 2.0 Online tool analysis is only for Unirac NXT UMOUNT systems and do not include roof capacity check. 2. Risk Category II per ASCE 7-16. 3. Topographic factor, kzt is 1.0. 4. Array Edge Factor YE = 1.5 5. Average parapet height is 0.0 ft. 6. Wind speeds are LRFD values. 7. Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder 2.0 design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-Builder 2.0 software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U-Builder 2.0 Software is applicable to the project, and • Understand and determine the appropriate values for all input parameters of the U-Builder 2.0 software. This letter certifies that the Unirac NXT UMOUNT system, when installed according to the U-Builder 2.0 engineering report and the manufacture specifications, is in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the NXT UMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. Please feel free to call for any questions or clarifications. Prepared By Engineering Alliance, Inc Sugar Land, TX `' 08-AUG-2023 EXP.:15-DEC-2023 4603 April Meadow Way, Sugar Land, TX 77479. Ph: 832 865 4757