Loading...
Building Plans; < 5 OR MORE ; ; N 4'-4j' 6'-0' 14'-9' 3'-0' 3'-0' 6. 4/Ox4/O XO SG 6/Ox4/1 Xo R4S EGRESS ' SOAKING 6' SLUDE IN 0 I JN.I.C. 8' CLG. OPT. GLASS `Q EF I 50 CFM 40 MSTR. BATH 0 iX I 8' CLG. MASTER BEDROOM 110V L - - - _0. 4 VAULTED CLG. 50 FFMM OPT. FLAT W O/ 2X6 COFFER O O F B.P. Ln M • 7I � O i iOil! 0 Ln ;t Oin � 01 It J1 • I ME PLAYROOM 8' CLG. SHELF IOV �.D. 110V Do ® 4/0x /0 FX S.D. B.P. 4-1 O BEDROOM-4 d e 8' CLG. w A 4'-0' 6'-0' 4'-0' 5'_7' 3-_0- 14'-0' 10'-6' 5'-6' J. 30' -0' UPPER fLO® PLAN ELEVA710N IIA II I/411 I'-O" INTERIOR STAIRWAY ILLUMINATION PER SEC R3031 I INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING; WIRING:. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN I FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS PROVIDED. EXTERIOR STAIRWAY ILLUMINATION PER SEC R303.8 IRC EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. UTILITY ROOM NOTES/MAKE UP Al PER IRC G2439 1. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION AND THE EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS 35 FT., THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT OF THE EXHAUST DUCT CONNECTION PER G2439.IB. 2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED WITH MAKE UP AIR WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAYING AN AREA OF NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR MEANS PER G243c3B. < 100 SQ INCH TRANSFER GRILL 2' MI a N 14'-6' 15'40' i'-3' i'-3' 1'-31' J. J. HVAC UNIT -110 BE MODEL CARRIER HEAT FE4ANF002 I MIN. HSPF OF 9.5 HEA PUMP PUMP t0 BE MODEL CARRIER 25VNA824530 `L DINING ROOM 0X V CLG. OW (X /\ .4 o - K I TCHE j CLG. Z O9 I x SINK I 4 M OPT I W C.T. W/ MICRO ABOVE O D EP. OPT. 00 CFM DBL. VTOS OVEN O F. r I � PNTR. 2X6 WA GDcH III. x 61 8/0x /0 XOX OPT. ' BUILT-IN 8' l'-4 GREAT ROOM i 9' CLG. METAL FIREPLACE INSTALL PER MFR SPECS. PROVIDE 6' J SQ. IN. OUTSIDE AIR D.V. OPT. ' BUILT-IN -3 - - . UP -; 110V R T C I R� O° �� C/A P R 2. DEN V CLG. SD. 2 AIR C.M. TALL WALL W/ COFFERED _41 I P PE RAIL �I I PER I.R.C. TYP. II 0� xi I OPEN TO ABOVE 2X6C�EED L----------� - 3'-0' 2'-8'X. `1'ELECTRIC WATE 134' MIN. SOLID CORE °O I40 LIN HEATER WITH SELF CLOSING DOOR HWH WOOD,STEEL 4 I� INTEGRATED HE OR 20 MIN. RATED SG PUMP TIER III 7777 NEAR SPEC, 6' MODEL RHEEM PROPH50 VEHICLE IMPACT BARRIER 0 HWH NOTES - PROVIDE EXPANSION TANK IN COVERED - PROVIDE SEISMIC STRAPPING PORCH - TPRV TO TERMINATE t0 9w1GR• CONC. OUTSIDE - PILOT 4 CONTROLS TO BE IV 0 MIN. OFF FLOOR 50 F* ' - PER ASH RAE 90-A-80 e H 0 - NAT GAS WATER HTR W/ MIN. EF OF 01o2 HE t DETECTOR 2/0x4 to SH - ELECTRIC WATER HTR W/ MIN. EF INT RCONNECTED RAIN GLS. OF 0.93 (SAR &E PER 314.2.3 - - - - USE 1/2' GWB ON ALL WARM AND STRUCTURAL WALLS. (1) LAYER 5/6' TYPE 2'-3' 3'-3' 'X' ON CEILINGS. WRAP ALL EXPOSEp POSTS AND BEAMS IN 1/2' GWB N4 NO DUCT OPENINGS of IN GARAGE. DUCTS THROUGH CLG OR WALL COMMON TO HOUSE, MIN. 26 GAGE STEEL. Ic,ia� Y A/oj nu nnna IG_Aan BLUE 18 AWG TRACER g_6. WIRE REQUIRED AT NONJ. - METAL WATER SERVICE PIPING PER UPC 604.9 J. LANDING AT 'EXIT' DOOR NOT TO BE LOWER THAN 1.5 INCHES FROM TOP OF THRESHOLD. 0 113.1) 2X STUD WALL / CONC WALL 2-1/4' 0 X 5' LAG SCREWS • STUD WALL 2-3/8' 0 X 5' BOLTS W/ SIMPSON VCsC ADHESIVE * CONC WALL 16 GA STEEL STRAPPING AROUND WATER HEATER WITHIN THE UPPER 4 LOWER ONE-THIRD OF THE APPL. 4 A MIN. OF 4' FROM CONTROLS HOLD WATER HEATER TIGHT TO GWB • BACK FLEXIBLE WATER CONNECTIONS 2X4 LEDGER PRESSURE TREATED ® CONC WALL 16 GA STEEL STRAPPING AROUND WATER HEATER WITHIN THE UPPER 4 LOWER ONE-THIRD OF THE APPL. 4 A MIN. OF 4' FROM CONTROLS ANCHOR WH TO BASE - BASE TO FLOOR NO SCALE WATER HEATER SUPPORT 9' -6' 5'-6' 5'-6' 30'-0' MAIN r-LOOR FLAN MAIN r-LOOR: 1065 50. f227. UFPrER FLOOR: 1522 50. IT. TOTAL: 2385 50. f22T. GARAGE: 5411 50. r-T. FRONT PORCH: rtrt 50. F0'4T. REAR PORCH: I OCI 50. f=T I. COPYRIGHT 2010 Landmark Design Inc. ALL RIGHTS DESERVED 9 m aD � N M w 1O I_ ;5 Ocn Q N cn m m 1V GENERAL NOTES: 1. ALL WORK TO BE IN CONFORMANCE WITH 2O18 IRC. 2. VENT ALL EXHAUST FANS, DRYER VENTS AND RANGES TO OUTSIDES. 3. VENT WATER HEATER PRESSURE RELIEF VALVES TO OUTSIDE. 4. PROVIDE FIRE BLOCKING AT ALL PLUMBING AND MECHANICAL PENETRATIONS. 5. ALL SHOWER WALLS TO BE WATERPROOF TO MINIMUM 12' ABOVE DRAIN. 6. SHOWERHEADS 4 KITCHEN FAUCET TO BE LIMITED TO MAXIMUM 1.15 G.P.M. FLOW. ALL OTHER LAVATORY FAUCETS TO BE LIMITED TO MAXIMUM 1.0 G.PT I FLOW. 1. ALL GLAZING WITHIN II ABOVE DRAIN INLET TO BE SAFETY GLASS. 8. ALL GLAZING WITHIN 24' OF DOOR OR WITHIN 18' OF FLOOR TO BE SAFETY GLASS S. SMOKE ALARMS - TO BE INSTALLED PER SEC R3143 IN THE FOLLOWING LOCATIONS: IN EACH SLEEPING ROOMS, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY Or - THE BEDROOMS. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS, AND ALARMS TO BE INSTALLED NOT LESS THAN 3 FT. HORIZONTALLY FROM A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER ALARMS TO BE INTERCONNECTED IN SUCH A MANNER THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. =SMOKE ALARM -CARBON MONOXIDE COMBO. C 10. PROVIDE CARBON MONOXIDE ALARMS PER SEC. R315 AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED ON EACH FLOOR 4 OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. PER 2018 IRC 4 WA. STATE AMENDMENTS SEC R315. 11. INSULATE ALL WATER PIPES TO MINIMUM R-3 PER 0 WSEC R403B3. 12. ALL DUCTS 4 EXHAUST DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-8 PER WSEC R4033.1. DUCTS WITHIN A CONCRETE SLAB OR IN THE GROUND SHALL BE INSULATED TO R-10 WITH INSULATION DESIGNED TO BE USED BELOW GRADE. 13. EXHAUST AIR SHALL NOT BE DIRECTED ONTO WALKWAYS. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. PER R303B2. 14. GAS PIPING IS TO BE PROTECTED PER G2415.1. WHERE PIPING IS INSTALLED THROUGH HOLES OR NOTCHES IN FRAMING MEMBERS AND THE PIPING IS LOCATED LESS THAN 1-1/2 INCHES FROM THE FRAMING MEMBER FACE TO WHICH WALL, CEILING OR FLOOR MEMBRANES WILL BE ATTACHED, THE PIPE SHALL BE PROTECTED BY SHIELD PLATES THAT COVER THE WIDTH OF THE PIPE AND THE FRAMING MEMBER AND THAT EXTEND NOT LESS THAN 4 INCHES TO EACH SIDE OF THE FRAMING MEMBER WHERE THE FRAMING MEMBER THAT THE PIPING PASSES THROUGH IS A BOTTOM PLATE, BOTTOM TRACK, TOP PLATE OR TOP TRACK, THE SHIELD PLATES SHALL COVER THE FRAMING MEMBER AND EXTEND NOT LESS THAN 4 INCHES ABOVE THE BOTTOM FRAMING MEMBER AND NOT LESS THAN 4 INCHES BELOW THE TOP FRAMING MEMBER 15. ATTIC 4 CRAWL ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES 16. WHOLE HOUSE VENTILATION 24 HR TIMER, READILY ACCESSIBLE 4 WITH LABEL AFFIXED TO CONTROL THAT READS 'WHOLE HOUSE VENTILATION' (SEE OPERATING INSTRUCTIONS) 11. DRYER DUCT SPECIFIED LENGTH PER SEC 1" 11502.4B.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET00.668mm) FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH THE TABLE M1502.4B.1. THE MAXIMUM LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. 18. CAVITIES WITHIN CORNERS AND HEADERS Or - FRAME WALLS SHALL BE INSULATED BY COMPLETELY FILLING THE CAVITY WITH A MATERIAL HAVING A THERMAL RESISTANCE OF R-3 PER INCH MINIMUM PER 2018 WSEC TABLE R402A.1.1. WHOLE HOUSE VENTILATION: REFER TO SHEET N-2 TABLE 1505A30) 4 1505A3(2) FOR FAN SIZING AND RUN TIMES FURNACE t0 HAVE A DUCT FOR OUTSIDE AIR, MOTORIZED DAMPER WITH TIMER AND CONTROLS ARE TO BE ADDED FOR THE REQUIRED FRESH AIR EXCHANGE. Z V1 00 as 0 W E Go 22 N •a• F A gym z o A M h N� 0 �a 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans should not be altered by other than a qualified designer, archi- tect, or structural engineer. 1 Plan No: 1 L2-2385-2L Date: 12-15-21 J /// i " � O X � ' N 0 � 0 N � x _ N M � � 0 C4 UTILITY ROOM NOTES/MAKE UP Al PER IRC G2439 1. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE BUILDING CONSTRUCTION AND THE EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS 35 FT., THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6 FT OF THE EXHAUST DUCT CONNECTION PER G243S.IB. 2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED WITH MAKE UP AIR WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ. INCHES FOR MAKE UP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY OTHER APPR MEANS PER G243c3B. L _j = 100 SQ INCH TRANSFER GRILL B.P. BEDROOM-2 8' cLG. lIOV e s.D. 41_9N 6 2X6 WALL s .,. OW, 7/ FLT. CLG. LINE \ 0 S.D. 4'_i• I PLAY OOM VAULTED CLG. I I I I I I xox I I I 21 4j' r: 110V 4M ,n ii�!-��f%f7�11■fc�l�c �1 X e N x 0 OPEN TO BELOW 10 r® S.D. B.P. BEDROOM-4 8' CLG. EGRESS Ox4/0 XO SHELF Fx 01 14'-0' 10'-6' S'-6' _ UPPER i #LCC FLAN L X A7I ON II� II 1/4"=1'—O" WHOLE HOUSE VENTILATION: *REFER TO SHEET N-2 TABLE 1505.4.30) 4 1505A 3(2) FOR FAN SIZING AND RUN TIMES FURNACE TO HAVE A DUCT FOR OUTSIDE AIR, MOTORIZED DAMPER WITH TIMER AND CONTROLS ARE TO BE ADDED FOR THE REQUIRED FRESH AIR EXCHANGE. -ytv fn rom to t C4 0 N an FOUNDATION NOTES: 1. ALL FOOTINGS TO BEAR ON FIRM UNDISTURBED SOIL. 2. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED. 3. ALL BEAMS TO BE 4x10 DFL *2 ON 4x4 POSTS (4x6 AT SPLICES) ON 24' D IA. x 8' CONC. PADS UNLESS NOTED OTHERWISE. 4. ALL POSTS TO BE ANCHORED AGAINST LATERAL MOVEMENT. 5. SOLID BLOCK AT ALL POINT LOADS FROM ABOVE. 6. FLOOR JOISTS SHOULD BE SUPPORTED LATERALLY AT EACH END AND AT EACH SUPPORT, BY SOLID BLOCKING OR BY ANOTHER APPROVED METHOD. -1. PROVIDE MINIMUM 18'-24' CRAWL ACCESS. •CRAWL ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. 8. PROVIDE CRAWL SPACE VENTILATION PER IRC SECTION R408. *FOUNDATION VENTS SHALL BE PLACED SO THAT THE TOP OF THE VENT IS BELOW THE LOWER SURFACE OF THE FLOOR INSULATION. S. INTERIOR GRADE OF CRAWL SPACE SHALL BE SLOPED TO DRAIN AND INSURE THE REMOVAL OF WATER 10.PREVENT WOOD TO GONG. CONTACT W/CONT. FLASHING OR APPROVE MEMBRANE. 11. / INDICATES 'SIMPSON' HOLDDOWN. 12. aSEE SWEARWALL SCHEDULE FOR ANCHOR BOLT SIZE d SPACING (SHT 51.0). r r—O UN A 7 I O NFLAN L X A 7 1 O N ''All IAII 4 II II I/4"=1'—O" STWD EDGE DISTANCE 1-1/2' MIN BUILDER TO DETERMINE IF STHD OR STHD/RJ IS APPROPRIATE. 12' MINIMUM AWAY FROM HOLDOWNS COPYRIGHT 2010 Landmark Design Inc. ALL RIGHTS RESERVED VENTILATION CRAWL SPACE VENTILATION TOTAL NET FREE AREA USE 3' x 3' x 1/4' REQ,D 1063/150 = 1.08 SQ. FT. GALVANIZED STEEL PROVIDE SCREENED VENTS SQUARE PLATE FOR VENTILATION WASHERS FOR ALL 1 � ���TJ �� Q � ANCHOR BOLTS z V z a ♦♦♦ E yN O � SON A gym oo yn ton N� O �a 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. Plan No: L2M-2385-2L Date: 12-15-21 �I v ROOF VENTILATION CALCULATIONS 4 fiRE aU 1 fiREMENTS AT LEAST 40%4 NOT MORE THAN 509. OF REQUIRED VENTS SHALL BE IN UPPER PORTION OF VENTILATED ROOF SPACE (NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT) WITH THE BALANCE OF REQUIRED VENTILATION PROVIDED BY EAVE VENTING. VENTILATION REQUIRED PER SEC. R806.1 - ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSIONS OF 1/16' INCH MINIMUM AND 1/4' INCH MAXIMUM. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4' SHALL BE PROVIDED WITH CORROSION -RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF 1/16' MINIMUM AND 1/4' MAXIMUM. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQUIREMENTS OF SECTION R8021. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR MINIMUM VENT AREA PER SEC. R8062 - THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE. VENT AND INSULATION CLEARANCE PER SEC. R8063 - WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR NOT LESS THAN A 1-INCH SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AND AT THE LOCATION OF THE VENT. SEE SHEET N2 FOR ROOF VENTILATION CALCULA' ROOF OVERFRAME NOTES: IRC SEC R5023 I. RAFTERS SHALL BE FRAMED TO 2x RIDGE BOARD PER PLAN. RIDGE BOARD SHALL NOT BE LESS IN DEPTH THAN THE CUT END OF THE RAFTER AT ALL VALLEYS AND HIPS THERE SHALL BE A 2x VALLEY OR HIP RAFTER AND NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER (FULL COVERAGE AT RIDGE, HIPS AND VALLEYS). ROOF FRAMING NOTES: 1. ALL HEADERS TO BE 4x8 OF 02, UNLESS NOTED OTHERWISE. HEADERS AT EXTERIOR WALLS E WARM WALLS TO BE INSULATED W/R-10 RIGID INSULATION. 2. ALL OTHER TRUSSES: • SHALL CARRY MANUFACTURERS STAMP. • SHALL HAVE DESIGN DETAILS AND SPECIFICATIONS ON SITE FOR FRAME INSPECTION. = SHALL BE INSTALLED AND BRACED PER MANUFACTURERS SPECIFICATIONS PER IRC SEC. 502.112 AND 802.103 AS WELL AS THE TRUSS INSTITUTE'S BUILDING COMPONENT SAFETY INFORMATION. 3. NO TRUSS SHALL BE FIELD -MODIFIED WITHOUT PRIOR CONSENT OF THE TRUSS ENGINEER AND THE BUILDING DEPARTMENT. 4. PROVIDE ATTIC ACCESS AT A MINIMUM OF 22'x3O' PER IRC SEC. R801.1. *ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. 5. PROVIDE ATTIC VENTILATION PER IRC SEC. R806. ALL FRAMING TO COMPLY WITH IRC SEC R802. 6. aA REFER TO SHEAR WALL SCHEDULE. MANUFACTURED TRUSSES MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE ON SITE AT TIME OF INSPECTION, FOR THE INSPECTORS USE AND REFERENCE (3) LSTA16 - TO TOP (EACH (TYP OF 2) /� 001 r—RA'�-III 6 LAN I/4"=1'-O" R302.12.1 MATERIALS. DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN 1/2' GYPSUM BOARD, 3/6' WOOD STRUCTURAL PANELS OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. DRAFTSTOPPING SHALL BE INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBER UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL. THE INTEGRITY OF THE DRAFTSTOPS SHALL BE MAINTAINED. DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SF. SUB -FLOOR PER PLAN FLOOR TRUSS PER PLAN GWB is CEILING TRUSS EDGE VIEW TRUSS LENGTH VIEW TRUSS EDGE VIEW 0 GARAGE WALL TRUSS TOP VIEW is GARAGE WALL SUB -FLOOR PER PLAN FLOOR TRUSS PER PLAN GWB ,@ CEILING SUB -FLOOR PER PLAN FLOOR TRUSS PER PLAN LATERAL BLOCKING PANELS w/ DRAFTSTOPPING GWB 9 CEILING FLOOR TRUSS PER PLAN GARAGE WALL BELOW LATERAL BLOCKING PANELS w/ DRAFTSTOPPING ;-GALE: 1/2' - I'-V' DRAFTSTOPPING DETAIL PT POST W/ CAP :OF 2) FRAMING NOTES: 1. ALL MULTIPLE JOISTS OR BEAMS MUST BE BOTH GLUED AND NAILED W/8d NAILS m 24' O.G. NAILED TOP E BOTTOM STAGGERED EACH SIDE. 2. ALL HEADERS TO BE 4x8 OF 02, UNLESS NOTED OTHERWISE. HEADERS AT EXTERIOR WALLS d WARM WALLS TO BE INSULATED W/R-10 RIGID INSULATION. 3. SOLID BLOCK BENEATH ALL POINT LOADS FROM ABOVE. 4. FLOOR JOISTS SHOULD BE SUPPORTED LATERALLY AND SUPPORTED BY SOLID BLOCKING OR BY ANOTHER APPROVED METHOD. 5. MSTC 40 STRAPS PER STRUCTURAL, UNLESS NOTED OTHERWISE 6. a REFER TO SHEAR WALL SCHEDULE. (4) :ONT. DBL. TOP PLATE it-10 R1610 INSULATION SHADED AREA) 4X HEADER EXTERIOR PLYWOOD TRIMMER HEAnER/INSULATION nE7A1L xrs LSTA36 - HDR E SILL TO 3x BLOCKING. CTYP. 2 PLACES) LSTA24 - BEAM 8 FTO TOP PLATE 52.0 (TYP OF 2) �t�Q I �L; f i�QQ I' I I I �� I 1/4" = I'-O" NOTE - FASTENERS FOR TREATED WOOD TO BE HOT -DIPPED GALVANIZED, STAINLESS STEEL, SILICONE, BRONZE OR COPPER STUD NOTCHING AND BORING - BEARING OR EXTERIOR WALL NOTCH 25%, BORING 4056. - 6096 BORING IF DOUBLED d LESS OR EQUAL SUCCESSIVE STUDS. - NON -BEARING MAXIMUM NOTCH 4090, BORING 6090. - HOLES NO CLOSER THAN 5/8 INCH TO FACE OF STUD. z 06 r--� ir M W 00 as W .:. a z a ♦♦♦ E yN E Go U OWN A gym M h N� 0 �a z 0 w a w 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. Plan No: L2M-2385-2L Date: 12-15-21 i] IRCOF VENTILATION CALCULATION& 4 REQUIREMENTS AT LEAST 409164 NOT MORE THAN 5096 OF REQUIRED VENTS SHALL BE IN UPPER PORTION OF VENTILATED ROOF SPACE (NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT) WITH THE BALANCE OF REQUIRED VENTILATION PROVIDED BY SAVE VENTING. VENTILATION REQUIRED PER SEC. R806.1 - ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSIONS OF 1/16' INCH MINIMUM AND 1/4' INCH MAXIMUM. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4' SHALL BE PROVIDED WITH CORROSION -RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF 1/16' MINIMUM AND 1/4' MAXIMUM. OPENINGS IN ROOF FRAMING MEMBERS SHALL CONFORM TO THE REQUIREMENTS OF SECTION R8021. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR MINIMUM VENT AREA PER SEC. R8062 - THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE. VENT AND INSULATION CLEARANCE PER SEC. R8063 - WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR NOT LESS THAN A 1-INCH SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AND AT THE LOCATION OF THE VENT. SEE SHEET N2 FOR ROC (3) (TYP OF 2) ROOF OVERFRAM E NOTES: IRC SEC R8023 1. RAFTERS SHALL BE FRAMED TO 2x RIDGE BOARD PER PLAN. RIDGE BOARD SHALL NOT BE LESS IN DEPTH THAN THE CUT END OF THE RAFTER AT ALL VALLEYS AND HIPS THERE SHALL BE A 2x VALLEY OR HIP RAFTER AND NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER (FULL COVERAGE AT RIDGE, HIPS AND VALLEYS). ROOF FRAMING PLAN 1/4"=1 I -oil R302.12.1 MATERIALS. DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN 1/2' GYPSUM BOARD, 3/6' WOOD STRUCTURAL PANELS OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. DRAFTSTOPPING SHALL BE INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBER UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL. THE INTEGRITY OF THE DRAFTSTOPS SHALL BE MAINTAINED. DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SF. SUB -FLOOR PER PLAN FLOOR TRUSS PER PLAN GWB 161 CEILING TRUSS EDGE VIEW TRUSS LENGTH VIEW TRUSS EDGE VIEW 6 GARAGE WALL TRUSS TOP VIEW 0 GARAGE WALL SUB -FLOOR PER PLAN FLOOR TRUSS PER PLAN GWB 9 CEILING SUB -FLOOR PER PLAN FLOOR TRUSS PER PLAN LATERAL BLOCKING PANELS w/ DRAFTSTOPPING GWB 9 CEILING FLOOR TRUSS PER PLAN GARAGE WALL BELOW LATERAL BLOCKING PANELS w/ DRAFTSTOPPING SCALE: 1/2' - 1'-0' 1;)RAFT5T0PPIN6 DETAIL ROOF FRAMING NOTES: 1. ALL HEADERS TO BE 4x8 OF 02, UNLESS NOTED OTHERWISE. HEADERS AT EXTERIOR WALLS t WARM WALLS TO BE INSULATED W/R-10 RIGID INSULATION. 2. ALL OTHER TRUSSES: = SHALL CARRY MANUFACTURERS STAMP. SHALL HAVE DESIGN DETAILS AND SPECIFICATIONS ON SITE FOR FRAME INSPECTION. • SHALL BE INSTALLED AND BRACED PER MANUFACTURERS SPECIFICATIONS PER IRC SEC. 502.112 AND 802.103 AS WELL AS THE TRUSS INSTITUTE'S BUILDING COMPONENT SAFETY INFORMATION. 3. NO TRUSS SHALL BE FIELD -MODIFIED WITHOUT PRIOR CONSENT OF THE TRUSS ENGINEER AND THE BUILDING DEPARTMENT. 4. PROVIDE ATTIC ACCESS AT A MINIMUM OF 22'x3O' PER IRC SEC. R801.1. *ACCESS HATCHES OR DOORS SHALL BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. 5. PROVIDE ATTIC VENTILATION PER IRC SEC. R606. ALL FRAMING TO COMPLY WITH IRC SEC R802. 6, aA REFER TO SHEAR WALL SCHEDULE. MANUFACTURED TRUSSES MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE ON SITE AT TIME OF PT POST W/ INSPECTION, FOR THE INSPECTORS USE AND CAP REFERENCE 'OF2) FRAMING NOTES: 1. ALL MULTIPLE JOISTS OR BEAMS MUST BE BOTH GLUED AND NAILED W/8d NAILS m 24' O.G. NAILED TOP 4 BOTTOM STAGGERED EACH SIDE. 2. ALL HEADERS TO BE 4x8 OF 02, UNLESS NOTED OTHERWISE. HEADERS AT EXTERIOR WALLS # WARM WALLS TO BE INSULATED W/R-10 RIGID INSULATION. 3. SOLID BLOCK BENEATH ALL POINT LOADS FROM ABOVE. 4. FLOOR JOISTS SHOULD BE SUPPORTED LATERALLY AND SUPPORTED BY SOLID BLOCKING OR BY ANOTHER APPROVED METHOD. 5. is MSTC 40 STRAPS PER STRUCTURAL, UNLESS NOTED OTHERWISE 6. a REFER TO SHEAR WALL SCHEDULE. (4) LSTA36 - HDR E SILL TO 3x BLOCKING. PLACES) 8 52.0 1/41I= 1'-OII :ONT. DBL. TOP PLATE ?-10 RI(S1D INSULATION SHADED AREA) 4X HEADER EXTERIOR PLYWOOD TRIMMER HEAnER/I NSULAT I ON flETA I L NTS LSTA24 - BEAM 'TO TOP PLATE NOTE - FASTENERS FOR TREATED WOOD TO BE HOT -DIPPED GALVANIZED, STAINLESS STEEL, SILICONE, BRONZE OR COPPER RIGHT 2010 k Design Inc. 4TS IMSERVED STUD NOTCHING AND BORING - BEARING OR EXTERIOR WALL NOTCH 25%, BORING 409a. - 6096 BORING IF DOUBLED 4 LESS OR EQUAL SUCCESSIVE STUDS. - NON -BEARING MAXIMUM NOTCH 4090, BORING 6090. - HOLES NO CLOSER THAN 5/8 INCH TO FACE OF STUD. z 0 .� I --I Con�a " M W APQ z a ♦♦♦ E yN E Go � OWN A gym z o M h N� 0 �a z 0 w a w 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. Plan No: L2M-2385-2L Date: 12-15-21 I� L'J 12 s I I I MIN N I I 1i MIN N in N OR 01 HT820 BM - TOP PLATE M 0 FRONT EL.E\lATION P M 8/01 x 8/0 O.H. DOOR 8'-3' 12 8 I GARAGE USE 1/2' G B ON ALL WARM AND STRUCTURAL WALLS. (1) LAYER 5/8' TYPE 'X' ON CEILINGS. WRAP ALL EXPOSED POSTS AND BEAMS IN 1/2' GWB 3 NO DUCT OPENINGS YVflR. �S�G�� 52.0 IN GARAGE. DUCTS THROUGH CLG OR P, WALL COMMON TO HOUSE, 6 l ) 2 MIN. 26 GAGE STEEL. 82 0 Z 51/2 x 13B U 6X6 PT POST W/ 72/0>5/0 SH CCQ CAP RAIN GLS. 8Q3 P/4XI8 LVL El �5 FLOOR GIRDER 9 2.0 LLL U_ 7C 8'-0' 16/0 x 6/0 O.H. DOOR 16'-3' RO. CHAMPF R TOP 10'-0' 19'-0' TO MATCHTHING MAIN FLOOR PLAN/FRAMING 5cl1 50. r-T. E 1, R00i I A1v1`INC7 PLAN 1/4"=1'-0" J=CUNZ�A71 ON FLAN 1/4"=1'-0" STWD EDGE DISTANCE 1-1/2' MIN BUILDER TO DETERMINE IF STHD OR STHD/RJ IS APPROPRIATE. 12' MINIMUM AWAY FROM HOLDOWNS ADJUST CRAWL SPACE VENTS TO BE ZCh T� ®. °` V 39; COO.) x� w w� A .;. z M 0 V] N a000 A �j z gyN za ton N 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. I Plan No: I L2M-2385-2L Date: 12-15-21 11 12 8 i GABLE OPTION r- — — — — — — — — — — OMNI I MIN ME I oil MIER 1111 IMMERSION# WT520 BM - TOP PLATE m 0 FRONT ELEVATION /4"=1'-0" 3 S2 0 6AR 6r= USE 1/2' GWB ON ALL WARM AND STRUCTURAL WALLS. (1) LAYER 5/6' TYPE 'X' ON CEILINGS. WRAP ALL EXPOSED POSTS AND BEAMS IN 1/2' GWB NO DUCT OPENINGS IN GARAGE. DUCTS THROUGH CLG OR WALL COMMON TO HOUSE, 6 `a I MIN. 26 GAGE STEEL. 2a ZOO 51/2 x 13B VAX 6X6 PT POST W/ \� CCQ CAP 8/01 x 8/0 O.H. DOOR i 16/0 x 8/0 O.H. DOOR 16'-3' RO. S 2/0xd5/0 SH RAIN GLS. TOP 1'-6' 8'-0'EllPTO MATG 10'-0' 15'-0' ROOF SHEATHING 40'-0' MAIN FLOOR PLAN/FRAMING 5411 50. FT. COPYRIGHT 2010 Landmark Design Inc. ALL RIGHTS RESERVED 10 (TYP OF 2) 00i I A1vIINC7 PLAN 1/4"=1'-0" T=CUNDA71 ON PLAN STHD EDGE DISTANCE 1-1/2' MIN BUILDER TO DETERMINE IF STHD OR STHD/RJ IS APPROPRIATE. 12' MINIMUM AWAY FROM HOLDOUINS ADJUST CRAWL SPACE VENTS TO BE PT POST W/ GAP 'OF2) Z T� ® V 3 w A .;. z M 0 V] N 00 a0 A gyN z ton N 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. I Plan No: I L2M-2385-2R Date: 12-15-21 2X6 MIN. 6x6 PT POST BARGE BOARD STAIR NOTES: HANDRAIL TO BE PRESENT ON SOLID TIGHT FITTING: TRUSS BLOCKING END TRU55 PER IRC R311.7 4' SPHERE SHALL ON At LEAST ONE SIDE OF STAIR (SEE DETAIL THIS SHEET FOR SAVE (HOLD OW TRUS5 IN PROM PACE OF WALL) • STRINGERS TO BE FIRE BLOCKED AT BOTH TOP AND HANDGRIP PORTION OF HANDRAILS NOT PASS THROUGH HAVE IRULLAR CROSSSECTIONHAVE VENTING) BOTTOM. SHALL 2 2x8 FASCIA BOARD 5/611 TYPE X SWB • ALL USABLE SPACE UNDER STAIRS TO BE I HOUR A MIN. RADIUS OF t1s'. 4 C. ALL REQUIRED GUARDRAILS TO BE 36' X 6N6 CONSTRUCTION MIN. IN HEIGHT. • MAXIMUM RISE t0 BE 7-3/4'. OPENINGS FOR REQUIMD GUARDS ON NAILER No' TYPE 'X' GWB • MINIMUM RUN TO BE 10'. THE SIDES OF STAIR TREADS SHALL NOT MINIMUM HEAD HEIGHT TO BE V-8'. ALLOW A SPHERE 4 INCHES (102mm) TO PASS TWRDUGH. 2x6 "2 OF STUDS �► 16' O.C. n6 L"FLAMEBLOCK FIRE -RATED 'i/Ib" LP PLAMEBLOGK • MINIMUM STAIR WIDTH t0 BE 36'. • PROVIDE CONTINUOUS HAND RAIL 34' t0 38' OFF 34' MN-I1is' MAX ATTACH STUDS TO TOP 4 BOTTOM PLATE WITH OSB SHEATHING W/IBmm PYROTITE TREAD NOSING AND Must EXTEND BEYOND BOTTOM NOSING (3) 16d FRAMING NAILS. LAMINATE APPLIED TO ONLY ONE FACE �,qD. 1: JST. PER PLAN CONSTRUCT TOP PLATE OF (2) STUDS OF WOOD PANEL. SHEATHING MUST BE 5/b" rnE x bra SIDING OR TRIM PER PLAN PROVIDE GUARD RAILS AT LANDINGS MINIMUM 36' p m INSTALLED HORIZ. AT THE TOP OF THE GYPSUM INSTALLED VERTICALLY W/HORIZONTAL P-MERIOR WALL CoveRINS: NIGH W/ CLEAR SPACE a WALL ASSEMBLY AND THE BOTTOM PLATE OF JOINTS BLOCKED 4 W/PYROTITE I. PIBER CEMENT BOARD 2. TI-11 SIVIN5 No SCALE HANDGRIP PORTION OF HANDRAIL SHALL BE A SINGLE STUD. INSTALL 2x6 WOOD STUDS LAMINATE FACING THE OUTSIDE 4 MUST S. WOOD PIBER PANEL NOT LESS 11/4' NOR MORE THAN 2' IN F - VIp pBL. JST O BEAM FULE COVERAGE A COW HORIZ. AS CROSS -BRACING POSITIONED AT " BE ATTACHED TO THE STUDS W/11�8 6d 4. CEMENT PLASTER (STUCCO) POST DETAIL FOR STRUCTURES CROSS SECTIONAL DIM. to 10' MIN 10 TIE AT EA STRINGER MID -HEIGHT OF THE WALL. COMMON NAILS SPACED 6 O.G. AROUN s. STML SIVINS A4�FROM LESS THAN 5' •WINDING TREADS PERIMETER 12' O.0 IN THE FIELD. PROPERTY LINE PER IRC R3n.i52.t� TO PASS THROUGH OPENING • SPIRAL STAIRS aBELOW a STAIR SAND 2X6 WALL STUD a l�/ IN 3� PROVIDE MIN 1 1/2' RUN ® A POINT 12' A GWB •CEILING WALLS 5112' THICK NOMINAL 3 PCF DENSITY FROM WHEN TREAD 15 NARROWEST (3) 2X12 STRINGERS UNFACED MINERAL FIBER BATT AF50 ROOF VENTS PER IRC R3u.7.10a / 5, : a TYPE X: GWB APPLIED VERTICALLY INSULATION FRICTION FIT BETWEEN THE THICKNESS:=-'I/S" (PIRE) 'I (50 50. IN. NET FREE AREA) FIRE BLOCKING • MID -SPAN AND W/ HORIZONTAL JOINTS BLOCKED AND WOOD STUDS, CROSS -BRACING 4 APPROX. YCISHT: PSP (PIRE) FIRM TEST: UL RI319, 9-12-�16 CONY. HANDRAIL 34'-38' / r N STUD WALLS ALONG AND N LIFE WITH STRINGERS IF AREA UNDER FASTENED W/6d CEMENT COATED 11�g' FASTEN COATED I' TOPA50TTOM PLATES. UL 17ESISN U3B8 ABOVE TREAD NOSING. / NOTCH STRINGERS FOR CONT. 2X4 THRUST BLOCK STAIRS IS UNFINISFED CUP-H4 AD DRYWALL NAILS PICKETS PER IRC 2X4 THRUST BLOCK SHANK DIA. 4 1/ ' HEAD DIA. SPACED 8' I �7 S�E � P I RE�i �� META I L SOLID TIGHT FITTING TRUSS BLOCKING ON OPEN SIDE / JST- cl AILS BELOW W/ Ibd NAILS • 12' Oc. O.C. ALONG STUDS 4 PLATES. EXPOSED WEATHER BARRIER FASTENED OVER TH / TO THRUST BLOCK INTERIOR FASTENER HEADS AND WALLBOARD SHEATHING USING SUFFICIENT FASTENERS LESS THAN V TO THE PROPERTY LINE I, PT RISERS JOINTS MUST BE TREATED W/(2) GOATS TO PREVENT AIR POCKETS IN THE WRAP 2x8 FASCIA BOARD i / JOISTS PER PLAN OF GYPSUM COMPOUND. A MIN. 2' PAPER, GA FILE NO. AP 5640 (GENERIC I HOUR) DBL JST PLASTIC OR FIBERGLASS TAPE MUST BE ONE LAYER s, ' TYPE X GWB APPLIED a 2x STUDS PER PLAN P.T. 2XI2 EMBEDDED IN FIRST LAYER OF EXTERIOR WALL COVERING: PARALLEL OR AT RIGHT ANGLES TO TREADS HU212 COMMPOUND OVER WALLBOARD JOINTS. 1. FIBER CEMENT BOARD EACH SIDE OF MIN 2X3 STUDS, TURNED 7%' SHEATHING TO SYRINGE MTL. HANGERS 2. TI-11 SIDING 24 O.C. WITH rod AT EA. STRINGERFLATWISE, 3. WOOD FIBER PANEL 4. CEMENT PLASTER (STUCCO) CEMENT -COATED NAILS, 1-1i8' LONG, EXTERIOR WALL COVERING 3-2X12 P.T. STRINGERS 5. STEEL SIDING 0.0915 SHANK, 1/4' HEADS, -' O.C. PER PLAN 3LAND�ING HORIZONTAL JOINTS STAGGERED NOT EXTERIOR DESIGN: NCC-ES REPORT - ESR-1365) WALL TYPE 43.4 - 1 HR EXTERIOR WALL ASSEMBLY LESS THAN 12' ON OPPOSITE SIDED. coNc PAD NO SCALE NO SCALE HL 35 ANGLE SUPPORT EAVES 4 WALL WITHIN 5'-0' OF PROPERTY LINE EAVES WITHIN 5'-0' OF PROPERTY LINE PER IRC 302 E TABLE R302.1 PER IRC 302 4 TABLE R302.1 NO SCALE H I HOUR �1RE-RE515TIVE r;)ETAIL5 J TYPICAL STAIR DETAIL AND NOTES FIRE BLOCKING AND DRAFTSTOPPING: PER SECTION R302.11 • R302.12 1. IN CONGEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: A. VERTICALLY AT THE CEILING 4 FLOOR LEVELS B. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10'-0' 2. AT ALL INTERCONNCECTIONS BETWEEN CONGEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. 3. IN CONCEALED SPACES AT STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SEC. R302.1. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION. IU O al X tL J �Q0 �lu T_ :3 _ C dJ (P _I ATTIC VENTILATION AT LEAST 40% 4 NOT MORE THAN 50% OF REQUIRED VENTS SHALL BE IN UPPER PORTION OF VENTILATED ROOF SPACE (NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT) WITH THE BALANCE OF REQUIRED VENTILATION PROVIDED BY EAVE VENTING. 5EMROOM 4 FLOOR CONSTRUCTION: 3/4' T4G PLYWOOD SUB-FLR GLUED 4 NAILED TO (SEE FRAMING PLAN FOR SIZE AND SPACING) --\ &ARAGE 12 6� ATTIC SPACE ZMANUF TRUSSES 24'O.C. SEE ROOF FRAMING PLAN R-461 INSULATION BATH � IUT LIT' MEN (2)-2x4 TOP M 1/2' GWB 2x4 STUD G 16' O.G. 2x4 BOT. fE COMPOSITION ROOF W/ 300 INTERWOVEN FELT ON 1/2' 24/0 PLYWOOD SHEATHING I2 ALL ROOF FLASHING TO BE MIN. 26 GA GALV. STEEL. 6 ROOF DRIP EDGES PER SEC. R9052.8.5 \ PROVIDE DRIP EDGE AT EAVES 4 GABLES W/ A MIN. 2' OVERLAP. KITCHEN MASTER SA<Ti 4 FLOOR CONSTRUCTION: 3/4' T4G PLYWOOD SUB-FLR GLUED 4 NAILED TO (SEE FRAMING PLAN FOR SIZE AND SPACING) ---\ MINING ROOM R-36 HIGH DENSITY INSULATION a FLOOf GRADE JAI6 MIL VISQUEEN VAPOR �• BARRIER THROUGHOUT GRWLSP�rGE CRAWLSPACE. • LL- p LAP SPLICES 12' MIN. 1 TIGHTL INE FOUNDATION DRAIN: 4' DIA. PERF. PIPE PEA GRAVEL FILL WRAP W/ FILTER FABRIC SU I Ln I NG sEeT I ON 5/5"= I'—O" COPYRIGHT 2010 Landmark Design Inc. ALL RIGHTS RESERVED 2x SCREENED EAVE VENT BLOCKS WK3) 1112' HOLES EACH - PROVIDE APPROVED INSULATION BAFFLE TO ENSURE 1' MIN. AIR SPACE. TYPICAL EXTERIOR WALL: (2)2x6 TOP PLATES 2x6 STUDS a 16' O.G. 2x6 BOTTOM PLATE 1/2' SHT'G (APA RATED 24/0) AIR BARRIER EXTERIOR SIDING PER ELEV. R-21 INSULATION W/ CONT. VAPOR BARRIER (WARM SIDE) 1/2' GYP. BD STUD NOTCHING AND BORING - BEARING OR EXTERIOR WALL NOTCH 25%, BORING 40%. - 60% BORING IF DOUBLED 4 LESS OR EQUAL SUCCESSIVE STUDS. - NON -BEARING MAXIMUM NOTCH 40%, BORING 60%. - HOLES NO CLOSER THAN 5/8 INCH TO FACE OF STUD. GRADE z V ,n 1- . * o --1 1 M Q) M iT W � .g ♦♦. `n w E • ® kn Z � y o 0 yn � L_ z° 00 ♦ cv �a 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. Plan No: L2M-2385-2R Date: 12-15-21 r� UPPER FLOOR ELECTRICAL 1/4 11 /41I = I'—O II I i i MAIN FLOOR ELEGTR I GAL 1/411 = I 1-0 11 INTERIOR STAIRWAY ILLUMINATION PER SEC R303.7 I INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN I FOOT-CANDLE MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS PROVIDED. XTERIOR STAIRWAY ILLUMINATION PER SEC R3038 I EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY. STAIRWAY ILLUMINATION SHALL RECEIVE PRIMARY POWER FROM THE BUILDING WIRING. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. COPYRIGHT 2010 Landmark Design Inc. ALL RIGHTS MSE"D ELECTRICAL KEPI' OVERHEAD CAN OUTLET DUPLEX OUTLET 220V OUTLET COMBO. EXT. FAN (VTOS) t LIGHT COMBO SMOKE ALARM - CARBON MONO. DET. e 110 V W/ BATTERY C BACKUP GABLE T.V. JACK PHONE UNDER COUNTER LIGHTS GAS OUTLET HOSE BIBS EXT. FAN VTOS W .:. a ♦♦♦ y � oN0 � QCAz00 1-4 ♦ N N O �a 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed to be marketed throughout many municipalities. The purchaser must verify compliance with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic— ensed builder and struct— ural engineer for compli— ance to specific site con— ditions. 4. These plans should not be altered by other than a qualified designer, archi— tect, or structural engineer. Plan No: L2M-2385-2R Date: 12-15-21 Plan No: L2M-2385 Date: 6-21-21 G=;ENE,4L 5TfRUCTUIRAL NOTES V STEM WALL ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION, WITH WASHINGTON STATE AMENDMENTS. DESIGN LOADS: ROOF LIVE LOAD 25 PSF (SNOW) DEAD LOAD 15 PSF FLOOR LIVE LOAD 40 PSF (RESIDENTIAL) 60 PSF (DECKS) DEAD LOAD 10 PSF WIND BASIC WIND SPEED 110 MPH (3 SECOND GUST, ULTIMATE LOAD) RISK CATAGORY II, EXPOSURE B, Kz, = 1.0 SEISMIC EQUIVALENT LATERAL FORCE PROCEDURE BEARING WALL SYSTEM (LIGHT -FRAMED WALLS) SITE CLASS: D SEISMIC DESIGN CATAGORY: D $s = 1B - IBC FIGURE 161330) SDs = 1.0, le = 1.0, R=6.5 CS = 0.154 INSPECTIONS: NO SPECIAL INSPECTIONS ARE REQUIRED. NOTIFY THE BUILDING DEPARTMENT FOR INSPECTIONS REQUIRED BY LOCAL ORDINANCE. ALL PREPARED SOIL BEARING SURFACES SHALL BE INSPECTED BY A SOILS ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL. FOUNDATIONS: PLACE FOOTINGS ON NATIVE OR COMPACTED SOIL WITH 1,500 PSF BEARING CAPACITY (ASSUMED). BOTTOM OF EXTERIOR FOOTINGS SHALL BE MINIMUM 1'-6" BELOW OUTSIDE FINISHED GRADE. BACKFILL WALLS WITH A WELL DRAINING MATERIAL FREE OF ORGANIC OBJECTS OR DEBRIS. CONCRETE: THE SELECTION OF MATERIALS FOR AND THE MIXING AND PLACING OF ALL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, 2018 EDITION. MATERIALS SHALL BE PROPORTIONED TO PRODUCE A DENSE, WORKABLE MIX HAVING A MAXIMUM SLUMP OF 4 INCHES WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER USE MINIMUM F'c = 3,000 PSI WITH 5.5 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A MAXIMUM OF 52 GALLONS OF WATER PER 94 LB SACK OF CEMENT. ALL CONCRETE SHALL CONTAIN AN AIR ENTRAINING AGENT. THE AMOUNT OF ENTRAINED AIR SHALL BE 41i251. ±1.5511- BY VOLUME. MAXIMUM SIZE OF AGGREGATE IS 11/2 ". ALL CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR EXPANSION JOINTS UNLESS SHOWN OTHERWISE. CONCRETE PURVEYORS/SUPPLIERS DELIVERY OR BATCH TICKET TO BE ON JOB SITE FOR BUILDING INSPECTOR VERIFICATION. REINFORCING STEEL: ALL REINFORCING STEEL SHALL BE MINIMUM GRADE 60 (Fy = 60,000 PSI) DEFORMED BARS IN ACCORDANCE WITH ASTM SPECIFICATION A-615. LAP ALL SPLICES 32 BAR DIAMETERS OR 1'-6" MINIMUM UNLESS OTHERWISE SHOWN. PROVIDE ELBOW BARS (32 DIA.) TO LAP HORIZONTAL STEEL AT COMERS AND INTERSECTIONS IN FOOTINGS AND WALLS. REINFORCEMENT SHALL BE ACCURATELY PLACED AND ADEQUATELY SUPPORTED BY APPROVED CHAIRS, SPACERS, OR TIES AND SECURED IN PLACE DURING GROUT OR CONCRETE PLACEMENT. MINIMUM CONCRETE COVER FOR REINFORCING STEEL: USE SLAB AND WALL BARS: INTERIOR FACES EXPOSED TO WEATHER OR EARTH FOOTING BARS PROTECTION 11,2" 1'/2" (15 AND SMALLER) 2" (*6 AND LARGER) 311 TIMBER: ALL LUMBER SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: BEAMS DM OR BETTER POSTS DF*2 OR BETTER 2x FRAMING HF*2 OR BETTER ALL 2x TIMBER SHALL BE KILN DRIED. ALL GRADES SHALL CONFORM TO "WWPA GRADING RULES FOR WESTERN LUMBER", LATEST EDITION. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA UI. RE -TREAT ALL CUT ENDS, NOTCHES, AND DRILLED HOLES IN ACCORDANCE WITH AWPA M4. MAINTAIN MINIMUM 6" CLEAR BETWEEN WOOD AND EXPOSED EARTH. MAINTAIN 8" CLEAR BETWEEN EXPOSED EARTH AND NON -TREATED WOOD AT EXTERIOR FOUNDATION WALLS. ALL NAILS SHALL BE GALVANIZED BOX OR COMMON NAILS. FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL IN ACCORDANCE WITH SECTION IBC 2304.10.5. ALL MINIMUM NAILING SHALL BE PER IBC TABLE 2304.10.1 U.N.O. MACHINE BOLTS TO BE A-301. BOLT HEADS AND NUTS BEARING AGAINST WOOD SHALL BE PROVIDED WITH STANDARD CUT WASHERS. MISCELLANEOUS HANGERS TO BE 'SIMPSON' OR ICC APPROVED EQUAL. ALL HANGERS TO BE FASTENED TO WOOD WITH PROPER NAILS AND ALL HOLES SHALL BE NAILED. GLUED LAMINATED WOOD MEM5ER5: GLUED LAMINATED WOOD BEAMS (GLB) TO BE IN ACCORDANCE WITH ANSI/AITC STANDARD A190.1, AMERICAN NATIONAL STANDARD FOR STRUCTURAL GLUED LAMINATED TIMBER USE STRESS GRADE COMBINATION 24F-V4 (Fb = 2,400 PSI) FOR SIMPLE SPANS AND 24F-V8 FOR CANTILEVER AND CONTINUOUS SPANS. SIMPLE SPANS SHALL BE CAMBERED ON A 3500' RADIUS UN.O. GLUE SHALL BE CASEIN WITH MOLD INHIBITOR UNLESS OTHERWISE SPECIFIED, SEALER SHALL BE APPLIED TO ENDS OF ALL MEMBERS. BOTTOM LAMINATION TO BE FREE OF UN60UND KNOTS LARGER THAN 11/2" DIAMETER AITC STAMP AND CERTIFICATION REQUIRED. RREFARRICATED JOISTS: JOISTS SHALL BE AS NOTED ON THE PLANS AND AS MANUFACTURED BY TRUSS JOIST WEYERHAEUSER OR APPROVED EQUIVALENT. JOISTS TO BE ERECTED IN ACCORDANCE WITH THE PLANS AND THE MANUFACTURER'S DRAWINGS AND INSTALLATION INSTRUCTIONS. CONSTRUCTION LOADS BEYOND THE DESIGN LOADS ARE NOT PERMITTED. PROVIDE ERECTION BRACING UNTIL SHEATHING MATERIAL HAS BEEN INSTALLED. PROVIDE SOLID BLOCKING AT CONCENTRATED LOADS FROM ABOVE AND WEB STIFFENERS PER MANUFACTURER'S DIRECTIONS. JOIST HANGERS TO BE SIZED AND PROVIDED BY THE MANUFACTURER OR SUPPLIER LAMINATED VENEER LUMBER (LVL): LAMINATED VENEER LUMBER (LVL) TO BE BY TRUSS JOIST WEYERHAEUSER (MICROLAM - Fb = 2,600 PSI, E = 1,900,000 PSI). MATERIAL SHALL BE DESIGNED 4 MANUFACTURED TO THE STANDARDS SET FORTH IN NER-481 OR CCMC REPORT NO.08615-R. BEARING LENGTH SHALL NOT BE LESS THAN 11/2 ". DO NOT CUT OR NOTCH BEAMS WITHOUT PRIOR APPROVAL OR ENGINEER HEEL CUTS SHALL NOT OVERHANG INSIDE FACE OF SUPPORTING MEMBER REARING WALL FRAMING: ALL DOOR AND WINDOW HEADERS NOT CALLED OUT OR OTHERWISE NOTED ON THE PLANS SHALL BE 4x8 DF2 WITH ONE CRIPPLE AND ONE STUD EACH END FOR OPENINGS 5'-0" OR LESS AND TWO CRIPPLES AND ONE STUD FOR OPENINGS MORE THAN 5'-0" WIDE. ALL COLUMNS NOT CALLED OUT ON THE PLANS SHALL BE TWO (2) STUDS. SPIKE LAMINATED COLUMNS TOGETHER WITH 16d 61 12" O.C. STAGGERED. STAGGER SPLICES AT TOP PLATES MINIMUM 48" AND NAIL WITH l(ocls 8" O.C. SHEAR WALLS: ALL SHEAR WALL SHEATHING NAILING AND ANCHORS SHALL BE AS DETAILED ON THE DRAWINGS AND NOTED IN THE SHEAR WALL SCHEDULE. USE APA RATED SHEATHING (24/1(o) WITH A MINIMUM PANEL EDGE NAILING OF 8d 11 6" O.C. UNLESS NOTED OTHERWISE. ALL SHEAR WALL NAILING SHALL BE COMMON WIRE OR GALVANIZED BOX NAILS. FASTENERS IN PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL. BLOCK ALL UNSUPPORTED PANEL EDGES. DESIGNATED 3x FRAMING MAY BE (2) 2x MEMBERS FACE -NAILED WITH 16d 6 12" O.C. STAGGERED. ALL HEADERS SHALL HAVE STRAP CONNECTORS TO THE TOP PLATE AT EACH END WHEN THE HEADER INTERRUPTS THE TOP PLATE. USE 'SIMPSON' L5TA24 CONNECTOR U.N.O. FLOOR AND ROOF FRAMING: DIMENSIONAL FRAMING MEMBERS SHALL BE FREE OF SPLITS, CHECKS, AND SHAKES. PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE LENGTH AND ALL AROUND ALL OPENINGS IN FLOORS AND ROOFS U.N.O. PROVIDE SOLID BLOCKING AT RIM JOISTS BELOW CONCENTRATED LOADS FROM ABOVE. APPLY 3/4" RATED SHEATHING (40/20) GLUED AND NAILED TO FLOOR FRAMING MEMBERS WITH 8d COMMON OR GALVANIZED BOX NAILS AT 6" O.C. AT ALL SUPPORTED EDGES AND 8d COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT INTERIOR SUPPORTS. APPLY 112" RATED SHEATHING (24/1(o) ON ROOF NAILED TO STIFFENERS OR RAFTERS WITH 8d COMMON OR GALVANIZED BOX NAILS AT 6" O.C. AT SUPPORTED EDGES AND Sd COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT INTERIOR SUPPORTS. LAY SHEATHING PERPENDICULAR TO FRAMING AND STAGGER PANEL EDGES. FLOOR AND ROOF TRUSSES: TRUSSES TO BE DESIGNED AND SUPPLIED IN ACCORDANCE WITH ANSI/TPI 1-2014. THE TRUSS CALCULATION PACKAGE SHALL BE PREPARED UNDER THE DIRECT SUPERVISION OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. THE TRUSS ENGINEER SHALL ASSUME ALL RESPONSIBILITY FOR THE WORK OF ALL SUBORDINATES INVOLVED IN THE PREPARATION OF THE TRUSS PLACEMENT PLAN AND TRUSS DESIGN DRAWINGS. EACH TRUSS SHALL BE PLANT FABRICATED AND SHALL BEAR THE QUALITY CONTROL STAMP, MANUFACTURER'S NAME, DESIGN LOAD, AND MAXIMUM SPACING. ALL MECHANICAL CONNECTORS SHALL BE ICC APPROVED. LOADS SHALL BE IN ACCORDANCE WITH THE RECOMMENDED DESIGN LOADS AND IBC CHAPTER 16. MANUFACTURER SHALL PROVIDE ALL TRUSS -TO -TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE BUILDING DEPARTMENT FOR APPROVAL AND MAINTAIN DRAWINGS ON SITE FOR INSPECTION. CONTRACTOR TO VERIFY ALL TRUSS LENGTHS PRIOR TO FABRICATION AND INSTALLATION. TRUSSES SHALL BE BRACED TO PREVENT ROTATION AND PROVIDE LATERAL STABILITY IN ACCORDANCE WITH THE CONSTRUCTION DRAWINGS AND INDIVIDUAL TRUSS DRAWINGS. NO TRUSS SHALL BE ALTERED WITHOUT PRIOR WRITTEN CONSENT OF THE TRUSS DESIGNER AND ENGINEER OF RECORD. GENERAL CONSTRUCTION NOTES: ALL CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE (IBC), 2016 EDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND METHODS, TECHNIQUES, AND SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE SPECIFIED WORK THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ALL CONDITIONS AT THE JOB SITE INCLUDING BUILDING AND SITE CONDITIONS BEFORE COMMENCING WORK AND BE RESPONSIBLE FOR SAME. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING DEPARTMENT FOR ALL BUILDING DEPARTMENT REQUIRED INSPECTIONS. DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. THE DETAILS SHOWN ARE TYPICAL AND SHALL BE USED FOR LIKE OR SIMILAR CONDITIONS NOT SHOWN. VARIATIONS AND MODIFICATIONS TO WORK SHOWN ON THE DRAWINGS SHALL NOT BE CARRIED OUT WITHOUT THE WRITTEN PERMISSION FROM THE ARCHITECT OR ENGINEER 5NE,4R UJ,4LL SCHEDULE - MARK MINIMUM SHEATHING (1) SHEATHING NAILING (1) ANCHOR 5OLT5 (3) REMARKS (4, 5) 1/2" CDX ad 61 6" O.C. 5/8" a 60" O.G. Qall = 230 PLF OR OSB '/2" CDX 8d a 4" O.C. 5/8" 61 32" O.C. Qall = 350 PLF OR OSB '/2" CDX 8d a 3" O.C. 5i8" a 1(o" O.C. QaII = 450 PLF C OR OSB USE 3x STUDS AT ABUTTING PANEL EDGES 4 STAGGER NAILS R SEE DETAIL 12 / 52.0 FOR CONSTRUCTION NOTES 1) ALL WALLS DESIGNATED" D" ARE SHEAR WALLS. EXTERIOR WALLS SHALL BE SHEATHED WITH RATED SHEATHING (24/0) AND NAILED AT ALL PANEL EDGES (BLOCKED) PER SCHEDULE. NAILING AT T1-11 PANELS SHALL BE THROUGH EACH EDGE OF EACH PANEL. NAILING AT INTERMEDIATE FRAMING TO BE AT 12" O.C. NAILING NOT CALLED OUT SHALL BE PER IBC TABLE 2304.10.1. NAILING IN PRESERVATIVE TREATED LUMBER SHALL BE STAINLESS STEEL OR OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL PER ASTM AI53. 2) HOLDOWNS AND OTHER FRAMING HARDWARE BY SIMPSON STRONG TIE OR ICC APPROVED EQUAL TO BE USED PER PLAN. ENDS OF SHEAR WALLS SHALL USE DOUBLE STUDS MINIMUM. 3) USE MINIMUM OF TWO (2) BOLTS PER SILL PIECE WITH ONE BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 5" FROM EACH END OF EACH PIECE. EMBED BOLTS MINIMUM OF 1" INTO CONCRETE. WASHERS TO BE 3" x 3" x 1/4" PER IBC SECTION 230832 AND OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL IN ACCORDANCE WITH ASTM AI53. 4) ALLOWABLE LOADS ARE PERMITTED TO BE INCREASED 40% FOR WIND DOvPG1QFIR) ACCORDANCE WITH AF4PA SDPWS TABLE 43A. 5) DESIGNATED 3x STUDS MAY BE (2) 2x MEMBERS FACE -NAILED WITH 16d a 12" O.C. STAGGERED. LSTA36 - NDR 4 SILL TO 3x BLOCKING. P✓ (TYP. 2 PLACES) LSTA24 - BEAM G O TOP PLATE �/z x 109:rjLt5"/2 -- x 15 GLB -� LSTA36 - MDR 4 SILL CD TO 3x BLOCKING. � (T1 P. 2 PLACES) x 3�sx15 4x12.r Ln - NTS20 - BEAM TO TOP PLATE MAIN FLOOR A = 1,063 SQ FT A = 391 SQ FT ' �I 51/2 x 13B GLIB P/4X18LVL ,Lu R � rYP. of 2) 31,� x 12 GLB a a 4 4 a ° ADD 04 f BAR FOR a STEPS EXCEEDING 2'. Sll ° ° 2 MAX. 1 MAX. CONTINUOUS FTG. MINIMUM REINFORCEMENT 1 STEPPED FOOTING DETAIL SI.O SCALE: 34' - 1'-0' MSTC40 HOLDOWN. ALIGN WITH EMBEDDED STHD TYPE 14OLDOU N BELOW. SHEATHING 4 NAILING PER PLAN. SPLICE TO OCCUR ON COMMMON MEMBER OR BLOCKING SHEATHING 4 NAILING PER PLAN. MATCH WALL ABOVE UNA. in FINISH GRADE lbd a 16" O.C. SOLE PLATE NAILING. 3/4" SUBFLOOR �(3) Sd JOIST -TO -TOP PLATE UNA. MAINTAIN "MIN.11/z" END DISTANCE. z x 6 STUD a 16" O.C. USE -DBL STUD a ENDS OF SHEAR WALLS 4 HOLDOWNS. 6'-0" 2x PT SILL w/ k8"#ANCHOR MAX. -BOLT 4 3" x 3" x 1/4" WASHER AT V-0" O.C. UNA. (ALT. MASA a 48" O.C) STHD TYPE HOLDOWN PER PLAN. -04 BAR a 10" O.C. - HORIZ (36° 04 BAR s 16" O C. - VERT. FINISH GRADE 04 BAR CONTINUOUS (18" MIN ) 4� (TYP OF 2) D 0 e D � 2 CRIPPLE WALL WITIH BACKFILL FOUNDATION SI.O SCALE. 34' - I'-0' SHEATHING 4 NAILING PER PLAN OR SCHEDULE 16d a 8" O.C. SOLE PLATE NAILING. 3d a 6" O.C. UNO /--SUBFLOOR PER PLAN JOIST PER PLAN BEAM PER PLAN s SHEAR WALL FRAMING AT FLUSH BEAM 51.0 SCALE: %" - 1'-0' COPYRIGHT 2021, SEGA ENGINEERS p 'an co p w W � to .01 �o m o U b � U q . r..q m co 0 to v � ri a b a cq cq w w co w cq cq CID � N II u III � Lu 1 "014'arm"Al 'alA- JOB 10-09l OIL U STEM WALL ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION, WITH WASHINGTON STATE AMENDMENTS. DESIGN LOADS: ROOF LIVE LOAD 25 PSF (SNOW) DEAD LOAD 15 PSF FLOOR LIVE LOAD 40 PSF (RESIDENTIAL) 60 PSF (DECKS) DEAD LOAD 10 PSF WIND BASIC WIND SPEED 110 MPH (3 SECOND GUST, ULTIMATE LOAD) RISK CATAGORY II, EXPOSURE B, Kz, = 1.0 SEISMIC EQUIVALENT LATERAL FORCE PROCEDURE BEARING WALL SYSTEM (LIGHT -FRAMED WALLS) SITE CLASS: D SEISMIC DESIGN CATAGORY: D $s = 1B - IBC FIGURE 161330) SDs = 1.0, 1E = 1.0, R=6.5 CS = 0.154 INSPECTIONS: NO SPECIAL INSPECTIONS ARE REQUIRED. NOTIFY THE BUILDING DEPARTMENT FOR INSPECTIONS REQUIRED BY LOCAL ORDINANCE. ALL PREPARED SOIL BEARING SURFACES SHALL BE INSPECTED BY A SOILS ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL. FOUNDATIONS: PLACE FOOTINGS ON NATIVE OR COMPACTED SOIL WITH 1,500 PSF BEARING CAPACITY (ASSUMED). BOTTOM OF EXTERIOR FOOTINGS SHALL BE MINIMUM 1'-6" BELOW OUTSIDE FINISHED GRADE. BACKFILL WALLS WITH A WELL DRAINING MATERIAL FREE OF ORGANIC OBJECTS OR DEBRIS. CONCRETE: THE SELECTION OF MATERIALS FOR AND THE MIXING AND PLACING OF ALL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, 2018 EDITION. MATERIALS SHALL BE PROPORTIONED TO PRODUCE A DENSE, WORKABLE MIX HAVING A MAXIMUM SLUMP OF 4 INCHES WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER USE MINIMUM F'c = 3,000 PSI WITH 5.5 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A MAXIMUM OF 52 GALLONS OF WATER PER 94 LB SACK OF CEMENT. ALL CONCRETE SHALL CONTAIN AN AIR ENTRAINING AGENT. THE AMOUNT OF ENTRAINED AIR SHALL BE 41/251. ±1.5511. BY VOLUME. MAXIMUM SIZE OF AGGREGATE IS 11/2 ". ALL CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR EXPANSION JOINTS UNLESS SHOWN OTHERWISE. CONCRETE PURVEYORS/SUPPLIERS DELIVERY OR BATCH TICKET TO BE ON JOB SITE FOR BUILDING INSPECTOR VERIFICATION. REINFORCING STEEL: ALL REINFORCING STEEL SHALL BE MINIMUM GRADE 60 (Fy = 60,000 PSI) DEFORMED BARS IN ACCORDANCE WITH ASTM SPECIFICATION A-615. LAP ALL SPLICES 32 BAR DIAMETERS OR 1'-6" MINIMUM UNLESS OTHERWISE SHOWN. PROVIDE ELBOW BARS (32 DIA.) TO LAP HORIZONTAL STEEL AT COMERS AND INTERSECTIONS IN FOOTINGS AND WALLS. REINFORCEMENT SHALL BE ACCURATELY PLACED AND ADEQUATELY SUPPORTED BY APPROVED CHAIRS, SPACERS, OR TIES AND SECURED IN PLACE DURING GROUT OR CONCRETE PLACEMENT. MINIMUM CONCRETE COVER FOR REINFORCING STEEL: USE SLAB AND WALL BARS: INTERIOR FACES EXPOSED TO WEATHER OR EARTH FOOTING BARS PROTECTION 11/2 " 1'/2" (15 AND SMALLER) 2" (*6 AND LARGER) 311 TIMBER: ALL LUMBER SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: BEAMS DF*2 OR BETTER POSTS DF*2 OR BETTER 2x FRAMING HF*2 OR BETTER ALL 2x TIMBER SHALL BE KILN DRIED. ALL GRADES SHALL CONFORM TO "WWPA GRADING RULES FOR WESTERN LUMBER", LATEST EDITION. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA UI. RE -TREAT ALL CUT ENDS, NOTCHES, AND DRILLED HOLES IN ACCORDANCE WITH AWPA M4. MAINTAIN MINIMUM 6" CLEAR BETWEEN WOOD AND EXPOSED EARTH. MAINTAIN 8" CLEAR BETWEEN EXPOSED EARTH AND NON -TREATED WOOD AT EXTERIOR FOUNDATION WALLS. ALL NAILS SHALL BE GALVANIZED BOX OR COMMON NAILS. FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL IN ACCORDANCE WITH SECTION IBC 2304.10.5. ALL MINIMUM NAILING SHALL BE PER IBC TABLE 2304.10.1 U.N.O. MACHINE BOLTS TO BE A-301. BOLT HEADS AND NUTS BEARING AGAINST WOOD SHALL BE PROVIDED WITH STANDARD CUT WASHERS. MISCELLANEOUS HANGERS TO BE 'SIMPSON' OR ICC APPROVED EQUAL. ALL HANGERS TO BE FASTENED TO WOOD WITH PROPER NAILS AND ALL HOLES SHALL BE NAILED. GLUED LAMINATED WOOD MEMBERS: GLUED LAMINATED WOOD BEAMS (GLB) TO BE IN ACCORDANCE WITH ANSI/AITC STANDARD A190.1, AMERICAN NATIONAL STANDARD FOR STRUCTURAL GLUED LAMINATED TIMBER USE STRESS GRADE COMBINATION 24F-V4 (Fb = 2,400 PSI) FOR SIMPLE SPANS AND 24F-V8 FOR CANTILEVER AND CONTINUOUS SPANS. SIMPLE SPANS SHALL BE CAMBERED ON A 3500' RADIUS UN.O. GLUE SHALL BE CASEIN WITH MOLD INHIBITOR UNLESS OTHERWISE SPECIFIED, SEALER SHALL BE APPLIED TO ENDS OF ALL MEMBERS. BOTTOM LAMINATION TO BE FREE OF UNSOUND KNOTS LARGER THAN 1/2" DIAMETER AITC STAMP AND CERTIFICATION REQUIRED. PREFABRICATED JOISTS: JOISTS SHALL BE AS NOTED ON THE PLANS AND AS MANUFACTURED BY TRUSS JOIST WEYERHAEUSER OR APPROVED EQUIVALENT. JOISTS TO BE ERECTED IN ACCORDANCE WITH THE PLANS AND THE MANUFACTURER'S DRAWINGS AND INSTALLATION INSTRUCTIONS. CONSTRUCTION LOADS BEYOND THE DESIGN LOADS ARE NOT PERMITTED. PROVIDE ERECTION BRACING UNTIL SHEATHING MATERIAL HAS BEEN INSTALLED. PROVIDE SOLID BLOCKING AT CONCENTRATED LOADS FROM ABOVE AND WEB STIFFENERS PER MANUFACTURER'S DIRECTIONS. JOIST HANGERS TO BE SIZED AND PROVIDED BY THE MANUFACTURER OR SUPPLIER LAMINATED VENEER LUMBER (LVL): LAMINATED VENEER LUMBER (LVL) TO BE BY TRUSS JOIST WEYERHAEUSER (MICROLAM - Fb = 2,600 PSI, E = 1,900,000 PSI). MATERIAL SHALL BE DESIGNED 4 MANUFACTURED TO THE STANDARDS SET FORTH IN NER-481 OR CCMC REPORT NO.08675-R. BEARING LENGTH SHALL NOT BE LESS THAN I1/2 ". DO NOT CUT OR NOTCH BEAMS WITHOUT PRIOR APPROVAL OR ENGINEER HEEL CUTS SHALL NOT OVERHANG INSIDE FACE OF SUPPORTING MEMBER BEARING WALL FRAMING: ALL DOOR AND WINDOW HEADERS NOT CALLED OUT OR OTHERWISE NOTED ON THE PLANS SHALL BE 4x8 DF2 WITH ONE CRIPPLE AND ONE STUD EACH END FOR OPENINGS 5'-0" OR LESS AND TWO CRIPPLES AND ONE STUD FOR OPENINGS MORE THAN 5'-0" WIDE. ALL COLUMNS NOT CALLED OUT ON THE PLANS SHALL BE TWO (2) STUDS. SPIKE LAMINATED COLUMNS TOGETHER WITH 16d 4a 12" O.C. STAGGERED. STAGGER SPLICES AT TOP PLATES MINIMUM 48" AND NAIL WITH lbd is all O.C. SHEAR WALLS: ALL SHEAR WALL SHEATHING NAILING AND ANCHORS SHALL BE AS DETAILED ON THE DRAWINGS AND NOTED IN THE SHEAR WALL SCHEDULE. USE APA RATED SHEATHING (24/1(o) WITH A MINIMUM PANEL EDGE NAILING OF 8d 4v 6" O.C. UNLESS NOTED OTHERWISE. ALL SHEAR WALL NAILING SHALL BE COMMON WIRE OR GALVANIZED BOX NAILS. FASTENERS IN PRESERVATIVE -TREATED WOOD SHALL BE OF NOT -DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL. BLOCK ALL UNSUPPORTED PANEL EDGES. DESIGNATED 3x FRAMING MAY BE (2) 2x MEMBERS FACE -NAILED WITH 16d 6 12" O.C. STAGGERED. ALL HEADERS SHALL HAVE STRAP CONNECTORS TO THE TOP PLATE AT EACH END WHEN THE HEADER INTERRUPTS THE TOP PLATE. USE 'SIMPSON' L5TA24 CONNECTOR UN.O. FLOOR AND ROOF FRAMING: DIMENSIONAL FRAMING MEMBERS SHALL BE FREE OF SPLITS, CHECKS, AND SHAKES. PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE LENGTH AND ALL AROUND ALL OPENINGS IN FLOORS AND ROOFS U.N.O. PROVIDE SOLID BLOCKING AT RIM JOISTS BELOW CONCENTRATED LOADS FROM ABOVE. APPLY 3/4" RATED SHEATHING (40/20) GLUED AND NAILED TO FLOOR FRAMING MEMBERS WITH ad COMMON OR GALVANIZED BOX NAILS AT 6" O.C. AT ALL SUPPORTED EDGES AND ad COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT INTERIOR SUPPORTS. APPLY 1/2" RATED SHEATHING (24/1(o) ON ROOF NAILED TO STIFFENERS OR RAFTERS WITH 8d COMMON OR GALVANIZED BOX NAILS AT b" O.C. AT SUPPORTED EDGES AND Sd COMMON OR GALVANIZED BOX NAILS AT 12" O.C. AT INTERIOR SUPPORTS. LAY SHEATHING PERPENDICULAR TO FRAMING AND STAGGER PANEL EDGES. FLOOR AND ROOF TRUSSES: TRUSSES TO BE DESIGNED AND SUPPLIED IN ACCORDANCE WITH ANSI/TPI 1-2014. THE TRUSS CALCULATION PACKAGE SHALL BE PREPARED UNDER THE DIRECT SUPERVISION OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. THE TRUSS ENGINEER SHALL ASSUME ALL RESPONSIBILITY FOR THE WORK OF ALL SUBORDINATES INVOLVED IN THE PREPARATION OF THE TRUSS PLACEMENT PLAN AND TRUSS DESIGN DRAWINGS. EACH TRUSS SHALL BE PLANT FABRICATED AND SHALL BEAR THE QUALITY CONTROL STAMP, MANUFACTURER'S NAME, DESIGN LOAD, AND MAXIMUM SPACING. ALL MECHANICAL CONNECTORS SHALL BE ICC APPROVED. LOADS SHALL BE IN ACCORDANCE WITH THE RECOMMENDED DESIGN LOADS AND IBC CHAPTER 16. MANUFACTURER SHALL PROVIDE ALL TRUSS -TO -TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE BUILDING DEPARTMENT FOR APPROVAL AND MAINTAIN DRAWINGS ON SITE FOR INSPECTION. CONTRACTOR TO VERIFY ALL TRUSS LENGTHS PRIOR TO FABRICATION AND INSTALLATION. TRUSSES SHALL BE BRACED TO PREVENT ROTATION AND PROVIDE LATERAL STABILITY IN ACCORDANCE WITH THE CONSTRUCTION DRAWINGS AND INDIVIDUAL TRUSS DRAWINGS. NO TRUSS SHALL BE ALTERED WITHOUT PRIOR WRITTEN CONSENT OF THE TRUSS DESIGNER AND ENGINEER OF RECORD. GENERAL CONSTRUCTION NOTES: ALL CONSTRUCTION SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE (IBC), 2016 EDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND METHODS, TECHNIQUES, AND SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE SPECIFIED WORK THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ALL CONDITIONS AT THE JOB SITE INCLUDING BUILDING AND SITE CONDITIONS BEFORE COMMENCING WORK AND BE RESPONSIBLE FOR SAME. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS AND STIFFENERS HAVE BEEN INSTALLED. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING DEPARTMENT FOR ALL BUILDING DEPARTMENT REQUIRED INSPECTIONS. DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. THE DETAILS SHOWN ARE TYPICAL AND SHALL BE USED FOR LIKE OR SIMILAR CONDITIONS NOT SHOWN. VARIATIONS AND MODIFICATIONS TO WORK SHOWN ON THE DRAWINGS SHALL NOT BE CARRIED OUT WITHOUT THE WRITTEN PERMISSION FROM THE ARCHITECT OR ENGINEER 5NE,4R UJ,4LL SCHEDULE - MARK MINIMUM SHEATHING (1) SHEATHING NAILING (1) ANCHOR BOLTS (3) REMARKS (4, 5) 1/2" CDX ad 61 6" O.C. 5/8" a 60" O.C. Qa11 = 230 PLF OR OSB 1/2" CDX 8d G 4" O.C. 5/8" ,9 32" O.C. Qa11 = 350 PLF OR OSB '/2" CDX ad a 3" O.C. 5/8" a 1(0" O.C. QaII = 450 PLF C OR OSB USE 3x STUDS AT ABUTTING PANEL EDGES 4 STAGGER NAILS R SEE DETAIL 12 / 52.0 FOR CONSTRUCTION NOTES 1) ALL WALLS DESIGNATED" D" ARE SHEAR WALLS. EXTERIOR WALLS SHALL BE SHEATHED WITH RATED SHEATHING (24/0) AND NAILED AT ALL PANEL EDGES (BLOCKED) PER SCHEDULE. NAILING AT T1-11 PANELS SHALL BE THROUGH EACH EDGE OF EACH PANEL. NAILING AT INTERMEDIATE FRAMING TO BE AT 12" O.C. NAILING NOT CALLED OUT SHALL BE PER IBC TABLE 2304.10.1. NAILING IN PRESERVATIVE TREATED LUMBER SHALL BE STAINLESS STEEL OR OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL PER ASTM AI53. 2) HOLDOWNS AND OTHER FRAMING HARDWARE BY SIMPSON STRONG TIE OR ICC APPROVED EQUAL TO BE USED PER PLAN. ENDS OF SHEAR WALLS SHALL USE DOUBLE STUDS MINIMUM. 3) USE MINIMUM OF TWO (2) BOLTS PER SILL PIECE WITH ONE BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 5" FROM EACH END OF EACH PIECE. EMBED BOLTS MINIMUM OF 1" INTO CONCRETE. WASHERS TO BE 3" x 3" x 1/4" PER IBC SECTION 230832 AND OF HOT -DIPPED ZINC -COATED GALVANIZED STEEL IN ACCORDANCE WITH ASTM AI53. 4) ALLOWABLE LOADS ARE PERMITTED TO BE INCREASED 40% FOR WIND D96PG1QFIR) ACCORDANCE WITH AF4PA SDPWS TABLE 43A. 5) DESIGNATED 3x STUDS MAY BE (2) 2x MEMBERS FACE -NAILED WITH 16d 6 12" O.C. STAGGERED. L — — — — — — L LSTA36 - NDR 4 SILL TO 3x BLOCKING. ITYP. 2 PLACES) LSTA24 - BEAM C TO TOP PLATE �/2 x 105:rjLj -- 51/2 x 15 GLB -� LSTA36 - HDR 4 SILL TO 3x BLOCKING. CD � (T1'P. 2 PLACES) B "I Ax15B 4x12 .r - Ln - - HT520 - BEAM TO TOP PLATE MAIN FLOOR A = 1,063 SQ FT A = 391 SQ FT ' �I 51/2 x 135 GLB _ P/4X18LVL El W R iR ts rYP. of 2) 31/2 x 12 GLB a a 4 4 a a AD4)44 AR FOR STEEDING 2'. $�� ° ° 2 MAX. 1 MAX. CONTINUOUS FTG. MINIMUM REINFORCEMENt 1 STEPPED FOOTING DETAIL SI.O SCALE: 34. - 1'-0• MSTC40 HOLDOWN. ALIGN WITH EMBEDDED STHD TYPE 14OLDOU N BELOW. SHEATHING 4 NAILING PER PLAN. SPLICE t0 OCCUR ON COMMMON MEMBER OR BLOCKING SHEATHING 4 NAILING PER PLAN. MATCH WALL ABOVE UNA. In FINISH GRADE lbd s I6" O.C. SOLE PLATE NAILING. 3/4" SUBFLOOR �(3) 8d JOIST -TO -TOP PLATE UNA. MAINTAIN "MIN. II/Q" END DISTANCE. z x 6 STUD + 16" O.C. USE -DBL STUD ® ENDS OF SHEAR WALLS 4 HOLDOWNS. 6'-0" 2x PT SILL w/ 5/&"4ANCHOR MAX. -BOLT 4 3" x 3" x 1/4" WASHER AT 5'-0" O.C. UNA. (ALT. MASA 9 48" O.C) STHD TYPE HOLDOWN PER PLAN. -04 BAR + 10" O:C. - HORIZ (36" 04 BAR s 16" OTC. - VERT. FINISH GRADE 04 BAR CONTINUOUS (18" MIN ) 4� (TYP OF 2) D 0 0 D � 2 CRIPPLE WALL WITIH BACKFILL FOUNDATION SI.O SCALE: 34" ■ P-0' SHEATHING 4 NAILING PER PLAN OR SCHEDULE Ibd a 6" O.C. SOLE PLATE NAILING. 3d a b" O.G. UNO SUBFLOOR PER PLAN JOIST PER PLAN BEAM PER PLAN 3 SHEAR WALL FRAMING AT FLUSH BEAM 51.0 SCALE: aw , 1'-0" COF''FRIGHT 2021, SEG,4 ENGINEERS N W Z IL O w O Lu 0 p to co p w W � to q �o � a m o U b Q U q � . r..q m co v ILI � rn a b a cq w cq w co w cq cq III -A -q —A f JOB 10-09-1 '/2" RATED SHEATHING ad a 6" O.C. ad Is 6" O.C.(LENGTH OF TRUSS) ''/2" RATED SHEATHING (4" O.C. SIM.) _� RATED SHEATHING l24/16) ad 4" O.C. N STAGGERED SHEATHINGLu PER PLAN. EXTEND OVER H1 FRAMING ANCHOR (L� 2x VENTED BLOCKING. EACH TRUSS. USE H10A-2 MAXIMUM LATERAL 2x BLOCKING AT ad tv 6" O.C. At DBL TRUSS. GABLE END TRUSS. I LOAD IN EITHER TRUSS, PANEL EDGE ad � 4 O.C. � u1 � V = 3,515 LBS. '/2" RATED SHEATHING 2x NAILER w/ 16d U N A35 9 48" O.C. 4 O.C. TO TRUSS DBL 2x TOP PLATE. LAP (USE 24" O.C. AT SIM.) MONO TRUSS PER PLAN GABLE END / HIP MASTER 2x VENTED BLOCKING. TRUSS PER PLAN SPLICE 4'-0" MIN. NAIL w/ 2x BRACE PER TRUSS SUPPLIER END NAIL t0 TRUSS m DBL 2x TOP PLATE. LAP SPLICE 16d 6 6" O.C. STAGGERED. OR � 46" O.C. SECURE w/ TRUSS PER PLAN EACH END w/ (2) ad, 4'-O" MIN. S NAIL w/ 16d -9 4" O.C. A34 EACH END. WALL SHEATHING AND NAILING STAGGERED. ADD LSTA24 TO '/2" PLYWOOD (2�6) w/ (2) ROWS HANGER BY TRUSS SPLICE PER PLAN SHEATHINGS NAILING �112x ad 4" O.C. TO TOP PLATE S SUPPLIER PER PLAN OR SCHEDULE. PER PLAN OR SHEAR FRAMING PER PLAN. Sd ,@ 4" O.C. EDGE NAILING SPLICE TO OCCUR ON COMMON 2x FRAMING PER PLAN. WALL SCHEDULE. (HEADER SIM.) MEMBER OR BLOCKING SHEATHING S NAILING ,� o PER PLAN. w w a .01 an 1 T''FIGAL ROOF FRAMING CONNECTION 2 ROOF FRAMING G,45LE END 3 INTERIOR 5HEAR, WALL TRU55 64 LOWER ROOF FRAMING GA5LE END S2 0 SCALE: I" = I'-0" S2 0 SCALE: I" = I'-0" S2 0 SCALE: I" = I'-0" S2 0 SCALE: I" = I'-0" o U q 1(od 16" O.G. SOLE MSTG HOLDOWN 1(od 8" O.C. SOLE DBL 2x TOP PLATE v o PLATE NAILING. STRAP PER PLAN PLATE NAILING. FLOOR TRUSS PER PLAN 16d 6 4" O.C. SOLE � � a" I (3) 16d TO TRUSS WEB (TYP.) PLATE NAILING. (SIM ONLY) SUBFLOOR PER PLAN 2x RIBBON NAILER (TYP) SUBFLOOR PER PLAN '/2" SHEATHING w/ ad HDR PER PLAN.________________________T_T____------------ __T co o SUBFLOOR PER PLAN I T- ---- bx 2x CONTINUOUS RIBBON (3) Sd JOIST -TO -TOP Sd a 4" O.C. 's 6" O.C. EDGE NAILING. I PLATE UN.O. MAINTAIN SHEATHING S NAILING (NOT'S MANF PANEL) MIN.111/2" ENE) DISTANCE. PER PLAN. PANEL EDGES _ _ MSTC HOLDOUN I TO OCCUR ON COMMON STRAP PER PLAN MEMBER OR BLOCKING. — a i 3x BLOCKING. EXTEND b a j a 4" O.C. 1�_0�� j j (2) BAYS (24" MINIMUM) cQ TRUSS PER PLAN --,I OR TO CORNER cq j SHEATHING S NAILING PER PLAN. ! a ! j j (TYP) SPLICE t0 OCCUR ON COMMON ; ; i___—_—_—_____________i_ TRIMMER STUD(S) 2x FRAMING w/ (3) ' MEMBER OR BLOCKING '/2" SHEATHING INFILL BLOCKING w/ 16d TO TRUSS WEB ! w cQ 'i2" SHEATHING INFILL BLOCKING ad 6 6" O.C. EDGE NAILING OR FLOOR TRUSS w/ Sd ,@ 6" O.C. EDGE NAILING. MANUFACTURED BLOCKING PANEL. 16d �► 4" O.C. KING STUD j PER PLAN (NOT AT MANF. BLOCING PANEL) 2x FRAMING PER PLAN. MSTC HOLDOWN PER PLAN j (BEAM tv SIM.) 2x DBL TOP PLATE. LAP SPLICE 16d 4" O.C. (SIMILAR ONLY) 2x FRAMING PER PLAN. j 4'-0" MIN. S NAIL w/ 16d 'a 4" SHEATHING S NAILING PER O.G. STAGGERED. 2x FRAMING PER PLAN. PLAN OR SCHEDULE. j '/2" RATED SHEATHING S NAILING PER SCHEDULE. LSTA STRAP PER 5 TYPICAL FLOOR FRAMING CONNECTION FLOOR FRAMING CANT. J015T FLOOR FRAMING INTERIOR 5HEAR WALL PLAN (TYP). 2.mSCALE: I' -0 SCALE: I1 0ISCALE: I11 0 II 2x SILL PLATE � 2x BLOCKING w/ (3) ad a _ SHEATHING S NAILING PER PLAN. ad 6" O.C. TOE -NAIL TO 4x BEAM S SPLICE t0 OCCUR ON COMMON �2 RATED SHEATHING 16d � 8 O.C. SOLE S NAILING PER PLAN. PLATE NAILING. (2) ad TO JOISTS. MEMBER OR BLOCKING SUBFLOOR PER PLAN I ' 3x BLOCKING ad � 4" O.C.16d @ 8 O.C. SOLE 2x CONTINUOUS JOIST PER PLAN PLATE NAILING SUBFLOOR PER PLAN (TYP) 2x BLOCKING w/ 16d IV 4" O.C. RIBBON 2x4 w/ (8) 16d AT 8 5HEAR WALL FORCE TRANSFER DETAIL 1/2" SHEATHING SUBFLOOR PER PLAN 2x4 GUSSET EA BEAM PLICE. s2.0 SCALE: I" = r-0�� SIDE w/ (8)16d (NOT A METAL CAP) (ALT. METAL CAP) TRUSS PER PLAN 4x4 Pt POST L5TA24 STRAP (4x6 AT SPLICE) (FAR SIDE) „ + 16 NOTE: MAB ANCHOR 18�� 2x TOP PLATE MINIMUM NAIL SHEATHING TO HDR SEE ARCH FOR FLASHING FLOOR TRUSS (ALT. A34 ANCHOR w/ Sd 3" O.C. EACH WAY. REQUIREMENTS. PER PLAN FLOOR TRUSS PER PLAN TWO SIDES) 12�� MIN. HDR PER PLAN. EXTEND MIN. OVER PANEL TO KING STUD. (6) 16d KING SCUD t0' FTG PER PLAN ° a a a HEADER Y TRUSS SUPPLIER D a «;LUS24 HANGER BY HANGER B TRUSS SUPPLIER BEAM PER PLAN BEAM PER PLAN. FINISH GRADE ° o ' 1 2x KING STUD w/ 2x FASTEN TOP PLATE TO CRIPPLE STUD 9 FLOOR FRAMING CONNECTION '� FLU5H NAM 10 5HEAR WALL FRAMING AT 5E,4M 11 FLOOR FRAMING �AT CRAWL 5P�4CE HEADER w/ (2) ROWS a' s2 m SCALE: I _ I 0 s2 r� SCALE: I - I 0 16d AT 3" O.C. : 4x BLOCKING MIDDLE S2 0 SCALE: I" = I'-0" - " :j. i;i 24" IF REQUIRED./ oo 10'-0" MAX. 16d s 16" O.C. SOLE (8'-0" 's SIM) --- ---'± *! 2x STUD PER PLAN. USE MINIMUM PLATE NAILING. 2x STUD PER PLAN. USE DBL (2) 2x STUD tv ENDS OF SHEAR *j i" RATED SHEATHING (24/0 EXP 1). STUD At ENE) OF SHEAR WALLS WALLS S HOLDOWNS. SEE SHEAR 3Z4" SHEATHING a NAIL w/ (2) ROWS ad 3" O.C. At S HOLDOUNS. SEE SHEAR WALL WALL SCHEDULE FOR 3x STUDS. ANCHOR BOLL w/ 3"x3"x�/4" (2) 2x CRIPPLE ;; PANEL EDGES. S SCHEDULE FOR 3x STUDS. WASHER SEE SCHEDULE FOR STUDS. SHEATHING NAILING PER SHEATHING S NAILING PER i.; PLAN OR SCHEDULE PLAN. SPLICE TO OCCUR SIZE S SPACING -USE Ns"4 AT a(2) 2x PLATE. (NAIL 60 O.C. U.N.O.ai� ON COMMON MEMBER 2x Pt SILL *'�;� SNt G TO EA PLATE) 4" SLAB ON GRADE OVER MIN. 6 MIL VAPOR BARRIER OR BLOCKING. _ is TOP OF STEM WALL I ° AS 6 MIN. INOt S.O.) *4 AR - NORIZ. �,c ELEV. VARIES FINISH GRADE OR rI cJl SLAB ON GRADE ji FINISH GRADE 12" MAX. j STHD HOLDOUN PER PLAN. j 2x Pt SILL STND HOEDOWN - 2x PT SILL w/ ANCHOR BOLL (S.O SfM.) 11 _ STHD14 HOLDOWN UNO. 5s"� ANCHOR BOLL w/ MIN. ER PLAN a S 3 x 3 x i4 WASHER PER 4 � BAR � 24 O.C. VERt. i2)EMBEDMENt S 3" x 3" x �i4" 1'-6" PLAN OR SCHEDULE. USE 5�$"0 a 60" O.C. MIN. 1'-6" MIN MIN. a, 4'- " MAX, GALVANIZED 1E WASHER 0 A •4 BAR CONTINUOUS MINNS FOUNDATION STEM WALL w/ a R PLAN. *4 MBAR 24" O.C. -VERTICAL 8�� D "I ' o ° 4 BAR HORIZ. TOP S BOTTOM. 04 A CONT. O � ° BAR 12 PORTAL FRAME PANEL LS(TYP.) 8" S2 0 SCALE: NONE I'-4" I'-4" 5 2 13 FOUNDATION ,AT 5L,45 ON GRADE FOUNDATION ,AT CRAWL 5PACE S o SCALE: I" = I'-0" S20 SCALE: I" = I'-0" GoPi'RIGHT 2020, SFGA FNe1NFFR5 JOB 10-09-1