Loading...
VS 22 Energy Calcs Plan APrescriptive Path Single Family 2018WashingtonStateEnergyCode-R 1 45Daylightw/ADU Prescriptive Path Single Family 2018WashingtonStateEnergyCode-R 2 Efficient Building Envelope Prescriptive Path Single Family 2018WashingtonStateEnergyCode-R 3 Please print only pages 1 through 3 of this worksheet for submission to your building official. 3.0 CLEAR FORM Simple Heating System Size: Washington State Project Information Contact Information Heating System Type: To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (∆T)41 ∆T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft)1,440 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft)8.5 12,240 Glazing and Doors U-Factor X Area =UA Instructions 0.280 191 53.48 Skylights U-Factor X Area =UA Instructions 0.50 --- Insulation Attic U-Factor X Area =UA Instructions 0.026 789 20.51 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No selection --- Above Grade Walls (see Figure 1)U-Factor X Area UA Instructions 0.056 1,806 101.14 Floors U-Factor X Area UA Instructions 0.025 789 19.73 Below Grade Walls (see Figure 1)U-Factor X Area UA Instructions No selection --- Slab Below Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Slab on Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Location of Ducts Instructions Duct Leakage Coefficient 1.10 Sum of UA 194.86 Envelope Heat Load 7,989 Btu / Hour Sum of UA x ∆T Air Leakage Heat Load 5,420 Btu / Hour Volume x 0.6 x ∆T x 0.018 Building Design Heat Load 13,409 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 14,750 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 18,437 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. 45 Daylight w / ADU Plan A Above Grade Below Grade Figure 1. All Other Systems Heat Pump (07/01/13) Window, Skylight and Door Schedule Project Information Contact Information Width Height Ref.U-factor Qt.Feet Inch Feet Inch Area UA Exempt Swinging Door (24 sq. ft. max.)0.0 0.00 0.0 0.00 Vertical Fenestration (Windows and doors) Component Width Height Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA 0.28 1 1 0 4 6 4.5 1.26 0.28 1 3 0 6 8 20.0 5.60 0.28 1 2 8 6 8 17.8 4.98 0.28 1 5 0 2 0 10.0 2.80 0.28 2 2 0 2 0 8.0 2.24 0.28 2 4 6 5 0 45.0 12.60 0.28 1 4 0 4 0 16.0 4.48 0.28 1 3 0 4 0 12.0 3.36 0.28 1 2 8 6 8 17.8 4.98 0.28 1 4 0 4 0 16.0 4.48 0.28 1 6 0 4 0 24.0 6.72 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.28 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 45 Daylight w / ADU Plan A entry entry door garage man door entry great rm great rm kitchen bedrm 2 man door bedrm 3 bedrm 1 Exempt Glazed Fenestration (15 sq. ft. max.) 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Vertical Fenestration Area and UA 191.1 53.50 Vertical Fenestration Area Weighted U = UA/Area 0.28 Overhead Glazing (Skylights) Component Width Height Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Overhead Glazing Area and UA 0.0 0.00 Overhead Glazing Area Weighted U = UA/Area 0.00 191.1 53.50Total Sum of Fenestration Area and UA (for heating system sizing calculations)