Loading...
Energy Code Worksheet2018 Washington State Energy Code — Residential Enerev Code Comoliance for All Climate Zones in These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings (townhouses). Project Information Contact Information LS2-2394 Instructions: This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings: Table R402.1- Insulation and Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits. (Authorized Representative Date All Climate Zones (Table R402.1.1) R-Value a U-Factor a Fenestration U-Factor b n/a 0.30 Skylight U-Factor° n/a _ 0.50 ;Glazed Fenestration SHGC bje n/a n/a Ceiling E 49 I 0.026 Wood Frame Wail g,h 211nt 0.056 Floor 30 0.029 Below Grade Wail `-h 10/15/21 int +TB 0.042 Slab ".r R-Value & Depth 10, 2 ft n/a ! R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less a than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. 10/15/21 +5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1. For single rafter- orjoist-vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth ke extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for g climate zone S of ICC 400. Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center, 78% of the wall cavity insulated and headers Insulated with a minimum of R-10 insulation. Prescriptive Path —Single Family 2018 Washington State Energy Cade-R 2018 Washington State Energy Code - Residential Enerev Code Camnliance for All Climate Zones in Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit: 6 credits All dwelling units that are not included in #1 or #3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details In Table 406.3 (Single Family), on page 4. Summary of Table R406.2 Heating Options Fuel Normalization Descriptions Credits - select ONE heating option User Notes 1 heating minimum NAECA° 0.0 ❑ __Combustion 2 Heatpump` _ 1.0 - l 3 Electric resistance heat only - furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 - 0.5 ❑ 5 All other heating systems -1.0 ❑ Energy I 'Options Energy Credit Option Descriptions Credits - select ONE energy option from each cate ory d 1.1 Efficient Building Envelope 0.5 ❑ 1.2 Efficient Building Envelope 1.0 ❑ 1.3 Efficient Building Envelope 0.5 1.4 Efficient Building Envelope 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope 0.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 ED 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ _ 2.3 Air Leakage Control and Efficient Ventilation _ 1.5 _ ❑ �2 4 Air Leakage Control and Efficient Ventilation 2.0 ❑ ._„ 3. la High Efficiency HVAC 1.0 ❑ 3.2 High Efficiency HVAC 1.0 El 3.3- High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC 1.5 _ ❑ 3.5 _ High Efficiency HVAC 1.5 ❑ High Efficiency HVAC 2.0 ❑ _3.60 4.1 High Efficiency HVAC Distribution System 0.5 __ _ ❑ 4.2 High Efficiency HVAC Distribution System 1.0 0 Prescriptive Path -Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code — Residential Prescriptive EnerRY Code Compliance for All Climate Zones in Was Summary of Table R406.2 (cant.) Energy Options Energy Credit Option Descriptions (cont.) Credits - select ONE energy option from each c_ategor User Notes 5.1d _ 5.2 _Efficient Water Heating Efficient Water Heating 0.5 0.5 ❑ ❑ 5.3 Efficient Water Heating 1.0 ___ ❑ 5.4 _ Efficient Water Heating 1.5 ❑ 5.5 _ Efficient Water Heating _ 2.0 ❑ 5.16 Efficient Water Heating _ 2.5 ❑ 6.1e Renewable Electric Energy(3 credits max) 1.0 7.1 1 Appliance Package Total Credits 0.5 ❑ 6.0 CLEAR FORM a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) c. Equipment listed in Table C403.3.2(1) or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may be combined with options 5.2 through 5.6. See Table 406.3, e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. Please�print only pages 1 through'3 of this worksheet for submission to your building,oElal. Prescriptive Path —Single Family 2018 Washington State Energy Code-R Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington Slate Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -dooms and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Healing System Type: Owi other systems OO ueet Pomp To see detailed instructions for each section, place yourcursoron the word "Instructions" Design Temperature msvuctions --- - - Design Temperature Difference (AT) Auburn AT= foucoriro degrees) -owdp rp sign Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 2,3841 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (it) :............ 8.5 20,349 Glazing and Doors U-Factor X Area - UA Instructions - u-o.aa 0.280 357 99.96 Skylights U-Factor X Area UA lastructions 0.50 --- Insulation Attic U-Factor X Area UA Instructions a-aa Gas 1 0.026 1.434' '. 37.28 Single Rafter or Joist Vaulted Collings U-Factor X Area UA Instructions "'ceiec[awalce No selection -_ Above Grade Walls (see Figure g U-Factor X Area UA Instructions 21 �ntermedate a ® 0.056 2,412 135.07 Floors U-Factor X Area UA Instructions j -"� 0.025 397. 9.93 n.3B� � Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions eeledil-4ve I®� No selection Slab Below Grade fsee Figure11 ___ _______ __ _ F-Factor X Length UA Instructions 6p5e'ect fwid�e'wing .... ..... 61 ®;;+ No selection --- Slab on Grade fsee Fisure 1) F-Factor X Length UA Instructions SelectR-value _ No selection 128: Location of Ducts Instructions Duct Leakage Coefficient CaidAWnEd Space 1.00 Sum of UA 282.24 Figure 1. AweGrade 45 Envelope Heat Load 12,701 Btu/Hour Sum of UAx AT Air Leakage Heat Load 9,890 Btu/Hour Volumex O,6xATx0.018 Building Design Heat Load 22,590 Btu / Hour Airleakaim + envelope heat loss Building and Duct Heat Load 22,590 Btu/Hour Ducts in unconditioned space: sum of buildfnp heat loss x 1.10 Ducts In conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 28,238 Btu/Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss 1.25 for heat pump (W101113) Window, Skylight and Door Schedule Project Information LS2 2894 Exempt Swinging Door (24 sq. ft. max.) Exempt Glazed Fenestration (15 sq. ft. max.) Vertical Fenestration (Windows and doors) Component Ref. U-factor ina�•�rinw Contact Information i I Width Height Qt. Feet inch Feet Inch Width Height Qt. Feet inch Feet inch Area UA Area UA 1 1 1 :1 11 111 1 1 1 1 1 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 1 1 1 it 11 111 Overhead Glazing (Skylights) Component Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area Width Height Sum of Overhead Glazing Area and UA Overhead Glazing Area Weighted U = UA/Area Total Sum of Fenestration Area and UA (for heating system sizing calculations) 11 111 11 111 11 111 11 111 11 111 3E 94.82 0.27 Area UA 11 111 11 111 1 1....... 1 11 1 I 111 11 111 1 11 356.3 94.82